Slack Span Dead-end GENERAL RECOMMENDATIONS NOMENCLATURE (440)

Similar documents
Armor Rods. Armor Rods NOMENCLATURE GENERAL RECOMMENDATIONS

ARMOR-GRIP Suspension: Double

TRANSMISSION LINE REPAIR MANUAL. A guidebook for the inspection and repair of damaged or worn conductors

Conductor Protection. results

THERMOLIGN Products for 3M Aluminum Conductor Composite Reinforced (3M ACCR)

Polymer Insulators A Better Solution

PLP Compression Dead-end & Jumper Terminal for ACSR & ACSS Conductors

August THERMOLIGN Products for CTC ACCC Conductor

COYOTE LCC (Low Count Closure)

Standard Compression Dead End for ACSR and ACSS Conductor CAUTION: ACSR Dead Ends Cannot Be Used on ACSS HT Conductor

Section 5 Fiber Optics: FIBERLIGN Hardware for OPGW

Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance

Section 6 FIBERLIGN Hardware for ADSS

Wire Management Products Index

COYOTE 9.5" x 19" (292 mm x 509 mm) Cross-Connect Dome Closure

INSULIGN Guy Strain Insulators Fiberglass

MARCH COYOTE 9.5 x 19 (292 mm x 509 mm) Terminal Dome Closure Kits

COYOTE Terminal Dome Closure 6.5" x 22"

VORTXô VIBRATION DAMPER

Jumper Terminals and Tee Taps. delivery

FIBERLIGN Suspension for OPGW

COYOTE CLOSURE ADOBE SERIES FOR UNDERGROUND, AERIAL, AND BURIED SPLICES 6.0" x 22" 8.5" x 22" (152.4 mm x mm mm x 558.

Aluminum Conductor Composite Reinforced Installation Guidelines and Maintenance

SPIRAL VIBRATION DAMPERS FOR AAC, AAAC, ACSR, COPPER, SC/AC & SC/GZ CONDUCTORS. Part Number

COYOTE 9.5" x 19" (292 mm x 509 mm) Dome Closure

EXCLUSIVE AUSTRALIAN DISTRIBUTORS

COYOTE 28" GLC (Ground Level Closure) Complete Assembly Installation

Convertible - Rated 3 4-Ton /2-Ton Nylon Strap Hoists Refer to any questions about the use, application, repair or testing of this hoist to:

GSA Series Formed Wire Suspension

Wildlife Protection Products. Jerry Liguori

Be sure to read and completely understand this procedure before applying product. Be sure to select the proper PREFORMED product before application.

SUSPENSION 04 CLAMPS

Section 4 - Protection

3M Cold Shrink QT-lll Silicone Rubber Skirted Termination Kit 7692-S-4, 7693-S-4, 7694-S-4, 7695-S-4, 7696-S-4

Wildlife Protection Products

JANUARY 2015 NOMENCLATURE. TOOLS REQUIRED 3/8" & 7/16" Can wrench or socket 1/4 Nut driver or screwdriver Snips Fiber optic cable opening tools

Wildlife Protection Products

MATERIAL FOR FIBRE OPTIC LINES. General C-bracket HSU trunnion type, forged, for aluminium based OPGW conductors...

COYOTE Dome Closure 6.5" x 22" Kits. COYOTE Dome Closure 6.5" x 22" for Buffer Tube Applications. Includes: (2) Grommets, (1) Buffer

3M Cold Shrink QT-III Silicone Rubber Termination

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-TOW/WOT

EARTH WIRE FITTINGS 08

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8-Tape/LC

JUMPERS & SWITCHING TOOLS

Suspension Clamps. performance

3M Cold Shrink QT-III Silicone Rubber Indoor Termination Kits With High-K Stress Relief

Tests are conducted in accordance with IEEE Standard 386. ac 60 Hz 1 Minute Withstand 50

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

COYOTE Dome Cross-Connect Closure 6-1/2" x 22"

A. General: Deliver, store and handle wire and cable in accordance with the manufacturer's instructions and as specified in Division 1.

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TOW/WOT (RW)

3M Cold Shrink Silicone Rubber Skirted Termination Kit QT-III 7672-S-8-TS (RW)

DISTRIBUTION catalogue

Cold Shrink Silicone Rubber Termination QT-III (With High-K Stress Relief)

Compression Hardware Series For ACSR Conductors

Introduction. Nexans wire and cable. Contact us for all your wire and cable needs

DISTRIBUTION PRODUCTS

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

3M Cold Shrink QT-lll Silicone Rubber Indoor Tubular Termination Kits With High-K Stress Relief

ELB ELB

COYOTE STP (Service Termination Point)

copper stud. If a 900 A rating is desired, specify a C as the 8th digit when determining your part number (See Table 3, page 3.)


Jumpers & Load Pickup Tools

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Aluminum and Steel Liquidtight Strain Relief Cord and Cable Connectors

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kits

CONTENTS. This Product is Certified by CANADIAN STANDARDS ASSOCIATION and Bears the Mark:

3M Cold Shrink QT-III Silicone Rubber Indoor Tubular Termination Kit

SECTION 3 - PRIMARY CONSTRUCTION OVERHEAD TABLE OF CONTENTS

600 A 35 kv class separable splices

Cold Shrink Silicone Rubber Termination QT-III 7672-S-8-JCN

Cam-Lok Single Pole Connectors

TC-RHH/RHW-2 USE-2 Copper

Kellems Wire Management Products

High Voltage Copper, Smooth Aluminum Shield/Sheath

Features and Benefits

Cold Shrink QS T Trifurcating Transition Splice Kit

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit With High-K Stress Relief

TC-THHN/THWN-2 Copper, PVC/Nylon Insulated

Index Section 103 Joint Use. General Requirements for Installation of Attachments on Oncor Poles

COYOTE STP (Service Termination Point)

Impact, Torsion, and Crush Tests for 477 kcmil and 795 kcmil 3M Brand Composite Conductor. 3M Company Purchase Order

DRILL CORD. Insulation Nominal Size. Approximate Amps Anixter. Number Number Thickness O.D.

ELB ES. Product Installation Instructions

Company Profile. ZTT Cable was established in 1992, and now becomes a public high-tech enterprise with 33 subsidiaries, and about 7,000 employees.

Loadbreak Elbows. 3 Loadbreak Elbows. 200 Amp 5-15 kv Industrial pg Loadbreak Elbows. 200 Amp 25 kv Industrial pg. 254.

3M Cold Shrink QT-III Silicone Rubber Skirted Termination Kit

TEMPORARY ELECTRIC WIRING FOR CARNIVALS, CONVENTIONS, EXHIBITIONS, FAIRS AND SIMILAR USES

3M Cold Shrink Silicone Rubber Outdoor Termination Kit QT-III 7600-S-3W Series

TC-XHHW-2 Copper, XLPE Insulated, PVC Jacketed

3M Brand Composite Conductor Connector Current Cycle Qualification Test for 795 kcmil Compression Connectors

3M Cold Shrink QT-III Silicone Rubber Termination 7673-S-8(S)-JCN

3M Cold Shrink 1/C Transition Splice Kit QS-III, 5510A-1T-PILC Series

AMENDMENT ELECTRIC SERVICE MANUAL 2014

TENSION CLAMPS AND JOINTS. General Wedge tension clamp without jumper guide, for aluminium based conductors... 79

POWER. Lengths (ft) Nominal Overall Diameter. Part Number. Gauge /strands

VORTX Vibration Damper

OPERATION SERVICE PARTS TUGIT2. Manually Operated Short Handle Lever Hoist A3140-XXX

High Voltage Aluminum, Smooth Aluminum Shield/Sheath

Transcription:

NOMENCLATURE Material Helical Leg Section: Aluminum covered steel. An aluminum alloy version is available for corrosive environment. Contact PLP. Crossover Marks: Indicates starting point for application on conductor. Color Code & Length: Assists in identification of conductor diameter range, corresponding to tabular information listed on catalog pages. Covered Loop Section: Elastomeric compound specifically formulated for resistance to ozone attack, weathering and abrasion. Product Identification Tag/Warning Label: Identifies catalog number, appropriate conductor types and sizes and product usage limitations. GENERAL RECOMMENDATIONS is intended for use on aluminum based conductors with diameter ranges from.229" to 1.216". It is specifically designed to terminate primary, secondary and neutral conductors. Each covers a range of conductor diameters as outlined on catalog pages. Conductor Tension Limitations: The is specifically designed for LIMITED TENSION APPLICATIONS. IT SHOULD NOT BE USED AS A FULL TENSION DEAD-END. The is intended for use where guying (or other) restrictions prevent full tension spans. While individual utility construction and safety practices should dictate actual installations, each has a warning label attached suggesting a maximum allowable loaded tension of 1000 lbs. This value does not indicate a holding strength rating for s; rather, it suggests a practical limit for tensions in this type of construction. The replaces conventional ing equipment used in slack span construction. insulators, clamps, and associated hardware when used in this way normally do not offer tight, solid electrical connections between each other. This looseness can allow intermittent contact and ultimately produce troublesome RFI (RIV) and TVI. Construction practices utilizing the can minimize this problem. The is specifically designed to be installed on pin, line post or spool insulators when used in limited tension construction. Refer to Figure 1 for a typical installation. Refer to Illustrations 1 and 2 and Acceptable Fitting Section for acceptable types and sizes of insulators and fittings. Covered Loop Section: The loop of the is covered with an elastomer to provide protection against abrasion and damage to the glaze of the insulator. It also helps minimize RFI, TVI, etc. The is designed to grip the conductor uniformly to prevent distortion. It also offers a unique design that eliminates bolts, nuts, washers and other component parts that may become lost or damaged during installation or in service. Where requirements call for increased tension applications, use either the Distribution Grip or the Overhead Deadend. On jacketed conductors, use either Coated s or Distribution Grip s. Where requirements call for ing conductors associated with bare neutral messengers or self-supporting cable used in making service drops, use Service Grip s. Distribution Grip (/Overhead) Dead Ends are not recommended for use with high temperature/low sag conductors such as ACSS, ACSS/AW, ACSS/TW, ACCR or other types of conductors with loose, and/or annealed outer layer strands. Typically THERMOLIGN Dead Ends are suggested for these applications; consult PLP for further information. -23

INSTALLATION GUIDELINES Conductor Compatibility: s should be used only on the size and type of conductor for which they are designed. They must have the same lay as the conductor to which they are being applied. When ordering s, make sure to specify the conductor size and type they are to be used on. When using types and/or sizes of conductors not mentioned in these catalog pages, consult Preformed Line Products Company. During installation, and at all times, care should be taken to avoid gouging or damaging the protective coating of the or the conductor itself. s should not be used as tools; i.e., come-alongs, pulling-in grips, etc. Tools are not required to install s, except for hot stick applications. Tapping: Tapping over the legs of the is NOT recommended. Taps can be made beyond the ends of the on the conductor or on the conductor tail that extends through the loop. s should not be used on overhead shield wires. FOR ADDITIONAL INFORMATION REGARDING INSTAL- LATION, REFER TO THE APPLICA- TION PROCEDURE. When in doubt about dimensions, fittings, installations, or unusual applications, consult your PREFORMED Sales Representative or Preformed Line Products Company. ACCEPTABLE FITTINGS s are specifically designed to be applied around the necks of certain pin, line post and spool insulators. s can be applied to either: a. ANSI C and F neck insulators and ANSI class 53-1 to 53-5 spool insulators, or b. ANSI J neck insulators. Refer to Illustration 1. for nominal insulator neck sizes and appropriate size. Application of s to non-insulator fittings is acceptable as long as the fitting: a. has smoothly contoured dimensions, b. has a seat diameter (Illustration 2, Figure 1) consistent with the insulator neck diameters shown in Illustration 1., c. has a minimum groove width (Illustration 2, Figure 2) of 9/16". SAFETY CONSIDERATIONS 1. This product is intended for a single (one-time) use and for the specified application, although it may be reapplied twice for retensioning within 90 days of initial installation. CAU- TION: DO NOT MODIFY OR REUSE THIS PRODUCT AFTER 90 DAYS UNDER ANY CIRCUMSTANCES. 2. This product is intended for use by trained craftspeople only. This product SHOULD NOT BE USED by anyone who is not familiar with and trained in the use of it. 3. When working in the area of energized lines with this product, EXTRA CARE should be taken to prevent accidental electrical contact. 4. For PROPER PERFORMANCE AND PERSONAL SAFETY be sure to select the proper size PREFORMED product before application. 5. PREFORMED products are precision devices. To insure proper performance, they should be stored in cartons under cover and handled carefully. -24

Illustration 1. Applicable Pin, Line post and Spool Insulators Illustration 2. Acceptable Dimensions for Non-Insulator Fittings -25

For use on: ACAR, All-Aluminum ACSR, Aluminum Alloy AWAC, Compacted ACSR C-Neck and F-Neck Interchangeable Headstyle Insulators: 2-1/4" Neck Diameter 2-7/8" Neck Diameter ANSI Class Spool Insulators: ANSI 53-1, 53-2, 53-3 1-3/4" Neck Diameter ANSI 53-4, 53-5 2-7/8" Neck Diameter Conductor Per Carton Catalog Number Range (Inches) Nominal Size Units Length (Inches) Color Code SSDE-9122.229-.257 #4 AWG 25 16 Orange SSDE-9124.290-.325 #2 AWG 25 18 Red SSDE-9125.326-.364 #1 AWG 25 19 Green SSDE-9126.365-.409 1/0 AWG 25 20 Yellow SSDE-9127.410-.460 2/0 AWG 25 18 Blue SSDE-9128.461-.516 3/0 AWG 25 18 Orange SSDE-9129.517-.577 4/0 AWG 25 19 Red SSDE-90.578-.665 266.8 kcmil 25 21 Black SSDE-91.666-.783 336.4 kcmil 25 21 Green SSDE-92.784-.883 477 kcmil 25 22 Orange SSDE-93.884-1.025 636 kcmil 25 25 Brown SSDE-94 1.026-1.216 795 kcmil 25 26 Orange Right-hand lay standard EXPLANATORY NOTES: (1) AWAC is a registered trademark of the Copperweld Co. (2) Where ing requirements call for other than limited tension requirements, refer to Distribution-Grip s, -Coated, or Overhead. (3) Where ing requirements call for Service Grip s, refer to that section. (4) Insulators with C and F neck dimensions can be identified by consulting the manufacturer. (5) Conductor Range indicates the range of conductors that utilize the same. (6) Refer to Illustrations 1 and 2 and Acceptable fittings portion of this section for dimensions of appropriate insulators and fittings. (7) When in doubt about dimensions, insulators, fittings, installations, or unusual applications, consult your PREFORMED sales representative or Preformed Line Products Co. -26

For use on: ACAR, All-Aluminum ACSR, Aluminum Alloy AWAC, Compacted ACSR J-Neck Interchangeable Headstyle Insulators: 3-1/2" Neck Diameter ANSI 55-6 Single Skirt Pin ANSI 55-7 Single Skirt Pin ANSI 55-8 Double Skirt Pin Conductor Per Carton Catalog Number Range (Inches) Nominal Size Units Length (Inches) Color Code SSDE-9142.229-.357 #4 AWG 25 18 Orange SSDE-9144.290-.325 #2 AWG 25 19 Red SSDE-9145.326-.364 #1 AWG 25 20 Green SSDE-9146.365-.409 1/0 AWG 25 21 Yellow SSDE-9147.410-.460 2/0 AWG 25 19 Blue SSDE-9148.461-.516 3/0 AWG 25 20 Orange SSDE-9149.517-.577 4/0 AWG 25 21 Red SSDE-9150.578-.665 266.8 kcmil 25 22 Black SSDE-9151.666-.783 336.4 kcmil 25 23 Green SSDE-9152.784-.883 477 kcmil 25 24 Orange SSDE-9153.884-1.025 636 kcmil 25 27 Brown SSDE-9154 1.026-1.216 795 kcmil 25 28 Orange Right-hand lay standard EXPLANATORY NOTES: (1) AWAC is a registered trademark of the Copperweld Co. (2) Where ing requirements call for other than limited tension requirements, refer to Distribution Grip s, Deadend-Coated, or Overhead. (3) Where ing requirements call for Service Grip s, refer to that section. (4) Insulators with C and F neck dimensions can be identified by consulting the manufacturer. (5) Conductor Range indicates the range of conductors that utilize the same. (6) Refer to Illustrations 1 and 2 and Acceptable fittings portion of this section for dimensions of appropriate insulators and fittings. (7) When in doubt about dimensions, insulators, fittings, installations, or unusual applications, consult your PREFORMED sales representative or Preformed Line Products Co. -27