GRUNDFOS PRODUCT GUIDE LM, LP. Single-stage close coupled in-line circulating pumps 60 Hz

Similar documents
GRUNDFOS PRODUCT GUIDE CH, CHN. Horizontal multistage end-suction pumps

GRUNDFOS PRODUCT GUIDE. VersaFlo. TP circulator pumps 60 Hz

GRUNDFOS DATA BOOKLET. Fire CRFF. Grundfos fire systems. VdS-approved CR pumps for fire systems 50 Hz

Contents. General data. Technical data, SPK/CRK. General data, MTA(D) Technical data, MTA(D) General data, MTR. General data, MTC

Renewable Solar Inverter, RSI

GRUNDFOS DATA BOOKLET. Self-priming. 50/60 Hz

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

Renewable Solar Inverter, RSI

GRUNDFOS PRODUCT GUIDE CRT, CRTE. Vertical multistage centrifugal pumps in titanium 60 Hz

CR30 CR60 (Model B) CR

GRUNDFOS GROUNDWATER SERVICE MANUAL 300S. Parts List Submersibles. Contents Parts List Special Tools Standard Tools Part Dimensions

GRUNDFOS GROUNDWATER SERVICE MANUAL 230S. Parts List Submersibles. Contents Parts List Special Tools Standard Tools Part Dimensions

Grundfos solar surface pump

GROUNDWATER PRODUCTS

GRUNDFOS PRODUCT GUIDE SQ, SQE, SQE-NE, CU 321

Grundfos.bk Page 1 Thursday, June 11, :59 PM GRUNDFOS INSTRUCTIONS. CRN MAGdrive. Installation and operating instructions

Grundfos solar surface pump

SQFlex battery back-up system

DPS. The SSV Dual Pump System

Motors " GRUNDFOS GROUNDWATER SERVICE MANUAL CONTENTS. Grundfos Motor Specifications... Page 2

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

GRUNDFOS DOSING SYSTEMS

SL1, SLV Pumps GRUNDFOS PRICE BOOK

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

Lenntech GRUNDFOS DATA BOOKLET. CME 15. Horizontal, multistage centrifugal pumps 50/60 Hz

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ

Latest edition? Sources of product documentation. WebGOLD. WinCAPS. WebCAPS

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ

1SV (e-sv) 60 Hz 3500 RPM

GRUNDFOS PRODUCT GUIDE. SQFlex. Renewable-energy based water-supply systems 50/60 Hz

TP /4-A-F-A-BUBE 400Y 50HZ

Grundfos MAGNA, Relay Module

GRUNDFOS VERSAFLO up(s) THE QUIET REVOLUTION. Grundfos VersaFlo UP(S) Wet Rotor Circulators

CMBE Booster. Lenntech. Description 50/60 Hz. Horizontal, multistage centrifugal boosters

CRI3-6 A-FGJ-I-E-HQQE 3x230/400 50HZ

1SV (e-sv) 50 Hz 2900 RPM

grundfos smartflo SmartFlo System Sizing Pocket Guide Curves and sizing information for all SmartFlo systems

RSV Series In-Line Vertical Multi-Stage, Ring Section Pump September 2013

CR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ

GRUNDFOS Commer CR1. Parts List & Kits. Contents. Parts List Spare Part Kits Accessories Special Tools Standard Tools Tools for Torques

CRI5. Parts List & Kits. GRUNDFOS Industrial Service Manual. Contents

CR3-19 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR10-02 A-A-A-E-HQQE 3x230/ HZ

CRI1-6 A-P-I-E-HQQE 3x230/400 50HZ

CR3-10 A-A-A-E-HQQE 3x230/400 50HZ

GRUNDFOS Commer CR3. Parts List & Kits. Contents. Parts List Spare Part Kits Accessories Special Tools Standard Tools Tools for Torques

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

CRN3-3 A-FGJ-G-V-HQQV 3x230/400 50HZ

CR15-02 A-F-A-E-HQQE 3x400D 50 HZ

TP /2-A-F-A-BUBE 1X230 50HZ

CR10-04 A-A-A-E-HQQE 15kW 3x400Y 50Hz

GRUNDFOS CR SERVICE MANUAL CR5. Parts List & Kits. Contents. Parts List Spare Part Kits Accessories Special Tools Standard Tools Tools for Torques

CR5-16 A-A-A-E-HQQE 3x400D 50HZ

Contents. Identification

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CR45-10 A-F-A-E-HQQE 3x400/ HZ

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CRN3-6 A-P-G-V-HQQV 3x230/400 50HZ

EVMU. Model EVMU / EVMUG / EVMUL Contents. EBARA Stainless Steel Vertical Multistage

TP /4-A-F-A-BQQE 400Y 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

GRUNDFOS CR SERVICE MANUAL CR3. Parts List & Kits. Contents. Parts List Spare Part Kits Accessories Special Tools Standard Tools Tools for Torques

CRN20-02 A-FGJ-G-E-HQQE 3x400D 50 HZ

Grundfos Home Booster

GRUNDFOS DATA BOOKLET. Hydro Multi-B. Booster systems with 2 or 3 pumps 60 Hz. Drinking Water System Component NSF / ANSI 61 NSF / ANSI 372

CR A-F-A-E-HQQE 3x400/ HZ

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

VERTICAL MULTI-STAGE PUMPS

VERTICAL MULTI-STAGE PUMPS

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

NB /193 A-F2-A-BAQE

CRN5-7 A-P-G-E-HQQE 3x230/400 50HZ

TECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

CR10-10 A-A-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

GRUNDFOS WHITE PAPER. Parallel Pumping by Steve Wilson WHAT IS PARALLEL PUMPING?

CRN3-25 A-P-G-E-HQQE 3x400D 50HZ

TP /2-A-F-A-BQQE 400D 50HZ

Hydro MPC-E 2CRIE L GNL

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

Latest edition? Sources of product documentation. WebGOLD. WinCAPS. WebCAPS

CR A-F-A-V-HBQV 3x400/ HZ

CRN15-01 A-P-G-V-HQQV 3x230/ HZ

TP /2-A-F-A-BAQE 400D 50HZ

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

GRUNDFOS CR SERVICE MANUAL CR1. Parts List & Kits. Contents. Parts List Spare Part Kits Accessories Special Tools Standard Tools Tools for Torques

CR A-F-A-V-HQQV 3x400/ HZ

ITT. Goulds Pumps. G&L Series SSH S & M-Group 316 Stainless Steel End Suction Pumps. Engineered for life. Commercial Water.

CRN1-27 A-P-G-V-HQQV 3x230/400 50HZ

GRUNDFOS DATA BOOKLET NS, PF. 50 Hz

NB /263 AS-F2-A-BAQE

CRN3-11 A-P-G-V-HQQV 11kW 3x400Y 50Hz

CR120-2 A-F-A-E-HQQE 3x400/ HZ

CRN45-5 A-F-G-V-HQQV 3x400/ HZ

Transcription:

GRUNDFOS PRODUCT GUIDE LM, LP Single-stage close coupled in-line circulating pumps 6 Hz

LM, LP Table of contents 1. Product introduction 3 Introduction 3 Applications 3 Features and benefits 3 Identification 4 4 2. Product overview 5 Performance range 5 3. Construction 6 LM, LP materials of construction 6 4. Operating conditions 6 LM, LP operating conditions 6 5. Selection 6 Pumped liquids 6 Selection of pumps 6 Ordering LM, LP pumps 6 6. Installation 7 Installation 7 7. 8 2.5 LM 5/XX 8 2.5 LM 6/XX 1 2.5 LM 8/XX 12 3. LM 5/XX 14 3. LM 6/XX 16 3. LM 8/XX 18 2.5 LP 5/XX 2 3. LP 5/XX 22 3. LP 6/XX 24 4. LP 5/XX 26 Electrical data, weights and dimensions 27 Technical data 27 LM 4 pole motor data 28 LP 2 pole motor data 28 8. Further product documentation 3 WebCAPS 3 WinCAPS 31 9. Submittal data sheet 33 2

LM, LP 1 1. Product introduction Introduction Grundfos LM and LP pumps are single-stage, close coupled, in-line pumps designed for reliability and performance. Pump LM, LP in-line pumps are vertical, single-stage centrifugal pumps of the non-self-priming type fitted with standard motors and mechanical shaft seals. Pumps with the same nominal flow rates have the same nominal port diameters (inches) and port to port length, irrespective of head and speed. Product introduction Fig. 1 Grundfos LM, LP Applications Grundfos LM and LP pumps are suitable for booster, circulation, transfer and water supply applications in: Boiler/hydronic heating chilled water air conditioning systems cooling towers washdown systems other industrial systems. Features and benefits Maintenance-free with a low starting torque and a high operating efficiency. Direct-coupled to standard NEMA C-face motors for easy installation. High quality 431stainless steel pump shaft. Stainless steel impeller. High grade stainless steel pump shaft, neck ring, and impeller are designed for years of maintenance-free operation. Corrosion-resistant carbon/tungsten carbide shaft seal faces provide reliable performance in open or closed systems. Optional types of shaft seals are available for various liquid, temperature, and pressure requirements. TM4 9719 51 Motor stool The motor stool forms the connection between pump housing and motor and is equipped with a manual air vent for the venting of pump housing and shaft seal chamber. The motor side flange of the motor stool is according to NEMA. Pump housing Pumps feature in-line, spiral-shaped cast iron pump housing with flange dimensions to ANSI. The dimensions of the suction and discharge ports are identical. Both pump flanges have pressure gauge tappings. A drain plug is fitted in the bottom of the pump housing. Base plates for the LM and LP pumps are available on request. Impeller The LM and LP impellers are made of stainless steel with double curved blades and smooth surfaces to ensure a hydraulically correct shape of the impeller. The impellers are machined to attain high accuracy of dimensions and to ensure good balance. When seen from the motor fan the direction of rotation is as follows: LM, LP:Counter-clockwise. Motor Baldor TEFC motors in NEMA C-face frame sizes are standard. ODP and special duty classes are optional. Motors are rated: The motor must be connected to a motor starter in accordance with local regulations. 3

1 LM, LP Product introduction Shaft seals The pumps are fitted as standard with a single, unbalanced carbon/tungsten carbide rubber bellows shaft seal in either a 16 mm or 22 mm diameter size with EPDM elastomer (BUBE). Optional shaft seals are also available: Unbalanced carbon/tungsten carbide rubber bellows shaft seal in either a 16 mm or a 22 mm diameter size with FKM elastomer (BUBV). Unbalanced tungsten carbide/tungsten carbide O-ring shaft seal in either a 16 mm or 22 mm diameter size with EPDM elastomer (AUUE). And for glycol/water mixtures: unbalanced reduced-face tungsten carbide/tungsten carbide, O-ring shaft seal in either a 16 mm or 22 mm diameter size with both EPDM and FKM elastomers (RUUE/V). The circulation of liquid in the duct of the air vent screw ensures lubrication and cooling of the shaft seal. Identification Type key LM, LP Example 2.5 L M 5 / 4.6 U - G - A - BBUE Pipe connection size Pump range M = 4-pole motor P = 2-pole motor Nominal impeller diameter [inches] Actual impeller diameter [inches] Pump version U: NEMA version Connection type G: ANSI connection Material A: Basic version Shaft seal A: O-ring seal with fixed driver B: Rubber bellows seal R: O-ring seal, type A, with reduced seal faces B: Carbon U: Tungsten Carbide E: EPDM V: FKM 4

LM, LP 2 2. Product overview Performance range p [kpa] 6 5 4 H [ft] 2 15 3. LP 6 LM/LP 6 Hz Product overview 3 1 8 2.5 LP 5 3. LP 5 4. LP 5 2 6 2.5 LM 8 3. LM 8 4 2.5 LM 6 1 9 8 7 3 2.5 LM 5 3. LM 6 6 2 5 4 15 3. LM 5 3 1 2 3 4 6 8 1 15 2 3 4 6 8 Q [US GPM] 5 6 7 8 9 1 2 3 4 5 6 7 8 1 Q [m³/h] TM2 4976 192 Product range Pump type Flow [gpm] Head [ft] Ph Hp Flange Page 2.5 LM5/4.6 25-155 7-21 1, 3.75 2 1/2 ANSI 8-9 2.5LM5/5.2 25-18 15-3 1, 3 1.5 2 1/2 ANSI 8-9 2.5LM6/6.2 3-175 18-4 1, 3 2 2 1/2 ANSI 1-11 2.5LM6/6.9 3-185 33-54 1, 3 3 2 1/2 ANSI 1-11 2.5LM8/8. 45-23 38-66 1, 3 5 2 1/2 ANSI 12-13 3.LM5/4.6 65-265 6-18 1, 3 1 3 ANSI 14-15 3.LM5/5. 65-265 13-22 1, 3 1.5 3 ANSI 14-15 3.LM5/5.4 65-31 16-28 1, 3 2 3 ANSI 14-15 3.LM6/6.3 65-35 16-38 1, 3 3 3 ANSI 16-17 3.LM6/6.6 65-4 19-46 1, 3 5 3 ANSI 16-17 3.LM8/7.4 9-42 29-57 1, 3 5 3 ANSI 18-19 3.LM8/8.3 9-46 46-71 3 1 3 ANSI 18-19 2.5LP5/4.3 6-26 3-77 1, 3 5 2 1/2 ANSI 2-21 2.5LP5/4.6 6-28 36-85 1, 3 5 2 1/2 ANSI 2-21 2.5LP5/5. 6-3 46-12 1, 3 7.5 2 1/2 ANSI 2-21 3.LP5/4.9 45-35 59-95 1, 3 7.5 3 ANSI 22-23 3.LP5/5.2 45-37 73-114 1, 3 1 3 ANSI 22-23 3.LP6/5.6 65-31 55-14 3 15 3 ANSI 24-25 3.LP6/6.1 65-33 85-158 3 15 3 ANSI 24-25 3.LP6/6.6 65-35 1-18 3 2 3 ANSI 24-25 4.LP5/4.3 13-48 3-7 1, 3 7.5 4 ANSI 26-27 4.LP5/4.9 13-55 47-85 1, 3 1 4 ANSI 26-27 4.LP5/5.2 13-59 67-15 3 15 4 ANSI 26-27 4.LP5/5.5 13-63 84-124 3 2 4 ANSI 26-27 5

3 LM, LP Construction 3. Construction LM, LP materials of construction 3 2 6 9 7 Pos. Components Materials AISI/ ASTM 1 Motor stool Cast iron EN-GJL-25 2 Coupling guard Stainless steel 34 3 Coupling Cast iron EN-GJS-4-15U or sintered metal 4 Pump housing Cast iron EN-GJL-25 5 Air vent screw Brass 6 Shaft Stainless steel 431 7 Impeller Stainless steel 34 8 Neck ring Stainless steel 34 9 Mechanical seal Carbon/tungsten carbide 1 O-ring EPDM 4. Operating conditions LM, LP operating conditions 5 1 1 4 8 TM 12 2294 5. Selection Pumped liquids LM, LP pumps are suitable for pumping thin, clean, non-aggressive and non-explosive liquids without solid particles or fibers. EPDM rubber parts fitted as standard are primarily designed for water. When pumping other liquids than water or water containing mineral oil or chemicals, the rubber parts chosen must be suitable for the pumped liquid. Selection of pumps The standard concept of the motor selection for Grundfos in-line pumps is that the installed motor horsepower can cover the whole performance curve of the specified nominal impeller diameter, which means that it is only needed to check if the requested duty point is somewhere on the performance curve of the nominal impeller diameter which belongs to a certain standard installed motor horsepower. The power consumption which belongs to the duty point can be taken from the power curve shown in the performance curve of the pump. Ordering LM, LP pumps Requested data: Q in US gpm H in ft pump type motor Hp voltage and frequency liquid and liquid temperature. Liquid temperature: LM, LP: +5 F to +25 F. Maximum operating pressure: LM, LP: 175 psi (12 bar) Inlet pressure Minimum inlet pressure according to the NPSH curve. The maximum inlet pressure is limited by the maximum operating pressure. The inlet pressure plus the maximum boost pressure from the pump must always be lower than the maximum operating pressure. 6

LM, LP 6 6. Installation Installation The pump can be placed on a vibration-absorbing material. Vibration and noise from the pump can be further reduced by fitting anti-vibration mountings either side of the pump. Installation options Installation Top-pull-out design The pump head (motor, motor stool and impeller) can be removed without disruption to the pipework. The following minimum clearances must be allowed above the motor: Pumps fitted with motors up to and including 5 Hp require a 12 inch clearance above the motor. Pumps fitted with motors of 7.5 Hp and up require at least a 36-inch clearance above the motor to allow the use of lifting equipment, if required. Fig. 3 Direct mounting on a suction header (up to 7.5 Hp) TM 13 192 Connection The pump may be installed in horizontal or vertical pipework depending on the motor size. Mounting in an elastically supported vertical pipe (up to 7.5 Hp) Pumps fitted with motors up to and including 15 Hp may be installed with the motor/pump shaft in all positions between vertical and horizontal, but the motor must never fall below the horizontal plane. Pumps fitted with motors of 2 Hp and up should only be installed horizontally with the motor/pump shaft in vertical position. It is advisable to fit isolating valves either side of the pump to avoid draining the system if the pump needs to be cleaned or repaired. Installation positions The pump can be installed with the motor (motor center line) in all positions between vertical and horizontal. To avoid water penetration of the motor and bearings, the motor must never fall below the horizontal. Mounting in an elastically supported horizontal pipe (up to 7.5 Hp) Fig. 4 Options for mounting in piping TM 14 1293 TM2 433 45 Fig. 2 Allowable installation positions 7

7 LM, LP 7. 2.5 LM 5/XX H [m] H [ft] 1 4% 3 55% 65% 7% 8 25 73% 2.5 LM 5 6 Hz 175 RPM 7% 6 2 5% 6% 66% 6% 15 /5.2 4 1 55% 5% NPSH [ft] 1 4% 2 5 /4.6 5 NPSHR 2 4 6 8 1 12 14 16 Q [US GPM] 5 1 15 2 25 3 35 4 Q [m³/h] P2 [hp] 1.2 1..8.6.4.2. 2 4 6 8 1 12 14 16 Q [US GPM] /4.6 /5.2 TM2 4966 211 8

LM, LP 7 2.5 LM 5/XX 4 x Ø.63" Z B3 B4 D1 D2 D4 H3 H1 H2 L2 B1 B2 L1 2 x 21/4" x.25" NPT F D5 2 x Ø.69" ø11/16" 44 x x ø9/16" Ø.56" 2 x M16 x 1.125" 1 1/8" DP 7 7.69" 11/16" 9 9.25" 1/4" 1.38" 1 3/8" 5 " 11/16" 7 7.69" 11/16" 9.25" 1/4" TM2 4966 211 Electrical data, weights and dimensions Pump type Hp Mtr S.F. Ph NEMA Frame size Volts Dimensions [inches (mm)] D1 D4 D5 B1 B2 B3 B4 H1 H2 H3 L1 L2 Ship. wt. [lbs] 2.5 LM 5/4.6.75 2.5 LM 5/5.2 1.5 1.15 1 56C 115/23 1.25 3 56C 1.15 1 56C 1.15 3 56C 28-23/ 46, 575* 115/ 28-23 28-23/ 46, 575* 2.5 (64) 2.5 (64) 2.5 (64) 2.5 (64) 5.5 (14) 5.5 (14) 5.5 (14) 5.5 (14) 7. (178) 7. (178) 7. (178) 7. (178) 7.19 (183) 6.19 (157) 7.19 (183) 7.19 (183) 5.75 (146) 5.19 (132) 5.75 (146) 5.75 (146) 4.38 (111) 4.38 (111) 4.38 (111) 4.38 (111) 4.56 (116) 4.56 (116) 4.56 (116) 4.56 (116) 5.5 (14) 5.5 (14) 5.5 (14) 5.5 (14) 2.25 (514) 19.35 (492) 22.12 (562) 21.23 (539) 19. (483) 19. (483) 19. (483) 19. (483) 9.5 (241) 9.5 (241) 9.5 (241) 9.5 (241) 136 122 161 146 Technical data Nominal flow range Min. flow rate Head range Motors 25-18 U.S. gpm 15 U.S. gpm 7-3 ft TEFC (standard) / ODP (optional) Temp. range [ F ( C)] +5 to +25 (-15 to +121 ) Max. working pressure Flanges: 175 psi 2 1/2" ANSI 125 lb. F.F. *575V available on request. 9

7 LM, LP 2.5 LM 6/XX H [m] H [ft] 55 16 5 14 45 12 4 5% 6% 55% 65% 68% 65% 6% 2.5 LM 6 6 Hz 175 RPM 55% 1 35 3 63% /6.9 8 25 6 2 5% 4 15 1 /6.2 NPSH [ft] 1 2 5 NPSHR 2 4 6 8 1 12 14 16 Q [US GPM] 5 5 1 15 2 25 3 35 4 Q [m³/h] P2 [hp] 2.4 2. 1.6 1.2.8.4. 2 4 6 8 1 12 14 16 Q [US GPM] /6.2 /6.9 TM2 4967 211 1

LM, LP 7 2.5 LM 6/XX 4 x Ø.63" Z B3 B4 D1 D2 D4 H3 H1 H2 L2 B1 B2 L1 2 x 1/4".25" NPT F D5 2 x Ø.69" ø11/16" 44 x x ø9/16" Ø.56" 2 x M16 x 1.125" 1 1/8" DP 1.38" 1 3/8" 7 7.69" 11/16" 9 9.25" 1/4" 5 " 11/16" 7 7.69" 11/16" 99.25" 1/4" TM2 4964 211 Electrical data, weights and dimensions Pump type Hp Mtr S.F. Ph NEMA Frame size Volts Dimensions [inches (mm)] D1 D4 D5 B1 B2 B3 B4 H1 H2 H3 L1 L2 Ship. wt. [lbs] 2.5 LM 6/6.2 2 1.15 1 56C 115/23 3 56C 28-23/ 46, 575* 2.5 (64) 2.5 (64) 5.5 (14) 5.5 (14) 7. (178) 7. (178) 7.19 (183) 7.19 (183) 5.75 (146) 5.75 (146) 6.18 (157) 6.18 (157) 5.94 (151) 5.94 (151) 4.56 (126) 4.56 (126) 5.5 (14) 5.5 (14) 22.13 (562) 21.23 (539) 19. (483) 19. (483) 9.5 (241) 9.5 (241) 163 159 2.5 LM 6/6.9 3 1.15 1 182TC 115/23 3 182TC 28-23/ 46, 575* 2.5 (64) 2.5 (64) 5.5 (14) 5.5 (14) 7. (178) 7. (178) 7.19 (183) 7.19 (183) 5.75 (146) 5.75 (146) 6.18 (157) 6.18 (157) 5.94 (151) 5.94 (151) 4.56 (126) 4.56 (126) 6.6 (154) 6.6 (154) 24.3 (617) 24.3 (617) 19. (483) 19. (483) 9.5 (241) 9.5 (241) 22 18 Technical data Nominal flow range Min. flow rate Head range Motors 3-185 U.S. gpm 15 U.S. gpm 18-54 ft TEFC (standard) / ODP (optional) Temp. range [ F ( C)] +5 to +25 (-15 to +121 ) Max. working pressure Flanges: 175 psi 2 1/2" ANSI 125 lb. F.F. *575V available on request. 11

7 LM, LP 2.5 LM 8/XX H [m] H [ft] 7 2 6 5% 55% 6% 65% 7% 72% 7% 2.5 LM 8 6 Hz 175 RPM 15 5 65% 6% 4 55% 1 3 /8. 5 2 NPSH [ft] 1 1 5 NPSHR 2 4 6 8 1 12 14 16 18 2 Q [US GPM] 5 1 15 2 25 3 35 4 45 5 Q [m³/h] P2 [hp] /8. 3.2 2.4 1.6.8. 2 4 6 8 1 12 14 16 18 Q [US GPM] TM2 4968 211 12

LM, LP 7 2.5 LM 8/XX 4 x Ø.63" Z B3 B4 D1 D2 D4 H3 H1 H2 L2 B1 B2 L1 2 x 1/4".25" NPT F D5 2 x Ø.69" ø11/16" 44 x x ø9/16" Ø.56" 2 x M16 x 1.125" 1 1/8" DP 7 7.69" 11/16" 9 9.25" 1/4" 1.38" 1 3/8" 5 " 11/16" 7 7.69" 11/16" 99.25" 1/4" TM2 4964 211 Electrical data, weights and dimensions Pump type Hp Mtr S.F. Ph NEMA Frame size Volts Dimensions [inches (mm)] D1 D4 D5 B1 B2 B3 B4 H1 H2 H3 L1 L2 Ship. wt. [lbs] 2.5 LM 8/8. 5. 1.15 1 215TC 23 3 184TC 28-23/ 46, 575* 2.5 (64) 2.5 (64) 5.5 (14) 5.5 (14) 7. (178) 7. (178) 1.62 (27) 8.6 (218) 8.6 (25) 6.97 (177) 6.18 (157) 6.18 (157) 5.94 (151) 5.94 (151) 4.56 (116) 4.56 (116) 7.38 (187) 7.38 (187) 27.22 (691) 25.62 (651) 19. (483) 19. (483) 9.5 (241) 9.5 (241) 258 213 Technical data Nominal flow range Min. flow rate Head range Motors 45-23 U.S. gpm 15 U.S. gpm 38-66 ft TEFC (standard) / ODP (optional) Temp. range [ F ( C)] +5 to +25 (-15 to +121 ) Max. working pressure Flanges: 175 psi 2 1/2" ANSI 125 lb. F.F. *575V available on request. 13

7 LM, LP 3. LM 5/XX H [m] H [ft] 1 3 8 25 5% 6% 7% 78% 3. LM 5 6 Hz 175 RPM 6 2 75% 15 55% 65% 78% /5.4 4 1 75% 78% /5. NPSH [ft] 2 2 5 /4.6 1 NPSHR 4 8 12 16 2 24 Q [US GPM] 1 2 3 4 5 6 Q [m³/h] P2 [hp] 2. 1.6 1.2.8 /5. /4.6 /5.4.4. 4 8 12 16 2 24 Q [US GPM] TK2 4969 192 TM2 4969 211 14

LM, LP 7 3. LM 5/XX 4 x Ø.63" Z B3 B4 D1 D2 D4 H3 H1 H2 L2 B1 B2 L1 2 x 1/4".25" NPT F D5 2 x Ø.69" ø11/16" 44 x x ø9/16" Ø.56" 2 x M16 x 1.125" 1 1/8" DP 7 7.69" 11/16" 9 9.25" 1/4" 1.38" 1 3/8" 5 " 11/16" 7 7.69" 11/16" 99.25" 1/4" TM2 4964 211 Electrical data, weights and dimensions Pump type Hp Mtr S.F. Ph NEMA Frame size Volts Dimensions [inches (mm)] D1 D4 D5 B1 B2 B3 B4 H1 H2 H3 L1 L2 Ship. wt. [lbs] 3. LM 5/4.6 1. 1.15 1 56C 115/23 1. 1.25 3 56C 28-23/4 6, 575* 3. 3. 6. 6. 7.5 7.5 7.19 (183) 7.19 (183) 5.75 (146) 5.75 (146) 6.25 (159) 6.25 (159) 4.89 (124) 4.89 (124) 5.5 (14) 5.5 (14) 21.82 (554) 2.8 (528) 21. 21. 1.5 1.5 13 153 3. LM 5/5. 1.5 1.15 1 56C 1.5 1.15 3 56C 115/ 28-23 28-23/4 6, 575* 3. 3. 6. 6. 7.5 7.5 7.19 (183) 7.19 (183) 5.75 (146) 5.75 (146) 6.25 (159) 6.25 (159) 4.89 (124) 4.89 (124) 5.5 (14) 5.5 (14) 22.69 (576) 21.8 (574) 21. 21. 1.5 1.5 179 162 3. LM 5/5.4 2. 1.15 1 56C 115/23 2. 1.15 3 56C 28-23/4 6, 575* 3. 3. 6. 6. 7.5 7.5 7.19 (183) 7.19 (183) 5.75 (146) 5.75 (146) 6.25 (159) 6.25 (159) 4.89 (124) 4.89 (124) 5.5 (14) 5.5 (14) 22.69 (576) 21.8 (554) 21. 21. 1.5 1.5 179 151 Technical data Nominal flow range Min. flow rate Head range Motors 65-31 U.S. gpm 25 U.S. gpm 6-28 ft TEFC (standard) / ODP (optional) Temp. range [ F ( C)] +5 to +25 (-15 to +121 ) Max. working pressure Flanges: 175 psi 2 1/2" ANSI 125 lb. F.F. *575V available on request. 15

7 LM, LP 3. LM 6/XX H [m] H [ft] 14 45 12 4 35 1 55% 5% 65% 6% 7% 74% 74% 7% 3. LM 6 6 Hz 175 RPM 3 8 25 6% 6 4 2 15 65% 55% /6.3 5% /6.6 NPSH [ft] 15 1 1 2 5 NPSHR 5 4 8 12 16 2 24 28 32 36 Q [US GPM] 1 2 3 4 5 6 7 8 Q [m³/h] P2 [hp] 4 /6.6 3 /6.3 2 1 4 8 12 16 2 24 28 32 36 Q [US GPM] TK2 497 192 TM2 497 211 16

LM, LP 7 3. LM 6/XX 4 x Ø.63" Z B3 B4 D1 D2 D4 H3 H1 H2 L2 B1 B2 L1 2 x 1/4".25" NPT F D5 2 x Ø.69" ø11/16" 44 x x ø9/16" Ø.56" 2 x M16 x 1.125" 1 1/8" DP 1.38" 1 3/8" 7 7.69" 11/16" 9 9.25" 1/4" 5 " 11/16" 7 7.69" 11/16" 99.25" 1/4" TM2 4964 211 Electrical data, weights and dimensions Pump type Hp Mtr S.F. Ph NEMA Frame size Volts Dimensions [inches (mm)] D1 D4 D5 B1 B2 B3 B4 H1 H2 H3 L1 L2 Ship. wt. [lbs] 3. LM 6/6.3 3. 1.15 1 184TC 115/23 3 182TC 28-23, 46, 575* 3. 3. 6. 6. 7.5 7.5 8.6 (218) 7.19 (183) 6.87 (175) 5.75 (146) 7.13 (181) 7.13 (181) 5.94 (151) 5.94 (151) 7.56 (192) 7.56 (192) 26.37 (67) 26.37 (67) 21. 21. 1.5 1.5 25 2 3. LM 6/6.6 5. 1.15 1 215TC 23 3 184TC 28-23, 46, 575* 3. 3. 6. 6. 7.5 7.5 1.62 (27) 8.6 (218) 8.6 (25) 6.97 (177) 7.13 (181) 7.13 (181) 5.94 (151) 5.94 (151) 8.88 (225) 8.88 (225) 29.29 (744) 27.69 (73) 21. 21. 1.5 1.5 281 232 Technical data Nominal flow range Min. flow rate Head range Motors 65-4 U.S. gpm 25 U.S. gpm 16-46 ft TEFC (standard); ODP (optional) Temp. range [ F ( C)] +5 to +25 (-15 to +121 ) Max. working pressure Flanges: 175 psi 3" ANSI 125 lb. F.F. *575V available on request. 17

7 LM, LP 3. LM 8/XX H [m] H [ft] 7 2 6 15 5 5% 6% 55% 65% 7% 75% 76% 78% 75% 7% 3. LM 8 6 Hz 175 RPM /8.3 4 1 3 2 /7.4 NPSH [ft] 2 5 1 1 NPSHR 4 8 12 16 2 24 28 32 36 4 Q [US GPM] 1 2 3 4 5 6 7 8 9 1 Q [m³/h] P2 [hp] /8.3 6 5 /7.4 4 3 2 1 4 8 12 16 2 24 28 32 36 4 Q [US GPM] TK2 4971 192 TM2 4971 211 18

LM, LP 7 3. LM 8/XX 4 x Ø.63" Z B3 B4 D1 D2 D4 H3 H1 H2 L2 B1 B2 L1 2 x 1/4".25" NPT F D5 2 x Ø.69" ø11/16" 44 x x ø9/16" Ø.56" 2 x M16 x 1.125" 1 1/8" DP 7 7.69" 11/16" 9 9.25" 1/4" 1.38" 1 3/8" 5 " 11/16" 7 7.69" 11/16" 99.25" 1/4" TM2 4964 211 Electrical data, weights and dimensions Pump type Hp Mtr S.F. Ph NEMA Frame size Volts Dimensions [inches (mm)] D1 D4 D5 B1 B2 B3 B4 H1 H2 H3 L1 L2 Ship. wt. [lbs] 3. LM 8/7.4 5. 1.15 1 215TC 23 3 184TC 28-23/ 46, 575* 3. 3. 6. 6. 7.5 7.5 1.62 (27) 8.6 (218) 8.6 (25) 6.97 (177) 7.13 (181) 7.13 (181) 5.94 (151) 5.94 (151) 8.88 (225) 8.88 (225) 29.29 (744) 27.69 (73) 21. 21. 1.5 1.5 31 241 3. LM 8/8.3 1 1.15 3 215TCZ 28-23/ 46, 575* 3. 6. 7.5 1.28 (261) 8.6 (25) 7.13 (181) 5.94 (151) 9.88 (251) 31.42 (798) 21. 1.5 281 Technical data Nominal flow range Min. flow rate Head range Motors 9-46 U.S. gpm 25 U.S. gpm 29-71 ft TEFC (standard) / ODP (optional) Temp. range [ F ( C)] +5 to +25 (-15 to +121 ) Max. working pressure Flanges: 175 psi 3" ANSI 125 lb. F.F. *575V available on request. 19

7 LM, LP 2.5 LP 5/XX H [m] H [ft] 1 3 9 25 8 7 2 6 4% 5% 6% 45% 55% 7% 65% 71% 72% 75% 7% 2.5 LP 5 6 Hz 345 RPM 15 1 5 5 4 3 2 65% 6% 55% /4.6 5% /4.3 /5. NPSH [ft] 2 1 NPSHR 1 4 8 12 16 2 24 28 Q [US GPM] 1 2 3 4 5 6 7 Q [m³/h] P2 [hp] /5. 6 /4.6 5 /4.3 4 3 2 1 4 8 12 16 2 24 28 Q [US GPM] TK2 4972 192 TM2 4972 211 2

LM, LP 7 2.5 LP 5/XX 4 x Ø.63" Z B3 B4 D1 D2 D4 H3 H1 H2 L2 B1 B2 L1 2 x 1/4".25" NPT F D5 2 x Ø.69" ø11/16" 44 x x ø9/16" Ø.56" 2 x M16 x 1.125" 1 1/8" DP 7 7.69" 11/16" 9 9.25" 1/4" 1.38" 1 3/8" 5 " 11/16" 7 7.69" 11/16" 99.25" 1/4" TM2 4964 211 Electrical data, weights and dimensions Pump type Hp Mtr S.F. Ph NEMA Frame size Volts Dimensions [inches (mm)] D1 D4 D5 B1 B2 B3 B4 H1 H2 H3 L1 L2 Ship. wt. [lbs] 2.5 LP 5/4.3 5. 1.15 1 213TC 28-23 3 184TC 28-23/ 46, 575* 2.5 (64) 2.5 (64) 5.5 (14) 5.5 (14) 7. (178) 7. (178) 1.62 (27) 8.66 (22) 7.46 (19) 5.28 (134) 4.38 (111) 4.38 (111) 4.56 (116) 4.56 (116) 6. 6. 25.84 (656) 26.7 (662) 19. (483) 19. (483) 9.5 (241) 9.5 (241) 29 185 2.5 LP 5/4.6 5. 1.15 1 213TC 28-23 3 184TC 28-23/ 46, 575* 2.5 (64) 2.5 (64) 5.5 (14) 5.5 (14) 7. (178) 7. (178) 1.62 (27) 8.66 (22) 7.46 (19) 5.28 (134) 4.38 (111) 4.38 (111) 4.56 (116) 4.56 (116) 6. 6. 25.84 (656) 26.7 (662) 19. (483) 19. (483) 9.5 (241) 9.5 (241) 214 185 2.5 LP 5/5. 7.5 1.15 1 213TC 28-23 3 215TC 28-23/ 46, 575* 2.5 (64) 2.5 (64) 5.5 (14) 5.5 (14) 7. (178) 7. (178) 1.23 (26) 1.23 (26) 7.62 (194) 8.6 (25) 4.38 (111) 4.38 (111) 4.56 (116) 4.56 (116) 6. 6. 25.84 (656) 25.84 (656) 19. (483) 19. (483) 9.5 (241) 9.5 (241) 221 21 Technical data Nominal flow range Min. flow rate Head range Motors 6-3 U.S. gpm 15 U.S. gpm 3-12 ft TEFC (standard) / ODP (optional) Temp. range [ F ( C)] +5 to +25 (-15 to +121 ) Max. working pressure Flanges: 175 psi 2 1/2" ANSI 125 lb. F.F. *575V available on request. 21

7 LM, LP 3. LP 5/XX H [m] H [ft] 12 35 11 3 1 9 25 8 7 2 4% 5% 6% 7% 75% 79% 8% 3. LP 5 6 Hz 345 RPM 75% /5.2 6 /4.9 15 5 4 NPSH [ft] 4 1 3 3 5 2 2 1 NPSHR 1 4 8 12 16 2 24 28 32 Q [US GPM] 1 2 3 4 5 6 7 8 Q [m³/h] P2 [hp] 8 /5.2 6 /4.9 4 2 4 8 12 16 2 24 28 32 Q [US GPM] TM2 4973 211 22

LM, LP 7 3. LP 5/XX 4 x Ø.63" Z B3 B4 D1 D2 D4 H3 H1 H2 L2 B1 B2 L1 2 x 1/4".25" NPT F D5 2 x Ø.69" ø11/16" 44 x x ø9/16" Ø.56" 2 x M16 x 1.125" 1 1/8" DP 1.38" 1 3/8" 7 7.69" 11/16" 9 9.25" 1/4" 5 " 11/16" 7 7.69" 11/16" 99.25" 1/4" TM2 4964 211 Electrical data, weights and dimensions Pump type Hp Mtr S.F. Ph NEMA Frame size Volts Dimensions [inches (mm)] D1 D4 D5 B1 B2 B3 B4 H1 H2 H3 L1 L2 Ship. wt. [lbs] 3. LP 5/4.9 7.5 1.15 1 213TC 28 3 215TC 28-23/4 6, 575 3. 3. 6. 6. 7.5 7.5 1.23 (26) 1.23 (26) 7.62 (194) 8.6 (25) 6.25 (159) 6.25 (159) 4.88 (124) 4.88 (124) 7.94 (22) 7.94 (22) 28.35 (72) 28.35 (72) 21. 21. 1.5 1.5 229 213 3. LP 5/5.2 1 1.15 1 215TC 23 3 215TC 28-23/4 6, 575 3. 3. 6. 6. 7.5 7.5 1.23 (26) 1.23 (26) 1.3 (262) 8.6 (25) 6.25 (159) 6.25 (159) 4.88 (124) 4.88 (124) 7.94 (22) 7.94 (22) 28.89 (734) 28.35 (72) 21. 21. 1.5 1.5 26 27 Technical data Nominal flow range Min. flow rate Head range Motors 45-37 U.S. gpm 25 U.S. gpm 59-114 ft TEFC (standard); ODP (optional) Temp. range [ F ( C)] +5 to +25 (-15 to +121 ) Max. working pressure Flanges: 175 psi 3" ANSI 125 lb. F.F. *575V available on request. 23

7 LM, LP 3. LP 6/XX H [m] H [ft] 55 18 5 16 45 14 4 12 35 4% 45% 5% 55% 6% 62% 65% 6% 6% 3. LP 6 6 Hz 345 RPM 5% 3 1 /6.6 55% 25 8 /6.1 2 15 1 6 4 45% /5.6 NPSH [ft] 16 5 2 NPSH 8 4 8 12 16 2 24 28 32 Q [US GPM] 1 2 3 4 5 6 7 8 Q [m³/h] P2 [hp] 16 12 8 /5.6 /6.1 /6.6 4 4 8 12 16 2 24 28 32 Q [US GPM] TM2 4974 211 24

LM, LP 7 3. LP 6/XX 4 x Ø.63" Z B3 B4 D4 H3 H1 H2 B1 B2 2 x 21/4" x.25" NPT F D1 L2 D2 L1 D5 42 x M16 x 1.125" 1 1/8" DP TM2 4965 192 Electrical data, weights and dimensions Pump type Hp Mtr S.F. Ph NEMA Frame size 3. LP 6/5.6 15 1.15 3 254TC 3. LP 6/6.1 15 1.15 3 254TC Volts 28-23 46/575* 28-23 46/575* 3. LP 6/6.6 2 1.15 3 254TC 23/46, 575* Dimensions [inches (mm)] D1 D4 D5 B1 B2 B3 B4 H1 H2 H3 L1 L2 3. 3. 3. 6.63 (168) 6.63 (168) 6.63 (168) 6. 6. 6. 7.5 7.5 7.5 1.23 (26) 1.23 (26) 13.26 (337) 8.69 (221) 8.69 (221) 9.49 (241) 6.19 (157) 6.19 (157) 6.19 (157) 5.94 (151) 5.94 (151) 5.94 (151) 8.44 (214) 8.44 (214) 8.44 (214) 3.38 (772) 3.38 (772) 33.76 (858) 21. 21. 21. 1.5 1.5 1.5 Ship. wt. [lbs] 312 312 415 Technical data Nominal flow range Min. flow rate Head range Motors 65-35 U.S. gpm 25 U.S. gpm 55-18 ft TEFC (standard); ODP (optional) Temp. range [ F ( C)] +5 to +25 (-15 to +121 ) Max. working pressure Flanges: 175 psi 2 1/2" ANSI 125 lb. F.F. *575V available on request. 25

7 LM, LP 4. LP 5/XX H [m] H [ft] 4 13 12 35 11 3 1 9 4% 5% 6% 7% 75% 77% 76% 4. LP 5 6 Hz 345 RPM 75% 25 8 /5.5 2 7 6 45% 55% 76% /5.2 15 1 5 4 3 65% 67% 65% 6% 55% /4.3 /4.9 NPSH [ft] 4 3 5 2 2 1 NPSHR 1 5 1 15 2 25 3 35 4 45 5 Q [US GPM] 1 2 3 4 5 6 7 8 9 1 11 12 13 Q [m³/h] P2 [hp] /5.5 16 /5.2 12 /4.9 8 /4.3 4 5 1 15 2 25 3 35 4 45 5 Q [US GPM] TK2 4975 192 TM2 4975 211 26

LM, LP 7 4. LP 5/XX 4 x Ø.63" Z B3 B4 D4 H3 H1 H2 B1 B2 2 x.25" 1/4" NPT F D1 L2 D2 L1 D5 42 x M16 x 1.125" 1 1/8" DP TM2 4963 211 Electrical data, weights and dimensions Pump type 4. LP 5/4.3 4. LP 5/4.9 Hp Mtr S.F. Ph NEMA Frame size Volts 7.5 1.15 1 213TC 28-23 7.5 1.15 3 215TC 28-23/ 46, 575* 1 1.15 1 215TC 23 1 1.15 3 215TC 28-23/ 46, 575* 4. LP 5/5.2 15 1.15 3 254TC 28-23/ 46, 575* 4. LP 5/5.5 2 1.15 3 284TC 28-23/ 46, 575* Dimensions [inches (mm)] D1 D4 D5 B1 B2 B3 B4 H1 H2 H3 L1 L2 4 (12) 4 (12) 4 (12) 4 (12) 4 (12) 4 (12) 6.63 (168) 6.63 (168) 6.63 (168) 6.63 (168) 6.63 (168) 6.63 (168) 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 7.5 1.23 (26) 1.23 (26) 1.23 (26) 1.23 (26) 1.23 (26) 13.26 (337) 7.62 (194) 8.6 (25) 1.3 (262) 8.6 (25) 8.69 (221) 9.49 (241) 6.75 (171) 6.75 (171) 6.75 (171) 6.75 (171) 6.75 (171) 6.75 (171) 5.56 (141) 5.56 (141) 5.56 (141) 5.56 (141) 5.56 (141) 5.56 (141) 9.81 (249) 9.81 (249) 9.81 (249) 9.81 (249) 9.81 (249) 9. (229) 3.22 (768) 3.22 (768) 3.76 (781) 3.22 (768) 31.75 (87) 34.32 (872) 21. 21. 21. 21. 21. 21. 1.5 1.5 1.5 1.5 1.5 1.5 Ship. wt. [lbs] 246 28 265 39 334 44 Technical data Nominal flow range Min. flow rate Head range Motors 13-63 U.S. gpm 5 U.S. gpm 3-124 ft TEFC (standard); ODP (optional) Temp. range [ F ( C)] +5 to +25 (-15 to +121 ) Max. working pressure Flanges: 175 psi 4" ANSI 125 lb. F.F. *575V available on request. 27

7 LM, LP LM 4-pole motor data Product number Power [Hp] Ph Service factor Supply voltage [V] Frame size Eff [%] LM 4-pole motor data Efficiency rating* Temp. class KVA code FLA SFA LRA Motor mfg. 85713.75 1 1.25 115/28-23 56C 68 not defined B N 11/6.-5.5 12.6/7.-6.3 38.3-34.6/17.3 Baldor 85613.75 3 1.25 28-23/46 56C 75.5 not defined B K 3.2-3./1.5 3.6-3.4/1.7 22.1-2/1 Baldor 85714 1. 1 1.15 115/23 56C 67 not defined B K 13/6.5 14.2/7.1 74/37 Baldor 84Z4924 1. 3 1.15 28-23/46 56CZ 82.5 EE B M 3.4-3.2/1.6 3.6-3.4/1.7 29.2-26.4/13.2 Baldor 86685 1.5 1 1.15 115/28-23 56C 72 not defined B J 16/8.2-8. 18.5/1.2-9.25 252-228/114 Baldor 84Z4925 1.5 3 1.15 28-23/46 56CZ 84 EE B M 5.1-4.8/2.4 5.4-5.1/2.55 42-38/19 Baldor 86686 2. 1 1.15 115/23 56C 78 not defined F J 17.2/8.6 19.2/9.6 64.7-58.5/29.25 Baldor 84Z4926 2. 3 1.15 28-23/46 56CZ 84 EE B L 6.4-6.2/3.1 7-6.8/3.4 52.6-47.6/23.8 Baldor 86688 3. 1 1. 115/23 184TCZ 78 not defined F K 28/14 N/A 21/15 Baldor 84Z4927 3. 3 1.15 28-23/46 182TCZ 87.5 EE F L 9.1-8.4/4.2 9.7-9.2/4.6 8.9-73.2/36.6 Baldor 866812 5. 1 1. 23 215TC 82.5 not defined B K 22 N/A 195 Baldor 84Z4928 5. 3 1.15 28-23/46 184TCZ 87.5 EE F K 15.4-14.2/7.1 16-15.2/7.6 118.5-17.2/53.6 Baldor 84Z493 1 3 1.15 28-23/46 215TCZ 89.5 EE F K 28-27/13.5 31.4-3/15 236.6-214/17 Baldor LP 2-pole motor data LM 2-pole motor data Product number Power [Hp] Ph Service factor Supply voltage [V] Frame size Eff [%] Efficiency rating* Temp. class KVA code FLA SFA LRA Motor mfg. 85712 5. 1 1.15 28-23 213CZ 8 not defined F J 24-22 27-25 189-17 Baldor 84Z513 5. 3 1.15 28-23/46 182TCZ 87.5 EE F K 12.6-11.6/5.8 14.2-13.2/6.6 119.4-18/54 Baldor 85717 7.5 1 1.15 28-23 213TC 82 not defined F F 33.8-31 38.5-35.5 244-22 Baldor 84Z4858 7.5 3 1.15 28-23/46 213TCZ 88.5 EE F J 19.5-17.8/8.9 22-2.2/1.1 163.2-147.6/73.8 Baldor 85722 1 1 1.15 23 213TC 85.5 not defined F F 4 46 284 Baldor 84Z5199 1 3 1.15 28-23/46 215TCZ 89.5 EE F H 25-23/11.5 29.2-26.4/13.2 199-18/9 Baldor 84Z543 15 3 1.15 28-23/46 254TCZ 9.2 EE F K 37.5-34/17 42.5-39/19.5 336.2-34/152 Baldor 84Z4921 2 3 1.15 28-23/46 284TSCZ 9.2 EE F J 49-46/23 58-52/26 418-378/189 Baldor * EE = NEMA Energy Efficient, PE = NEMA Premium Efficient (PE is available on request) 28

LM, LP 7 This page intentionally left blank. 29

8 LM, LP Further product documentation 8. Further product documentation WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185, Grundfos products in more than 2 languages. In WebCAPS, all information is divided into 6 sections: Catalog Literature Service Sizing Replacement CAD drawings. Catalog This section is based on fields of application and pump types, and contains technical data curves (QH, Eta, P1, P2, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation product photos dimensional drawings wiring diagrams quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as product guides installation and operating instructions service documentation, such as Service kit catalog and Service kit instructions quick guides product brochures, etc. Service This section contains an easy-to-use interactive service catalog. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts. 3

1 LM, LP 8 Sizing This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to select the most suitable and efficient pump for your installation carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. analyse your selected pump via the built-in life cycle cost tool determine the flow velocity in wastewater applications, etc. Replacement Further product documentation In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings:.dxf, wireframe drawings.dwg, wireframe drawings. 3-dimensional drawings:.dwg, wireframe drawings (without surfaces).stp, solid drawings (with surfaces).eprt, E-drawings. WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185, Grundfos products in more than 2 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year. WinCAPS CD-ROM 31

8 LM, LP Further product documentation This page intentionally left blank. 32

LM, LP 9 9. Submittal data sheet LM, LP single-stage close coupled in-line circulating pumps Company name... Prepared by... Phone number (...)... Fax number (...)... Date:... Page 1 of:... Submittal data sheet Quote number:... Client information Project title:... Reference number:... Client contact:... Client name:... Client number:... Client phone:... Location information For:... Site:... Unit:... Service:... Address:... City:... State:... Zip code:... Pump information Model information from type key and codes: Min. required flow:...... Example: 2.5 LM 6/6.2 U-G-A-BBUE... Quantity required:... NPSH required at duty point:... Technical data Flow (gpm):... Head (Ft)... Motor:... Max. liquid temp.:... Motor information Hp:... Phase:... Voltage:... Enclosure:... Min. liquid temp.:... Min. required inlet pressure:... Connection type and size:... Product guide additional information pages Materials page number:... Technical data page number:... Performance curve page number:... Motor data page number:... Variant pump information (optional):...... Additional information:...... 33

34 This page intentionally left blank.

This page intentionally left blank. 35

Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence L-MLP-PG-1 Rev. 7.11 Repl. 9.2 22, 211 Grundfos Pumps Corp. US The name Grundfos, the Grundfos logo, and the payoff Be Think Innovate are registrated trademarks owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide. GRUNDFOS Pumps Corporation 171 West 118th Terrace Olathe, Kansas 6661 Phone: +1-913-227-34 Telefax: +1-913-227-35 GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Canada Phone: +1-95 829 9533 Telefax: +1-95 829 9512 Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto Apodaca, N.L. Mexico 666 Phone: +52-81-8144 4 Telefax: +52-81-8144 41