Section - B. Air vents

Similar documents
MVD, MV, MKV, MKL, 2161C, MXV Series

D-26. Combination Air Valve for Wastewater. Description. Applications. Operation. Main Features

WATTS INDUSTRIES UK LTD

D-023 PN 16 / 25. Combination Air Valve for Wastewater PATENTED. Description. Applications. Operation. Main Features

COMPONENTS FOR SOLAR THERMAL SYSTEMS

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Important Product range Technical specifications

TECHNICAL CATALOGUE AIR VENT VALVES AND SAFETY VALVES

Mild Steel Dosing Pots

AUTOMATIC AIR VALVES For potable water

COMPONENTS FOR SOLAR THERMAL SYSTEMS

HAWLE-AIR RELEASE VALVES

Section - C. Boiler components

INSTALLATION AND COMMISSIONING MANUAL CONTENTS. Function. Product range. Technical specifications. Characteristic components

548 hydraulic separator

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

Section - L. Antipollution devices

SECTION VALVES PART 1 -GENERAL

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Components for central heating

FO-BV Series. Fixed-orifice balancing and control valves. Technical Data Sheet. WattsIndustries.com

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

D-040 PN 16 D-040-C PN 16. Combination Air Valve. Description. Applications. Operation. Main Features

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

40 geothermal ground loop manifolds

YARWAY HANCOCK Y-PATTERN FORGED STEEL GLOBE STOP VALVES SERIES 4000

Dry Pillar Hydrant Type ADR with pre-set break. Technical Bulletin. code. General description

Technical changes kept in reserve THROUGH CONDUIT KNIFE GATE VALVE

Automatic Control Valves WATTS EU 100 Series

3 & 4 WAY DIVERTER VALVES DESIGN FEATURES

Fan-coil valves Series

Automatic Waste Water Pump Station. Evamatic-Box N. Type Series Booklet

Valves for building. Y-strainers... page 204 PVC valves Ball valves... page 204 Butterfly valve... page 204 Ball check valve...

Standard Specifications Model. How to Order. Mist spray unit. Recommended Equipment. Mixing valve

Pressure Relief Valves. 1541/1543 Series. Consolidated Safety Valve

Type 441 XXL 442 XXL. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

Series Direct contact, metal-to-metal seating, make the globe valve ideal for most shut-off applications. Features

Preassembled manifolds with flow meter, series CPRFL

Sempell High Pressure Stop Valves Model VA500 (ASME)

PARTS SPECIFICATIONS

Valves for building. Y-strainers... page 272 PVC valves Ball valves... page 272 Butterfly valves... page 272 Ball check valves...

Type 441 DIN 442 DIN. Facts. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. US Units

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

ROBERT H. WAGER COMPANY. Installation, Operation and Maintenance Guide. Models 1500/1500-MC 1700/1750

Series 36-WW COMBINATION AIR VALVES DATA AND SIZING WASTEWATER SERVICE. (Single Body Style) Installation. Specifications. Purchase Specification

Section - N. Components for oil-fired heating

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

funnels, measures, gravity cocks, jerry cans and oil suction pumps...

Guide Specification SECTION HYDRONIC PIPING SPECIALTIES PART 1 - GENERAL 1.1 SUMMARY

Pump Station. Ama-Porter CK Pump Station. Type Series Booklet

Series Direct contact and metal-to-metal seating makes the T-pattern globe stop valve ideal for most shut-off applications.

13900 Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

DAV - M DAV-M. Air Release and Vacuum Break Valves. Product Catalogue. (Metal Air Valves) DAV-M

AUTOMATIC CONTROL VALVES. TIS asia

Electro Controls. Valves / Linkages WattsIndustries.co.uk

The Universal Sewer Air Release Valve is designed to permit

15100 VALVES. E. Section Building Automation and Control System Guidelines

FLOAT CONTROL VALVES

Valves, controls + systems Valves and controls for solar installations Regusol-180

PRESSURE CONTROL VALVES SABS 198

Emergency Shear Valves

BUD: 3-way flanged valve, PN 6 (pn.)

THROUGH CONDUIT KNIFE GATE VALVE. OBX 09/11 2nd EDITION Revision 1 Reserves the right to change specifications without notice

CUSTOM COMBINATION AIR VALVE

RUBBER SLEEVE KNIFE GATE VALVE

VUD: 2-way flanged valve, PN 6 (pn.)

HIGH PERFORMANCE BUTTERFLY VALVE

RUBBER SLEEVE KNIFE GATE VALVE

RUBBER SLEEVE KNIFE GATE VALVE

TECHNICAL INSTRUCTIONS

TECHNICAL CATALOGUE AUTOMATIC AIR-VENT VALVES

485 - NC NO/DA DN

Bearings. Shaft seal. Materials

Axially split volute casing pumps. Applications. Bearings. Shaft seal. Operating data

ALTITUDE CONTROL VALVES FOR ONE WAY FLOW

125 EXPANSION VESSEL J N O

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

Booster Pump Control Valve

CALEFFI. Modulating temperature regulating unit with distribution kit for primary circuit. 171 series 01153/15 GB. replaces 01153/07 GB

The bellows sealed valve

Valves Range RVRX - Resilient Seated Gate Valve PN16 Flange

CALEFFI. Diverter and isolation valves for panel radiators. 3010, 3011, 3012, 3013 series 01036/12 NA. Function. Product range

NARVIK-YARWAY. High Pressure Level Gauges, Model: 17

Elbow ball check valves PRODUCT CATALOG

Technote. Frese ALPHA - automatic balancing valve. Application. Benefits. Features.

Pressure Relief Valves Series. Consolidated Safety Valve

From PN10 to PN100 (from ANSI125 to ANSI600)

Sempell High Pressure Stop Valves Model VA510 (DIN)

Series 34. Specifications

Modulating Water Valves and Bulb Wells

Bronze Gate Valves. SECTION 2a. Tel: +44 (0) Fax: +44 (0)

MODULATING FLOAT CONTROL VALVE

SB UNDERGROUND AIR VALVE ASSEMBLY INTRODUCTION FEATURES INSTALLATION

US SERIES. Universal Sewer Valves. Universal Sewer Valves. Valve Function. Features Include

BUE: 3-way flanged valve, PN 16/10 (el.)

OIL FILLER AND AIR BREATHER FILLER CAPS

LCS6822 (Class 150) LCS7822 (Class 300)

SELF-CLEANING FILTER

Liquid filters _ 302. Deaerators. Product Bulletin

VALVE FEATURES AVAILABLE MODELS LIMITS OF USE IP 67

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

Transcription:

Section - Air vents

AIR VENTS EXAMPLE OF APPLICATION 2 1 2 4 5 2 3 3 4 6 1 Automatic air vent valves. 2 Manual air vent valves. 3 Air vent valves with adjustable discharge nozzle. 4 Air vents with float.. 5 Automatic large capacity air separator. 6 Automatic deaerators.

AIR VENTS AUTOMATIC, MANUAL AND WITH ADJUSTALE DISCHARGE AIR VENT VALVES 228C HYGROVENT Automatic air vent valve, with check device and discharge nozzle. Chrome-plated brass body CW617N. Max. pressure: 6 bar. 3 228C 2280C18X 1/8" 100 228C 2281C14X 1/4" 100 228C 2282C38X 3/8" 100 SMC Manual deaerating valve for radiators. Adjustable discharge spout opened by screwdriver or coin. Complete with O ring. Chrome-plated brass body CW6179N. Max. pressure: 10 bar SMC 0257006 1/8" 100 SMC 0257008 1/4" 100 SMC 0257010 3/8" 100 SMC 0257015 1/2" 100 238C Manual air vent valve, with discharge nozzle. Chrome-plated brass body CW617N. Max. pressure: 10 bar. 238C 2381C18X 1/8" 100 238C 2382C14X 1/4" 100 238C 2383C38X 3/8" 100 231C "Super" manual air vent valve, with discharge nozzle. Chrome-plated brass body CW617N. Max. pressure: 10 bar. 231C 231C18SNX 1/8" 100 231C 231C14SNX 1/4" 100 231C 231C38SNX 3/8" 100 Hygrovent When the hygroscopic discs change from the moist state to the dry state, they decrease in volume thereby allowing automatic discharge of the air present Knurled handwheel for manual operation Fibre hygroscopic discs uilt-in check valve for changing hygroscopic discs

AIR VENTS AUTOMATIC, MANUAL AND WITH ADJUSTALE DISCHARGE AIR VENT VALVES 4 VMM Manual air vent valve for radiators, with adjustable discharge nozzle. Manual discharge opening through screw driver, coin. Chrome-plated brass body CW617N. Glass fibre reinforced nylon handwheel and discharge nozzle body. Sealed on radiator through O-ring. Max. operating pressure: 10 bar. VMM 0256206 1/8" 100 VMM 0256208 1/4" 100 VMM 0256210 3/8" 100 PMC Manual air vent valve for radiators, with adjustable discharge nozzle. Manual vent opening through screw driver, coin. Chrome-plated brass body CW617N. Glass fibre reinforced nylon discharge nozzle. Sealed on radiator through O-ring. Max. pressure : 10 PMC 0256306 1/8" 100 PMC 0256308 1/4" 100 PMC 0256310 3/8" 100 PMC 0256315 1/2" 100 RSR Drain valve for radiators. Chrome-plated brass body. Adjustable plastic discharge nozzle. Sealed on radiator through O-ring. RSR 0256008 1/4" 100 RSR 0256010 3/8" 100 RSR 0256015 1/2" 100 SMM Manual air vent valve for radiators, with adjustable discharge nozzle. Knurled handwheel. Chrome-plated brass CW617N body and discharge nozzle. Sealed on radiator through O-ring. Max. pressure : 10 bar. SMM 0257106 1/8" 100 SMM 0257108 1/4" 100 SMM 0257110 3/8" 100 SMM 0257115 1/2" 100 Manual air vent valve VMM PMC CH Inlet hole smaller than the outlet hole to avoid infiltration of particles which could block air discharge. O-ring for easy assembly and perfectly tight seal on the radiator. Handwheel designed for manual opening with screw-driver or coin. Limit stop on the screw to avoid the handwheel coming out from the valve body. Adjustable discharge nozzle, glass fibre reinforced nylon body. Valve handwheel PMC with opening by screw-driver or coin. Insert for adjusting discharge nozzle body. Wrench CH can be left inserted on the body. Insert for opening valves PMC, RSR insert for opening valve VMM

AIR VENTS AIR VENTS WITH FLOAT MVDR DUOVENT (PATENTED) Automatic and manual air vent valve with unscrewable cover for inspection complete with automatic shut-off valve RIA. ody and cover of brass CW617N. Corrosion-resistant polyethylene float. Nominal pressure : 12 bar. Max. operating pressure: 8 bar. Max. temperature : 115 C. Automatic venting capacity at 3 bar : 17.9 litres/min. Manual venting capacity at 3 bar: 139.5 litres/min. Also suitable for water containing additive (glycol up to 30%). 5 MVDR 0250708 1/4" 10 MVDR 0250710 3/8" 10 MVDR 0250715 1/2" 10 Advantage of built-in manual discharge The ever increasing use of the horizontal Modul or Single-pipe distribution systems has led to the engineering of networks with small diameter piping, without slopes and with closed circuits, thus requiring the development of a special product line for venting air from the circuits. Compared to the conventional automatic operation with float determined by the water level in the heating system, the DUOVENT air vent valve offers the advantage of manual discharge which allows checking for correct operation and cleaning of the automatic discharge orifice as well as reducing emptying times. For manual discharge, unscrew the red cap and push the disc down with a screw driver. When held down, it allows the water to flow through the orifice. The presence of the shut-off valve allows maintenance operations without emptying the system. MANUAL DISCHARGE AUTOMATIC DISCHARGE Automatic and manual vent at the various pressures SHUT-OFF VALVE

AIR VENTS AIR VENTS WITH FLOAT 6 MVR MINIVENT Automatic air vent valve complete with automatic sealed shut-off valve RIA with unscrewable cover for inspection. ody and cover of brass CW617N. Corrosion-resistant polyethylene float. Max. pressure : 12 bar. Max. temperature : 115 C. Also suitable for water containing additive (glycol up to 30%) MVR 0250108 1/4" 10 MVR 0250110 3/8" 10 MVR 0250115 1/2" 10 MKVR MICROVENT Automatic vertical air vent valve complete with automatic sealed shut-off valve RIA. ody and cover of brass CW617N. Sealed with O-Ring Max. pressure : 10 bar. Max. temperature : 110 C. Also suitable for water containing additive (glycol up to 30%) MKVR 0251310 3/8" 10 MKLR MICROVENT Automatic side air vent valve complete with automatic sealed shut-off valve RIA. ody and cover of brass CW617N. Sealed with O-Ring Max. pressure : 10 bar. Max. temperature : 110 C. Also suitable for water containing additive (glycol up to 30%). MKLR 0252310 3/8" 10 MKL 0252410 1/2 10 INTR INTERVENT. Automatic vertical air vent valve complete with automatic shut-off valve RIA ody and cover of brass CW617N Max. pressure : 10 bar. Max. temperature : 115 C INT 0252110 3/8" 10 INT 0252115 1/2" 10

AIR VENTS AIR VENTS WITH FLOAT NEW FOR SOLAR SYSTEMS MV-SOL MINIVENT Automatic air vent valve for solar systems with unscrewable cover for inspection. ody and cover of brass CW617N, 1265-99. Polyethylene float. Seal between reservoir and cover with O-ring. Connection ND 3/8-1/2 DIN - ISO 228/1 Stainless steel (AISI 304) vacuum breaker (only for ND 3/8 ) Max. operating pressure : 12 bar. Max. operating temperature : 160 C. MV-SOL 0249110 3/8" 10 MV-SOL 0249115 1/2" 10 2161C FLOATVENT. Automatic vertical air vent valve. Sealed with O-ring. Designed for installation on head connections of flush manifolds. rass CW617N body. Max. pressure: 10 bar. Max. temperature: 110 C 7 2161C 2161C38 3/8" 50 2161C 2161C12 1/2" 50 2161C 2161C34 3/4" 50 2161C 2161C1 1" 50 2311C CHECKVENT. Sealed check valve for automatic vertical air vent valve 2161C38. 2311C 2311C38 3/8" 50 RIA Automatic shut-off valve for automatic air vent valves series MVD, MV, MKV, MKL. Complete with device for quick and total drainage of water from the valve. RIA 0259008 1/4" 10 RIA 0259010 3/8" 10 RIA 0259015 1/2" 10 MOV173 SUPERVENT. Automatic high capacity commercial air vent with screwable cover for inspection. Incorporates an automatic check valve to isolate water for maintenance. ody and cover of brass. Max. pressure 10 bar. Max temperature: 115 C MOV173 M16300 3/8" 1

AIR VENTS AIR SEPARATORS 8 MXV MAXIVENT. Automatic large capacity deaerator provided with manual air vent valve. Cast iron body and cover with epoxy finish. Max. operating pressure : 12 bar. Max. operating temperature : 115 C. Female air outlet connection : 3/8". MXV 0253020 3/4" 1 MXV 0253025 1" 1 MXV 0253032 1.1/4" 1 ERD EUROVENT Automatic /manual double deaerator with expansion vessel. Tropicalized sheet steel body. rass OT58 body. Max. pressure : 8 bar. Max. temperature : 115 C ERD 0253625 1" 1 ERD 0253640 1.1/2" 1 SA Air separator with 5 threaded instrument connections. Painted malleable cast iron body (ND 3/8" to1/2"). Female threaded connections. SA 0260125 1" 1 SA 0260132 1.1/4" 1 SA 0260140 1.1/2" 1 SA 0260150 2" 1 SA 0260165 2.1/2" 1 SA 0260180 3" 1 SAF Flanged air separator. Complete with female connection (3/4" for SAF ND 100 and 1" for SAF DIN 125) for installation of automatic deaerator MXV. Complete with counterflange, bolts and seals. SAF 0260200 100 1 SAF 0260225 125 1 SAF 0260300 200 1

AIR VENTS AIR AND DIRT SEPARATORS WATER DRAIN VALVES POWERVENT SCREWED Removal of air and dirt particles from heating systems ronze body with screwed SP Female end connections Max. pressure 8 bar. Max. temerature: 115 C 9 PV075 M15800 3/4" 1 PV100 M15801 1" 1 PV125 M15802 1-1/4" 1 PV150 M15803 1-1/2" 1 PV200 M15804 2" 1 POWERVENT FLANGED Removal of air and dirt particles from heating systems Welded steel body with flanged PN10 end connections Max. pressure 10 bar. Max. temerature: 121 C PV200F M15700 50mm 1 PV250F M15701 65mm 1 PV300F M15702 80mm 1 PV400F M15703 100mm 1 PV500F M15704 125mm 1 PV600F M15705 150mm 1 PV800F M15706 200mm 1 PV1000F M15707 250mm 1 238 Drain valve with stuffing box and hose fitting. 238 23814 1/4" 10 238 23838 3/8" 10 DRAIN COCKS Drain cocks with hose fittings 238 MO16902 1/2" 1 238 MO16903 3/4" 1 238LS MO16904 1/2" 1 238CAPILLARY MO16905 15mm" 1

OVERALL DIMENSIONS WATER DRAIN VALVES 10 290 Drain valve for boilers, with hose fitting, plug and chain. 290 29038 3/8" 10 290 29012 1/2" 10 290 29034 3/4" 10 RSM Adapter for radiators. Chrome-plated brass body. Sealed on radiator through O-ring. RSM 0258015 1/2" M x 3/8" F 100 TSM Closing plug for radiators. Chrome-plated brass body. Sealed on radiator through O-ring. TSM 0258115 1/2" M 100

OVERALL DIMENSIONS CHAPTER 228C 238C 11 E 12 19 31 C A 11 D ND A C D E 1/8 29 17 12 11 17 1/4 29 17 12 11 17 3/8 29 19 10 11 17 231C 24 VMM 39 8 31 14 ND A CH 1/8 24 5.5 14 1/4 24 6 14 3/8 26 7 17

OVERALL DIMENSIONS CHAPTER 12 PMC SMM ND A D CH 1/8 18 5.5 16 14 1/4 18 5.5 16 14 3/8 20 6 20 17 1/2 22 7 24 22 ND A D CH 1/8 26 5.5 16 14 1/4 26 6 16 14 3/8 28 6.54 21 19 1/2 28 7.3 25 22 MVD MV ND CH 1/4 19 3/8 19 1/2 22 ND CH 1/4 19 3/8 19 1/2 22

OVERALL DIMENSIONS CHAPTER MKL MV-SOL 13 2161C D MKV C A ND A C D 3/8 30 10 77 36 1/2 30 10 77 36 3/4 32 12 79 36 1 37 12 79 36

OVERALL DIMENSIONS CHAPTER 14 RIA MXV - 3/4" - 1" - 1.1/4" ND C CH 1/4 8 11 19 3/8 8 11 19 1/2 8 11 24 ERD A 49 SA h D D H L ND A L H h 1 60x50 94 153 26 1.1/2 60x60 104 191 32 ND A C L H 1 1/2 3/4 70 152 87 1.1/4 1/2 3/4 70 152 87 1.1/2 1/2 3/4 70 152 87 2 3/4 1 87 189 115 1.1/2 1 1 128 300 203 3 1 1 128 300 203

OVERALL DIMENSIONS CHAPTER SAF 238 15 A ND A L H 100 PN6 3/4 600 156 125 PN10 1 700 168 200 PN10 1 800 ND A 1/4 28 47 3/8 28 47 290 RSR 29 A ND A 1/8 25 60 1/2 30 75 3/4 40 90 ND KEY Ø22 ND 1/4 6 3/8 7 1/2 7

Watts Industries UK Ltd Grosvenor usiness Park, Evesham, Worcestershire, WR11 1GA, England Phone +44 (0) 1386 446997 - Fax +44 (0) 1386 41923 Email sales@wattsindustries.co.uk - www.wattsindustries.com