Enterprise Network Management System (NMS) Maintenance Release addresses the following issues:

Similar documents
ET9500 BEMS Interface Box Configuration Guide

SNMP dedicated to ORVALDI Solar Infini

Installation and Programming Manual Part: Building Network Interface Card Product: 4100ES

IBM CMM Quick Reference Guide

Fiorano ESB 2007 Oracle Enterprise Gateway Integration Guide

PowerChute TM Network Shutdown v4.0. User Guide. VMware

PowerChute TM Network Shutdown v3.1. User Guide. VMware

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11

Dominion PX TM. Frequently Dominion PX TM Asked Frequently Asked Questions. General Questions

Cloudprinter.com Integration

JUMO DSM software. PC software for management, configuration, and maintenance of digital sensors. Operating Manual T90Z001K000

GPI (Gas Pump Interface) with Cash Register Express - Integration Manual

Installing Proactive Monitoring for PowerCenter Operations 2.0 HotFix 1 on Solaris

1. Introduction Benefits How it works Tachograph Compatiblity Requirements For End Users

Note: If anything is damaged or missing, contact your customer representative immediately.

ContiFI - ContiFleetInspection -

ELD DRIVER GUIDE June 21, 2018

User s Manual. Suitable Products: Three phase grid tie inverter with energy storage Three phase off Grid inverter

Hours of Service ELD Administrator User Guide v3.6

MetaXpress PowerCore System Installation and User Guide

Envoy Communications Gateway

Chassis Profiles and Templates

MCS-BMS-GATEWAY STARTUP GUIDE Covers Model No. FPC-C35

TachoDrive key + TachoDrive Express software

INSTALLATION USER MANUAL

Installation and Operations Manual. Envoy Communications Gateway

Frequently Asked Questions: EMC Captiva 7.5

R11B EN R11A EN. RackCDU. Service Manual. Edition August 2016 Page 1 of 24 V /8

Motor Vehicle Processing

User Guide. PowerChute Network Shutdown v4.1 Standard D /2015

SolarPower. User Manual. Suitable Products: Three-phase grid-tie inverter with energy storage. Three-phase off-grid inverter

SolarPower. User Manual. Suitable Products: Three-phase grid-tie inverter with energy storage. Three-phase off-grid inverter

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Envoy Communications Gateway

NO PART OF THIS DOCUMENT MAY BE REPRODUCED WITHOUT PRIOR AGREEMENT AND WRITTEN PERMISSION OF FORD PERFORMANCE PARTS.

User Guide Electronic Logging Device

FieldMaster Logs. Administration and Best Practice Guide. Version 3.0 Revision A November 2017 TRANSFORMING THE WAY THE WORLD WORKS

Contents Getting Started with PrePass ELD...4 Starting a Trip...7 During a Trip Co-Driver Features... 14

TESLA VEHICLES PLUG-IN FOR HOMESEER VERSION 1.0.2

Acceptance Test Plan. Stake holder: Dawn Gulick Group members:

Envoy Communications Gateway , Rev 03

QUICK START GUIDE FOR ACCESS CONTROL BOARDS. DX Series Four Door TCP/IP Web Server Controller. Model: ACP-DXEL4

Hi-Z USB Wireless. Introduction/Welcome

TRITON ERROR CODES ERROR CODE MODEL SERIES DESCRIPTION RESOLUTION

WIRELESS BLOCKAGE MONITOR OPERATOR S MANUAL

Installation and Operations Manual. Envoy Communications Gateway

e-track Certified Driver Operating Manual

User manual Suppliers evaluation process

Error Code List for ecash & Nanocash

Envoy Communications Gateway

VFD. Variable Frequency Drive

Network Installation. July 2008 CONTENTS

Omnitracs HOS Host 4.3v External Release Notes

TomTom WEBFLEET Contents. Let s drive business TM. Release note

EPAS Desktop Pro Software User Manual

NAVMAN WIRELESS OFF ROAD TRACKER

Logbook Selecting logbook mode Private or business mode Administrating logbook records Reporting... 33

TachoReader Combo Plus

DA-ST512 (Suspension Calibration Application) User s Manual

Redbird Insight User Guide

PQube 3 Modbus Interface

GPK for Design and Rating of Industrial Gearboxes

Advanced User Manual

USER S GUIDE LandAirSea 7100 Real Time GPS Tracking System

ZT-USB Series User Manual

AXINET BATTERY MANAGEMENT SYSTEM. system for monitoring and controlling the performance of charger stations

Release Enhancements GXP Xplorer GXP WebView

Veritas CloudPoint Release Notes. Ubuntu

Integration of PowerChute Business Edition with EcoStruxure IT

User Manual SMA FUEL SAVE CONTROLLER 2.0

Vanpool Regional Administration

TS508. QuickStart Guide Registration. This Tool Must Be Registered To Download Free System Updates. 7 8 Captcha code

EVlink Charging Stations Commissioning Guide

Mitsubishi. VFD Manuals

2004, 2008 Autosoft, Inc. All rights reserved.

RS232. CAN. Integration with Tachograph Continental VDO DTCO

Issue 2.0 December EPAS Midi User Manual EPAS35

Huf Group. Your Preferred Partner for Tire Pressure Monitoring Systems. IntelliSens App

ELD Compliant Driver Operating Manual

Index. Calculated field creation, 176 dialog box, functions (see Functions) operators, 177 addition, 178 comparison operators, 178

PowerChute Network Shutdown v4.2 Release Notes

PowerCommand 500/550 Remote Monitoring System

WEM-MX-333mV. Integrated Meter Installation Guidelines

Tranax Error Code Summary

ZEPHYR FAQ. Table of Contents

Industrial Renewable Energy. 4-Port 10/100/1000T 802.3at PoE+ Managed Ethernet Switch BSP-360. Quick Installation Guide

QuickServer Industrial Protocol Gateway

Solution / Instructions

GFX2000. Fuel Management System. User Guide

Appendix 3 V1.1B Features

There is a Certification menu option that indicates that the mobile APP, mobile device used were self-certified according to federal requirement.

Using Apollo Solar Remote Monitoring Software

Tranax Error Code Summary

SOLAR SMART. 12/24V 20Amp MPPT Solar Charge controller with Ethernet

Quick Setup Guide. WARNING! Connect this product to an AC power source whose voltage is within the range specified on the product's nameplate.

Dynojet Research, Inc. All Rights Reserved. Optical RPM Sensor Installation Guide.

BX Licensing System. Instructions for Request and Use of BX Software Add-Ons

An ISO 9001:2008 Registered Company

Videosystem CAR-READER

Security. Hardware Specifications. Editor: Stephen Satchell. Version Security Hardware Specification version i Copyright 2012 INE, Inc.

Transcription:

Contents 1) Release Summary...1 2) Enhancement Requests...6 3) Important Notes and Known Limitations...7 4) Platforms Supported...9 5) Installation Notes...9 6) Uninstallation Notes...10 1) Release Summary Enterprise Network Management System (NMS) Maintenance Release 10.4.1 addresses the following issues: Access Control Q01106481 A user with read-only access was able to modify Fault Summary preferences. Q00976586 Q01114977 Q01153527 Q01187768 Q01190446 With AccessControl On, a user cannot activate a seed unless the root user / Administrator has assigned the implicit view domain of the seed to the user. Appropriate warning and error messages were not displayed for this condition. A router was configured to use a static route as back-up for a number of on-demand circuits. The static route was being displayed in the Internet view as a separate entity. When the General > Comm Strings > All Database discovery preference was selected, an invalid character appeared in the toprt log file. On an ERS 8600, inexplicable MIB errors were encountered when dislink was run. Dual homed (DH) ERS 8600 nodes were displayed as brown, indicating a fault condition when one did not exist. Q01205017 Links between two OPEs or between an OPE and an ERS 8600 were not being discovered. Q01226854 Q01228834 Q01244338 Devices were placed in the wrong subnet folder. Subnets were not discovered using a routerless discovery. Subnets were not discovered or devices were placed in the wrong subnet folder. 1 of 11

Q01251037 Q01264538 Q01273158 Q01276067 Q01287058 Q01287179 A network was not discovered when a seed was defined with a specific IP address range. View domains created by a non-root user did not persist across sessions. When the VLAN folder view was changed to the physical layer, the VLAN folder appeared to be empty. A second discovery was required to discover new VLANs. When an ERS 8600, an ESU 1800, and an ESU 1850 were deployed in a Optical Ethernet configuration, an issue with the ViewDomain caused problems in a number of applications (InfoCenter, Device Inventory, Fault Summary) were observed. The broadcast address of an Ethernet Routing Switch 1424 was being used as the IP_label. Q01378274 The end nodes connected to a ERS 8600 version 4.0.2.0 and a 8648 GTR card were not discovered. Device Integration Toolkit Device Integration Toolkit Device Integration Toolkit Q01104240 Q01253389 Q01312622 Q01194933 Q01213443 Q01228530 Q01273053 Q01310203 Q01310241 Newer agent versions were available on the Nortel site but they were not detected. (Related: Q01154551, Q01253389) The Update component feature (Tool > Update component) did not always identify all the new DIT packages available from the Nortel site. Java Device failed to open when the user tried to launch it using the context (right-click) menu of the IP address of a switch. On a standalone client running Windows 2000 or 2003, a java error occurred when devices were exported to a.csv file. The wrong agent version was displayed for a CS 1000E Call Server. When the asset information for an ERS 8600 DH-ring was viewed, the serial number and HW Rev were missing. When the asset information for an ESU 1850 was viewed, information for port 1 was wrong and was missing for other ports. A Business Policy Switch (BPS) stack appeared as one device. The BPS stack is designed to appear as one device. An Ethernet Switch 470 stack appeared as one device. The ES 470 stack is designed to appear as one device. disdevice Q01299618 Users without appropriate access permissions were able to discover devices with disdevice. 2 of 11

dislink Q01274281 Dislink discovered devices outside the range of the assigned view domain. Expanded View Q01073388 The text shown in the blue bar at the bottom of the About Expanded View menu option did not fit the window and / or was difficult to read. Expanded View Q01235537 For an Ethernet Switch 470 48T PWR v3.6.2, when the Gigabit module (gbic) was installed and the link was up, only the shared copper port LEDs were on when the gbic was a fiber module. Expanded View Q01235548 For an Ethernet Switch 470 48T PWR v3.6.2, both fiber and copper shared ports were displayed as active when fiber ports were up. Fault Correlator Q01150108 The bsnconfigrationsavedtonvram v3 trap from BayStack devices was not converted to a fault. Fault Correlator Q01317935 OtmOpenxxxxx traps received from the Communication Server (rebranded from OTM) were not correlated into faults. Fault Script Q01326431 On VPN Routers (formerly Contivity Extranet Switches), scripts for some secure router faults did not execute. Fault Summary Q01160046 With an Ethernet Switch 470 v4.2 or an ES v4.4, the Mac address was not provided in the fault description. (Reference: Q00888812) Fault Summary Q01324426 On an ERS 470 24T/48T, the slot/port information of a link that goes up/down was shown incorrectly. Fault Summary Q01341063 Slot and port information was not displayed for a Link Up / Link Down fault. Fault Summary Q01344317 Traps from an ERS 8600 on a particular subnet were not reported. Fault Summary / Fault Script Fault Summary / Trap Server Fault Summary / Trap Server Q01300997 Q01190481 Q01245890 On an ERS 8600, the F_Generic_3_LINK_DOWN_RFC1573_2_3_new generic fault was not available as a menu option for fault scripts. Given that the trap-sending IP address of a device has been discovered, then all traps from that IP address are received and processed by Enterprise NMS, even if a specific interface is not within the seed range. When InfoCenter determined the appropriate fault color to assign to the device, all interfaces were considered. However, the faults from the specific interface did not appear in Event Browser because the view domain did not include the IP address of the specific interface. See also Q01245890. It appeared that traps were not being received from ESUs attached to an ERS 8600 DH-ring. See also Q01190481. 3 of 11

InfoCenter Q01064459 Infocenter stopped functioning when you selected No for managing a device function. InfoCenter Q01100179 When a customer folder was created using the OE ring filter, the folder was not populated and appeared empty. InfoCenter Q01299619 On a Windows client, setting the Options > Set Preferences > Global > Display DNS Names did not seem to work. InfoCenter Q01344305 An ESU in a particular subnet was not discovered. OmniView Q01276423 Java exception errors occurred when OmniView statistics panes were refreshed automatically (as a result of a polling interval expiring). OmniView Q01299606 Beta-Delta > Second, Peak Delta > Second, Average Delta > Second panes were not working OmniView Q01299608 The Pane > Export function only exported total values, regardless of the values currently displayed. OmniView Q01299609 Graphs did not plot data correctly. OmniView Q01299610 With an ERS 8600, the defined panes for blade type did not match the blade hardware types. OmniView Q01299612 For 8672 ATM blades on ERS 8600 switches, no values are provided for ATM statistics under "Ports-by-Slot" for "ATM-PVC" and "ATM 1483 Elan". OmniView Q01299613 On an ERS 8600, the IP Routing > IP > Circuitless pane listed all IP addresses, not just the circuitless IP addresses. OmniView Q01299614 IPX addresses were displayed in decimal, not HEX. OmniView Q01299616 On BayRS routers, under Router > Table > Protocol IPX, the Route Table, SAP Table, and Interface Table panes were empty. OmniView Q01302022 When the SNTP Protocol pane was opened, the pane was empty and OmniView closed. OmniView Q01302112 On a Business Policy Switch 2000 v3.1.5.07, the Port Details > VLAN ID pane used HEX format. OmniView Q01302125 On a Business Policy Switch 2000 v3.1.5.07, the "Name", "Port Members", "Active Members", "Static Members" and "Not Allow To Join Members" values on the Vlan > Basic Vlan pane were displayed in HEX. OmniView Q01302328 On a Centillion 100 MCP v4.2.1, the fields on the Port-by-Slot > Slot 1 (ATM MCP) > Activity pane applied to Ethernet not ATM. No stats were displayed as the fields did not match the hardware type. (See also Q01302356.) 4 of 11

OmniView Q01302356 See Q01302328. OmniView Q01302393 On a System 5000BH MCP v4.2.1, the "ELAN Name" values on the LANE Services > LAN Emulation Server > Profile pane were displayed in HEX. OmniView Q01303942 On an ES 470 48T v3.5.1.05, the "VLAN ID" values on the Port Details > VLAN Information pane were displayed in HEX. OmniView Q01303960 On an ES 470 48T v3.5.1.05, the "Name", "Port Members", "Active Members", "Static Members" and "Not Allow To Join Members" values on the Vlan > Basic Vlan pane were displayed in HEX. OmniView Q01303969 On an ES 470 48T v3.5.1.05, the "VLAN ID" values on the Port Details > VLAN Port Information pane were displayed in HEX. OmniView Q01303981 On an ES 470 48T v3.5.1.05, the "Unassigned Ports" values on the Spanning Tree > Spanning Tree Group Information pane were displayed in HEX. OmniView Q01303988 On an ES 470 48T v3.5.1.05, when the Rapid Spanning Tree Protocol > Rapid Spanning Tree Extensions pane was opened, the pane was empty and OmniView closed. OmniView Q01303998 On an ES 470 48T v3.5.1.05, when the Multiple Spanning Tree Protocol > Multiple Spanning Tree Group Information pane was opened, the pane was empty and OmniView closed. OmniView Q01304007 On an ES 470 48T v3.5.1.05, when the SNTP Protocol > Configuration pane was opened, the message "No Data in Pane" was displayed. OmniView Q01304016 On an ES 470 48T v3.5.1.05, when the SNTP Protocol > Status pane was opened, the message "No Data in Pane" was displayed and OmniView closed. OmniView Q01309762 On a BayRS router, when the Circuit Summary > Protocols > Protocol IP > Traffic Information pane was opened, the pane was empty. OmniView Q01309764 On a BayRS router, the Last Change value on the MIB2 > Interface > Status/Profile pane was incorrect. OmniView Q01309775 On a BayRS router, when the (VNR) Circuit Summary > Protocols > Bridge > Learning Bridge Info pane was opened, the pane was empty. OmniView Q01312589 On an ERS 5500, the Port activity pane did not show unit/port information. OmniView Q01319092 On an ESU 1800 and an ESU 1850, response was very slow for the QOS > 802.1p User Priority pane.. 5 of 11

OmniView Q01334069 When panes were opened and the Display Label (Options->Display Label) was changed from Display Default Name to Display Sys Name, some operations and displays did not work properly. OmniView Q01339074 The Belongs to option remained active for a device even after the command was executed on the device and its subnetwork was displayed. OmniView / InfoCenter Q01206918 For an ESU 1800 and an ESU 1850, some port numbers were unreadable in OmniView; for an ERS 8600, a port number was unreadable in the VLAN folder. Syslog Q01217304 Syslog registration was not supported on VPN Router 221 and VPN Router 251. Syslog Q01319433 Syslog messages from Access Point 7220s were not displayed. Transport Domain Continuity Q01074249 Some columns displayed information in the wrong (HEX) format. Trap Registration Q01285048 On an ERS 8600 v3.7.11, the Enterprise NMS server was unable to register as trapreceiver. Trap Registration Q01309214 Auto trap registration did not work on an ERS 1600 v2.1.0. Trap Registration Q01344208 AutoTrap Registration failed with ESU 1850 v3.0.0 or later. Trap registration / Management state Q01229721 An Ethernet Services Unit (ESU) 1800 could not be placed in the Unmanaged state and trap registration could not be de-selected. Username Q01226274 The username initial caused problems with some Enterprise NMS applications. 2) Enhancement Requests Enterprise NMS Maintenance Release 10.4.1 addresses the following enhancement requests: Tool CR ID Enhancement Fault Summary / Fault Script Q01291587 You can create fault scripts on the Ethernet Switch 470. InfoCenter Q01238800 If you access the Enterprise NMS server through a web browser, you can launch an application from within InfoCenter without reentering your user name and password. InfoCenter Q01282143 You can use a dot in a user name. For example: john.buck 6 of 11

Tool CR ID Enhancement InfoCenter Q01261719 If you access the Enterprise NMS server through a web browser, you can launch an application from within InfoCenter without reentering your user name and password. OmniView Q00884339 Device counters are zeroed when they are cleared. OmniView Q01266157 Resized windows maintain their new size after a new polling interval starts. OmniView Q01266258 A Removed Entity item has been added to the Menu > File options. This option allows you to remove an entity from the Navigation pane. 3) Important Notes and Known Limitations 3.1) Enterprise NMS 10.4 must be installed prior to installing the Enterprise NMS Maintenance Release 10.4.1. 3.2) CR: Q01418548, CR: Q01420171 One or more blank command lines can be inserted in the Modify Application Launch window when Enterprise NMS Maintenance Release 10.4.1 is installed. The blank lines can overwrite existing launch definitions with the result that the corresponding applications are no longer available on the right-click menu. Workaround: 1. Start Application Launch (InfoCenter: Admin > Application Launch). 2. Locate the blank command line in the Application List of the Modify Application Launch window. 3. Delete the blank line. 4. Reenter the original command line. 3.3) Fault Summary on a client running Enterprise NMS 10.4 does not operate in conjunction with a server that is running Enterprise NMS Maintenance Release 10.4.1. The converse is also true. Nortel recommends that you update both server and client machines. 3.4) CRs: Q01344317, Q01190481, Q01245890 For any device, all traps and faults (for all interfaces) are displayed when any interface of the device is in the view domain assigned to the user. 3.5) CRs: Q01302022, Q01319092, Q01309775, Q01299613, Q01312589, Q01309762, Q01302393, Q01299616, Q01302356, Q01299610 The fixes for these CRs can cause installation time to increase by up to one hour. An option to skip these fixes is provided during installation. 7 of 11

3.6) Enterprise NMS Maintenance Release 10.4.1 includes several new agents that are installed using the Device Integration Toolkit. Install the new agents before installing Enterprise NMS Maintenance Release 10.4.1 to avoid overwriting enhancements provided by the Enterprise NMS Maintenance Release 10.4.1. 3.7) When you create a new discovery seed, Enterprise NMS creates and maintains a view domain for this seed automatically. In Enterprise NMS Maintenance Release 10.4.1, the default IP range of this view domain is 0.0.0.0 to 255.255.255.255. To define a specific IP range for this view domain, use > Settings > Enter Seed Specification > Advanced. Alternatively, you can create a new view domain using > Settings > Enter view domain specification. 3.8) CR: Q01380118 If a discovery is stopped manually ( > Discovery > Stop Discovery) and is closed before the stop notification is received, the seed is not removed from the discovery queue and the discovery continues. Workaround: If a discovery is stopped, wait for the stop notification before closing. 3.9) CR: Q01391822 If a view domain is created when Access Control is off, the range of the view domain changes when Access Contol is turned on. To reestablish the view domain: 1. Ensure that Access Control is on. 2. Launch. 3. Navigate to Settings > Enter Seed Specification. 4. Select a seed. 5. Click Apply. 6. Repeat for all seeds. Workaround: Only create view domains when Access Control is on. 3.10) CR: Q01392969 When a view domain is created by the Administrator and assigned to a user and that user opens Fault Summary, the Fault Summary report can have many blank lines between faults. This causes the report to paginate poorly: a large blank space does not indicate the end of the report. Workaround: Ensure that you have scanned to the end of the report. 8 of 11

4) Platforms Supported Server: Windows 2000; Windows 2000 Advanced Server with Service Pack 4; Windows 2003 Enterprise Server with Service Pack 1 Client: Windows XP Professional with Service Pack 2; Windows 2000 Professional with Service Pack 4 5) Installation Notes Enterprise NMS Maintenance Release 10.4.1 applies to both "Client-Server" and Client-Only installations of Enterprise NMS 10.4. Disk space requirements: Client-Server: 50 MB Client-Only: 5 MB To install Enterprise NMS Maintenance Release 10.4.1: 5.1) Login in as user Administrator. 5.2) Download the enms1041_win.zip archive file from the Nortel web site to a directory on the target Enterprise NMS 10.4 server, or to a server with network share capability. Download path: http://www.nortel.com/ > Support & Training menu > Technical Support item > Software Downloads item > Browse product support tab > Products A-Z tab > E > Enterprise Network Management System entry > Software link. 5.3) Extract the files to the directory to which the files were downloaded. If you are using WinZip: verify that the all files and use folder names options are selected verify that the permissions for the extracted files are set to read, write, and execute before extracting the files, enter the path to the directory to which the files were downloaded. 5.4) Stop all topology processes ('toprt', 'topst', 'topdt', 'protur', 'protmr', 'protfr'). To stop the processes, use: > Discovery > Stop Discovery 5.5) Exit/Close all ENMS client applications (examples: InfoCenter, Fault Summary, Expanded View). 9 of 11

5.6) Use Task to check for any Enterprise NMS processes that are running and End Task any that are. 5.7) If Enterprise NMS is integrated with an umbrella management platform (UMP) such as IBM Tivoli NetView or HP OpenView Network Node, Nortel recommends that you stop all UMP daemons. 5.8) Change directory (cd) to: <directory>/mswin32/cdrom/p1041/ where <directory> is the directory to which the Enterprise NMS Maintenance Release 10.4.1 files were downloaded and extracted. 5.9) To install Enterprise NMS Maintenance Release 10.4.1, enter: install1041.bat 5.10) When installation is complete and Enterprise NMS is installed with a UMP, start all UMP daemons if they were stopped previously. 5.11) When installation is complete or the UMP daemons have restarted, generate a list of the Enterprise NMS services that are running. Enter: optstatus fe The optstatus fe command generates a message if a service fails to start. Use Service Control to start the service. 6) Uninstallation Notes This procedure uninstalls Enterprise NMS Maintenance Release 10.4.1 and the system reverts to Enterprise NMS 10.4. To uninstall Enterprise NMS Maintenance Release 10.4.1: 6.1) Login in as user Administrator. 6.2) Stop all topology processes ('toprt', 'topst', 'topdt', 'protur', 'protmr', 'protfr'). To stop the processes, use: > Discovery > Stop Discovery 6.3) Exit/Close all ENMS client applications (examples: InfoCenter, Fault Summary, Expanded View). 10 of 11

6.4) Use Task to check for any Enterprise NMS processes that are running and End Task any that are. 6.5) If Enterprise NMS is integrated with an umbrella management platform (UMP) such as IBM Tivoli NetView or HP OpenView Network Node, Nortel recommends that you stop all UMP daemons. 6.6) Change directory (cd) to: %LNMSHOME%\p1041 6.7) Enter: uninstall1041.bat or install1041.bat -u 6.8) When installation is complete and Enterprise NMS is installed with a UMP, start all UMP daemons if they were stopped previously. 6.9) When installation is complete or the UMP daemons have restarted, generate a list of the Enterprise NMS services that are running. Enter: optstatus fe The optstatus fe command generates a message if a service fails to start. Use Service Control to start the service. 2006 Nortel Networks, Inc. All rights reserved. 11 of 11