SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

Similar documents
TS880 AUTOMATIC TRANSFER SWITCHES

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

SERIES TS AMP AUTOMATIC TRANSFER SWITCHES

Transfer switch OTEC and OTECSE open transition

4-in-1 MOTORS ONE SIMPLE CONNECTION

OTEC Transfer switch open transition

MULTIFIT MOTOR SPECIFICATIONS FEATURES

OTPC-SE Service entrance transfer switch open transition

Transfer switch OTEC open or delayed transition

MEDIUM VOLTAGE PRODUCT CAPABILITIES OVERVIEW

Full Complement Cylindrical Roller Bearings

Quick Start Guide TS 910 & TS 920

ASCO SERIES 185 Power Transfer Switches

Lift Truck Replacement Chain

Quick Start Guide TS 910

Zenith ZTGSE/ZTGDSE. GE Energy Digital Energy. Service Entrance Rated Automatic Transfer Switches. Introduction. Features and Benefits

SYSTEM PLAST NEW CURVE CONCEPT

Unit Material Handling Conveyor Solutions

Unit Material Handling Conveyor Solutions

Specification Guide. for RMAX. Direct Replacement. AC Low Voltage. Power Circuit Breakers

Zenith ZTX. GE Energy Digital Energy. Automatic Transfer Switch

GROVE GEAR PRODUCTS BROCHURE

Transfer switch GTEC open or delayed transition

CHPC Transfer switch closed transition

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

Transfer switch OHPC open or delayed transition

Think you ve reached all the low hanging fruit for energy efficiency in your facility?

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

DIVISION 26 ELECTRICAL SECTION CIRCUIT BREAKERS

Section SWITCHBOARDS. Introduction. Part 1 - General. Related Work

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

BTPC Bypass isolation transfer switch open or closed transition

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

CONTROLLIX CORPORATION CONTROLLIX.COM LOW VOLTAGE AUTOMATIC SWITCH CAPACITOR BANK SPECIFICATIONS

Transfer switch OTPC open, closed, or delayed transition

Zenith ZBTS/ ZBTSD/ZBTSCT

Design Standard. Purpose: Design Standard:

www. ElectricalPartManuals. com Systems Pow-R Breaker Transfer Switches Technical Data Page 1

SECTION PANELBOARDS

University of Houston Master Construction Specifications Insert Project Name

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Low Voltage Switchgear Type WL Low Voltage Metal-Enclosed Switchgear

BUSWAY Low Voltage (Pow-R-Flex)

Series Amp System 2000 Generator Control

50,000 cycles minimum, resistive, inductive, tungsten filament lamp load (Fed Spec) 1.753" Depth x " Width x 2.375" Height

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Experience the Difference Aerospace and Specialty Bearings

NORTH CAROLINA SHERIFFS ASSOCIATION

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

OTPC Transfer switch open and closed transition

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

SECTION MOTOR CONTROL

ASCO Low Voltage Automatic Transfer Switch Systems

Solar Power Switchgear & Energy Storage Renewable Energy Systems

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SPECIAL SPECIFICATION 5066 Packaged Engine Generator System

GTEC Transfer switch Open transition

FLORIDA SHERIFFS ASSOCIATION & FLORIDA ASSOCIATION OF COUNTIES

GTEC Transfer switch open transition

1. The term "withstand" means "the unit will remain in place without separation of any parts from the device when subjected to the seismic forces.

SEALED SPHERICAL ROLLER BEARING

A. Submit manufacturer's literature and technical data before starting work.

Drives for the Metals Industry

Fused Coordination Panelboard

ALL PRODUCTS CATALOG

Residential and Light Commercial Features Overview

Three-Phase Pole Mounted Recloser

FLORIDA SHERIFFS ASSOCIATION & FLORIDA ASSOCIATION OF COUNTIES

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Low Voltage Automatic Transfer Switch Systems

Diesel generator set QSK60 series engine

IDENTIFYING DISC COUPLING FAILURES COUPLING FUNDAMENTALS

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

F-Series. Circuit Breaker

Horizontal Circuit Switchers

Horizontal Circuit Switchers

SUBSTATION VACUUM CIRCUIT BREAKER (15.5KV)

SUBSTATION VACUUM CIRCUIT BREAKER (38KV)

SUBSTATION VACUUM CIRCUIT BREAKER (25.8 / 27KV)

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

F-Series. Circuit Breaker

A. Work Included: Provide low voltage switchboard work as shown, scheduled, indicated, and as specified.

Selection and application guide

Diesel generator set QSK95 series engine

WARREN COUNTY, N.Y. M/E REFERENCE

Spark-ignited generator set

Diesel generator set QST30 series engine

EXPERIENCE, INNOVATION AND CLOSE COOPERATION WITH LEADING INTERNATIONAL COMPANIES.

Bypass/Isolation Switches RTS-03 SERIES

Quik-Spec Coordination Panelboard Specifications

GENERAL INDUSTRY WIND MARINE METALS & HEAVY DUTY

V-BELT DRIVES AND BEARINGS

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Extra Heavy Duty Modular Belts 2508 & 2630 Series

Publication No.: PSG

MARATHON SLA SERIES CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW

Diesel generator set C17D5T series

MARATHON HLA SERIES HLA CAST ALUMINIUM MULTI-MOUNT THREE PHASE MOTORS SIZES , KW

Transcription:

SERIES TS 840 100-800 AMP AUTOMATIC TRANSFER SWITCHES AG R I C U LT U R A L

THOMSON POWER SYSTEMS TS 840 AUTOMATIC TRANSFER SWITCHES OFFER THE FOLLOWING: ENCLOSED CONTACT POWER SWITCHING UNITS Fully enclosed silver alloy contacts provide high withstand rating & 100% continuous current rating. 3 cycle short circuit current withstand. Completely isolated utility and generator side power switching units. Power switching units can incorporate overcurrent protection, allowing cost savings in upstream devices. Not damaged if manually switched while in service. RELIABLE MOTOR-OPERATED TRANSFER MECHANISM Heavy duty brushless gearmotor and operating mechanism provide mechanical interlocking and extreme long life. Safe manual operation permits operation under adverse conditions. SUPERIOR SERVICEABILITY All mechanical and control devices are visible and front accessible. All control wires and power busses are front-accessible there are no wires or connections which require removal of the transfer switch from its enclosure for servicing. CONTROL FEATURES TSC 80 micropocessor based controller NEMA 3R enclosure for outdoor weatherproof applications Isolation plug permits disconnecting control circuits from all power sources. QUALITY ASSURANCE ISO 9001 Registered SEISMIC CERTIFICATION TS 840 ATS is certified for installation and operation per the following requirements: IBC 2006 Section 13, Occupancy Category IV ASCE7-05 Region 3 (minimum SS=342%) SAFETY STANDARDS UL 1008 Automatic Transfer Switches for use in Emergency Systems CSA C22.2 No. 178 Automatic Transfer Switches WARRANTY 2 year limited warranty included Thomson Power Systems TS 840 series of Automatic Transfer Switches employ two mechanically interlocked enclosed contact power switching units and a microprocessor based controller to automatically transfer system load to a generator supply in the event of a utility supply failure. System load is automatically re-transferred back to the utility supply following restoration of the utility power source to within normal operating limits. TS 840 series automatic transfer switches provide an open transition break-before-make transfer system with neutral position delay to ensure adequate voltage decay to prevent out of phase transfers. TS 840 Automatic Transfer Switches are specifically designed and certified by UL 1008 and CSA C22. No. 178 nationally recognized safety standards for use in emergency systems at 240VAC. High withstand current ratings have been achieved using 3 cycle short circuit testing in accordance with UL 1008/CSA178 standards. This allows flexible system over current coordination by utilization of non-series rated upstream protective devices. TS 840 ATS models can be utilized in light industrial, telecom and agricultural applications which legally require automatic standby power. TS 840 series of Automatic Transfer Switches are available in 2 basic model types: Standard ATS and Service Entrance Rated (SE). Service Entrance Rated Automatic Transfer Switches incorporate an isolating mechanism and over current protection on the utility supply thereby removing the need to have a separate, upstream circuit breaker/disconnect switch from the transfer switch. This unique Service Entrance Rated ATS design is incorporated into a standard sized automatic transfer switch enclosure providing a space-saving, cost effective solution for most applications. TS 840 SE Service disconnect operation is very simple and ensures a high level of safety for system maintenance personnel when performed. Normal operation and performance of the automatic transfer switch is unaffected by the Service Entrance feature. TS 840 series automatic transfer switches use a type TSC 80 microprocessor based controller which provides all necessary control functions for fully automatic operation.

WITHSTAND CURRENT RATINGS (ALL MODELS) MODEL RATED CURRENT (AMPS) MAXIMUM VOLTAGE WITHSTAND CURRENT RATING AMPS (RMS) 1 With Upstream Circuit Breaker Protection With Upstream Fuse Protection @240V @240V FUSE TYPE TS 84xA - 0100 100A 240 65,000 100,000 T,J TS 84xA - 0150 150A 240 65,000 100,000 T,J TS 84xA - 0200 200A 240 65,000 100,000 T,J TS 84xA - 0250 250A 240 65,000 100,000 T,J TS 84xA - 0400 400A 240 65,000 100,000 T,J TS 84xA - 0600 600A 240 65,000 100,000 T,J TS 84xA - 0800 800A 240 65,000 100,000 Consult Factory ENCLOSURE DIMENSIONS/CABLE TERMINALS (NEMA 3R, ASA #61 GRAY) AMPERAGE NUMBER OF POLES DIMENSIONS INCHES (mm) 1 SHIPPING TERMINAL RATING 3 WEIGHT HEIGHT WIDTH DEPTH lbs (kg) QTY RANGE 4 (PER PHASE) 100A 2,3 31.1 (790) 22.3 (566) 14.0 (356) 143 lbs (65) 1 #14-1/0 100A w/dist 2 2,3 43.1 (1095) 34.3 (871) 13.0 (330) 233 lbs (106) 1 #14-1/0 150A 2,3 31.1 (790) 22.3 (566) 14.0 (356) 143 lbs (65) 1 #2-4/0 150A w/dist 2 2,3 43.1 (1095) 34.3 (871) 13.0 (330) 233 lbs (106) 1 #2-4/0 200A 2,3 31.1 (790) 22.3 (566) 14.0 (356) 143 lbs (65) 1 #6 350 mcm 200A w/dist 2 2,3 43.1 (1095) 34.3 (871) 13.0 (330) 237 lbs (108) 1 #6 350 mcm 250A 2,3 35.1 (892) 27.3 (693) 14.0 (356) 172 lbs (78) 1 #6 350 mcm 250A w/dist 2 2,3 43.1 (1095) 34.3 (871) 13.0 (330) 251 lbs (114) 1 #6 350 mcm 400A 2,3 43.1 (1095) 34.3 (871) 13.0 (330) 227 lbs (103) 2 2/0 500 mcm 400A w/dist 2 2,3 63.1 (1603) 40.8 (1036) 14.5 (368) 354 lbs (161) 2 2/0 500 mcm 600A 2,3 46.1 (1171) 36.3 (922) 14.5 (368) 248 lbs (113) 2 2/0 500 mcm 600A w/dist 2 2,3 63.1 (1603) 40.8 (1036) 14.5 (368) 358 lbs (163) 2 2/0 500 mcm 800A 2,3 48.1 (1222) 37.8 (960) 18.0 (457) 309 lbs (140.4) 3 2/0 500 mcm 800A w/dist 2 2,3 63.1 (1603) 40.8 (1036) 18.0 (457) 422 lbs (192) 3 2/0 500 mcm 1 Enclosure dimensions are for reference.(do NOT USE FOR CONSTRUCTION) 2 Enclosures for models with Distribution Breaker Options (Dist 2 or Dist 4) 3 All cable connections suitable for copper or aluminum 4 Optional terminal ratings are available in some models Consult Thomson Power Systems

STANDARD FEATURES (With TSC 80 Controller) Load on Utility & Load on Generator Lights Utility & Generator Source Available Lights Three Phase Voltage Sensing on Utility & Generator Sources Under Frequency Sensor on Generator Source Engine Start Delay Timer 0-60 sec. Engine Cooldown Delay Timer 0-30 min. Engine Warm-up Timer 0-60 sec. Neutral Position Delay 0-60 sec. Utility Return Timer 0-30 min. Engine Start Contact (10A, 120/240 VAC res. Form B) Exercise Timer (On or Off Load, Fixed 30 min.) Auxiliary Contact - Utility side (10A, 120/240 VAC res. Qty 1, Form C) Auxiliary Contact - Generator side (10A, 120/240 VAC res. Qty 1, Form C) Local Utility Power Fail Simulation Test Pushbutton Provision for Remote Load Test/Peak Shave Switch Input NEMA 3R Enclosure Solid Neutral Storage Temperature: -40 o C to 70 o C (-40 o F to 158 o F) Operating Temperature: -40 o C to 50 o C (-40 o F to 122 o F) Humidity: 95% non-condensing, maximum ORDERING INFORMATION When placing an order, specify the following 21 digit ATS MODEL CODE as per the features and applications described below. 1 2 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 T S 8 4 1-3. SERIES 12. APPLICATION 18. UTILITY SWITCHING DEVICE TS - TRANSFER SWITCH A - STANDARD K - MOLDED CASE SWITCH (100-800A) B - SERVICE ENTRANCE M - MOLDED CASE SWITCH C/W THER-MAG 4 & 5. MODEL TRIP (100-200A) 84-840 SWITCH 13. OPERATION TYPE N - MOLDED CASE SWITCH C/W ELECTRONIC 1 - OPEN TRANSITION TRIP (250-800A) 6. POLES 2-2 POLE 14. SAFETY STANDARDS 19. GENERATOR SWITCHING DEVICE 3-3 POLE A - UL 1008 (Service Entrance) K - MOLDED CASE SWITCH (100-800A) B - CSA C22.2 NO 178 M - MOLDED CASE SWITCH C/W THER-MAG 7. CONFIGURATION TYPE C - UL 1008 / CSA 178 TRIP (100-200A) A - ATS N - MOLDED CASE SWITCH C/W ELECTRONIC 15. VOLTAGE TRIP (250-800A) 8-11. AMPERAGE 1Ø 3 WIRE 0100 D - 120/240 20. POWER CONNECTIONS 0150 3Ø 4 WIRE (GROUNDED NEUTRAL) A - STANDARD 0200 E - 120/208 0250 G - 120240 (DELTA) 21. ATS CONNECTION CONFIGURATION 0400 A - STANDARD 0600 16. CONTROLLER 0800 1 - TSC80 17. ENCLOSURE TYPE D - NEMA3RSD, ASA #61 GRAY E - NEMA3RDD, ASA #61 GRAY (800A Only)

AVAILABLE IN STOCK The following standard Automatic Transfer Switch models are available from stock: MODEL AMPERAGE 2 POLE (SINGLE PHASE, 3 WIRE WITH NEUTRAL) STANDARD ATS SERVICE ENTRANCE RATED ATS TS842A0200A1AD1DKKAA 200A 120/240V TS842A0200B1AD1DNKAA 200A 120/240V TS842A0250A1AD1DKKAA 250A 120/240V TS842A0250B1AD1DNKAA 250A 120/240V TS842A0400A1AD1DKKAA 400A 120/240V TS842A0400B1AD1DNKAA 400A 120/240V TS842A0600A1AD1DKKAA 600A 120/240V TS842A0600B1AD1DNKAA 600A 120/240V VOLTAGE TSC 80 CONTROLLER NEMA 3R ENCLOSURE OPTIONAL FEATURES (Specify separately from ATS MODEL CODE when ordering) CODE Dist 2 Dist 4 Dist 6 SDM TS-H1 TS-H2 DESCRIPTION Load Distribution Breakers (Qty 2, 200A, 2 Pole Only) Load Distribution Breakers (Qty 4, 200A, 2 Pole Only) Load Distribution Breakers (Qty 6, 200A, 2 Pole Only) LCD Service Display Module - Displays TSC 80 Controller Settings and Timer Adjustments - Plug in Connector and Cable Enclosure Strip Heater c/w Thermostat (120VAC External Power Source Required) Enclosure Strip Heater c/w Thermostat (Internally Powered from ATS Load)

Thomson Power Systems 9087A - 198th Street Langley, BC, Canada V1M 3B1 Customer Service: 604-888-0110 info@thomsonps.com www.thomsonps.com NOTE: Specifications subject to change without notice. APPLICATION CONSIDERATIONS The proper selection and application of power generation products and components, including the related area of product safety, is the responsibility of the customer. Operating and performance requirements and potential associated issues will vary appreciably depending upon the use and application of such products and components. The scope of the technical and application information included in this publication is necessarily limited. Unusual operating environments and conditions, and other factors can materially affect the application and operating results of the products and components and the customer should carefully review its requirements. Any technical advice or review furnished by Regal Beloit America, Inc. and its affiliates with respect to the use of products and components is given in good faith and without charge, and Regal assumes no obligation or liability for the advice given, or results obtained, all such advice and review being given and accepted at customer s risk. For a copy of our Standard Terms and Conditions of Sale, Disclaimers of Warranty, Limitation of Liability and Remedy, please contact Customer Service at 1-888-888-0110. These terms and conditions of sale, disclaimers and limitations of liability apply to any person who may buy, acquire or use a Regal Beloit America Inc. product referred to herein, including any person who buys from a licensed distributor of these branded products. Thomson Power Systems and Regal are trademarks of Regal Beloit Corporation or one of its affiliated companies. 2016, 2017 Regal Beloit Corporation, All Rights Reserved. CL056r11 17/04/24