Combo HPU Kidney Loop Motor

Similar documents
Sunwize Power Ready Express Quick Start

Contractors Guide Central Inverter System Installation

XENON POWER SUPPLY 4000 Watt Gladiator IV

Sunwize Water Pumping Kit Quick Start

This harness kit includes: Installing the Hybrid ReVolt Universal grid charger in an Insight

Installing the Switch Chassis

INSTALLATION INSTRUCTIONS

Dynamic Braking Kit for FlexPak 3000 and WebPak 3000 Digital DC Drives 1.5 HP to VAC, 3 HP to VAC without NEMA1 Enclosures

INSTALLATION INSTRUCTIONS C-VS-2000-DUR-1 20 VEHICLE SPECIFIC CONSOLE for 2018 Dodge Durango with Standard Shifter

SCM-Power Distribution PLUS system Installation and User Instructions:

INSTALLATION INSTRUCTIONS

SED2-BT300-XX-C09 Migration Kits. Product Numbers

5000 SERIES POWER SUPPLY/CHARGERS INSTALLATION GUIDE

Air Conditioner for M915 A0/A1 Truck

INSTALLATION INSTRUCTIONS

Double Pole Circuit Breaker Kit for Non-Regenerative MinPak Plus DC Drives

Hybrid XT Retrofit GE 1.5 SLE Turbines

For additional information, please refer to the Installation/Operation Manual

INSTALLATION INSTRUCTIONS

Table 3. Pumping Range. 6 in cm. 8 in cm. 16 in cm. 6 in cm. 14 in cm. 18 in cm.

4RE Tahoe Bracket Installation Manual

Installing and Removing Power Supplies

CANOPY WIRING PATCH KIT INSTALLATION INSTRUCTIONS Holden Colorado RG

BOXER KING 5600/5600R TRUCK TYRE CHANGER

05 09 Mustang Squirter Nozzle Relocation Kit CDC #112050

Installation Instructions for Key Switch SNOWRATOR

Condenser Fan Pak Installation and Wiring Guide

This harness kit includes: Civic harness (2003 to 2005) Installing the Hybrid ReVolt Universal grid charger in a First Gen Civic ( )

SX-16 Nightsun Searchlight Safety and Service Bulletin # SL

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Please Read The Entire Bulletin Before Proceeding

INSTALLATION INSTRUCTIONS

Milwaukee's Electric Actuator Installation, Operation & Maintenance Manual

Komfot (EC) SB v5(6) INSTALLATION GUIDE HEAT RECOVERY AND HEAT AND HUMIDITY RECOVERY AIR HANDLING UNIT

Accessory Kit Estimated Fitting Time: 120 Minutes

SMIDLEY MINI-SCALE RETROFIT INSTRUCTIONS

INSTALLATION INSTRUCTIONS

TABLE OF CONTENTS INTRODUCTION 3. INSTALLATION PROCEDURES Air Conditioner Location 4. A/C Ducting Installation 5

05 09 Mustang Squirter Nozzle Relocation Kit CDC #112050

ENGINE DEVELOPMENT INC.

INSTALLATION INSTRUCTIONS

B3 Bypass Step by Step Installation Guide

INSTALLATION INSTRUCTIONS FUEL SURGE TANK KIT

INSTALLATION INSTRUCTIONS

SUT-450-I ASSEMBLY REQUIREMENTS

Mitsubishi Turbine: Hybrid XT Control Sensor Retrofit

Instructions on installing the R/R to the front battery cover.

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

YZ-PSSB10 Yamaha YXZ 1000 R Behind Seat 10 Subwoofer Enclosure

ON DEMAND INSTALLATION GUIDE

Installation and Service Manual

Kit. Hydraulic Kit Installation Guide REV A. Item Component Part Number Qty

INSTALLATION INSTRUCTIONS

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

INSTALLATION INSTRUCTIONS

Electric Actuator Installation, Operation & Maintenance Manual

INSTALLATION MANUAL. Power-Pole Blade Edition Shallow Water Anchor. Installation Instructions

Installing Power Components

Installation Guide. Enhanced Easy-Stop Trailer ABS 2S/2M Standard with PLC Installation Instructions TP Revised 1 Technical Bulletin

ELECTRIC START KIT KIT P/N

INSTALLATION INSTRUCTIONS DRAWERS #240

Installation Instructions

TECHNICAL PROPOSAL For Quotation #7254

INSTALLATION INSTRUCTIONS

Mobile Video Installation Guide

Technical Data Sheet

INSTALLATION INSTRUCTIONS

Fitting Instructions

JB104SS Junction Box

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

Power Operated Retrofit Kit for Manual Door 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

Field Replacement of Fluorescent Power Supply in L-858 Signature Series Sign

960 PS Series Hydraulic Power Pumps

Infinity 1U 19 Converter Shelf Models: J L224-48V to +24V, L V to -48V

HC-11 Programmer (optional)

C44090 HP325 PACBRAKE COMPRESSOR CONVERSION

Mounting an EX 8200 series Switch on a Rack or Cabinet Without Using a Mechanical Lift

With its new PACE -B Series Rig, Nabors continues to advance industry standards in drilling technology and innovation.

At-FST Series I N S TA L L AT I O N A N D O P E R AT I N G I N S T R U C T I O N S W W W. A I G I S M E C H. C O M

TABLE OF CONTENTS INTRODUCTION.. 3. A/C Ducting Installation. Power Kit Installation (Batteries)...5 OPERATION MANUAL 7-8 TOOLS LIST..

Mid-Power Remote Unit (MRU) Outdoor Enclosure MIMO Assembly Quick Installation Sheet

Selection HP V Class V Class Input: 3 Phase Output Voltage: 3 Phase V at 60Hz Voltage Toleran

Ram 1500 Crew Cab A Ram 2500/3500 Crew Cab A

Procharger Stage II Intercooled Supercharger System (11-14 GT)

ILQ TROUBLESHOOTING GUIDE

SWX-100-INT-PCR Internal Isolation Switch

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Installation Instructions

Guide to Installing Y o u r H a r m a r S t a i r L i f t

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Item. Table 1. Circuit Breaker Replacement Kit 1. Item Part No. Description QTY. Remarks No. Includes. Items Items EE55781 WORK SAFELY!

INSTALLATION INSTRUCTIONS

Solar PV General Introduction Guide for Electricians

Fitting Instructions

INSTALLATION & OWNER S MANUAL

I-Sheet Number Rev.B 3-1/2 OVAL BULL BAR DODGE RAM 1500

Installation Instructions: Side Delivery Units BDS-2555

Instructions for assembly, operation and maintenance of motor operated drives VM20/30-K, and hand operated drives DK

RMK HANDLEBAR KIT P/N ; ; APPLICATION BEFORE YOU BEGIN KIT CONTENTS. Verify accessory fitment at Polaris.com.

INSTALLATION INSTRUCTIONS

Transcription:

Serial #: See below Product Bulletin # DC-002 Combo HPU Kidney Loop Motor Serial numbers DC1041-DC1050, DC1052, DC1053, DC1055-DC1057, DC1062, DC1064, DC1068, DC1070, DC1072 Background The Combo HPU Part Number AY17915 and AY17915-1 utilize a capacitive 2HP, 208-230V/1ph/60Hz motor in the kidney loop to drive the circulating pump for oil cooling and reservoir filling. When supplied with grid power, the motor operates normally during factory acceptance testing. However, when supplied with generator power, the generator output voltage often falls below the minimum supply voltage, causing the amperage draw to increase to the point that the circuit breaker is tripped before the motor can generate enough starting torque. Recommendation Replace the single phase 2HP motor with a 2HP/460V/3ph/60Hz motor. Install a Variable Frequency Drive (VFD) kit to convert single phase supply power from the lighting panel to three phase power supply. Parts Required Canrig Part Number AY18779 - VFD Installation kit with three phase 2HP motor. Contact RigLine 24/7 Support to order the kit. Reference Schematics PACE_COMBO HPU_WRENCH_VFD Tools Required Wire Cutters Wire Strippers Ratchet and Sockets Allen Wrench Set Flat Head Screwdriver Phillips Screwdriver 3 ft Black 18 ga. Wire

Determine Existing Configuration Determine motor type currently installed and check power supply from lighting panel. 1. Lock out and tag out all power to the Driller's Cabin Lighting Panel and Combo HPU. 2. Remove the cover on the side of the HPU and check if the motor is single phase (See Figure 1) or three phase (See Figure 2). Figure 1: Green- Weg # 00218ES1E145TC, single phase motor. Figure 2: Blue- Weg # 00218ET3E145TC, three phase motor. 2

3. Check the Lighting Panel in the Driller s Cabin for a two pole (See Figure 3) or three pole breaker (See Figure 4). Figure 3: Two pole breaker Figure 4: Three pole breaker If the HPU has a three phase motor installed and the Driller's Cabin has a three pole breaker, then no further action is required. If the motor is single phase and a two pole breaker is installed, follow the installation instructions below to install the three phase motor and VFD. Install the Three Phase Motor and VFD This procedure should only be performed by a trained technician as it requires programming of the VFD and involves voltages up to 230 VAC. 1. Lock out and tag out all power to the Driller's Cabin Lighting Panel and Combo HPU if not already performed prior to status check above. 3

2. Remove the four bolts holding the coupler to the pump (Figure 5). Bolts Figure 5: Coupler bolts (One not pictured) 3. Remove cable 257/PUMP and the four bolts securing the motor to the HPU (See Figure 6). Cable Bolt Figure 6: Cable and securing bolts for the HPU motor shown. (Three additional bolts not pictured) 4

4. Note the position of the removed motor coupling and fix it to the new motor (See Figure 7). Figure 7: Coupling on the removed motor 5. Mate the new motor with the pump coupler using the four bolts removed previously. Then mount the motor back to the chassis. 6. Remove the remaining cover and situate the VFD enclosure with the cable glands away from the temperature switch to get a reference on the mounting holes (See Figure 8). Opposite cable gland side Temperature switch Remaining cover Figure 8: Opposite side cover and temperature switch 5

7. Mark the mounting holes at 9.25 inches back and 1.5 and 2.5 inches up on each side of the fork lift arm pocket (See Figure 9). Verify marks are aligned with holes in angle bracket and drill 7/16" holes at each mark. Install the angle brackets and enclosure using the 3/8" fasteners included with the kit. 9.5 Fork Lift Arm Pocket 2.5 1.5 VFD Enclosure Right Mounting Bracket Figure 9: Installing the VFD enclosure support bracket 6

8. Using an allen wrench, remove the valve handle and key (See Figure 10). Rotate key and replace valve handle to close in the opposite direction for proper clearance. Valve Figure 10: Valve 7

9. Route cable A to the junction box in place of cable 257/Pump. Connect the black wire to TB3.9 and the red cable to TB3.10 (See Figure 11). TB3.9 & TB3.10 Figure 11: Terminal Block 3, 9 and 10 10. Connect the white wire to TB2.9 (See Figure 12). Ground the green wire to a free earth ground terminal. Jumper TB18.2 to an earth ground terminal. TB2.9 Figure 12: Connection point 9 in Terminal Block 2 8

11. Route cable B to the newly installed motor and wire it for 208-230 VAC three phase power supply (See Figure 13). U V W GND BLK WHT RED GRN T1 T2 T3 GND MTR3 M KIDNEY LOOP 2 HP 230v/3Ø/60Hz 65.8 FLA 1740 RPM Figure 13: Newly installed three phase motor 12. In the Driller's Cabin Wrench PLC cabinet, disconnect M3, OL3, and CR1 (See Figure 14). OL3 CR1 M3 Figure 14: Driller s Cabin Wrench PLC cabinet 9

13. Connect cable 434 and cable 434A with a 1 to 1 configuration using TB8 (See Figure 15). Figure 15: Terminal Block 8 14. Connect TB6.18 to 0 VDC using a black 18 ga. jumper wire (See Figure 16). Figure 16: Terminal Block 6 10

15. Turn the Lighting Panel breaker power back ON and program the BOP on the VFD using the parameters listed below (See Figure 17). Figure 17: VFD parameters 16. Press and hold the auto-fill button to listen for motor start up. Refer to schematics if not functioning properly. 11

17. Turn the Wrench Driller's Console ON and go to the PLC test screen (See Figure 18). Press the Cooler Fan button and check for proper operation. Cooler Fan Button Figure 18: PLC test screen 12