Standard Drives A & D SD Application Note

Similar documents
Código de rotor bloqueado Rotor bloqueado, Letra de código. Rotor bloqueado, Letra de código

Inverter control of low speed Linear Induction Motors

Technical Explanation for Inverters

TRIPS AND FAULT FINDING

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

Permanent Magnet Synchronous Motor. High Efficiency Industrial Motors

TOSVERT VF-S11. V/F control functions

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

GHD Global Help Desk. HOISTING commissioning with ATV71 03/2010

Overvoltage Suppression F7 Drive Software Technical Manual

VFD E Series. Features

SINAMICS SM150. 4/2 Overview. 4/2 Benefits. 4/2 Design. 4/6 Function. 4/8 Selection and ordering data. 4/8 Options

Planning and Commissioning Guideline for NORD IE4 Synchronous Motors with NORD Frequency Inverters

SINAMICS GM150 IGCT version

DYNEO Synchronous motors with permanent magnets-drive Commissioning

Scheme - I. Sample Question Paper

VLT AutomationDrive for marine winch applications

Application Note CTAN #234

Piktronik d. o. o. Cesta k Tamu 17 SI 2000 Maribor, Slovenia Fax:

General Purpose Permanent Magnet Motor Drive without Speed and Position Sensor

Unit Protection System for Pumped-Storage Power Stations

Drive Fundamentals. Motor Control Bootcamp May 15-18, Copyright 2015 Rockwell Automation, Inc. All Rights Reserved. PUBLIC CO900H

Motor parameters setting. Motor Control Parameters. These motor parameters below are needed to set:

CHAPTER THREE DC MOTOR OVERVIEW AND MATHEMATICAL MODEL

Whitepaper Dunkermotoren GmbH

INTRODUCTION. I.1 - Historical review.

R13 SET - 1. b) Describe different braking methods employed for electrical motors. [8M]

Low Speed Control Enhancement for 3-phase AC Induction Machine by Using Voltage/ Frequency Technique

Yaskawa AC Drive L1000A Supplement to the L1000A Technical Manual No. SIEP C , SIEP C , and SIEP C

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop]

Practical Variable Speed Drives and Power Electronics

Principles of iers (intelligent

Modern Motor Control Applications and Trends Tomas Krecek, Ondrej Picha, Steffen Moehrer. Public Information

Power Factor Improvement

Closed-loop torque control and load distribution

TUTORIAL Motor Control Design Suite

Step Motor. Mechatronics Device Report Yisheng Zhang 04/02/03. What Is A Step Motor?

Automatic control. of the doors. 99 VF Evolution

Servo and Proportional Valves

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

3rd International Conference on Material, Mechanical and Manufacturing Engineering (IC3ME 2015)

Synchronous Motor Drives

Artificial-Intelligence-Based Electrical Machines and Drives

DEPARTMENT OF EI ELECTRICAL MACHINE ASSIGNMENT 1

Product Manual. 42BYGH40(M)-160-4A NEMA 17 Bipolar 5.18:1. Planetary Gearbox Stepper

Tension Control Inverter

Introduction. Introduction. Switched Reluctance Motors. Introduction

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

List of Tables: Page # Table 1: Emerson Commander SK VFD parameter settings 2. Table 2: Allen Bradly Power Flex 4M VFD parameter settings 3

Designing Drive Systems for Low Web Speeds

QUESTION BANK SPECIAL ELECTRICAL MACHINES

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

High starting performance synchronous motor

MAGPOWR Spyder-Plus-S1 Tension Control

1.1 Block Diagram of Drive Components of Electric Drive & their functions. Power Processor / Modulator. Control. Unit

SPEED AND TORQUE CONTROL OF AN INDUCTION MOTOR WITH ANN BASED DTC

Lecture 19. Magnetic Bearings

ELECTRIC MACHINES EUROLAB 0.3 kw

The MICROMASTER has four modes of operation:

Unit III-Three Phase Induction Motor:

ELECTRICAL POWER SYSTEMS 2016 PROJECTS

CRANE FUNCTION MANUAL. FR-A (0.4K) to 04750(90K)-CRN FR-A (0.4K) to 06830(280K)-CRN FR-A (315K) to 12120(500K)-CRN

ELECTRIC MACHINES EUROLAB 0.3 kw

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1001 SPECIAL ELECTRICAL MACHINES

Speed Control of Induction Motor using FOC Method

H02P /00 Arrangements for stopping or slowing electric

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

Application for Drive Technology

B.E-EEE(Marine) Batch 7. Subject Code EE1704 Subject Name Special Electrical Machines

Guidelines for connection of generators:

EXPERIMENTAL VERIFICATION OF INDUCED VOLTAGE SELF- EXCITATION OF A SWITCHED RELUCTANCE GENERATOR

INTELLIGENT FLANGE STRÖTER. Magnetic pulse generator

Quick Start Guide of CV50- ControlVIT Series

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

THREE PHASE RECHARGING SYSTEM DIAGNOSIS

InstaSPIN-FOC Training

For motors controlled

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

HIDRA CRONO Controller VVVF Control Techniques Unidrive SP (Asynchronous motors)

Unidrive M700 Class leading performance with onboard real-time Ethernet

MCW Application Notes 24 th August 2017

Qingdao Zener Electric Co., Ltd

Statcom Operation for Wind Power Generator with Improved Transient Stability

Tuning the System. I. Introduction to Tuning II. Understanding System Response III. Control Scheme Theory IV. BCU Settings and Parameter Ranges

Design, Engineering, and Manufacturing of Motors for Electric Vehicle Applications

FLL Workshop 1 Beginning FLL Programming. Patrick R. Michaud University of Texas at Dallas September 8, 2016

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

FL-100-R (109) Operations and Installation Manual

EXPERIMENT 13 QUALITATIVE STUDY OF INDUCED EMF

V1000, A1000, E7, F7, G7,

Control System Instrumentation

Single Phase Induction Motors

R07 SET - 1

Control System Instrumentation

INDUCED ELECTROMOTIVE FORCE (1)

30 top tips to tackle HVAC challenges No.03 - Permanent magnet motors

PLUGGING BRAKING FOR ELECTRIC VEHICLES POWERED BY DC MOTOR

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Automatic Energy Saving Control

Dev Bhoomi Institute Of Technology LABORATORY Department of Electrical And Electronics Engg. Electro-mechanical Energy Conversion II

Transcription:

SENSORLESS VECTOR CONTROL (SVC) Version A, 30.07.99 More detail of Vector Control principles are explained in DA64 Section 2. Some examples of SVC are given in Sections 4.2, 4.3 and 4.4. The MICROMASTER Vector Operating Instructions describe briefly the setting of parameters for SVC operation. DA64 Ref. Micro and MidiMaster Vector Operating Instructions E20002-K4064-A101-A2-7600 (English) 6SE3286-4AB66 (English) These documents are available from Siemens sales offices or from http://www.con.siemens.co.uk Sensorless Vector Control Operation An inverter controls the speed of an AC motor by varying the applied frequency. The speed of the motor depends mainly on the applied frequency, but to some extent on the load as well. It is also necessary to control the voltage applied to the motor in order to maintain the correct flux in the motor. For optimum motor performance, the exact value of flux should be controlled with respect to the rotor position as well as the load current. This requires that the stator current be controlled in magnitude and phase the Vector quantity. To control the phase with reference to the rotor it is necessary to know the position of the rotor. Hence for full Vector control an encoder must be used as a transducer to tell the inverter the rotor position. However many applications do not need and cannot justify the additional expense of a position encoder. In SVC, the inverter itself simulates the attributes of the encoder by means of a software algorithm which accurately calculates the rotor position and speed by mathematically modelling the properties of the motor. To do this the inverter must: monitor the output and current very accurately calculate or measure motor parameters (rotor, stator resistance leakage inductance etc.) accurately model the motor thermal characteristics adapt motor parameters with varying motor operating conditions have the ability to perform these mathematical calculations very rapidly When to use SVC It is used to provide Good speed control with inherent slip compensation High torque at low speed without excessive boost Higher dynamic performance - better response to step loads Stable operation with large motors. Large lightly loaded motors can sometimes be unstable during inverter operation Better performance at current limit with improved slip control Created by Martin Brown, Version A, 30.07.99 Page 1 of 6

It cannot be used for Synchronous or reluctance motors Multi-motor drives, group drives (several motors connected in parallel at the drive converter output Motors with power ratings less than half of the inverter rating Motors with power ratings greater than the inverter. (For the above cases a V/f characteristic must be parameterised) Notes on using SVC The motor speed is controlled in this mode and this is shown in the display. That is, the frequency shown in the display is the calculated rotor frequency, not the inverter output frequency, which will usually be higher than the rotor speed due to the motor slip. In other modes output frequency is shown. If the inverter is unable to correctly calculate the rotor position SVC is lost and a fault will be indicated. Setting up Sensorless Vector Operation is described in the operating manual in section 5.3.3. This description is included below for completeness 5.3.3 Operation (P077 = 3). When SVC operating mode is selected (P077=3), the inverter uses an internal mathematical model of the motor, together with accurate current sensing, to calculate the position and speed of the rotor. It is therefore able to optimise the applied voltage and frequency to the motor to give improved performance. Output to Motor Setpoint Input Error P, I, Processor (P386, P387) Internal Motor Model Motor Model, Position and Torque feedback Although there is no position or speed feedback from the motor, the control system is a closed loop system because it compares the internal motor model performance with the desired performance. The system must therefore be carefully set up and stabilised for best performance. Created by Martin Brown, Version A, 30.07.99 Page 2 of 6

Setting up SVC Operation 1. Set the correct Motor parameter settings in Parameters P080 to P085. 2. Select Sensorless Vector Operating mode P077 = 3 3. Ensure that the motor is cold and apply a run command. The display will show CAL to indicate that it is measuring the motor stator resistance. After a few seconds the motor will run. Calibration only occurs the first time that a run command is given following P077 being set to 3. It can be forced by changing P077 from SVC operation and back again, or by selecting P088 =1 (Stator Resistance Calibration. Interrupting the calibration process by disconnecting the power or removing the run command may give erroneous results and calibration should be repeated. If motor parameters are changed recalibration is also recommended. 4. Like any control system, SVC must be stabilised by setting the gain (P386) and Integral (P387) terms. Actual values and setting up is determined by testing, but the following procedure is suggested: Whilst the inverter is operating under typical conditions, increase the value of P386, the loop gain, until the first signs of speed instability occur. The setting should then be reduced slightly (approx. 10%) until stability is restored. As a guide, the optimum setting required will be proportional to the load inertia. For example: P386 = Load inertia motor shaft inertia motor shaft inertia P387, the integral term, may now be adjusted. Again, whilst operating the inverter under typical conditions, increment this parameter until the first signs of speed instability occur. The setting should then be reduced slightly (approx. 30%) until stability is restored. If fault code F016 occurs, this indicates that SVC is unstable and further adjustment or recalibration is needed. F001, DC link overvoltage can also be caused by instability in SVC operating mode. Created by Martin Brown, Version A, 30.07.99 Page 3 of 6

Adjustment of P386 and P387. Additional Notes. P386 Sensorless vector speed control loop gain -proportional term The default setting is 1.0. The range is 0.0 to 20.0. To optimise the dynamic performance of the vector control this parameter should be incremented whilst the inverter is operating under typical conditions until the first signs of instability occur. The setting should then be reduced slightly (approx. 10%). The optimum setting of P386 will be proportional to the load inertia i.e. low values of P386 correspond to low inertia loads and high values of P386 correspond to high inertia loads. If this setting is too high or too low, rapid load changes may result in DC link over voltage trips (F001) or loss of orientation (F016). The effects of different values of P386 are shown on the next page. Note, If practical a speed feedback indicator should be used with a scope and the setting adjusted using the oscillograms illustrated on the next page. As a guide, the theoretical value of P386 is given by P386 = (Load Inertia motor shaft inertia)/ motor shaft inertia P387 Sensorless vector speed control loop gain integral term P386 must be optimised before adjusting P387. Whilst operating the inverter under typical conditions, increment this parameter until the first signs of instability occur. The setting should then be reduced slightly (approx 30%) until stability is restored. The effects of different values of P387 are shown on the next page. Note if practical, a speed feedback indicator and scope should be used as for P386.and the setting adjusted using the oscillograms illustrated on the next page. Created by Martin Brown, Version A, 30.07.99 Page 4 of 6

Effects of P386 and P387 100% Torque Step P386 Optimised (P387 = Default) P386Too High (P387 = Default) P386 Too Low (P387 = Default) P386 Optimised P387 Optimised P386 Optimised P387 Too high P356 Optimised P387 Low Value Time Created by Martin Brown, Version A, 30.07.99 Page 5 of 6

System instability will cause high motor currents, regeneration as motor speed changes rapidly, or loss of sensorless vector control. These will result in fault codes F001, F002 or F016 respectively. Sensorless Vector control does not operate below 2.5Hz (5Hz with 2.5Hz hysterisis). In this range the inverter controls the motor torque by maintaining a constant current in the motor. The block diagram of the Sensorless Vector control algorithm is shown below in more detail. EMF computer for pre-control Converter " n* Ramp Generator dn*/dt - n-controller I Start * M Acc. I#* % M* M* IW* I W* I# - Controller I W-controller Coord transformer U* U d- Corr -ection U St $ Gating unit f < f s f f > f s Effective at f > f s Load Control f Iw ist Iµ ist Motor Model with vector transformation U I f Slip n calculated M The control system is highly complex, and utilises software and control algorithms developed for other, larger Siemens drives together with an extremely fast floating point calculator. Created by Martin Brown, Version A, 30.07.99 Page 6 of 6