TESTLINK COMPLIANCE WESTUSA. Remote Actuation Cable Set. Instruction Manual

Similar documents
HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

GF-30AC. Ground Circuit Tester COMPLIANCE WESTUSA. Instruction Manual

HT-25kVdc Dielectric Withstand Tester Volts DC Output

GFM-40ac COMPLIANCE WESTUSA. Ground Circuit Tester. Instruction Manual

HT Dielectric Withstand Tester Volts AC Output Volts DC Output COMPLIANCE WESTUSA. Instruction Manual

HI-POT/CONTINUITY TESTER Model PLEP01

Dielectric Withstand Tester

HT-2000 Dielectric Withstand Tester Volts AC Output

MegaPulse 1.2x50-8 PV

Fast Charge Option (IEC 335) MegaPulse Surge Testers

GFM-200A. Instruction Manual

MegaPulse. Antenna Surge PF 65

MegaPulse. IMPULSE TESTER Implantable Test 1. Instruction Manual

Ensuring the Safety Of Medical Electronics

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

"Engineered to Ride, Built to Last "

"Engineered to Ride, Built to Last "

Installing Power Components

ACL 780/781 Economy Combo Tester

Models: EP EP EP EP EP EP USER MANUAL ENGLISH

How to bias: V3M, V3MC Rev A 9/23/2011

USER MANUAL. Insulation Tester + DMM. Model MG320

Powerware Vdc Extended Battery Cabinet User s Guide.

Component Test Fixture

Switching DC Power Supply

TECH XP125 INSTALLATION AND OPERATION MANUAL.

WIRELESS TRI-JACK WIRELESS REMOTE KIT COMPONENTS LITERATURE NUMBER REV. C WARNING EXPLOSION WARNING PERSONAL INJURY & PROPERTY DAMAGE

Model (Circuit Tester) Model (GFCI Tester)

"Engineered to Ride, Built to Last "

100 Watt Power Amp 50 Watts x 50 Watts Single Rack Space

HYAMP III. Quick Start Guide

PRODUCT INFORMATION BULLETIN #3365 DIGITAL MOTOR CONTROL PLATTER SYSTEMS For Serial Number and After

VARIABLE RESISTANCE REFERENCE PAR-809C. User Manual

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

"Engineered to Ride, Built to Last "

TECH XP250 INSTALLATION AND OPERATION MANUAL. Manufacturer of UL Listed Products.

How to bias: MTS3200, MTS3212 Rev A 8/1/2008 carvinservice.com

TESTER ISOLATION MODULE LIGHT SYSTEM. Operating Instructions. CAUTION Read this document before testing any snowplows.

TECH XP600/1100 INSTALLATION AND OPERATION MANUAL. Manufacturer of UL Listed Products.

"Engineered to Ride, Built to Last "

Engineered to Ride, Built to last

PRODUCT SPECIFICATION

TECH XP600/1100 INSTALLATION AND OPERATION MANUAL

"Engineered to Ride, Built to Last "

ITS-50R TRANSFER SWITCH OWNER S MANUAL

Battery Control Center - Diesel

ATD WATT INVERTER

P70 Series MICRO-SET TM Pressure Controls for Refrigeration and Air Conditioning, 4-Wire, 2-Circuit Contact Block

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

ATD WATT INVERTER

Does Your Electrical Safety Testing Routine Need a Boost? Exploring the Benefits of the Line Leakage and Functional Run Tests

!" # 0*.!0&!&1* &23# 0

G600 Series Replacement Intermittent Pilot Ignition Controls

OPERATION AND SERVICE MANUAL. Model 2512, 2515

KIT CONTENTS

Control Replacement # Page 1 REPLACEMENT OF OBSOLETE SEMI- AUTO CONTROLS WITH KIT #

Installing and Removing Power Supplies

Rack Mount Power Supplies

"Engineered to Ride, Built to Last "

BRAVO Inverter/Battery Charger. Table of Contents

24V 3A EN54 Ancillary Power Supply

SimplePAT. Battery Powered Portable Appliance Tester. User Manual Issue 1.0

Uninterruptible Power System

XP600/1100/2000 INSTALLATION AND OPERATION MANUAL

"Engineered to Ride, Built to Last "

INTELLIVALVE 2-WAY, 3-WAY VALVE ACTUATOR

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION. Batteries Battery connections

SP6. Automatic Battery Charger. Model

AUTO CHARGE LPC SERIES

Company Switch Installation Instructions and User Manual

Switch rated plugs and receptacles

KenkoAir_Purifier manual ENG-FR_FDA 10/12_Air Filter manual 8/15/13 10:44 AM Page 1 OPERATING MANUAL

Model Fixed Rack-Mount Kit

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

Avoid nasty shocks Electrical safety for industry

"Engineered to Ride, Built to Last "

"Engineered to Ride, Built to Last "

Uninterruptible Power System

WIRELESS CAMPER JACK LITERATURE NUMBER REV. C CCD WARNING PERSONAL INJURY & PROPERTY DAMAGE WARNING EXPLOSION. Effective NOV 2018

Triple Output High Resolution Power Supply. User Manual

Raritan PX. Power Cord Installation Guide. Safety Guidelines. Safety Instructions

Troubleshooting 3Z8 038 Rev B

User s Guide. MCM Backpack. Model BP-1. Part # 12715

MPA Chassis for Multi-Probe Magnetic Transducers

50407 / DUAL INDEPENDENT FOOTWEAR AND WRIST STRAP TESTER

"Engineered to Ride, Built to Last "

Thank you for purchasing the CHP Assembly Tool. In order to ensure maximum

"Engineered to Ride, Built to Last "

Models: SP3, SPSS3 Automatic Battery Charger

!" # )("*"+,$' 0*.!0&!&1* &23# 0 &*&.444#3# 0

ALLEN GROUP INT L INC

Y99AB-4 BASO Test Kit

BC-1230P/ 1240P/ 1260P Multi-Stage Battery Chargers User Manual

Q35 Series Automatic Vent Damper System

"Engineered to Ride, Built to Last "

Model: SE-4020-CA Automatic Battery Charger

MODEL 2001 HERMETI-CHECK OPERATING INSTRUCTIONS

"Engineered to Ride, Built to Last "

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Transcription:

TESTLINK Remote Actuation Cable Set Instruction Manual COMPLIANCE WESTUSA

Dear Customer: Congratulations! Compliance West USA is proud to present you with your Interconnect Cables. They allow our groundbreaking Hipot and High Current Ground Testers to work together, representing the culmination of years of advanced design. Before using the cable set, we suggest that you take a few moments to review this manual. Thank you for your trust and confidence. Rev. 6.0, July 2011

Table of Contents Introduction...1 Operation...2 Contents of the Set:...2 Standalone Operation of the HT and GF Testers...2 Interconnecting the HT and GF Testers...2 Figure 1. Testlink Connections...3 Initial Checkout Procedure...4 Testing Products with the Interconnected Testers...5 Technical Assistance...6

Section 1 Introduction This manual contains complete operating instructions for the Compliance West USA Model TESTLINK Interconnect Cable Set. The Testlink connects the two testers together to allow a simpler test setup. Now both the high current ground continuity test and the dielectric withstand test can be done by pressing one button. 1

Section 2 Operation This section describes how to connect the TESTLINK option. Please read the Section over so the TESTLINK can be installed correctly. Contents of the Set: The TESTLINK Cable Set should include the following: A red/black 10 AWG Test Lead (NEMA 5-15 plug to banana plug ends) A DB-9 to DB-9 Interconnect cable. This Instruction Manual Standalone Operation of the HT and GF Testers The GF and HT Testers can be used alone if desired. Disconnect all the Testlink cables and connect the DB-9 dongle to the DB-9 jack on the rear panel of the dielectric withstand tester. The dongle is connected to the back of the HT tester. The ground continuity tester will operate without modification. Refer to the Tester Manuals for more information about conducting tests. Interconnecting the HT and GF Testers This section will explain how to connect the Testers to allow one-touch testing for both a high current ground test and hipot test. The equipment being tested will be connected to the HT Hipot Tester, and the Test button on the HT will control both tests. The settings can be adjust before interconnecting the testers or after while running the test. 1. Arrange the HT Hipot Tester and GF Ground continuity Tester with the HT on top of the GF. 2. Locate the red/black 10 AWG test lead cable shipped with the TESTLINK. Plug the NEMA 5-15 plug into the "Device" plug on the front of the GF tester. 3. Connect the banana jacks of the red/black 10 AWG test lead cable to the appropriate jacks on the rear panel of the HT Tester. NOTE: they are labeled Red and Black. 4. Connect the gray DB-9/DB-9 Cable between the DB-9 Plugs on the rear panels of the testers. 5. Turn the Ground Check switch on the rear of the HT to the "ON" position. 6. See Figure 1. 2

Figure 1. Testlink Connections 3

Initial Checkout Procedure 1.- Unplug all cables from the front panel of the HT 2.- Turn ON HT Tester and set the desired settings. Refer to HT-XXXP manual for more information about the settings. 3.- Turn OFF HT Tester. 4.- Unplug all cables from the front panel of the GF-30AC 5.- Turn ON GF-30AC and set the desired settings. Refer to GF-30AC manual for more information about the settings. 6.- Turn OFF HT Tester. 7.- Interconnect the HT and GF-30AC testers. See Figure 1. 8.- Turn ON HT and GF-30AC testers. 9.- Switch the Ground Check to the OFF position on the rear panel of HT Tester. 10.- Press the reset button on the HT Tester. 11.- Press the TEST button on the HT tester to run the test on both testers. Test should be as follows: 11.1.- GF-30AC must perform the Ground Continuity Test 11.2.- After the GF-30AC finish the test, the HT tester will run the HIPOT and LEAKAGE test, 11.3.- Make sure both tests pass. Refer to HT-XXXP and GF-30AC manual for more information about pass and fail test. 11.4.- If necessary adjust the settings of the HT Tester. 4

Testing Products with the Interconnected Testers This section explains how to connect the Testers to a piece of equipment being tested. Note: The light gauge return lead packaged with the HT Dielectric Withstand (Hipot) Tester is not used when combination testing is being conducted. Please remove this cable from the HT Tester and put it away. 1. Locate the 10 AWG test return lead that was packaged with the GF-30AC Tester. Connect it to the "Return" jack located on the front panel of the HT Tester. The other end of the 10 AWG test lead will be connected to the chassis of the equipment being tested. Because of the high current flowing, do not use the 18 AWG return lead provided with the HT Tester when the units are interconnected. 2. If you are testing equipment using an appliance inlet and a detachable AC line cord, locate the 14 AWG Line Cord that was packaged with the GF-30AC Tester. Connect it to the "Device" plug on the front panel of the HT Tester. The other end of the 14 AWG Line Cord will be connected to the equipment under test. 3. If you are testing equipment using a permanently attached power cord, special calibration procedure must be conducted first. Please see the Manual included with the GF Tester, section "Adjusting the Pass/Fail Point for products with non-removable power cords" for instructions. Note: Two-wire products not equipped with a grounded power supply cord cannot be tested when the units are interconnected. 4. Connect a product to be tested to the HT Series tester. a. Connect the clip of the 10 AWG Lead presently inserted into the "Return" jack on the front panel of the HT Tester to an exposed metal part of the chassis of the equipment being tested. b. For equipment having a detachable power cord: Connect the 14 AWG Line Cord presently inserted into the "Device" receptacle on the front panel of the HT Tester to the appliance inlet of the equipment being tested. c. For equipment with permanently attached power cords: Plug the power cord of the unit under test into the "Device" receptacle of the HT Tester. (Caution: Please be sure you have followed the instructions in Item 3 above before testing.) 5. Make sure both testers are connected to power and switched on. 6. The Reset Button on the HT Tester should be lit. Press the Reset Button. The Reset button will extinguish and the Test button will light. Push the Test button. 7. The high current ground test will be run first. The Red or Green Light on the GF Tester will indicate whether the unit under test passed this phase. a. If the unit FAILS the high current test, the HT will indicate GROUND OPEN and an audible buzzer will sound. Further testing will be terminated. b. If the unit PASSES the high current test, the HT will indicate GROUND OK and initiate the dielectric test. All subsequent results will be indicated by the HT unit. 5

Section 3 Technical Assistance For Technical Assistance Phone: (800) 748-6224 Technical Assistance is available from Compliance West USA between the hours of 8:30 AM and 4:30 PM Pacific Time. Compliance West USA 2120 Jimmy Durante Blvd., Suite 118 Del Mar, CA 92014 Phone: (858) 481-6454 FAX: (858) 481-8527 6