Flaretek Tube Fitting Heated Flare and Assembly Procedures

Similar documents
Flarelock II Tube Fitting

Ultrapure Flare Style PFA Tube Fittings

FluoroLine Ultrapure PFA Tubing

Integra Pneumatically Operated Diaphragm Valves with Position Indication Option

PrimeLock Fittings. A premium PFA fitting for high-purity and corrosive chemical applications FEATURES & BENEFITS APPLICATIONS

PrimeLock Fittings. A premium PFA fitting for high-purity and corrosive chemical applications FEATURES & BENEFITS APPLICATIONS

CR8 Manual Multi-turn Valve

Integra Pneumatically Operated Diaphragm Valves with Position Indication Option

Now available. in size. PrimeLocK Fittings. A premium PFA fitting for high-purity and corrosive chemical applications

CRITICAL MATERIALS HANDLING PRIMELOCK FITTINGS

CR4 Discrete Valve and Manifold Valve Repair or Replacement Procedure

Integra Manually Operated Distribution Valves

InVue Electronic Flowmeter, NT4400

Dymension SG Manifold Valves Using Direct Mount Manifold Technology

Integra Pneumatically Operated Valves

NT Flowmeter, Model 4401

NOWPak Canister Dispense Connector

NT ELECTRONIC FLOWMETER, MODEL 4400

Integra Pneumatically Operated Distribution Valves

Overview CHEMLOCK PFA HOUSING. Space-saving housing solution enabling hassle-free cartridge changeouts and reduced exposure to chemicals

NT PROPORTIONAL CONTROL VALVE, MODEL 6300

CRITICAL MATERIALS HANDLING FLUOROGARD RS RESIST STRIPPING FILTERS

Optimizer Point-of-use Photochemical Filters

RINSEGARD HP AND HPX. Simultaneously removes trace levels of positively charged ions and fine particles in ultrapure DI water

NT HIGH-TEMPERATURE ELECTRONIC FLOWMETER, MODEL 4401

InVue Electronic Flowmeter, Model NT4400

Integrated Flow Controller, Model NT6500

CRITICAL MATERIALS HANDLING PROCESSGARD PES CARTRIDGE AND DISPOSABLE FILTERS

WAFERGARD III NF-75O IN-LINE GAS FILTERS. Installation and use manual

Feature Advantage Benefit. Excellent chemical compatibility Better particle removal performance than polypropylene media

CRITICAL MATERIALS HANDLING TORRENTO AT SERIES FILTERS

Product overview and technical data. FlareStar Ultra pure PFA tube and weld fittings

NOWPak Bottle System. Delivering your critical materials with purity, safety, and process efficiency FEATURES & BENEFITS. Purity.

MUELLER GAS. No-Blo Valve. Changers. Reliable Connections. General Information 2-3. Plugging Unit Assembly 4-5. Removing Old Valve 5-6

SUPER TYPE PILLAR FITTING INSTRUCTION MANUAL

MAXIM 50D PUMP. Operation / Maintenance Manual

Torrento high-flux, The new standard for nondewetting PTFE filters enabling unsurpassed particle protection and yield enhancement

MUELLER GAS. Shur StopTM Unit 812 PE Line Stopping. System 8" 12" SDR Reliable Connections. General Information 2

AEGIS SGR ukit Bearing Protection Ring with Universal Mounting Brackets NEW. Product

MP and MP Diaphragm and Seal Kits for MP8000 Series Actuators

OPERATOR S CARD. Select Series H-400 Hot Melt Dispensing Guns. Safety. Description/Intended Use. Nordson Corporation P/N E

Sentinel 250 Fire Hydrant

Tool Reference Guide. Swagelok Minnesota North Dakota Appleton offers a complete line of tools and equipment to rent or purchase.

brands you trust. brands you trust Field Fabrication Manual For Plastic Lined Piping

INVUE INTEGRATED FLOW CONTROLLERS, MODELS NT6510, NT6520. User guide

HVS S 15kV Class

Please read BOTH these Installation Instructions and the General Instructions before attempting to install or operate this equipment.

Bolt Type Test Plug - Technical Specifications

Tube Plugs.

Ultrahigh-Purity Fluoropolymer Diaphragm Valves

3M Overhaul Service Kit

CIRCLE SEAL CONTROLS

CALIPER BRAKE INSTALLATION AND MAINTENANCE MANUAL

Injector. General Information CAUTION. Use only the specified injector for the engine.

M673LD3 / M673L3. Soundshield Assembly Instructions. East Coast Branch th Avenue. 15 Aegean Dr. Northwest. Suite 4 Seattle, WA 98107

HAYWARD FLOW CONTROL TBH SERIES TRUE UNION BALL VALVE INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

Installation Instructions

WARNING Acura MDX Installation Instructions BX1015. Serial Number

PROCEDURE FOR CHECKING FLUIDS (MILLS)

I & M 8000 Series. Ideal Installation Schematic. Preferred Installation. Trouble Shooting

Service Bulletin

ATP-2040 Electric Damper Actuator/Transmitter

Vibrating Mechanism Bearings

Installation Instructions

X-Tractor Series. Cutters INSTRUCTION MANUAL

GF Piping Systems. Stress Less. Pipe and Valve Support System Finally, just for plastic pipe. Patents issued and pending

VB-9323 Series. Application. Features. Applicable Literature. 2-1/2" to 6" 125 Lb. Flanged Three-Way Diverting Valves General Instructions

INSTALLATION & MAINTENANCE MODEL mm

Operation and Maintenance Instructions

"CRANE SAFETY IN CONSTRUCTION ENVIRONMENTS"

Standard Bore Flanged Ball Valves Series 7150, 730S & , 4 & 6 (DN 80, 100 & 150) Class 150 & 300

Cordless High Speed Drill

Installation Instructions

Valtek Auxiliary Handwheels and Limit Stops

Powers Controls Powermite Two-Way Flared Valves Normally Open/Normally Closed

Installation Instructions

QUICK CLEAN CHEMICAL HYDRAULIC VALVES

Technical Instructions

VERSION 1.6 PRT USER GUIDE. ZiPPERTUBiNG CO. THE. (480)

INSTALLATION GUIDE CR SERIES - DEDICATED HORIZONTAL COIL ! WARNING. 1. Safety Instruction. 2. Inspection. 3. Installation Preparation

12V Direct Drive Air Compressor 88

Hydraulic PTO Flow Device

2 Model 826 Dispensing Valve User Guide

THE RAPTOR SERIES HAWK ENTERPRISES, INC RAPTOR 2618 RAPTOR Hawk Enterprises Park Six Court Elkhart, IN 46514

1 Product Description Check of the supplied Parts Notes Intended Use Current Collector... 3

Power your day-to-day when others are power-less. Humless Sentinel User s Guide.

S&C Vista Underground Distribution Switchgear

INSTRUCTIONS FOR CONTINUED AIRWORTHINESS MAINTENANCE MANUAL SUPPLEMENT. CONCORDE TS-C2 or TS-C2A TEMPERATURE SENSOR

Installation Instructions

Installation Instructions

Parker Hydraulic Tube Bender, Model HB632

ASSEMBLY GUIDE. D-M-E Tubular Manifold & Components System

Innovative and reliable coupling designs for over twenty years. Coupling body. Coupling insert

Operation Care Service

CIRCLE SEAL CONTROLS

I-231.T2S1/CLAD. Victaulic Style 231 Non-Restrained, Flexible Expansion Coupling with Cladding on Expansion Side of Pipe WARNING IMPORTANT INFORMATION

WARNING. BX Jeep Liberty Installation Instructions. Serial Number

Defender Series. Overfill Prevention Valve. Automatic Shutoff for USTs. Installation, Operation and Maintenance Series

EST GROUP DC /96 REV 8 03/03 PAGE 1 OF 11 THROUGH-THE-TUBE PLUGGING WITH CPI / PERMA PLUGS

LT-EL138 LED Flashlight

Transcription:

ADVANCED MATERIALS HANDLING INSTRUCTION SHEET Flaretek Tube Fitting Heated Flare and Assembly Procedures Insert installation instructions for 1 4", 3 8", 1 2", 3 4" and 1" sizes SPECIFICATIONS Maximum pressure rating chart Size (X) Temperature FluoroLine 4300, 4200 PFA tubing reference PVDF nut FL(X)-1 PFA nut FL(X)-3 CPFA nut FL(X)-6 1/4 (4) 24 C (75 F) 1882 kpa (273 psig) 1551 kpa (225 psig) 1551 kpa (225 psig) 1551 kpa (225 psig) 93 C (200 F) 938 kpa (136 psig) 917 kpa (133 psig) 917 kpa (133 psig) 917 kpa (133 psig) 121 C (250 F) 586 kpa (85 psig) 689 kpa (100 psig) 689 kpa (100 psig) 689 kpa (100 psig) 150 C (300 F) 421 kpa (61 psig) 517 kpa (75 psig) 517 kpa (75 psig) 517 kpa (75 psig) 175 C (350 F) 248 kpa (36 psig) N/R 345 kpa (50 psig) 345 kpa (50 psig) 3/8 (6) 24 C (75 F) 1613 kpa (234 psig) 1551 kpa (225 psig) 1551 kpa (225 psig) 1551 kpa (225 psig) 93 C (200 F) 800 kpa (116 psig) 917 kpa (133 psig) 917 kpa (133 psig) 917 kpa (133 psig) 121 C (250 F) 503 kpa (73 psig) 689 kpa (100 psig) 689 kpa (100 psig) 689 kpa (100 psig) 150 C (300 F) 359 kpa (52 psig) 517 kpa (75 psig) 517 kpa (75 psig) 517 kpa (75 psig) 175 C (350 F) 214 kpa (31 psig) N/R 345 kpa (50 psig) 345 kpa (50 psig) 1/2 (8) 24 C (75 F) 1158 kpa (168 psig) 1310 kpa (190 psig) 1310 kpa (190 psig) 1310 kpa (190 psig) 93 C (200 F) 572 kpa (83 psig) 689 kpa (100 psig) 689 kpa (100 psig) 689 kpa (100 psig) 121 C (250 F) 359 kpa (52 psig) 517 kpa (75 psig) 517 kpa (75 psig) 517 kpa (75 psig) 150 C (300 F) 255 kpa (37 psig) 345 kpa (50 psig) 345 kpa (50 psig) 345 kpa (50 psig) 175 C (350 F) 152 kpa (22 psig) N/R 276 kpa (40 psig) 276 kpa (40 psig) 3/4 (12) 24 C (75 F) 738 kpa (107 psig) 758 kpa (110 psig) 758 kpa (110 psig) 758 kpa (110 psig) 93 C (200 F) 365 kpa (53 psig) 524 kpa (76 psig) 524 kpa (76 psig) 524 kpa (76 psig) 121 C (250 F) 228 kpa (33 psig) 241 kpa (35 psig) 241 kpa (35 psig) 241 kpa (35 psig) 150 C (300 F) 165 kpa (24 psig) 186 kpa (27 psig) 186 kpa (27 psig) 186 kpa (27 psig) 175 C (350 F) 95.5 kpa (14 psig) N/R 138 kpa (20 psig) 138 kpa (20 psig) N/R = Not recommended

SPECIFICATIONS (CONTINUED) Maximum pressure rating chart (continued) Size (X) Temperature FluoroLine 4300, 4200 PFA tubing reference PVDF nut FL(X)-1 PFA nut FL(X)-3 CPFA nut FL(X)-6 1 (16) 24 C (75 F) 531 kpa (77 psig) 517 kpa (75 psig) 517 kpa (75 psig) 517 kpa (75 psig) 93 C (200 F) 262 kpa (38 psig) 276 kpa (40 psig) 276 kpa (40 psig) 276 kpa (40 psig) 121 C (250 F) 165 kpa (24 psig) 193 kpa (28 psig) 193 kpa (28 psig) 193 kpa (28 psig) 150 C (300 F) 117 kpa (17 psig) 103 kpa (15 psig) 103 kpa (15 psig) 117 kpa (17 psig) 175 C (350 F) 68.9 kpa (10 psig) N/R 103 kpa (15 psig) 103 kpa (15 psig) N/R = Not recommended PERFORMANCE DATA Pressure vs. Temperature Pressure (psig) 250 200 150 100 50 0 50 Fluid Temperature ( C) 37.8 65.5 93.3 121.1 148.9 176.7 204.4 1 4 and 3 8 1 2 100 150 200 250 300 350 400 Fluid Temperature ( F) 1379 1034 690 345 CHEMICAL COMPATIBILITY Refer to Entegris Fluid Handling Systems catalog or web site for chemical compatibility information. FLARETEK FITTING CONNECTION The hot flaring process provides a permanent expansion (flare) of the tubing end, allowing insertion of the Flaretek fitting body. Proper tube flaring and Flaretek fitting assembly results in a secure tubing connection. 3 4 1 0 Pressure (kpa) TUBING PREPARATION 1. Cut the tubing end squarely (0.070 maximum squareness tolerance) using an Entegris tubing cutter (part number 213-14, 213-16 or 213-30). 2. Insert the cut end of the tubing through the nonthreaded end of the nut. WARNING: If you do not put the nut on the tube now you will not be able to put it on after you complete the flare. Flaretek fittings are specifically designed, tested and characterized to work together with specific Flaretek fitting components manufactured by Entegris. Customer assumes the risk of connection integrity if Flaretek fittings, body and/or nut components are attached to components manufactured by third parties. HEAT FLARING INSTRUCTIONS 1. If using an Entegris hot air gun, set the hot air gun (see Figure 1) on high. Hold the PFA tubing end flush with the heater edge and 1 2 to 3 4 above the heater and slowly rotate the tubing 360 for the approximate time specified in Table 1 or until a fine, clear line appears around the tubing. Entegris recommends these procedures for flaring standard wall Entegris PFA tubing only (0.062 wall thickness for 3 8, 1 2, 3 4 and 1 OD, 0.047 wall thickness for 1 4 ). NOTE: The tubing cools rapidly so please read and understand all instructions before flaring. 2

1/2 to 3/4 Nut Tube stop Figure 1. NOTE: It is very important to fully rotate the tubing over the heat source so all surface areas receive an equal amount of heat. Uniform heating is essential to making a good flare. If using an Entegris infrared heating tool, turn on heating tool (see Figure 2). Center 1 2 to 3 4 of the PFA tubing between the heat rings. While slowly rotating the PFA tubing back and forth between your forefinger and thumb, heat for the approximate time specified in Table 1 or until a fine, clear line appears around the tubing. Figure 3. NOTE: Flaring 1 4 tubing is the most challenging because of its small size. To get a firm grip on the small tube diameter, we recommend using the grip pad that is included in the mandrel kit (for additional grip pad, part number 213-73). 3. Firmly hold the tubing onto the mandrel for the time specified in Table 1. 4. Let the flared tubing continue to cool on the mandrel for the time specified in Table 1. NOTE: A water bath may be used to cool the tubing. If bath is used: 4a. Hold tubing on mandrel for 20 seconds after heating. 4b. Place tubing on mandrel in bath for one minute. Figure 2. NOTE: To flare 1 tubing with an Entegris infrared heating tool, a larger heat ring (part number 213-91 or 213-92) is needed. NOTE: It is very important to rotate the tubing through the heat source so all surface areas receive an equal amount of heat. Uniform heating is essential to making a good flare. 5. The flaring process is now complete and the mandrel may be removed from the tube. NOTE: An automatic bench top flaring tool is also available by Entegris (part number 213-95, 213-96, 213-95R). 2. Remove the PFA tubing from the heat source. Immediately push the flaring mandrel (see Figure 3) into the tubing until the end of the tubing reaches the tube stop. Refer to Entegris Fluid Handling Systems catalog or web site for available mandrel configurations. 3

FLARETEK FITTING ASSEMBLY INSTRUCTIONS 1. Push the flared tubing end onto the Flaretek fitting body until the end of the fitting body contacts the flare shoulder of the tube (see Figure 4). The maximum gap between the tube end and fitting shoulder should be 2.03 3.81 mm (0.08 0.15 ). Shoulder 0.08 0.15 gap Figure 4. 2. Tighten the nut onto the fitting body until handtight (see Table 1 for recommended minimum torque values). Table 1. Tubing and fitting size 1 4" 3 8" 1 2" 3 4" 1" Heating time for PFA Air gun 15 sec 25 sec 25 sec 25 sec 25 sec Infrared heater 40 sec 50 sec 50 sec 50 sec 50 sec Hold tubing on flare mandrel 20 sec 20 sec 20 sec 20 sec 20 sec Minimum cooling time on mandrel 2 min 2 min 3 min 3 min 3 min Minimum nut torque PFA fitting/pvdf nut 0.57 N m 1.58 N m (14 in lbs) 3.39 N m (30 in lbs) PFA fitting/pfa nut 0.57 N m 1.58 N m (14 in lbs) 3.39 N m (30 in lbs) PFA fitting/cpfa nut 0.57 N m 1.58 N m (14 in lbs) 3.39 N m (30 in lbs) PVDF fitting/pvdf nut 0.57 N m 2.14 N m (19 in lbs) 4.51 N m (40 in lbs) 4

RETIGHTENING After exposing the connection to operating conditions for a minimum of one hour, all fitting connections assembled using the Room Temperature flaring technique should be retightened to the minimum nut torque values identified in Table 1. After initial exposure to temperatures >74 C (>165 F), all SpaceSaver fitting connections should be retightened to the minimum nut torque values identified in Table 1 (fitting must be returned to room temperature before retightening). TROUBLESHOOTING Flaretek tube fitting assembly Problem Possible cause Solution After flaring the tubing, one side of the expanded portion of the tubing is wrinkled and shorter than its original length. The tubing was not heated evenly. The wrinkled areas were overheated. The wrinkles can be avoided by rotating and moving the tubing through the heat source with more uniformity. Cut off the flared tubing end and reflare. The tubing kinks when pushing it onto the flaring mandrel. The tubing was not heated properly before flaring. 1 2 to 3 4 of the tubing needs to be heated. Closely follow the recommended heating times in Table 1. Cut off the flared tubing end and reflare. When the flared tubing is pushed onto the fitting body, the tubing is more than 0.150" away from the threaded area of the fitting body. The tubing was not pushed onto the flaring mandrel all the way or the tubing was removed from the mandrel before it was cool. Tubing may need longer heating time or longer cooling time on the flaring mandrel. Cut off the flared tubing end and reflare. The flared tubing will not fit onto the fitting body. The tubing was removed from the mandrel before it was cool. Reheat and reflare the undersized flared tubing end. Allow adequate cooling time prior to removing from the flare mandrel. Or Cut off the flared tubing end and reflare. Be sure the tubing is cool before removing it from the mandrel. Changes need to be made to a line after chemical has been run through the system. There is potential for vapor explosion in the line or hazard to the operator. Heated flaring should only be attempted with tubing that has not been exposed to chemical. We recommend using the Entegris Room Temperature Flaring Tool (part number 213-112) if the tubing has been exposed to chemical. Tube connection leaks. Inadequate torque on fitting nut. Retighten according to the torque value in Table 1. Possibly damaged flare mandrel. Replace mandrel. Cut off the flared tubing and reflare. 5

TORQUE WRENCH CALCULATION When using an Entegris flare fitting wrench, the torque reading must be adjusted on the torque wrench to compensate for the wrench extension length (see Figure 5 for reference). Extension length* G = (L T) (L + E) G = Torque wrench reading (in lbs) L = Torque wrench length (inches) Wrench length T = Torque desired (in lbs) E = Extension length (e.g. 3.10 ) Example: Wrench length = 12.0 Extension length = 3.10 Torque desired = 80 in lbs Figure 5. (12 80) (12 + 3.1) = 63.58 in lbs FOR MORE INFORMATION Please call your Regional Customer Service Center today to learn what Entegris can do for you. Visit entegris.com and select the Contact Us link to find the customer service center nearest you. TERMS AND CONDITIONS OF SALE All purchases are subject to Entegris Terms and Conditions of Sale. To view and print this information, visit entegris.com and select the Terms & Conditions link in the footer. Corporate Headquarters 129 Concord Road Billerica, MA 01821 USA Customer Service Tel +1 952 556 4181 Fax +1 952 556 8022 Toll Free 800 394 4083 Entegris, the Entegris Rings Design, Pure Advantage, Flaretek and FluoroLine are trademarks of Entegris, Inc. 2005-2017 Entegris, Inc. All rights reserved. Printed in the USA 3110-2122ENT-0217 www.entegris.com