Rating Definitions and Conditions

Similar documents
Model MP150 W W

Rating Definitions and Conditions

Rating Definitions and Conditions

Model NA 2 L

Rating Definitions and Conditions

Rating Definitions and Conditions

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

STANDBY 1500 ekw 1875 kva 50 Hz 1500 rpm 400 Volts

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 650 ekw 812 kva 60 Hz 1800 rpm 480 Volts

PRIME 920 ekw 1150 kva 50 Hz 1500 rpm 400 Volts

STANDBY 720 ekw 900 kva 50 Hz 1500 rpm 400 Volts

PRIME 256 ekw 320 kva 50 Hz 1500 rpm 415 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

300 KW / 375 KVA POWERED by

STANDBY 880 ekw 1100 kva 50 Hz 1500 rpm 400 Volts

1020 KW / 1275 KVA. POWERED by TP-U1275-T2F-60. kva 1275 Standby 3 Phase - Switchable kw /208, 277/480. kva 1150 Prime Power Factor 0.

130 KW / 165 KVA POWERED by

Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

PRIME 808 ekw 1010 kva 50 Hz 1500 rpm 415 Volts

2000 KW / 2500 KVA POWERED by

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 415 Volts

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

TPD2250H6.3 TECHNICAL DATA

DIESEL GENERATOR SET FEATURES

STANDBY 200 ekw 250 kva

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

PRIME 365 ekw 456 kva 60 Hz 1800 rpm 480 Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

500 KW / 625 KVA POWERED by

PRIME 508 ekw 635 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1000 ekw 1250 kva 60 Hz 1800 rpm 480 Volts

C13. STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1250 ekw 1562 kva 60 Hz 1800 rpm 480 Volts

PRIME 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

60 KW / 75 KVA POWERED by

Diesel generator set. 50 kw - 60 kw EPA emissions stationary Standby. Specification sheet. Description. Features

STANDBY 1000 ekw 1250 kva 50 Hz 1500 rpm 400 Volts

UQ-Power Diesel Generator Set. Model: PE-91 GENERAL DATA. kw/kva Prime Power Continuous. kw/kva Standby power. kw/kva

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

350 KW / 438 KVA. POWERED by TP-V350-T1-60. kva 438 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 400 Prime Power Factor 0.

APD-NG400. NG Standby Power

70 KW / 90 KVA POWERED by

APD-ULJ250. Standby Power

130 KW / 165 KVA POWERED by

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts

STANDBY 400 ekw 500 kva 50 Hz 1500 rpm 400 Volts

CONTINUOUS 1600 ekw 2000 kva 50 Hz 1500 rpm 400 Volts

WPS150/S EP Series. Features:

C18. STANDBY 560 ekw 700 kva 50 Hz 1500 rpm 400 Volts

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

STANDBY 240 ekw 300 kva 50 Hz 1500 rpm 400 Volts

60 Hz FEATURES. Exclusively from your Caterpillar dealer

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

STANDBY 600 ekw 750 kva 50 Hz 1500 rpm 400 Volts

Diesel generator set 6BT5.9 series engine

STANDBY 600 ekw 750 kva 60 Hz 1800 rpm 220 Volts

60 Hz FEATURES. Exclusively from your Caterpillar dealer

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

Mission Critical Standby 1120 ekw 1400 kva 50 Hz 1500 rpm 400 Volts STANDBY DIESEL GENERATOR SET FEATURES

STANDBY 350 ekw kva 60 Hz 1800 rpm 480 Volts

275 KW / 344 KVA. POWERED by TP-JD275-T3F-60. kva 313 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 224 Prime Power Factor 0.

WPS60/S EP Series. Features:

Diesel generator set. 20 kw EPA emissions stationary Standby. Specification sheet. Description. Features

DIESEL GENERATOR SET MTU 18V2000 DS1400

GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

1500 KW / 1875 KVA. POWERED by TP-MT1500-T2-60. kva 1875 Standby 3 Phase kw /208, 110/220, 120/240, 277/480

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

CONTINUOUS 1230 ekw 1538 kva 60 Hz 1800 rpm 480 Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

Diesel generator set. QSB5 series engine Hz EPA Tier 3 emissions. Specification sheet. Description. Features

60 KW / 75 KVA. POWERED by. kva 75 Standby 3 Phase kw /208, 110/220, 120/240, 277/480. kva 70 Prime Power Factor 0.8 kw 55

STANDBY 200 ekw 250 kva

PRIME 725 ekw 906 kva 60 Hz 1800 rpm 480 Volts

Spark-ignited generator set

STANDBY 320 ekw 400 kva 50 Hz 1500 rpm 400 Volts

Diesel generator set QSB7 series engine

Diesel generator set QSK50 series engine

PRIME 1200 ekw 1500 kva 50 Hz 1500 rpm Volts

PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts

DIESEL GENERATOR SET MTU 16V2000 DS1000

Rental Power 4BTAA3.3 series engine

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

57 KW / 71 KVA POWERED by

PRIME 545 ekw 681 kva 60 Hz 1800 rpm 480 Volts

STANDBY 1250 ekw 1563 kva 60 Hz 1800 rpm 480 Volts

PGDLS352KW 380/ / / / / / / / /

PRIME. 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET FEATURES

STANDBY 1750 ekw 2188 kva 60 Hz 1800 rpm 440 Volts

204 KW / 254 KVA POWERED by

600 KW / 750 KVA POWERED by

STANDBY 300 ekw 375 kva 60 Hz 1800 rpm 480 Volts

PGDLS / / / / / / / / /

Standby 1200 ekw 1500 kva 50 Hz 1500 rpm 400 Volts

STANDBY 2000 ekw 2500 kva 60 Hz 1800 rpm Volts

Transcription:

Model GM125 W NA Frequency/Speed Voltage Prime Power Standby Power 50HZ/1500 RPM 230/400V 60HZ/1800 RPM 60HZ/1800 RPM 277/480V 230/400V 125 KVA 100 KW NA NA NA NA 137.5 KVA 110 KW NA NA NA NA Features Image for illustration purposes only. Engine Alternator Control Panel Base Frame MAXXFORCE, 7.2P 125, complying to the norms: ISO 3046,ISO 8528 BS 5514 and DIN 6271 WEG, GTA251AIHD, complying to the norms IEC 60034 NBR 5117 NEMA MG1 VDE530 ISO8528 CSA Deep sea, M DCM 317B,Made in UK, complying to the norms BS EN 61000, BS EN 60950, BS EN 60068 Black steel with Anti vibration pads, Built in fuel tank Sound Proof Canopy Worldwide Support Modular SPC, Powder Coated, Extremely Durable, Designed to Reduce Sound Level with Maximum Service Accessibility and Minimum Foot Prints Mets Energy Products are distributed through its PowerMets International Network For more information kindly check our website www.metsenergy.com Rating Definitions and Conditions Prime Rating Standby Rating The power available for an unlimited hour usage with an average load factor of 80% of the published prime power over each 24 hours period. A 10 % overload is available for 1Hr every 12 hours. The power limited to 500 hours annual usage with an average load factor of 80% of the published standby power rating over each 24 hour period. Up to 300 hours of annual usage may be run continuously. No overload is permitted on standby power. KVA Rating @ 0.8 P.F

Structure Engine MAXXFORCE, 7.2P 125, 4 Stroke Cycle, Diesel Number of Cylinders 6 Engine Build In line Bore 105 mm Stroke 137 mm Displacement 7.12 L Compression Ratio 16.8 /1 Aspiration Turbocharged Cooling Aftercooled 1500 rpm 1800 rpm Fuel Tank Enclosure :Built in fuel tank 447 L for 16 hours operation @ full load TBA Fuel Cooling system Air Inlet Exhaust System DC System Starting/Charging Heat Rejection(prime) Lube System Fuel System Direct injection Fuel Recommended N 2 Diesel Fuel System Make (ECM) 1500 rpm 1800 rpm Delivery Flow Rate (lr/hr) TBA NA Fuel Consumption 100% Load (g/kwh L/hr) 202 (27.13 ) NA 75% Load (g/kwh L/hr) 200 ( 20.14 ) NA 50% Load (g/kwh L/hr) 214 ( 14.54 ) NA Engine Coolant Capacity 25L Air Flow Radiator 4720 l/s NA radiator with 50 degree ambient Cooling Package & Air Cleaner Kit Thermostatically controled system Air Intake Engine(Clean Filter/Dirty) 230 / 600 mm H2O Exhaust Gas Temperature (Prime) 600 C NA Exhaust Gas Flow (Prime) 558 kg/h NA Maximum Exhaust System Back Pressure 75 mmhg NA Muffler residential (20 25 db) industrial(15 25 db) Stainless Steel exhaust flex fittings Cranking Battery Voltage 24 V Battery Charging Alternator TBA Dc Voltage Monitoring via control panel Radiated Heat to Ambient (Prime) 12.1 kw NA Heat Rejection to Coolant (Prime) 59.73 kw NA Heat Rejection to Exhaust (Prime) 82.39 kw NA Heat Rejection to intercooler (prime) 14.74 kw NA Lubricating System Oil Capacity 19.8 L

Governor Mechanical

Alternator Weg,GTA251AIHD Insulation System Class H Winding Pitch 2/3 to minimize harmonics effects Number of Poles 4 Number of Bearings Single bearing Winding Leads 12 Structure Power Factor 0.8 Over Speed Capability (% of 2250 Rpm (125%) Wave Form Distortion THD(Total Harmonic Distortion)@ No load < 5.0% Telephone Interference TIF < 3% IP Rating (Protection) IP21 AVR Excitation with auxiliary coil Synchronous, 3 phase, Brushless & Self ventilated 1500 rpm 1800 rpm Power Switching 3 P Circuit Breaker, MCCB 200A NA Temperature Temperature Rise 125/40 C Control System (Standard) Excitation with auxiliary coil Control & Voltage Voltage Regulator (AVR) GRT7 TH4E(5A E9) Regulator % Of Voltage Regulation ± 0.5 % if voltage 230/400V TBA Motor Starting Capacity@30% Voltage Dip if voltage 277/480V TBA

Control Indications Warning & Shutdown Alarms Features Alternator Power Switching Standard Controller, M DCM 317 Auto/Start/Stop Control Emergency Stop Pushbutton/ Alarm Acknowledge Engine Cool Down Timer Warm up Timer Load Switching Timer Engine Cycle Crank Operating Hours 3 Phase Generator Voltage Sensing & Monitoring Current Protection & Monitoring Power Measurement (kw, kva, kvar, kwh, kvah, kvarh, pf) Frequency Monitoring (Hz) Oil Pressure/Coolant Temperature/Fuel Level Monitoring Battery Voltage Monitoring (DC) Alarm Acknowledge Generator Over/Under Voltage & Frequency Crank Disconnect (Failure to Start) Under/Over Speed Over Current Low oil pressure High Water Temperature Low Fuel Level Low Water Level IP 65 (if ordered with gasket) Basic Scheduler 8 35 VDC Supply Digital Inputs(4) Outputs(4 MPU/ 6 CAN) Event Log (5 shutdowns) Optional Accessories AVR (3 phase Sensing) Reactive Droop Winding Temperature Detectors Anti Condensation Heaters Excitation with auxiliary exciter (PMG) 4 P Circuit Breaker Special Brands (ABB MG Siemens...) Motorized Operation Shunt Trip Under Voltage Trip UVT Residual Current Protection Ground Fault Protection Earthing Kit Surge Arrestor

Engine Control Panel Fuel Air Inlet Exhaust Cooling / Heating Lube DC System Starting/Changing Optional Accessories (continues) Micro Diesel Filter for Micro Particles Filtration Automatic Fuel Refilling System Fuel Water Separa(2000/40) Mechanical Fuel Level Kit Oversize Fuel Tank Upon Custom Requirements Fuel Tanks Pipes Heater Sy klone Air Cleaner Installed @ Air Intake System Muffler: Critical (25 30 db) Hospital (35 40 db) Elbow, Flanges, Expanders & Y Adaptors Radiator with 35 C or 60 C Ambient Capability Jacket Water Heater Manual Sump Drain Pump Semi Rotator Hand Pump Mains Battery Charger 24 V DC 5A Battery Charger 10A 20A on Request Automatic Battery Charger on Request Battery Disconnector Switch DC/AC Current Monitoring (Ammeter) Oversize Battery DSE 7310/7320/7410/7420 More Inputs & Outputs Advanced Communications Features; DSE 8610/8710/8810 Load Share Module; Digital & Analogues Inputs Module DSE 2130 (for 7000 Series & Above); Analogue Inputs advanced Module DSE 2131 2133(for 7410 &Above); Digital relay Outputs Module DSE 2157 (for 7000 Series &Above); Analogue Outputs Module DSE 2152 (for 7410 & Above); Local & Remote enunciator Module DSE 2548 (for 7000 Series & Above); Display Modules DSE 2510/2520 (with 7310 7320); Remote Monitoring via: Web Interface (All Series), GSM (for 7000 Series & Above), RS485 Dry Contacts Alarm Indication for Customer Use Audible Alarm (Option for 6010/20; Standard for 7000 Series & Above); Voltage Adjust Potentiometer; Speed Adjust Potentiometer;

Dimensions & Weights Height (mm) Length (mm) Width (mm) Weight Dry "A" Open set (NB) 2720 1200 1730 1460 SPC Type S 4280 1210 2136 2031 Drawings for illustration purposes only. WWW.METSENERGY.com