DEVELOPMENT & OPERATING EXPERIENCE WITH SGT-800, A SIEMENS 45 MW INDUSTRIAL GAS TURBINE FOR VARIOUS APPLICATIONS

Similar documents
SGT-700 DLE combustion system extending the fuel flexibility

THE SIEMENS SGT-750 GAS TURBINE: DEVELOPED FOR THE OIL AND GAS INDUSTRYAnders Hellberg Siemens Industrial Turbomachinary S Finspong Sweden

SGT5-8000H/SCC5-8000H 1S. First experience of Commercial Operation at Irsching 4. Russia Power Moscow, March

Meet the SGT-750. Proven technology. Perfected results. 37 MW. Answers for energy. Industrial Gas Turbines

REPORT ON THE FIRST OPERATIONAL EXPERIENCE OF THE NEWLY COMMERCIALIZED 29MW SGT-700 (GT10C) GAS TURBINE

Paper No: 05-IAGT-1.1 INDUSTRIAL APPLICATION OF GAS TURBINES COMMITTEE

Power Generation Services Solutions for challenging Markets

SGT-2000E gas turbine series

SGT5-8000H / Irsching 4 Siemens H class gas turbine Pioneering efficiency with world class flexibility

H Class High Performance Siemens Gas Turbine (SGT-8000H)

We power the world with innovative gas turbines

Technology Application to MHPS Large Frame F series Gas Turbine

SGT-2000E gas turbine series

EXPERIENCE OF 29MW SGT-700 GAS TURBINE IN POWER GENERATION APPLICATIONS

Siemens SGT6-5000F Gas Turbine Technology Update

Aircraft Propulsion Technology

Heavy-duty Gas turbines

Latest Developments in Siemens Large Gas Turbine Portfolio. Matthias Fränkle 8000H Product Manager

STEAM TURBINE MODERNIZATION SOLUTIONS PROVIDE A WIDE SPECTRUM OF OPTIONS TO IMPROVE PERFORMANCE

SGT5-8000H - Product Validation at Irsching 4 Test Center. Dr. Roland Fischer Phil Ratliff Willibald Fischer. Siemens AG, Energy Sector Germany / USA

RIKT 71 Isothermal Turbocompressor

The SGT5-8000H proven in commercial operation

Operating Results of J-series Gas Turbine and Development of JAC

Extended fuel flexibility capabilities of the SGT-700 DLE combustion system

The Enhanced Platform

Table of Contents. 4. Before a New Turbocharger is Installed

SGT5-2000E Latest Service Improvements for Optimized Operations, Maintenance and LNG Fuel Conversion Upgrade Grit Hennig

Siemens Industrial Gas Turbines 斯奥动力集团 SOAR POWER GROU P

Variable Intake Manifold Development trend and technology

SGT-200 (Tornado) CAPABILITY OVERVIEW DMEnergy (Generation Service) Tel.: +7 (499) Web: dm.

Beyond 60% - Pioneering H-class Efficiency with World Class Flexibility

Artesis MCM Case Studies. March 2011

ADVANTAGES OF GTE s Weight reduction of 70% Simplicity Reduced manning requirements Quicker response time Faster Acceleration/deceleration Modular rep

FUNDAMENTAL SAFETY OVERVIEW VOLUME 2: DESIGN AND SAFETY CHAPTER E: THE REACTOR COOLANT SYSTEM AND RELATED SYSTEMS

Corso di Motori Aeronautici

Development of Two-stage Electric Turbocharging system for Automobiles

Development of TPL and TPS Series Marine Turbocharger

Efficient, dependable and off the shelf. Pre-engineered gas-turbine driven pipeline compressor packages. Answers for energy.

Technologies to Reduce GT Emissions

LMS100 Gas Turbine System

When should an Electric Adjustable Speed Drive be used instead of a Gas or Steam Turbine? Paul Blaiklock, Manish Verma, Stephan Bondy

CASE STUDY ON RESOLVING OIL WHIRL ISSUES ON GAS COMPRESSOR

First Domestic High-Efficiency Centrifugal Chiller with Magnetic Bearings: The ETI-MB Series

Mature technology for 400 MW class CCPP

Industrial RB211 Gzero Gas Turbines

Sulzer Dowding & Mills

built for the next generation Cat

How do you build a great idea? The optimised standard in industrial gear unit technology. FLENDER SIG horizontal standard gear units. siemens.

Design and Test of Transonic Compressor Rotor with Tandem Cascade

AGN 076 Alternator Bearings

WET COMPRESSION. What it Is Not. What it Is. Is not traditional inlet air cooling, like a fogger or a chiller

Global VPI Insulated Indirectly Hydrogen-Cooled Turbine Generator for Single-Shaft Type Combined Cycle Power Generation Facilities

Study on Flow Fields in Variable Area Nozzles for Radial Turbines

ROTATING MACHINERY DYNAMICS

DYNAS3 LEADING SOLUTIONS FOR DYNAMIC ENGINE TESTING. Explore the future

MAN Technical Symposium 2016 MAN Turbochargers Ready for tomorrow

COMBUSTION TURBINE LOSS PREVENTION GUIDELINES

ABB MEASUREMENT & ANALYTICS. Predictive Emission Monitoring Systems The new approach for monitoring emissions from industry

ALCOHOL LOX STEAM GENERATOR TEST EXPERIENCE

Engineering Success by Application of STAR-CCM+ for Modern Gas Turbine Design

Pressurized Air Cooled Generators

Power-GEN Middle East

Ignition Reliability in SGT-750 for Gas Blends at Arctic Conditions. Magnus Persson Combustion Expert / Distributed Generation / Sweden

Rolls-Royce Corporation 501-D22 COMMERCIAL ENGINE BULLETIN (CEB) Technical Publications Index

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

MSFI TECHNOLOGY AT SAFRAN AIRCRAFT

Is Low Friction Efficient?

Metrovick F2/4 Beryl. Turbo-Union RB199

November 8, 2018 GAS TURBINE ENGINE SECONDARY FLOW SYSTEMS

Fuels, Combustion and Environmental Considerations in Industrial Gas Turbines - Introduction and Overview

SP A, SP. Submersible pumps Submersible motors Accessories. 50 Hz

SKF Explorer spherical roller bearings Optimized for superior field performance

Modification of Kiln Plants to Meet Russian Demands

APPLICATION OF STAR-CCM+ TO TURBOCHARGER MODELING AT BORGWARNER TURBO SYSTEMS

FISCAL YEAR MARCH 2015 FIRST HALF FINANCIAL RESULTS. New Mazda Demio

Generators for the age of variable power generation

9 th Diesel Engine Emission Reduction Conference Newport, Rhode Island, August 2003

Lessons in Systems Engineering. The SSME Weight Growth History. Richard Ryan Technical Specialist, MSFC Chief Engineers Office

Training Title GAS TURBINE AND COMPRESSOR OPERATION, MAINTENANCE AND TROUBLESHOOTING

B. HOLMQVIST Nuclear Fuel Division, ABB Atom AB, Vasteras, Sweden

17-IAGT-104 Siemens introduces the SGT-A45 mobile unit: superior performance with trusted technology

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

Development of Low-thrust Thruster with World's Highest Performance Contributing to Life Extension of Artificial Satellites

New Alpha CP Propellers A high-efficient VBS Mk 5 design is revealed at SMM

Retrofitting of Mitsubishi Low NOx System

AE94.3A Flexibility Upgrade

MD High Pressure Stage Casing Pump

Pump Coupling & Motor bearing damage detection using Condition Monitoring at DTPS

Proven to be better. Development trends in industrial rolling bearings

Guardian Packing Rings. Vortex Shedder Seals. Turbine Components. Custom Installation. Reverse Engineering

SOGIC May 8, 2018 Hyatt Regency, Calgary, Alberta

Turbocharger Warranty Analysis Guidelines

D G A G R I D A S H B O A R D : A P P L E S

Chromalloy. Borescope and Test Report. Prepared for. Triumph Air Repair A Triumph Group Company

ALSTOM WORLD WIDE EXPERIENCE OF STEAM TURBINE RETROFITS ON NUCLEAR POWER PLANTS. May 2015

RIKT Isothermal Turbocompressors. With integrated cooling

World s Largest Air-cooled Turbogenerator in operation

THE TURBO FOR THE AFTERMARKET. EXHAUST GAS TURBOCHARGERS FROM MAHLE

GE s LM2500+G4 Aeroderivative Gas Turbine for Marine and Industrial Applications

TurboPHASE: Cost- Effective and Efficient Peaking Power

Transcription:

DEVELOPMENT & OPERATING EXPERIENCE WITH SGT-800, A SIEMENS 45 MW INDUSTRIAL GAS TURBINE FOR VARIOUS APPLICATIONS Thomas Hagerstål Jan Wikner Siemens Industrial Turbomachinery AB SE-612 83 Finspong, Sweden ABSTRACT This paper describes the development steps of the advanced industrial gas turbine SGT-800 (former GTX100) - including initial driving factors, selection of design principles, performance & emission data, features &benefits, validation testing and commercial introduction. It also highlights the experience and status of the current fleet of plants in commercial operation as well as results from the latest inspections, carried out during year 2004/2005.

INTRODUCTION The concept study of SGT-800 started year 1994 - a result of an extensive market survey of customer requirements, general market trends, potential future sales volumes and competition. Our conclusion from this survey was that there was room for another gas turbine in the 35-50 MW class, provided that it had attractive features and a strong organization to support the product. The selling volume was at a level of 100+ units/year with just a few strong players on the supply side. The forecast showed a rising trend for deliveries in the abovementioned size range, with Combined Heat and Power/Combined Cycle-applications for electric power and hot water/steam production dominating in the long term perspective. Since the commercial launch of the SGT-800 in May 1997, 46 units have been sold to 16 countries (Austria, Belgium, France, Germany, Iran, Italy, Kazakhstan, Latvia, Portugal, Russia, Slovenia, Sweden, Turkey, UK, USA and Venezuela). The accumulated number of equivalent operating hours for 19 units in commercial operation is 320 000+, with 8 units above 20 000 and the "fleet leader" 35 000+ (as per Dec 2005). Remaining units are in manufacturing or at site in erection/commissioning phase. DRIVING FACTORS INFLUENCING THE FINAL DESIGN OUTLINE The customer requirement part of the market survey gave important input to the development project and these requirements coincide with those which are the focus of in a normal Total Cost of Ownership analysis. Requirement "Buzz" words First investment cost for the Plant Cash flow, IRR, NPV = design to cost (IRR = Internal Rate of Return, NPV = Net Present Value) Quick delivery from order to commercial Cash flow, IRR, NPV = standardization, supply operation logistics Reliability Availability Maintainability (RAM) "Uptime", design simplicity, durability, service concept Cycle efficiency Cost of fuel, "greenhouse", CO 2 taxes Emissions (NOx, CO, VOC, UHC, PM10..) BACT, Air permits, hourly/daily/yearly caps (BACT = Best Available Control Technology) Operational flexibility without restrictions in the Base/intermediate/peak operation, DLE simplicity, load range stable controls Full load rejection capability without trip Single shaft for inertia, island mode capability Fuel capability Wobbe-index range for gas fuel, gas/liquid fuel capability with quick changeover "on the fly" Service life & component life Long time between inspections/overhauls, maintenance cost All these requirements and "buzz" words were addressed in the design criteria for the development project.

DESIGN CONSIDERATIONS TO MEET THE DRIVING FACTORS Initially, there were a number of important technical "power string" decisions to make, based on the information available from the market and in-house knowledge. Some of these decisions were difficult ones with "pros and cons" to be evaluated and concluded. Power Output Matching the market demand and the competition at the time of commercial launch and also having a growth capability in the design Heat rate (efficiency) World class in Combined Heat and Power/Combined Cycle and best industrial in Simple Cycle in the 35-50 MW class. Emissions 15 ppmv/natural gas and 42 ppmv/diesel #2 (without wet injection) @ 15% O 2 in the 50-100% power range, with capability to go to single-digit in the future without change of DLE combustion system. Pressure ratio and TIT. A pressure ratio/tit combination selected to optimize the heat rate (efficiency) for the promoted applications. The importance of a low pressure ratio was also recognized as it is linked to the required engine gas fuel pressure and the possible need for a "boosting" compressor in the external gas fuel system (extra auxiliary power consumption). 1- or 2-shaft gas turbine. 1-shaft unit promotes simplicity in design (1 compressor, 1 combustion chamber, 1 turbine and 2 bearings), compactness and has high inertia to handle large load steps up and down plus island mode operation without trip. 2-shaft is normally quicker to start, needs less starting power and is more suitable for MD operation (variable speed on power shaft). Compressor Subsonic or transonic inlet? The use of a transonic compressor inlet results in fewer compressor stages for a given pressure ratio, i.e. a more compact compressor. The current trend today for compressors is to use a transonic inlet, however with a conservative Mach-number for surge margin and acceptance of fouling. Electron Beam-welded (one-piece) or stacked rotor with heated central tie-bolt or hydraulically stretched tie-bolts on a radius. EB-welded rotor gives low vibrations, straight-forward torque transfer, good control of blade tip clearances and still the possibility to replace individual blades in-situ, provided that casings in the compressor section have a longitudinal split. Combustion system Stacked rotor with tie-bolts allows casings to be non-split at compressor assembly/disassembly, smaller pieces to repair/replace in case of damage, better inspection possibilities at overhauls, requires detailed analysis to avoid loose fits between individual parts during start, steady state and shutdown. Conventional or Dry Low Emission or both concepts? Conventional. Good fuel flexibility, higher emissions DLE. Moderate fuel flexibility, lower emissions Both concepts. Alternative variants on core engine and the rest of the package can contribute to lower availability for the overall fleet more options to handle for the supporting organization. Annular or can-annular type? Annular requires less cooling air due to less hot surface area and gives a better flow inlet into the turbine. Simple cross-ignition during start-up. Acoustics due to flame instability at ultra-low emission levels can be more difficult to cure. Maintenance concept must be adapted for single piece removal. Turbine Can-annular requires more cooling air, cross-over tubes for start-up alternatively one igniter per can, transition ducts for flow inlet to the turbine. Single cans can normally be removed without removal of the turbine module. 3- or 4-stage? 3-stages less cooling air, slightly lower turbine efficiency, lower production cost. 4-stages more cooling air, slightly higher turbine efficiency, higher production cost. The overall gas turbine efficiency becomes equal in the SGT-800 case.

Flexible service concept Service in situ without moving engine from its supports and/or engine swap, i.e. customer choice (figure 1). Hot section disassembly Remove outer and inner cone 1 Remove diffuser 2 casing Remove turbine casing 3 Remove turbine module 4 Remove burners, 5 and 1st guide vane cone and combustion Compressor disassembly GT removal On roller skates to external support structure 2-pole or 4-pole AC generator An early decision was taken to use a 4-pole AC generator for compact plant foot-print, sub-critical speed operation and lower production cost for the rated power. Starting arrangement through the AC generator or separate arrangement on the power shaft A separate arrangement was favored to give flexibility on selection of generator brand and type and also the possibility to serve the mechanical drive market with alternative driven objects, without a major redesign. Figure 1 Service Concept in Situ The final selection of design principles for the core engine is shown later in this paper.

FEATURES & DATA The General Arrangement drawing for the Simple Cycle version with dimensions is shown below. In Combined Heat and Power/Combined Cycle, the exhaust is cut off at the flange downstream of the turbine diffuser (measure O ) and connected to either a diverter valve for by-pass stack applications or directly to the Waste Heat Recovery Boiler. The location of the exhaust silencer is often customized for CHP/CC-applications, depending upon site space and noise requirements. The Electrical and Control module seen on the right hand side picture is optional as a Central Control Room for the whole plant is often used to collect all E&C equipment at one place. Figure 2 Layout Overview

Figure 3 Cross Section and Main Features of the SGT-800 core engine Annular CC with 30 dual fuel DLE burners Bearing #1 (radial + thrust) Engine inlet 15 stage compressor 3 stages variable guide vanes Bearing #2 (radial) Engine exhaust diffuser Drive shaft to gear box 6600 rpm 3 stage turbine The design philosophy has been based upon simplicity, robustness and the use of proven technology. The SGT-800 has a frame design with a minimum number of parts in a single-shaft arrangement. The compressor rotor and the three-stage bolted turbine module form a single shaft, which rests in two hydrodynamic bearings of the tilting pad type. The 4-pole generator is driven through a speed reduction gear from the cold end of the gas turbine which allows for a simple and efficient exhaust arrangement. Modularization, few parts, long component life and easy inspection ensure long time between overhauls and low maintenance costs. DATA Number of shafts 1 Drive shaft position Cold end Type of compressor Axial flow, transonic inlet Number of compressor stages 15 stages total (3 stages with variable guide vanes) Number of compressor extractions 5 (3rd, 5th, 8th, 10th and 15th stage) Pressure ratio 19:1 (at ISO and natural gas ) Type of turbine Axial flow Number of turbine stages 3 (film cooled stage #1, convection cooled stage #2 and non-cooled stage #3) Turbine inlet temperature 1180 C // 2156 F (ISO2314, average thermodynamic mixed gas temperature). Engine weight 36000 kg // 79380 lbs Engine rotor weight (incl. blades) 7860 kg // 17300 lbs Rotor construction Electron beam welded compressor, bolted turbine discs Nominal engine rotor speed 6600 rpm (after gear 1500 rpm/50 Hz & 1800 rpm/60 Hz with 4- pole Generator) Thrust bearing type Tilting pad (forced lubrication) Journal bearing type Tilting pad (forced lubrication) Type of combustion chamber 3 rd generation DLE (dry), annular combustion chamber Number of burners 30 Burners Type Single fuel or dual fuel (annular combustion chamber) Nominal emissions Natural gas: NOx: 15 ppmv @ 15% O 2, CO: 5 ppmv (no water injection, 50-100% load range) Diesel #2: NOx: 42 ppmv @ 15% O 2, CO: 5 ppmv

Performance Simple cycle Combined cycle Nominal output, ISO, natural gas 45 MW 63.9 MW (net) Nominal heat rate, ISO, natural gas 9730 kj/kwh 9224 Btu/kWh 6792 kj/kwh (net) 6440 Btu/kWh (net) Nominal efficiency, ISO, natural gas 37.0 % 53.0 % (net) Nominal exhaust flow 130.4 kg/s // 287.4 lbs/s (at ISO and natural gas) Nominal exhaust temperature 538 C // 1001 F (at ISO and natural gas) Development phases Concept ready Issues / Remedies Validation tests for continuous improvements in Helsingborg Design, validation, manufacturing 500 hrs endurance test 1995 1996 1997 1998 1999 2000 2001 2002 2003 2004 2005 Launch to market 1 st unit sold 1 st unit started 46 units sold Figure 4 SGT-800 Development and Status time line The timeline of the development phases is shown above. After the first unit startup in November 1999 and the clearance of some initial issues a successful 500 hours endurance test was carried out in mid 2000. The plant in Helsingborg (Västhamn) has been used during the summer seasons for validation of continuous improvements, mainly related to fine-tuning of emissions over a load range but also for a "crystal test", which will be briefly explained later in this document (please see validation of design). VALIDATION OF DESIGN The initial design validation was done by cold and/or hot testing of core engine components and modules rather than a complete package to catch any issues as early as possible. The complete package was tested with 1550 extra instruments (approx. 200 through telemetry) at the end of 1999. A number of component upgrades have been introduced since the original launch and a new fingerprint of the complete turbine section was taken during a comprehensive measurement in 2003.

CRYSTAL TEST In mid 2003 a full engine test was carried out with a temperature-sensitive crystal technique, which gives an excellent mapping of the temperature distribution in turbine vanes and blades (Reference [1]). As it is possible to install many crystals on a single component, the temperature gradient can be established which is essential for thermo-mechanical fatigue analysis of components with advanced cooling. The instrumentation used in this test included more than 2300 measuring points, complemented with thermal paint. A total number of 1975 thermo-crystals, 237 thermocouples and 110 pressure taps were used for the test of the 3-stage turbine. The 1975 thermo-crystals measured both metal temperature (1855 off, yield rate during test 95%) and gas path temperature (120 off, yield rate during test 80%) The metal temperatures were measured by installing crystals, using a thermo-cement technique to glue the crystals into the grooves and the gas path temperatures were measured by placing crystals on extended ceramic pins attached to the leading edge of rotating blades and stationary vanes. The accuracy of the method is claimed by the crystal supplier to be +/- 10 C (+/- 18 F). This has been verified by blind tests for some crystals which had been put in an oven at our laboratory with accurate temperatures and holding times and afterwards sent away for evaluation. This experiment confirmed the claimed accuracy. The measuring interval is from 200 C (390 F) to 1400 C (2550 F). For high temperatures the exposure time is limited and the full engine test was carried out for 20 minutes on full load. The test showed that there was a good correlation between measured and calculated temperatures. For turbine blade stage 2, the largest difference found (max-min) for a single point was 35 C (63 F) and the average difference (max-min) for similar points at different blades was 10 C (18 F) (figure 5). Figure 5 Thermo-crystal Measurements, Turbine blade, stage #2 This test, discussed in detail in Reference [1], and the obtained results, enables us to further optimise the blade cooling for component life and cycle efficiency improvements.

COMMERCIAL INTRODUCTION AND STATUS OF FLEET The commercial launch to the market took place in May 1997 at four strategic places in the world and the first SGT-800 orders were placed in August 1998 (1 unit in Sweden and 2 units in France). The first commercial order reached full load in November 1999. Since the commercial launch of the SGT-800 in May 1997, 46 units have been sold to 16 countries. The accumulated number of equivalent operating hours for 19 units in commercial operation is 320 000+, with 8 units above 20 000 and the "fleet leader" 35 000+ (as per Dec 2005). The current Availability and Reliability is 95 % respectively 98 % (12 months rolling average, Nov 2004-Oct 2005) for the reporting fleet, which is in line with our expectations. These figures were achieved without any engine swaps. The starting reliability over the same period is 86%, with an improvement program ongoing, including a change to ignition sparks plug to raise the start reliability to 95%. MAINTENANCE PROGRAM AND INSPECTION RESULTS 2004 Inspections and overhauls of the "core engine" are governed by an Equivalent Operating Hours (EOH) and an Equivalent Operating Cycles (EOC) formula on a Come-First basis. Continuous base load units are "triggered" by EOH, while frequent start and stop units are normally "triggered" by EOC. The standard Maintenance Program over 120 000 EOH / 6000 EOC (approximately 15 calendar years) is shown below (figure 6). The downtime for planned maintenance in a base-load application is approximately 2% as an average over the 120 000 EOH period without use of a swap engine at Level B, C and D. Level D Level C Level B Level A Operation Maintenance Overhaul + AC Generator check Overhaul Recondition Borescope Daily Weekly Monthly 10 20 30 40 50 60 70 80 90 100 110 120 Eq. Op. Hrs x 1000 The vital hot section components (combustion chamber and blades/vanes), have a design life of 40 000 EOH/2000 Figure 6 Maintenance EOC (with margin) Plan and some of these components are coated, either by Thermal Barrier Coating (TBC) or by Pt-Al alternatively M-Cr-Al-Y, calling for "strip" and "re-coat" at half time. As a "strip" and "recoat" activity takes time and short outages are essential. A swap of the complete "hot" turbine module is an attractive alternative for reduction of outage time at Level B, C and D interventions with some impact on the service cost. INSPECTION RESULTS 2004/2005. The Level B-inspections at 20 000 EOH have been carried out on 6 units during year 2004/2005 according to the Maintenance Plan. Reconditioning of combustion chamber, turbine vane #1, turbine blade #1 and turbine vane #2 is scheduled at this event. Unit #1, season operation Unit #2, base-load operation Unit #3, season operation

Unit #4, season operation Unit #5, base-load operation Unit #6, intermediate-load operation The units were generally in good condition with only a few observations on parts not included in the ordinary Maintenance program - in excess of normal fouling, wear and tear: Unit #1 Small impact damages on 8 blades in compressor stage #12 - #15, excess wear on the end piece of one torch igniter (used for start-up), 6 burners had some material loss around the pilot gas injection holes. The deviating parts were corrected or exchanged as required. Unit #2 Dust inside the GT-enclosure due to failed ventilation inlet filter, dark color on tilting pads in bearing #1 and #2, some carbonized oil at bearing #2, some wear of the abradable coating in the stator at blade tips stage #5 to stage #15, some burners had clogging of pilot gas injection holes and minor cracks at this location, dust particles in the turbine area, small dents from foreign object on 4 blades in stage #2. The ventilation inlet filter, all burners and the 4 blades in stage #2 were replaced and the mineral oil was changed. Unit #3 2 out of 3 pipes in the combustion chamber pulsation system broken, issues with propane ignition system, dents in caulked in sealing strips at bearing #2. The broken pipes were replaced and clamping changed, ignition system converted to run on natural gas (instead of propane) and sealing strips repaired. Unit #4 Oil leakage from bearing #1 through one of the struts in the compressor inlet, repaired by welding. Unit #5 No special remarks Unit #6 Loss of paint on the inlet bell-mouth, minor cracks in the external casing insulation, wear of cooling sleeves and heat shields in the turbine stator. All parts with deviations were exchanged or repaired. These observations were fed into the engineering department for further investigation of root cause and possible need for future improvement. SUMMARY The introduction of the advanced industrial gas turbine and its route to maturity has been successful. After some initial "teething" issues at first startup in end of 1999, the commercial plants have been operating well. Some design updates have been done en route in the hot section part of the core engines for emission tuning over a load range and for increase of turbine stage #1 component life to the stated level in the Maintenance Plan. The latest Level B-inspections show that the life criteria of components are met as outlined in the Maintenance Plan. REFERENCES: [1] GTX100 Turbine Section Measurement Using a Temperature Sensitive Crystal Technique. A Comparison With 3D Thermal and Aerodynamic Analyses (Mats Annerfeldt, Sergey Shukin, Mats Björkman, Agne Karlsson, Anders Jönsson, Elena Svistounova, Siemens Industrial Turbomachinery AB, Finspong, Sweden), presented at PowerGen Europe, Barcelona May 2004.