DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: NATURAL LIGHT ENERGY SYSTEMS

Similar documents
DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: VELUX AMERICA LLC POST OFFICE 5001 GREENWOOD, SOUTH CAROLINA 29648

LEGACY REPORT. (800) (562) A Subsidiary of the International Code Council

ESR ICC Evaluation Service, Inc. Issued December 1, 2006 This report is subject to re-examination in one year.

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued May 1, Legacy report on the 1997 Uniform Building Code

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

DIVISION: METALS SECTION: COLD-FORMED METAL FRAMING REPORT HOLDER: WARE INDUSTRIES D/B/A MARINO\WARE

REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9050 CENTRE POINTE DRIVE, SUITE 400 WEST CHESTER, OHIO EVALUATION SUBJECT:

Trusted ICC ES. Conformity! Look. Evaluation. ICC-ES Evaluation

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: CONSOLIDATED SYSTEMS, INC. (CSi )

Originally Issued: 09/26/2012 Revised: 09/29/2017 Valid Through: 09/30/2018

DIVISION: METALS SECTION: METAL FASTENINGS SECTION: STEEL DECKING REPORT HOLDER: ITW BUILDEX

REPORT HOLDER: JAMES HARDIE BUILDING PRODUCTS INC ELM AVENUE FONTANA, CALIFORNIA EVALUATION SUBJECT:

continuous mounting flange intended for direct attachment to roofing substrate.

ICC-ES Evaluation Report

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: 2100 REXFORD ROAD CHARLOTTE, NORTH CAROLINA EVALUATION SUBJECT:

EVALUATION SUBJECT: >B< MAXIPRO PRESS FITTINGS FOR AC AND REFRIGERATION APPLICATION

Product Evaluation Report

PRODUCT EVALUATION Effective Date: July 1, 2014 RC-20

EVALUATION SUBJECT: CAST IRON SOIL PIPE AND FITTINGS

EVALUATION SUBJECT: GASTITE FLASHSHIELD METALLICALLY SHIELDED CORRUGATED STAINLESS STEEL TUBING

ESR ICC Evaluation Service, Inc. Issued September 1, 2007 This report is subject to re-examination in one year.

Originally Issued: 09/09/2014 Revised: 09/13/2017 Valid Through: 09/30/2018

EVALUATION SUBJECT: EPA WATERSENSE HUNTER INDUSTRIES WEATHER-BASED IRRIGATION CONTROLLERS

Code Compliance Research Report CCRR-0258

CITY OF LOS ANGELES CALIFORNIA

ESR-1414 Reissued October 1, 2011 This report is subject to renewal in one year.

National Evaluation Service, Inc.

SINGLE SLIDING WINDOW 1000 SERIES 4-1/2" FRAME SINGLE SLIDER LIFT OUT

Tubular Daylighting Device with Proven Performance

Equivalency Evaluation to 2010 FBC

Equivalency Evaluation to 2010 FBC

SAVING ENERGY SEAMLESSLY FULLY ENCAPSULATED SKYLIGHT

Residential skylight sizes 2008 edition

UNDERSTANDING FIREBLOCK

MAJESTIC SLATE CLASS A ECOSTAR GOLD STAR ROOF SYSTEM SPECIFICATIONS

TEST REPORT. Report No.: G Rendered to: VELUX America LLC Greenwood, South Carolina

AAMA/WDMA/CSA 101/I.S.2/A440-08

EVALUATION SUBJECT: EPA WATERSENSE SHOWERHEADS

Submittal Requirements for Product Evaluation - Doors

ESR-2408 Reissued August 2014 This report is subject to renewal August 2015.

TECH BULLETIN. SIP No. Subject: Fiber Cement Siding from James Hardie. Date: February 2010 (Revised November 2015)

ESR-1414 Reissued July 2014 This report is subject to renewal October 1, 2015.

4.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology

BIRDVIEW SKYLIGHTS The Clear Choice

EVALUATION SUBJECT: KITCHEN AND VANITY CABINETS

AAMA/WDMA/CSA 101/I.S.2/A440-08

CREEK Technical Services, LLC

Installation Instructions

FIXED SKYLIGHTS. A skylight in every shape and size. SERIES SI5006

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

A. This Section includes the following types of sectional overhead doors:

CREEK Technical Services, LLC

Meeting Residential Energy Requirements with Wood-Frame Construction

Not to be distributed outside of FM Approvals and its affiliates except by Customer

SENECA SHAKE TILES ECOSTAR GOLD STAR ROOF SYSTEM

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

2.0E ES LVL U.S. Design Manual

Maximum Span Tables. for Joists and Rafters. MSR Lumber. for Performance. Figure provided courtesy of the American Forest & Paper Association

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. Model A-FS-CM-SP Skylight Skyco Skylights

DASMA DASMA

3.0 RAIL-FREE RACKING. Utilizes EcoFasten Solar s patented technology

Project Number 56b January Hard Cab Design for HMMWV

Residential skylights

AAMA/WDMA/CSA 101/I.S.2/A TEST REPORT. Rendered to: MASTER WINDOW SYSTEMS, INC.

ASTM E 1886 and ASTM E 1996 TEST REPORT. Report No.: A Rendered to: GLASSCRAFT DOOR COMPANY Houston, Texas

MAJESTIC SLATE ECOSTAR GOLD STAR ROOF SYSTEM

2.0 RAIL FREE SOLAR ROOF MOUNT. Utilizes EcoFasten Solar s patented technology

Not to be distributed outside of FM Approvals and its affiliates except by Customer APPROVAL REPORT. Skylight. VELUX America LLC

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

EVALUATION SUBJECT: CERAMIC PLUMBING FIXTURES

New Gateway 101/I.S.2/A440

Commercial skylights. Dynamic Dome skylight. whyskylights.com

TECHNICAL DATA SHEET Artisan Lap Siding

By CNP INDUSTRIES, INC. P.O. Box Anaheim, Ca (877)

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

Residential pan and self-flashed skylights edition

Industrial and Stainless Steel Track and Hardware Pg 53. Straight Sliding Industrial wood. Door Hardware metal

OptiDome COVER OPERATION AND MAINTENANCE MANUAL

SSK.1.3 Sound level shall not exceed 86 db(a) at 22.86m (75 ft.). See Section 19.5 (pg. 78).

SLIDING DOOR SYSTEM_ AIR TECHNICAL BOOK. System description Accessories

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

TRUS JOIST BEAMS, HEADERS, AND COLUMNS

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C. SERIES/MODEL: SS 145.

Remodeler. Complete product = Frame-in kit + Adjustable light engine / Trim Order each separately

SolarSheat Wall Installation Manual

James Aircraft. INDUCTION SYSTEM, CARBURETED Please read all instructions prior to starting

NFRC U-FACTOR, SHGC / VT, CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. Rendered to: EARTHWISE GROUP, L.L.C.

5830 Skylight, Solar Smart Retrofit Installation

INSTALLATION, OPERATION + MAINTENANCE

2 Rubber Bumper GSM MM nut GSM30201 K9-F18-PT_INST_4-16

Durulite Door Hardware Manual

western for products manufactured in White City, Oregon


MAJESTIC NIAGARA SLATE ECOSTAR GOLD STAR ROOF SYSTEM

"CLARITY WALL" VIF " 1 1 8" SECTION 1 2 " 3 8 " "CLARITY" SLIDING DOOR with FIXED GLASS PANEL BLOCKING & SUPPORT AS NEEDED SCHEDULED CEILING

SFI SPECIFICATION 6.1 EFFECTIVE: FEBRUARY 26, 2014 *

Expanding Your Solutions. ViperStud Product Catalog. Interior Non-Load Bearing Studs and Track

NFRC U-FACTOR, SHGC, VT, & CONDENSATION RESISTANCE COMPUTER SIMULATION REPORT. (Revised) Rendered to: SPECIALTY WHOLESALE SUPPLY

LEXUS RC 350/RC-F ILLUMINATED DOOR SILLS Preparation

Renogy MTS-TM100. Flat Roof Tilt Mount E Philadelphia St, Ontario, CA Version: 1.1

Transcription:

0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3681 Reissued 01/2018 This report is subject to renewal 01/2019. DIVISION: 08 00 00 OPENINGS SECTION: 08 62 00 UNIT SKYLIGHTS REPORT HOLDER: NATURAL LIGHT ENERGY SYSTEMS 10821 NORTH 23 RD AVENUE PHOENIX, ARIZONA 85029 EVALUATION SUBJECT: NATURAL LIGHT TUBULAR AND EZ TUBULAR SKYLIGHTS Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2018 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report ESR-3681 Reissued January 2018 This report is subject to renewal January 2019. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 08 00 00 OPENINGS Section: 08 62 00 Unit Skylights REPORT HOLDER: NATURAL LIGHT ENERGY SYSTEMS 10821 NORTH 23 RD AVENUE PHOENIX, ARIZONA 85029 (602) 485-5984 www.nltubular.com EVALUATION SUBJECT: NATURAL LIGHT TUBULAR AND EZ TUBULAR SKYLIGHTS 1.0 EVALUATION SCOPE Compliance with the following codes: 2009 and 2006 International Building Code (IBC) 2009 and 2006 International Residential Code (IRC) Properties evaluated: Structural Air infiltration Water penetration resistance Durability 2.0 USES The Natural Light Tubular and EZ Tubular Skylights are plastic-glazed skylights complying with IBC Sections 2405 and 2610 and IRC Section R308.6. 3.0 DESCRIPTION 3.1 Tubular Skylights noted under Table 1: The tubular skylights noted in Table 1 are nonopenable dome-shaped skylights which consist of the following components: a plastic dome, a gasket, base (curb-mounted or self-flashed), and an light tube. The plastic domes are formed from minimum 0.177-inch-thick smooth and flat sheets of Optix Acrylic Sheet recognized in ICC-ES report ESR-2591. See Figures 1A and 1B for more information regarding the components used in the skylights. 3.2 EZ Tubular Skylights noted under Table 2: The EZ tubular skylights noted in Table 2 are plastic-domed glazed tubular skylights available in nominal diameters of 10 and 14 inches (254 and 356 mm). Each skylight consists of the following components: a clear plastic dome; a self-flashing curb; adjustable and extension reflective tubes; a ceiling package including trim ring, inner and diffuser lenses, diffuser ring, miscellaneous fasteners and washers; foam tapes; kerf mounted seals, and hole cutting templates. The EZ10ECL also has a dimmer unit packaged with the other components. The dome shape is a hemisphere for 10-inch (254-mm) dome lenses and is a truncated hemisphere with a flat top for 14-inch (356-mm) dome lenses. Table 2 lists the skylight models, flashing and dome materials, dome diameters, dome rises, and reflective tube descriptions. Figure 2 shows a typical version of the EZ skylight assembly. 3.2.1 Material: 3.2.1.1 Plastic Dome: The plastics are manufactured from resins as identified in the approved quality control documentation. The acrylic plastic dome has a CC2 classification. The polycarbonate plastic dome has a CC1 classification. The nominal thickness of the 10-inch-diameter (245 mm) dome lens is 0.114 inch (2.89 mm) and is 0.115 inch (2.92 mm) for 14-inch-diameter (356 mm) dome lens. 3.2.1.2 Self-Flashing Curb: The self-flashing curb is made from one of three types of materials: 0.125-inch-thick (3.2 mm) Polytrope TPP 518, 0.063-inch-thick (1.60 mm) 1100-0 spun, or formable available as 0.023- to 0.032-inch-thick (0.58 to 0.81 mm) 1100-0 or 0.028- to 0.037-inch-thick (0.72 to 0.95 mm) 3003-0. 3.2.1.3 Adjustable and Extension Reflective Tubes: The diameter of the reflective tube is 10 inches (254 mm) for EZ10 and 14 inches (356 mm) for EZ1. The reflective tubes are formed from AL 99.85 (European Standard) or AA (Aluminum Association) 1085 0.016 ± 0.0016-inch-thick (0.41±0.041 mm) alloy sheet laminated with Alanod Miro 4400YP reflective film on the interior surface. 3.2.1.4 Light Diffuser: The light diffuser consists of a tempered glass diffuser lens and two-glass inner lenses. The thickness of all glass diffuser lenses is 0.125-inch (3.20 mm). 3.2.1.5 Fire-Resistant Ring: The fire-resistant ring is an band used as protection for the glazing exposed edge (See Figure 3). The rings are required to be installed only where classified roof coverings are required by the applicable code. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2018 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 7

ESR-3681 Most Widely Accepted and Trusted Page 2 of 7 3.2.2 Dimmer Unit: The dimmer unit of the EZ10ECL model connects the 10-inch (254 mm) reflective tube to the light diffuser. 3.2.3 Fasteners: 3.2.3.1 Self-Flashing Curb Mounting: The fasteners supplied with the skylights and used to attach the self-flashing curb of the skylight to the roof sheathing are No. 8 by 2-inch-long (51 mm), 18-8 stainless steel sheet-metal screws with 0.045-inch-thick-by- 3 / 4-inchdiameter (1.14 mm by 19.1 mm) fender washers. 3.2.3.2 Dome: The fasteners supplied with the skylights and used to attach the dome to the self-flashing curb are No. 8 by 3 / 4-inch-long (19.1 mm) Phillips pan head 18-8 stainless steel screws with No. 8 by 3 / 8-inch-outsidediameter (9.53 mm) stainless steel washers. 3.2.3.3 Ceiling Ring: The fasteners supplied with the skylights and used to attach the ceiling ring to the ceiling are No. 6 by 1-inch-long (25.4 mm) wallboard screws. 3.2.4 Roof Sheathing: The roof sheathing must be minimum 1 / 2-inch-thick (12.7 mm) plywood or oriented strand board (OSB) panel sheathing complying with the applicable code. 4.0 INSTALLATION AND DESIGN 4.1 Installation of Skylights noted under Table 1: 4.1.1 General: Installation must be in accordance with the manufacturer s published installation instructions, this report, and Sections 2405 and 2610 of the IBC and Section R308.6 of the IRC, as applicable. Skylights must be installed on roofs with slopes between 0 degrees (0:12) and 75 degrees (45:12) from the horizontal. A mininum height of 4 inches (102 mm) between the plastic glazing and plane of the roof must be maintained. In the event of conflict between this report and the manufacturer s published installation instructions, this report governs. 4.1.2 Self-Flashing: The self-flashing skylights are mounted directly to the roof deck assembly. Compatible sealant must be applied on the mounting flange of the selfflashing unit and covered with the roof covering in such a manner as to ensure a watertight seal. See Figures 1A and 1B for more installation details. 4.1.3 Curb-Mounted: The curb-mounted skylights must be installed on a wood curb made of minimum 2-by lumber with a minimum 0.42 specific gravity. The wood curb and the attachment to the roof structure must be designed to resist the appropriate code-prescribed loads. The gap between the skylight frame and the wood curb must be fully shimmed. Flashing must comply with, and be installed in accordance with, IBC Section 1507 or IRC Section 905, as applicable. See Figures 1A and 1B for more installation details. 4.2 Installation of Skylights noted under Table 2: 4.2.1 General: The skylights must be installed in accordance with IBC Sections 2405 and 2610, or IRC Section R308.6, as applicable; this report; and the manufacturer s published installation instructions. Skylights must be installed on roofs with slopes between 14 degrees (3:12) and 75 degrees (45:12) from the horizontal. A mininum height of 4 inches (102 mm) between the plastic glazing and plane of the roof must be maintained. All EZ skylights are limited to where nonclassified roof coverings are permitted except when the fire-resistant ring and spun self-flashing curbs are installed. In the event of a conflict between this report and the manufacturer s published installation instructions, this report governs. The skylights are prepackaged with all components, fasteners, attachments, and installation instructions in the shipping carton, except for the sealant recommended by the skylight manufacturer to be installed between the skylight and roof sheathing. For the EZ10, a 12-inchdiameter (305 mm) hole must be cut in the roof sheathing and an 11-inch-diameter (279 mm) hole must be cut in the ceiling below the attic space. For the EZ14, the corresponding ceiling and sheathing hole diameters are 16 inches and 15 inches (406 mm and 381 mm), respectively. 4.2.2 Self-Flashing: The skylight self-flashing curb must be treated with the sealant recommended by the skylight manufacturer applied around the bottom surface of the flashing and then must be attached to the plywood or OSB roof sheathing with the fasteners described in Section 3.2.3.1. The number of fasteners required is given in Table 2. The skylight dome lens must be attached to the selfflashing curb with four of the fasteners described in Section 3.2.5.2. Silicone sealant must be applied to the screw heads after placement. The reflective tubes must be inserted into the skylight self-flashing curb at the roof and must be terminated at the ceiling into a ceiling ring installed with three or four No. 6 by 1-inch-long (25-mm) drywall screws. The skylight diffuser must then be twisted onto the ceiling ring. For installation of the dimmer unit of the EZ10ECL model, the lower end of the 10-inch (254 mm) reflective tube is put into the top surface of the dimmer unit and the two are snapped together. The light diffuser must then be twisted onto the lower surface of the dimmer unit. The fire-resistant ring slides on the dome lens and conceals the lower 1 / 2-inch (12.7 mm) of the dome lens. It protrudes 1 / 2-inch (12.7 mm) beyond the bottom edge of the dome. The ring is supported by a horizontal flange of the dome and is held down by the heads of four screws that retain the dome lens to the flashing. 4.3 Design: 4.3.1 Allowable Loads: The performance grade (PG) rating values are provided in Tables 1 and 3. 4.3.2 Air Infiltration: When tested at an air pressure differential of 1.57 psf (75 Pa), the skylights have an air leakage rate of less than 0.30 cfm/ft 2 (1.5 L/s*m 2 ). 5.0 CONDITIONS OF USE The Natural Light Tubular and EZ Tubular Skylights described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The manufacturer s installation instructions must be available at the jobsite during installation. 5.2 The use of the skylights as components of fireresistance-rated assemblies is outside the scope of this report. 5.3 The skylights in Table 1 are available with different diffusers attached to the bottom end of the light tube. These are outside the scope of this report. 5.4 The connection of the dimmer unit of the EZ10ECL model to the reflective tubes and light diffuser and the dimmer unit components are outside the scope of this report.

ESR-3681 Most Widely Accepted and Trusted Page 3 of 7 5.5 The skylights are assembled in Phoenix, Arizona, under a quality control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Plastic Glazed Skylights (AC16), dated April 2011 (editorially revised August 2013). 7.0 IDENTIFICATION The Natural Light Tubular and EZ Tubular Skylights come in packages bearing the manufacturer s name and address; the model number; the CC1 or CC2 plastic classification of the plastic glazing (dome); the thickness of plastic glazing material prior to thermoforming the dome; a warning label complying with Class 1, ANSI Standard Z35.1-1972, specifications for accident prevention signs; allowable loads; and the evaluation report number (ESR-3681). TABLE 1 DIMENSIONAL DETAILS AND PERFORMANCE GRADES FOR NATURAL LIGHT TUBULAR SKYLIGHTS 1 MODEL PRODUCT 2 CURB DIMENSIONS INSIDE WOOD (inches) DOME RISE (inches) PG POS 3 (psf) PG NEG 4 (psf) 21KPCCM 18KPCM 13KFPC 10KCMP 21KFP 18KFP 13KFP 21" Dia. Tubular Skylights with Curb- Mounted Flashing 18" Dia. Tubular Skylights with Curb- Mounted Flashing 13" Dia. Tubular Skylights with Curb- Mounted Flashing 10" Dia. Tubular Skylights with Curb- Mounted Flashing 21" Dia. Tubular Skylights with Self- Flashing 18" Dia. Tubular Skylights with Self- Flashing 13" Dia. Tubular Skylights with Self- Flashing 24.5 x 24.5 5 1 / 2 100 100 25.25 x 25.25 5 100 100 18.75 x 18.75 5 5 / 16 100 100 18.5 x 18.5 4 1 / 4 100 100-5 1 / 2 100 100-5 100 100-5 5 / 16 100 100 10KFP 10" Dia. Tubular Skylights with Self- Flashing For SI: 1 inch = 25.4 mm; 1 psf = 0.0479kN/m 2. - 4 1 / 4 100 100 1 Installation must comply with Section 4.0 and Figures 1A and 1B. 2 Screws must be capable of resisting the tabulated loads when installed in metal-to-metal connections and metal-to-wood connections. 3 PG POS = Performance grade rating of the skylight under positive (inward) design pressure. 4 PG NEG = Performance grade rating of the skylight under negative (outward) design pressure.

ESR-3681 Most Widely Accepted and Trusted Page 4 of 7 2 x WOOD CURB, FLASHING NOT SHOWN 4 4 PLANE OF THE ROOF PLANE OF THE ROOF A - 10", 13", 18", or 21" Diameter Plastic Dome attached during the manufacturing process to a 0.063-inch-thick frame B - 4 ea., 1 / 4" Dia. S.S. Self-Tapping Screws C - Black Nylon Horse Hair Gasket (self-adhesive backed) D - 0.08-inch-thick Aluminum Base E - 4 ea., #8 by 1 1 / 2" long S.S. Screws F - 8 ea., #8 by 1 1 / 2" long S.S. Screws G - 0.02-inch-thick Aluminum Light Pipe Tube A - 10", 13", 18", or 21" Diameter Plastic Dome attached during the manufacturing process to an 0.063 inch thick frame B - 4 ea., 1 / 4" Dia. S.S. Self-Tapping Screws C - Black Nylon Horse Hair Gasket (self-adhesive backed) D - 0.08 inch thick Aluminum Base E - 8 ea., #10 by 1 1 / 2 inch-long S.S. Screws F - 0.02 inch-thick Aluminum Light Pipe Tube FIGURE 1A CURB-MOUNTED FLASHING FOR MODELS 21KPCCM, 18KPCM, 13KFPC, & 10KCMP FIGURE 1B SELF-FLASHING FOR MODELS 21KFP, 18KFP, 13KFP, & 10KFP

ESR-3681 Most Widely Accepted and Trusted Page 5 of 7 MODEL FLASHING MATERIAL TABLE 2 EZ TUBULAR SKYLIGHTS DESCRIPTIVE INFORMATION DOME MATERIAL DOME NOMINAL DIAMETER (in.) EZ10SCAK Polyethylene Acrylic 10 5 EZ10SCANH EZ14SCANH Polyethylene Acrylic EZ10ECL Polyethylene Acrylic 10 5 EZ10PRO3 EZ14PRO3 EZ10SCG EZ14SCG EZ10PRO2 EZ14PRO2 EZ10SCMNH EZ14SCMNH EZ10PRO EZ14PRO EZ10SCPNH EZ14SCPNH Polyethylene Formable Spun black Spun Spun black Spun For SI: 1 inch = 25.4 mm. 1 For use with nonclassified roof coverings Polycarbonate Acrylic Acrylic Acrylic Polycarbonate Polycarbonate DOME RISE (in.) REFLECTIVE TUBE DESCRIPTION 20 inches straight 15 inches adjustable bottom 10 5 25 inches adjustable top 14 6 25 inches adjustable bottom 25 inches adjustable top 25 inches adjustable bottom 10 5 15 inches adjustable top 14 6 15 inches adjustable bottom 20 inches straight 10 5 25 inches adjustable top 14 6 25 inches adjustable bottom 10 5 15 inches adjustable top 14 6 15 inches adjustable bottom 10 5 25 inches adjustable top 14 6 25 inches adjustable bottom 10 5 15 inches adjustable top 14 6 15 inches adjustable bottom 10 5 25 inches adjustable top 14 6 25 inches adjustable bottom TABLE 3 SKYLIGHT PERFORMANCE GRADE, PG, ALLOWABLE LOADS, AND NUMBER OF NO. 8 BY 2-INCH-LONG SCREWS FOR ATTACHING SKYLIGHT TO ROOF DECK MODEL DOME NOMINAL DIAMETER (in.) NUMBER OF FLASHING-DECK SCREWS PG POS (psf) PG NEG (psf) EZ10SCAK 10 8 90 90 EZ10SCANH 10 8 90 90 EZ14SCANH 14 8 80 80 EZ10ECL 10 8 90 90 EZ10PRO3 10 8 90 90 EZ14PRO3 14 8 80 80 EZ10SCG 10 9 65 65 EZ14SCG 14 9 50 50 EZ10PRO2 10 9 90 90 EZ14PRO2 14 9 90 90 EZ10SCMNH 10 9 90 90 EZ14SCMNH 14 9 90 90 EZ10PRO 10 9 100 100 EZ14PRO 14 9 100 100 EZ10SCPNH 10 9 100 100 EZ14SCPNH 14 9 100 100 For SI: I inch = 25.4 mm, 1 psf = 0.0479 kn/m 2.

ESR-3681 Most Widely Accepted and Trusted Page 6 of 7 FIGURE 2 EZ TUBULAR SKYLIGHT ASSEMBLY (Dimmer unit not shown for the EZ10ECL)

ESR-3681 Most Widely Accepted and Trusted Page 7 of 7 10" Diameter EZ Skylight 4" Minimum Curb Height 14" Diameter EZ Skylight 4" Minimum Curb Height FIGURE 3 FIRE-RESISTANT RING INSTALLED ON EZ SKYLIGHTS WITH SPUN ALUMINUM CURB