IBExU Institut für Sicherheitstechnik GmbH

Similar documents
Low voltage asynchronous motors Motors for use in potentially explosive atmospheres

ATEX/IECEx Coil Manual Type 200 and 300 Series Coils for EH70 Series Solenoid Valves Issue , Released December 13, 2017

Instruction Manual. Ex-Time 40 / 50

IBExU Institut für Sicherheitstechnik GmbH An-Institut der Technischen Universität Bergakademie Freiberg

Physical Technical Testing Institute Ostrava-Radvanice. Type Examination Certificate

ToughPIX 2300XP Series INSTRUCTIONS FOR SAFE OPERATION

AC centrifugal fan with housing (small flange)

AC centrifugal fan - RadiCal

AC axial fan. sickled blades (S series)

Unused flameproof threads for cable glands have to be closed with certified plugs.

CERTIFICATE OF COMPLIANCE

AC centrifugal fan. forward-curved, dual-intake with housing (without flange)

AC axial fan. sickled blades (S series) with guard grille for full nozzle

AC axial fan. sickled blades (S series) with full square nozzle

RadiPac EC centrifugal fans. New dimensions in efficiency: sizes 630 1,000

EXAMINATION CERTIFICATE

AC axial fan. Limited partnership Headquarters Mulfingen County court Stuttgart HRA

AC centrifugal fan. backward curved

AC axial fan. blades with special design (K series) with guard grille for full nozzle

AC centrifugal fan. forward curved, dual inlet with housing (without flange)

Operating Instructions

Ex m Solenoid Operator Type 0519

SITRANS P measuring instruments for pressure


AC axial fan. straight blades (A series) with full round nozzle

International approvals.

AC centrifugal fan. forward curved, dual inlet with housing (flange)

Control and Terminal Box Type A21-**-*****

AC axial fan. sickled blades (S series), single inlet Wall ring with guard grille

AC centrifugal fan. backward curved

AC axial fan. sickled blades (S series) Wall ring with guard grille

AC axial fan. sickled blades (S series)

Operating Instruction Inline Detonation Flame Arrester

A good connection. International approvals.

INDUSTRY PROCESS AND AUTOMATION SOLUTIONS. Technical Bulletin

AC centrifugal fan. forward-curved, single-intake with housing (flange)

AC centrifugal fan. forward curved, dual inlet with housing (flange)

Explosion-protected surface-mounting Thermostat ATH-Ex Series

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

Solenoid Operator 0513 / 1213

K Series 3 Way Direct Acting Balanced Poppet Solenoid Valve

AC centrifugal module - RadiCal

AC axial fan. sickled blades (S series) with guard grille for full nozzle

ABB MEASUREMENT & ANALYTICS DATA SHEET. TEIP11 I/P signal converter for standard signals

Type Electronic Limit Switch

Explosion Proof Equipment General Overview*

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PUA574 / PUA579(x)

Safety Instructions Proline Promass 300

Operating Instructions

TIP-200S-20 & TIP-200S-Ex-d-20 Power unit with electrohydraulic-acting spring-return rotary actuator (Normal & Explosion Proof Type)

INSTRUCTION MANUAL (ATEX / IECEx)

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Solenoid Operator 0516 / 1216

Zone 1 Linear Range - Installation Guide

Small centrifugal fans made of plastic

IECEx Certificate of Conformity

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Apparatus which gives off arcs or sparks can be integrated in distributions at low cost using flameproof enclosures. Built-in electrical components

Data Sheet DS/NGB-EN Rev. B. Multi barriers. Measurement made easy. Fieldbus barrier for PROFIBUS PA for FOUNDATION Fieldbus-H1

Modern Explosion Protection

ABB MEASUREMENT & ANALYTICS DATA SHEET. Series and Katharometer power supply units

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

Explosion and flame-proof single phase electric motors

Terminal Boxes in Stainless Steel SLS**.T

ATEX HAZARDOUS-AREA RATED CONTAINER HEATERS AND CONTROLLER PRODUCT LAUNCH BOOK

Volumeter. RMG Meßtechnik GmbH. Publication No E

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Explosion and flame-proof cast iron electric motors

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Reg No: 1999/027771/07 ACCREDITED AND APPROVED TEST LABORATORY IN TERMS OF ARP 0108: REGULATORY REQUIREMENTS FOR EXPLOSION PROTECTED APPARATUS

Series 3730 Electropneumatic Positioner Type

Centrifugal fan with highly efficient EC drive motor

Leading the way in hazardous areas Features EATON

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

Volute Casing Centrifugal Pumps PN 16 for heat-transfer liquids Heat-transfer oil up to 350 C Hot water up to183 C

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Resistance Thermometers Model TR602, for Flat Surfaces Model TR603, for Pipe Surfaces

(Text with EEA relevance)

Guide for installers. METTLER TOLEDO MultiRange Explosionsproof weighing system with the ID3sTx weighing terminal.

Operating Instructions Installation Information. METTLER TOLEDO MultiRange Weighing Platforms PFA574 / PFA575(x) / PFA579(x)

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Explosion proof electric motor For Fuel dispensing application. Main characteristic

Process resistance thermometer Model TR12-B, for additional thermowell Model TR12-M, basis module

PHOENIX CONTACT - 01/2008

COMMISSION REGULATION (EC)

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Category II 1 G only applies to the Constructional Variants shown in table 15.2 of annex 1.

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Solenoid coils VACF Type codes

JUMO dtrans p20 DELTA

ANKERSMID Temperature controller ATC 510/520/525 for wall-mounting. Application

Floodlight Range Installation Guide

DVGW Prüflaboratorium Gas DBI Gastechnologisches Institut ggmbh FREIBERG

PAB Atex-certified centrifugal pumps

Hermetical Standard Chemical Pump of PTFE / PFA with permanent magnet synchronous motor ISO 2858 / DIN EN 22858

Capanivo Series CN 4000

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

IECEx Certificate of Conformity

INSTRUCTION MANUAL (ATEX / IECEx)

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Transcription:

[1] EC-TYPE EXAMINATION CERTIICATE according to Directive 94/9/EC, Annex 111 [2] Equipment and Protective Systems intended for use in Potentially Explosive Atmospheres, Directive 94/9/EC [3] EC-Type Examination Certificate Number: [4] Equipment: Radial an type K3G***-****-9* and K3G***-****-X* [5] Manufacturer: ebm-papst Mulfingen GmbH & Co. KG [6] Address: Bachmühle 2 74673 Mulfingen GERMANY [7] The design of the equipment mentioned under [4] and any acceptable variations thereto are specified in the annex to this EC-Type Examination Certificate. [8] IBExU Institut für Sicherheitstechnik GmbH, Notified Body number 0637 in accordance with article 9 of the Directive 94/9/EC of the European Parliament and the Council of 23 March 1994, certifies that the equipment mentioned under [4] has been found to comply with the Essential Health and Safety Requirements relating to the design and construction of equipment intended for use in potentially explosive atmospheres given in Annex II to the Directive. The test results are recorded in the test report I B-14-3-094 of 26 May 2015. [9] Compliance with the Essential Health and Safety Requirements has been assured by compliance with EN 60079-0:2012+A11:2013, EN 60079-1:2007, EN 60079-7:2007 and EN 60079-11:2012 as weil as EN 50495:2010 and in dependence to EN 14986:2007. [1 0] lf the sign "X" is placed after the certificate number, it indicates that the equipment is subject to special conditions for safe use specified under [17] in the annex to this EC-Type Examination Certificate. [11] This EC-Type Examination Certificate relates only to the design and construction of the specified equipment. lf applicable, further requirements of this Directive apply to the manufacture and supply of this equipment. [12] The marking of the equipment mentioned under [4] shall include the following: e II 2G Ex d e ib 118 T3 G b -40 oc or -25 oc Ta +50 oc or +55 oc - Siegei (Kenn-Nr. 0637) Certificates may only be duplicated completely and unchanged. ln case of dispute, the German text shall prevail. Annex Page 1 of 2

[13] Annex [14] to the EC-TYPE EXAMINATION CERTIICATE [15] Description of the component The Radial an type K3G***-****-9* and K3G***-****-X* serves for conveying of gaseaus media and is preferential built in climatic box devices (AHU) because of its cube construction. lt consists of the explosion proof motor type M3G150-**-9*, M3G150-I**-9* or M3G150-NA**-9* and the impeller. The motor as external-rotor motor is designed with direct temperature control and consists of the Ex-e motor compartment, the Ex-d electronic compartment and the Ex-e terminal compartment. The electronic compartment houses the control unit, the electronics for functional safety as weil as the intrinsically safe supply for the sensors. The motor is cooled by the conveying medium. Technical data: 55 mm up to 120 mm max. 3.2 kw - Air flow: max. 20,000 m3/h - Static back pressure: max. 1,500 Pa 50/60 Hz - Nominal speed: max. 2,850 rpm - Mode of operation: 81 - Property class Ex-d screws: 10.9 - Degree of protection: Motor compartment IP 44 according to EN 60034-5 Terminal compartment IP 66 according to EN 60529 Electronics compartment IP 54 according to EN 60529 The rated values of the individual motor and impeller designs are specified in the Continuation Sheets to this EC-Type Examination Certificate. [16] Test report The test results are recorded in the test report IB-14-3-094 of 26 May 2015. The test and information documents are part of the test report and listed there. Summary of the test results The Radial an type K3G***-****-9* and K3G***-****-X* fulfils the requirements of explosion protection for Equipment Group II, Category 2G, type of protection flameproof enclosure "d", increased safety "e" and intrinsic safety "ib" for explosive atmospheres up to temperature class T3. [17] Special conditions for safe use - Repairs of the flameproof joints must be made in compliance with the constructive specifications provided by the manufacturer. Repairs must not be made on the basis of values specified in table 1 of EN 60079-1. - The screwed cable glands may be used only for fixed installation. During installation, an appropriate strain relief has to be ensured. - When replacing cable glands, please note that they must be suitable for a continuous operating temperature from -40 oc to +80 C. - With ambient temperatures below -20 C, the connection cables must be suitable for such operating temperature. [18] Essential Health and Safety Requirements Confirmed by compliance with standards (see [9]). 0 Page 2 of 2

Continuation Sheet 03 to the EC-TYPE EXAMINATION CERTIICATE Radial an type K3G500-AP25-9* and K3G500-AP25-X* On the basis of the test report 18-14-3-094/1 of 26 May 2015 the following specifications result: M3G 150-25-9* 380 Vup to 440 V 50/60 Hz 1,780 rpm 2.9 7 kw 4.5 A 500 150 mm 55 mm 8, 155 m3/h at 800 Pa 12,830 m3/h at 0 Pa 1,170 Pa IBExU 14ATEX1122 X. ae."... Seal (ID no. 0637) ln case of dispute, the German text shall prevail. Continuation Sheet 03

Continuation Sheet 04 to the EC-TYPE EXAMINATION CERTIICATE Radial an type K3G560-AP23-9* and K3G560-AP23-X* On the basis of the test report IB-14-3-094/ 1 of 26 May 2015 the following specifications result: M3G150-I23-9* 1,500 rpm 2.94 kw 4.5 A 560 160 mm 85 mm 9,280 m3/h at 700 Pa 14,545 m3/h at 0 Pa 1,030 Pa IBExU 14ATEX1122 X. reiberg, 26 May 2015 r Seal (ID no. 0637) ln case of dispute, the German text shall prevail. Continuation Sheet 04

Continuation Sheet 01 to the EC-TYPE EXAMINATION CERTIICATE Radial an type K3G400-AQ23-9* and K3G400-AQ23-X* On the basis of the test report IB-14-3-094/1 of 26 May 2015 the following specifications result: - Temperature limiter: M3G 150-23-9* 2,550 rpm 3. 10 kw 4. 7 A 400 125 mm 55 mm 6,085 m3/h at 1,100 Pa 9,390 m3/h at 0 Pa 1,500 Pa. (10 no. 0637) ln case of dispute, the German text shall prevail. Continuation Sheet 01

Continuation Sheet 02 to the EC-TYPE EXAMINATION CERTIICATE Radial an type K3G450-AQ24-9* and K3G450-AQ24-X* On the basis of the test report IB-14-3-094/1 of 26 May 2015 the following specifications result: Power input: M3G150-24-9* 2,040 rpm 2. 95 kw 4.5 A 450 140 mm 55 mm 6, 755 m3/h at 950 Pa 10,955 m3/h at 0 Pa 1,200 Pa IBExU 14ATEX1122 X. IBExU Institut für Sicherheitstechnik GmbH uchsmühlenweg 7-09599 reiberg, GERMANY +49 (0) 3731 3805-0 - +49 (0) 3731 23650 Authorised for certifications -Explosion protection- 0 7;... ln case of dispute, the German text shall prevail. Continuation Sheet 02

Continuation Sheet 05 to the EC-TYPE EXAMINATION CERTIICATE Radial an type K3G630-AP01-9* and K3G630-AP01-X* On the basis of the test report 18-14-3-094/1 of 26 May 2015 the following specifications result: - Nominal voltage range: M3G150-NA01-9* 1,130 rpm 2. 97 kw 4.6 A 630 224 mm 120 mm 11,540 m3/h at 600 Pa 18,240 m3/h at 0 Pa 730 Pa. IBExU Institut für Sicherheitstechnik GmbH uchsmühlenweg 7-09599 reiberg, GERM N:"(. ;,-.->, +49 (0) 3731 3805-0 - +49 (0) 3731 23650 /<:;<:::_;._-,C/IJ<J>. Authorised for certifications -Explosion protection- (,;(. \' ' ' r \ <P ;. -:-...-mr:ij {o-::>,. l 0 \I ' -.: ;nsutu' '. "f. ; _;;; Sic\:cr\H lcs- -:.. tecllnll'- ;;; G n1bh,.,,, '\. A-:---:- :?' Seal (ID no. 0637) and seal are not valid. in case of dispute, the German text shall prevail. Continuation Sheet 05