International Journal Of Global Innovations -Vol.2, Issue.I Paper Id: SP-V2-I1-048 ISSN Online:

Similar documents
Design and Implementation of an 11-Level Inverter with FACTS Capability for Distributed Energy Systems

International Journal of Advanced Research in Electrical, Electronics and Instrumentation Engineering. (An ISO 3297: 2007 Certified Organization)

[Patil, 7(2) April-June 2017] ISSN: Impact Factor: 4.015

A Single-Phase D-Statcom Five Level Inverter for Wind Applications

A Novel DC-DC Converter Based Integration of Renewable Energy Sources for Residential Micro Grid Applications

IJREE - International Journal of Research in Electrical Engineering ISSN:

Control Application of PV Solar Farm as PV- STATCOM for Reactive Power Compensation during Day and Night in a Transmission Network

Implementation of Bidirectional DC-DC converter for Power Management in Hybrid Energy Sources

Model Predictive Control of Back-to-Back Converter in PMSG Based Wind Energy System

INVESTIGATION AND PERFORMANCE ANALYSIS OF MULTI INPUT CONVERTER FOR THREE PHASE NON CONVENTIONAL ENERGY SOURCES FOR A THREE PHASE INDUCTION MOTOR

An Improved Efficiency of Integrated Inverter / Converter for Dual Mode EV/HEV Application

A.Arun 1, M.Porkodi 2 1 PG student, 2 Associate Professor. Department of Electrical Engineering, Sona College of Technology, Salem, India

Fuzzy based STATCOM Controller for Grid connected wind Farms with Fixed Speed Induction Generators

Wind Power Plants with VSC Based STATCOM in PSCAD/EMTDC Environment

INSTALLATION OF CAPACITOR BANK IN 132/11 KV SUBSTATION FOR PARING DOWN OF LOAD CURRENT

Dynamic Behaviour of Asynchronous Generator In Stand-Alone Mode Under Load Perturbation Using MATLAB/SIMULINK

COMPARISON OF PID AND FUZZY CONTROLLED DUAL INVERTER-BASED SUPER CAPACITOR FOR WIND ENERGY CONVERSION SYSTEMS

Multi-Port DC-DC Converter for Grid Integration of Photo Voltaic Systems through Storage Systems with High Step-Up Ratio

Control Scheme for Grid Connected WECS Using SEIG

PERFORMANCE AND ENHANCEMENT OF Z-SOURCE INVERTER FED BLDC MOTOR USING SLIDING MODE OBSERVER

Design and Implementation of Non-Isolated Three- Port DC/DC Converter for Stand-Alone Renewable Power System Applications

Design and Modelling of Induction Generator Wind power Systems by using MATLAB/SIMULINK

Simulation of real and reactive power flow Assessment with UPFC connected to a Single/double transmission line

Modeling and Simulation of Micro Grid System Based on Renewable Power Generation Units by using Seven Level Multilevel Converter

Power Flow Simulation of a 6-Bus Wind Connected System and Voltage Stability Analysis by Using STATCOM

DUAL BRIDGE RECTIFIER FOR PMSG VARIABLE SPEED WIND ENERGY CONVERSION SYSTEMS

Research Paper MULTIPLE INPUT BIDIRECTIONAL DC-DC CONVERTER Gomathi.S 1, Ragavendiran T.A. S 2

POWER TRANSMISSION OF LOW FREQUENCY WIND FIRMS

Comparative Analysis of Integrating WECS with PMSG and DFIG Models connected to Power Grid Pertaining to Different Faults

Wind-Turbine Asynchronous Generator Synchronous Condenser with Excitation in Isolated Network

Development and Analysis of Bidirectional Converter for Electric Vehicle Application

A Grid-Connected Dual Voltage Source Inverter with Power Quality Improvement Features Abstract

ANFIS CONTROL OF ENERGY CONTROL CENTER FOR DISTRIBUTED WIND AND SOLAR GENERATORS USING MULTI-AGENT SYSTEM

Simulation of Fully-Directional Universal DC- DC Converter for Electric Vehicle Applications

APPLICATION OF BOOST INVERTER FOR GRID CONNECTED FUEL CELL BASED POWER GENERATION

Performance of Low Power Wind-Driven Wound Rotor Induction Generators using Matlab


Behaviour of battery energy storage system with PV

Simulation Modeling and Control of Hybrid Ac/Dc Microgrid

Reactive Power Sharing Droop Control Strategy for DG Units in an Islanded Microgrid

Design of a Three Phase Multi-Level Inverter with Facts Capability for Distributed Energy

Reactive Power Compensation at Load Side Using Electric Spring

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 02, 2016 ISSN (online):

Design of Control Secheme and Performance Improvement for Multilevel Dc Link Inverter Fed PMBLDC Motor Drive

Research on Transient Stability of Large Scale Onshore Wind Power Transmission via LCC HVDC

Design and Implementation of Reactive Power with Multi Mode Control for Solar Photovoltaic Inverter in Low Voltage Distribution System

ELECTRICAL POWER SYSTEMS 2016 PROJECTS

A Grid Connected Dual Voltage Source Inverter with Improvement Power Quality Features

POWER ELECTRONICS & DRIVES

MODELING OF A MICROTURBINE WITH PMSM GENERATOR USING MATRIX CONVERTER TECHNIQUE FOR GRID INTERCONNECTION SYSTEM

SENSORLESS CONTROL OF BLDC MOTOR USING BACKEMF BASED DETECTION METHOD

1. RENEWABLE ENERGY I.SOLAR ENERGY PROJECT TITLES WE CAN ALSO IMPLEMENT YOUR OWN CONCEPT/IDEA

Power Management with Solar PV in Grid-connected and Stand-alone Modes

STUDY ON MAXIMUM POWER EXTRACTION CONTROL FOR PMSG BASED WIND ENERGY CONVERSION SYSTEM

Increasing the Battery Life of the PMSG Wind Turbine by Improving Performance of the Hybrid Energy Storage System

ENHANCEMENT OF ROTOR ANGLE STABILITY OF POWER SYSTEM BY CONTROLLING RSC OF DFIG

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Dual power flow Interface for EV, HEV, and PHEV Applications

I.INTRODUCTION. INDEX TERMS Energy management, grid control, grid operation,hybrid microgrid, PV system, wind power generation.

Energy Management System Control for a Hybrid Non-conventional Energy Sources using Hysteresis Switching Algorithm

FUZZY BASED CONTROL OF PV SOLAR FARM AS PV- STATCOM FOR REACTIVE POWER COMPENSATION DURING DAY AND NIGHT

`POWER QUALITY IMPROVEMENT FOR GRID CONNECTED WIND ENERGY SYSTEM USING STATCOM - CONTROL SCHEME

BIDIRECTIONAL DC-DC CONVERTER FOR INTEGRATION OF BATTERY ENERGY STORAGE SYSTEM WITH DC GRID

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET)

LOAD SHARING WITH PARALLEL INVERTERS FOR INDUCTION MOTOR DRIVE APPLICATION

EMS of Electric Vehicles using LQG Optimal Control

Inverter with MPPT and Suppressed Leakage Current

Combined Input Voltage and Slip Power Control of low power Wind-Driven WoundRotor Induction Generators

Low-Frequency AC Transmission for Offshore Wind Power

Development of Novel Connection Control Method for Small Scale Solar - Wind Hybrid Power Plant

Implementation of Bidirectional DC/AC and DC/DC Converters for Automotive Applications

Enhancement of Power Quality in Transmission Line Using Flexible Ac Transmission System

Analysis and Design of Improved Isolated Bidirectional Fullbridge DC-DC Converter for Hybrid Electric Vehicle

New York Science Journal 2017;10(3)

Using energy storage for modeling a stand-alone wind turbine system

China. Fig. 1 Chain SVG Electrical Diagram

An energy Storage using Cascaded Multilevel Inverters by PMSM with Autonomous Power Regernarative Control System

ADVANCED POWER CONTROL TECHNIQUES FOR HYBRID WIND-POWER GENERATION SYSTEM USED IN STANDALONE APPLICATION

Soft Switching of Two Quadrant Forward Boost and Reverse Buck DC- DC Converters Sarath Chandran P C 1

Benefits of HVDC and FACTS Devices Applied in Power Systems

To Increase System Efficiency for Portable Electronics Devices with DC-DC Converter

Design of Active and Reactive Power Control of Grid Tied Photovoltaics

Dynamic Modelling of Hybrid System for Efficient Power Transfer under Different Condition

APPLICATION OF STATCOM FOR STABILITY ENHANCEMENT OF FSIG BASED GRID CONNECTED WIND FARM

A Novel Hybrid PV/Wind/Battery based Generation System for Grid Integration

International Journal of Advance Engineering and Research Development. Automatic Power Factor Correction in EHV System

International Journal of Scientific & Engineering Research, Volume 7, Issue 6, June ISSN

Enhancing the Voltage Profile in Distribution System with 40GW of Solar PV rooftop in Indian grid by 2022: A review

Modeling and Simulation of Firing Circuit using Cosine Control System

A Novel GUI Modeled Fuzzy Logic Controller for a Solar Powered Energy Utilization Scheme

Power Electronics Projects

Bidirectional Intelligent Semiconductor Transformer

Power Electronics & Drives [Simulink, Hardware-Open & Closed Loop]

Fuzzy Logic Control Based MIMO DC-DC Boost Converter for Electric Vehicle Application Ans Jose 1 Absal Nabi 2 Jubin Eldho Paul 3

International Journal of Advance Research in Engineering, Science & Technology

Intelligent UPS System for Smart Grid to Achieve the Sustainable Energy

A NOVEL MULTIPHASE BIDIRECTIONAL FLY-BACK CONVERTER TOPOLOGY IS APPLIED TO INDUCTION MOTOR DRIVE

Targeted Application of STATCOM Technology in the Distribution Zone

VECTOR CONTROL AND DIRECT POWER CONTROL METHODS OF DFIG UNDER DISTORTED GRID VOLTAGE CONDITIONS

Hybrid Energy Powered Water Pumping System

Transcription:

Multilevel Inverter Analysis and Modeling in Distribution System with FACTS Capability #1 B. PRIYANKA - M.TECH (PE Student), #2 D. SUDHEEKAR - Asst Professor, Dept of EEE HASVITA INSTITUTE OF MANAGEMENT AND TECHNOLOGY, HYDERABAD, T.S., INDIA. Abstract: This paper presents the design of a multi-level inverter with Flexible AC transmission systems (FACTS) capability for small to medium size (10 20kW) permanent-magnet wind applications using modular multi-level converter (MMC) topology. The aim of the paper is to design a new type of inverter with Distribution static synchronous compensator (D-STATCOM) option to provide utilities with more control on active and reactive power transfer of distribution lines. The proposed inverter is placed between the renewable energy source, specifically a wind turbine, and the distribution grid in order to fix the power factor (PF) of the grid at a target value, regardless of wind speed, by regulating active and reactive power required by the grid. The D-STATCOM inverter is capable of controlling active and reactive power by controlling the phase angle ( ) and modulation index (m), respectively. The unique contribution of the proposed work is to combine the two concepts of inverter and D-STATCOM using a voltage source converter (VSC) multi-level topology in a single unit without additional cost. Simulations of the proposed inverter, with 11 levels, have been conducted in MATLAB/Simulink. The main function of the proposed inverter is to transfer the active power to the grid as well as keeping the powerfactor (PF) of the local power lines constant at a target PF regardless of the incoming active power from the wind turbine. KEYWORDS: Modular multilevel converter (MMC), multi-level inverter (MLI), wind energy inverter (WEI). I.INTRODUCTION The main role of power electronics in distribution systems are greatly increased recently. The power electronic devices are usually used to convert the non conventional forms of energy to the suitable energy for power grids, in terms of voltage (v) and frequency (f). In permanent magnet(pm) wind applications, a back-to-back converter is normally utilized to connect the generator to the grid. A rectifier (AC-DC) is equipped with a maximum power point tracker (MPPT),converts the output power of the wind turbine to a dc power. The dc power is then converted to the desired ac power for power lines using an inverter and a transformer. With recent developments in wind energy, utilizing smarter wind energy inverters (WEIs) has become an important issue. There is a lot of singlephase lines in the United States [2], which power small farms or remote houses. Such customers have the potential to produce their required energy using as mall-to-medium-size wind turbine (10-20kw). Increasing the number ofs mall-to-medium wind turbines are will make several troubles for local utilities such as harmonics or power factor (PF)issues. II.LITERATURE SURVEY Tremendous growth is occurred in the integration of distributed energy systems to the power systems utilizing FACTS technology. A majority of FACTS applications for a renewable energy sources are introduced over the past decade. The unique contribution of the current work is the combination of an inverter and a D-STATCOM (Distribution static synchronous compensator) for renewable energy sources in single-phase systems, using a new multi-level topology. Several key factors are to be considered throughout all stages of the work: 1) cost-effectiveness, 2) efficiency, and 3) compatibility with IEEE standards. In this project, a new single-phase inverter with D-STATCOM capability, using a new multi-level topology calle das modular multi-level converter (MMC), is introduced. The proposed inverter is designed for grid-connected wind turbines in the small- to medium sized (10kW-20kW) range. This new inverter regulates DC link voltage as well as active and reactive power injected to the grid through the distribution transformer in order to set the grid PF at a target value established by the user (utility). The proposed system provides high dynamic performance and power quality for power transmitted between the renewable energy source and the distribution grid. Paper Available @ ijgis.com JULY/2015 Page 220

III. EXISTING SYSTEM A high PF is generally desirable in a power system to decrease the power losses and improve voltage regulation at the load. It is often desirable to adjust the PF of a system to near1.0. When reactive elements are supply or absorb reactive powernear the load, the apparent power is reduced. In other words, the current drawn by the load is reduced, which decreases the power losses. Therefore, the voltage regulation is improved if the reactive power compensation is performed near large loads. Normally, utilities have to use capacitor banks to compensate the PF issues, which will increase the total cost of the system. IV.PROPOSED METHOD The modern ways of controlling the PF of these power lines are to use small distribution static synchronous compensators (D-STATCOMs). The D-STATCOMs are normally placed in parallel with the distributed generation (DG) systems as well as the power systems to operate as a source or sink of reactive power to increase the power quality issues of the power lines. By using regular STATCOMs for small-to-medium-size single-phase wind applications does not make the economic sense and increase the total cost of the system significantly. The proposed D-STATCOM inverter in this paper is equipped with ad-statcom option to regulate the reactive power of the local distribution lines and can be placed between the wind turbine and the power grid, same as a regular WEI without any additional cost. The function of the proposed inverter is not only to convert dc power coming from dc link to a suitable ac power for the main grid, but also to fix the power factor( PF) of the local grid at a target PF by injecting enough reactive power to the power grid. Fig. 2 shows the complete configuration of the proposed inverter. The dc link of the inverter is connected to the wind turbine through a rectifier using MPPT and its output terminal is connected to the utility grid through a series-connected second-order filter and a distribution transformer. The different modulation methods are such as sinusoidal pulse width modulation (PWM), selective harmonic elimination, optimized stepped waveform technique, and space vector modulation technique were discussed and compared [3]-[6]. Among all multilevel topologies, the cascaded H-bridge multilevel converter is very well known for STATCOM applications for Paper Available @ ijgis.com JULY/2015 Page 221

several reasons. The main reason is that it is simple to obtain a high number of levels, which can help to connect STATCOM directly to medium voltage grids.the modular multilevel converter (MMC) was introduced in the early 2000s [7]. This topology consisting of several half-bridge (HB) sub modules (SMs) per each phase, which are connected in series. An n-level single phase MMC consists of a series connection of 2(n 1) basic SMs and two buffer inductors. Fig.3 shows the proposed controller system. Proposed system having two modes of operation: A When the wind is blowing and active power is coming from the wind turbine: the inverter + D-STATCOM mode. In this mode, the device is working as a regular inverter to transfer active power from the renewable energy source to the grid as well as working as a normal D-STATCOM to regulate the reactive power of the grid in order to control the PF of the grid and 2) when wind speed is zero or too low to generate active power: the D-STATCOM mode. In this case, the inverter is acting only as a source of reactive power to control the PF of the grid, as a D-STATCOM. This option eliminates the use of additional capacitor banks or external STATCOMs to regulate the PF of the distribution feeder lines.the relation between the target reactive power and the target PF is, The second function of the controller systems is to keep the capacitors voltages balanced. In order to do this, a carrier based pulse width modulation (CPWM) method is used. The third function of the controller system is the PWM generation block. In this block, based on the desired modulation index, power angle, voltages of the capacitors, direction of the current flowing through the switches and the controller generates the PWM signals in order to meet all the system requirements. V. SIMULATION AND RESULTS The design of an 11-level MMC inverter was carried out in MATLAB/Simulink. The simulation is 20 s long and contains severe ramping and de-ramping of the wind turbine. Simulation of the proposed 11-level D-STATCOM inverter is shown in below. The inverter function is transferring active power from the wind turbine to the distribution grid as well as compensating the PF of the local distribution grid at the target PF of 0.90. Table 1 shows parameter values used for the simulation. Paper Available @ ijgis.com JULY/2015 Page 222

Fig:4 Simulation diagram In the 11-level simulation, discrete intervals are used as the amplitudes of the current controlled current sources. However, the output active power of the wind turbine differs because the DC link voltage is different in this case (2000 V in the 11-level model). Therefore, before t=19 s, the output the active power of the wind turbine is zero, representing wind speed is zero or too low to produce active power. After t=19 s, the power provided by the wind turbine ramps up to approximately 15 kw in four seconds and then ramps down to zero in seven seconds, followed by no wind power production for two seconds. Fig 5: 11-level inverter Paper Available @ ijgis.com JULY/2015 Page 223

VI.CONCLUSION In this paper, the concept of a new multilevel inverter with FACTS capability for small-to-mid-size wind installations is presented. The proposed system demonstrates the application of a new inverter with FACTS capability in a single unit without any additional cost. Replacing the traditional renewable energy inverters with the proposed inverter will eliminate the need of any external STATCOM devices to regulate the PF of the grid.clearly, depending on the size of the compensation, multiple inverters may be needed to reach the desired PF. The simulation results for an 11-level inverter are presented in MATLAB/Simulink. REFERENCES [1] Pedram Sotoodeh, Ruth Douglas Miller, Design and implementation of an 11-level inverter with FACTS capability I distribution system IEEE journal of emerging and selected topics in power electronics, vol. 2, no.pp.87-96,march 2014. [2] S. A. Rahman, R. K. Varma, and W. H. Litzenberger, Bibliography of FACTS applications for grid integration of wind and PV solar powersystems: 1995 2010 IEEE working group report, in Proc. IEEE Power Energy Soc. General Meeting, pp. 1 17Jul. 2011, [3] F. Z. Peng, J. S. Lai, J. W. McKeever, and J. VanCoevering, A multilevel voltage-source inverter with separate DC sources for static VArgeneration, IEEE Trans. Ind. Appl., vol. 32, no. 5, pp. 1130 1138, Oct. 1996. [4]L. M. Tolbert and F. Z. Peng, Multilevel converters as a utility interface for renewable energy systems, in Proc. IEEE Power Eng. Soc. SummerMeeting, vol. 2.pp. 1271 1274. Jul. 2000. [5] S. Kouro, M. Malinowski, K. Gopakumar, J. Pou, L. G. Franquelo, B. Wu, et al., Recent advances and industrial applications of multilevelconverters, IEEE Trans. Ind. Electron., vol. 57, no. 8, pp. 2553 2580, Aug. 2010. [6] C. Tareila, P. Sotoodeh, and R. D. Miller, Design and control of a single-phase D-STATCOM inverter for wind application, in Proc.PEMWA, pp. 1 5.Jul. 2012. [7] B. Gemmell, J. Dorn, D. Retzmann, and D. Soerangr, Prospects of multilevel VSC technologies for power transmission, in Proc. IEEETransmiss. Distrib. Conf. Exposit., pp. 1 16.Apr. 2008. Paper Available @ ijgis.com JULY/2015 Page 224