Lightweight and sealed

Similar documents
Fire & Smoke Resistant Connector

UTS In-line receptacle

38999 Series III Composite Connectors

Integrated Backshell Fire Proof Connector

Miniature Break Away Release Connector

38999 All In One! Series III Integrated Backshell

Now Available in Black Zinc Nickel

8STA/8TA Series. Compact Circular Connectors Derived from MIL-DTL & JN1003. Connection Technologies

ARINC 600 SERIES. Rack & Panel Rectangular Connectors. Selector Guide

UTS SERIES. Waterproof Plastic Connectors. IP68 and IP69K

MIL-DTL 38999Series III Aluminium Series

Compact Low Profile Connectors with High Hermeticity Performance

A Complete Miniature Range Threaded, Break Away, Bayonet

Luminus Series Amphenol Pcd

8N45S NC Series Non-safety classified connectors for EPR reactors

Ethernet 100 Mbps Quadrax

Class 1E LOCA Cabled Connectors

K2 Qualified Connectors for EPR Reactor

8D Series D38999 Stainless Steel Series

8D Series D38999 Aluminum Series

SRC SERIES. Signal Connectors with bayonet locking system. Derived from VG95234 & in accordance with the NF F standard

for Quadrax and ELIO 8

Amphenol-Tuchel Electronics 44 Series

Monobloc Insulator Rectangular Connectors

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

KVBS Reverse bayonet connectors for railway applications

REP Series. Environmentally-Sealed Rectangular Plastic Connectors

Amphenol Amphenol PCD Shenzhen HVBI High Voltage with Inter-Lock

MIL-C 26482G Series II

π network filter insertion loss - attenuation (db)

Amphenol 348 Series High Density Connectors

D-SUB Series. Electrical Max current rating per contact : 7.5 A. Insulation resistance : 5000 MΩ Contact resistance : 10 mω

AMPHENOL PCD SHENZHEN ASGTC. Ruggedized Connector Series for Rail & Mass Transit and Other Harsh Environmental Applications.

Excel Mate Mono High Voltage with Inter-Lock

DATA-CON-X : SEALED USB TYPE A & B CONNECTORS

nterconnect compatibility new SEALED CONNECTORS harsh environment dual seals for harsh environments ergonomic locking tab for easier mating

UTS Series Dynamic IP68/69K UV Resistant UL/IEC Compliant

CMC/CPP/CMB SERIES. Power & signal connectors with screw locking system. Human photo. Can be environmental/ documentaty style or portrait of engineer.

PEGASUS SERIES. Amphenol Pcd. Amphenol Pcd

8T Series. MIL-DTL Series II

Directory chapter 03 DIN Power (to 15 A) Types H, H 3, MH , MH Technical characteristics type H

HV HV Series Connector and cable assembly

DTP Series : Contacts (Open Barrel) Type Barrel Type GA Size

9316 series Underwater applications Explosion proof Hermetically sealed

Amphenol Amphenol PCD Shenzhen Excel Mate High Voltage Safety Lock

UTS Series. Dynamic IP68/69K UV Resistant UL/IEC Compliant

AS85049/88/89/90 SERIES

µcom-10gb + Harsh Environment 10Gb Ethernet Micro Connectors

MIL-DTL-38999Series III Composite Series

Electrical Dielectric withstanding Altitude Service At ground 1500 Vrms m 600 Vrms m 400 Vrms m 200 Vrms

Cannon Trident Connectors

Rail Product Selection Guide. Proven rail expertise. Global capabilities.

Circular Connectors. Contents. Introduction Specifications Cable Connectors Panel Connectors Accessories

D X X - XX - XX - X X

Electrical Test voltage (Vrms) Service sea level at m M I II

DT04 08P + W8P

MILITARY MOTORSPORT INDUSTRIAL PRODUCT RANGE

HERMETIC. Hermetic Connectors. High Performance Sealing Solutions

Electrical Voltage rating Test Voltage (Vrms) service rating sea level at 21000m M N I II

4000 Series Buccaneer

EN3716 SAE AS81659 ARINC

8D Series D38999 Composite Series

Featuring Radsok Technology. eco mate rm. Rugged Metal Shielded Connectors RELIABLE SIGNAL AND POWER SOLUTIONS

Amphenol SCE2/Terrapin Series

SCE. Snatch Connector Electrical Series

Modular Bayonet connectors: a flexible solution for data and signals transmission in railways harsh environment.

DT Family. Contents. DT Family Overview 18 DTV Series 28. Part Numbering System 18 DTMH Series 29. Dimensions 19 DTMN Series 30

RockStar HighPower. Contents. RockStar HighPower Introduction C.2 C.1

8D Series D38999 Composite Series

Cannon Trident Connector System

Topside / Shipboard Environmental Connectors

EPIC. Pin & Sleeve Connectors PIN & SLEEVE CONNECTORS

EPIC CIRCON M23 Series

CL-3/1297 CGL INDUSTRIAL POWER INPUT CONNECTORS UP TO 700 V

General characteristics and technical data Series MCS

Features and Application

FISCHER FREEDOM TM SERIES

Han-Power Energy Bus Components

Modular Bayonet connectors: a flexible solution for data and signals transmission in railways harsh environment.

POLAMCO HIGH POWER CONNECTORS STYLE

Amphenol. Bombardier Transportation Design Guide for Amphenol GT Series Reverse Bayonet Coupling Connectors

Metal limit switches are made of zinc alloy and have a degree of protection of IP67 and NEMA Type 4, 4X.

HD30 & HDP20 Series. Contents. Mounting 88. Overview. Dimensions 80. How To Instructions Part Numbering System 81. Configurations 82-83

Circular Connectors Conforming to JIS C 5432

Crimpmate Range pitch 5.00

Tajimi Electronics Co

2mm Pitch, Positive Lock, Wire-to-Board Connector (UL, C-UL Listed)

UTG. Plastic connector with metal coupling system

DEUTSCH HDJ Series Filter Connectors MIL-DTL SERIES I.5

Connectors and interconnect systems for severe environments

K CHAPTER FREEDOM TM SERIES EASY MATING EASY CLEANING EASY INTEGRATION FISCHER KEY FEATURES

HBB CONNECTOR SERIES. Engineering Superior Solutions. September 2015 Smiths Connectors. smithsconnectors.com

6LGH High Voltage Connectors

WILDCAT CONNECTORS

Amphenol. RFM Series.

Technical Data, 4-way. Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc. ISO 15170) Materials List

Molded & Mechanical Military Connectors (MIL-C-5015)

8LT SERIES. Aerospace & Military Bayonet Connectors. MIL-DTL Series I

Deutsch Connectors. Catalogue Number #2014TDC.

HyperGrip - Push/Pull Plastic Circular Connectors

Transcription:

ightweight and sealed The solution for indoor applications using 1 standard AWG16 contact Secure for indoor applications Water jet & underwater proof Flame retardant material IP68/IP69K Easy to handle Ergonomic design Wire sealing High contact density Grommet option Up to 23 contacts #16

SOURIAU on the railway market The SOURIAU solution offers a wide range of connector layouts providing a simplified process from purchasing to harnessing: 1 type of contact to order, to manage, to stock, to crimp for a wide range of connectors. SOURIAU s standardisation policy is the best compromise between technology and cost. SOURIAU connectors ensure the continuity of the network with railway qualified connectors integrating new technologies: copper contacts, Quadrax and fibre optics to transfer high speed Ethernet and other data protocols. SOURIAU, along with its customers is committed to the research of energy efficiency and sustainability. The use of lightweight materials, fiber optics and high contact density contribute to the weight reduction of train equipments and help railway operators to save energy. 2

Technical features Housing: thermoplastic _> 500 hours salt spray resistant Bayonet coupling Mating cycles: 250 mating cycles Vibration & shocks: sinusoïdal vibrations per EI 60512-4 from 1 to 2000Hz Max current per contact: 15Amps Insulation resistance: 5000MΩ Withstanding voltage: 2550Vac following FF 61030 Flammability rating: U94-VO, I2F3/I3F2 following FF 16-101 / 16-102 Sealing: IP68/69K with suitable accessories Operating temperature: -40 / +105 40/100/21 per FF 61-030 Rated insulation voltage * according to E 50-124-1: "Railway applications - Insulation coordination". The rated insulation voltage * is given per layout according to: overvoltage level: - OV3 means a 2500V rated impulse voltage pollution degree of the environment: - P2 means only non conductive pollution occurs except that occasionally a temporary conductivity caused by condensation is to be expected - P3 means conductive pollution occurs or dry non conductive pollution occurs which becomes conductive due to condensation which is to be expected creepage and clearance, depending on the insert and the type of the contacts used: for layouts that use AWG16 contacts we recommend to use shorter female contacts (R16M23GE7K) to reach a higher operating voltage level. * is not the working voltage. * has to be chosen according to the voltage of the power supply U n. *efinition of rated insulation voltage (E 50-124-1): r.m.s. withstand voltage value assigned by the manufacturer to the equipment or to a part of it, characterizing the specified (long-term) withstand capability of its insulation. OTE: The rated insulation voltage is not necessarily equal to the-rated voltage of equipment which is primarily related to functional performance. Example for a battery supply system: Power supply Voltage U n Battery supply system (V) Extract from E50-124-1 Appendix Minimum rated insulation voltage of the electrical circuit on: Rolling stock (kv) Fixed installations (kv) 24 & 36 0.05 0.05 48 & 72 0.1 0.1 110 & 120 0.15 0.15 For more details please refer to UTS catalog. Ordering information UTS UTS UTS UTS 0 1 6 7 12 12 12 12 S P P S Shell style: 0: Square flange receptacle 1: In line receptacle 6: able plug 7: Jam nut receptacle Shell size: 10 12 16 18 ontact layout: see page 4 ontact type: P: Pin S: Socket Orientation: o letter: standard version W,X,Y,Z: different orientations (consult factory) 3

ontact layouts Size 10 10-3 2 1 10-3P 3Ø1.6 (#16) 300V - OV3 - P2 220V - OV3 - P3 10-4 A B 10-04P 4Ø1.6 (#16) 150V - OV3 - P2 150V - OV3 - P3 102W2 1 4 2 300V - OV3 - P2 3 220V - OV3 - P3 2Ø2.4 (#12) 2Ø1.0 (#20) Size 12 12-4 12-8 1 12-4P 3 2 4Ø1.6 (#16) 300V - OV3 - P2 260V - OV3 - P3 F E G H A 12-8P B 8Ø1.6 (#16) 150V - OV3 - P2 100V - OV3 - P3 Size 2G1-7 -12 300V - OV3 - P2 220V - OV3 - P3 5 4 6 1-7P 2 3 300V - OV3 - P2 260V - OV3 - P3 A J B H M K G F E -12P 150V - OV3 - P2 80V - OV3 - P3 3Ø3.6 (#8) 7Ø1.6 (#16) 12Ø1.6 (#16) Size 18 18-23 A B P R S Y M X Z T 18-23P W V U K J H E F G 23Ø1.6 (#16) 150V - OV3 - P2 80V - OV3 - P3 4

Receptacle Square flange receptacle B Ø3.2 Front view Shell size B UTS0104P 10 15 23.8 UTS0124P 12 19 UTS0128P 31.7 11.35 2.3 26.2 UTS012P 22.2 28.6 UTS01823P 18 28.5 2.5 33.3 For female contacts Shell size B UTS0104S 10 15 23.8 UTS0128S 12 19 2.3 26.2 31.7 11.35 UTS012S 22.2 28.6 UTS01823S 18 28.5 2.5 33.3 ote : all dimensions are in mm 5

Jam nut receptacle 1 2 3 UTS7103P UTS7104P UTS7102W2P UTS7124P UTS7127P UTS72G1P UTS77P UTS712P Shell size 1 2 3 B onnector type Termination 10 33.9 UTS71823P 18 28.5 19.3 41.3 36.6.9 27 22.2 12 19 31.8 27 35.75 33.9 22.2 34.9 30.2 UTS7G104P 10 41.9 27 22.2 UTS7G128P 12 40.7 19 31.8 27 UTS7G7P UTS7G12P 43 22.2 34.9 30.2 UTS7GJ104P 10 70.5.9 27 22.2 UTS7GJ128P 12 74 19 31.8 27 UTS7GJ7P UTS7GJ12P UTS7103S UTS7104S UTS7102W2S UTS7124S UTS7127S UTS72G1S UTS77S UTS712S 80.5 22.2 34.9 30.2 iscrete wire sealing UTS standard Shell size 1 2 3 B onnector type 10.9 27 22.2 12 19 31.8 27 33.9 - - 19.3 22.2 34.9 30.2 UTS71823S 18 28.5 41.3 36.6 UTS standard ut and grommet able gland and grommet ote : all dimensions are in mm 6

Plug Plug with cable gland For female contacts Shell size Termination UTS6J103P UTS6J103S UTS6J104P UTS6J104S 10 63.2 26.7 UTS6J102W2P UTS6J102W2S UTS6J124P UTS6J124S UTS6J128P UTS6J128S 12 66.7 30.2 UTS6J2G1P UTS6J2G1S UTS6J7P UTS6J7S 71.5 35.1 UTS6J12P UTS6J12S UTS6J1823P UTS6J1823S 18 81.3 42 able gland Plug with grommet Only available for female contacts Shell size Termination UTS6G104S 10 32 26.2 UTS6G128S 12 32.3 29.7 UTS6G7S UTS6G12S 32 34.6 UTS6GJ104S 10 61.5 26.2 UTS6GJ128S 12 64.5 29.7 UTS6GJ7S UTS6GJ12S 70 34.6 ut & grommet able gland & grommet ote : all dimensions are in mm 7

In line receptacle UTS1J103P UTS1J104P UTS1J102W2P UTS1J124P UTS1J127P UTS1J2G1P UTS1J7P UTS1J12P In line receptacle with accessories Shell size 1 2 ØB onnector type Termination For further information, click here www.railway-connectors.com Or contact us click here contactindustry@souriau.com 8 ØB 10 70.9 26.7 12 74 19 30.1 78.5 22.2 35.1 UTS1J1823P 18 89 28.5 42 UTS1G104P 10 40.9.9 26.2 UTS1G128P 12 40.9 19 29.7 UTS1G7P UTS1G12P 43 22.2 34.6 UTS1GJ104P 10 70.7.9 26.2 UTS1GJ128P 12 74.5 19 29.7 UTS1GJ7P UTS1GJ12P For female contacts UTS1J103S UTS1J104S UTS1J102W2S UTS1J124S UTS1J127S UTS1J2G1S UTS1J7S UTS1J12S 80.5 22.2 34.6 ØB 1 2 iscrete wire sealing UTS standard ut and grommet able gland and grommet Shell size 1 2 ØB onnector type Termination 10 70.9 26.7 12 74 19 30.1-78.5 22.2 35.1 UTS1J1823S 18 89 28.5 42 UTS standard ote : all dimensions are in mm WIUTSRWO02E opyright SOURIAU 2010 - All information in this document presents only general particulars and shall not form part of any contract. All rights reserved to SOURIAU for changes without prior notification or public announcement. Any duplication is prohibited, unless approved in writing.