General Specifications

Similar documents
Model UT601: OPERATING MANUAL

Model UT602/603: OPERATING MANUAL

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

OPERATING INSTRUCTIONS

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

Digital Multimeter User's Manual

Dawson DDM190D. Digital Multimeter User s Manual

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

UT108/109 Handheld Automotive Multi-Purpose Meters Operating Manual

operating manual DL7 101 DIGITAL THERMOMETER

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

True RMS Autoranging Multimeter

365 Detachable Jaw True-rms Clamp Meter

362 Clamp Meter. Users Manual

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

T2 Tester. Calibration Information. Introduction. Safety Information

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

Autoranging Multimeter

WENS30C Loop Calibrator

Autoranging Industrial Multimeter

Item ref: UK & UK MTB01 & MTB02 DIGITAL MULTITESTERS. User Manual

AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A

INSTRUCTION MANUAL DM5B Fax: (503)

i400s Calibration Information Introduction

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

Mini Multimeter with Non-Contact Voltage Detector (NCV)

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

323/324/325 Clamp Meter

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

373 Clamp Meter. Users Manual

TABLE OF CONTENTS 1. FEATURES SPECIFICATIONS... 1

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

USER MANUAL. Insulation Tester + DMM. Model MG320

Mini Multimeter with Non-Contact Voltage Detector (NCV)

5.2 PRE-OPERATION PROCEDURE WARRANTY

DT304. Digital Temperature Logger INSTRUCTION MANUAL

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

NGW & HGW SERIES CONTENTS OPERATION MANUAL CAUTIONS HIGH RESOLUTION MULTI-FUNCTION DIGITAL SCALE 1. INSTALLATION 2. SPECIFICATIONS

Dawson DAN100. Analog Multimeter User s Manual

302+/303 Clamp Meter. Users Manual

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

Users Manual. Phase Rotation Indicator

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

MODEL No: TA SAFETY INSTRUCTIONS 2. FEATURES. fig.1. Original Language Version

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

Safety design conforming to the following provisions

l The Battery Tester is designed for measuring the l AC four-terminal method to measure the internal

Volt/mA Calibrator. Manual

OPERATING INSTRUCTIONS

Calibration Manual. Detachable Jaw True-rms Clamp Meter

Users Manual. Airflow Meter

HD110C Heavy-Duty Digital Multimeter

PD-20 HIGH VOLTAGE PROBE INSTRUCTION MANUAL

TRIPLETT. Model 310 Type C Type 9. Test Equipment Depot Washington Street, Melrose, MA TestEquipmentDepot.

707Ex. Users Manual. ma Calibrator


99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Lumitester PD-30. Instruction Manual. Table of Contents

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

1.Safe testing IMPORTANT:

OPERATION AND MAINTENANCE

362 Clamp Meter. Users Manual

User's Guide. True RMS Multim eter. Extech 430

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

Temperature Probe, Battery (installed), Instruction Sheet, Quick Reference Card and Warranty Card.

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

Table of Contents Title Page No.

27 II/28 II. Digital Multimeters. Getting Started Manual. Specifications

POCKET-TACH 100 MONARCH INSTRUMENT Rev 1.4. Instruction Manual. Printed in the U.S.A. Monarch Instrument 2001 all rights reserved

41210S CIRCUIT BREAKER FINDER WITH GFCI Instrucciones de uso Detector de Interruptores con GFCI 41210S. Operating Instructions

Visit us at

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

Users Manual. MegOhmMeter

USER'S MANUAL. Standard-version BM810 & BM510 Series. X-version BM810X & BM510X Series. CF-version BM810CF & BM510CF Series

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

EGT MONITOR AND PROBE KIT BG FUEL SYSTEMS McDonald Road Dahlonega, GA (706) A Edition 03

OPERATING INSTRUCTION

Table of Contents. 1. The Statement Overview Instrument Familiarization Method of use General Specifications...

Safety design conforming to the following provisions

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC A

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

Digital/Analog Megohmmeter Model 1026

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

i3000s/i2000 Flex AC Current Probe

Automated Precision Weighing

Instruction Manual. Vibration Severity Meter VM12

BENCHTOP INSTRUMENT BENCH TYPE DIGITAL MULTIMETER DM-1140B OPERATION MANUAL V2.0

Digital/Analog Megohmmeter Model 1026 USER MANUAL

LAVOLTA DC REGULATED POWER SUPPLY BPS-305

Transcription:

General Specifications Maximum Voltage between any Terminals and Grounding: 1000V. Fused for Input Terminal: Model DMM8060/8061Glass fuse, 0.5A, 250V, fast type, 5x20mm. Fused for 10AInput Terminal: DMM8060/8061 Glass fuse, 10A, 250V, fast type, 5x20mm. Maximum Display: Digital: 3999 Measurement Speed: Updates 3 times/second. Temperature: Operating : 0 o C~40 o C (32 o F ~104 o F). Storage : -10 o C~50 o C (14 o F~122 o F). Relative Humidity: : 75% @ 0 o C - 30 o C; 50% @ 31 o C - 40 o C; Altitude: Operating: 2000 m. Storage : 10000 m. Battery Type: One piece of 9V (NEDA1604 or 6F22 or 006P). Battery Deficiency: Display Dimensions (HxWxL): 177 x 85 x 40 mm. Weight: Approximate 300g (battery included). Safety/Compliances: IEC61010 CAT.III 1000V, CAT.IV 600V overvoltage and double insulation standard. Certifications:, UL & CUL 26

Accuracy Specifications (1) Accuracy: (a% reading + b digits), guarantee for 1 year. Operating temperature: 23 o C 5 o C. Relative humidity: 75%. Temperature coefficient: 0.1 x (specified accuracy)/1 o C A. DC Voltage Range Resolution Accuracy 400mV 0.1mV (0.8%+3) 4V 40V 1mV 10mV (0.8%+1) 400V 100mV 1000V 1V (1%+3) Input impedance B. AC Voltage Range Resolution Accuracy 1000V DC 750V AC rms continuous. 4V 1mV 40V 10mV 1000V DC (1%+5) 750V AC rms 400V 100mV continuous. 750V 1V (1.2%+5) Input impedance 10M. Model DMM8060: displays effective value of sine wave (mean value response). Model DMM8061: displays true rms value. Frequency response 40Hz~400Hz. C. Resistance Range Resolution Accuracy Measure at 400 0.1 REL mode (1.2%+2) 4k 1 40k 10 (1%+2) 1000Vp 400k 100 4M 1k (1.2%+2) 40M 10k (1.5%+2) Open circuit voltage approximate 0.45V. 27

Accuracy Specifications (2) D Continuity Test Range Resolution Accuracy 400.0 0.1 Approximate 100 1000Vp Buzzer beeps continuously. Open circuit voltage approximate 0.45V. E. Diode Test Range Resolution Diode 1mV 1000Vp Open circuit voltage approximate 1.48V. Displays approximate forward voltage drop reading 0.5V~0.8V. F. Capacitance Range Resolution Accuracy Measure at REL mode (3%+10) (3%+5) 1000Vp (4%+5) G. Frequency & Duty Cycle Range Resolution Accuracy 10Hz~10MHz (0.1%+3) 0.1%~99.9% 0.01% 1000Vp 10Hz~10MHz Range: 1MHz: 300mV rms input sensitivity 30V rms; 1MHz: 600mV rms input sensitivity 30V rms. 0.1%~99.9%: Reading is only for reference purpose. 28

Accuracy Specifications (3) H.Temperature (Model DMM8060/8061) : Glass fuse 0.5A, 250V, fast type, 5x20mm. I. DC Current 400 A 0.1 A 0.5A, 250V, fast type Glass fuse, 5x20 mm. 10A, 250V, fast type Glass fuse, 5x20 mm. 4A & 10A Range: For continuous measurement 10 seconds and interval not less than 15 minutes. 29

Accuracy Specifications (4) J. AC Current 400 A 0.1 A 0.5A, 250V, fast type Glass fuse, 5x20 mm. 10A, 250V, fast type Glass fuse, 5x20 mm. Model DMM8060 : displays effective value of sine wave (mean value response). Model DMM8061: displays true rms value. 4A & 10A Range: For continuous measurement 10 seconds and interval not less than 15 minutes. 30

MAINTENANCE This section provides basic maintenance information including battery and fuse replacement instruction. Warning Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration, performance test, and service information. To avoid electrical shock or damage to the Meter, do not get water inside the case. A. General Service Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. To clean the terminals with cotton bar with detergent, as dirt or moisture in the terminals can affect readings. Turn off the power of the Meter when it is not in use and take out the battery when not using for a long time. Take out the battery when it is using for a long time. Do not use or store the Meter in a place of humidity, high temperature, explosive, inflammable and strong magnetic field. B. Testing the Fuses Warning To avoid electrical shock or personal injury, remove the test leads and any input signals before replacing the battery or fuse. To prevent damage or injury, install ONLY replacement fuses with identical amperage, voltage, and speed ratings. To test the fuse: 1. Model DMM8060: Set the rotary switch to and pressblue button to select. 2. Plug a test lead into the terminalhzv and touch the probe to the10a terminal. 31

If the Meter beeps, the fuse is good. If the display shows, replace the fuse and test again. If the display shows any other value, have the Meter serviced and contact your dealer immediately. If the Meter does not work while the fuse is all right, send it to your dealer for repair. C. Replacing the Battery (see figure 12) (figure 12) Warning To avoid false readings, which could lead to possible electric shock or personal injury, replace the battery as soon as the battery indicator appears. Make sure the test leads are disconnected from the circuit being tested before opening the case bottom. To replace the battery: 1. Press the POWER to turn the Meter off and remove all connections from the terminals. 2. Remove the screw from the battery compartment, and separate the battery compartment from the case bottom. 3. Remove the battery from the battery compartment. 4. Replace the battery with a new 9V battery (NEDA1604, 6F22 or 006P) 5. Rejoin the case bottom and battery compartment, and reinstall the screw. 32

D. Replacing the Fuses(see figure 13) (figure 13) Warning To avoid electrical shock or arc blast, or personal injury or damage to the Meter, use specified fuses ONLY in accordance with the following procedure. To replace the Meter s fuse: 1. Press the POWER to turn the Meter off and remove all connections from the terminals. 2. Remove the screw from the battery compartment, and separate the battery compartment from the case bottom. 3. Remove the 2 rubber feet and 2 screws from the case bottom, and separate the case top from the case bottom. 4. Remove the fuse by gently prying one end loose, then take out the fuse from its bracket. 5. Install ONLY replacement fuses with the identical type and specification as follows and make sure the fuse is fixed firmly in the bracket. Fuse 1: Glass fuse 0.5A, 250V, fast type, 5x20mm. Fuse 2: Glass fuse 10A, 250V, fast type, 5x20mm. 33

6. Rejoin the battery compartment and the case top, and reinstall the screw. 7. Rejoin the case bottom and case top, and reinstall the 2 screws and 2 rubber feet. Replacement of the fuses is seldom required. Burning of a fuse always results from improper operation. 34

RS232C Serial Port (Model DMM8061) A.RS232C Port Cable The Meter D-sub D-sub 9 Pin Female Computer D-sub 25 Pin Female Pin Name B.Setting of RS232C Serial Ports Default of RS232C serial port for communication is set as: Baud Rate 2400 Start bit 1 (always 0) Stop bit 1 (always 1) Data bits 7 Parity Odd C.System Requirements for Installing the DMM8061 Interface Program To usedmm8061 Interface Program, you need the following hardware and software: An IBM PC or equivalent computer with 80486 or higher processor and 640 x 480 pixel or better monitor. Microsoft Windows 95 or above. At least 8MB of RAM. At least 8MB free space in hard drive. Can access to a local or a network CD-ROM. A free serial port. A mouse or other pointing device supported by Windows. Please refer to the included CD-ROM Installation Guide & Computer Interface Software for installing and operating instructions of the DMM8061 Interface Program. ~ END ~ This operating manual is subject to change without notice. 35