Application Specification.062 Diameter Pin and Socket Contacts and Housings 21 MAR 11 Rev E

Application Specification Pin&3Pin Miniature waterproof connector 28July2016 REV: C

JUL 14 Rev B

Standard Timer Connectors

3.18-mm [.125-in.] POWERBAND* Contacts

POWER TRIPLE LOCK* Connector System

FASTON* 110 Series. Receptacle With F Crimp Insulation Support Barrel. Wire Barrel. Insulation Support Barrel. Figure 1

Power Double Lock Connector System

Series 110 MK III, Series 187 MK II and MK III, Series 250 MK II, MK III, and RAST 5 & 7

Coaxial Snap-Lock Connectors

Economy Power (EP) 2.5 Contacts; Plug and Receptacle Housings; and Vertical and Right-Angle Headers

FAKRA-Compliant SMB Gen-4 Connector System

APPLICATION SPECIFICATION

Commercial MATE-N-LOK* Pin and Socket Contacts

FAKRA-Comliant SMB 50-Ohm Inline Connectors 27 JUN 11 Rev E

Instruction Sheet Crimping Die Assemblies , , and

FASTON* High Temperature Tab Terminals

Application Specification

PLASTI-GRIP* Terminals and Splices

11DIA SQUIB CONNECTOR COMPACT TYPE

AMPLIMITE* HDP- 20 and Economy

Position Cat6 Shielded. Modular Plug Connectors. Application Specification

Crimpmate Range pitch 5.00

AMP MCP Interconnection System AMP MCP 6.3/4.8K Contact System

Data sheet E-DAT Industry terminal rail TS35 + RJ45 coupler insert Cat.6 Class E A

FAKRA Automated In-Line Connector System

VAL-U-LOK* Series Headers, Connectors, and TPA Accessories

Quick Reference Guide AMP CT Connector Series

APPLICATION SPECIFICATION

PRODUCT SPECIFICATION STANDARD TIMER CONNECTOR, RAST 5mm, 2-12 POSITIONS

Assembly Instruction. EL OCHITO BLUE CONTACTS SuperSpeed USB TYPE I: PIN /SKT CABLE:

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

7.92mm Contact Pitch High-Current Connectors for Internal Power Supplies (UL, C-UL and TÜV Listed)

Assembly Instruction EL OCHITO WHITE CONTACTS 1000BASE-T/10GBASE-T TYPE I: PIN /SKT CABLE: S/FTP

2M Series Contacts and Tools

General characteristics and technical data Series MCS

20 HUBER+SUHNER RADOX SOLAR

1mm Contact Pitch, Board-to-Cable, Board-to-FPC, Board-to-Micro-coaxial Cable Connectors

HVP deg 1pos Plug&Header Connector Assy APPLICATION SPECIFICATION

HDD Insert Series. Application Specification Apr 30 th, 2017 Rev. A. Table of contents

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

AMP STACK III Modular connection system

Underground Bus Bar Distribution System 03 SEP 13 Rev B

Directory chapter 03 DIN Power (to 15 A) Types H, H 3, MH , MH Technical characteristics type H

HD Insert Series. Application Specification Apr 30 th, 2017 Rev. A. Table of contents

APPLICATION SPECIFICATION

- 1 - General ordering data Order No

AMPSEAL 16* Connector System 24 JUN 13 Rev C

Voice/Data/ Video Tools

7.92mm Contact Pitch High-Current Connectors for Internal Power Supplies (UL, C-UL and TÜV Listed)

MDual Power Connector

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

Sealed Sensor Connector (SSC) System

Universal MATE-N-LOK* Connectors

MMC RTX series EN3716

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

Data sheet. E-DAT Industry RJ45 field plug PROFINET. Illustrations P/N PI EAN Product specification. Page 1/

Data sheet E-DAT Industry patch cord V6 IP67 - RJ m

Data sheet Patch cord Cat.6 A AWG m black

JUL 17 Rev M

MAR 11 Rev H

Micro MATE N LOK* Connectors

Aug07 Rev A All Paragraphs Revised

Data sheet. E-DAT modul REG 1 port IP20 light gray. Illustrations P/N E EAN Product specification. Page 1/

Amphenol-Tuchel Electronics 44 Series

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6A, light gray

Data sheet E-DAT modul 24x8(8) 1RU patch panel Cat.6 A, stainless steel

Tooling Assistance Center

2. Use Extraction Tool (contact extraction tool). Insert releasing tip into the REAR of the. cavity between the spring and center wall of the

Datasheet. BL/SL 5.08 series BLF 5.08/02/180 SN OR BX

Installation Instructions K656CY, K656CH and K656I Deadbreak Receptacles

HBB power connector. Product description

AMPLIMITE.050 Series Cable Assemblies, Series III

Data sheet E-DAT modul Cat.6 A 8(8) jack, T568A

Data sheet Patch cord Cat.6 A AWG m gray

Product Specifications (for connectors) and (for headers), provides product performance requirements and test result information.

Installation Instructions

RA CONNECTOR IDC. 1Certified LR Features. Standards. Disconnectable Insulation displacement connectors for 1.27mm pitch ribbon cables. 2.

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Fine Pitch SMT Stacking Connectors (Parallel Board-to-Board) Stacking Height mm inch

Application Specification. 2P Mini Fuse Box. 2P Mini Fuse Box - GENERAL PARTS, NOT RESTRICTED - A New Release 30OCT2015 Kunal G Rajesh Koti

38568, 43177, and Long-Reach Chain Saws

PRODUCT SPECIFICATION

Data sheet E-DAT subway 9 port GB3 pearl white

1mm Pitch Cable-to-Board Connectors supporting LVDS signal

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

May08 Rev C

Cabling Instructions NOνA Project Written By: Dale Mudd September 21 st, 2010

Jun06 Rev D

Quick Reference Guide 1.5 mm AMP Mini CT Connector Series

Data sheet. E-DAT modul Cat.6A 8(8) jack, T568A. Illustrations P/N I EAN Product specification. Page 1/

Component Specification

Data sheet Connection line M12-RJ45 4-pole D-coded AWG m

Powermate Range pitch 7.00 Powermate Range pitch 7.00

CMC Hybrid Connectors Standard and Power Versions

Small-Sized, Low Profile 1.0mm Height, Wire-to-Board Connectors for Power Supply

Data sheet C6 A modul 24 port 180 M 1RU stainless steel

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

CMC Hybrid Connectors Standard and Power Versions

Transcription:

Application Specification 114-18040-1 Ø1,5mm System Rev G EC: EGA0-0875-04 1,5 mm Contact System DIRECTORY 1. Introduction...2 2. Referenced Documents 2.1 Product Numbers and Product Codes...3 2.2 Customer Drawing...4 2.3 Instructional Material...4 2.4 Specifications...4 3. Requirements 3.1 Wire...5 3.2 Crimped Contact...6 3.3 Mounting of the Pin after Redesing...8 3.4 Application of the extraction tool for the pin...8 Charts / Pictures Chart 1 Product oversight...3 Chart 2 Insulation lenght...5 Chart 3 Application data...6 Chart 4 AWG/ISO cross reference...9 Picture 1 Contact...2 Picture 2 Contact with single wire seal...2 Picture 3 Wire...5 Picture 4 Crimpwidth / -height...6 Picture 5 Referent gauge...7 Picture 6 Crimped contact...8 Tyco Electronics Corporation, Harrisburg, PA 17105 * Trademark Indicates change This specification is a controlled document. Copyright 2000 by Tyco Electronics Corporation. All rights reserved 1 of 9 ECOC EGA0

1. Introduction This specification covers the requirements for application of 1,5mm dia pin and socket contacts. These instructions are primarily for automatic application, but use can also be made of a handtool. Crimped Contact Orientationflag Pin Contact Pin Contact Locking Spring Socket Contact Barrel-to Receptacle Transition Area Insulation-to Wire Barrel Transition Area Insulation Barrel Housing (cross-section) Wire Barrel Cut-off Picture1 Contact with single wire seal Single seal Pin Contact Crimp for Single Wire Sealing Plug in direction ad housing Picture 2 Rev G 2 of 9

2. Referenced Documents 2.1 Product Numbers and Product Codes Contact Wiretype Wire Range / mm 2 Insulation Range / mm Part Number Strip Loose Piece Existing Types No. Handtool No. Single Wire Sealing Seal No. Cavity Plug No. FLR 0,2 0,4 1,15 1,6 - - Pin FLR 0,5 1,0 1,4 2,1 - - FLR >1 2,5 1,9 3,0 - - FLR 0,2 0,4 1,15 1,6 929 985 962 994-1; 2-878 480 734 285-1 - - Socket FLR 0,5 1,0 1,4 2,1 929 986 962 995-1; -4; 2-878 481 734 285-1 - - FLR >1 2,5 1,9 3,0 929 987 962 996-1; 2-878 482 734 285-2 - - Pin for Single Wire Sealing FLR 0,2 0,4 1,2 2,1 1703012 1703016-1; -4; 2-878 484 734 289-1 828 904 828 922 FLR 0,5 1,0 1,2 2,1 1703013 1703017-1; -2; -4; 2-878 485 734 289-1 828 904 828 922 FLR >1 2,5 2,2-3,0 1703014 1703018-1; -4; 2-878 486 539 679-2* 828 905 828 922 Socket FLR 0,2 0,4 1,2 2,1 929 988 962 997-1; -2; 2-878 484 734 289-1 828 904 828 922 for Single -1; -4; -7; FLR 0,5 1,0 1,2 2,1 929 989 962 998 2-878 485 734 289-1 828 904 828 922 1-0; Wire Sealing FLR >1 2,5 2,2 3,0 929 990 962 999-1; -4; 1-0 2-878 486 539 679-2* 828 905 828 922 *Die for ERGOCRIMP-Basis Handtool PN 539635-1 Chart 1 Notes : Application Specification for single wire sealing 114-18018; - extraction tool socket 518 082-1; spare tube 548 551-1; - extraction tool pin 3-1579007-7; spare tube 3-1579007-8 single wire sealing dash-no. : 1; cavity plug dash-no. 1; -2 Contact dash-no.: -1 CuNiSi pre tinned; -2 CuNiSi silver plated ; -3 CuNiSi gold plated; -4 CuFe2 pre tinned; -7 CuNiSi electroplated silver; -8 CuNiSi electroplated gold; 1-0 CuNi18Zn20 plain ; Not each dash variant exists for every Basenumber. Not existing could be checked. Minimum pitch : 5mm x 5mm (5mm x 4,4mm) for normal application and 5,7mm x 5,7mm for single-seal-system. ( ) = for displaced rows Rev G 3 of 9

2.2 Customer Drawing An AMP Customer Drawing is available for each part number assigned to this product line (see chart.1). In the event of a variance between this specification and the customer drawing, the customer drawing will take precedence. Crimp information shall be taken from the customer drawings. 2.3 Instructional Material IS 7424 AMP Instruction Sheet describes measurement of the crimp height. AI 8025 deals with the MQC crimp tool. CM 5128 includes information for the crimping machine. 2.4 Specifications AMP Spec. 108-18028 AMP Spec. 114-18022 AMP Spec. 114-18018 -Design Objective containing the requirements and performance of these contacts. -General instructions for the application of contacts with open barrel. -Application Specification for single wire sealing. Rev G 4 of 9

3 Requirements 3.1 Wire A. Wire Selection The crimping barrels of each contact are designed to receive stranded copper wire (Chart. 1). Other wires need the approval of the Engineering Department. Consult AMP for details. Only Single termination is permissible. B. Wire Preparation The wire must be stripped to the dimension shown in figure 3. Care must be exercised to prevent cutting or nicking of the wire strands. Care must also be taken, when handling wire during crimping to prevent cracking or breaking of the wire strands or the insulation. Part-No. Insulation Lenght Part-No. Insulation Lenght 1703012 4,5 ± 0,3mm 1703013 4,5 ± 0,3mm 1703014 5,0 ± 0,3mm 929 985 4,3 ± 0,3mm 929 988 4,5 ± 0,3mm 929 986 4,3 ± 0,3mm 929 989 4,5 ± 0,3mm 929 987 5,3 ± 0,3mm 929 990 5,0 ± 0,3mm Chart 2 Picture 3 Rev G 5 of 9

3.2 Crimped Contact A. Cut-off The cut-off must be visible after crimping. The maximum length is 0,5mm. Burrs resulting from shearing of the cut-offs may not exceed 0,08mm. Order number No. Crimpwidth CB / mm Wirecrimp Wire cross sectional / mm 2 Crimpheight CH / mm DISC Ltr. Insulationcrimp Crimpwidth / mm 929 985 2-878 480 1,58 F 0,35 1,11 A 2,30 O 929 986 2-878 481 2,03 F 929 987 2-878 482 2,54 F 1703012 929 988 1703013 929 989 1703014 929 990 0,5 1,27 C 0,75 1,36 B 1 1,45 A 1,25 1,6 D 1,5 1,67 C 2 1,82 B 2,5 1,97 A 2,54 O 3,30 O 2-878 484 1,58 F 0,35 1,11 A 3,93 O 2-878 485 2,03 F 2-878 486 2,54 F 0,5 1,27 C 0,75 1,36 B 1 1,45 A 1,5 1,67 C 2 1,82 B 2,5 1,97 A Chart 3 4,06 O 4,30 O Picture 4 Rev G 6 of 9

B. Wire Barrel The crimp form, crimp height and crimp width as well as the wire range can be taken from the customer drawing. The crimp extractions forces must meet the requirements of DIN IEC 352 part 2. The rear bellmouth is 0,4 ± 0,2mm for all wire ranges. A front bellmouth is permissible. The conductor ends must extend beyond the front of the wire barrel by 0,1mm min. / 1,0mm max. C. Insulation Barrel The requirements for the insulation grip effectiveness are laid down in DIN IEC 352 part 2. For processing apply the following difference to AMP Spec. 114-18018 and 114-18022: -The edgewise deviation of the longitudinal axis in the crimping area may not exceeded 2 in either direction. -The deviation of the longitudinal axis in the crimping area may not exceeded 2 in up and down direction. -The single seal may toppled max. 2 in up and down direction in the crimp. Picture 5 For compliance of these requirements, the gauge (PN 1241162) shown in picture 5 must be used. D. Contact Area Cantilever spring with locking spring and the contact body may not be twisted or damaged after crimping. Rev G 7 of 9

Crimped contact 114-18040-1 Wire insulation and strands must be visible in this area Closed Insulation Crimp Closed Wire Crimp (No visible wire strands) Conductor Location (0,1-1,0mm) Effective Crimp Length Rear Bellmouth Front Bellmouth Rear Cut-off (max. 0,5mm) Burr Allowance (max. 0,08mm) Picture 6 3.3 Mounting of the Pin after Redesign Related to the new design of the contact cavity, the pin gets a orientationflag, because of its three possible positions to lock in the cavity. While inserting, the correct orientation of the contact is easy to find by slightly turning in. 3.2 Application of the extraction tool for the pin The extraction tool is slitted now and has to be inserted oriented into the contact cavity. Rev G 8 of 9

AWG / ISO cross reference DIA 1,5mm Socket (basic part number) 929988 2-878484-2 DIA 1,5mm Pin (basic part number) 1703012 Wire size ISO 6722 Cross section Type USA SAE J1128 AWG Cable type Outer diameter (Insulation) Single Wire Seal 0,35mm² FLR 1,30-1,40mm 828904-1 2-878484-2 22 TXL 1,50-1,75mm 828904-1 929989 2-878485-2 929990 2-878486-2 1703013 2-878485-2 1703014 2-878486-2 0,50mm² FLR 1,58-1,70mm 828904-1 20 TXL 1,68-1,93mm 828904-1 0,75mm² FLR 1,78-1,90mm 828904-1 18 TXL 1,88-2,13mm 828904-1 1,00mm² FLR 1,98-2,10mm 828904-1 0,50mm² FLK 2,06-2,30mm 828905-1 20 GXL 2,06-2,41mm 828905-1 0,75mm² FLK 2,26-2,50mm 828905-1 18 GXL 2,18-2,54mm 828905-1 1,0mm² FLK 2,46-2,70mm 828905-1 16 TXL 2,16-2,41mm 828905-1 1,5mm² FLR 2,28-2,40mm 828905-1 2,0mm² FLR 2,66-2,80mm 828905-1 14 TXL 2,51-2,77mm 828905-1 2,5mm² FLR 2,86-3,00mm 828905-1 16 GXL 2,57-2,92mm 828905-1 1,5mm² FLK 2,76-3,00mm 828905-1 14 GXL 2,82-3,18mm 828905-1 2,5mm² FLK 3,32-3,60mm --- Chart 4 Rev G 9 of 9