WATER SPRAY NOZZLE DATA SHEET

Similar documents
MODEL: HV-AS & HV-BS TECHNICAL DATA : MAINTENANCE DESCRIPTION PRESSURE (3/4 NPT OPTIONAL)

Data Sheet High Velocity Water Spray Nozzle. Issue B. Rapidrop Global. Ref: SPTDHV/E TECHNICAL DATA MAINTENANCE DESCRIPTION

Data Sheet 11.2 Issue B

HIGH VELOCITY WATER SPRAY NOZZLE (BRASS)

Data Sheet 11.1 Issue A

TECHNICAL DATA SHEET. Medium Velocity Water Spray Nozzle. Page 1. Description. Technical and Environmental Specification. Installation & Maintenance

MEDIUM VELOCITY WATER SPRAY NOZZLE

Data Sheet Issue E

MEDIUM VELOCITY WATER SPRAY NOZZLE

DELUGE VALVE DATA SHEET

SPRAYTECS Series UP High Velocity Directional Spray Nozzles, Open, Non-Automatic. Suitable for Water Spray fixed systems.

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

MODELS F822 THRU F834

Directional Spray Nozzles, Open, with Strainers High Velocity General Description

GW THERMOCOOL NOZZLE STRUCTURAL STEEL PROTECTION

model E Spray nozzles vk810 - vk817

TECHNICAL DATA VK810 (65 ) VK811 (80 ) VK812 (95 ) VK813 (110 )

Type D3S PROTECTOSPRAY Directional Spray Nozzles, Open, Medium Velocity General Description. Technical Data. Page 1 of 6 AUGUST 2018 TFP804

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

SOLID CONE SPRAY NOZZLES TECHNICAL DATA

Type EA-1 PROTECTOSPRAY Directional Spray Nozzles, Automatic, Medium Velocity General Description

GW M5 WATER MIST NOZZLE K-5, LOW PRESSURE, NON-AUTOMATIC

Section E Fine Spray Nozzles

TECHNICAL DATA OBSOLETE

TECHNICAL DATA. Table Standard Materials

In-Line Balanced Pressure Proportioner (ILBP) Proportioning Devices Model KBP

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

FRAME STYLE SPRAY NOZZLES TECHNICAL DATA

Worldwide Contacts.

Hollow cone nozzles.

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

mirage standard and Qr concealed pendent sprinkler vk462 and hp sprinkler vk463 (K5.6)

Foam Maker Discharge Devices Model KLF

CNC DISTRIBUTION. ITEM NO Description Quantity

ANGLE VALVES 300LB. RATED OPTIONAL FINISHES: PB- Polished Brass RC- Rough Chrome Plated PC- Polished Chrome Plated U/L LISTED NY BSA/MEA APPROVED

TECHNICAL DATA. Viking Technical Data may be found on Style: 90 Degree Pattern (inlet to outlet)

TECHNICAL DATA 1-1/2 (dn40)

I-VICFLEX.AB7 VicFlex Sprinkler Fittings for Ceiling Suspension Systems STYLE AB7

TECHNICAL DATA. Q= C v P S

G1849 Eyewash, Deck Mounted, AutoFlow 90º Swing-Down

TECHNICAL DATA. Q= C v P S FLOW CONTROL VALVE MODEL J-2 HALAR COATED 1-1/2 & 2 (DN40 & DN50) 1. DESCRIPTION

FIRE SPRINKLER SYSTEM

Q= C v P S. Flow control valve Model j-2 Halar coated

Instructions for Installation, Operation, Care and Maintenance

Foam Ratio Controller Proportioning Devices Model KFP

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Price Book - Section 7 Nozzles and Sprinkler Accessories

Price Book - Section 7 Nozzles and Sprinkler Accessories

Installation & Design Maintenance for ILBP System

Hollow Cone Spray Nozzles Series

Portable Sealcoating Spray Systems

TECHNICAL DATA Code No. SFM-OH1 SFM-OH2 SFM-OH3 SFM-OH3S SFM-XHH-10 SFM-XHH-7.5 SFM-XLH

Nessie Water Mist Nozzles

Tank Sealcoating Spray Systems

DV-5a Automatic Water Control Valve Single Interlock Preaction Fire Protection Systems 1-1/2 Inch to 8 Inch (DN40 to DN200) General Description

TECHNICAL DATA. Q= C v P Cv = Flow Factor (GPM/1 PSI P)

DIKE AND SPILL PROTECTION

Eye/Face Washes. FF G1778 Eye/FaceFWash,FWallFMountedFAutoFlow F90 FSwing-Down FFG1778LH-L FFG1778LH-R G1778L G1778LH G1778 G1778R.

TUV India Private Ltd. APPROVED

Application & Reference Data Typical Specifications. Section 914 Vertical Turbine Fire Pump

007 Tank Monitor. WARNING Never use with gasoline or highly flammable liquids.

DEMA MODELS P203CTC.PI.1,.2,.3 INSTALLATION INSTRUCTIONS

ALARM CHECK VALVE 3", 4" & 6" MODEL H-1 FLANGE/FLANGE 3" & 4" MODEL H-2 GROOVE/GROOVE 3", 4" & 6" MODEL H-3 FLANGE/GROOVE

Section J Air Control Nozzles

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Automatic Roof Door Vents

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Full cone nozzles.

TECHNICAL DATA. Table Standard Materials

TECHNICAL DATA. Inlet Type Outlet Type OBSOLETE 6 (DN150)

CHEMICAL INJECTION PASSIVATING COATING STERILIZING FOGGING HUMIDIFYING MISTING COATING MOISTURIZING GAS COOLING LUBRICATING

Solenoid Operated Block Valves A2800 Series

Product Data Screwed Valve bodies

Back Check Valves A2885 & A2883 (LPG) A2882 (Refined Fuels)

Amerex Modular Dry Chemical Vehicle Fire Suppression System

Instructions for Installation, Operation, Care and Maintenance

Model VKFD28 Flexible Sprinkler Drops (LPCB Approved) Installation Manual. January 2016 Form No. F_ Rev 16.1

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

Technical Data. UL Listing is based on the following criteria:

B21 Series BASOTROL Gas Valve

Model 540 PRESSURE REGULATOR VALVE FOR ABOVE GROUND STORAGE TANKS WITH SUCTION TYPE ISLAND DISPENSERS

TECHNICAL DATA. Table Standard Materials

GRAFIK TM BF1356-XXX-200 PREMIA : T375 Thermostatic Shower System SPECIFICATIONS

DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Wet Pilot Actuation General Description

TECHNICAL DATA. Trimpac 244a. April 15, 2011

INLINE FOAM INDUCTOR HD FIRE PROTECT PVT. LTD. TECHNICAL DATA DESCRIPTION SPECIFICATION APPLICATION SYSTEM DESIGN DETAILS

Used for Safety Shower combination stations: SE-603 SE-616 SE-690 SE-693 SE-695 SE-697

Fire Protection Valves

Wet pipe low flow foam/water manifold system

TECHNICAL DATA. Trimpac 249a. September 16, 2013

Hollow Cone Nozzles. The H series nozzle option diverts flow at a right angle without an internal vane, thereby reducing the risk of blockage.

MAXIMUM FREE PASSAGE FULLJET SPRAY NOZZLES UNIQUE DESIGN MINIMIZES CLOGGING, PROVIDES SUPERIOR PERFORMANCE

Peerless Pump FIRE PUMPS. Horizontal Split-Case, Vertical Turbine, In-Line and End Suction. Sterling Fluid Systems (USA), Inc.

UltraJet Nozzle. AKRON BRASS COMPANY PH ( ) akronbrass.com

Ecco Fire Extinguishers

1/8" to 1/4" female conn. Flow rates of 1 gpm and greater at 40 psi (3.8 lpm and greater at 2.8 bar)

Table 1. Table 2. Table 3: Toxicology/Environmental FM-200 (UL/FM) 14A-07H SECTION 1 - INTRODUCTION. Agent Physical Properties FM-200


TECHNICAL DATA TRIMPAC MODEL B-4, B-4B & B-4S SINGLE INTERLOCK PREACTION SYSTEM WITH PNEUMATIC RELEASE

Transcription:

FIRE FIGHTING EQUIPMENT DATA SHEET WATER SPRAY NOZZLE DATA SHEET JOB NO. : RFQ. NO. : ISSUE : SHEET OF 01 CUSTOMER: ITEM NO. : 02 PROJECT : QUANTITY : 03 LOCATION : SERVICE : FIRE WATER SYSTEM 04 05 06 MODEL NO. CODE & STANDARDS HV-A WITHOUT STRAINER, HV-AS WITH STRAINER 07 APPROVALS UL LISTED FM APPROVED KFEIC OTHERS 08 CODE & STANDARDS NFPA BS KFPL OTHERS 09 OPERATING CONDITIONS 10 TEMPERATURE MIN. : ( ) OPER. : ( AMB ) DESIGN : ( 60 ) 11 PRESSURE MAXIMUM WORKING : ( 12.3 ) kg/cm² MIN. EFFECTIVE WORKING : ( 3.5 ~ 10.5 ) kg/cm² 12 FLUID HANDLED WATER AND / OR SEA WATER FOAM-WATER SOLUTION 13 INSTALLATION OUTDOOR AND / OR INDOOR 14 DESIGN FEATURES 15 TYPE HIGH VELOCITY MEDIUM VELOCITY 16 SIZE & CONNECTION 3/4" NPT MALE 3/4" BSPT MALE 17 SPRAY ANGEL AND 75 / K 22 80 / K 18 18 K-FACTOR 90 / K 32 100 / K 26 19 MATERIALS 20 HOUSING BRASS 21 SCROLL BRASS 22 ACCESSORIES 23 24 25 TEST & INSPECTION 26 DIMENSION INSPECTION WITNESS REVIEW MATERIAL INSPECTION WITNESS REVIEW 27 VISUAL INSPECTION WITNESS REVIEW PERFORMANCE TEST YES NO 28 FINISH UNIT WEIGHT 29 PAINTING N/A ( 0.2 ) Kg 30 COLOR NATURAL CHROME PLATED 31 32 33 34 35 36 37 38 39 40 41 42 43 44 REV DATE PRP'D CHK'D APP'D DESCRIPTION 45 0 2006-11-25 J. K. JEONG Y. K. AN S. M. LEE FOR STANDARDIZATION 46 47 48 49 1 2 3 4

HIGH VELOCITY WATER SPRAY NOZZLE TECHNICAL DATA : MODEL MAXIMUM WORKING PRESSURE EFFECTIVE WORKING PRESSURE END CONNECTION MATERIAL HV-A Without strainer HV-AS with strainer 12.3 Kg./Sq.Cm. (175 PSI) 3.5 TO 10.5 Kg./Sq.Cm. (50 to 150 PSI) ¾" BSPT (¾" NPT OPTIONAL) Housing & Scroll - Brass IS : 291 ( EQUIVALNET TO ASTM-B21) INCLUDED WATER SPRAY K-FACTOR SPRAY ANGLE AND ANGLE METRIC(US) K-FACTOR 75 22 (1.54) 80 18 (1.26) 90 32 (2.24) 100 26 (1.82) WEIGHT FINISH APPROVALS ORDERING INFORMATION Approx. 0.200 Kgs. Brass Finish Nickel Chrome Plated (optional) UL Listed Specify Model, K-Factor, Spray angle and Finish. The nozzle may be oriented in any position as deemed necessary to cover the hazard. MAINTENANCE The spray nozzle must be handled with due care. For best results, the storage as well as any further shipment be made in original packing only. Nozzle which is visibly damaged should not be installed. Use Teflon tape or soft thread sealant on the male thread of the nozzle. APPLICATION High Velocity Water Spray Nozzles are internal swirl plate type open nozzles designed for use in fixed water spray or deluge system for the fire protection application. These nozzles produce solid uniform and dense core of high velocity water spray to effect fire control. Nozzles are normally used to cool the surface as well as for extinguishment. Nozzles are typically used for Deluge protection of special hazards such as oil filled transformers, switch-gear, chemical process equipments, conveyor system and flammable liquid storage areas..the minimum desirable pressure to achieve a reasonable spray pattern is 3.5 Kg./sq.cm. (50 psi). The water distribution pattern as shown in the graph in following pages giving maximum effective axial distance from the nozzle. The spray pattern shown is with indoor application. The system designer must consider wind velocity while designing the system for outdoor application. Field obstruction if any affecting the spray pattern of the nozzle must be considered. It is recommended that the water spray system be inspected by an authorised technical personnel. The nozzle must be checked for corrosion, external and internal obstruction, blockage if any. The nozzle should be cleaned or replaced if required. The system must be operated with optimum water flow at least three times in a year or as per the provision of NFPA/TAC or local authority having jurisdiction. The owner is solely responsible for maintaining the water spray system and components therein, so that it performs properly when required. PAGE 1 OF 4

DIMENSION In millimetres ( Approximate ) NOZZLE FACTOR & SPRAY ANGLE A B C (A/F) K 22 x 75 49 21 30 K 18 x 80 44 21 30 K 32 x 90 49 21 30 K 26 x 100 55 21 30 DISCHARGE CHARACTERISTICS PAGE 2 OF 4

SPRAY PATTREN K22 X 75 K18 X 80 K32 X 90 Note : One square is 200 X 200mm. PAGE 3 OF 4