MANUAL. MiniMax V / VK

Similar documents
MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGERS. MicroStart. IBC control

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

Technical data. WARNING! Residual voltage is present for 1 minute after disconnecting mains voltage.

University of Houston Master Construction Specifications Insert Project Name SECTION ELECTRONIC VARIABLE SPEED DRIVES PART 1 - GENERAL

Softstarter Intelligent Controllers

J1000. Compact Inverter Series.

DKG-114 MANUAL AND REMOTE START UNIT

PUR (A, B, C, D) INSTRUCTION FOR VARIABLE SPEED WITH WIRING DIAGRAM FOR EMX P10 ROTOR SIZE

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

TRIPS AND FAULT FINDING

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

825-P Modular Protection System for motors Specification Guide

RVS-DN Digital Reduced Voltage Motor Starter

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

RVS-AX Instruction Manual

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

Designed for ease of integration with automation systems

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

Type SOQ Negative Sequence Time Overcurrent Relay

Quick guide. Plug-in fans GPPM with FC101_106 August 2014


A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

SECTION MOTOR CONTROL

Variable speed application guidelines

Quick Start Guide of CV50- ControlVIT Series

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

Models. Output current max.* Output Power max. Low Line : VAC High Line: VAC 24 VDC / 12 A 240 W. Back up battery

HIB Enclosed Inverter User Guide

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Instructions for the BCEA Rotary heat exchanger

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (0-10VDC Input Version)

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

RVS-DX Digital Reduced Voltage Motor Starter

KD LV Motor Protection Relay

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

FE100/FE200. Inverter

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3.

GENSET CONTROL MODULE A121H / A241H. User selectable time delays for engine start and engine stop (cool down).

DEEP SEA ELECTRONICS PLC

PUR (A, B, C, D) INSTRUCTION FOR VARIABLE SPEED WITH WIRING DIAGRAM, EMX-R ROTOR SIZE TECHNICAL DATA

EC DECLARATION OF CONFORMITY

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION MOTORS, STARTERS & DRIVES

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

MAGNETIC MOTOR STARTERS

Fincor Series 2230 MKII/2240

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

ECONOVENT Rotary heat exchanger Instruction for variable speed EMX-R PUM with wiring diagram

Reverse power relay and protection assemblies

SPECIFICATIONS UPS Triple Output 13.6VDC/213W, 48VDC/153W, 48VDC/39W

UL/cUL FILE NUMBER E CE See last page of manual for CE Declaration of Conformity.

DEEP SEA ELECTRONICS PLC

USERS MANUAL MCD REMOTE OPERATOR

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

MaxPak Plus Analog DC V S Drive

702 AUTOMATIC START MODULE OPERATING INSTRUCTIONS

ADD-ON REMOTE STARTER TO AFTERMARKET SYSTEM

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

Possible to create the highest level safety system

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

AKM 105, 115: Rotary actuator for ball valve

Brushless DC Motor Systems FBL2 Series

PERFORMANCE LOAD HP AMPERES RPM % % SPEED TORQUE RPM TORQUE TORQUE AMPERES % FULL LOAD LB-FT

Control Power V AC, 50/60 Hz 150-C30NBD 150-C30FHD

Ion Technologies SUMPRO Battery Back-Up

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Motor-drive mechanism, type BUL. Technical guide

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

EA07. Generator Automatic Voltage Regulator Operation Manual

Components for EEx e Panels

Submittal Data Information

Commissioning Instructions Inbetriebnahme Anleitung VB 230/ L (LP)

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

TD1512AX Technical Data. REMOTE MOUNT SOLENOID DRIVER (4-20mA Input Version)

Fire Fighting Diesel Pump Control Panel in Compliance with EN Standard User Manual

ABB Component Drives ACS150, 0.5 to 5 Hp

MODEL 422 Submersible Pump Controller

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

Three-Phase Soft Starters

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Technical Data Accessories MCBs Ex9B.

SDS Enclosed Star-Delta Starter User Guide

Power Controller. (see note 1) 10 sec

GENSET CONTROL MODULE A121A / A241A

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Flight Systems. Replacement for KASSEC DESCRIPTION

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

Features IN THIS CHAPTER

Low voltage AC drives

Transcription:

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER MiniMax V / VK Revised 2014-10-07 Version 1.3.1 F21037901GB

Declaration of Manufacturer The manufacturer s assurance of the agreement of the product with the demands in the EMC DIRECTIVE 2004/108/EG. Manufacturer Product Model EC directives applied to the product IBC control AB Brännerigatan 5 A, S-263 37 Höganäs Control unit for rotating heat exchanger MiniMax V/VK All control units are approved in accordance with the demands as specified in the EMC-directive 2004/108/EG and are tested according to standard EN 61800-3:2004, Emission Category C1 and Immunity Category C2. All control units follow the low voltage directive 2006/95/EG, standard EN 61800-5-1. The manufacturer assures on his own responsibility that the product which this assurance concerns corresponds with the demands in the EC directives stated above. This product is corresponding to the RoHS-directive. IBC control AB Höganäs 2010-03-17 Christer Persson VD To meet the requirements of the EMC regulations a shielded cable must be used for both motor and control signal. The screen must be connected in both ends. IBC control Brännerigatan 5 A SE-263 37 Höganäs Tel. +46 42 33 00 10 Fax +46 42 33 03 75

Users guide: MiniMax V / VK MiniMax V open MiniMax VK enclosed Contents Wiring details Description of functions General data Control connections Manual test Adjustments Adjusting DIP-switches Checks before power on Starting procedure Operational indications Alarm indications Protective and operational functions 2 3 4 5 6 Fault finding 7 1

Wiring details C ontrol term inal block A1 A2 A3 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 H I G H L O W w b + - M anual high speed and low speed Voltage / current R un Input therm al contact Input rotation m onitor R eset O utput alarm relay O utput control relay ( M ax 8A / 250V A C ) Potentiom eter input Frequency Pow er connection 1 2 3 3 4 L N U V W - + P ot. 0-140 ohm 0-10k ohm 0-10V D C is equivalent to 0-100 H z Input 1 x 230V O utput 3 x 230V Description of functions MiniMax (V - open IP20, VK - enclosed IP54) is a modern vectormodulated frequency inverter with all additional functions which are necessary to control rotating heat exchangers. Accepts all available control speed reference signals. The speed of the heat exchanger and its efficiency are controlled by the frequency inverter, so that the speed of the rotor is in proportion to the input signal from the central control. If the input signal is under the adjusted threshold value the rotor will stop. When the rotor has been still for 30 minutes the cleaning function engages and the rotor will rotate at 10 sec per min. speed. The rotation monitor (magnet which is assembled on the rotor and the integral magnetic transmitter) will stop the frequency inverter and give alarm at belt breakage or similar disorders. Over- or undercurrent or open thermal contact will stop the frequency inverter and give alarm. General data Max. motor size 370 W Acceleration time 1-30 s Max. cont. output current 2,2 A Deceleration time 1-30 s Max. overload 2 min./30 min. 3,5 A Ambient temp. (non condensing) 0-45 o C Supply input voltage 1x230,+/-10% V Protection rate V:IP 20, VK:IP 54 Supply input frequency 50 60 Hz Weight V: 1,2, VK: 1,4 kg Output voltage 3 0-230 V Dimensions h x w x d V:155 165 67 mm Output frequency 1-100 Hz VK:195 165 67 mm Min. frequency 1-20 Hz Input fuse max. 10 A Max. frequency 40-100 Hz 2

Control connections Manual high speed (A1-A2) Manual low speed (A2-A3) Input signals (1-3) Frequency measurement (3-4) Run (5-6) Thermal contact (7-8) Rotation monitor (9-10) Reset (11-12) Alarm relay (13-14-15) Control relay (16-17) Cooling recycling. Will give adjusted max speed if run (5-6) is closed. Defrosting. Will give adjusted min. speed if run (5-6) is closed. Adjusted to central control. (0-5V, 0-10V, 1-5V, 2-10V, 5-10V, 10-0V, 10-2V, 10-5V, 0-20 V Phase cut, 0-20mA, 4-20mA). See adjusting DIP-switches, page 4. 0-10VDC relates to 0-100Hz. Dvs 0,5V = 5Hz, 5V = 50Hz. The speed of the rotor is proportional to the frequency. Must be closed if external start is not being used. Must be closed if the thermal contact in the motor is not being used. White wire to number 9, brown wire to number 10. The magnet should be mounted with southpole against the transmitter. Max distance 15 mm. The inverter trips if it does not receive pulses every 5 minutes. The function can be disabled. See DIP-switches, page 4. Remote reset of alarm. The inverter resets automatically when input power is disconnected. Connected between 14-15 when alarm or power is off. Connected between 16-17 when run is enabled. Max. 8A/250V AC. Manual test Button high speed Button low speed The motor rotates with adjusted maximum speed. The motor rotates with adjusted minimum speed. 3

Adjustments Boost Acc Ret Threshold value Min rpm Max rpm Adjusts the low speed torque. Adjusted before delivery. May be increased if needed but will increase the motor temperature at low speed. Time of acceleration (0-30 sec). Adjusted to max. before delivery. Will not require adjustment. Retardation time (0-30 sec). Adjusted to max. before delivery. Will not require adjustment. The inverter does not start until the speed reference signal exceeds the threshold value, which is adjustable between 0 and 20 % of the maximum input signal. For example at chosen input signal 0-10 V the threshold value is adjustable between 0-2 V. Min. speed (1-20Hz). Adjusted before delivery to 4 Hz. Max. speed (40-100Hz). Adjusted before delivery to 50 Hz. Adjusting DIP-switches 1 2 3 4 5 6 7 8 Potentiometer 0 0 0 0 0 0 0-5 V 0 0 0 0 0 0 0-10 V 1 0 0 0 0 0 DIP-switch ON (1) 1...8 OFF (0) 0-20 V 0 1 0 0 0 0 1-5 V 0 0 1 0 0 0 2-10 V 1 0 1 0 0 0 5-10 V 1 0 0 1 0 0 10-0 V 1 0 0 0 0 1 10-2 V 1 0 1 0 0 1 10-5 V 1 0 0 1 0 1 0-20 ma 0 0 0 0 1 0 4-20 ma 0 0 1 0 1 0 Cleaning function off 0 Cleaning function on 1 Rotation monitor off 0 Rotation monitor on 1 4

Checks before power on Check that the motor is connected for 3 x 230 V. If a security switch is connected between motor and inverter, the thermal contact of the motor must be connected through auxiliary contact in the security switch. Check that the inverter is connected according to pages 2-3. Input power 230 V +/-10%. Check that Check that DIP-switch is adjusted for the correct speed reference signal. See adjustment of DIP-switch, page 4. rotation monitor and cleaning function is connected. See adjustment of DIP-switch, page 4. Starting procedure Must be done in the given order Check that Adjustment of max. rpm Adjustment of min. rpm Check of rotation monitor Adjustment of threshold value Cleaning function Finally the motor rotates in the correct direction in relation to the rotor rotating direction. Use pushbutton "High speed", alternatively connect A1-A2 and "Run" 5-6. Adjust "Max rpm" so the rotor rotates at 10-12 rpm (or according to the manufacturer of the rotor). Remove, if any connections before next adjustment. Use pushbutton "Low speed", alternatively connect A2-A3 and "Run" 5-6. Adjust "Min rpm" so the rotor rotates at 0,5-1 rpm (or according to the manufacturer of the rotor). Remove, if any connections before next adjustment. Use pushbutton "high speed". Yellow led diode (2) flashes when magnet passes magnetic transmitter. Make sure that the central control is connected. Connect "Run" 5-6. Adjust min. outsignal on the central control. If the rotor still rotates, increase the threshold value until it stops. Check when power is on. If cleaning function is on and the speed reference signal is lower than the threshold value, the rotor will start immediately with cleaning function when power is on. Let the central control run the rotor at max- and min speed and check that the speed of the rotor is correct. 5

Operational indications Green led Yellow led 1 Yellow led 2 Indicates: "Voltage on". Flashes when the inverter trips. Indicates run. Lights when heat exchanger rotates. Flashes when rotation monitor is affected. Regardless of adjustment of DIP-switch. Alarm indications Conditions remain on Red led 1 Red led 2 Red led 3 Red led 4 Red led 3 + 4 Indicates that the inverter has tripped due to rotation monitor fault. Indicates open thermal contact. Indicates overvoltage. Inverter trips after 7 sec. Indicates undervoltage. Inverter trips after 7 sec. Indicates overcurrent /short circuit/earth fault. Protective and operational functions Over-/undervoltage Overload current Short circuit Cleaning function Restart Disconnection The inverter trips at 250 V resp. 190 V. Delay 7 sec. The inverter limits the current at 4.0 Amps. The inverter limits the current when short circuit occurs between phase/phase or phase/earth. The heat exchanger rotates at min. speed for 10 sec. every 30 min. if the speed reference signal is less than the threshold value, i.e. the rotor stands still. This function can be disabled, see adjustment of DIP-switch, page 4. Automatic restart after main failure. Disconnection between inverter and motor is not allowed when motor is under load. 6

Fault finding Green led flashes and the indicated red led is on, -inverter has tripped due to: Rotation monitor Thermal contact trip Overvoltage Undervoltage Belt breakage - Belt skids - Magnetic transmitter or the magnet is out of order - Magnet turned the wrong way (wrong polarity) - Magnet transmitter connected wrongly - Min. speed adjusted too low (frequency too low for the motor to be able to work). Too high winding temperature in the motor. Thermal contact resets when temperature returns to normal level. Input power is over 250 V, for more than 7 sec. Input power is under 190 V, for more than 7 sec. In above mentioned cases the inverter must be reset via connection block 11-12, alternatively restarted. The rotor has not the power to start, alternatively has not the energy to come up to speed. Inverter limits the current Too short acceleration access ramp - Too large rotor/too small motor - rotor inactive - Motor out of order/incorrect storage/winding fault/short circuit (measure the co-resistance, should be approximately equal on all phases). Measure the power. If the motor will not start at all. Do test drive with high - and low speed buttons to check that the inverter is correct. Check speed reference signal from central equipment. Connect 5-6, check operation conditions. Check output voltage on the inverter phase-phase (U-V-W). Voltage should be approximately the same between all three phases. Under 50 Hz the voltage is less than 230 V between the phases. 7

8

9

Brännerigatan 5 A SE-263 37 Höganäs Tel. +46 42 33 00 10 Fax +46 42 33 03 75 IBC control Brännerigatan 5 A SE-263 37 Höganäs Tel +46 42 33 00 10 FAX +46 42 33 03 75