Automation Swing Gate Opener

Similar documents
Automation Swing Gate Opener

SWING GATE OPENERS 24V DC GEAR MOTOR

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

PW320/PW330 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR FOR RESIDENTIAL. Flashing Light. Push Button. Control box. Gate 2.

PW150/PW200 USER MANUAL SWING GATE OPENERS 24V DC GEAR MOTOR

EC MACHINE DIRECTIVE COMPLIANCE DECLARATION

MASTIFF 300/300M SWING GATE OPENER USER MANUAL

FORCE SPD 800/1500/2000

Installation manual ASTER AUTOMATION FOR SWING GATES 11_16

INSTALLATION MANUAL ACE. Gearmotor for swing gates 01_17

Contents. EC DECLARATION OF CONFORMITY FOR MACHINES... p. 10. WARNINGS FOR THE INSTALLER... p. 10

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC) WARNINGS FOR THE INSTALLER

EC DECLARATION OF CONFORMITY FOR MACHINES (DIRECTIVE 98/37/EC)

D Vers. 03 ELECTROMECHANICAL AUTOMATION FOR SWING GATES

Porte 300 Users Manual Swing Gate Opener 24V DC for residential use only

ARACHNE 230V 24V- 12V

Installation Manual. Swing Gate System. Leading the way...

Porte 150 Users Manual Swing Gate Opener 24V DC

MOTORS RESIDENCIAL / INDUSTRIAL

EC DECLARATION OF CONFORMITY FOR MACHINES WARNINGS FOR THE INSTALLER

INSTALLATION MANUAL ENGLISH ALPHA 200 ALPHA 330. L C (stroke) 960 mm 1160 mm

is250/is250d/is250solar SWING GATE OPENER MANUAL

HYDRAULIC SWING GATE OPENER

SLIDE & OL USER'S AND INSTALLER'S MANUAL V1.0 REV. 06/2017

Swing Type EM3 Plus EM 3 EM 2. Max. Piston Stroke 450 mm 350 mm 200 mm. Max. Length of motor 1255 mm 1030 mm 730 mm

Recommended control units: Mindy A824/110. Aluminium Nice release: user-friendly, effortless, sturdy. Flashing light. Digital or key switches

V200 USER MANUAL SWING GATE OPENER. 100kg 1.5m. 100kg 1.5m

IRREVERSIBLE OPERATOR FOR SWING GATES AND DOORS

access

INSTALLATION AND OWNER S MANUAL MODEL ASW Actuator Swing Gate Operator

EC DECLARATION OF CONFORMITY

Automation systems for swing gates hydraulic

SARGON S - M - L. All rights reserved INSTALLATION MANUAL

MEKO OPENER FOR RACK-DRIVEN SLIDING MOTOR

NICE TOO, STYLISH AND VERSATILE NEW TELESCOPIC GEARMOTOR FOR SWING GATES. THE IDEAL SOLUTION FOR RESIDENTIAL OR PEDESTRIAN GATES.

ARTICULATED ARM GATE OPENER USER MANUAL

Nice TTN3724HS TTN3724RHS TTN6024HS TTN6024RHS

Ditec CUBIC Swing gates automation

SLIDING GATE OPENER USER MANUAL

Installation manual. English. mystrike OPENER FOR RACK-DRIVEN SLIDING MOTOR

KUSTOS ULTRA BT KIT A40 FRA

Complete range of electromechanical pistons for residential use, suitable for swing gate leaves up to 4 metres wide and weighing up to 500 kg.

Corso Principi di Piemonte, 65/ RACCONIGI (CN) ITALY tel fax

Type of installation. external motor. underground motor. Leaf max length (m) Leaf max length (m) Max leaf weight (kg) V V V

Sectional and Tilting Door Opener Installation Instructions and User Guide

Electromechanical gear motor for sliding gates ACHILLES

FITTING AND CONNECTION INSTRUCTIONS

SWINGING GATES Electromechanical automation systems for swinging gates

Ditec LUXO Swing gates automation (Original instruction)

CICLÓN ATTUATORE ELETTROMECCANICO IRREVERSIBILE A BRACCIO SNODATO PER CANCELLI A BATTENTE

L /2012 rev 0 BISON 45 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

OPENING THE WORLD SWING SWING GATE OPENER USER MANUAL

SWING GATE OPENERS 24V DC GEAR MOTOR

INSTRUCTIONS FOR INSTALLATION

CATALOGUE. Professional

MX- Serries Barrier gate Catalogs

JOINT INSTALLATION MANUALS AND SAFETY INFORMATION

WEL. Manuale di installazione e manutenzione per automazioni per porte battenti. Installation and maintenance. for swing doors.

INSTALLATION MANUAL FOR SWING SHUTTERS KAF212. FACE S.r.l. Viale delle Industrie, Dosson di Casier Treviso Italy

SL100DCx series Sliding gate system Installation guide

DESIGNED FOR RESIDENTIAL APPLICATION KIT PL600/PL1000 SLIDING GATE OPENERS

BH30 SERIES Today s digital intelligence moves your gate

TOONA 5 HS. Quick manoeuvres: 90 opening in about 16* seconds.

Ditec PWR50H/HV/HR Automation for swing gates

AUTOMATION SYSTEM FOR SWING GATES FROG SERIES INSTALLATION MANUAL SUPERFROG

Ditec PWR25H/35H Automation for hinged gates

Sectional and Tilting Door Opener

For sectional and up-and-over doors. 118 Spinbus 122 SpinbusKit 20/21/ SpinbusKit 23. For up-and-over and articulated doors.

UNDERGROUND OPERATOR FOR SWING GATES 119AS45EN. Installation manual FROG-A / FROG-AV / FROG-AE. English

BULL 424 ESA BULL 624 ESA

L /2012 rev 0 BISON 30 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI

Easy. Easier. Mhouse.

How to select your fastening screwdrivers?

Index. 4 DESCRIPTION... p. 5 5 PRELIMINARY CHECKS... p. 5 6 ASSEMBLY... p. 6

BULL 5M - BULL 5M.S BULL 8M - BULL 8 M.S BULL 8 OM - BULL 8 OM.S

Ditec PWR Automation system for swing gates with wings up to 5 metres

BL240 BL240 - (15400) Operatore elettromeccanico lineare ISTRUZIONI PER L INSTALLAZIONE

TECHNICAL CATALOG NEPTIS INVERS/INVERS-B ELECTRO-MECHANICAL OPERATOR FOR AUTOMATIC SWING DOORS, WITH SINGLE/DOUBLE LEAF

FEATURES AND SPECIFICATIONS

HÖRMANN DSA 100 DSA 100 L DSA 200 DSA 200L. page 1

RAPIER DSB Disconnectors

Control panel installation manual for 230 V~ automation with one or two motors D5 S5 JT RF ON TC RP TR R1 OM J7. Electric lock. Flashing light.

ALPHA 200 PLUS ALPHA 330 PLUS INSTALLATION MANUAL

UNDERGROUND OPERATOR FOR SWINGING GATES. WARNING!! Before installing, thoroughly read this manual that is an integral part of the pack

Amico. new. Above ground operator for swing gates of up to 1.8 m per gate leaf. A new concept in safety

BARRY BARRIER GATE AUTOMATION

L /2013 rev 0 BISON 35 OTI UNIONE NAZIONALE COSTRUTTORI AUTOMATISMI PER CANCELLI, PORTE SERRANDE ED AFFINI


Typical Installation Schematic

F ERNI K I T THE FERNI-S KIT CONSISTS OF:

Compact Sliding Door Operator Dor-O-Matic 2900 Series

Saimatic Aster Gate Operator, Automation System Manual. 110V or 220V

SYSTEMS FOR SLIDING GATES

Istruzioni, instructions. Motoriduttore a braccio snodato per cancelli battenti Gear motor with articulated arm for swing gates ALPHEO

TELCOMA OPENS UP TO THE FUTURE. NEW T600-T624 EVOLUTION OF THE SPECIES. PRG-LINK THE FUTURE IS CONNECTED. STEALTH AN ELEGANT PERFORMER.

ASW-400. Installation Manual. Downee

SECTIONAL AND TILTING DOOR OPENER INSTALLATION INSTRUCTIONS AND USER GUIDE. Comfort 800E/1000E

GROUND GROUND - ( ) Interrati elettromeccanici ISTRUZIONI PER L INSTALLAZIONE. Electromechanical underground INSTRUCTIONS FOR INSTALLATIONS

CE DECLARATION OF MACHINE CONFORMITY

THE CHAMPION OF AUTOMATION

Transcription:

Automation Swing Gate Opener Operating and installation instructions Elegant 3

CONTENTS ) DESCRIPTION ) TECHNICAL SPECIFICATIONS 3) THE INSTALLATION TOOLS 4) THE PACKING LIST 5) THE INSTALLATION

.DESCRIPTION The ELEGANT 3 automated system for swing gates comprises an electromechanical operator which drives the gate leaves by means of a worm screw. The ELEGANT 3 operator is irreversible and locks mechanically when the motor is not in use, there for a lock does not need to be fitted. ATTENTION: The ELEGANT 3 automated system was designed and manufactured to control access of vehicles. Avoid any other use whatever. The control systems must be installed at a minimum height of.5m from the ground surface and not interfere with the mobile parts. Command pulses must be given from sites where you can see the gate. Use transmitters only if you can see the gate.. Features of this product: This product is configured with an advanced automation control system, allowing many years of fault-free, easy and safe operation. This product adopts advanced driving mode and most suitable driving system, eliminating safety hazards. This uses a DC motor with low noise. This product features fully automated soft start and shutdown, and stable and quiet operation. This system is provided with obstacle detection, stopping and backing functions to protect nearby personnel and property. This product is configured with internal interfaces of complete functions and plug-and-play operation. This product has most prevailing outline structural design. External parts of this product are elaborately treated to prevent accidental injury due to touching. This product has elaborately designed installation structure to facilitate installation. This product has elaborately designed internal structure to facilitate maintenance.. Structure of this product:.. The dimension of the shape:.. The internal structure: (fig.0) fig.0 fig.0.rear bracket.external arm 3.Motor 4.Pin 5.Spring 6.Arm 7.Dish 8.Dish 9. Bearing 0. Wormscrew. Bearing. Downboard 3. Longscrew 4. Lockcover 5. Screw 6. Screw 7. Lockboard 8. Lock 9. Upboard 0. Screw. Bearing. Front fitting

. TECHNICAL SPECIFICATIONS. Technical specifications TECHNICAL SPECIFICATIONS Power supply (V) Power (W) Thrust (dan) Current (A) Speed (m/sec) Travel (mm) Max Leaf weight (Kg) Protectionc l a s s Working temperature ELEGANT 3 DC4V 4W 400N A 0.8m/s 400mm 00Kg IP54 >-0ºC, <50ºC 3. THE INSTALLATION TOOLS There are some operating tools before installation as follow: (fig.03) fig.03 4. THE PACKING LIST You must check the operator packing before the installation of the automated system. (fig.04) fig.04 NO NAME AMOUNT NO NAME AMOUNT Gearmotor 8 Screw 3 Control Box Door Bracket 9 0 Pin Bracket 4 5 6 7 Wall Bracket Rear Bracket Remote Control Key 3 4 Exp a n d e d s c r e w Exp a n d e d s c r e w Lock screw (M6) Lock screw (M8)

5. THE INSTALLATION 5. Pre-installation checks ATTENTION: To ensure a correct operation of the automated system, make sure the following requirements are observed as for the gate structure (existing or to be realised) The leaf must be fixed firmly on the hinges to the pillars and must not be flexible during the movement Rotating gate shall be solid wood gate, metal gate or glass aluminum gate; Before the installation of ELEGANT 3, verify all dimension, etc. The mechanical parts must conform to the provision of standards EN604 and EN605. Leaf length in compliance with the operator specification. Sturdy and stiff structure of the leaves, suitable for automation Regular and uniform movement of the leaves, without any friction and dragging during the en t i r e o p e n i n g. Presence of an efficient earthing for electrical connection of the operator Rotating gate shall be two-leaf, and the stops must be added in the path. 5. Installation layout 3 5 4 fig.05 fig.06. Operators. Photocells 3. Con t r o l b o a r d 4. Ke y - o p e r a t e d p u s h - b u t t o n 5. Receiver 6. Fl a s h i n g l a m p NOTE. Use suitable tubes and/or hoses to lay electric cables. To avoid any kind of interference always separate low-voltage accessories and control cables from 30V power supply cable using separate sheaths. If not standard layout, all equipment must be carefully selected. 5.3 Door opening angle and depth parameters Max. 0 for this product; if this shall be 90, a stop must be added in the path. angle 90 00 0 0 depth m a x 70mm 40mm 40mm 0mm fig.07 Adjust opening to your preference. This left figure shows an example of such case (maximum opening angle is 90 ). (fig.08) fig.08

5.4 Minimum installation gate opening clearance Rotating gate must not be in contact with wall (to avoid potential hazard); minimum clearance between gate and wall shall be 00mm to avoid injury; Gate opening is adjusted by stopper; stopper can be used to adjust distance between gate and wall, while adjusting opening angle. To allow max. angle of opening, make sure to treat walls. Installation for inward opening of gate. 5.5 Minimum installation height fig.09 This system is fully electrically driven; output is at bottom where there is potential hazard; do not get near. Output device of this system is at bottom and certain installation requirements apply. Bottom of compound box shall be at least 50mm to ground. Installation for outward opening fig.0 5.6 Minimum side clearance System fully electrically driven. Driving arm has certain rotation radius (with potential hazard). Don t stay near. Driving arm has large rotation radius and certain installation requirements apply. Driving arm shall be at least 500mm to walls. fig. fig. Inward opening installation side clearance fig.3 Outward opening installation side clearance 5.7 Gate opening angle commissioning parameters 5.7. Installation depth D 5.7. Installation translation distance B fig.4 fig.5 fig.6

(EN) B Support (EN) A Support stroke engine ELEGANT 3 W X Y Z 95º 770 50 00 400 0º 770 00 50 400 5.7.3 After fixing machine slide rod on fixing plate, use marker pen to mark on the gate. Drill holes at markings on the gate and use spare screws to lock the fixing plate. fig.7 fig.8 ATTENTION: At lower part of the gate opening machine, pointed part is system clutch. In case of fault or loss of power, use key to open the clutch. Key Lockbox c o v e r fig.9 fig.30

Before installing fixing support, drill mounting holes on wall with electric drill and embed expansion tube in wall. Then put fixing support horizontal and use screws to lock mounting plate. During locking of mounting plate, fixing support must be adjusted horizontal. fig.35 5.7.4 Prepare gate opening machine and use a spare V power supply or battery to push slide rod to its position. Me t h o d o f connection Directionof d o o r o p e n i n g b y t h e m a c h i n e fig.36 fig.37 5.7.5 According to commissioning parameters, installed fixing support on main unit of gate opening machine. fig.38 5.7.6 After fixing machine slide rod on fixing plate, use marker pen to mark on the gate and drill holes on markings on door and use spare screws to lock fixing plate. fig.40 fig.4