Delta Sensorless Vector Control Compact Drive VFD-E Series

Similar documents
Delta Sensorless Vector Control Compact Drive VFD-E Series

Water Circulation Pump Control

Machine Tools Delta's C200 series provides precise speed control, excellent low speed torque output and high durability to meet machine tool requireme

Delta Planetary Gearbox PA Precision Series

Delta Sensorless Vector Control Compact Drive VFD-EL Series

Automation for a Changing World. Delta AC Servo Drive ASDA-A2-E Series

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

Delta Planetary Gearbox PS High Precision Series PA Precision Series

Delta Hybrid Servo Drive VFD-VJ Series

Datasheet VFD-CP2000. Type number key A B C S -XY VFD 007 CP 43. Option cards. Slot 3

ME300 Series. Delta Basic Compact Drive. Automation for a Changing World. Optimized Space Utilization. High Safety and Stability.

GS2 Series - Introduction

Quick Reference Guide. For NFX9000 Adjustable Frequency Drives. February 2006 NQ00. MN E February 2006

Delta Products VFD CP2000 Bypass Control Packages.

Delta Hybrid Servo Drive VFD-VJ Series

VFD E Series. Features

J1000. Compact Inverter Series.

Delta Active Front End AFE2000 Series

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Automation for a Changing World. Delta Compact Elevator Drive MH300-L.

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Delta Vector Control AC Motor Drive

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

IP 20/NEMA 1 & IP 66/NEMA 4X Compact Vector Control Drive

Delta Hybrid Servo Drive VFD-VJ Series

Description 1/8-7.5HP

RS232 Communications cable with PC ER M. RJ-45 / USB Adapter Remote Operator Extansion Cable. Communication Unit. Mounting Accesories

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

Automation for a Changing World. Delta Basic Compact Drive. ME300 Series.

MX1S Matrix Converter

Varispeed J7 CIMR-J7AZ. System configuration

SYSDrive Frequency Inverter

Low voltage AC drives

2.3. Adjustable Frequency Drives. Contents. Standards and Certifications

LIFT INVERTER SERIES L1000V DE ES FR IT 1000V L1000V L1000V L1000V L1000V

Shenzhen Sine Electric Co., Ltd.

L300P Inverter Specifications

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

CIMR-V7AZ Varispeed V7

V1000. Inverter Series.

V1000 Inverter Series

Delta Fan/Pump Vector Control Drive CP2000 Series

HVAC Products. Introducing the SED2 Variable Frequency Drives

Chapter 1: Getting Started User Manual Overview...1 2

Phoenix DX Sensorless AC Vector Drive. 3 HP to 3500 HP

REGAL-BELOIT SpinMaster AC Adjustable Speed Drives

Symbol Input rating Symbol 2 Three-phase, 200 ~ 230V N 4 Three-phase, 380 ~ 480V. None. Loader. Graphic. Loader

Experience & Innovation

Delta AC Servo Drive ASDA-A2-E Series

Quick Start Guide of CV50- ControlVIT Series

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

High performance Vector Control. Ratings. System configuration

YASKAWA AC Drive Compact V/f Control Drive J1000

P-SERIES VFD WITH BYPASS

VSD Series II Variable Speed Micro Drives

SJ300 Inverter Specifications

HIGH PERFORMANCE VECTOR CONTROL DRIVE

AS THE TIME GOES BY WE HAVE CONSTANTLY MADE QUALITY A TOP PRIORITY

Variable Frequency Drive NEW! Moving your Control. Forward VFD from Unitronics kW Single Phase kW Three Phase

Technical Information

New. High Performance Inverter FUJI INVERTERS 24A1-E-0042

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Preface DANGER! PLEASE READ PRIOR TO INSTALLATION FOR SAFETY.

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

SHENZHEN KEWO ELECTRIC TECHNOLOGY CO., LTD

PSE The efficient range Description

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

A V Class: ½ to 175 HP 480V Class: ½ to 1000 HP 600V Class: ½ to 250 HP

3G3JX AC DRIVES. Compact and complete. »» Cost a n d e co-friendly. Downloaded from Elcodis.com electronic components distributor

LIFT INVERTER SERIES L1000A

Main Features of Varis

MULTI LANGUAGE KEYPAD

www. ElectricalPartManuals. com Instruction Bulletin ALTIVAR FLEX58 TRX Adjustable Speed Chassis Drive Controllers Installation Guide

A1000 D E A1000 A1000 A1000 A1000

690+ Series Integrator

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

BR Second Position Voltages. AA Fourth Position

USB Copy Unit COM ERR. Copy. RJ-45 / USB Adapter. Verify. Read LOCK YASKAWA JVOP-181. Remote Operator Extansion Cable. Communication Option Board

Frequency inverters overview

HYUNDAI INVERTER Powerful Operation & High Performance

Technical Explanation for Inverters

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Delta Hybrid Servo Drive VFD-VJ Series Servo Motor MSJ/MSO Series

Large Drive. Variable Speed Control is Just the Beginning. Franklin FastApp Firmware. Variable Speed Control NEMA. Standard Features (Enclosed Drives)

3-phase 400 V 0.4 to 630 kw. High Performance Multifunctional Inverter

CATALOG. ABB micro drives ACS55, 0.18 to 2.2 kw

Low voltage AC drives. ABB micro drives ACS to 3 hp/0.18 to 2.2 kw Catalog

High on intelligence big on reliability AC Drive

V1000 DE ES FR IT V1000 V1000 V1000 V1000

MX2-Series V1 type. kw VT motor capacity

ALTIVAR 58 AC Drives

CHAPTER 7 ERROR MESSAGE AND TROUBLESHOOTING

V1000. AC Drive Series.

Powerdrive FX Ultra compact regenerative drive solution

ALTIVAR 18 AC Drives. File 8805

Start-up guide of LSLV-M100

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

V1000. YASKAWA AC Drive. Compact Vector Control Drive

Frequency Inverters SJ Series Type P1

Transcription:

Automation for a Changing World Delta Sensorless Vector Control Compact Drive VFD-E Series www.deltaww.com

Features Modular Design Modular structure and extension with optional cards RFI Switch for IT Mains Removable "Y" capacitor to use with IT mains supplies Standard MODBUS Protocol Standard MODBUS protocol via RS-485 Built-in EMC Filter (230V single-phase and 460V 3-phase) Efficiently reduces electromagnetic interference Easy DC Bus Sharing Multiple VFD-E units can be connected in parallel to share regenerative braking energy. It prevents over-voltage and stabilizes the DC bus voltage Compact Design Space saving and easy DIN rail mounting with optional DIN rail adapter Optional Fieldbus Modules Provide connection to a variety of networks, including PROFIBUS, DeviceNet and CANopen Complete Protection Functions High precision current detection, full overload protection (ol, ol1 and ol2), overvoltage/ overcurrent stall prevention, short circuit protection, reset after fault, speed search function and motor overheat protection by PTC Flexible Extension Via optional cards, such as I/O card, Relay card, PG (Encoder) card and USB card, to meet your application requirements Removable Keypad The standard keypad acts as a status monitor. More functions, including parameter modification, RUN/STOP, speed change, and status display, are available via an optional keypad 1

Built-in PLC Function PLC programming and editing capability without the need of an actual PLC Side-by-side Installation (40 o C) High-efficiency cooling and flexible spacing Power Range Single-phase115 V series: 0.2 ~ 0.75 kw (0.25 ~ 1 hp) Single-phase 230 V series: 0.2 ~ 2.2 kw (0.25 ~ 3 hp) 3-phase 230 V series: 0.2 ~ 15 kw (0.25 ~ 20 hp) 3-phase 460 V series: 0.4 ~ 22 kw (0.50 ~ 30 hp) Easy Maintenance Removable cooling fan for easy maintenance Applications Vacuum compressor Outstanding overload capability of VFD-E reduces the impact of sudden load increase to the vacuum compressor Escalator Built-in PLC function and multi-step speed control provide energy saving escalator performance and save the cost of purchasing a host controller 2

Standard Wiring Diagram R(L1) S(L2) T(L3) Fus e/nfb(no Fuse B reaker) Recommended Circui t when power s uppl y is turned O FF by a fault output If the fault occ urs, the contact will be O N to turn off the power and protect the power sys tem. Factory setting: NPN Mode NPN Sw1 Fac tory setting PNP Please refer to Figur e 7 for w iring of NPN mode and PNP mode. Factory setting: ACI Mode AVI Sw2 ACI ACI/AVI sw itch When switching to AVI, it indicates AVI2 OFF FWD/Stop REV/Stop Multi-s tep 1 Multi-s tep 2 Multi-s tep 3 Multi-s tep 4 3 1 2 SA ON MC Digital Si gnal Common MC + R(L1) S(L2) T(L3) E RB RC +24V MI1 MI2 MI3 MI4 MI5 MI6 DCM E +10V Power supply +10V 20m A AVI Master Fr equency 0 to 10V 47K ACI /AVI2 4-20mA/0-10V ACM brake resi stor BR (opti onal) BUE brake unit (optional) - U(T1) V(T2) W(T3) E RA RB RC MO1 MCM AFM ACM E 8 1 Motor IM 3~ Multi-function c ontact output Refer to c hapter 2.4 for details. Fac tory setting is malfunction indication Fac tory setting: Driv e is in operation 48V50mA Max. Multi-function Photocoupler Output Analog Multi-func tion Output Terminal factory setti ng: Analog freq. / c urrent meter 0~1 0VDC/2 ma Analog S ignal common Fac tory setting: output frequency RS-485 serial inter face (NO T for VFD*E*C models) 1: Reserv ed 2: EV 3: G ND 4: SG - 5: SG + 6: Reserv ed 7: Reserv ed 8: EV For VFD*E*C models, please refer to figure 8. Main c irc ui t (power) terminals Control c ircuit terminals Shielded l eads & Cable It is recommended to install a circuit breaker at the control terminal to protect the circuit from an operation abnormality or sudden power outage. The protection circuit uses the multi-function output terminal of the AC motor drive for connection. When an abnormal condition (closed contact) occurs, the external power supply is disconnected to protect the power system of the AC motor drive. 3

External Parts Base frequency switch Motor stopping method switch Frequency source switch Digital keypad (optional) Mounting port for keypad Control board cover Control Terminals RS-485 Model Explanation VFD 007 E 23 A Product (Variable Frequency Drive) Version Type A: Standard drive C: CANopen Input Voltage 11: 115V Single-phase 21: 230V Single-phase E Series Applicable Motor Capacity 002: 0.25 HP(0.2 kw) 004: 0.5 HP(0.4 kw) 007: 1 HP(0.75 kw) 015: 2 HP(1.5 kw) P: Cold plate drive (frame A only) T: Frame A, built-in brake chopper 23: 230V 3-phase 43: 460V 3-phase 022: 3 HP(2.2 kw) 037: 5 HP(3.7 kw) 055: 7.5 HP(5.5 kw) 075: 10 HP(7.5 kw) 110: 15 HP(11 kw) 150: 20 HP(15 kw) 185: 25 HP(18.5 kw) 220: 30 HP(22 kw) 4

Application Fields Conveyor and Transportation Machinery Conveyor belt Automatic door Roller door Small elevator Escalator X-Y axis traveling crane Fan/Pump Equipment Building air conditioning system Wastewater processing system Constant pressure water treatment system Water treatment pump Agricultural pump Temperature control of mid and larger oven Air compressor Heat exchange fan Building water dispenser system Dryer's windmill Paper/Textile Machinery Round weaver Cross weaver Ribbon weaver Printing press Industrial sewing machine Knitting machine 5

Food Processing Dumpling making machine Food mixer Noodle making machine Wood Working Machinery 4 side planer Wood carving machine Woodworking machine Simple cutting machine for wood working Spraying machine Machine Tool/Metal Processing Machinery Grinding machine Drilling machine Small lathe Milling machine Injection molding (clamp) Others Ironing machine Pulverizer Treadmill Feeder Industrial washing machine Car washing machine Packing machine Centrifuge Liquid mixing machine 6

Specifications 115V Output Rating Output Rating Input Rating Output Rating Input Rating 230V 460V Input Rating Voltage Class 115 V Model Number VFD- E 002 004 007 Max. Applicable Motor Output (kw) 0.2 0.4 0.75 Max. Applicable Motor Output (hp) 0.25 0.5 1.0 Rated Output Capacity (kva) 0.6 1.0 1.6 Rated Output Current (A) 1.6 2.5 4.2 Maximum Output Voltage (V) 3-phase proportional to twice the input voltage Output Frequency (Hz) 0.1 ~ 599 Hz Carrier Frequency (khz) 1-15 Rated Input Current (A) Single-phase 6 9 18 Rated Voltage/Frequency Single-phase 100-120 V, 50 / 60 Hz Voltage Tolerance ±10% (90-132 V) Frequency Tolerance ±5% (47-63 Hz) Cooling Method Natural cooling Fan cooling Weight (kg) 1.2 1.2 1.2 Voltage Class 230 V Model Number VFD- E 002 004 007 015 022 037 055 075 110 150 Max. Applicable Motor Output (kw) 0.2 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 Max. Applicable Motor Output (hp) 0.25 0.5 1.0 2.0 3.0 5.0 7.5 10 15 20 Rated Output Capacity (kva) 0.6 1.0 1.6 2.9 4.2 6.5 9.5 12.5 17.1 25 Rated Output Current (A) 1.6 2.5 4.2 7.5 11 17 25 33 45 65 Maximum Output Voltage (V) 3-phase proportional to twice the input voltage Output Frequency (Hz) 0.1 ~ 599 Hz Carrier Frequency (khz) 1-15 Rated Input Current (A) Single / 3-phase 3-phase 4.9 / 1.9 6.5 / 2.7 9.7 / 5.1 15.7 / 9 24 / 15 20.6 26 34 48 70 Rated Voltage/Frequency Single / 3-phase, 200-240 V, 50 / 60 Hz 3-phase, 200-240 V, 50 / 60 Hz Voltage Tolerance ±10% (180-264 V) Frequency Tolerance ±5% (47-63 Hz) Cooling Method Natural cooling Fan cooling Weight (kg) 1.1 1.1 1.1 1.9 1.9 1.9 3.5 3.5 3.57 6.6 Voltage Class 460 V Model Number VFD- E 004 007 015 022 037 055 075 110 150 185 220 Max. Applicable Motor Output (kw) 0.4 0.75 1.5 2.2 3.7 5.5 7.5 11 15 18.5 22 Max. Applicable Motor Output (hp) 0.5 1.0 2.0 3.0 5.0 7.5 10 15 20 25 30 Rated Output Capacity (kva) 1.2 2.0 3.3 4.4 6.8 9.9 13.7 18.3 24 29 34 Rated Output Current (A) 1.5 2.5 4.2 5.5 8.5 13 18 24 32 38 45 Maximum Output Voltage (V) 3-phase proportional to input voltage Output Frequency (Hz) 0.1 ~ 599 Hz Carrier Frequency (khz) 1-15 3-phase Rated Input Current (A) 1.9 3.2 4.3 7.1 11.2 14 19 26 35 41 49 Rated Voltage/Frequency 3-phase, 380-480 V, 50 / 60 Hz Voltage Tolerance ±10% (342-528 V) Frequency Tolerance ±5% (47-63 Hz) Cooling Method Natural cooling Fan cooling Weight (kg) 1.2 1.2 1.2 1.9 1.9 4.2 4.2 4.2 7.47 7.47 7.47 7

Control Characteristics Operating Characteristics Environmental Conditions Control System Frequency Setting Resolution Output Frequency Resolution Torque Characteristics Overload Endurance Skip Frequency Accel/Decel Time Stall Prevention Level DC Braking Regenerated Braking Torque SPWM (Sinusoidal Pulse Width Modulation) Control (V/F or sensorless vector control) 0.01 Hz 0.01 Hz Including the auto-torque/auto-slip compensation; starting torque can be 150% at 3.0 Hz 150% of rated current for 1 minute Three zones, setting range 0.1 ~ 599 Hz 0.1 to 600 seconds (2 Independent setting of Accel/Decel time) Setting 20 to 250% of rated current Operation frequency 0.1 ~ 599.0 Hz, output 0~100% rated current Start time 0~60 seconds, stop time 0~60 seconds Approx. 20% (up to 125% possible with optional brake resistor or externally mounted brake unit, 1-15hp models (built-in brake chopper)) V/F Pattem Adjustable V/F pattern Keypad Setting by Frequency Setting Potentiometer 5 kω / 0.5 W, 0 to +10 VDC, 4 to 20 ma,rs-485 interface; External Signal Multi-function Inputs 3 to 9 (15 steps, Jog, up/down) Operation Keypad Set by RUN and STOP Setting 2 wires / 3 wires (MI1, MI2, MI3), JOG operation, RS-485 serial interface (MODBUS), Signal External Signal programmable logic controller Multi-step selection 0 to 15, Jog, accel/decel inhibit, 2 accel/decel switches, counter, external Multi-function Input Signal Base Block (NC, NO), auxiliary motor control is invalid, ACI / AVI / AUI selections, driver reset, UP/DOWN key settings, sink/source (=NPN / PNP) selection AC drive operating, frequency attained, non-zero frequency, Base Block, fault indication, Multi-function Output Indication local/remote indication, auxiliary motor output, drive is ready, overheat alarm, emergency stop and status selections of input terminals (NC / NO) Analog Output Signal Output frequency/current Alarm Output Contact Contact will be On when drive malfunctions (1 Form C/change-over contact or 1 open collector output) Built-in PLC, AVR, accel / decel S-Curve, over-voltage / over-current stall prevention, 5 fault records, reverse inhibition, momentary power loss restart, DC braking, auto torque/slip compensation, auto tuning, adjustable carrier frequency, output frequency limits, parameter Operation Functions lock/reset, vector control, PID control, external counter, MODBUS communication, abnormal reset, abnormal re-start, power-saving, sleep/wake function, fan control, 1st / 2nd frequency source selections, 1st / 2nd frequency source combination, NPN / PNP selection Over voltage, over current, under voltage, under current, external fault, overload, Protection Functions ground fault, overheating, electronic thermal, IGBT short circuit, PTC, instantly stop and then reboot (up to 20 sec by setting parameter) 6-key, 7-segment LED with 4-digit, 5 status LED, master frequency, output Display Keypad frequency, output current, custom units, parameter values for setup and lock, faults, RUN, STOP, RESET, FWD / REV Built-in EMC Filter For 230 V 1-phase and 460 V 3-phase models Enclosure Rating IP20 Pollution Degree 2 Installation Location Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust Ambient Temperature -10 ºC to + 50 ºC (40 ºC for side-by-side mounting) Non-Condensing and not frozen Storage/Transportation Temperature -20 ºC to 60 ºC Ambient Humidity Below 90% RH (non-condensing) Vibration 10 Hz f 57 Hz Fix Amplitude: 0.075 mm, 57 Hz f 150 Hz Fix Acceleration: 1 G (According to IEC 60068-2-6) Certifications 8

Dimensions Frame A1 MODEL VFD002E11A/11C/11T VFD002E21A/21C/21T VFD002E23A/23C/23T VFD004E11A/11C/11T VFD004E21A/21C/21T VFD004E23A/23C/23T VFD004E43A/43C/43T VFD007E23A/23C/23T VFD007E43A/43C/43T Unit: mm[inch] Frame W W1 H H1 D D1 D2 S1 S2 A1 mm 72.0 60.0 142.0 120.0 152.0 50.0 4.5 5.2 5.2 inch 2.83 2.36 5.59 4.72 5.98 1.97 0.18 0.20 0.20 Frame A2 W W1 D D1 D2 H H1 MODEL VFD015E23A/23C/23T VFD015E43A/43C/43T Unit: mm[inch] Frame W DIMENSIONAL W1 H H1 D UNIT:mm[inch] D1 D2 S1 S2 A2 mm 72.0 60.0 142.0 120.0 152.0 50.0 4.5 5.2 5.2 W W1 H H1 D D1 D2 S1 S2 inch 2.83 A2 72.0[2.83] 2.36 60.0[2.36] 5.59 142.0[5.59] 120.0[4.72] 4.72 152.0[5.98] 50.0[1.97] 5.98 4.5[0.18] 1.97 5.2[0.20] 5.2[0.20] 0.18 0.20 0.20 S1 S2 9

Frame A3 W W1 D D1 H1 H MODEL VFD002E11P/21P/23P S1 VFD004E11P/21P/23P/43P VFD007E21P/23P/43P VFD015E23P/43P Unit: mm[inch] Frame W W1 H H1 D D1 S1 A3 mm 72.0 56.0 155.0 143.0 111.5 9.5 5.3 inch 2.83 2.20 6.10 5.63 4.39 0.37 0.21 Frame B MODEL VFD007E11A/11C VFD015E21A/21C VFD022E21A/21C VFD022E23A/23C VFD022E43A/43C VFD037E23A/23C VFD037E43A/43C Unit: mm[inch] Frame W H D W1 H1 D1 D2 S1 S2 B mm 100.0 174.0 152.0 89.0 162.0 50.0 4.0 5.5 5.5 inch 3.94 6.86 5.98 3.50 6.86 1.97 0.16 0.22 0.22 10

Frame C MODEL VFD055E23A/23C VFD055E43A/43C VDF075E23A/23C VDF075E43A/43C VFD110E23A/23C VFD110E43A/43C Unit: mm[inch] Frame W H D W1 H1 D1 D2 S1 S2 C mm 130.0 260.0 169.2 116.0 246.5 78.5 8.0 6.5 5.5 inch 5.12 10.24 6.66 4.57 9.70 3.09 0.31 0.26 0.22 Frame D MODEL VFD150E23A/23C VFD150E43A/43C VFD185E43A/43C VFD220E43A/43C Unit: mm[inch] Frame W H D W1 H1 D1 D2 S1 S2 D mm 200.0 310.0 190.0 180.0 290.0 92.0 10.0 10.0 9.0 inch 7.87 12.20 7.48 7.09 11.42 3.62 0.39 0.39 0.35 11

Accessories Option Cards EME-R3AA Relay card (3 form A/ NO contacts) EME-R2CA Relay card (2 form C/Change-over contacts) EME-A1D3A Anglog I/O Card (12 bits) EME-A22A Anglog I/O Card (12 bits) EME-PG01 PG card CME-USB01 Second communication card (USB1.1) EME-D33A I/O card (photocoupler 3in + 3out) EME-D611A Multi-function Input Terminal MI1~MI6-COM Card (For Internal Installation) EME-D611B Multi-function Input Terminal MI1~MI6-COM Card (For External Installation) 12

Accessories Fieldbus Modules DeviceNet CME-DN01 PROFIBUS CME-PD01 CANopen CME-COP01 Others Brake Unit BUE-20015 BUE-40015 BUE-20037 BUE-40037 Keypad for Communication VFD-PU06 / KPC-CC01 DIN Rail (Width 35mm) MKE-DRA MKE-DRB Brake Resistor Zero Phase Reactor RF220X00A Grounding Plate MKE-EP Digital Keypad 13

Ordering Information VFD-E Series Frame Size Power Range Models Frame A1~A3 Frame A1: VFD002E11A/11C/11T VFD002E21A/21C/21T VFD002E23A/23C/23T VFD004E11A/11C/11T VFD004E21A/21C/21T VFD004E23A/23C/23T VFD004E43A/43C/43T VFD007E23A/23C/23T VFD007E43A/43C/43T 115 V: 0.2 kw ~ 0.4 kw 230 V: 0.2 kw ~ 1.5 kw 460 V: 0.4 kw ~ 1.5 kw Frame A2: VFD015E23A/23C/23T VFD015E43A/43C/43T Frame A3: VFD002E11P/21P/23P VFD004E11P/21P/23P/43P VFD007E21P/23P/43P VFD015E23P/43P Frame B 115 V: 0.75 kw 230 V: 1.5 kw ~ 3.7 kw 460 V: 2.2 kw ~ 3.7 kw VFD007E11A/11C VFD015E21A/21C VFD022E21A/21C VFD022E23A/23C VFD022E43A/43C VFD037E23A/23C VFD037E43A/43C Frame C 230 V: 5.5 kw ~ 11 kw 460 V: 5.5 kw ~ 11 kw VFD055E23A/23C VFD055E43A/43C VDF075E23A/23C VDF075E43A/43C VFD110E23A/23C VFD110E43A/43C Frame D 230 V: 15 kw 460 V: 15 kw ~ 22 kw VFD150E23A/23C VFD150E43A/43C VFD185E43A/43C VFD220E43A/43C 14

Industrial Automation Headquarters Delta Electronics, Inc. Taoyuan Technology Center 18 Xinglong Road, Taoyuan District, Taoyuan City 33068, Taiwan (R.O.C.) TEL: 886-3-362-6301 / FAX: 886-3-371-6301 Asia Delta Electronics (Jiangsu) Ltd. Wujiang Plant 3 1688 Jiangxing East Road, Wujiang Economic Development Zone Wujiang City, Jiang Su Province, P.R.C. 215200 TEL: 86-512-6340-3008 / FAX: 86-769-6340-7290 Delta Greentech (China) Co., Ltd. 238 Min-Xia Road, Pudong District, ShangHai, P.R.C. 201209 TEL: 86-21-58635678 / FAX: 86-21-58630003 Delta Electronics (Japan), Inc. Tokyo Office 2-1-14 Minato-ku Shibadaimon, Tokyo 105-0012, Japan TEL: 81-3-5733-1111 / FAX: 81-3-5733-1211 Delta Electronics (Korea), Inc. 1511, Byucksan Digital Valley 6-cha, Gasan-dong, Geumcheon-gu, Seoul, Korea, 153-704 TEL: 82-2-515-5303 / FAX: 82-2-515-5302 Delta Electronics Int l (S) Pte Ltd. 4 Kaki Bukit Ave 1, #05-05, Singapore 417939 TEL: 65-6747-5155 / FAX: 65-6744-9228 Delta Electronics (India) Pvt. Ltd. Plot No 43 Sector 35, HSIIDC Gurgaon, PIN 122001, Haryana, India TEL : 91-124-4874900 / FAX : 91-124-4874945 Americas Delta Products Corporation (USA) Raleigh Office P.O. Box 12173,5101 Davis Drive, Research Triangle Park, NC 27709, U.S.A. TEL: 1-919-767-3800 / FAX: 1-919-767-8080 Delta Greentech (Brasil) S.A. Sao Paulo Office Rua Itapeva, 26-3 andar Edificio Itapeva One-Bela Vista 01332-000-São Paulo-SP-Brazil TEL: 55 11 3568-3855 / FAX: 55 11 3568-3865 Europe Delta Electronics (Netherlands) B.V. Eindhoven Office De Witbogt 20, 5652 AG Eindhoven, The Netherlands TEL: +31 (0)40-8003800 / FAX: +31 (0)40-8003898 *We reserve the right to change the information in this catalogue without prior notice. DELTA_IA-MDS_VFD-E_C_EN_20161225