AC drive has detected too high a Check loading

Similar documents
TRIPS AND FAULT FINDING

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

RVS-DN Digital Reduced Voltage Motor Starter

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

620 Magnolia Avenue Suite B Ontario, CA (909) Diagnostic and Troubleshooting. Golf Cart. Revision: A Date:

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

MCW Application Notes 24 th August 2017

Errors with S1/S2/S3/S4 Safety cards

RVS-DX Digital Reduced Voltage Motor Starter

USERS MANUAL MCD REMOTE OPERATOR

MCD 500 Service Manual. Functional Tests 5 Power Circuit Test 5 Start Performance Test 5 Run Performance Test 6 Trip Messages 6 General Faults 10

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS?

SmartVFD HVAC FEATURES APPLICATION SPECIFICATION DATA

8 Troubleshooting and Maintenance

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

USER INSTRUCTION FOR PROGRAMMING INVERTER FUJI FRENIC LIFT

Variable speed drive or soft starter?

SYSDrive Frequency Inverter

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

ABB Softstarter Benefits Charnchanok Thongprad

VSD Series II Variable Speed Open Drives

VSD Series II Variable Speed Enclosed IntelliPass and IntelliDisconnect Drives

JC-VSD FP Series II Drives Product Bulletin 1

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

825-P Modular Protection System for motors Specification Guide

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

Quick Start Guide of CV50- ControlVIT Series

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Modulating Furnace Information. Warning on Meter Setting - Read First!

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

Service instructions. MAGNA Series 2000

Shenzhen Sine Electric Co., Ltd.

VSD Series II Variable Speed Micro Drives

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

Application Engineering Europe

Advanced Variable Torque Application Training Eaton Corporation. All rights reserved.

Overvoltage Suppression F7 Drive Software Technical Manual

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

CHAPTER 7 ERROR MESSAGE AND TROUBLESHOOTING

Combined Ventilation Controller RVWS-T-224HA

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

INVEOR "Smart connections." on five levels

Table of Contents. VLT 5000 Series Service Instructions. Introduction Product Overview Warnings and Cautions... 1


High performance Vector Control. Ratings. System configuration

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Frequency Inverters SJ Series Type P1

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

LG Air Conditioning Universal & Multi Split Fault Codes Sheet. Universal and Multi Split Units

IP 20/NEMA 1 & IP 66/NEMA 4X Compact Vector Control Drive

Kelly KDC Series/PM Motor Controller User s Manual

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

BRIVIS DUCTED INVERTER SERVICE MANUAL DRCi

UL/NEMA Type 1 & Type 12 FRENIC-HVAC Combination VFD

GRUNDFOS INSTRUCTIONS. Control HVAC. Installation and operating instructions. Other languages. net.grundfos.com/qr/i/

GS2 Series - Introduction

Axpert-CSS AMTECH DRIVES Axpert-CSS Amtech

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3.

Devices Supported: KEB48220 KEB48221 KEB48300 KEB48301 KEB48400 KEB48401 KEB48600 KEB48601 KEB72330 EB KEB72450 KEB EB KEB72600 KEB

MAKING MODERN LIVING POSSIBLE. Service Manual VLTp Soft Starter - MCD500 *MG17L402*

EcoNet and Flash Codes

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

Section 8. MAINTENANCE & TROUBLESHOOTING

5.1 Errors (Alarms) Error (alarm) definitions PROTECTIVE FUNCTIONS. (1) Major faults

PF3100 TROUBLESHOOTING SOLUTIONS TO COMMON PROBLEMS. v1.1 Revised Nov 29, 2016

Unidrive M700 Class leading performance with onboard real-time Ethernet

J1000. Compact Inverter Series.

Application example of a motor controlled by MCD100 and protected by a circuit breaker

Designed for ease of integration with automation systems

J1000 D E F I 1000 J1000 J1000 J1000 J1000

Quick Reference Guide. For NFX9000 Adjustable Frequency Drives. February 2006 NQ00. MN E February 2006

Low voltage AC drives

Delta Products VFD CP2000 Bypass Control Packages.

About this Troubleshooting Document

FKP-R/R2. User Guide for Pressure and Temperature controller with integrated pressure sensor

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Datasheet VFD-CP2000. Type number key A B C S -XY VFD 007 CP 43. Option cards. Slot 3

VFD E Series. Features

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

ATOTH-G Series BLDC Motor Controller. User s Manual

Start-up guide of LSLV-M100

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

ICON 2 1. FEATURES AND CHARACTEIRICS

RM B. Features. Drive Model Number Scheme. A RM6 Product Series

Subject Underhood G System Error Codes and Symptoms System or Parts affected

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

V1000. Inverter Series.

V1000 Inverter Series

Installation Instructions

MX1S Matrix Converter

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Continental Hydraulics Installation Manual CEM-AA-A

Visit for more technical information & downloads

SINAMICS GM150 IGCT version

Transcription:

Fault code Fault Name Fault type Default Possible Cause Remedy 1 Over Current Fault AC drive has detected too high a Check loading current (>4*IH) in the motor cable: Check motor Sudden heavy load increase Check cables and connections Short circuit in motor cables Make identification run 2 Over Voltage Fault Unsuitable motor The DC-link voltage has exceeded the limits defined: Too short a deceleration time Brake chopper is disabled High overvoltage spikes in supply Check ramp times Make deceleration time longer Use brake chopper or brake resistor (available as options) Activate overvoltage controller Check input voltage 3 Earth Fault Configurable Fault Start/Stop sequence too fast Current measurement has detected Check motor cables and that motor 5 Charging Switch Fault the sum of motor phase current is not zero: Insulation failure in cables or motor The charging switch is open, when the Reset the fault and restart START command has been given: distributor near to you 6 Emergency Stop Fault Faulty operation Component failure STO terminal open in control Closed STO terminal board Emergency signal from DI is activated Remove signal from DI 7 Saturation Trip Fault Short circuit in motor cables Check cables and connections IGBT module is damaged Reset the fault and restart verify that EMC screw is installed distributor near to you 9 UnderVoltage Configurable Fault DC link voltage is under the voltage In case of temporary limits defined: Most probable cause: Too low a supply voltage AC drive internal fault Defect input fuse External charge switch not closed supply voltage break reset the fault and restart the AC drive Check the supply voltage. If it is adequate, an internal failure has occurred. Contact the distributor near you Note: This fault is activated only if the drive is in Run state. 10 Input Phase Spv Configurable Fault Input line phase is missing Check supply voltage, fuses and cable 11 Output Phase Spv Configurable Fault Current measurement has detected that there is no current in one motor phase 12 BrakeChopperSpv Fault No brake resistor installed Brake resistor is broken Brake chopper failure 13 Drive UnderTemp Configurable Warning Too low temperature measured in power Check motor cable and motor Check brake resistor and cabling. If these are OK, the chopper is

14 Drive OverTemp Fault Unit s heat sink or board. Heat sink temperature is under 10 C Too high temperature measured in power Unit s heat sink or board. Heat sink temperature is over 90 C Check the correct amount and flow of cooling air Check the heat sink for dust Check the ambient temperature Make sure that the switching frequency is not too high in relation to ambient temperature and motor load 15 Motor Stalled Configurable No Action Motor is stalled Check motor and load 16 Motor OverTemp Configurable No Action Motor is too hot, based on either the drive s estimate or on temperature feedback Decrease motor load. If no motor overload exists, check the temperature model 17 Motor UnderLoad Configurable No Action Condition defined by parameter P1.9.15~P1.9.17 have been valid longer than the time defined by P1.9.18 parameters Check load 18 IP Address Conflict Configurable Warning IP setting issue. Check settings for IP address, verify no duplicates are on the network. 19 Power board EEPROM Fault Fault Power board eeprom fault, memory lost in eeprom. Cyle power to drive. Try updating software, if issue continues contact 20 FRAM Fault Fault FRAM data error in FRAM memory. Cycle power to drive. 21 Serial Flash Fault warning Serial flash error, serial flash memory failed. 25 MCU WatchDog Fault Fault Watchdog register overflows in MCU Cycle power to drive. Cycle power to drive. 26 Start-up Prevent Fault The time when Interlock signal activates is over setting time. 29 Thermistor Fault Configurable Fault Option board or control board thermistor resistor lager than 4.7K Stop drive and resend start command. Thermistor open or short, over temperature 32 Fan Cooling Fault Fan is damaged or stalled. Check fan and fan connected wires, verify 24Vdc is supplied to fan. 36 Compatibility Fault Fault The control board isn t match with the power board. Cycle power to drive. 37 Device Change Warning Power board or option card change. Alarm will reset 38 Device Added Warning Power board or option board added. Device is ready for use

39 Device Removed Fault Optional board removed from slot, or power board removed from control board. 40 Device Unknown Fault Unknown device connected (power board/option board) Old parameter settings will be used Device no longer available in drive. Check eeprom connection. Check board connection on slot A/B Power cycle to drive. 41 IGBT Temperature Fault 43 Encoder Fault Fault IGBT temperature is too high. Encoder 1 channel A is missing Encoder 1 channel B is missing Both encoder 1 channels are missing Encoder reversed Check output loading Check motor size Decrease switching frequency Check encoder connections Check encoder and encoder cable Check encoder board Check encoder frequency in open loop Encoder board missing 50 AIN<4mA(4to20mA) Configurable No Action Loss in analog input signal, dropped below 4mA. 51 External Fault Configurable Fault Digital input is activated for external fault input. 52 Keypad Communication Fault Configurable Fault The connection between the control keypad and frequency converter is broken, and The local reference is keypad reference or the local control place is keypad, and The keypad communication fault protection is not NO action Verify analog input current reference value on either AI1 or AI2, check cabling. check digital input settings and verify input level, could be an extrnal device causing fault. Check keypad connection and possible keypad cable. 54 OPT Card Fault Configurable Fault Defective option card or option card slot Check right option card and optoin card slot connections. Check Board Status on Keypad for exact cause of fault. Contact distributor nearest 55 Real time clock fault Configurable Warning Communication between MCU and Check the RTC chip, RTC chip isn t normal The power of RTC chip isn t normal power cycle to drive. If issue contines contact distributor near The real time isn t normal 56 PT100 Fault Configurable Fault Temperature is beyond the limit of sensing capacity of PT100 57 Motor ID fault Fault The Motor parameters Identification running was not completed successfully Pt100 short, open or over temperature, check PT100 temperature probe. Check motor size Verify the input and output wiring is connected properly.

58 Current Measure Fault Fault Current measurement is out of range 59 Possible power wiring error detfault power wiring connected to output of drive. 60 Control Board OverTemp Fault 61 Internal-ctrl Supply Fault +24V port voltage is over 27V or under 17V 62 Too Many Speed Search Restarts Fault Control board is over +85 degrees or under 30 degrees Speed searching failed when peforming flying start. Restart the drive again. distributor near to you Verify power input wiring is connected to L1, L2 and L3 terminals and they are properly torqued. Check NTC resistor Check control board temperature Check voltage range of +24V on terminals 12 to 13. If voltage is out of range contact distributor near Check motor parameters setting and motor connections. 63 Current Unbalance Fault Output current unballanced. Check motor wiring and voltage output of drive. If issue continues contact distributor near 64 Replace Battery Configurable Warning RTC Battery voltage is too low. Check the RTC battery voltage, contact distributor near you for replacement battery. 65 Replace Fan Configurable Warning Fan life is less than 2 months Check the fan, clean out any contamination, contact distributor near you for replacement fan. 66 Safety Torque Off Fault STO Triggered, STO input is open. Reset STO Trigger and verify wiring. Reset fault after input is enabled. 67 current limit control Warning 68 over voltage control Warning The output current has reached the current limit value The DC link voltage has reached its voltage limit value Check the load Set the acceleration time longer Check the input voltage Set the acceleration/deceleratio n time longer 69 System Fault Fault thermistor spi communication error. check thermistor chip. 70 System Fault Fault MCU send wrong parameters to DSP Restart the drive again. distributor near to 71 System Fault Fault MCU and DSP communication error. Restart the drive again. distributor near to 72 Power Board EEPROM Fault Fault Power board eeprom fault, memory lost in eeprom when initial drive. Cyle power to drive. Try updating software, if issue continues contact

73 FRAM Fault Fault fram chip is broken. contact Distributor near 74 FRAM Fault Fault crc check fault when acess fram data Try recovery factory default setting if issue continues contact 75 Power Board EEPROM Fault Fault eeprom chipor I2c circuit is brokencontact Distributor near 76 Power Board EEPROM Fault Fault crc check fault when acess eeprom data. Try recovery factory default setting if issue continues contact 77 Serial Flash Fault warning external serial flash chip is broken. contact Distributor near 82 BypassOverLoad Fault Over load when motor is in bypass mode Check motor connection situation 83 FieldBus Fault Configurable Fault Loss of communication with Modbus RTU, and The fieldbus Check RS485 reference is the remote reference or Verify drive parameter The fieldbus control place is the remote control place,and the fault protection is not NO action are set correctly. Check master programming to verify proper addressing. 84 FieldBus Fault Configurable Fault Loss of communication with Modbus TCP,and The fieldbus Check Ethernet reference is the remote reference or Verify drive parameter The fieldbus control place is the are set correctly. Check remote control place,and The fault master programming to protection is not NO action verify proper addressing. 85 FieldBus Fault Configurable Fault Loss of communication with BACnet, and The fieldbus reference is the remote reference Check RS485 Verify drive parameter OR The fieldbus control place is the are set correctly. Check remote control place,and The fault BACnet master protection is not NO action configuration 86 FieldBus Fault Configurable Fault Loss of communication with Ethernet IP, and The fieldbus reference is the remote reference Check Ethernet Verify drive parameter OR The fieldbus control place is the are set correctly. Check remote control place,and The fault EIP master protection is not NO action configuration 87 FieldBus Fault Configurable Fault Loss of communication with Profibus master on Slot A, and The fieldbus reference is the remote reference OR The fieldbus control place is the remote control place,and The fault protection is not NO action Check cenet communication wiring. Verify drive parameter are set correctly. Check cenet master configuration

88 FieldBus Fault Configurable Fault Loss of communication with Profibus master on Slot B, and The fieldbus reference is the remote reference OR The fieldbus control place is the remote control place,and The fault protection is not NO action 89 Under Voltage Fault The DC link voltage has reached the Drive under voltage stop limit value. 90 Drive UnderTemp Warning/Fault Cold weather mode is not enabled, and unit temperature is less than -10 degree. Cold weather mode is enabled and Under Temp Fault Override is not set, unit temperature is less than -30 degree. Cold weather mode is enabled and Under Temp Fault Override is not set, unit temperature is -20~ -30 degree. The temp <-20 degree when cold weather start time out. Check cenet communication wiring. Verify drive parameter are set correctly. Check cenet master configuration Check the input voltage. If unit temp -20 ~ -10 degree, start motor in cold weather mode. If unit temp <-20 degree, Warm up unit above - 20deg C for proper operation using cold weather mode.if still < - 20 degree when cold weather mode time out, try higher output voltage in cold weather mode. 91 Option Card Fault Fault External supply on the DeviceNet communication connector is not present. Check voltage and wiring of power supply of the DeviceNet communication.