PSNH INTERCONNECTION REQUEST

Similar documents
Legal Name of the Customer (or, if an individual, individual's name): Name: Contact Person: Mailing Address: Physical Address: City: State: Zip Code:

NORTH CAROLINA INTERCONNECTION REQUEST APPLICATION FORM. Utility: Duke Energy Progress

Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 25 kw to 10 MVA or less)

Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kva to 10 MVA or less)

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

Maryland Level 2, Level 3 & Level 4 Interconnection Request Application Form (Greater than 10 kw to 10 MW or less)

GENERATOR INTERCONNECTION APPLICATION

CATEGORY 2 GENERATOR INTERCONNECTION APPLICATION

Electric Utility Contact Information Indiana Michigan Power

CUSTOMER / ACCOUNT INFORMATION Electric Utility Customer Information (As shown on utility bill)

RULE 21 GENERATING FACILITY INTERCONNECTION APPLICATION SMUD s Distribution System - (SMUD FORM 2655)

If any further information is required for CHELCO to fulfill its reporting requirements, please let us know.

Request for Payment Instructions Wholesale Distribution Access Tariff (WDAT) Attachment I - GIP

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 25 kw)

Rider : NET METERING SERVICE AND ELECTRICAL SYSTEM INTEGRATION

Request for Payment Instructions Rule 21 Export Submittal Instructions

GENERATING FACILITY INTERCONNECTION APPLICATION. Part 1 Introduction and Overview

Section 6. Generation Interconnection

GENERATING FACILITY INTERCONNECTION APPLICATION. Part 1 Introduction and Overview

Application for Interconnection and Net Metering Revision: 1 Revised: November 7, 2017

Request for Payment Instructions form. Rule 21 Non-Exporting Generators Submittal Instructions

Please Refer to Attached Sample Form

Form C Renewable Energy Micro-Generation Connection Application Distribution System

Request for Payment Instructions Rule 21 Non-Exporting Generators Submittal Instructions

TERMS AND CONDITIONS

APPLICATION ELECTRICITY SERVICES. APPLICATION FOR THE CONNECTION OF SMALL SCALE EMBEDDED GENERATION Page 1

Southern Company Interconnection Process. Dexter Lewis Research Engineer Research and Technology Management

Interconnection Process for Customer-Owned Generation (QFs)

Please Refer to Attached Sample Form

Micro-Generation Connection Application For Connection of Micro-Generation Facilities of 10 kw

A member-consumer with a QF facility shall not participate in the Cooperative s electric heat rate program.

INTERCONNECTION RULES AND REGULATIONS FOR NET ENERGY METERING SYTEMS

August 2, 2001 PUBLIC UTILITIES COMMISSION OF THE STATE OF CALIFORNIA ENERGY DIVISION

INTERCONNECTION STANDARDS FOR CUSTOMER-OWNED GENERATING FACILITIES 25 kw OR LESS PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

White River Electric Association, Inc. Net Metering Information & Service Requirements

Definitions. Scope. Customer Generation Interconnection Requirements

Spec Information. Reactances Per Unit Ohms

Form G5-1 PACIFIC GAS AND ELECTRIC COMPANY GENERATION PRE-PARALLEL INSPECTION

Municipality Generator Interconnection Application Single Meter Application Part I

Net Metering Service. Customer Information Package

SOUTH HADLEY ELECTRIC LIGHT DEPARTMENT Net Metering Policy As Amended 03/23/16 By the South Hadley Municipal Light Board

PJM Generator Interconnection Request Queue #R60 Robison Park-Convoy 345kV Impact Study September 2008

TECHNICAL TERMS AND ABBREVIATIONS

Instructions for Completing Oncor s Interconnection Application For Solar PV Projects

CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems

Distributed Generation Interconnection Policy

GENERATOR DATA MAY 10, 2018

CHAPTER 5 FAULT AND HARMONIC ANALYSIS USING PV ARRAY BASED STATCOM

Connection of Power Generating Modules to DNO Distribution Networks in accordance with EREC G99

Application for Commission Approval to Construct a Generating Station Pursuant to Public Utilities Article Section and

GENERATOR DATA SEPTEMBER 29, 2015

Louisville Gas and Electric Company

New Hampshire Electric Cooperative (NHEC) Introduction to Net Metering

REQUIREMENTS FOR PARALLEL OPERATION FOR CUSTOMERS WITH GENERATION NOT EXCEEDING 50 kw

INTERCONNECTION STANDARDS FOR PARALLEL OPERATION OF SMALL-SIZE GENERATING FACILITIES KILOWATTS IN THE STATE OF NEW JERSEY

34 th Hands-On Relay School

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

MCCOOK PUBLIC POWER DISTRICT McCook, Nebraska BOARD POLICY NUMBER 488

California PUC Rule 21 Generating. Facility Interconnection Application Guide. Technical Note

DISTRIBUTED RESOURCE GENERATION Feed-In-Tariff Single Phase

Please Refer to Attached Sample Form

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018

Connection of Power Generating Modules to DNO Distribution Networks in accordance with EREC G99

Enquiry Form (Non-Registered Generator With Capacity less than 5 MW)

Northeastern Rural Electric Membership Corporation Schedule DG-2 Columbia City, Indiana Page 1 of 5

SCHEDULE NO. ACG33 NET METERING SERVICE

Louisiana Net Metering Service. Customer Information Package

Noble County Rural Electric Membership Corporation

Net Metering Interconnection Requirements

APPLICATION Net Energy Metering Interconnection For Solar And/Or Wind Electric Generating Facilities Of 30 Kilowatts Or Less

Summary of General Technical Requirements for the Interconnection of Distributed Generation (DG) to PG&E s Distribution System

Rate Schedules. Effective 1/1/2019

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 RULE NO. 17 NET ENERGY METERING

Bulletin Interconnection of electric power production sources Rules 2-010, , , , , , and

CHAPTER 25. SUBSTANTIVE RULES APPLICABLE TO ELECTRIC SERVICE PROVIDERS.

APPLICATION FOR INSTALLATION OF SMALL SCALE EMBEDDED ELECTRICITY GENERATION

Lesson 16: Asynchronous Generators/Induction Generators

HCI 534E/544E - Technical Data Sheet

HCI 434E/444E - Technical Data Sheet

Columbia Water & Light Interconnection & Net Metering Agreement Electrical Facility

Oncor Application for Interconnection of Distributed Generation

Enquiry Form for Micro and Small Generators 5MW and Less

Application for Operation of & Net Metering for Member-Owned Generation Name: Mailing Address: City: County: State: Zip Code: _

Net Metering Interconnection Requirements. Customer Generation Capacity Not Exceeding 100 kw. Date: Version: 1

Renewable Energy Systems 14

TECHNICAL SPECIFICATION FOR INDEPENDENT POWER PRODUCERS. NB Power Customer Service and Distribution. June 2008

UCDI224F - Technical Data Sheet

UCI224F - Technical Data Sheet

UCI224C - Technical Data Sheet

UCI274D - Technical Data Sheet

Customer Name : Account Number: Customer Service Address (Street, City, State, ZIP Code): Customer Mailing Address: Customer Telephone Number:

UCDI274J - Technical Data Sheet

UCDI274K - Technical Data Sheet

UCI274D - Technical Data Sheet

UCI274H - Technical Data Sheet

UCI274G - Technical Data Sheet

EASTERN ILLINI ELECTRIC COOPERATIVE REGULATION NO. 26A

UCDI274K - Technical Data Sheet

UCDI224E - Technical Data Sheet

Transcription:

PSNH INTERCONNECTION REQUEST Send the completed Interconnection Request and required attachments to: Public Service of New Hampshire Attn: Michael Motta, Senior Engineer Supplemental Energy Sources P. O. Box 330 Manchester, NH 03105 Telephone Number: 603-634-2920 Fax: 603-634-2924 E-Mail Address: Michael.Motta@nu.com An Interconnection Request is considered complete when it provides all applicable and correct information required below. Documentation that the applicant has control of the property on which the proposed facility shall be located must be submitted with the Interconnection Request. The documentation may include proof of ownership, a leasehold interest, a right to develop, or an option to acquire the site. A site electrical one-line diagram showing the configuration of the Generating Facility equipment, current and potential circuits, and protection control schemes. The one-line diagram must be signed and stamped by a licensed Professional Engineer. Interconnection Customer Information: Legal Name of the Interconnection Customer (or, if an individual, individual's name) Name: Contact Person: Mailing Address: City: State: Zip: Facility Location (if different from above): Telephone (Day): Telephone (Evening): Fax: E-Mail Address: 1

Interconnection Customer Information: Alternative Contact Information (if different from the Interconnection Customer) Name: Contact Person: Mailing Address: City: State: Zip: Facility Location (if different from above): Telephone (Day): Telephone (Evening): Fax: E-Mail Address: Is the Interconnection Request for: New Generating Facility? Capacity addition to or Material Modification of an existing Generating Facility: If capacity addition or Material Modification of an existing facility, please describe: Commencement of participation in the wholesale markets by an existing Generating Facility: A retail customer interconnecting a New Generating Facility that will produce electric energy to be consumed only on the retail customer s site? If onsite use of power, describe the mode of operation: (Please Check all that Apply) Peak Shaving Demand Management Primary Power/Base Load Combined Heat and Power or Cogeneration 2

Stand By/Emergency/Back-up Net Metering If Net Metering, does the Generating Facility meet the requirements for eligibility as defined in Puc 902.01 for a Combined Heat and Power System and/or Puc 902.02 for a Customer-Generator of Chapter Puc 900 Net Metering for Customer Owned Renewable Energy Generation Resources of 1000 Kilowatts or Less. Puc 902.01 Combined heat and power system means a combined heat and power system as defined on RSA 321-A:1-a, II-d, namely a new system installed after July 1, 2011, that produces heat and electricity from one fuel input using an eligible fuel, without restriction to generating technology, has an electric generating capacity rating of at least one kilowatt and not more than 30 kilowatts and a fuel system efficiency of not less than 80 percent in the production of heat and electricity, or has an electric generating capacity greater than 30 kilowatts and not more than one megawatt and a fuel system efficiency of not less than 65 percent in the production of heat and electricity. Fuel system efficiency shall be measured as a usable thermal and electrical output in BTU s divided by fuel input in BTU s. Puc 902.02 Customer-generator means eligible customer-generator as defined in RSA 362-A:1-a, IIb, namely an electric utility customer who owns or operates an electrical generating facility either powered by renewable energy or which employs a heat led combined heat and power system, with a total peak generating capacity of not more than 100 kilowatts, or that first began operation after July 1, 2010 and has a total peak generating capacity of 100 kilowatts or more up to one megawatt, that is located behind a retail meter on the customer s premises, is interconnected and operates in parallel with the electric grid, and is used in the first instance to offset the customer s own electricity requirements. Interconnection Customer Signature Date A Qualifying Facility where 100% of the output will be sold to PSNH? A Qualifying Facility intending to sell power at wholesale to an entity other than PSNH? A Generator interconnecting a new Generating Facility that plans to participate in the wholesale markets? 3

An existing Generating Facility commencing participation in the wholesale markets? Paralleling: Will the Generating Facility operate in parallel with the PSNH system for any amount of time? If No: Then Generator is operating as Open Transition. If Yes: Will the Generating Facility operate in parallel with PSNH for longer than 100 milliseconds? If No: Then Generator is operating as Closed Transition. If Yes: Then Generator is operating as Parallel Operation. Will the generator operation vary by season? (Please describe) For installations at locations with existing electric service to which the proposed Generating Facility will interconnect, provide: Account # Energy Service Provider (if other than PSNH) Meter # Contact Name: Title: Address: Telephone (Day): Telephone (Evening): Fax: E-Mail Address: Requested Point of Interconnection: Generating Facility's Requested In-Service Date: 4

Generating Facility Information: Data apply only to the Generating Facility, not the Interconnection Facilities. Energy Source: Solar Wind Hydro Hydro Type (e.g. Run-of-River): Diesel Natural Gas Fuel Oil Other (state type) Prime Mover: Fuel Cell Reciprocating Engine Gas Turbine Steam Turbine Micro-turbine PV Other (state type) Type of Generator: Synchronous Induction Inverter Generator Manufacturer: Generator Model Name & Number: Generator Version Number: Generator Nameplate Rating: kw (Typical) For Inverter-based machines the kw rating of the inverter, and for all other interconnections the kw rating of the generation unit. Generator Nameplate kvar: Generating Facility or Customer-Site Load: kw (if none, so state) Typical Reactive Load (if known): Maximum Physical Export Capability Requested: kw Generator Nameplate Output Power Rating in kw: (Summer) (Winter) Generator Nameplate Output Power Rating in kva: (Summer) (Winter) Individual Generator Power Factor: Rated Power Factor: Leading Lagging Generating Facility Characteristic Data (for inverter-based machines): Inverter Manufacturer: Model Name & Number: Is the Inverter UL 1741 listed? 5

Is the Inverter IEEE 1547 listed? Is the Inverter IEEE 1547.1 listed? Max design fault contribution current: Instantaneous or RMS? Harmonics Characteristics: Start-up requirements: Available fault current: Wind Farm Interconnection: Total Number of Generators in wind farm to be interconnected pursuant to this Interconnection Request: Quantity: Elevation: Single Phase Three Phase Generating Facility Characteristic Data (for rotating machines): Speed: RPM Neutral Grounding Resistor (If Applicable): Synchronous Generators: Direct Axis Synchronous Reactance, Xd: Per Unit Direct Axis Transient Reactance, X d : Per Unit Direct Axis Sub transient Reactance, X d : Per Unit Negative Sequence Reactance, X 2 : Per Unit Zero Sequence Reactance, X 0 : Per Unit KVA Base: Field Volts: Field Amperes: Induction Generators: Motoring Power (kw): I 22 t or K (Heating Time Constant): Rotor Resistance, Rr: Per Unit Stator Resistance, Rs: Per Unit Stator Reactance, Xs: Per Unit 6

Rotor Reactance, Xr: Per Unit Magnetizing Reactance, Xm: Per Unit Short Circuit Reactance, Xd'': Per Unit Exciting Current: Amps Temperature Rise: Frame Size: Design Letter: Reactive Power Required In Vars (No Load): Reactive Power Required In Vars (Full Load): Total Rotating Inertia, H: Per Unit on kva Base Transformer Data (If Applicable, for Generating Facility-Owned Transformer): Transformer Size: kva Is the transformer: single phase three phase? Transformer Impedance: % on kva Base Transformer Positive-Sequence Short Circuit Impedances (pu): Zps=, Zpt=, Zst= Transformer Zero-Sequence Impedances (pu): Zpm0=, Zsm0=, Zmg0= Transformer Neutral Grounding Reactor/Resistor Impedance (Ohms): Transformer BIL Rating kv If Three Phase: Transformer Primary: Volts Delta Wye Wye Grounded Transformer Secondary: Volts Delta Wye Wye Grounded Transformer Tertiary: Volts Delta Wye Wye Grounded Transformer Fuse Data (If Applicable, for Generating Facility-Owned Fuse): (Attach copy of fuse manufacturer's Minimum Melt and Total Clearing Time-Current Curves) Manufacturer: Type: Size: Speed: 7

Interconnecting Circuit Breaker (if applicable): Type: Load Rating (Amps): Interrupting Rating (Amps): Trip Speed (Cycles): Current Transformer Data (If Applicable): (Enclose Copy of Manufacturer's Excitation and Ratio Correction Curves) Type: Accuracy Class: Proposed Ratio Connection: Type: Accuracy Class: Proposed Ratio Connection: Potential Transformer Data (If Applicable): Type: Accuracy Class: Proposed Ratio Connection: Type: Accuracy Class: Proposed Ratio Connection: General Information: Is evidence of site control enclosed? Are site electrical One-Line Diagram(s) showing the configuration of all Generating Facility equipment enclosed? Enclose copy of any site documentation that indicates the precise physical location of the proposed Generating Facility (e.g., USGS topographic map or other diagram or documentation). Enclose copy of any site documentation that describes and details the operation of the protection and control schemes. 8

Applicant Signature I hereby certify that, to the best of my knowledge, all the information provided in this Interconnection Request is true and correct. Interconnection Customer: Date: 9