MM501U. User s Manual. SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors

Similar documents
C1XP Series. Models: C1XP01-115AC C1XP03-115AC C1XP03-D240AC USER MANUAL

DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED.

Model A Switching Logic Board. User s Manual. For Use With Minarik Full-Wave Regenerative Drives

SCR THYRISTOR MOTOR CONTROLS , , , , , , M , M , M OPERATION MANUAL

17429X.00 SERIES MODELS:

SPEEDMASTER. Operation Manual & NEMA 4X SCR MOTOR CONTROLS

Models: User s Manual. Pulse-Width Modulated, Adjustable Speed Drives for DC Brush Motors

User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

MM03-PCM MM10-PCM. User s Manual. SCR, Adjustable Speed Drives for DC Brush Motors

XP Series USER MANUAL PCMXP02-115AC PCMXP05-115AC PCMXP10-115AC XP02-115AC XP02-115AC-Q XP05-115AC XP10-115AC.

PWP Series USER MANUAL PWP100-2 PWP100-2-QDT PWP100-5 PWP PWP101-2 PWP101-5 PWP

MHS Series USER MANUAL MHS MHS MHS MHS443-10

MM23xx1C Series USER MANUAL MM23001C MM23001C-Q MM23011C MM23011C-Q MM23101C MM23111C MM23201C MM23211C MM23401C MM23411C.

Excel [XL] Series USER S MANUAL

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

An American Control Electronics Brand. RG6xU SERIES USER MANUAL RG60U RG61U.

An American Control Electronics Brand RG500 SERIES USER MANUAL RG500UA RG500UA-PCM RG500A RG510UA RG510UA-PCM RG510A.

VFD Series USER MANUAL VFD02-115AC VFD02-230AC VFD02-D230AC VFD04-115AC VFD04-230AC VFD04-D230AC.

DC3E Non-Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC M/N DC3N-12D AI M/N DC3N-12D-4X-010-AI

USER S MANUAL

USER S MANUAL. Variable-frequency drives for 3-phase and single-phase AC motors

USER S MANUAL VFD05-D230-PCM VFDP4X04-D230-PCM VFDA4X04-D230-PCM VFDF4X04-D230-PCM VFDS4X05-D230-PCM

User s Manual MMVFD SERIES MODEL: MMVFD06-D230AC. Variable-frequency drives for 3-phase AC motors

RG500 SERIES USER S MANUAL. SCR, Dual Voltage, Adjustable-Speed Regenerative Drives for DC Brush Motors

DC3R Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC

USER S MANUAL VFD SERIES. Variable-frequency drives for 3-phase and single-phase AC motors

USER S MANUAL. Variable-frequency drive for 3-phase and single-phase AC motors

DC3RD Digital Regenerative DC Drive User Guide 1/4 to 2 HP, 115/230 VAC. Instruction Manual D2-3455

Graham. Vari Speed S1000 Instruction Manual. TRANSMISSIONS, Inc. Installation, Operation and Maintenance Manual

Boston Gear Ratiotrol DC Motor Speed Control

Boston Gear Ratiotrol DC Motor Speed Control

Filtered PWM Speed Control for Permanent Magnet DC Motors

WDC CONTROL SERIES. Instruction Manual. Variable Speed DC Control

CONTROL FEATURES AVAILABLE OPTIONS

SAFTRONICS DF8 PLUS SERIES

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE MODEL KBRG-255 (5HP) KB Part No FULL WAVE 4 QUADRANT FWD ACCEL REV ACCEL FWD CL

Boston Gear Ratiotrol DC Motor Speed Control

KBWS WHISPER DRIVE PULSE WIDTH MODULATED (PWM)

BC141, BC142, BC142-5 & BC142-6 DC Control

Installation and Operation Manual. *See page 6 for CE Information

Installation and Operating Manual

INSTALLATION AND OPERATING INSTRUCTIONS REGENERATIVE DRIVE FULL WAVE 4 QUADRANT REV S/LT NLT R33 AC LINE FUSE ARMATURE F2 FUSE TB2

RCP200 Series Motor Controls. Instruction Manual Model RCP Model RCP Model RCP202-BC1 Model RCP202-BC2 Model RCP205-BC2

DUAL SWIVEL REEL OPERATING INSTRUCTIONS


BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

MDC VAC, 15A Brushless Controller. User s Guide. 910 East Orangefair Lane, Anaheim, CA

Installation & Operation Manual

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

KBIC SCR DC Motor Speed Controls

Dayton DC Motor Control

TABLE OF CONTENTS STANDARD FEATURES

BLDPN30001 Series. 30A Brushless DC Controller. User s Guide E. Landon Drive Anaheim, CA

Snap-Trol 183 Nema 1 Series

Boston Gear Ratiotrol

5001TCP SPEED CONTROLLER

Fincor DC Drives. Flexible & Powerful TYPICAL APPLICATIONS. Conveyor Rugged. Extruder Reliable. Conveyor Simple. Mixer Flexible

INSTALLATION AND OPERATION MANUAL SUPPLEMENT KBPC-225 (PART NOS & 9392)

NEMA 1, NEMA 4X and Chassis Mount Adjustable Speed Controls for DC Motors

KBMD-240D MULTI-DRIVE

MDCKB VAC, 8A Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

KBPC-240D (Part Nos and 9342) Installation and Operation Manual Supplement

MDC Series

2122H. Arm Field Arm Field 1/8-1/ / /8-1/ / / /

CABINET REEL OPERATING INSTRUCTIONS

CABINET REEL OPERATING INSTRUCTIONS

MDC Series

MDC VAC Input Brushless Controller. User s Guide E. Landon Drive Anaheim, CA

MDC Series

MBDC V. 110VAC Input Brush DC Controller. User s Guide East Landon Drive, Anaheim, CA

SERIES 2335 SINGLE-PHASE ADJUSTABLE-SPEED DC MOTOR CONTROLLERS (1/6-2 HP)

Boston Gear Ratiotrol

USER'S MANUAL MODEL DPS32PG1 DRIVER PACK

MDC V, 30A Brushless Controller. User s Guide L East Orangefair Lane, Anaheim, CA

65E CONTROL SERIES CONTROLS. Instruction Manual. For DC Input Variable Speed Controls. P.0. Box W. 106th Street Zionsville, Indiana 46077

BLWR23MDA Series. 24V, 15A Brushless Controller / Motor. User s Guide E. Landon Drive Anaheim, CA

Copyright 2013 Automationdirect.com Incorporated All Rights Reserved

MBDC V, 10A Brush Controller. User s Guide East Landon Drive, Anaheim, CA

5001TCP SPEED CONTROLLER

MBDC V, 30A Brush Controller. User s Guide E. Landon Drive Anaheim, CA

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

BLY34MDA Series. 50V, 30A Brushless Controller / Motor. User s Guide E Landon Drive, Anaheim, CA

MDCSL V, 30A

REDI-LINE. Rugged, Reliable, DC to AC Power Conversion ELECTRIC GENERATORS USER'S GUIDE. KARAM A.L.

BSC Series

Fincor Series 2230 MKII/2240

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

BLDC SPEED CONTROL INSTRUCTION MANUAL Low voltage Brushless DC control

TRAC-3 TENSION READOUT AND CONTROL

RBD Series. Installation and Maintenance Manual. An Altra Industrial Motion Company

DPS32001 and DPS32PS1

DC3N Non-Regenerative DC Drives

Series 5 Inverter OPEN CHASSIS MOUNT - SINGLE PHASE INPUT. For Catalog Nos. ID56F50-CO, ID5601-CO & ID5602-CO

BLY17MDA Series. 24V, 10A Brushless Controller/Motor. User s Guide E. Landon Drive Anaheim, CA

BLWS23MDAxS-160 Offline Series 110VAC, 3A Brushless Controller / Motor

KBVF Adjustable Frequency Drive

DC Variable Speed Drive Panel

PALLET MASTER (PMD) OPERATING INSTRUCTIONS

Transcription:

MM501U User s Manual SCR, Dual-Voltage, Adjustable Speed Drive for DC Brush Motors

Copyright 2002 by Minarik Corporation All rights reserved. No part of this manual may be reproduced or transmitted in any form without written permission from Minarik Corporation. The information and technical data in this manual are subject to change without notice. Minarik Corporation and its Divisions make no warranty of any kind with respect to this material, including, but not limited to, the implied warranties of its merchantability and fitness for a given purpose. Minarik Corporation and its Divisions assume no responsibility for any errors that may appear in this manual and make no commitment to update or to keep current the information in this manual. MVD091302 Printed in the United States of America.

i Safety Warnings SHOCK HAZARD AVOID HEAT KEE DR OID ATION This symbol denotes an important safety tip or warning. Please read these instructions carefully before performing any of the procedures contained in this manual. DO NOT INSTALL, REMOVE, OR REWIRE THIS EQUIPMENT WITH POWER APPLIED. Have a qualified electrical technician install, adjust and service this equipment. Follow the National Electrical Code and all other applicable electrical and safety codes, including the provisions of the Occupational Safety and Health Act (OSHA), when installing equipment. Reduce the chance of an electrical fire, shock, or explosion by proper grounding, over-current protection, thermal protection, and enclosure. Follow sound maintenance procedures. It is possible for a drive to run at full speed as a result of a component failure. Minarik strongly recommends the installation of a master switch in the main power input to stop the drive in an emergency. Circuit potentials are at 115 VAC or 230 VAC above earth ground. Avoid direct contact with the printed circuit board or with circuit elements to prevent the risk of serious injury or fatality. Use a non-metallic screwdriver for adjusting the calibration trimpots. Use approved personal protective equipment and insulated tools if working on this drive with power applied.

ii Contents Specifications 1 Dimensions 2 Installation 3 Mounting.............................................3 Fuses...............................................4 Wiring...............................................4 Cage-clamp Terminal Block...............................5 Speed adjust potentiometer...............................6 Shielding guidelines...................................7 Connections...........................................8 Power, fuse and motor connections.......................8 Power input.........................................9 Motor.............................................9 Field Output.......................................11 Start/Stop Pushbuttons...............................11 Tachogenerator Feedback.............................12 Voltage Signal......................................12 Current Signal......................................12 Operation 14 Before applying power:.................................14 Startup.............................................15 Diagnostic LEDs......................................16 Line starting and line stopping..........................17 Start/Stop Pushbuttons................................17 Dynamic Braking....................................17 Calibration 20 Maximum Speed (MAX SPD)............................22 Minimum Speed (MIN SPD).............................22

iii Current Limit.........................................23 IR Compensation (IR COMP)............................24 Acceleration (ACCEL)..................................26 Deceleration (DECEL)..................................26 TACH VOLTS.........................................27 Application Notes 30 Multiple Fixed Speeds..................................30 Adjustable speeds using potentiometers in series.............31 Independent adjustable speeds...........................32 Reversing...........................................33 Reversing with a DLC600 controller.......................34 Troubleshooting 35 Before troubleshooting.................................35 Replacement Parts....................................39 Unconditional Warranty 41inside back cover Tables Table 1. Field Ouptut Connections..........................11 Table 2. Recommended Dynamic Brake Resistor Sizes..........18 Table 3. Replacement Parts...............................39

iv Illustrations Figure 1. MM501U Dimensions..............................2 Figure 2. Cage-Clamp Terminal Block.........................5 Figure 3. Speed Adjust Potentiometer.........................6 Figure 4. MM501U Connections............................10 Figure 5. Voltage or Current Signal Connections................13 Figure 6. Diagnostic LED Locations..........................16 Figure 7. Dynamic Brake Connection........................19 Figure 8. Calibration Trimpot Layout.........................21 Figure 9. CURRENT LIMIT and IR COMP Settings..............25 Figure 10. Feedback Switch (SW503) Location.................28 Figure 11. Tachogenerator Connections......................29 Figure 12. Multiple Fixed Speeds...........................30 Figure 13. Adjustable Speeds Using Potentiometers in Series......31 Figure 14. Independent Adjustable Speeds....................32 Figure 15. Reversing Circuit...............................33 Figure 16. Independent Forward and Reverse Speeds............34

1 Specifications Model Number Type Line Fuse Rating Field Fuse Rating Horsepower Range @ 90 VDC Output Horsepower Range @ 180 VDC Output Maximum Armature Voltage Range @ 115 VAC Input Maximum Armature Voltage Range @ 230 VAC Input Minimum Speed Adjustment Range @ 115 VAC Input Minimum Speed Adjustment Range @ 230 VAC Input Maximum Armature Current MM501U Open Chassis 40A (Buss Type SC-40 or equivalent) 3A, fast-acting 1-2.5 HP 2-5 HP 0-90 VDC 0-180 VDC 0-60 VDC 0-120 VDC 25 ADC Field Voltage @ 115 VAC Input 50 VDC (F1 to L1) or 100 VDC (F1 to F2) Field Voltage @ 230 VAC Input 100 VDC (F1 to L1) or 200 VDC (F1 to F2) Form Factor 1.37 Acceleration Time Range (no load) 0-90 VDC Armature Voltage 0.5-12 seconds 0-180 VDC Armature Voltage 0.5-12 seconds Deceleration Time Range (no load) 0-90 VDC Armature Voltage 0.5-12 seconds 0-180 VDC Armature Voltage 0.5-12 seconds Analog Input Voltage Range (grounded and isolated signal; S1 to S2) 0-10 VDC Speed Adjustment Potentiometer 10Kohm Approximate Input Impedance (S1 to S2; voltage signal setting) 100K ohm Speed Regulation (% of base speed) Armature Feedback 1% or better Tachogenerator Feedback 0.1% Tachogenerator Feedback Voltage Range Weight Ambient Operating Temperature Range * 7-50 VDC per 1000 RPM 3.8 lb see notes Notes: * 10º - 40ºC when mounted flat (horizontally), or in an enclosure whose volume is between 4 and 6 cubic feet; 10ºC - 50ºC when mounted upright (with heatsink fins vertical) in an enclosure greater than 6 cubic feet.

C507 + B2 2 Dimensions L1 L2 F1 FU504 9.80 [249] 7.00 [178] F2 A1 A2 TB501 + D503 T501 P IN OUT D504 R505 R504 R501 SC SCR502 AC2 AC1 SCR C504 C503 IN COM SCR504 IC504 C508 SCR5 POWER CL RUN IL501 IL502 IL503 C501 C502 ACCEL DECEL MAX MIN TB502 K501 B1 B3 S1 S2 S3 T1 T2 1.40 [36] 6.30 [160] 6.90 [175] 2.50 [66] ALL DIMENSIONS IN INCHES [MILLIMETERS] FOUR (4) MOUNTING SLOTS 0.19 [5] X 0.30 [8] DEEP Figure 1. MM501U Dimensions

3 Installation Mounting Warning Do not install, rewire, or remove this control with input power applied. Doing so may cause fire or serious injury. Make sure you have read and understood the Safety Warnings on page i before attempting installation. Drive components are sensitive to electrostatic fields. Avoid direct contact with the circuit board. Hold drive by the chassis only. Protect the drive from dirt, moisture, and accidental contact. Provide sufficient room for access to the terminal block and calibration trimpots. Mount the drive away from heat sources. Operate the drive within the specified ambient operating temperature range. Prevent loose connections by avoiding excessive vibration of the drive. Mount drive with its board in either a horizontal or vertical plane (vertical mounting is preferred; see Figure 1, page 2). Four 0.19 in. (5 mm) wide slots in the chassis accept #8 pan head screws. Fasten either the large base or the narrow flange of the chassis to the subplate. The chassis must be earth grounded. Use a star washer beneath the head of at least one of the mounting screws to penetrate the anodized chassis surface and to reach bare metal.

4 Installation Fuses MM501U drives have two 40A line fuses installed in Fuse Holder 501 (FH501). Line fuses are rated for maximum rated horsepower. Resize line fuses if using a smaller horsepower motor. Size fuses for approximately 150% of the maximum motor armature current. Wiring One 3A field fuse (FU503) is also installed on the drive. This fuse does not have to be resized if using a smaller horsepower motor. Warning Do not install, remove, or rewire this equipment with power applied. Failure to heed this warning may result in fire, explosion, or serious injury. Circuit potentials are at 115 or 230 VAC above ground. To prevent the risk of injury or fatality, avoid direct contact with the printed circuit board or with circuit elements. Do not disconnect any of the motor leads from the drive unless power is removed and the drive is disabled. Opening any one motor lead may destroy the drive. Use 18 AWG wire for speed adjust potentiometer wiring. Use 16 AWG wire for field (F1, F2) wiring. Use 14 AWG wire for AC line (L1, L2) and motor (A1, A2) wiring.

Installation 5 Cage-clamp Terminal Block MM501U drives use a cage-clamp terminal block for terminal block 502 (TB502). To connect a wire to the cage-clamp terminal block (see Figure 2), use a small screwdriver to press down on the lever arm. Insert a wire stripped approximately 0.25 inches (6 mm) into the opening in front of the terminal block. Release the lever arm to clamp the wire. Press down on the lever arm using a small screwdriver. 1 2 3 Insert wire into the wire clamp. Release the lever arm to clamp the wire. Figure 2. Cage-Clamp Terminal Block

6 Installation Speed adjust potentiometer Warning Be sure that the potentiometer tabs do not make contact with the potentiometer enclosure. Grounding the input will cause damage to the drive. Mount the speed adjust potentiometer through a 0.38 in. (10 mm) hole with the hardware provided (Figure 3). Install the circular insulating disk between the panel and the 10K ohm speed adjust potentiometer. Twist the speed adjust potentiometer wire to avoid picking up unwanted electrical noise. If speed adjust potentiometer wires are longer than 18 in. (457 mm), use shielded cable. Keep speed adjust potentiometer wires separate from power leads. MOUNT THROUGH A 0.38 IN. (10 MM) HOLE CW WIPER W NUT STAR WASHER SPEED ADJUST POTENTIOMETER PANEL INSULATING DISK Figure 3. Speed Adjust Potentiometer

Installation 7 Shielding guidelines Warning Under no circumstances should power and logic leads be bundled together. Induced voltage can cause unpredictable behavior in any electronic device, including motor controls. As a general rule, Minarik recommends shielding of all conductors. If it is not practical to shield power conductors, Minarik recommends shielding all logic-level leads. If shielding logic leads is not practical, the user should twist all logic leads with themselves to minimize induced noise. It may be necessary to earth ground the shielded cable. If noise is produced by devices other than the drive, ground the shield at the drive end. If noise is generated by a device on the drive, ground the shield at the end away from the drive. Do not ground both ends of the shield. If the drive continues to pick up noise after grounding the shield, it may be necessary to add AC line filtering devices, or to mount the drive in a less noisy environment.

8 Installation Connections Warning Do not connect this equipment with power applied. Failure to heed this directive may result in fire or serious injury. Minarik strongly recommends the installation of a master power switch in the voltage input line, as shown in Figure 4, page 10. The switch contacts should be rated at a minimum of 200% of motor nameplate current and 250 volts. Power, fuse and motor connections Connect the power input leads, an external line fuse and a DC motor to the drive s printed circuit board (PCB) as shown in Figure 4, page 10.

Installation 9 Power input Connect the AC line power leads to terminals L1 and L2, or to a double-throw, single-pole master power switch (recommended). Motor Minarik drives supply motor voltage from A1 and A2 terminals. It is assumed throughout this manual that, when A1 is positive with respect to A2, the motor will rotate clockwise (CW) while looking at the output shaft protruding from the front of the motor. If this is opposite of the desired rotation, simply reverse the wiring of A1 and A2 with each other. Connect a DC motor armature to PCB terminals A1 and A2 as shown in Figure 4, page 10. Ensure that the motor voltage rating is consistent with the drive s output voltage.

10 Installation + POWER CL RUN IL501 IL502 IL503 VOLTS C508 + C506 C507 FU504 C503 IN TACHOGENERATOR (OPTIONAL) NEG (-) POS (+) C501 C502 + ACCEL DECEL P506 P505 MAX MIN IC501 IC502 SPD SPD B1 B2 B3 S2 T1 T2 K501 CW 10KOHM SPEED ADJUST POTENTIOMETER START (N.O.) STOP (N.C.) SIGNAL CONNECTIONS TB501 F2 A1 A2 POS (+) MOTOR NEG (-) F1 FIELD OUTPUT SHUNT WOUND MOTORS ONLY POWER CONNECTIONS L1 L2 EMERGENCY STOP SWITCH 115/230 VAC INPUT VOLTAGE Figure 4. MM501U Connections

Installation 11 Field Output The field output is for shunt wound motors only. DO NOT make any connections to the field output when using a permanent magnet motor. Table 1 lists the field output connections. Table 1. Field Ouptut Connections Line Voltage Approximate Field Field (VAC) Voltage (VDC) Connections 115 50 F1 and L1 115 100 F1 and F2 230 100 F1 and L1 230 200 F1 and F2 Use 18 AWG wire to connect the field output to a shunt wound motor. Start/Stop Pushbuttons The drive can be operated with Start/Stop pushbuttons to start and stop the motor (pushbuttons are not included with the drive). See Figure 4 (page 10) for connections. Connect a momentary operated, normally closed STOP pushbutton to B2 and B3. Connect a momentary operated, normally open START pushbutton to B2 and B3. If the Start/Stop pushbuttons are not used, jumper terminal B1 and B3. As an added safety feature, the Start/Stop pushbutton terminals (B1, B2, and B3) are isolated from earth ground.

12 Installation Tachogenerator Feedback Using tachogenerator feedback will improve speed regulation from approximately 1% of motor base speed to approximately 0.1% of motor base speed. Use tachogenerators rated from 7 VDC per 1000 RPM to 50 VDC per 1000 RPM. Connect the tachogenerator to terminals T1 (-) and T2 (+) of terminal block 502 (TB502). See Figure 4 (page 10) for tachogenerator feedback connections. Voltage Signal Instead of using a speed adjust potentiometer, the drive may be wired to follow a grounded or ungrounded 0-10 VDC signal. Connect the signal input (+) to S2 and the signal common (-) to S1 (see Figure 5, page 13). Make no connections to S3. NOTE: Set SW505 to VOLTAGE SIGNAL if the drive is following a voltage signal. Current Signal The MM501U can follow a 4-20 ma current signal. Connections are the same as the voltage follower. Connect the signal input to S1 and S2 (see Figure 5, page 13). Make no connections to S3. NOTE: Set SW503 to CURRENT SIGNAL when the drive is follow a current signal.

Installation 13 ACCEL DECEL P506 P505 P502 B1 B2 B3 S1 S2 S3 T1 T2 + - 0-10 VDC VOLTAGE SIGNAL or 4-20 ma CURRENT SIGNAL P501 IC501 IC502 K501 MIN SPD VOLTAGE SIGNAL CURRENT SIGNAL TB502 IC505 C506 C507 Figure 5. Voltage or Current Signal Connections

14 Operation Warning Dangerous voltages exist on the drive when it is powered. BE ALERT. High voltages can cause serious or fatal injury. For your safety, use personal protective equipment (PPE) when operating this drive. To avoid drive or motor damage, change switch settings only when the drive is disconnected from the AC line voltage. Make sure all switches are set to their correct position. Before applying power Verify that no conductive material is present on the printed circuit board. Set SW501 and SW502 to either 115 or 230 to match the AC line voltage. Set SW503 to either TACH for tachogenerator feedback or ARM for armature feedback. Set SW504 to either 90 or 180 to match the motor armature voltage. Set SW505 to either CURRENT SIGNAL or VOLTAGE SIGNAL to match the input signal being used. If a speed adjust potentiometer is being used, set the switch to VOLTAGE SIGNAL.

Operation 15 Startup 1. Turn the speed adjust potentiometer full counterclockwise (CCW). If the drive is following a voltage signal, set the voltage signal to 0 VDC. If the drive is following a current signal, set the current signal to minimum. 2. Apply AC line voltage. 3. Slowly advance the speed adjust potentiometer clockwise (CW). If a voltage or current signal is used, slowly increase the voltage or current signal. The motor slowly accelerates as the potentiometer is turned CW, or the voltage or current signal is increased. Continue until the desired speed is reached. 4. Remove AC line voltage from the drive to coast the motor to a stop.

16 Operation Diagnostic LEDs The MM501U is equipped with the following diagnostic LEDs: POWER: Lights whenever AC line voltage is applied to the drive. CURRENT LIMIT (CL): Lights whenever the drive reaches current limit. RUN: Lights whenever the motor is rotating. DIAGNOSTIC LEDs SCR505 D504 R505 R504 R501 SCR504 C503 P503 P504 P507 POWER CL RUN IL501 IL502 IL503 LIMIT C501 C502 DECEL ACCEL IC502 P502 P501 CURRENT SIGNAL TB502 B2 B1 B3 S2 S1 T1 S3 T2 K501 Figure 6. Diagnostic LED Locations

Operation 17 Line starting and line stopping Line starting and line stopping (applying and removing AC line voltage) is recommended for infrequent starting and stopping of a drive only. When AC line voltage is applied to the drive, the motor accelerates to the speed set by the speed adjust potentiometer. When AC line voltage is removed, the motor coasts to a stop. Start/Stop Pushbuttons. Start/Stop pushbuttons allow you to accelerate the motor to set speed, and to decelerate the motor to a stop. See Figure 4, page 10 for connection information. Dynamic Braking Dynamic braking may be used to rapidly stop a motor (Figure 7, page 19). For the RUN/BRAKE switch, use a three-pole, doublethrow switch rated for at least the maximum DC armature voltage and maximum braking current. Size the dynamic braking resistor according to the motor current rating (Table 2, page 18). The dynamic brake resistance listed in the table is the smallest recommended resistance allowed to prevent possible demagnetization of the motor. The motor stops less rapidly with higher brake resistor values.

18 Operation Table 2. Recommended Dynamic Brake Resistor Sizes Motor Armature Minimum Dynamic Minimum Dynamic Current Rating Brake Resistor Brake Resistor (ADC) Value (Ohms) Power (Watts) Less than 2 1 1 2-3 5 5 3-5 10 10 5-10 20 20 10-17 40 50 17-30 100 200 For motors rated 1/17 horsepower and less, a dynamic brake resistor is not necessary since the armature resistance is high enough to stop the motor without demagnetization. Replace the dynamic brake resistor with 12 gauge wire.

Operation 19 MM501U A1 A2 B1 B3 DYNAMIC BRAKE RESISTOR RUN BRAKE MOTOR Figure 7. Dynamic Brake Connection

20 Calibration Warning Dangerous voltages exist on the drive when it is powered. When possible, disconnect the voltage input from the drive before adjusting the trimpots. If the trimpots must be adjusted with power applied, use insulated tools and the appropriate personal protection equipment. BE ALERT. High voltages can cause serious or fatal injury. The MM501U is factory calibrated with a 2 HP, 180 VDC motor. Re-adjust the calibration trimpot settings to accommodate motors with different ratings. All adjustments increase with CW rotation, and decrease with CCW rotation. Use a non-metallic screwdriver for calibration. Each trimpot is identified on the printed circuit board. See Figure 8, page 21 for trimmer pot locations on the PCB.

Calibration 21 4 SCR505 D504 R501 R504 R505 CURRENT LIMIT IR COMP TACH VOLTS P503 P504 P507 POWER CL RUN 09 IL501 IL502 IL503 C501 C502 ACCELERATION DECELERATION ACCEL DECEL MAX MIN P505 P506 P501 TB502 P502 CURRENT SIGNAL VOLTAGE SIGNAL B1 B2 B3 S1 S2 S3 T1 T2 K501 Figure 8. Calibration Trimpot Layout

22 Calibration Maximum Speed (MAX SPD) The MAX SPD trimpot setting determines the maximum speed. It is factory set for maximum rated motor speed. To calibrate MAX SPD: 1. Set the MAX SPD trimpot full CCW. 2. Turn the speed adjust potentiometer full CW. 3. Adjust the MAX SPD trimpot CW until the desired maximum motor speed is reached. Minimum Speed (MIN SPD) The MIN SPD setting determines the motor speed when the speed adjust potentiometer is turned full CCW. It is factory set to zero speed. To calibrate MIN SPD: 1. Set the MIN SPD trimpot full CCW. 2. Turn the speed adjust potentiometer full CCW. 3. Adjust the MIN SPD trimpot CW until the desired maximum motor speed is reached.

Calibration 23 Current Limit Warning TORQUE should be set to 120% of motor nameplate current rating. Continuous operation beyond this rating may damage the motor. If you intend to operate beyond the rating, contact your Minarik representative for assistance. The CURRENT LIMIT setting determines the maximum armature output of the drive. It is factory set at 120% of rated motor current. Re-calibrate the CURRENT LIMIT when using a lower current rated motor. See Figure 9, page 25 for approximate trimpot settings or re-calibrate using the following procedures: 1. With the power disconnected from the drive, connect a DC ammeter in series with the armature. 2. Set the TORQUE trimpot to minimum (full CCW). 3. Set the speed adjust potentiometer to maximum speed (full CW). 4. Carefully lock the motor armature. Be sure that the motor is firmly mounted. 5. Apply line power. The motor should be stopped. 6. Slowly adjust the TORQUE trimpot CW until the armature current is 120% of motor rated armature current. 7. Turn the speed adjust potentiometer CCW until the motor stops. 8. Remove line power. 9. Remove the stall from the motor. 10. Remove the ammeter in series with the motor armature if it is no longer needed.

24 Calibration IR Compensation (IR COMP) The IR COMP trimpot setting determines the degree to which motor speed is held constant as the motor load changes. It is factory set for optimum motor regulation. Refer to Figure 9 on page 25 for recommended settings or use the following procedure to recalibrate the IR COMP setting: 1. Set the IR COMP trimpot to minimum (full CCW). 2. Rotate the speed adjust potentiometer until the motor runs at midspeed without load (for example, 900 RPM for an 1800 RPM motor). A hand held tachometer may be used to measure motor speed. 3. Load the motor armature to its full load armature current rating. The motor should slow down. 4. While keeping the load on the motor, rotate the IR COMP trimpot CW until the motor runs at the speed measured in step 2. If the motor oscillates (overcompensation), the IR COMP trimpot may be set too high (CW). Turn the IR COMP trimpot CCW to stabilize the motor. 5. Unload the motor.

Calibration 25 LIMIT 5 HP 180 VDC 1750 RPM 24 AMPS LIMIT 1 1/2 HP 180 VDC 1800 RPM 7 AMPS 3 HP 180 VDC 1750 RPM 13.7 APMS 1 HP 90 VDC 10 AMPS 2 HP 180 VDC 1750 RPM 9.2 AMPS Figure 9. CURRENT LIMIT and IR COMP Settings

26 Calibration Acceleration (ACCEL) The ACCEL setting determines the time the motor takes to ramp to a higher speed. See Specifications on page 1 for approximate acceleration times. The ACCEL setting is factory set to its minimum value (full CCW). Turn the ACCEL trimpot CW to increase the acceleration time, and CCW to decrease the acceleration time. Deceleration (DECEL) The DECEL setting determines the time the motor takes to ramp to a lower speed. See Specifications on page 1 for approximate deceleration times. The DECEL setting is factory set to its minimum value (full CCW). Turn the DECEL trimpot CW to increase the deceleration time, and CCW to decrease the deceleration time.

Calibration 27 TACH VOLTS Warning Calibrate the TACH VOLTS setting only when a tachogenerator is used. The TACH VOLTS setting, like the IR COMP setting, determines the degree to which motor speed is held constant as the motor load changes. To calibrate the TACH VOLTS trimpot: 1. Connect the tachogenerator to T1 and T2. The polarity is positive (+) for T1 and negative (-) for T2 when the motor is running in the forward direction. 2. Set switch 503 (SW503) to ARM for armature feedback. 3. Set the speed adjust potentiometer full CW. Measure the armature voltage across A1 and A2 using a voltmeter. 4. Set the speed adjust potentiometer to 0 (zero speed). 5. Set SW503 to TACH for tachogenerator feedback. 6. Set the IR COMP trimpot to full CCW. 7. Set the TACH VOLTS trimpot to full CW. 8. Set the speed adjust potentiometer to full CW. 9. Adjust the TACH VOLTS trimpot until the armature voltage is the same value as the voltage measured in step 3. Check that the TACH VOLTS is properly calibrated. The motor should run at the same set speed when SW503 is set to either armature or tachogenerator feedback.

28 Calibration SCR505 D504 R505 R504 R501 P503 P504 P507 2 IL502 SCR504 IL501 P502 P501 + + C506 C507 C504 C503 C509 IN SW503 FEEDBACK SWITCH POWER CL RUN C501 C502 B2 B1 B3 S2 S1 T1 S3 T2 K501 LIMIT DECEL ACCEL P5 CURRENT SIGNAL COM Figure 10. Feedback Switch (SW503) Location

Calibration 29 TACH-GENERATOR (optional) NEG (-) LIMIT DECEL ACCEL P502 B2 B1 B3 S2 S1 T1 S3 T2 IL502 P501 C506 C507 C503 + C509 K501 IL501 P5 C501 C502 CURRENT SIGNAL POS (+) COM Figure 11. Tachogenerator Connections

30 Application Notes Multiple Fixed Speeds Replace the speed adjust potentiometer with series resistors with a total series resistance of 10K ohms (Figure 12). Add a single-pole, multi-position switch with the correct number of positions for the desired number of fixed speeds. R1 S3 S2 S1 R2 R3 TOTAL SERIES RESISTANCE 10K OHMS R4 Figure 12. Multiple Fixed Speeds

Application Notes 31 Adjustable speeds using potentiometers in series Replace the speed adjust potentiometer with a single-pole, multiposition switch, and two or more potentiometers in series, with a total series resistance of 10K ohms. Figure 13 shows a connection for fixed high and low speed adjust potentiometers. CW S3 S2 S1 HIGH SPEED LOW SPEED 5K OHM CW 5K OHM Figure 13. Adjustable Speeds Using Potentiometers in Series

32 Application Notes Independent adjustable speeds Replace the speed adjust potentiometer with a single-pole, multiposition switch, and two or more potentiometers in parallel resistance of 10K ohms. Figure 14 shows the connection of two independent speed adjust potentiometers that can be mounted at two separate operating stations. S3 SPEED 2 CW CW S2 S1 SPEED 1 20K OHM 20K OHM Figure 14. Independent Adjustable Speeds

Application Notes 33 Reversing To reverse motor direction, use a dynamic brake and a three-pole, three-position switch rated for at least the maximum DC armature voltage and maximum braking current. See Figure 15 for connections. Wait for the motor to stop completely before switching it to either the forward or reverse direction. See the Dynamic Braking section on page 17 for sizing the dynamic brake resistor. MM501U A1 A2 B1 B3 DYNAMIC BRAKE RESISTOR BRAKE FWD REV MOTOR Figure 15. Reversing Circuit

34 Application Notes Reversing with a DLC600 controller A DLC600 controller, can be used in a reversing application. The DLC600 must be inhibited while braking. Without the inhibit feature, the DLC600 will continue to regulate. This will cause overshoot when the DLC600 is switched back to the drive. Figure 16 show the connection of the reversing circuit to an MM501U drive and a DLC600. Note: Only one DLC option (Optical Encoder or Magnetic Pickup) may be used simultaneously. MINARIK DRIVE S3 S2 S1 A1 A2 Dynamic Brake Resistor S1 S2 FWD BRAKE REV DLC600 Inhibit Leads Motor C IN + Common Optical Encoder Signal +5 VDC Magnetic Pickup Figure 16. Independent Forward and Reverse Speeds

35 Troubleshooting Warning Dangerous voltages exist on the drive when it is powered. When possible, disconnect the drive while troubleshooting. High voltages can cause serious or fatal injury. Before troubleshooting Perform the following steps before starting any procedure in this section: 1. Disconnect AC line voltage from the drive. 2. Check the drive closely for damaged components. 3. Check that no wire chips or other foreign material has become lodged on the printed circuit board. 4. Verify that every connection is correct and in good condition. 5. Verify that there are no short circuits or grounded connections. 6. Check that the voltage selection switch settings match the AC line voltage. For additional assistance, contact your local Minarik distributor, or the factory direct: 1-800-MINARIK (646-2745) or Fax: 1-800-394-6334

36 Troubleshooting Problem Line fuse blows. Possible Causes 1. Line fuse is the wrong size. 2. Motor cable or armature is shorted to ground. 3. Nuisance tripping caused by a combination of ambient conditions and high-current spikes (i.e. reversing). Suggested Solutions 1. Check that the line fuse is correct for the motor size. 2. Check motor cable and armature for shorts. 3. Add a blower to cool the drive components; decrease CURRENT LIMIT setting, or resize motor and drive for actual load demand. Check for incorrectly aligned mechanical components or jams.

Troubleshooting 37 Problem Line fuse does not blow, but the motor does not run. Possible Causes 1. Speed adjust potentiometer or reference voltage is set to zero speed. 2. Speed adjust potentiometer or reference voltage is not connected to drive input properly; connections are open. 3. The drive is not receiving AC line voltage. 4. Drive is in current limit. The red CURRENT LIMIT LED must be off. Suggested Solutions 1. Increase the speed adjust potentiometer setting or reference voltage. 2. Check connections to input. Verify that connections are not open. 3. Verify that the drive is receiving AC line voltage. The green POWER LED should be lit when AC line voltage is applied. 4. If the red CURRENT LIMIT LED is on, verify that the motor is not jammed. It may be necessary to increase the CURRENT LIMIT trimpot setting.

38 Troubleshooting Problem Motor runs too fast. Motor will not reach the desired speed. Possible Causes 1. MAX SPD not calibrated. 1. MAX SPD setting is too low. 2. IR COMP setting is too low. 3. Motor is overloaded. Suggested Solutions 1. Calibrate MAX SPD. 1. Increase MAX SPD setting. 2. Increase IR COMP setting. 3. Check motor load. Resize the motor and drive if necessary. Motor pulsates or surges under load. 1. IR COMP is set too high. 2. Motor bouncing in and out of current limit. 1. Adjust the IR COMP setting slightly CCW until the motor speed stabilizes. 2. Make sure motor is not undersized for load; adjust CURRENT LIMIT trimpot CW.

Troubleshooting 39 Replacement Parts Replacement parts are available form Minarik Corporation and its distributors for this drive series. Table 3. Replacement Parts Model No. Symbol Description Minarik P/N MM501U D501,502 3A, 800V Diode 071-0003 D503,504 1.5A, 600V PIV Diode 071-0012 IC505 IS0122P IC 060-0106 IC506 4N35 Opto-Coupler 060-0101 R501.002 OHM, 13W Resistor 032-0133 SCR501-505 800V, 65A SCR 072-0059 T501 3FD-436 Transformer 230-0072 FU501,502 40A Fuse 050-0060 FU503 3A, Fast-Acting Fuse 050-0021 Heat Sink 223-0294 10 Kohm Potentiometer Kit 202-0003

40 NOTES

Unconditional Warranty A. Warranty Minarik Corporation (referred to as "the Corporation") warrants that its products will be free from defects in workmanship and material for twelve (12) months or 3,000 hours, whichever comes first, from date of manufacture thereof. Within this warranty period, the Corporation will repair or replace, at its sole discretion, such products that are returned to Minarik Corporation, 901 East Thompson Avenue, Glendale, CA 91201-2011 USA. This warranty applies only to standard catalog products, and does not apply to specials. Any returns for special controls will be evaluated on a case-by-case basis. The Corporation is not responsible for removal, installation, or any other incidental expenses incurred in shipping the product to and from the repair point. B. Disclaimer The provisions of Paragraph A are the Corporation's sole obligation and exclude all other warranties of merchantability for use, express or implied. The Corporation further disclaims any responsibility whatsoever to the customer or to any other person for injury to the person or damage or loss of property of value caused by any product that has been subject to misuse, negligence, or accident, or misapplied or modified by unauthorized persons or improperly installed. C. Limitations of Liability In the event of any claim for breach of any of the Corporation's obligations, whether express or implied, and particularly of any other claim or breech of warranty contained in Paragraph A, or of any other warranties, express or implied, or claim of liability that might, despite Paragraph B, be decided against the Corporation by lawful authority, the Corporation shall under no circumstances be liable for any consequential damages, losses, or expense arising in connection with the use of, or inability to use, the Corporation's product for any purpose whatsoever. An adjustment made under warranty does not void the warranty, nor does it imply an extension of the original 12-month warranty period. Products serviced and/or parts replaced on a no-charge basis during the warranty period carry the unexpired portion of the original warranty only. If for any reason any of the foregoing provisions shall be ineffective, the Corporation's liability for damages arising out of its manufacture or sale of equipment, or use thereof, whether such liability is based on warranty, contract, negligence, strict liability in tort, or otherwise, shall not in any event exceed the full purchase price of such equipment. Any action against the Corporation based upon any liability or obligation arising hereunder or under any law applicable to the sale of equipment or the use thereof, must be commenced within one year after the cause of such action arises.

901 E Thompson Avenue Glendale, CA 91201-2011 Tel.: 1-800-MINARIK (646-2745) Fax: 1-800-394-6334 www.minarikcorp.com Document number 250-0215, Revision 2 Printed in the U.S.A September 2002