SKX 16, 18, 20 II 2GD. Ex d e mb ia/ib IIC T4...T6 Gb Ex tb IIIC T80 C Db -20ºC Ta +50ºC -50ºC Ta +50ºC Degree of protection: IK 08

Similar documents
USER MANUAL FOR THE BULKHEAD LIGHT FITTING, TYPE /..

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

About us. 2 make your work surroundings safer

Control Units Ex e Glass Fiber Reinforced Polyester

EX-REPAIR AND MAINTENANCE RECEPTACLES

Linear Luminaire with LED Series EXLUX 6402/2

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

EX-D ENCLOSURES AND DISTRIBUTIONS

HTSB system System overview

Number: TEPEx.RS.067 Rev : 02 Date: Manufacturer General safety information s Purpose Degree of protection 2.

Terminal Boxes in Stainless Steel SLS**.T

Compact Sheet-Steel Light Fittings Series 6114/1

CCAI, CCAIF, CCAIF..H

M-0. M-0... series control, monitoring and signalling devices. Ex e

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear luminaire with LED Series EXLUX 6002

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

Linear Luminaire with LED Series EXLUX 6002

I Ex-safety switches I

Terminal Boxes Series 8125

The cover screws and all other external metal parts are made of stainless steel (AISI 316L). International approvals

Linear fluorescent luminaire LED V-CG-S

Emergency Luminaire with LED Series EXLUX 6409/1

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

EXEL-L. Detail of the internal side. Transparent polycarbonate

Floodlight LED Series 6125

SPOOL VALVES solenoid air operated 1/4 to 1/2 tapped body and NAMUR for integrated pilot

USER MANUAL FOR EXPLOSION PROOF FLOODLIGHT tip RLF/

LED Linear Luminaire Series EXLUX 6402

Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Solutions Ex d IIB+H2, Stainless Steel EJBX*

Plug and Socket Devices SolConeX 16 A Series 8570

Pneumatic control unit for decentralized automation of ELEMENT process valves

9.6 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Junction boxes for control, monitoring and control panel Ex tb

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

TBKS/CBKS Stainless Steel Sloping Roof Keyed Terminal Box Zones 1&2, 21&22

Floodlight LED Series 6525

Hazardous Area Electrical Equipment. TBKF/CBKF Stainless Steel Flat Roof Keyed Terminal Box Zones 1&2, 21&22. Index

11 Control Panels, Distribution Panels and Components

Control Stations CP.../EFDCN

Load disconnect switch Series 8146/5-V11

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

The ultimate low voltage temporary LED lighting solution

Operating Instructions

Linear fittings EVDL LED fitting - zones 21, & 22

Load and Motor Switches, Load-Break Switches Series 8549

The ultimate low voltage temporary LED lighting solution

I Ex-safety switches I

Terminal Boxes Series 8125

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

A good connection. International approvals.

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

JBEP Series Fiberglass Reinforced Polyester Terminal Junction Boxes for Instrumentation Applications Increased Safety. Factory Drilled and Equipped

Control Panels, Distribution Panels and Components

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

International approvals.

ALUMINIUM AND STAINLESS STEEL ENCLOSURES - EJB... SERIES

Ex UPS standard Series 8265

ACTUATOR ASSEMBLIES FOR PANEL MOUNT APPLICATIONS

Unused flameproof threads for cable glands have to be closed with certified plugs.

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Accessories for pneumatic stroke and rotary actuators CLASSIC and ELEMENT process valves

FHL. Ex d. Body in aluminium

Ø 68 mm to ø 115 mm. Material: Weight: Shaft Loads: Enclosure Rating: Connection Options. Cable: Cable Glands:

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Terminal Boxes TNCN. Explosion protection Marking

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Control Device System NEC Series ConSig 8040

ADVANCE- GRP[ GD] S ERIES OP TIMA- EX[ GD] S ERIES

DECONTACTOR. FIND ALL INFORMATION ON OUR WEBSITE: marechal.com. Dimensions and certificates

Floodlight LED Series 6525

10 Load and Motor Switchgear

RLFE. Mounting bracket. Ex de. - Fast, easy installation - Suitable for discharge lamps of up to 400W - Robust and safe over time - Zones 1, 2, 21, 22

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Ex d. S.1 series. - Zone 1, 2, 21, 22 - Group IIC - Aluminium junction boxes - Wide selection of models - IP66 / 67. SSC series

I Ex-Safety switches I

Safety Switches Series 8537

Control Buttons / Switches for Panel Mounting Series 8003

7 Lighting Technology

OPERATING INSTRUCTIONS

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

Zone 1 Linear Range - Installation Guide

Type 2REX-A. Oil & Gas / Heavy Industry

Main current switches >180 A are realized in metal enclosures. Internationally approved.

HKH Series. HAZCON Controls for Harsh and Hazardous Environments

Junction Boxes & Enclosures JBES and ECES Series: 316L Stainless Steel Enclosures Increased Safety

Control switch/load disconnect switch Series 8008

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

ATEX CONNECTORS: PLUGS AND SOCKETS

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Linear fittings EVNL LED fitting - zones 2, & 22

EJB. Ex d. Stainless steel bolts. - Zone 1, 2, 21, 22 - Group IIB+H2 - Aluminium junction boxes - Choice of 30 sizes - IP 66 / 67.

Flameproof - Group IIB or IIB + H 2 Carbon steel - DE8BC series. Painted steel. -40 C or -20 C C or +50 C or +60 C

Direct-acting 3/2 way plunger valve

8150 Series Terminal Boxes

Transcription:

Zone 1 21 22 2 SKX 16, 18, 20 IP 66 +50 C 20 Enclosures made of glassfibre reinforced polyester resin or stainless steel AISI 316L 3 basic enclosure sizes in GRP 3 basic enclosure sizes in stainless steel CONSTRUCTION Enclosure: polyester plastic reinforced with glass fiber, color black Stainless steel AISI 316L, brush finished, thickness 1.5mm Cover: with integrated thermoplastic elastomer gasket, closes with four/six M5/M6 stainless steel screws. TECHNICAL DATA Certificate: EXA 13 ATEX 0029, EXA 15 ATEX 0036 RU CHR.AB24.B.03291, RU CHR.AB24.B.03294 Alone or in various combinations of merged set Marking: 0722 Equipped with built in components Ambient temperature ATEX: EAC: Ex d e mb ia/ib IIC T4...T6 Gb Ex tb IIIC T80 C Db 20ºC Ta +50ºC 50ºC Ta +50ºC Degree of protection: IP 66 category 1 Resistance to shock: IK 08 Protection class : Rated voltage: I (protective earthing) 690 V AC (with mantle terminals block SL5, SL8 Ui = 400V AC) Up to 80 A Control devices Apparatus category: Marking of explosion protection: Indicating lamps Pushbuttons Switches Nominal current: PE terminals (inside of the enclosure): Ammeters Connection: Version with hinged doors II 2GD max. 2x4 mm2+2x2,5 mm2, 3x4 mm2, 2x6 mm2 Depending on order requirements at the builtin components or at the terminal blocks. The rated operational voltage, the rated operational current and the rated crosssection depend on the terminal type used and the explosion protected components. Control units SKX 16, SKX 18, SKX 20 are Ex combinations configured according to customer demand. Type designation consists of a basic type designation SKX 16, SKX 18, SKX 20, I for enclosure made of SS AISI 316L and SRU number that represents the number of production and assigns to the increment. Example: SKX 18 I / SRU 1280 managing the combination of the housing MMK 403016 I stainless steel enclosure AISI 316L performed by production number 1280 92 make your work surroundings safer

Control units GRP enclosure SKX 16 Side Cable gland M20 M25 M32 M40 M50 M63 BD 9 9 5 3 3 2 AC 7 5 3 3 GRP enclosure SKX 18 Side Cable gland M20 M25 M32 M40 M50 M63 BD 15 15 9 6 5 4 AC 7 5 3 3 www.tepex.hr All technical data is relevant at the time of print. 93

Zone 1 21 2 22 SKX 16, 18, 20 GRP enclosure SKX 20 Side Cable gland M20 M25 M32 M40 M50 M63 BD 22 22 12 8 6 6 AC 7 5 3 3 Example: Ex control units with GRP enclosures 94 make your work surroundings safer

Control units Stainless steel AISI 316L enclosure SKX 16 I, SKX 18 I, SKX 20 I A[mm] B[mm] C[mm] SKX 16 I 300 200 120 SKX 18 I 400 300 160 SKX 20 I 600 400 160 MOUNTING D[mm] E[mm] F[mm] G[mm] SKX 16 I 255 227 330 152 SKX 18 I 355 327 430 252 SKX 20 I 555 427 630 352 Example: Ex control units with stainless steel AISI 316L enclosures www.tepex.hr 95

Zone 1 21 2 22 SKX 16, 18, 20 BUILDIN COMPONENTS Description, type Schema Overview Control switch SMS 03/. II 2G I M2 Ex de I/IIC Gb Mb Rated voltage: 630 V AC Rated current: 16 A Terminals: 2,5 mm 2 Main curent switch GHG 260 Rated voltage: 690 V AC Rated current : 40 80 A Terminals: 16 25 mm 2 96 make your work surroundings safer

Control units BUILDIN COMPONENTS Description, type Schema Overview Control switch GHG 23. II 2GD Ex de IIC Rated voltage: 690 V AC Rated current : 10 A Terminals: 2,5 mm 2 www.tepex.hr 97

Zone 1 21 2 22 SKX 16, 18, 20 BUILDIN COMPONENTS Description, type Schema Overview Pushbutton PBT/. Rated voltage: 630V AC Rated current: 16A Terminals: 2,5 mm 2 Signal lamp SLP Rated voltage: 12250 V AC/DC Max. current: 208 ma Terminals: 2,5 mm 2 Potentionmeter PBT/POT Rated voltage: 315 V AC/DC Rated power: 1W Scale: 0100% / 270 Tolerance: ±20% Characteristic: linear Terminals: 2,5 mm 2 Resistance R: 1,0 k 2,2 k 4,7 k 10 k 470 k Measuring instruments AM 72, VM 72 Measuring range: AM: n/1 A, 020 ma, 025 A direct 420 ma VM: n/1a, 6415V, 6660 V Scale: according to customer demand Terminals: 1,5 4 mm 2 Mantle terminals SL5, SL8 Rated voltage: 400 V Rated current: 16 A AC Terminals: 4 mm 2 Max. No. of wire under one clamp: 2x4mm 2 + 2x2,5mm 2, 3x4mm2 Terminals TH 357.5 5 terminals 4mm 2 2 terminals 16mm 2 Rated voltage: 690 V AC Rated current: 16 A N/PE busbar (only for SKX 15) 11x max. 2x4mm 2 98 make your work surroundings safer

Control units ACTUATORS AND INDICATORS Description, type Mounting Overview Switch actuator SMO 17/. II 2G II 2D I M2 Ex e I/IIC Gb Mb 0 I I II I 0 II I II III 0 SMO 17/1 SMO 17/2 SMO 17/3 SMO 17/4 1 2 1 2 1 2 1 2 III I 3 3 3 II 4 5 4 6 5 SMO 17/5 SMO 17/6 SMO 17/7 SMO 17/8 SMO 17/9 3 4 Ø87,5 60 Ø5x6 Switch actuator GHG 260 1006 Ø13 Front element of measuring instruments SAM 72 II 2G II 2D I M2 Ex e I/IIC Gb Mb Type SPO 01/. SPO 01/01 0 Puschbitton actuator SPO 01/. II 2G II 2D I M2 Ex e I/IIC Gb Mb SPO 01/02 SPO 01/03 SPO 01/04 SPO 01/05 SPO 01/06 SPO 01/07 SPO 01/08 SPO 01/09 SPO 01/10 I II RED GREEN WHITE START STOP ON OFF Front element of signal lamp SPO 02/. II 2G II 2D I M2 Ex e I/IIC Gb Mb Type SPO 02/. SPO 02/01 RED SPO 02/02 GREEN SPO 02/03 YELLOW SPO 02/04 TRANSPARENT Keyoperated pushbutton actuator GHG 410 1904 R0012 II 2GD Ex e II IP66 www.tepex.hr 99

Zone 1 21 2 22 ACTUATORS AND INDICATORS Description, type Mounting Overview Mushroomhead pushbutton actuator GHG 418 815..R.. (EMERGENCYSTOP) II 2GD Ex e II IP66 SKX 16, 18, 20 Keyoperated mushroomhead pushbutton actuator GHG 418 815..R.. (EMERGENCYSTOP) II 2GD Ex e II IP66 Potentiometer acuator GHG 410 1944 R0010 II 2GD Ex e II IP66 Cable gland SPU ISO 16 ISO 40 II 2G II 2D Ex e I/IIC Gb Cable gland for armourd cable SPU A ISO 16 ISO 40 II 2G II 2D Ex e I/IIC Gb Plug SPC.. ISO 16 ISO M40 II 2G II 2D Ex e I/IIC Gb Connection part SKX 100 make your work surroundings safer

Control units BUILDIN COMPONENTS Description, type Schema Overview Main fuse NH0 300XX, NH0, 301XX BUILD IN SOCKET 16 A (3p/5p), 32A (4p) II 2G Ex de IIC II 2D Ex td A21 IP66 T80 C RESIDUAL CURRENT CIRCUIT BREAKERS 2p/4p 25/40/63 A, 30 ma, 10 ka with or without auxiliary contact II 2G Ex d e IIC Gb DIGITAL INDIKATOR VEGADIS 175 Ex II 1G EEx ia IIC T6 HRC FUSE, Ex d HOUSING 3p NH00C the base and fuse II 2G Ex de IIC I M2 Ex de I www.tepex.hr 101