Tacho Drive Unit TC-1/ZN2

Similar documents
INTERNATIONAL OIML R 55 RECOMMENDATION

Variable Regulated Voltage Power Supply Instruction Manual Model XP-605 / XP-752A

DIGITAL GEAR INDICATOR

Engineering the Future of Payment Solutions

TECHNICAL MANUAL FOR ELECTRONIC SPEEDOMETER STR-RIEJU MATRIX 2

Superstatic 749. Fluidic Oscillation Compact Heat Meter

FL-100-R (109) Operations and Installation Manual

NOVATEK-ELECTRO LTD Research-and-Manufacture Company. Legat-5M. Voltage Stabilizer. Technical Certificate.

User Manual. CFM/CMM Vane Thermoanemometer. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

User Instruction Manual Oxford Classic Digital Weigh Scale. To avoid injury, read user manual prior to use.

POLE STAR PRO. Installation and instruction manual.

Fluidic Oscillation Compact Heat Meter of High-Tech Composite

Torque Wrenches

Pneumatic Timer. TECHNICAL DATA Display digit roll s, s or s, depending on version Operating pressure 2...

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

CS 420RC. Solid De-icer Controller Configuration and Set-up Manual

SPA MICROPROCESSOR COMBINED TACHO&SPEEDO/GAUGE INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES PAGE 3...OPERATING INSTRUCTIONS

TIMER INTERFACE USER MANUAL

5001TCP SPEED CONTROLLER

EASY CHARGE Waterproof portable Battery Charger

Parts Catalog MIXERS

KONGSKILDE KONNECT 1000

Parts Catalog. Spiral Mixer. Model:

Illustrations. Contents. Burns Connection Head. Models #22, #23 & #24 with Battery Powered LCD Indicator Instruction Manual

MPT-250B SPECIFICATIONS AND OPERATING INSTRUCTIONS

Legat-65. Voltage Stabilizer Technical Certificate. NOVATEK-ELECTRO LTD Research-and-Manufacture Company

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

OPERATION MANUAL. TZ Two Zone Controller

LUBRICATION PUMP PMP CENTRAL LUBRICATION

Instruction of Solar Charge Controller. User s Manual

EM20 Digital Anemometer User Manual

EXHAUST. Crossover Manifold Replacement TX420 & & up. Crossover Manifold Removal

5001TCP SPEED CONTROLLER

Price Computing Scale D Series Operation Manual

Start-up instructions

WARNING. This shows the detail that could lead to death or severe injury if ignored or through misuse the product.


From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

GILTRAP GENERATION II RF CONTROL SYSTEM

Temperature multi-function calibrator Model CTM

Starting System DS-102 Series 200. Elmatik AS P.O.Box 309 NO-3471, Slemmestad T F

Wheel Products. WP8300 Operators Manual Rev: 910

Volt/mA Calibrator. Manual

GENUINE PARTS INSTALLATION INSTRUCTIONS

Clamp-Type Ultrasonic Flow Meter. Specifications. Archive Date Author. Rev / 07 / 30 M.Shiraishi Rev / 11 / 5 M.

NOVATEK-ELECTRO LTD Research-and-Manufacture Company Voltage Stabilizer Legat-15

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual

NOVATEK-ELECTRO LTD Research-and-Manufacture Company Voltage Stabilizer Legat-35

1.Safe testing IMPORTANT:

NEW 15KV HIGH VOLTAGE INSULATION RESISTANCE TESTER MODEL KM 7015 IN FEATURES : CAT IV 600V. Short Circuit Current 5mA.

Measuring. Affordable. Effective. Instruments

OSC is your electric meter expert. When you have questions or need assistance in selecting the proper meter for the job, call us!

Power Inverter 400 MW Owner s Manual

SAC SERIES CONTENTS TRIPLE-INTERVAL HIGH PRECISION COUNTING SCALE OPERATION MANUAL 1. INSTALLATION 2. SPECIFICATIONS

100 Watt Power Inverter + USB INSTRUCTION MANUAL HT8710-AUOXY

STEPPER-BLOCKplus. Manual. Version: 2.0 As of: 06/2002 Author: Edmund Burger &RPSDFW6WHSSHU'ULYHU IRU3KDVH6WHSSLQJ0RWRUV. Main. Status-LED.

Instructions for the BCEA Rotary heat exchanger

Inlet Controller SB3500 USER'S MANUAL

OPERATING MANUAL Digital Diesel Control Remote control panel for WhisperPower generator sets

230VAC Power Inverter 400W Owner s Manual

SERIES 6000 FILM OPACITY METER MODEL RT REV A.1 INSTALLATION & OPERATION MANUAL

D 351 IMPULSE HEAT-SEALER. v.1.5

NLDC-25 Dual Battery Isolator and Charger

CTCII Compact Test Computer II Test and Programming Instructions E-Tacho

LUBRICATION PUMP PMP CENTRAL LUBRICATION

3000 SERIES DRY-BLOCK HEAT SOURCE

Pedelec Operating Instructions Pedelec handleiding Pédélec manuel

DLRO10HDX 10 Amp Digital Low Resistance

User's Manual. Model Hot Wire Thermo-Anemometer. Introduction

Switch select of sender types:

OPERATION & MAINTENANCE MANUAL FOR SCEN-206 LED & MULTI-FUNCTION TYPE CENTRIFUGE PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION.

Declaration of Conformity

OPERATING INSTRUCTIONS MESURES. Portable sludge level measuring instrument, battery operated MES. MUDLine TGS

Hand Held Pull Tester Instruction Manual Order No

How to operate TBC-555L

Glow Plug for E Series Only

Operation Manual. H6000 Series

CONTROL UNIT OMEGA 800-R. User manual

Bio Lion Table Top Centrifuge XC-L5

AZ-8904 THERMO ANEMOMETER

V1.0. Showven Technologies Co.,Ltd.

fax

VZ-01. Features. Oil Counter for Light to Heavy Fuel Oil. Description: Application: / Mounting on pressure or suction side

SCALIX MULTIPURPOSE SCALES SCALIX COMPACT SCALE FKS-600 FKS-6000 INSTRUCTION MANUAL

Stratomaster Smart Single

Time Delta S Fixed Transit-Time Flow Meter System

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

Solar Controller SUNGO S

ERROR CODES BIKES CROSS TRAINING

User Guide. Lubricus Lubrication System LUB-D1/LUB-D2/LUB-D3/LUB-D4 (24 VDC)

Fluidic Oscillation Compact Heat Meter

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

Repair instructions UNIVERSAL 320 UNIVERSAL 320 R Andreas Hettich GmbH & Co. KG AR1401EN

Ultra 5.0 Manufactured By Hanil Science Industrial Co., Ltd. In Korea

Activator 282 Aircraft Battery Maintenance Charger Operator Manual

Model : LHT-002A Please read this manual carefully before using the instrument Labnics Equipment

VECTRIX VX-2 SERVICE MANUAL. Version 1.0/May 2011 VECTRIX, LLC

CS 430RC. Solid De-icer Controller Configuration and Set-up Manual

MFM300 Plastic-Bodied Magmeter

Transcription:

Tacho Drive Unit TC-1/ZN2 User manual

Zespół napędowy TC-1/ZN2 jest przyrządem kontrolno-pomiarowym przeznaczonym Motor drive unit TC-1/ZN2 is a measuring and control instrument designed for the check-out of vehicles tachographs. Motor drive unit TC-1/ZN2 can be used as an individual mechanism, likewise it can get along with Tachotester TC-1. METROLOGICAL TECHNICAL DATA: Range of changes constant Sn : 500...2000 rev/km Value of elementary scale: 1 rev/km Range of changes in linear vehicle velocity mechanism: for Sn= 500 rev/km: 3,6...250,0 km/h for Sn= 625 rev/km: 2,9...250,0 km/h for Sn=1000 rev/km: 1,8...250,0 km/h for Sn=2000 rev/km: 0,9...125,0 km/h Value of elementary scale: 0,1 km/h Permissible boundary error: for speed in range up to 20,0km/h: ± 0,05 km/h for speed in range 20,0...180,0km/h: ±0,25% normal value Range measurement of Road length: 0,001...99999,999 km Value of elementary scale: 1 m Permissible boundary error: ±1 m Range measurement of revolution s number: 1...99999999 rev Best resolution: 1 obr Accuracy: ±1 obr Tachograpch s Power supply : 12V i 24V Maximum load of electric current: 1,5A Operating temperature: 0...+50 o C Dimensions: 265 x 230 x 150 mm Weight: 6,9kg Power: requirements: 220V 50Hz Power consumption: 120W Description : Impulsive unit TC-1/ZN2 is placed in metal case and equipped with an electrical engine which is stabilized by a microprocessor, an LCD display, a multipurposes button, a signal socket which enables the connection with Tachotester TC-1 and a stabilized supplier +12/+24V to supply the tachographs during their check-out. This instrument is supplied by alternate electric current 220-240V/50-60Hz. The ending of the driving shaft corresponds to the standard flipper with thread M22x1,5. 2

7 9 1 2 8 3 4 5 6 Pict.1. Front view 10 Pict.2. Side view 3

11 12 1 Power supply switch 2 Power LED 3 Power supply terminal (negative) 4 Power supply terminal (12V positive) 5 Power supply terminal (24V positive) 6 Control socket 7 Multipurpose knob 8 Button 9 LCD display 10 Driving Shaft 11 Power supply connector 12 Fuse 1Ampere Pict.3. Back view 4

Instructions: Turn the Power supply switch (1) and the following message will be displayed on the LCD screen (Pict.4): Pict.4. In this case the multipurpose knob (7) is able to control the contrast of the display. The active signal socket enables to operate the driving unit through Tachotester TC-1. Every information and measurements dealing with the movement of the driving shaft are displayed on the LCD screen while Tachotester TC-1 is working. You can only change the contrast of the screen: Pict.5. Pressing button (8) will stop the transmission through the signal socket. Then, driving unit switches to individual functioning. However, if the button is pressed longer than 0,8 sec., the setup options for constant Sn will start: Pict.6 The value of the constant Sn, within the range of 500 to 2000, can be set with the multipurpose knob (7). It is also possible to use the multipurpose button to be more accurate. 5

Pict.7 A short press of the button (8) (less than 0,8sec.) will cause the record in the memory of the constant Sn and pass to the set up of the driving shaft s speed. After turning the power supply on, a quick press of the button also leads to this. (pict. 4) Pict.8 Multipurpose knob (7) sets up applicable speed of the driving shaft. The display will show the following values : Sn speed constant expressed in rev/km v- linear speed expressed in km/h n- number of revolutions expressed in rev. l- road length Pict.9 The reset of the revolution and road length counter is caring out by a short press of the button (8). The counter proceeds independently and irrespective of the current speed of the driving shaft. Pict.10 6

A long (over 0,8sec.) press of the button (8) stops the driver and leads back to the initial state of the instrument (after turning on) (pict.4). At the same time, the transmission with the Tachotester TC-1 is unblocked by the signal socket (6). Pict.11 STORAGE AND PRESERVATION: It is necessary to keep the driving unit TC-1/ZN2 in a dry place where there is no dust or high temperatures and away from the sun rays. TC-1/ZN2 needs no special preservation except a regular cleaning. To clean the impulsive unit TC-1/ZN2 use only soft, little moist cloth to prevent any damage such as scratches on the display or flood of the instrument s inside. EQUIPMENT: 1. Impulsive unit 2. Power cable 3. Instructions 7