EGT-100 Operations and Installation Manual

Similar documents
FP-100 Fuel Pressure and Ammeter Indicator Page 1 of 16. All specification subject to change Aerospace Logic Inc.

FL-100-R (109) Operations and Installation Manual

This document set is applicable to the following part number configurations:

βeta 20A AUTO 12V/24V SOLAR CHARGE CONTROLLER WITH REMOTE METER

TTT802 Gearshift Controller, Part # R1N-S (Standard), -P (Paddleshift)

Automotive Application ET01 Software Revision A 12/06

ECT Display Driver Installation for AP2 Module

Dual Voltage Solar Power Charge Controller Board Connection & Operation V2.xx

ODYR-25-1 & SLX-25-1 rev. A VACUUM/BOOST PRESSURE, TEMP, and EGT GAUGE

Sól Dual Voltage Buck Boost Solar Charge Controller Connection & Operation V1.00

SPA MICROPROCESSOR 3 STAGE PROGRAMMABLE SHIFT LIGHT INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES. PAGE 3...INSTALLATION NOTES.

Lycoming Engine Sender Installation Guide

ATOTH-G Series BLDC Motor Controller. User s Manual

INSTALLATION GUIDE Chevrolet Digital Dash Panel Part Number: DP6003 Year Series:

CONTROLLER DIAGNOSTIC GUIDE

EMS-2. Introduction. Features. Engine Management System. Operating Manual English 1.07

Blaze TC-6. Introduction. 1 Features. Twelve channel thermocouple (EGT/CHT) indicator. Operating Manual English 1.00

Part Number AEM 4-CH WIDEBAND UEGO CONTROLLER

Temperatures can be displayed in degrees Celsius or degrees Fahrenheit from -100ºC to 1200ºC (-148ºF to 2192ºF).

SPA MICROPROCESSOR COMBINED TACHO&SPEEDO/GAUGE INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES PAGE 3...OPERATING INSTRUCTIONS

The TC-4 is a 2 1/4 sunlight readable 4 channel thermocouple color display instrument.

Brushed. Brushed. Brushed Motor

Automatic Transfer Switch FT-10 Network Control Communications Module (CCM-T) Kit

SPA MICROPROCESSOR 3 STAGE PROGRAMMABLE SHIFT LIGHT INSTALLATION AND OPERATING MANUAL PAGE 2...INSTRUMENT FEATURES. PAGE 3...OPERATING INSTRUCTIONS.

BAPI-Stat 3 Room Sensor

Model 7400 OPERATOR MANUAL

GENERAL INFORMATION. H-1649, H-1650, H-1651 H-1653, H-1654 Easy-Count. uline.com. that may hurt accuracy:

Stratomaster Smart Single

S D ST215 TAFFOR. ST215 Temperature Programmer User Handbook.

Instruction Manual. Digital Panel Meter Model 3126 CAUTION. Code Type of T/C Measuring Range Display Range Accuracy

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

GENERAL The AuRACLE Engine Management System primary display provides a graphical representation of the following engine instrumentation:

Installation Instructions for: Channel Thermocouple Amplifier

Part Number Analog EGT Gauge

ISO-9001:2008 HOT PLATES CATALOG. Phone: Fax: Web:

FLEC AIR PUMP Operators Manual JULY QUI-1030 VERSION 1.2

Model 8000XL OPERATOR MANUAL

ST315B. User Handbook STAFFOR. ST315B Temperature Programmer. See separate handbook for Installation Instructions Issue: 2.00

PO Box 2484 Rowville Vic 3178

ITA / ITB - AS / AP / AP SERIES Electronic Table Top Weighing Balance

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

MGL Avionics EFIS G2 and iefis

Kelly KDC Series/PM Motor Controller User s Manual

Part Number DP6003 Chevy Truck Digital Dash YEARS 67-72

UNIVERSAL CALIBRATOR M

Harris IRT Enterprises Digital Resistance Tester Model XP

Installation & Calibration

MAGPOWR Spyder-Plus-S1 Tension Control

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

Inlet Controller SB3500 USER'S MANUAL

ALM LSU ADV Manual. Accurate Lambda Meter With built-in LED display COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

Fuel Flow / Pressure (FP-5 and FP-5L) Operating Instructions

Dusty / Dusty Ex. Low-Cost Broken Bag Detection. Operating Instructions. SWR engineering Messtechnik GmbH

PROFIRE 1100i IGNITION FLAME SAFETY CONTROLLER

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

ELECTRONIC TRACTION CONTROL USER MANUAL

Thermocouple Thermometer Models

DLRO 10 and DLRO 10X. Digital Microhmmeter. DLRO 10 and DLRO 10X Digital Microhmmeter. NEW interchangeable test lead terminations

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Generator Set Applications FT-10 Network Control Communications Module (CCM-G) Kit

Pilot's Operating Handbook Supplement AS-03

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Part No EWP & FAN DIGITAL CONTROLLER INSTRUCTIONS

Advanced Power Pack SP Operating Instructions

SLC Pure Plus 2.1 User Manual

CeraControl. Temperature Programmer User Handbook.

Operating Manual OBD Link Connector

OMEGA KUSTOM INSTRUMENTS

Kelly KDHA High Voltage Series/PM Motor Controller User s Manual

HI Ethylene Glycol Refractometer INSTRUCTION MANUAL


1.0 Features and Description

Kelly HPM High Power Full Bridge Permanent Magnet DC Motor Controller User s Manual

RD712 & RD712XL Remote Displays. Model 615 / 615XL Indicator User s Manual

MATRIX LLC LEVEL CONTROL PANEL

SECTION Instrument Cluster and Panel Illumination

JUMO thermocor. Portable measuring system for AMS2750 and CQI-9. Brief description. Block diagram. Special features. JUMO thermocor.

Full Bridge Permanent Magnet DC Motor Controller User's Manual

TECHNICAL PRODUCT DATASHEET

Paraffin Dispenser Catalog # PD-120, PD-220 Operator s Manual Version 1.5b, Jan 2007

Wind display type WSDI-2

CLA-VAL e-drive-34. User Manual. Motorised Pilots. CLA-VAL Europe LIN072UE - 04/16

Instruction of connection and programming of the VECTOR controller

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

ALFA-Club. Owners Manual Rev 4.0, August Small Systems Specialists 201 N. Lobb Ave. Pen Argyl, PA Memory Checkpoint Clock

SP Switch Programmable Switch Panel Power System. Parts Included

Description of the AMT Netherlands Olympus HP gas turbine.

SmartLock Fifth Wheel

Combined Ventilation Controller RVWS-T-224HA

Application. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203)

Instruction of Solar Charge Controller. User s Manual

8000 Series Liquid Flow Meters

INTERNATIONAL METAL ENGINEERING

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

Installation and User Manual. with RAIN SENSOR.

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

Effective March 1, 2018

GTWY505 Fast Idle, Shift Interlock, I/O Ford E-Series

ALM-Inline. Accurate Lambda Meter V1.1.2 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

Transcription:

Page 1 of 11 All specification subject to change 2002-2005 EGT-100 Operations and Installation Manual This manual is certified for use with instrument serial number ASL000000 Use of this manual with any other instrument voids all warranties and may result in damage to the instrument THIS IS A TRANSPORT CANADA APPROVED MANUAL READ THIS FIRST Congratulations on the purchase of your EGT-100 Exhaust Gas Temperature Indicator. This instrument is a complex precision instrument manufactured to exceed Airborne Equipment Standards DO-160D, DO-178B and TSO C43c standards. In order for your instrument to function correctly you will need to review the instructions in this brief manual. This document covers the following instrument models: EGT-100-4 4 Cylinder EGT EGT-100-4V 4 Cylinder EGT with Voltmeter EGT-100-6 6 Cylinder EGT EGT-100-6V 6 Cylinder EGT with Voltmeter

Page 2 of 11 1. Introduction Your EGT-100 Exhaust Gas Temperature Indicator will provide you with years of reliable service and generally outlast the life of your aircraft. The instrument is constructed from the highest quality components and has a design life in excess of 100,000 hours. It is the most reliable instrument of its kind. Gone are the days of questioning the accuracy or operation of the instrument. No stuck needles, erroneous readings or instruments that keep you guessing as to their operational status. Every reading you will see displayed on your instrument has been validated at least 256 times before you see it. This all happens in less than a second. When you see the result you know the instrument is functioning correctly as it is monitored by an independent microprocessor just to ensure that it is functioning correctly. In turn the main processor validates the independent monitoring processor. Any failure detected in either processor and your instrument display will be shut down or an error message displayed depending on the failure status. 2. Display The main display of the instrument displays a graphical representation of the temperature of the selected cylinder on the bar display, provided the temperature is within the defined limits set by the user. The lower four-digit seven-segment display provides a mathematically computed display of the specific temperature. The A M S switch allows you to select the various functions of the instrument. When the switch is placed in the A position the instrument is placed in the AUTOMATIC mode. In this mode it will select and display the information for the hottest cylinder. When in the M position the instrument allows MANUAL selection of the function of choice. Available functions are: STEP, 1, 2, 3, 4, 5, 6, (5 and 6 only available on 6 cylinder models) where the numbers correspond to the cylinder number to be monitored. In the STEP mode the instrument will sequentially step through all cylinders. Moving the A M S switch momentarily to the S position will allow movement between the manually selectable pages.

Page 3 of 11 3. Installation Ensure that the thermocouple probes have been installed PRIOR to installing the instrument. See Probe Installation for full details (Section 6). The EGT-100 will fit any standard 2 ¼ aircraft mounting hole. Place the instrument in the hole from the rear of the panel and then attach it with the four screws provided. If you need to replace the screws, ensure that the threads do not penetrate the instrument more than ½. Screws that penetrate the instrument further will cause severe damage to the instrument. WARNING This instrument is a highly sensitive and accurate instrument, however without proper wiring and connections it is possible to induce temperature reading errors. Please read and follow all instructions carefully to ensure proper operation. The instrument has been software calibrated and never needs recalibration provided no wiring modifications are made at installation time. Now connect the supply and dimmer wiring. These wires may be trimmed to any desired length. RED BLUE WHITE Master switched 14/28V bus (Instrument is internally fused) 28V Dimmer control (if required) 14V Dimmer control (if required) NEXT CONNECT THE BLACK WIRE TO A GROUND POINT ON THE ENGINE BLACK Aircraft supply ground connected on engine ground point. Wherever possible ensure that connection to the probe ends is made on the cockpit side of the firewall. If this is not possible ensure that the junction between the signal wiring from the instrument and the probe is in the coolest possible location in the engine compartment. Next connect the probe signal wiring. These wires are the red/yellow twisted pairs. Each cylinder is identified by a color tag on the specific twisted pair. Do NOT un-twist these cable pairs. They are designed to reduce signal noise. Do NOT trim the thermocouple probe wires under any circumstances. Where possible do NOT strap the signal wiring to other aircraft wiring. Trim these wires to length if necessary, but do not remove the color code tags.

Page 4 of 11 Thermocouple signal cables are red/yellow twisted pairs. The colors listed refer to the tag color on the wire pair. Green and yellow tags are only on 6 cylinder instruments. BLACK Cylinder 1 BLUE Cylinder 4 RED Cylinder 2 GREEN Cylinder 5 WHITE Cylinder 3 YELLOW Cylinder 6 If you have purchased a complete instrument and probe kit appropriate connectors for interconnection of the signal wires and probe leads are provided. If you have purchased only the instrument NO connectors are provided as there is no way of determining what type of probes will be used. In this case the installer is to provide the necessary connectors. WARNING! TSO and STC certifications for this instrument will be void if it is used in conjunction with NON-TSO d thermocouples! See Specifications for requirements. For installation of the complete kit, simply snap the connectors together for the appropriate cylinders, slide the included heat shrink sleeves over the connection and shrink to size. Take care in matching the correct color coded signal pair to the correct cylinder.

Page 5 of 11

Page 6 of 11 4. SETUP Once installed your instrument will require setup to match the specific engine parameters as well the user defined preferences. Instrument setup is only required when a parameter or display configuration is to be changed. With proper planning you should only have to perform this function once in the life of the instrument. All information is stored in the instruments lifetime memory, which will be retained without battery power for up to 100 years. To enter SETUP mode turn off all power to the instrument. Next press and HOLD the A M S switch in the S position and turn on the power to the instrument. Hold the switch in this position until SEt- is displayed. At this point release the switch. NOTE: When in the setup mode the display bar will remain blank. The CYL digit and the four digit display shows the parameter value and type as per the enclosed instructions. In order to set the manufacturer specified limits for your engine you will require the manufacturer specified high and low limits. Please refer to your engine operator s manual for this information. Most engines will operate between 1300ºF and 1600ºF. CyLS (Cylinder Count Selection) For a 6 cylinder instrument, moving the A M S switch to the A position and back to the M position will allow selection between 4 and 6 cylinder operation. For a 4 cylinder instrument, no choice of cylinder count is available. Simply move the A M S switch once to the S position and release. The 4 cylinder configuration will now be saved and the display will move to the next parameter. Int (Intensity Source Selection) Moving the A M S switch to the A position and back to the M position will allow selection between I (internal intensity control) or E (external intensity control). Select the appropriate intensity source and move the A M S switch once to the S position and release. The intensity source will now be saved and the display will move to the next parameter.

Page 7 of 11 L (Low Temperature Limit Set) The low temperature limit should be set to the manufacturers recommended low limit for correct operation. This setting determines the point at which the bar indicator will begin to turn on. Values for this setting can range from 1000º to 1600ºF. Moving the A M S switch to the A position and holding it there will allow the temperature to increment. Initially the increment will be at a slow rate and then speed up to a faster rate for easy selection. Once the increment is in the fast mode it can be slowed again by moving the A M S switch once to the M position and then back to the A position. Once the maximum (1600ºF) has been reached the count will start over at 1000ºF. Once the correct temperature has been reached, by moving between the A and M positions of the A M S switch, move the A M S switch once to the S position and release. The low limit will now be saved and applied to all cylinders. The display will move to the next parameter. H (High Temperature Limit Set) The high temperature limit should be set to the manufacturers recommended high limit for correct operation. This setting determines the point at which all bars on the bar indicator will turn on. Values for this setting can range from the low limit plus 20ºF to 1800ºF. Moving the A M S switch to the A position and holding it there will allow the temperature to increment. Initially the increment will be at a slow rate and then speed up to a faster rate for easy selection. Once the increment is in the fast mode it can be slowed again by moving the A M S switch once to the M position and then back to the A position. Once the maximum (1800ºF) has been reached the count will start over at the preset low limit plus 20ºF. Once the correct temperature has been reached, by moving between the A and M positions of the A M S switch, move the A M S switch once to the S position and release. The high limit will now be saved and applied to all cylinders. DonE The display will now show the characters DonE and the instrument will restart. At this point you have completed all the setup and configuration of the instrument and it is ready for service.

Page 8 of 11 5. Operation Once power is applied to the instrument it will display the model number and a test message with the complete display lit. Immediately following this it will display the temperature information and default to the STEP mode. MANUAL MODE In the manual mode (A M S switch in the M position) movement between the different manually selectable functions is achieved by moving the A M S switch once to the S position and then releasing it. The order of display is: STEP Sequentially displays each cylinder temperature for 5 seconds. In the STEP mode the instrument will display the STEP message for approximately five seconds before starting the step process. Once started it will step through all cylinders. When the last is reached, it will revert back to the first. 1 Display temperature information for cylinder 1 2 Display temperature information for cylinder 2 3 Display temperature information for cylinder 3 4 Display temperature information for cylinder 4 For 6 cylinder instruments two additional displays are: 5 Display temperature information for cylinder 5 6 Display temperature information for cylinder 6 For instruments with the optional voltmeter function: v Displays line voltage present on the instrument supply bus If the internal intensity option has been selected: ^ Increase intensity Moving the A M S switch to the A position will increase the brightness of the display. Move the switch back to the M position when the desired brightness is reached. v Decrease intensity To decrease the brightness move the A M S switch to the A position. Move the switch back to the M position when the desired brightness is reached.

Page 9 of 11 If the instrument is left in the intensity mode without any changes for more than eight seconds it will revert to the last selection. We recommend the use of the internal intensity control for the most accurate control of the brightness of the instrument. AUTOMATIC MODE Moving the A M S switch to the A position will place the instrument in the automatic mode. In this mode it will select and display the temperature for the hottest cylinder. All cylinders are scanned in less than one second and the display updated at the same rate. This mode of operation is the single most important feature of this instrument and should be used during leaning and normal operations. Leaning in the automatic mode ensures that no cylinder is overheated during the process. If the instrument is switched from the automatic mode back to the manual mode it will revert to the last selected manual function. For complete leaning instructions and limits refer to your engine manufacturers recommended procedures, then select the AUTO mode for a hassle free leaning process. DISPLAY The bar display will display a graphic representation of the selected cylinder temperature between the defined low and high limits. Each bar represents 1/10 of the temperature range between the low and high limits. For temperatures in excess of the high limit the two upper bars (red bars) will blink. Once the temperature cools and is within the limits the blinking will cease. The over temperature blinking does not occur in the STEP mode. Temperatures below the low limit will only be displayed on the four digit display. If the temperature is below 200ºF the display will read COLd. As soon as the temperature exceeds this limit it will be displayed.

Page 10 of 11 6. Probe Installation NOTE: This section refers primarily to installation of probes supplied as a kit with the specific instrument. For installation using existing or owner supplied probes please see the specific probe manufacturer information. The instrument will support all grounded and ungrounded probes that meet the requirements listed in the Specification Section. Thermocouple / Signal Wire Junction Where possible, plan the installation such that the junction between the thermocouple and signal wire takes place on the cockpit side of the firewall. If this is not possible ensure that the junction is in the coolest possible location in the engine compartment. Ensure that ALL thermocouple leads are strapped together at the junction point. This will further eliminate the possibility of any ground loop problems. Connection Thermocouple leads are marked with red (negative) and yellow (positive) sleeves and match the corresponding red and yellow twisted pair signal wires. Simply snap the corresponding connections together, slide the heat shrink sleeve over the junction and shrink to size when installing the instrument. For installation of the probe end into the exhaust please see the illustration as below:

Page 11 of 11 7. EGT-100 Specifications Dimensions: Fits standard 2.25 mounting hole 2.45 X 2.45 X 1.6 2 viewing area Weight: 10oz (4 cyl.) / 13oz (6 cyl.) Display Custom design color bar display Multi-color sunlight visible InGaAIPGaN LED technology 100,000 hours operating life Analog and digital readout of temperatures Maximum Ranges 0ºF 1900ºF. Displays 200ºF 1900ºF as actual temperature and 0ºF 199ºF as COLD Voltmeter: 6.0v to 32v (optional) Accuracy 1% of range per TSO (SAE AS8005 Class IIa instrument classification) Voltmeter: 1/10 Volt over full operating range Safety Color coded temperature values Visual high temperature alarms for each cylinder Dual processor monitoring with one second error shutoff Internal over temperature shutoff Floating point mathematical compensation for thermocouple sensor linearity Minimum 256 times measurement validation before display Operating Temperature -15ºC to +55ºC 5ºF to 131ºF Power Consumption 370mA Max (daytime operation) 50mA Min (nighttime operation) Display Pages/Functions AUTO automatically select and display hottest cylinder. One second scan rate for 4/6 cylinders STEP sequentially step through each cylinder with five second intervals 1 4/6 manually select and display any cylinder information High limit alarms (visual) Integrated voltmeter (optional) Two brightness selection pages (internal intensity selection) Intensity Control Programmable user option External using rheostat type dimmer Internal selection programmable from the front panel 256 level of brightness Linearity Mathematical compensation over the full operating range Operating Voltage 6V-32V DC Thermocouples Supported ONLY TSO d thermocouples that possess the following characteristics: Recommended type Westach series 713 EGT probes. Type K with outputs as listed: 200ºF 2.87mV 400ºF 7.36mV 800ºF 16.58mV 1000ºF 21.31mV 1200ºF 26.03mV 1400ºF 30.70mV 1500ºF 32.90mV 1600ºF 35.24mV 1800ºF 39.67mV Display Units ºF temperature Volts voltmeter (optional) All specification subject to change 2002-2005