MEDIUM DUTY DOOR OPERATOR MODELS MJ5011U, MH5011U, MHS5011U, & MGJ5011U

Similar documents
MEDIUM DUTY DOOR OPERATOR MODELS MJ5011U, MH5011U, MHS5011U, & MGJ5011U

MEDIUM DUTY DOOR OPERATOR MODELS MT5011U & BMT5011U

LMPLC EES SERIES COMMERCIAL/INDUSTRIAL DUTY EGRESS DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY LMPLC CONTROL NOT FOR RESIDENTIAL USE.

Logic 5.0 Commercial Door Operator INSTALLATION MANUAL

INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR

Photoelectric. Sensors Invisible Light Beam Protection Area

FDO AU & BU LMPLC ADVANCED LOGIC COMMERCIAL/INDUSTRIAL DUTY DOOR OPERATOR. B2/C2 Wiring

OWNER S MANUAL MODEL NO. MEDIUM DUTY JACK SHAFT OPERATOR MDJ, MDJH, MDJB, MDJBH READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS SAVE THESE INSTRUCTIONS

HAZARDOUS (NEMA 7/9) INDUSTRIAL DUTY COMMERCIAL DOOR OPERATOR 2 YEAR WARRANTY. Serial # Box. Installation Date. Wiring Type

For more information: or call toll free at

FDO AU AND BU LMPLC ADVANCED LOGIC COMMERCIAL/INDUSTRIAL DUTY DOOR OPERATOR. B2/C2 Wiring

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Chain Drive Garage Door Opener Model 8360 FOR RESIDENTIAL USE ONLY

Installation Manual. Models

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

Installation Manual. Model 8155

GARAGE DOOR OPENER Model 3800

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

PREMIUM Series 1/2 hp Chain Drive Garage Door Opener

Wi-Fi Garage Door Opener

Models. ELITE Series Garage Door Opener CONTENTS DC Belt Drive with Battery Backup /4 hp Belt Drive FOR RESIDENTIAL USE ONLY

3/4 hp Belt Drive Garage Door Opener. Model HD620EV

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

CONTENTS. 3/4 hp Belt Drive Garage Door Opener. Model HD630EVP FOR RESIDENTIAL USE ONLY

Owner s Manual C205. Garage Opener. Contents. Chain Drive Garage Door Opener FOR RESIDENTIAL USE ONLY PRE-PROGRAMMED REMOTE CONTROL INCLUDED

Wi-Fi Garage Door Opener

Wi-Fi Garage Door Opener

/ / Preparation. Safety Symbol and Signal Word Review. MyQ Serial Number. Unattended Operation. MyQ Serial Number: Product S/N: Date of Purchase:

GARAGE DOOR OPENER Model 3840

3/4 hp Chain Drive Garage Door Opener. Model PD752KEV

DELUXE Series Chain Drive Wi-Fi Garage Door Opener

CONTENTS. Chain/Cable Drive DC Garage Door Opener. Model 8010 FOR RESIDENTIAL USE ONLY INSTALL ON 7 OR 8 FOOT SECTIONAL DOORS ONLY

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

WARNING: To reduce the risk of injury to persons - Use this operator only with Residential Sectional Garage doors.

Model 8587WRGD Chain Drive Garage Door Opener

COMMERCIAL 24VDC HIGH TRAFFIC OVERHEAD DOOR AND GATE OPERATOR WITH BATTERY BACKUP INSTALLATION MANUAL

PREMIUM Series Chain Drive Garage Door Opener

Model 3800PC GARAGE DOOR OPENER For Residential and Light Duty Commercial Use Install On Sectional Doors With Torsion Assemblies Only

INSTALLATION AND INSTRUCTION MANUAL MODELS: PRO-T, PRO-TB

New! GARAGE DOOR OPENER Model 3500D. Owner s Manual. For Residential Use Only

GARAGE DOOR OPENER. Owner s Manual. Model 1280RGD 1/2 HP. For Residential Use Only

Owner s Manual C455. Smart Garage Opener. Contents. Chain Drive Garage Door Opener FOR RESIDENTIAL USE ONLY PRE-PROGRAMMED REMOTE CONTROL INCLUDED

1/2 hp Chain Drive Garage Door Opener. Model HD420EVP FOR RESIDENTIAL USE ONLY

USER S GUIDE MODEL WLED. ELITE Series LED Wi-Fi Garage Door Opener FOR RESIDENTIAL USE ONLY

EXTREME R MOTOR OWNER'S MANUAL

GARAGE DOOR OPENER. Owner s Manual. Series CG40 1/2 HP. For Residential Use Only

GARAGE DOOR OPENER. Model M375-1/2HP. Owner s Manual. For Residential Use Only

SKC400U SLIDING GATE OPENER OWNER S MANUAL

Owner s Manual B970. Smart Garage Opener. Contents. Belt Drive Garage Door Opener FOR RESIDENTIAL USE ONLY PRE-PROGRAMMED REMOTE CONTROL INCLUDED

LMPLC COOKSON OWNER'S MANUAL FDO A & B SOLID STATE INDUSTRIAL DUTY FIRE DOOR OPERATOR. B2/C2 Wiring 2 YEAR WARRANTY FDO 1/2 HP FDO A & B

Belt Drive Battery Backup Garage Door Opener Models HD920EV WD962KEV WD962KPEV

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

GARAGE DOOR OPENER ASSEMBLY/ INSTALLATION MANUAL

Model HD750WF CONTENTS. 3/4 hps * Belt Drive Garage Door Opener with FOR RESIDENTIAL USE ONLY

GARAGE DOOR OPENER Model /2 HP

Please read and understand this manual and safety instructions carefully before installation.

Owner s Manual B980. Smart Garage Opener. Contents. Belt Drive Garage Door Opener FOR RESIDENTIAL USE ONLY PRE-PROGRAMMED REMOTE CONTROL INCLUDED

GARAGE DOOR OPENER. Series /2 HP. Owner s Manual. For Residential Use Only

GARAGE DOOR OPENER Model 3595LM 3/4 HP

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

SAFE AND SECURE EXTREME R MOTOR OWNER'S MANUAL MODEL PRO-FDG FOR TECHNICAL SUPPORT PLEASE CALL 1-(855) OPERATOR SERIAL#

COOKSON OWNER'S MANUAL

GARAGE DOOR OPENER Model /4 HP

FUNCTION: Allows existing Logic Control Version 2.0 or 2.0 Rev. B board in field to be replaced with new Logic Control Version 2.0 Rev. B.

Models HD920EV HD930EV LW5000EV WD962KEV WD962KPEV WD962MLEV

Owner s Manual GARAGE DOOR OPENER. Series PD200 1/2 HP. For Residential Use Only

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL

WARNING: To reduce the risk of injury to persons - Use this operator only with Residential Sectional Garage doors.

GARAGE DOOR OPENER Model HD200D 1/2 HP

Feature Overview. For more information: or call toll free at

WARNING: To reduce the risk of injury to persons - Use this operator only with Residential Sectional Garage doors.

GARAGE DOOR OPENER Model HD200DM 1/2 HP

USER S GUIDE. Wall Mount Wi-Fi Garage Door Opener. Model 8500W

OWNER'S MANUAL MODEL GH 5HP HEAVY DUTY DOOR OPERATOR 2 YEAR WARRANTY. Serial # (located on electrical box cover) Installation Date.

COMMERCIAL DOOR OPENER Model ATS 2113X-CX 1/2 HP

GARAGE DOOR OPENER OWNER S MANUAL S3/S4

MJ3800. Residential & Light Duty Commercial Door Opener. Installation and Operating Instructions

GARAGE DOOR OPENER Model /4 HP

MODELS MC100, MC100C, MC100-P2 AND MC100C-P2 Universal Mini Remote Control

MODEL MG Gearhead Operator

GARAGE DOOR OPENER Series WD822K 1/2 HP

GARAGE DOOR OPENER Models /3 HP /2 HP /2 HP

GARAGE DOOR OPENER Model M385M - 1/2 HP

INSTALLATION AND OWNER S MANUAL MODEL T Trolley Operator

Safety Precautions Assembly Installation Adjustment Care and Maintenance Operation Troubleshooting Parts List

GARAGE DOOR OPENER Model

ControlHoist Standard

GARAGE DOOR OPENER Model HD600 1/2 HP

Please read this manual and the enclosed safety materials carefully! Periodic checks of the opener are required to ensure safe operation.

GARAGE DOOR OPENER Model /2 HP

Owner s Manual. GARAGE DOOR OPENER Model S 3/4 HP. For Residential Use Only

GARAGE DOOR OPENER Model 3585S 3/4 HP

INSTALLATION AND OWNER'S MANUAL Model GJ & MGJ Gear Reduced Jackshaft

GARAGE DOOR OPENER Models WD822KD WD832KD /2 HP

GARAGE DOOR OPENER Model /2HP

INSTALLATION M ANUAL

GARAGE DOOR OPENER Models 3240M 1/2 HP 3130M 1/3 HP. Owner s Manual. For Residential Use Only

Transcription:

MEDIUM DUTY DOOR OPERATOR MODELS MJ0U, MH0U, MHS0U, & MGJ0U INSTALLATION MANUAL Now with Built in Radio Receiver MHz Your model may look different than the model illustrated in this manual. YEAR WARRANTY Serial # (located on electrical box cover) Installation Date THIS PRODUCT IS TO BE INSTAL AND SERVICED BY A TRAINED DOOR SYSTEMS TECHNICIAN ONLY. Visit LiftMaster.com to locate a professional installing dealer in your area. OPERATOR RATING: cycles per hour, 0 cycles per day; maximum NOT FOR RESIDENTIAL USE

TABLE OF CONTENTS SAFETY INFORMATION APPLICATION OPERATOR SPECIFICATIONS - Weights and Dimensions................... Motor............................. Mechanical........................... Electrical............................ Safety............................. Environmental......................... CARTON INVENTORY PREPARATION Preparing Your Door...................... Handing Identifi cation..................... ASSEMBLY TYPICAL INSTALLATION 8- Determine Mounting Location for Operator.......... 8 Install the Operator..................... 8-9 Install Emergency Disconnect System.............0 Power and Ground Wiring Connections.......... - Install -Button Control Station.............. - Setup Radio Antenna................... - ADJUSTMENT Adjust the Limits........................ Adjust the Clutch........................ ENTRAPMENT PROTECTION -9 LiftMaster Monitored Entrapment Protection (LMEP)..... Install the Photoelectric Sensors................ Mount the Photoelectric Sensors...............8 Entrapment Protection Wiring Options.......... 8-9 LOGIC BOARD LAYOUT 9 BASIC PROGRAMMING 0- Determine the Wiring Type................ 0- Remote Controls...................... - Timer-to-Close ()................... - TESTING EMERGENCY DISCONNECT TROUBLESHOOTING - DIAGRAM ACCESSORIES CONTROL CONNECTION DIAGRAM BACK COVER

SAFETY INFORMATION Mechanical Electrical When you see these Safety Symbols and Signal Words on the following pages, they will alert you to the possibility of serious injury or death if you do not comply with the warnings that accompany them. The hazard may come from something mechanical or from electric shock. Read the warnings carefully. When you see this Signal Word on the following pages, it will alert you to the possibility of damage to your door and/or the door operator if you do not comply with the cautionary statements that accompany it. Read them carefully. IMPORTANT NOTES: BEFORE attempting to install, operate or maintain the operator, you must read and fully understand this manual and follow all safety instructions. DO NOT attempt repair or service of your commercial door and gate operator unless you are an Authorized Service Technician. WARNING: This product can expose you to chemicals including lead, which are known to the State of California to cause cancer or birth defects or other reproductive harm. For more information go to www.pwarnings.ca.gov IMPORTANT INSTALLATION INSTRUCTIONS WARNING To reduce the risk of SEVERE INJURY or DEATH:. READ AND FOLLOW ALL INSTALLATION WARNINGS AND INSTRUCTIONS.. Install door operator ONLY on properly balanced and lubricated door. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.. ALL repairs to cables, spring assemblies and other hardware MUST be made by a trained door systems technician BEFORE installing operator.. Disable ALL locks and remove ALL ropes connected to door BEFORE installing operator to avoid entanglement.. Install door operator 8 feet (. m) or more above fl oor.. NEVER connect door operator to power source until instructed to do so.. NEVER wear watches, rings or loose clothing while installing or servicing operator. They could be caught in door or operator mechanisms. 8. Install control station: within sight of the door. out of reach of children at minimum height of feet (. m). away from ALL moving parts of the door. 9. Install the control station far enough from the door to prevent the user from coming in contact with the door while operating the controls. 0. Install the entrapment warning placard on wall next to the control station in a prominent location that is visible from the door.. Place manual release/safety reverse test label in plain view on inside of door.. Upon completion of installation, test entrapment protection device.. This door operator is not intended to replace door locks. With enough force, a door without a door lock can be opened. LiftMaster always recommends the use of door locks to properly secure a door.. SAVE THESE INSTRUCTIONS.

APPLICATION This operator includes a number of features that will provide years of reliable and safe operation. FEATURES: Supports both monitored and non-monitored entrapment protection devices: Entrapment protection devices detect obstructions in the door's path and automatically reverse a closing door. Radio receiver: A factory installed radio receiver allows remote controls, keyless entries and other remote command devices to be programmed to the operator. Timer-To-Close: The Timer-to-Close feature allows the door to automatically close after a preset time (only available with B wiring and a monitored entrapment protection device). Wiring Types: The functionality of the operator is based on the wiring type. The operator is shipped from the factory in standard C wiring type (factory default). Some wiring types will require an optional monitored entrapment protection device. Refer to Basic Programming Section for descriptions of wiring types, requirements and programming. Photoelectric Sensors Intended for use on vertical or high-lift sectional doors, or rolling door products. The MHS operator is recommended for rolling sheet doors. Not recommended for use on a standard lift sectional door. SECTIONAL DOOR ROLLING DOOR ga. Steel ga. Steel --- 0 ga. Steel 8 ga. Steel Aluminum Grilles Aluminum Doors --- --- Fiberglass Aluminum Doors Wood Doors ga. Steel --- ga. Steel 0 ga. Steel --- ga. Steel ga. ga. Steel --- 0 ga. Steel Insulated Insulated 0 ga. Steel --- ga. Steel --- --- --- --- ga. Steel --- --- --- 0 ga. Steel Insulated Insulated ga. Steel Insulated SQ. FT 0 0 00 0 0 NOTE: On steel insulated doors, a ga. Back panel is assumed.

OPERATOR SPECIFICATIONS WEIGHTS AND DIMENSIONS MODELS MH, MJ, AND MHS Hanging Weight: 0-0 LBS. (.-. kg).9" (. cm)." (. cm)." (. cm)." (. cm)." (8. cm)." (.8 cm) MOUNTING DIMENSIONS A - Wall Mounting B - Bracket Mounting (rolling door) A A 8.8" (.9 cm) B." (. cm) B." (. cm) B B A A.9" (8. cm)." (0.8 cm).8" (0.0 cm) 9.9" (. cm) Hand Chain Wheel present with Model MH only. " (.8 cm) MODEL MGJ ONLY Hanging Weight: 0 LBS. (. kg) 9.9" (. cm)." (.0 cm)." (.90 cm) MOUNTING DIMENSIONS.0" (.9 cm).00" (.8 cm) 9." (.0 cm).00" (.9 cm).00" (. cm)." (.0 cm)

OPERATOR SPECIFICATIONS MOTOR TYPE:..................................... Limited duty HORSEPOWER:.................................. / HP VOLTAGE:..................... Vac, Single Phase, 0 Hz OPERATOR CURRENT (Amperage): Voltage-Phase.................................. / HP -Ø, 0Hz..................................... MECHANICAL DOOR SPEED:..............Approximately 9" ( cm) / second depending on door setup OUTPUT FORCE:.......................... ft. lbs / sec. MGJ ONLY............................ 0 ft. lbs / sec. OUTPUT RPM: MJ......................................... 80 RPM MH........................................ 80 RPM MHS..................................... 8. RPM MGJ....................................... RPM LIMIT ADJUST:............ Fully adjustable up to ' door Max DUTY:............................ Cycles per Hour Max 0 Cycles per Day Max DRIVE TRAIN:.................... Maintenance Free Bearings MGJ ONLY................... Maintenance Free Bearings Wormgear-in-Oil-Bath Reducer FINISH:............. Powder coated, Corrosion Resistant Steel ELECTRICAL OPERATOR VOLTAGE:........... Vac, Single Phase, 0 Hz WIRING TYPE:................ C (Standard) B Configurable (See Basic Programming Section) CONTROL WIRING:........................... - AWG SAFETY DISCONNECT: MH.......................... Floor level chain hoist for manual chain hoist operation. MJ........................... Floor level disconnect for manual operation. MHS.... Both MH and MJ type disconnects described above. MGJ......................... Floor level disconnect for manual operation. ENTRAPMENT PROTECTION: LiftMaster Monitored Entrapment Protection (LMEP) Photoelectric Sensors (CPS-U):............... Through beam used to provide non-contact safety protection. Safety Edge (Optional):......... Electric or pneumatic sensing device attached to the bottom edge of door. (see Accessory Page ) ENVIRONMENTAL LOCATION:............................Indoor, dry location OPERATING TEMPERATURE:.................- F to + F (-0 C to + 0 C) UL Listed to 0 C: Chamberlain tested to 0 C CARTON INVENTORY Before beginning your installation check that all components were provided. Your model may look different than the model illustrated. ^ ^ OPEN CLOSE O Warning Placard -Button Station Operator Operator Drive Sprocket Door/Operator Chain Hoist Hand Chain Models MH and MHS ONLY NOT SHOWN Installation Manual Quickstart Guide User s Guide Entrapment Warning Placard Installation Hardware Bag, Complete with: Master links (), Wall bracket (), Fastener Bag () Door sprocket

PREPARATION PREPARING YOUR DOOR The manufacturer recommends feet (9. cm) of clearance in front of operator for serviceability. Before you begin: Disable locks. Remove any ropes connected to door. Before the operator is installed, be sure the door has been properly aligned and is working smoothly. Although each installation will vary due to particular building characteristics, refer to the following general procedures to install the operator. HANDING IDENTIFICATION For MH and MHS models with manual hoist hand chain systems, the handing of the operator must be determined at the time of order. The handing is indicated by last letter of the model name (R or L). The illustration shown is a right-handed operator for models MJ and MHS series only. Left-handed operator will have hoist chain on the left side. The hand chain wheel can not be switched on site. If your installation causes the hand chain to hang in the door opening, hook the chain off to the side near the top of the door jamb. Output Shaft RIGHT-HANDED OPERATOR MODEL SHOWN: MH0UR ASSEMBLY Install operator drive sprocket. RIGHT-HAND ASSEMBLY LEFT-HAND ASSEMBLY Operator Drive Sprocket Drive Shaft Drive Shaft Operator Drive Sprocket

TYPICAL INSTALLATION NOTE: The illustrations may not depict your installation. DETERMINE MOUNTING LOCATION FOR OPERATOR The operator may be mounted on the wall, shelf or bracket (not provided, see accessories or door manufacturer). The optimum distance between the door shaft and operator drive shaft is - inches. WALL MOUNT SHELF OR BRACKET MOUNTING Door Shaft Door Shaft Operator Drive Shaft Optimum Distance "-" Operator Drive Shaft Optimum Distance "-" Optional Mounting Bracket. See Accessories. INSTALL THE OPERATOR Place door sprocket on door shaft. Place operator door sprocket on operator. Door Shaft Door Sprocket Drive Shaft Operator Drive Sprocket 8

TYPICAL INSTALLATION INSTALL THE OPERATOR Wrap drive chain around door sprocket. Wrap drive chain around operator sprocket. Drive Chain Door Sprocket Electrical Box Door Sprocket Operator Drive Sprocket Drive Chain Master Link Position the operator until chain is taut (not tight). If chain is too tight, it may cause damage to operator. Operator Drive Sprocket Door Sprocket Door Sprocket Key Keep door sprocket and operator door sprocket aligned. If sprockets are not aligned, they may cause premature wear on the chain. Door Set Screw Key Secure both sprockets with key and set screw. If sprockets are not secure, they may drift and cause damage to operator. 8 Secure operator to mounting surface using appropriate method and hardware. Mounting template can be found on carton. 9

TYPICAL INSTALLATION INSTALL EMERGENCY DISCONNECT SYSTEM MODELS MH AND MHS ONLY The MHS operator includes both a floor level disconnect sash chain to disconnect the door from the door operator that allows manual push up operation and an additional sash chain to engage the manual chain hoist that also electrically disables the operator controls. Secure chain retaining bracket to wall feet above the floor. Wrap hand chain around hand chain wheel and through chain guide. Connect the ends of the hand chain. MODELS MJ AND MGJ ONLY Secure keyhole bracket to wall feet above the floor. Keyhole Bracket Hand Chain Wheel ' above floor Chain Retaining Bracket (with pad locking provisions) Hand Chain ' ' Floor 0

TYPICAL INSTALLATION POWER AND GROUND WIRING CONNECTIONS To reduce the risk of SEVERE INJURY or DEATH: ANY maintenance to the operator or in the area near the operator MUST NOT be performed until disconnecting the electrical power and locking-out the power. Upon completion of maintenance the area MUST be cleared and secured, at that time the unit may be returned to service. Disconnect power at the fuse box BEFORE proceeding. Operator MUST be properly grounded and connected in accordance with local electrical codes. The operator should be on a separate fused line of adequate capacity. ALL electrical connections MUST be made by a qualifi ed individual. DO NOT install ANY wiring or attempt to run the operator without consulting the wiring diagram. ALL power wiring should be on a dedicated circuit and well protected. The location of the power disconnect should be visible and clearly labeled. ALL power and control wiring MUST be run in separate conduit. NOTE: Power and control wiring must be run in separate conduit in accordance with national and local electrical codes. Must use AWG or heavier wire for power wiring. Use conduit knockouts for wiring as indicated on the electrical box labels. IMPORTANT NOTE: Operator must be properly grounded. Failure to properly ground the operator could result in electric shock and serious injury. DO NOT turn power on until you have fi nished making ALL power and control wiring connections. POWER WIRING CHART DISTANCE GAUGE 0 feet AWG 00 feet AWG 00 feet 8 AWG* 0 feet AWG* 00 feet AWG* 000 feet AWG* * Maximum wire gauge that can be connected to the operator s terminal is AWG. When a larger wire gauge is required, the wire must be gauged down to AWG. USE COPPER WIRE ONLY. Remove cover. Run power wires to electrical box according to national and local electrical codes. Electrical Box Sealing Nut (Not Provided) Conduit Electrical Box Cover

OPEN CLOSE O TYPICAL INSTALLATION POWER AND GROUND WIRING CONNECTIONS Attach power and ground wires to terminals. Power Ground Neutral Hot Control Line Power Vac Single Phase INSTALL -BUTTON CONTROL STATION To prevent possible SERIOUS INJURY or DEATH from electrocution: Be sure power is NOT connected BEFORE installing door control. To prevent possible SERIOUS INJURY or DEATH from a closing door: Install door control within sight of door, out of reach of children at a minimum height of feet (. m) and away from ALL moving parts of door. Install the control station far enough from the door to prevent the user from coming in contact with the door while operating the controls. Install the entrapment warning placard on wall next to the control station in a prominent location that is visible from the door. NEVER permit children to operate or play with door control push buttons or remote controls. Activate door ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to door travel. ALWAYS keep door in sight until completely closed. NEVER permit anyone to cross path of closing door. Remove the control station cover. Select appropriate knockout and run the wires to the operator. Fasten the control station to the wall at least feet above the ground. The installation surface must be smooth and fl at. Conduit Screws ^ OPEN ^ CLOSE O ^ ^ Wall ' (. m) -Button Control Station ^ OPEN ^ CLOSE O Knockout Ground

AUX ANT AUX ANT ^^^^ LMEP LMEP D COM INTRLK CLOSE OPEN TYPICAL INSTALLATION INSTALL -BUTTON CONTROL STATION Connect wires to the control station and replace the control station cover. Power Fasten the entrapment warning placard next to the control station. UL Entrapment Placard Logic Board Control Remove factory jumper if external interlock is used. R D LMEP LMEP COM INTRLK Stop Close Open Warning Placard -Button Control Station ^ ^OPEN CLOSE O Common SETUP RADIO ANTENNA OPTION A Locate the wire antenna on the outside of the electrical box. Cut the wire tie closest to the edge of the electrical box. Press the plastic standoff into the hole in the side of the electrical box. Antenna Wire Ties Standoff Cut this Wire Tie Cut Wire Tie Antenna

TYPICAL INSTALLATION SETUP RADIO ANTENNA OPTION B Locate the wire antenna on the outside of the electrical box. Cut wire ties and discard standoff. Attach the antenna to the electrical box using the wire tie holes. Bend antenna across the front of the electrical box, ensuring that the antenna is inches away from the front of the electrical box. Wire Ties Antenna Cut these Wire Ties WARNING Cut Wire Ties NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifications of this receiver and/or transmitter are prohibited, except for changing the code setting or replacing the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS. Tested to Comply with FCC Standards FOR HOME OR OFFICE USE. Operation is subject to the following two conditions: () this device may not cause harmful interference, and () this device must accept any interference received, including interference that may cause undesired operation. WARNING IMPORTANT SAFETY INSTRUCTIONS WARNING. READ AND FOLLOW ALL WARNINGS AND INSTRUCTIONS.. ALWAYS keep remote controls out of reach of children. NEVER permit children to operate or play with door control push buttons or remote controls.. ONLY activate door when it can be seen clearly, it is properly adjusted and there are no obstructions to door travel.. ALWAYS keep door in sight until completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR.. NO ONE SHODULD GO UNDER A PED, PARTIALLY OPENED DOOR.. If possible, use manual release handle to disengage door ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly.. NEVER use manual release handle unless doorway is clear of persons and obstructions. 8. After ANY adjustments are made, the entrapment protection device MUST be tested. 9. Entrapment Protection device MUST be tested every month. 0. ALWAYS KEEP DOOR PROPERLY BALANCED. An improperly balanced door may NOT reverse when required and could result in SEVERE INJURY or DEATH.. ALL repairs to cables, spring assemblies and other hardware, ALL of which are under EXTREME tension, MUST be made by a trained door systems technician.. ALWAYS disconnect electric power to door operator BEFORE making ANY repairs or removing covers.. SAVE THESE INSTRUCTIONS.

ADJUSTMENT ADJUST THE LIMITS To avoid SERIOUS personal INJURY or DEATH from electrocution: Disconnect electric power BEFORE performing ANY adjustments or maintenance. Adjust OPEN limit. Retaining Plate OPEN Limit Nut OPEN Limit Switch CLOSE Limit Nut CLOSE Limit Switch Decrease Door Travel Increase Door Travel Increase Door Travel Decrease Door Travel SAFETY Limit Switch NOTE: When retaining plate is released, verify that the retaining plate is fully seated with the notches of the limit nut. ADJUST THE CLUTCH FOR MODELS MJ, MH, AND MHS ONLY Apply power to operator. Turn clutch nut to release tension. Re-tighten nut until there is just enough tension to permit smooth operation. Replace cotter pin. Bend ends of cotter pin to secure clutch nut. A B To Loosen Clutch Nut To Tighten

ENTRAPMENT PROTECTION LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP) IMPORTANT INFORMATION ABOUT THE LIFTMASTER MONITORED ENTRAPMENT PROTECTION DEVICES A LiftMaster Monitored Entrapment Protection (LMEP) device is required for most wiring types. If a LiftMaster Monitored Entrapment Protection device is not installed, constant pressure to close will be required from the control station. When properly connected and aligned, the photoelectric sensors will detect an obstruction in the path of its invisible light beam. If an obstruction breaks the light beam while the door is closing, the door will stop and typically reverse to the full open position. The photoelectric sensors must be installed facing each other across the door, no more than " ( cm) above the floor. Each photoelectric sensor has an that will glow steady when the sensor is properly connected and aligned. The s on both photoelectric sensors will flicker rapidly when obstructed or misaligned. To prevent possible SERIOUS INJURY or DEATH from a closing door: Be sure power is NOT connected to the door operator BEFORE installing the photoelectric sensor. The door MUST be in the fully opened or closed position BEFORE installing the LiftMaster Monitored Entrapment Protection device. To prevent SERIOUS INJURY, DEATH, ENTRAPMENT, or PROPERTY DAMAGE: Correctly connect and align the photoelectric sensor. Install the photoelectric sensor beam NO HIGHER than " ( cm) above the fl oor. This is a required safety device for B, TS, T, and FSTS wiring types and MUST NOT be disabled. For D, C, and E wiring the installation of an entrapment device is recommended. LiftMaster Monitored Entrapment Protection devices are for use with LiftMaster Commercial Door Operators ONLY. Use with ANY other product voids the warranty. If an edge sensor is being used on a horizontal slide door, then place one or more edge sensors on both the leading and trailing edge. If an edge sensor is being used on a vertically moving door, then place one or more edge sensors on the bottom edge of the door. Left Side of Garage Right Side of Garage Photoelectric Safety Reversing Sensor " ( cm) Sensor max. above fl oor Invisible Light Beam Invisible Protection Light Area Beam Protection Area Photoelectric Safety Reversing Sensor " ( cm) max. above fl oor

ENTRAPMENT PROTECTION INSTALL THE PHOTOELECTRIC SENSORS The following instructions show recommended assembly of the bracket(s) and C wrap based on the wall installation of the photoelectric sensors on each side of the door or on the door tracks themselves. There are also alternate mounting methods which may fi t your installation requirements better. Make sure the wraps and brackets are aligned so the photoelectric sensors will face each other across the door. Fasten the C wraps to the mounting brackets having square holes, using hardware shown. Mounting Bracket with Square Holes C Wrap #0- Lock Nuts WALL INSTALLATION Connect each assembly to a slotted bracket, using the hardware shown. Note alignment of brackets for left and right sides of the door. Finger tighten the lock nuts. Use bracket mounting holes as a template to locate and drill () /" diameter pilot holes on both sides of the garage door, - inches (0- cm) above the fl oor. Do not exceed inches ( cm). Attach bracket assemblies with /"x-/" lag screws. Adjust right and left side bracket assemblies to the same distance out from mounting surface. Make sure all door hardware obstructions are cleared. Tighten the nuts securely. Inside Wall /"x-/" Lag Screws /"-0x/" Carriage Bolts (with square shoulders) #0-x/8" Screws DOOR TRACK INSTALLATION Discard slotted bracket. Drill /8" holes in each track and fasten securely with hardware. Door Track Drill /8" Holes /"-0x/" Carriage Bolts Inside Wall Mounting Bracket with Square Holes /" Lock Nuts C Wrap /"-0 Lock Nuts Mounting Bracket with Slot Mounting Bracket with Square Holes C Wrap ALTERNATE WALL INSTALLATION Inside Wall Mounting Bracket with Slot Mounting Bracket with Square Holes C Wrap ALTERNATE FLOOR INSTALLATION Inside Wall Sensor with Wire Indicator Light Mounting Bracket with Square Holes Mounting Bracket with Slot - Floor - Sensor with Wire Indicator Light C Wrap - Floor - Attach with Concrete Anchors (Not Provided)

ENTRAPMENT PROTECTION MOUNT THE PHOTOELECTRIC SENSORS Center each sensor in the bracket with the lenses pointing toward each other across the door. Wing Nut Attach the sensors to the brackets with the provided hardware. Finger tighten the receiving sensor wing nut. Securely tighten the sending sensor wing nut. C Wrap Wire Indicator Light Run the wires from both sensors to the operator. Use insulated staples to secure wire to the wall and ceiling. Sensor /"-0x-/" Hex Bolt Connect the sensor wires to the operator. Secure wire with insulated staples Bell Wire Connect wire to Operator Photoelectric Sensor " ( cm) max. above floor Invisible Light Beam Protection Area Photoelectric Sensor " ( cm) max. above floor ENTRAPMENT PROTECTION WIRING OPTIONS PRIMARY INSTALLATION: CPS-U PHOTOELECTRIC SENSORS X ANT ANT (White) (White/Black) NOTE: When installing model CPS-UN, connect the brown wire to terminal and the blue wire to terminal. LMEP LMEP COM INTRLK D ^^^^ 8

ENTRAPMENT PROTECTION ENTRAPMENT PROTECTION WIRING OPTIONS ALTERNATE INSTALLATIONS: CPS-U PHOTOELECTRIC SENSOR WITH -WIRE SENSING EDGE -wire electric or pneumatic sensing edge (White) (White/Black) CPS-U PHOTOELECTRIC SENSOR WITH -WIRE SENSING EDGE -wire electric sensing edge (White/Black) LMEP LMEP COM INTRLK D ^^^^ (White) LMEP LMEP COM INTRLK D ^^^^ -WIRE ELECTRIC OR PNEUMATIC SENSING EDGE (B NOT AVAILABLE) -wire electric or pneumatic sensing edge (White/Black) (White) LMEP LMEP COM INTRLK D ^^^^ LOGIC BOARD LAYOUT ITEM DESCRIPTION FUNCTION Open Button Open Door Close Button Close Door Stop Button Stop Door Learn Button Programs the remote controls and performs additional programming Timer-to-Close Button Programs the Timer-to-Close Purple Wire Antenna Primary Antenna Auxiliary Antenna Connection For use with external antenna kit -EXT-ANT. Not Provided 8 Used during programming and diagnosing error codes 9 Field Wiring Terminal Field wiring connections 0 Factory Wiring Connector Factory wiring harness connection AUX ANT ^^^^ D LMEP LMEP COM INTRLK 9 8 0 9

BASIC PROGRAMMING DETERMINE THE WIRING TYPE The functionality of this operator is based on the wiring type. The operator is shipped from the factory in standard C wiring type (factory default). LIFTMASTER MONITORED ENTRAPMENT PROTECTION (LMEP) DEVICE IS RECOMMENDED. A LiftMaster Entrapment Protection (LMEP) device is required for any momentary contact to close mode of operation including B, and remote controls. NOTES: The on the logic board will blink once when in C and twice when in B. The operator will automatically convert to B wiring when Monitored Entrapment Protection Device is installed. If the Monitored Entrapment Protection Device is blocked or removed, the operator will go into a Restricted Close mode**. ** Restricted close mode requires a constant pressure close command. The operator will begin closing after a second delay and will continue to close to the close limit switch. The operator will stop if the pressure to close is released before reaching the close limit. RECOMMENDED INSTALLATION: B WIRING TYPE WITH MONITORED ENTRAPMENT PROTECTION DEVICE Momentary contact to open, close and stop. Open override that reverses when closing by any opening device. Wiring for entrapment protection device to reverse. NOTE: The operator will automatically convert to B wiring when Monitored Entrapment Protection Device is installed. (See accessories page for Monitored Entrapment Protection Devices.) Timer-to-Close () feature available. No Programming Required MONITORED ENTRAPMENT PROTECTION DEVICE Photoelectric Sensor 0

C0 TP C9 L ^^^^ C8 J R D D9 0A00 C LMEP LMEP COM INTRLK J C R U K LT C9 R P C D U D D D BASIC PROGRAMMING DETERMINE THE WIRING TYPE ALTERNATE INSTALLATION: C WIRING TYPE WITH MONITORED ENTRAPMENT PROTECTION DEVICE Momentary contact to open and stop with constant pressure to close. Open override that reverses when closing by any opening device. Wiring for entrapment protection device to reverse. NOTE: The operator will automatically convert to B wiring when Monitored Entrapment Protection Device is installed. (See accessories page for Monitored Entrapment Protection Devices.) Timer-to-Close () feature not available. MONITORED ENTRAPMENT PROTECTION DEVICE ALTERNATE INSTALLATION: C WIRING TYPE WITHOUT MONITORED ENTRAPMENT PROTECTION DEVICE (FACTORY DEFAULT) Momentary contact to open and stop with constant pressure to close. Open override that reverses when closing by any opening device. Wiring for entrapment protection device to reverse. NOTE: The operator will automatically convert to B wiring when Monitored Entrapment Protection Device is installed. (See accessories page for Monitored Entrapment Protection Devices.) Timer-to-Close () feature not available. NON-MONITORED ENTRAPMENT PROTECTION DEVICE Photoelectric Sensor To Program: Press and hold the and CLOSE buttons until the goes out (approximately seconds). Electrical Box Logic Board D Sensing Edge Reset to FACTORY DEFAULT (C) when the Monitored Entrapment Protection Device has been learned and then removed: Remove any monitored entrapment protection devices. Turn the main power OFF and then ON to restore the operator to the FACTORY DEFAULT setting. To Reset to B with Monitored Entrapment Protection Device: Press and hold the and buttons until the goes out (approximately seconds). REMOTE CONTROLS RADIO OPERATION MODE OPEN CLOSE REVERSE WHILE CLOSING RESET B X X X X B with X X (-button remote) X X X when open C X X X

BASIC PROGRAMMING REMOTE CONTROLS To prevent possible SEVERE INJURY or DEATH: Install a LiftMaster Monitored Entrapment Protection (LMEP) device. NEVER permit children to operate or play with door control push buttons or remote controls. Activate door ONLY when it can be seen clearly, is properly adjusted and there are no obstructions to door travel. ALWAYS keep door in sight until completely closed. NEVER permit anyone to cross the path of closing door. Built in MHz radio receiver permits as many as 0 Security+ remote controls or dip switch remote controls in any combination. SINGLE BUTTON REMOTE CONTROL D LMEP LMEP COM INTRLK ^^^^ D ANT AUX Press and hold the button (over seconds) until the goes out. All programmed remote controls will be erased. R D D LMEP LMEP COM INTRLK R ^^^^ LMEP LMEP COM INTRLK ANT AUX LMEP LMEP COM INTRLK Press and release the button ( will light). TO ERASE ALL REMOTE CONTROLS Press and hold the button on the remote control until the flashes rapidly, then release to complete programming ( will go out). Repeat steps and for additional remote controls. -BUTTON REMOTE CONTROL TO OPERATE AS A WIRELESS -BUTTON CONTROL STATION NOTE: The feature will use of the 0 memory channels in the operator. R D D D LMEP LMEP COM INTRLK R LMEP LMEP COM INTRLK ^^^^ LMEP LMEP COM INTRLK ANT AUX Press and hold the button ( will light). Press and hold the desired button of the remote control until flashes rapidly, then release. Press the desired button on the logic board (OPEN, CLOSE or ). Release both buttons. Repeat steps through to program additional buttons. TIMER-TO-CLOSE () Timer-to-Close feature enables the operator to close from the open limit after a preset time, adjustable from to 0 seconds. Requires LiftMaster Monitored Entrapment Protection (LMEP) device. NOTE: The will attempt to close the door consecutive times. If the unit fails to close (sensors obstructed, OPEN command given, etc.) the is canceled for that cycle and a manual CLOSE command will be required. The will automatically reactivate on the next cycle. TO PROGRAM Begin with door in fully closed position. R Press and release the button to exit programming mode. The will flash once per seconds of timer setting. D D LMEP LMEP COM INTRLK R D LMEP LMEP COM INTRLK R LMEP LMEP COM INTRLK R D D Every press and release of the button will add seconds to the Timer-to-Close. Example: 0 second = presses of the button. LMEP LMEP COM INTRLK ^^^^ LMEP LMEP COM INTRLK ANT AUX Press and release the button ( will light). Press and release the button. The will become active after completion of the next open cycle. NOTE: The does not indicate that timer is running. TO VERIFY TIMER-TO-CLOSE () SETTING R D D Press and release the button. LMEP LMEP COM INTRLK R D D LMEP LMEP COM INTRLK R LMEP LMEP COM INTRLK ^^^^ LMEP LMEP COM INTRLK ANT AUX Press and hold the button ( will light). Press and release the button a second time. The will flash once per seconds of timer setting.

^^^^ D LMEP LMEP COM INTRLK BASIC PROGRAMMING TIMER-TO-CLOSE () CLEAR THE TIMER-TO-CLOSE () Press and hold LMEP LMEP COM INTRLK CLOSE OPEN D R Press and release the button ( will light). LMEP LMEP COM INTRLK CLOSE OPEN D R the button for seconds. LMEP LMEP COM INTRLK D R Release the button ( will go out). The TCC will no longer be active. TIMER DEFEAT The can be temporarily disabled by pressing a button. will become enabled after the next open command. TESTING To avoid SERIOUS personal INJURY or DEATH: Disconnect electric power BEFORE performing ANY adjustments or maintenance. ALL maintenance MUST be performed by a trained door systems technician. Turn on power, will fl ash times on power up. Test all controls and entrapment protection devices to make sure they are working properly. It may be necessary to refer back to the Adjustment section for adjustment of the limits. IMPORTANT NOTES: Do not leave power to the operator on unless all entrapment protection devices have been tested and are working properly. Be sure you have read and understand all safety instructions included in this manual. Be sure the owner or person(s) responsible for operation of the door have read and understand the safety instructions, know how to electrically operate the door in a safe manner and how to manually disconnect the door from the operator. TEST -BUTTON CONTROL STATION Press OPEN button. (The door should move in the open direction.) Press button. (The door should stop.) Press CLOSE button. (The door should move in the close direction.) Release CLOSE button. Door should stop if in C mode. (The door should continue closing if in B mode.) Press button. (The door should stop.) TEST LIMIT ADJUSTMENT Press OPEN button. (The door should open.) Allow the door to fully open. Press CLOSE button. (The door should close.) Allow the door to fully close. If the limits are not set properly, remove power and adjust limits (refer to Adjustment section). TEST THE ENTRAPMENT PROTECTION DEVICES Open the door. Place an obstruction in the path of the photoelectric sensors or sensing edge. Press the CLOSE button. The door should not close if photoelectric sensors are installed. The door should close to obstruction and reverse if sensing edge is installed. Remove the obstruction. Press CLOSE button. Door should close. If door did not reverse from obstruction, check entrapment protection devices. TEST REMOTE CONTROL Requires B wiring type and compatible LiftMaster remote control. In C wiring the remote control will open the door only. Press remote control button. Door should open. Allow the door to fully open. Press remote control button. Door should close. Allow door to fully close.

EMERGENCY DISCONNECT To prevent possible SERIOUS INJURY from a moving chain: DISCONNECT electric power to the operator BEFORE manually operating your door. If possible, use emergency disconnect ONLY when door is CLOSED. Weak or broken springs or unbalanced door could result in an open door falling rapidly and/or unexpectedly. NEVER use emergency disconnect unless doorway is clear of persons and obstructions. If door locks have been installed, disengage door locks prior to releasing the emergency release handle. This operator has provisions for manually operating the door in case of emergency or power failure. Refer to the appropriate instructions below for your model operator. MODEL MH These operators are equipped with a manual hoist. An electrical interlock will disable the electrical controls when the hoist is used. MODELS MJ AND MGJ This operator has a fl oor level disconnect chain to disconnect the door from the door operator. Pull the disconnect chain (sash chain) to engage the hoist mechanism. The disconnect chain may be locked in position by slipping the end through the keyhole of the chain keeper mounted on the wall. Operate the door in the desired direction by pulling on one side or the other of the continuous loop hoist chain. The disconnect chain must be released from the chain keeper before the door will operate again electrically. To disengage, pull the chain and secure in the disengaged position by slipping the end through the keyhole bracket mounted on the wall. Or if emergency egress device is used, pull handle to disengage operator from door. The door may now be pushed up or pulled down manually. Release the disconnect chain or reset the emergency egress device to operate the door again electrically. MODEL MHS The MHS operator includes both a fl oor level disconnect sash chain to disconnect the door from the door operator that allows manual push up operation and an additional sash chain to engage the manual chain hoist that also electrically disables the operator controls. Refer to Model MH instructions for hoist operation. Refer to Model MJ instructions for manual operation. When the manual chain hoist sash chain is engaged, electrical operation will not function. Keyhole Bracket EMERGENCY DISCONNECT FOR MODELS MJ ELECTRICAL INTERLOCK WITH HOIST FOR MODELS MH AND MHS Chain Keeper (with pad locking provisions)

TROUBLESHOOTING Technical Support -800-8-80 CONDITION POSSIBLE CAUSE FIX OPERATOR WILL NOT RESPOND TO ANY COMMANDS A) No power Verify primary line voltage (0 Vac, 0 Hz) is present at terminals L & L. The will fl ash when power is present. B) Stop circuit not complete Verify Stop Button input (terminals & ) is properly wired and stop button is not stuck. C) Stuck button on -button control station Verify that all buttons are actuating freely and releasing properly. D) Interlock input activated Verify jumper is located at terminals & if interlock is not present. Verify interlock is properly wired and not activated. E) Motor overload tripped Overload is internal within motor. Allow to cool and retry. F) Accessory failure Attempt to close by holding the CLOSE button for more than seconds. If door closes, check accessory for proper wiring, polarity, connections or damage. Verify photoelectric sensors are aligned or sensing edge is not activated. G) Possible component failure Call Technical Support for assistance. OPERATOR MAKES NOISE BUT DOOR A) Clutch slipping Adjust clutch, see ADJUSTMENT section. DOES NOT MOVE B) Brake not releasing (if present) Verify brake assembly operation and wiring. C) Door operation problem Disconnect trolley and check door for proper operation. OPERATOR MOVES OPEN and CLOSE button IN THE WRONG wiring connection reversed DIRECTION Check -button control wiring. DOOR DRIFTS AFTER OPERATOR S A) Door not balanced properly Disconnect trolley assembly and check door for proper operation. B) Clutch slipping Adjust clutch, see ADJUSTMENT section. DOOR OPENS/ CLOSES TOO FAR DOOR REVERSES UNEXPECTEDLY NOT FUNCTIONING RADIO FUNCTIONALITY NO RESPONSE C) Brake not functioning properly Limits not adjusted properly Check brake mechanism to ensure brake lever is free and brake pads are engaging the brake disc. Adjust limits. See ADJUSTMENT section. Intermittent Entrapment Protection Device activation Check all connections. A) Monitored Entrapment Check all connections. Verify photoelectric sensors are not blocked and the Protection Devices sensing edge is not activated. B) temporarily disabled Close and Open the door. will be re-enabled. C) not programmed properly Reprogram. See PROGRAMMING section. NOTE: Built in radio receiver compatible with all LiftMaster MHz remote control devices. A) Remote control is not programmed See PROGRAMMING REMOTE CONTROLS section. B) Remote control not compatible Obtain qualifi ed LiftMaster remote control device. C) Low battery Replace battery. REMOTE CANNOT BE ED A) Low battery Replace battery. B) Remote control not compatible Obtain qualifi ed LiftMaster remote control device. POOR RADIO RANGE A) Low battery in remote Replace battery. B) Antenna not confi gured See SETUP RADIO ANTENNA. C) Ambient radio interference or building structural issue Use EXTERNAL ANTENNA kit (see ACCESSORIES page).

TROUBLESHOOTING The status of the operator can be determined by counting the number of flashes of the on the logic board. # OF FLASHES STATUS FIX System OK. Operating in C mode None System OK. Operating in B mode None DIAGNOSTIC TABLE Stuck CLOSE button Check for stuck close button or shorted close wire Monitored Entrapment Protection Device failure Check for: ) Misaligned or blocked Photoelectric Sensors. ) Issue with Monitored Sensing Edge and/or wiring. Incorrect motor direction Reverse the yellow and red motor wires on the capacitor. Maximum run timer has timed out (Maximum run time = 90 seconds) Check clutch adjustment. Door height or speed may exceed the range the operator can travel. Call Technical Support for assistance. Logic Board Failure Replace Logic Board. NOTE: It is normal for the logic board to fl ash times when power is applied or cycled to the operator. (Not a logic board failure.) RESTRICTED CLOSE This method will allow you to close the door when LMEP device(s) are no longer working. Press and hold the CLOSE button until the door reaches the closed limit. If the CLOSE button is released before the door reaches the closed limit the operator will stop and the procedure will need to be repeated to fully close the door. DIAGRAM Green ** If interlock is not used, wires are capped together. Interlock Brake (Optional) Blue* White* * If brake is not supplied, wires are capped separately Black Black L L Capacitor Black Yellow OPEN Motor CLOSE Safety Limit Switch ANT J Red Yellow Red Brown** Orange Purple Yellow Grey LMEP LMEP COM INTRLK Remove Jumper to install external door interlock. Open Limit Switch Grey Close Limit Switch

ACCESSORIES ENTRAPMENT PROTECTION DEVICES MONITORED CPS-U Dual-Sided Infrared Photo Eyes NEMA general purpose enclosure. Dual-sided infrared sensors. For indoor use. Maximum range of 0 feet (9. m). CPS-UN Monitored Thru-Beam Photo Eyes Heavy-duty housing for industrial applications. NEMA enclosure protects against direct spray. Dual-sided infrared sensors. For indoor/outdoor use. Maximum range of feet (. m). CPS-RPEN Monitored Retro-Reflective Photo Eyes Polarized reflector for use in applications with highly reflective surfaces. NEMA X enclosure protects against direct water spray and corrosion. Retro-reflective sensor. For indoor/outdoor use. Maximum range of 0 feet ( m). CPS-OPEN Monitored Dual-Sided Photo Eyes Flexible housings maintain alignment in areas with a high propensity for sensor contact. NEMA X enclosure protects against direct water spray and corrosion. Dual-sided infrared sensors. For indoor/outdoor use. Maximum range of feet (. m). Optical Edge System (OES) OES-SD Optical Edge System feet (.9 m) Sectional -Wire Door Edge Kit with infrared optical sensors, rubber door edge and all mounting hardware (channel sold separately). OES-SD OES-RD Optical Edge System feet (. m) Sectional -Wire Door Edge Kit with infrared optical sensors, rubber door edge and all mounting hardware (channel sold separately). Optical Edge System feet (.9 m) Rolling -Wire Door Edge Kit with infrared optical sensors, rubber door edge and all mounting hardware (door channel not required). Rubber door edge is durable, flexible and easy to install. Premium rubber can be cut to length for exact fit. NEMA rating protects against moisture and standing water. Infrared optical sensors eliminate the need for electrical contacts. Maximum range of feet (0 m). Sectional and rolling door edges are also available in 0 foot ( m) bulk rolls, along with individual components for additional savings on large installation jobs. CPS-EI Edge Interface -Wire Monitored For use with approved -wire edges. CHAIN TENSIONERS For Jackshaft Type Operators -0 Chain Tensioner: For " shafts - Chain Tensioner: For -/" shafts REMOTE CONTROLS MHZ LiftMaster offers a variety of SECURITY+ Remote Controls for your application needs. Single to -Button, visor or key chain. Contact your authorized dealer. LM LM LM OPEN^^ OPEN CLOSE O 0 0 Sectional Door Interlock Switch: NEMA switch is engaged by sectional door lock mechanism and disables operator control circuit when door is locked, thereby preventing electrical operation of door when locked. Mounts next to door lock, requires -wire connection to operator. May be used with all LiftMaster industrial operators on sectional doors. FIELD MODIFICATION KITS MLSBC Single Button Control: Provides additional input for Single Button Control functionality. Input functions as Close input when the operator is stopped at the Open limit. Input functions as Open input at all other times. Also used with external radio controls. MLMOTION Door-In-Motion: Provides dry contact and a terminal block with contacts switched to power an auxiliary device while the door is in motion. ANTENNA EXT-ANT -Button SECURITY+ Remote Control Includes visor clip. -Button SECURITY+ Remote Control Includes visor clip. -Button Tri-Colored Dip Switch Remote Control Open/Close/Stop functionality. Includes visor clip. CONTROL STATIONS 0-0 -Button Control Station Steel enclosure. 0-0 0-09 -Button Control Station Steel enclosure. Key Control Station Indoor flush mount, NEMA. DOOR INTERLOCK SWITCH 0 0 Rolling Door Interlock Switch: NEMA switch is engaged by rolling door lock mechanism and disables operator control circuit when door is locked, thereby preventing electrical operation of door when locked. Mounts at bottom of door guide, requires -wire connection to operator. May be used with all LiftMaster industrial operators on rolling doors. Antenna: External kit for medium duty. 8LM (' [. m]) 8LMT (' [. m]) Antenna Extension Kit: The antenna extension kit can be used with EXT-ANT for maximum radio receiver range. MOUNTING BRACKETS 0-0 Mounting Brackets: Angle mounting bracket, Painted steel, for MJ, MH, and MHS. 0-909 Medium Duty Angle Mounting Bracket: Heavy-gauge steel bracket. May be welded. For use with MJ, MGJ, and MH operators.

CONTROL CONNECTION DIAGRAM IMPORTANT NOTES:. The -Button Control Station provided must be connected for operation.. If a button is not used, a jumper must be placed between terminals and.. If INTERLOCK is not used a jumper must be placed between terminals and.. When adding accessories, install them one at a time and test each one after it is added to ensure proper installation and operation with the Commercial Door Operator. BUTTON STATION OR POSITION KEYSWITCH WITH SPRING RETURN TO CENTER AND BUTTON STANDARD OR MORE KEY LOCKOUT Open Close Open Close Open Close Open Close Stop Stop Stop Stop Keyswitch BUTTON STATION OR POSITION KEYSWITCH WITH SPRING RETURN TO CENTER STANDARD OR MORE Open C MODE ONLY Open Open C MODE ONLY Close See note. Close Close See note. DEVICE TO REVERSE Note: For photoelectric sensors connection options see ENTRAPMENT PROTECTION section. EXTERNAL INTERLOCK Remove Factory Installed Jumper When Interlock is Used Sensing Device ONE All Wiring Types OR MORE 0, LiftMaster 0-H All Rights Reserved