Microcontroller Unit (MCU) LCD Hour Meters/Counters. LM Series. Datasheet

Similar documents
Load Accessories. Test & Measurement Sensors DESCRIPTION TONGUE SHACKLE FEATURES PULL PLATE FEATURES YOKE SHACKLE FEATURES LOAD BUTTON FEATURES

EQUIVALENT BASIC CIRCUIT

MICRO SWITCH Weather-Sealed, Explosion-Proof Switches. CX Series. Datasheet

MICRO SWITCH Solenoid Safety Interlock Switches GKL/R Series Issue 2. Datasheet

Installation and Service Instructions for EX Series Explosion-proof Switches

MICRO SWITCH Compact Limit Switches NGC Series Issue 7. Datasheet FEATURES POTENTIAL INDUSTRIAL APPLICATIONS DESCRIPTION DIFFERENTIATION

Speed Sensors Line Guide

Installation Instructions for the ISSUE 2 Explosion-proof Limit Switches LSX Series PK 81181

Honeywell Pressure Switches. Datasheet. High Pressure: HP Series, HE Series Factory set 150 psi to 4500 psi [10,34 bar to 310,26 bar]

MICRO SWITCH Compact Limit Switches NGC Series Issue 8. Datasheet FEATURES POTENTIAL INDUSTRIAL APPLICATIONS DESCRIPTION DIFFERENTIATION


VL Series. General Purpose Compact Limit Switches. Sensing and Control

onlinecomponents.com VL Series General Purpose Compact Limit Switches Sensing and Control

The Hobbs Family of Electro-Mechanical Products OFF HIGHWAY LIGHTING Thanks for considering Hobbs! MANUFACTURING HOUR METERS

Applications. Features

10260S Series Actuators Auto-Manual Switch Replacement Instruction

Model 10 Electromechanical Totalizer

MODEL 906. Battery Fuel Gauge. Read Instructions Carefully!

10260 Retrofit to 10260A Non-Contact Sensor Instructions Kits through -512

A165E CSM_A165E_DS_E_11_2

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

Digital display Pressure range ON/OFF output Linear output Model

MICRO SWITCH Compact Limit Switches NGC Series Issue 9. Datasheet FEATURES POTENTIAL INDUSTRIAL APPLICATIONS DESCRIPTION DIFFERENTIATION

Totally Sealed Hour Meter

7777D In-Line Mounting for Durafet II ph Electrodes Installation and Maintenance

MYSTR ELEMENTS. % Eo/Ein % TRAVEL % TRAVEL. Examples of monotonic functions. Examples of non-monotonic functions TECHNICAL SPECIFICATIONS DIMENSIONS

11280A HercuLine Series Actuator. Specification. Non-Contact Position Sensing and Variable Speed Motor Control. Overview. Features. Actuator Operation

D4BS CSM_D4BS_DS_E_8_4

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Technical Product Sheet

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

Model Number Structure

MODEL 908. Read Instructions Carefully! Fuel Gauge CURTIS INSTRUMENTS, INC.

DIN Track Terminal Blocks with Screw Terminals XW5T

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

Electronic lube meter

DWS404 DWS524 DWS654 DWS684 DWS694. DWS SERIES INSTALLATION/OWNER'S MANUAL Car Audio Speakers

Installation Instructions Winch Quick Connect Kit Part # (8 ) Part # (24 )

INSTALLATION INSTRUCTIONS

G3PE-Single-phase. Solid State Relays for Heaters

- Data Brochure D 156. Difference Setpoint Control 156. Item 06/10

SEE PAGE 4 FOR IMPORTANT INFORMATION CONCERNING LIMITED WARRANTY, AND LIMITATION OF LIABILITY. Operating Instructions. Please read before use

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

Fuel Meter. Instructions - Parts List. Contents B. Model , measures in gallons Model , measures in liters. For metering fuels.

HercuLine 2000 Series Gear Kit Replacement Instructions

D4GS-N CSM_D4GS-N_DS_E_7_2

FR1118- P10. User s Manual

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7

Thatching Reel Reelmaster 450 D, 4500 D, 335 D & 3500 D

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Rotating Vane Anemometer

Grundfos MAGNA, Relay Module

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

will result in death or serious injury. could result in death or serious injury. Indicates a hazardous situation which, if not avoided,

Flow Control Valve Instruction Manual

OWNERS MANUAL HF4550 PREACHER CURL. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

OWNERS MANUAL HF PAIR VERTICAL DUMBBELL RACK. Customer Service (800) (858) Fax (858) RECORD SERIAL NUMBER HERE

PK Installation Instructions for the 2CPS Series Cable Pull Switch Without Broken Cable Detection ISSUE 3. Sensing and Control

Pressurized oil drain for collection of used lubricants and anti-freeze.

INSTALLATION AND MAINTENANCE MANUAL FORM #PM-126 REV A 12/09

Power Distribution Units

MODEL NO & UP SAFETY INSTRUCTIONS. Keep this Operator s Manual in the plastic tube behind the operator seat.

Cable Ties. Data Sheet

OWNERS MANUAL HF

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

AXS609 AXS612 AXS514 AXS SERIES. INSTALLATION/OWNER'S MANUAL Car Audio

TMD90A Dual Input Digital Thermometer

Analog Durometer Model AD-100

NT1-200, NT1-200/296 Battery Backup. NT1-200 Add-on Battery. Installation Instructions. Specifications. NT1-200, NT1-200/296 Battery Backup


IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

CADDY CAT LINKS. Unleash the versatility

Indoor Air Quality Meter

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Cleaning System. Instructions/Parts A

User Manual SH Slag Removal Tool for use on laser cutting machines with minimum 1.25 between slats

HIGH VOLTAGE DIGITAL AMMETER

ASM Maxi Poles. Instruction-Parts B Series. For the application of architectural paints and coatings.

NoMAX 900 SERIES. Instruction SWITCHED CAPACITOR CONTROLS

DIN Track Terminal Blocks with Screw Terminals

DIN Track Terminal Blocks with Screw Terminals XW5T

Traffic Logix SafePace 100 Radar Speed Sign Product Specifications Version 2.7

6 OFF ROAD LIGHT BAR

Hour Meter Series HM36

CORPORA 110N DATASHEET I SEE PAGE 4 FOR IMPORTANT INFORMATION CONCERNING LIMITED WARRANTY, AND LIMITATION OF LIABILITY. I

MIL-24/2600Q MIL-24/3200DQ

Microscope light manual

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

All products subject to this warranty must be returned for examination, repair or replacement to:

Installation Instructions PART NUMBERS: 76128, 84128, CQT76128


Digital Thermometers Instruction Manual MODELS 868 and 869

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

OWNERS MANUAL HF4263

A22LK CSM_A22LK_DS_E_6_2

Megohmmeter Test Probe

Rotating Vane Anemometer

Transcription:

Microcontroller Unit (MCU) LCD Hour Meters/Counters LM Series Datasheet

LM Series Microcontroller Unit (MCU) LCD Hour Meters/Counters Honeywell s MCU (microcontroller unit) LCD (liquid crystal display) Hour Meters and Counters, LM Series, are sealed digital instruments designed to monitor and record elapsed running time, normally displayed in hours and tenths of hours. These devices are used to log running time of equipment or counts of equipment use for potential use in transportation applications to assure proper maintenance of expensive machines or systems, as well as warranty claims and rental-use tracking. This maintenance typically involves replacing, changing, or checking parts, belts, filters, oil, and lubrication of heavy duty equipment, or running condition of engines, motors, and blowers, to name a few. These devices can feature up to a 40-year memory data retention (without power) to provide customers with a long data retention capability within their desired application. The large 7 mm display eases readability and offers backlight options and a running indicator. Sealing to IP67 (front)/ip66 (rear) designed to provide enhanced durability. The hour meter also features a long reset time to offer customers the protection against malfunction of reset. The LM Series offers customization options including the customer s logo, Honeywell logo, or a black face, as well as numerous customizable bezel options. What makes our hour meters/counters better? Backlighting and large display ease readability IP67 (front) and IP66 (rear) rating provides enhanced durability Longer reset time can minimize the possibility of a reset malfunction Multiple bezel options allow for different aesthetic looks and accommodates various space requirements Optional bending terminal blades allow for use where space is at a premium Manufactured for harsh, rugged environments 2 sensing.honeywell.com

Features and Benefits EASY TO READ The large 7 mm display on LM Series hour meters/counters eases readability and offers options of backlight and running indicators. Great for tracking rental product use! RELIABLE AND DURABLE The LM Series IP67 (front)/ip66 (back) environmental sealing creates a rugged package design well suited for harsh environments. The mounting assembly s durable design helps make installation accurate and efficient. Their shock and vibration resistance allows for use in a wide variety of heavy-duty applications. Up to 40 years of data retention without power! CUSTOMIZABLE LM Series hour meters/counters can be customized with the customer s logo, as well as numerous customizable bezel options. Meters are offered with two function types: hour meter (measures time) or counter (measures number of instances, starts, etc.). Optional bending terminal blades allow for use where space is at a premium. Potential Applications TRANSPORTATION Monitors and records elapsed running time in Agricultural vehicles Blowers Engines Heavy-duty construction vehicles Heavy-duty trucks Material-handling equipment Mowers sensing.honeywell.com 3

LM Series Table 1. Specifications Characteristic Digital range hours Digital range counts Digital height Backlight color (optional) View angle Running indicator Accuracy Operating voltage range Sealing Shock Vibration Humidity Operating temperature Storage temperature Transient immunity Power consumption Panel mounting Start time Parameter 0 to 99,999.9 hours with auto turn over 0 to 999,999 counts with auto turn over 7 mm blue 12 o clock yes ±200 ppm/hour 9 V to 64 V dc/ac (50 Hz to 500 Hz); 50 Hz for counter enable IP67 (front); IP66 (back) 55 g per SAE J1378; 75 g per MIL-M-3917D 20 g per SAE J1378; 10 g per MIL-M-3917D 95 % non-condensing at 38 C [100.4 F] -40 C to 85 C [-40 F to 185 F] -50 C to 90 C [-58 F to 190 F] load dump yes inductive yes EMI yes reverse polarity yes 0.8 ma @ 12 Vdc multiple options, dependent upon bezel shape <1 s; if including all 8 check, then >1 s Material case Makroblend Material lens Lexan Case depth Termination 1.35 in (including terminals) 1/4 in blade (straight and bending); 3/16 in blade (straight and bending) 4 sensing.honeywell.com

Microcontroller Unit (MCU) LCD Hour Meters/Counters PRODUCT NOMENCLATURE LM H H F A S H XX Type LM Series MCU (Microcontroller H C Unit) LCD Hour Meter Function Type Hour meter Counter H S B W D C Shape and Bezel Shape: Diamond Bezel: Black Shape: Standard Shape: Round Bezel: Black Shape: Round Bezel: Chrome Shape: Diamond Bezel: None Shape: Rectangle Connector Definition + : Positive - : Negative F B : Backlight (blue) E : Enable + : Positive - : Negative 4 R : Reset E : Enable 3 + - : : Negative Positive E : Enable 2 + : Positive - : Negative A C M N Terminal Type 1/4 in blade 3/16 in blade 1/4 in bending blade 3/16 in bending blade S Voltage Range 9 Vdc/Vac to 64 Vdc/Vac H N T 1 Logo Type Honeywell No logo Hours indicator Customer s logo #1 2 Customer s logo #2 NOTE: Codes 1 to 9 and A to Z (except H, N, and T ) are defined for customers different logo/type requirements. Modification Code Multiple packaging and component options are recommended. Type 11: Bulk packing with wires and fasteners. Type 21: Box per product packing with wires and fasteners. Please refer to Honeywell modification code, or contact your Honeywell sales representative, or an authorized Honeywell Distributor. See Table 2 (below) for specific details. Table 2. Modification Codes Modification Code Product Shape Box/Meter Wrap/ Marking Hour Meter Terminal Wires 1 wire per terminal Fastenings 11 Included Diamond, 12 Bulk pack, no box No fastenings included Standard, 13 marking No wires Included Rectangle 14 included No fastenings included 21 Diamond, 1 wire per Included Box per product, 22 Standard, terminal No fastenings included box marked with 23 Rectangle, No wires Included part number 24 Round included No fastenings included 31 1 wire per Included 32 Bulk pack, no box terminal No fastenings included Round 33 marking No wires Included 34 included No fastenings included Product Qty Per Carton(s) 96 pieces per carton 24 pieces per carton 48 pieces per carton Instruction Sheet Qty 1 24 1 sensing.honeywell.com 5

LM Series LM SERIES ORDER GUIDE Catalog Listing Function Shape Bezel Connectors Terminal Type LM-CS3CS-N11 Counter Standard 3 3/16 in blade None LM-CS3CS-N13 Counter Standard 3 3/16 in blade None LM-CS3CS-N21 Counter Standard 3 3/16 in blade None LM-CS3CS-N22 Counter Standard 3 3/16 in blade None LM-CS3CS-N23 Counter Standard 3 3/16 in blade None Logo LM-CS4AS-N11 Counter Standard 4 (reset) 1/4 in blade None LM-HB2AS-H31 Hour Meter Round Black 2 1/4 in blade Honeywell LM-HB3AS-H31 Hour Meter Round Black 3 1/4 in blade Honeywell LM-HB4AS-H31 Hour Meter Round Black 4 (reset) 1/4 in blade Honeywell LM-HC3CS-H11 Hour Meter Rectangle 3 3/16 in blade Honeywell LM-HC3CS-H21 Hour Meter Rectangle 3 3/16 in blade Honeywell LM-HC3CS-H22 Hour Meter Rectangle 3 3/16 in blade Honeywell LM-HD2AS-H11 Hour Meter Diamond None 2 1/4 in blade Honeywell LM-HD2AS-N11 Hour Meter Diamond None 2 1/4 in blade None LM-HD2AS-N21 Hour Meter Diamond None 2 1/4 in blade None LM-HD2AS-N22 Hour Meter Diamond None 2 1/4 in blade None LM-HD3AS-H11 Hour Meter Diamond None 3 1/4 in blade Honeywell LM-HD3AS-H13 Hour Meter Diamond None 3 1/4 in blade Honeywell LM-HD3AS-N11 Hour Meter Diamond None 3 1/4 in blade None LM-HD4AS-H11 Hour Meter Diamond None 4 (reset) 1/4 in blade Honeywell LM-HD4AS-N11 Hour Meter Diamond None 4 (reset) 1/4 in blade None LM-HH2AS-H11 Hour Meter Diamond Black 2 1/4 in blade Honeywell LM-HH2AS-H21 Hour Meter Diamond Black 2 1/4 in blade Honeywell LM-HH2AS-H22 Hour Meter Diamond Black 2 1/4 in blade Honeywell LM-HH2AS-N11 Hour Meter Diamond Black 3 1/4 in blade None LM-HH3AS-H11 Hour Meter Diamond Black 3 1/4 in blade Honeywell LM-HH3AS-H21 Hour Meter Diamond Black 3 1/4 in blade Honeywell LM-HH3AS-H22 Hour Meter Diamond Black 3 1/4 in blade Honeywell LM-HH3AS-N11 Hour Meter Diamond Black 3 1/4 in blade None LM-HH4AS-H11 Hour Meter Diamond Black 4 (reset) 1/4 in blade Honeywell LM-HH4AS-H21 Hour Meter Diamond Black 4 (reset) 1/4 in blade Honeywell LM-HH4AS-H22 Hour Meter Diamond Black 4 (reset) 1/4 in blade Honeywell LM-HH4AS-N11 Hour Meter Diamond Black 4 (reset) 1/4 in blade None LM-HHFAS-H11 Hour Meter Diamond Black 4 (backlight) 1/4 in blade Honeywell LM-HHFAS-H21 Hour Meter Diamond Black 4 (backlight) 1/4 in blade Honeywell LM-HHFAS-H22 Hour Meter Diamond Black 4 (backlight) 1/4 in blade Honeywell 6 sensing.honeywell.com

Microcontroller Unit (MCU) LCD Hour Meters/Counters LM SERIES ORDER GUIDE, CONTINUED Catalog Listing Function Shape Bezel Connectors Terminal Type Logo LM-HS2AS-H11 Hour Meter Standard 2 1/4 in blade Honeywell LM-HS2AS-H21 Hour Meter Standard 2 1/4 in blade Honeywell LM-HS2AS-N21 Hour Meter Standard 2 1/4 in blade None LM-HS2AS-N22 Hour Meter Standard 2 1/4 in blade None LM-HS2AS-T11 Hour Meter Standard 2 1/4 in blade Hours indicator LM-HS3AS-H11 Hour Meter Standard 3 1/4 in blade Honeywell LM-HS3AS-H21 Hour Meter Standard 3 1/4 in blade Honeywell LM-HS3CS-N11 Hour Meter Standard 3 3/16 in blade None LM-HS4AS-H11 Hour Meter Standard 4 (reset) 1/4 in blade Honeywell LM-HSFAS-H11 Hour Meter Standard 4 (backlight) 1/4 in blade Honeywell LM-HW2AS-H31 Hour Meter Round Chrome 2 1/4 in blade Honeywell LM-HW3AS-H31 Hour Meter Round Chrome 3 1/4 in blade Honeywell LM-HW4AS-H31 Hour Meter Round Chrome 4 (reset) 1/4 in blade Honeywell sensing.honeywell.com 7

LM Series DIMENSIONAL DRAWINGS Figure 1. Diamond-Shaped Hour Meter Dimensions LENS: BACKGROUND BLACK WITH WHITE LETTERING 2.13 in 1.455 in 1.445 in1.75 in 0.957 in 4X R 0.030 in ±0.005 in LOGO 0.08 in 0.79 in 0.75 in 0.14 in 0.22 in ±0.02 in 1.35 in 10 RETAINER 0.955 in 0.945 in 1.25 in (0.33 in) (0.89 in) 0.18 in 2X Ø 0.15 in BENDING TERMINAL (OPTIONAL, CUSTOMER DEFINE) MOUNTING HOLE (1.41 in) CASE TERMINAL LABEL PRINTING: PART NO, VOLTAGE, DATE CODE, UL RECOGNIZED SYMBOL WITH (FILE NO) XXXXXX & CE SYMBOL, MAX POWER, PRODUCING AREA SHOULD BE PRINTED ON LABEL. TERMINALS TO ACCEPT GM TERMINAL 2962447 AND GM CONNECTOR 2962448 OR EQUIVALENT. Figure 2. Standard-Shaped Hour Meter Dimensions 1.79 in 1.60 in (0.957 in) 0.10 in 0.79 in 0.75 in 0.22 in ±0.02 in 10 1.44 in max. (0.44 in) 0.88 in (0.18 in) 1.08 in (0.330 in) 0.94 in max. 0.36 in BENDING TERMINAL (OPTIONAL, CUSTOMER DEFINE) Figure 3. Round-Shaped Hour Meter Dimensions STANDARD GEOMETRY TERMINALS TO ACCEPT GM TERMINAL 2962447 AND GM CONNECTOR 2962448 OR EQUIVALENT. Ø 2.00 in 0.12 in 0.30 in 1.33 in 0.98 in 0.73 in CUP RETAINER & HEX NUT & LOCKWASHER 1.44 in max. LOGO Ø 2.27 in (0.18 in) Ø 2.41 in 0.94 in max. BEZEL DIAL CASE 0.88 in (0.44 in) LABEL PRINTING: PART NO, VOLTAGE, DATE CODE, UL RECOGNIZED SYMBOL WITH (FILE NO) XXXXXX & CE SYMBOL, MAX POWER, PRODUCING AREA SHOULD BE PRINTED ON LABEL. TERMINALS TO ACCEPT GM TERMINAL 2962447 AND GM CONNECTOR 2962448 OR EQUIVALENT. 8 sensing.honeywell.com

Microcontroller Unit (MCU) LCD Hour Meters/Counters Figure 4. Rectangle-Shaped Hour Meter Dimensions 1.902 in 1.291 in 1.768 in 0.957 in 0.87 in 0.157 in 0.72 in Figure 5. Diamond-Shaped (No Bezel) Hour Meter Dimensions BACKGROUND BLACK WITH WHITE LETTERING 2.05 in 1.75 in (0.957 in) 1.35 in 0.79 in 1.44 in max. 0.75 in (0.88 in) 0.22 in 0.10 in ±0.02 in (0.44 in) 10 0.18 in 1.03 in (0.330 in) TERMINAL BENDING TERMINAL (OPTIONAL, CUSTOMER DEFINE) 0.94 in max. 2 X Ø 0.150 in holes CASE - BLACK TERMINALS TO ACCEPT GM TERMINAL 2962447 AND GM CONNECTOR 2962448 OR EQUIVALENT., CAUTION Be cautious when working around and connecting to the LM Series terminals, especially those other than the positive terminal (+) as there is no eletrical protection on the negative (-), reset, enable, and/or backlight terminals. sensing.honeywell.com 9

LM Series Figure 6. LM Series Mounting and Fasteners (if applicable) 10 sensing.honeywell.com

Microcontroller Unit (MCU) LCD Hour Meters/Counters ADDITIONAL INFORMATION The following associated literature is available on the Honeywell web site at sensing.honeywell.com: Product installation instructions Product range guide Product line guide Product application-specific information Case study: True time stamp hour meters Industrial product line card Application note: Sensors and switches for potential medical applications Application note: Sensors and switches in front loaders Application note: Sensors and switches in mobile cranes Appilcation note: Sensors and switches in oxygen concentrator applications WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. sensing.honeywell.com 11

Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell s sensing and control products, call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 006178-4-EN IL50 GLO April 2015 Copyright 2015 Honeywell International Inc. All rights reserved. Makroblend is a registered trademark of Bayer Aktiengesellschaft Lexan is a registered trademark of GE Plastics

Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Honeywell: LM-HB2AS-H31