Direct solenoid and solenoid pilot operated valves

Similar documents
Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Specifications 54 Series Valve

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

MAC VALVES, INC. Rev. T

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77

42 Series MAConnect TM. 42 Series Plug-In Manifold

92 Series MAConnect with Sub D

MAC Pulse Valve PV03 Series

External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right

MAC Pulse Valve PV06 Series

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP

82 Series MAConnect with Sub-D

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX

32, CONTENTS SMALL LARGE

MAC VALVES EUROPE, INC.

Directional Seat Valve Series D4S (Denison)

Bullet Valve (BV) Series

Bullet Valve (BV) Series

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

Chapter 10: Valves for Pipe Mounting

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

Rodless cylinders. Standard magnetic version. High reliability and long lifetime. Low friction and good resistance to loads

Series 581 ISO Pneumatic Directional Control Valves

ISO 5599/ Series Technical and Operating Data

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

Chapter 6: Check Valves

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:

Sc h rader Bellows. CS Series Air Control Valves. 2 & 3-Way, Inline, Manifold & Stacking Direct Acting Solenoid Valves

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

% ^ ) 4/2 SERIES. Direct Mount. Direct Acting Direct Mount Pilot Valves. Brass or Stainless Steel Bodies 1/4" NPT. Features. Construction.

Серия MAC Pulse Valve PV06

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

3 Port Solenoid Valve Direct Operated Poppet Type

I23 RD P 16N 00

Electrical Interface Dimensional Drawings Connector Kits

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

BULLET VALVE THINK GLOBAL ACT LOCAL. Our global distribution network is keeping your machines running around the clock around the world

FedEx Express Rates. Effective Sept. 15, 2008

2012 Series Solenoid Pilot Actuated Valves

NEW! MAXIMATIC SOLENOID VALVES

LYCOMING CYLINDER PRICING

Port Flow Rate/ Function Series Actuators Page Number Size Factor

5 Port Direct Operated Poppet Solenoid Valve, Rubber Seal

2002 Series Solenoid Air Pilot Actuated Valves

The Product Range. Technical Data

Proveedor Integral de Soluciones para la Industria. Desde1963

Control & Power, Inc

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN. Body ported VZ L

5 Port Solenoid Valve

Directional Control Valves. General Description. Features. Specifications

Series VZ Port Solenoid Valve Body Ported. How to Order VK VZ VF VFR VP4 VZS VFS VS4 VQ7 EVS VFN Type of actuation. Option.

The Price Alternative Pneumatic Cylinders and Slides

KRONES DIRECT REPLACEMENTS

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

General. Principles. 3-Trapped Key Switches. 11-Cat. No. Index. Logic. Power. Safety Switches Trapped Key Switches Overview

COILS, CONNECTORS, SOLENOID VALVES

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported. Flow characteristics 1 4/2 (P A/B) 4/2 5/3 (A/B R1/R2)

Simultaneous Electrical / Pneumatic Connection to Manifold 1/4 or 6mm Integral Push-In Fittings. AC or DC Circuit Board

Valvair Sprint TM Pneumatic Valves Solenoid & Pilot-Operated Directional Spool Valves. Catalog VAL-VS-E/USA April 2004

Contact Air Incorporated for further assistance. Ph:

3 Way/2 Position Valves

HERION. MINI ISO VALVES Size 18 mm, V40 / V41 SERIES Size 26 mm, V44 / V45 SERIES. Flexible subbase system with a wide range of accessories

5 Port Pilot Operated Solenoid Valve Metal Seal, Body Ported

2/2-way, 3/2-way NC and NO. Monostable - bistable (with magnetic memory) Ports M5 and G1/8 - cartridge ø4

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

5 Port Solenoid Valve Direct Operated Poppet Type. Specifications

Flow characteristics Max. (1) b Standard Specifications. P Manual override.

Rubber Seal 5 Port Pilot Type/Body Ported Type. Symbol. How to Order

nickel-plated brass - PBT technopolymer HNBR, FKM stainless steel

Mini 1. Compact High Flow 3-Way and 4-Way Pneumatic Directional Control Valves

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY!

Chapter 6: Check Valves

ROSS CONTROLS. Base Mounted Valves. and Serial Bus Communication

Grommet (G) (Standard) 100 VAC, 50/60 Hz 200 VAC, 50/60 Hz 24 VDC

Technical Data... 3 How to Order... 4 Dimensions... 5 Inline Mount Valve... 6 Manifold Dimensions and Part Numbers... 6

Section 2 Proportional Quick Exhaust

82610/ /2-way seat valves

3 Port Solenoid Valve Direct Operated Poppet Type 02 1 G VT325. For manifold: Enter VO. Valve option. Nil Standard V For vacuum Option.

2005 Series Solenoid Pilot Actuated Valves

Microbore Hose, Assemblies & accessories

2035 Series Solenoid Pilot Actuated Valves

Compact Proportional Solenoid Valve

TECHNICAL BULLETIN. The main focus of MAC Valves is to offer an innovative product developed according to users experience and that provides:

Exhausting equipment for pilot valve not required. Common exhaust port for main and pilot valve (VF1000/3000)

Complete Range of Movement Solutions

Transcription:

Direct solenoid and solenoid pilot operated valves Series ISO Individual mounting Valve only No base non plug-in Conform to ISO 99/ Valve only No base plug-in Conform to ISO 99/ Manifold mounting Valve only No base non plug-in Conform to ISO 99/ Valve only No base plug-in Conform to ISO 99/ Series 6 Bonded spool Balanced -way poppet Internal pilot supply Manual operator Large spool diameter External pilot supply 7 8 67 69 6 Air return 7 8P External pilot supply 8 00 9 SERIES FEATURES Plug-in (99/) and non plug-in (99/) models. -position, single or double operator. (Solenoid or Remote Air) -position, double solenoid, open center, closed center, and pressure center. Extended or recessed manual operators. Single pressure and dual pressure. Individual base or add-a-unit manifold base. Plug-in, sandwich, single and dual pressure regulators for both individual and manifold valves. 9 ISO 0 ISO 0 ISO ISO ISO 79 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO Function Port size Flow (Max) Individual/Manifold mounting Series /, / / - /8.8 C v No base non plug-in Valve only Conform to ISO 99/ OPERATIONAL BENEFITS. Unique patented Macsolenoid for fastest possible response times and virtually burnout proof AC solenoid operation.. Balanced poppet -way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service.. Large spool area for maximum shifting forces even at minimum operating pressure.. Very high flow in a compact package. HOW TO ORDER SINGLE PRESSURE MODELS Pilot air Internal External "" end DUAL PRESSURE MODELS Pilot air / Single operator MV-BA-AAAA-DM-DXXX-XXX MV-BA-AAAB-DM-DXXX-XXX 6. Plug-in design of valves, bases and regulators for modular assembly and ease of maintenance. 7. Internal or external pilot operation. Manifolds supplied with common external pilot. 8. Air only return. Optional memory spring is also available. 9. Optional low wattage DC solenoid down to.0 watt. / Double operator MV-BA-ABAA-DM-DXXX-XXX MV-BA-ABAB-DM-DXXX-XXX / Single operator / Closed center MV-BA-AEAA-DM-DXXX-XXX MV-BA-AEAB-DM-DXXX-XXX / Double operator / Open center MV-BA-AFAA-DM-DXXX-XXX MV-BA-AFAB-DM-DXXX-XXX / Pressure center 6 7 8 67 69 6 7 8P Internal pilot From port # MV-BA-ACAD-DM-DXXX-XXX MV-BA-ADAD-DM-DXXX-XXX MV-BA-AGAD-DM-DXXX-XXX 8 Internal pilot From port # External pilot From "" end MV-BA-ACAE-DM-DXXX-XXX MV-BA-ACAB-DM-DXXX-XXX MV-BA-ADAE-DM-DXXX-XXX MV-BA-ADAB-DM-DXXX-XXX MV-BA-AGAE-DM-DXXX-XXX MV-BA-AGAB-DM-DXXX-XXX 00 SOLENOID OPERATOR DM-D XXX-XXX * 9 XX Voltage X Lead wire length X Manual operator XX JA 0/0, 0/60 A 8 (Flying leads) Non-locking recessed KA JB 0/0, 0/60 B (Flying leads) Locking recessed KD JC /0, /60 J Connector JB FB VDC (.8W) JD DA VDC (.W) BA DF VDC (.7W) * Other options available, see page 09. Note: ISO series, valve and base are ordered separately, see page for base code. OPTIONS Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads 9 ISO 0 ISO 0 ISO ISO ISO Valve function : MV-BA-AXXX-XX-DXXX-XXX J for single operator universal spool (ext. pilot only) K for double operator universal spool (ext. pilot only) Pilot style : MV-BA-AXXX-DM-DXXX-XXX DM Pilot exhaust muffled DP Pilot exhaust piped (#0-) Spool return : MV-BA-AXAX-XX-DXXX-XXX A Standard return B Memory spring return 8 Consult Precautions page 7 before use, installation or service of MAC Valves..

00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS Series ISO TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with, W coil) Compressed air, vacuum, inert gases Internal pilot: 0 to 0 PSI External pilot : vacuum to 0 PSI Single/double operator : 0 to 0 PSI, positions : 0 to 0 PSI Not required, if used select a medium aniline point lubricant (between 80 F and 0 F) 0 µ 0 F to 0 F (-8 C to +0 C) /8": (.8 C v ) /": (.6 C v ) Class A continuous duty, # AWG x 8 leads -% to +0% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding:.8 VA = to.7 W Energize :. ms De-energize : 7.8 ms Options : Spare parts : Sandwich flow controls: FCPA-BA (screwdriver slot adjustment) FCPA-BB (locking knob adjustment) Sandwich regulator, see Regulators section Pilot valve: DMB-Dxxx-xxx Valve to base pressure seal: 666 DIMENSIONS Individual base Manifold base Dimensions shown are metric (mm) DOUBLE SOLENOID 7.9 6.9 SINGLE SOLENOID. 6.7 /8" COMMONS P..8..8 6.0.7..0.. /" NPSM CONDUIT 7. 67. 07.8 7. OPTIONAL COMMON EXTERNAL PILOT 86. 0.. 60. OPTIONAL BOTTOM PORTS 0. 69... Ø 6. TYP ().0. OPTIONAL BOTTOM PORT 60. 9.. 6. DIA. THRU () MTG HOLES 6. 8.6 7.8 6..7 6.0 0.0 7.. 8.0.. 00. 7. 77...6.. 0.0. 86.. 6. 8 Consult Precautions page 7 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Series ISO Function Port size Flow (Max) Individual/Manifold mounting Series /, / / - /8.8 C v No base plug-in Valve only Conform to ISO 99/ OPERATIONAL BENEFITS. Unique patented Macsolenoid for fastest possible response times and virtually burnout proof AC solenoid operation.. Balanced poppet -way pilot valve provides maximum shifting forces, precise repeatability and consistent operation.. MAC spool and bore combination wipes away contamination, eliminates sticking and allows for use on non-lube service.. Large spool area for maximum shifting forces even at minimum operating pressure.. Very high flow in a compact package. HOW TO ORDER SINGLE PRESSURE MODELS Pilot air Internal External "" end DUAL PRESSURE MODELS Pilot air / Single operator MV-PA-AAAA-DM-DXXP-XXX MV-PA-AAAB-DM-DXXP-XXX 6. Plug-in design of valves, bases and regulators for modular assembly and ease of maintenance. 7. Internal or external pilot operation. Manifolds supplied with common external pilot. 8. Air only return. Optional memory spring is also available. 9. Optional low wattage DC solenoid down to.0 watt. / Double operator MV-PA-ABAA-DM-DXXP-XXX MV-PA-ABAB-DM-DXXP-XXX / Single operator / Closed center MV-PA-AEAA-DM-DXXP-XXX MV-PA-AEAB-DM-DXXP-XXX / Double operator / Open center MV-PA-AFAA-DM-DXXP-XXX MV-PA-AFAB-DM-DXXP-XXX / Pressure center 6 7 8 67 69 6 7 8P Internal pilot From port # MV-PA-ACAD-DM-DXXP-XXX MV-PA-ADAD-DM-DXXP-XXX MV-PA-AGAD-DM-DXXP-XXX 8 Internal pilot From port # External pilot From "" end MV-PA-ACAE-DM-DXXP-XXX MV-PA-ACAB-DM-DXXP-XXX MV-PA-ADAE-DM-DXXP-XXX MV-PA-ADAB-DM-DXXP-XXX MV-PA-AGAE-DM-DXXP-XXX MV-PA-AGAB-DM-DXXP-XXX 00 SOLENOID OPERATOR DM-D XX P-XXX * 9 XX Voltage X Manual operator XX JA JB JC FB DA DF 0/0, 0/60 (.9W) 0/0, 0/60 (.9W) /0, /60 (.9W) VDC (.8W) VDC (.W) VDC (.7W) * Other options available, see page 09. Note: - ISO series, valve and base are ordered separately, see page for base codes. - Ground wire required for 0 volts or higher. OPTIONS Non-locking recessed Locking recessed DM DN DP DG Electrical connection Plug-in Plug-in with diode Plug-in with M.O.V. Plug-in with ground 9 ISO 0 ISO 0 ISO ISO ISO Valve function : MV-PA-AXXX-XX-DXXP-XXX J for single operator universal spool (ext. pilot only) K for double operator universal spool (ext. pilot only) Pilot style : MV-PA-AXXX-DM-DXXP-XXX DM Pilot exhaust muffled DP Pilot exhaust piped (#0-) Spool return : MV-PA-AXAX-XX-DXXP-XXX A Standard return B Memory spring return D Standard return with light E Memory spring return with light 8 Consult Precautions page 7 before use, installation or service of MAC Valves..

00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS Series ISO TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : (with, W coil) Compressed air, vacuum, inert gases Internal pilot: 0 to 0 PSI External pilot : vacuum to 0 PSI Single/double operator : 0 to 0 PSI, positions : 0 to 0 PSI Not required, if used select a medium aniline point lubricant (between 80 F and 0 F) 0 µ 0 F to 0 F (-8 C to +0 C) /8": (.8 C v ) /": (.6 C v ) Class A continuous duty, # AWG x base leads -% to +0% of nominal voltage Consult factory ~ Inrush 7.6 VA Holding:.8 VA = to.7 W Energize :0 ms De-energize : 9 ms Options : Spare parts : Sandwich flow controls: FCPA-AA (screwdriver slot adjustment) FCPA-AB (locking knob adjustment) Sandwich regulator, see Regulators section Pilot valve: DMB-DxxP-xxx Valve to base pressure seal: 666 DIMENSIONS Individual base Dimensions shown are metric (mm) Manifold base 08. " NPSM CONDUIT OPTIONAL COMMON EXTERNAL PILOT /8" 7.0. P..8..8.0. 6.9 6.0 COND 0. 9.7 0.9. 6.0 /" NPSM CONDUIT 07.8 7. 67. 7...7. 9. 90.7 9.0..8 8. 6. 0. /8" COMMONS TYP() OPTIONAL BOTTOM PORTS 0. 69... Ø 6. TYP (). 8.0.0.0 90. 70.7..7 8.0 0.0 6. 8.6.. 7. 77. 00. 7.8 6..7.6.0 OPTIONAL BOTTOM PORTS 90..0 6..0.0.9.0 Ø 6. THRU () MTG HOLES.0.0 8 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS Codification table for voltages / Manual operator / Electrical connection VALVE CODE -DM- D XX X-X XX - Pilot operated valves, 67, 9, 9, 00, ISO, ISO, ISO Series OPTIONS AVAILABLE FOR 09 Consult Precautions page 7 before use, installation or service of MAC Valves..

OPTIONS. VOLTAGE D-XX X-X XX VOLTAGE DA VDC (.W) DB VDC (.W) DC VDC (7.W) DD VDC (7.W) DE VDC (.7W) DF VDC (.7W) DK 0 VDC (.7W) DJ 8 VDC (.W) DL 6 VDC (6.0W) DM 6 VDC (.W) DN 6 VDC (6.0W) DR 90 VDC (6.6W) DS 0 VDC (7.W) DT 7 VDC (.6W) DP 8 VDC (.8W) FA VDC (.8W) FB VDC (.8W) FE VDC (.W) FF VDC (.W) JA 0/60, 0/0 (.9W) JB 0/60, 0/0 (.9W) JC /60, /0 (.7W) JD 00/60, 00/0, 0/60 (.9W) JE 0/60 (.W) JF 0/0 (.8W) JG 00/60, 00/0 (.9W). WIRE LENGTH D-XX X-X XX WIRE LENGTH 0 No wires A 8" B " C 6" D 8" E 7" F 96". ELECTRICAL CONNECTION D-XX X-X XX ELECTRICAL CONNECTION BA* Flying leads (grommet) BK* BA with protection diode BL* BA with protection varistor BM** Flying leads (solenoid plug-in) BN** BM with protection diode BP** BM with protection varistor BG** BM with ground BH** BM with protection diode & ground BJ** BM with protection varistor & ground CA* /" NPS conduit with flying leads CM* /" NPS metal conduit with flying leads CN* /" NPS metal conduit with flying leads & ground JB Rectangular connector JD JB with light JM Rectangular connector (male only) KA Mini square connector KB KA with protection diode KC KA with protection varistor KD KA with light KE KA with light and protection diode KF KA with light and protection varistor KG KA with light & diode KJ Mini square connector (male only) KK KJ with protection diode (male only) KL KJ with protection varistor (male only) TA Dual tabs with receptacles TB TA with protection diode TD TA with light TE TA with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode * From Lead wire length options choose A through F ** From Lead wire length options choose 0 through F Note: When coil is above 0 volts, a ground wire is required. Applies to options with flying leads.. MANUAL OPERATOR D-XX X-X XX MANUAL OPERATOR 0 No operator Non-locking recessed Locking recessed Non-locking extended Locking extended 0 Consult Precautions page 7 before use, installation or service of MAC Valves..

D i r e c t s o l e n o i d a n d s o l e n o i d p i l o t o p e r a t e d v a l v e s Series ISO Individual mounting Series valve only Manifold mounting valve only 00 Air/spring return Bonded flow seal spool Pilot air accumulator Manual operator 00 6 7 8 9 External pilot port 700 900 8 series features Fastest available response time with patented Macsolenoid. No-stick operation is ensured by wiping action of unique MAC spool/bore combination. Balanced poppet pilot valve for high flow, precise repeatability, and consistent operation. Large spool piston for high shifting force even at minimum operating pressure Air/spring return for consistent shifting on single solenoid models. Patented virtually burn-out proof AC solenoid. Optional low wattage DC solenoids down to.0 watt. Various manual operators & electrical connectors are available. Muffled or threaded pilot exhaust ports. Internal of external pilot models available. 7 Consult Precautions page 6 before use, installation or service of MAC Valves 600 600 6600 00 800 ISO ISO ISO MAC A MAC 0A MAC 00A

00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% M O N T H S Series ISO VALVE CONFIGURATIONS AVAILABLE -Pos., single or double operators (solenoid or remote air). Single or dual pressure. -Pos., double operator-closed center, open center or pressure center (solenoid or remote air). Individual base or add-a-unit manifold base. Internal pilot or external pilot (including a common external pilot or manifold models). Side porting and bottom porting options. *International Standards Organization ISO Common Base Interface (ISO Std. 99/) SPECIAL APPLICATION INSTRUCTIONS : On all models, energizing the "" operator (solenoid or remote air) connects Port # to Cylinder Port # and energizing the "" operator connects Port # to Cylinder Port #. For the following special applications, additional piping considerations are required. EXTERNAL PILOT APPLICATIONS* - An External Pilot Supply is only required when the main valve pressure is less than.8 BARS on single operators (soleneoid or remote air) or 0.7 BARS on double solenoid valves only. In these cases, use an External Pilot model and supply a minimum of.8 BARS for single operators or a minimum of 0.7 BARS for double solenoid valves to either the "" or "" External Pilot Port of the valve base. VACUUM APPLICATIONS - Use an External Pilot model as described above and also connect the vacuum source to Port # & and leave Port# open to atmosphere on single pressure models. On two pressure models, reverse the single pressure piping. SELECTOR APPLICATIONS - Use an External Pilot Model as described above if both pressures are below the minimum, otherwise use an Internal Pilot model and connect the higher pressure to Port # and the lower pressure to either Port # or depending on which Cylinder Port is to be active. TWO PRESSURE APPLICATIONS - For Internal Pilot models specify the model number for connecting either port # or, whichever is to be the higher pressure, to the Internal Pilot supply. For external Pilot models, pipe as described above for "External Pilot Application." *Note: Bar =. PSIG 8 Consult Precautions page 6 before use, installation or service of MAC Valves

D i r e c t s o l e n o i d a n d s o l e n o i d p i l o t o p e r a t e d v a l v e s Series ISO Function Port size Flow (Max) Individual mounting & Manifold mounting Series / - / / - /8.6 C v valve only operational benefits. Balanced spool, immune to variations of pressure.. Short stroke with high flow.. The piston (booster) provides maximum shifting forces.. Powerful return force thanks to the combination of mechanical and air springs.. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Pilot valve with balanced poppet, high flow, short and consistent response times. 8. Long service life. how to order Single pressure valves Pilot air / Single operator / Double operator / Closed center / Open center 00 00 6 7 8 9 Internal External MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ Dual pressure valves Pilot air / Single operator / Double operator / Pressure center 700 Internal port MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ 900 Internal port External MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ MV-AC-A-PM-XXYZZ 8 SOLENOID OPERATOR o p t i o n s XX Y ZZ * XX Voltage Y Manual operator ZZ Electrical connection 0/60, 0/0 Non-locking JB Rectangular connector 0/60, 0/0 Locking JD Rectangular connector with light /60, /0 JA Square connector 9 VDC (. W) JC Square connector with light 87 VDC (7. W) BA Flying leads (8 ) 6 VDC (8. W) * Other options available, see page 7. Note : Photo shown with JC connector. Note : ISO valves are delivered w/o base. See page 8 for base code. MV-AC-A-PM-XXYZZ - For CNOMO pilot, consult factory. - For universal spool replace by 6 ( position, sgl. pressure valves only) - For use with single pressure sandwich regulator, replace by. 9 Consult Precautions page 6 before use, installation or service of MAC Valves 600 600 6600 00 800 ISO ISO ISO MAC A MAC 0A MAC 00A

00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% M O N T H S Series ISO technical data Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow (at 6 bar, P=bar) : Leak rate : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases Internal pilot : single operator and positions : -0 PSI double operator : 0-0 PSI External pilot : vacuum to 0 PSI Single operator and positions : -0 PSI Double operator : 0-0 PSI Not required, if used select a medium aniline point lubricant (between 80 F to 0 F) 0 µ 0 F to 0 F (-8 C to 0 C) /" : (.6 C v ), /8" : (.6 C v ) 00 cm /min Epoxy encapsulated - class A wires - Continuous duty -% to +0% of nominal voltage Consult factory Inrush :.8 VA Holding : 0.9 VA = to 7. W VDC (8. W) Energize : 0 ms De-energize : ms 0/60 Energize : 7- ms De-energize : 0-7 ms Spare parts : Solenoid operator (power W) : D-XXAA, cover mounting screws 06 and seal 6. Pilot valve : PME-XXYZZ, including seal 67. Pressure seal between valve and base : 6. Mounting screw valve to base (x) : 0. dimensions Dimensions shown are metric (mm) INDIVIDUAL BASE A B 9, MANIFOLD BASE A B 9, C L 96, ISO Manifold mounting /8 EXTERNAL PILOT,0,0 6,0 /8 EXTERNAL PILOT,0 TYPE JA & JC JB & JD A 7.6 9.6 B 9.8 07. 00,0 6,0,0,0 0,0 8,0 /8 OPTIONAL PILOT EXH. 6,0 6,0,0 6,0, 0,0 /8 OPTIONAL PILOT EXHAUST,0,0 68,0,0 Ø 6, MTG HOLES,0,0 6,0 Ø 6, MTG HOLES ISO Individual mounting TYPE JA & JC JB & JD A 7.6 9.6 B 8.8 97. 0,0,0,0 0,0 8,0 00,0 9,0,0 6,0 OPTIONAL BOTTOM PORTS,7, OPTIONAL BOTTOM PORTS 60,0 00,0,0 6,0 8,0,7,0 ± 0, 60 Consult Precautions page 6 before use, installation or service of MAC Valves

B a s e s a c c o r d i n g t o I S O 9 9 Series ISO Series ISO ISO ISO HOW TO ORDER INDIVIDUAL BASE Port size Side ports Side & bottom ports Bottom cylinder ports and. Bottom inlet port / NPTF MB-AC- MB-AC- MB-AC- MB-AC- /8 NPTF MB-AC- MB-AC- MB-AC- MB-AC- MANIFOLD BASE Port size Side ports Bottom ports Bottom cylinder ports and. Bottom inlet port / NPTF MM-AC- MM-AC- MM-AC- MM-AC- /8 NPTF MM-AC- MM-AC- MM-AC- MM-AC- Manifold fastening kit : N-600-0. 8 Consult Precautions page 6 before use, installation or service of MAC Valves

00% 00% WARRANTY 8 OF PRODUCTION TESTED 00% MONTHS Series ISO DIMENSIONS Dimensions shown are metric (mm) Individual DIN 99/ Manifold /8 EXTERNAL PILOT /8 EXTERNAL PILOT,0,0 6,0 6,0 6,0 6,0,0,0 00,0 /8 PORTS 6,0 6,0,0 0,, 0,0, 6,0,0 68,0,0 Ø 6, MTG. HOLES,0,0 6,0 Ø 6, MTG. HOLES 0,0,0,0 9,0,0 6,0,7, 8,0,7,0 ± 0, VDMA 7, 8 G /" 0,0 8,0 00,0 0 0,, OPTIONAL BOTTOM PORTS, 98 OPTIONAL BOTTOM PORTS 8 60,0 00,0,0 0 6,0 0,, 86 Consult Precautions page 6 before use, installation or service of MAC Valves

O p t i o n s O P T I O N S Codification table for voltages / Manual operator / Electrical connection / Wire length VALVE CODE - XX Y ZZ (-VV) OPTIONS AVAILABLE FOR OPTIONS AVAILABLE FOR - valves type 00 Series - pilot valves "CNOMO" - valves type 00 Series - Pilot operated valves with pilots type 00 Series Series : - 6-700 - 800-900 - 600-600 - 6600-00 - ISO - ISO - ISO. - MAC - MAC 0 - MAC 00 - pilot operated valves with pilots type 00 Series Series : 00-7 - 8-9. - Pilot operated valves with pilots "CNOMO" Series : ISO - ISO - ISO 7 Consult Precautions page 6 before use, installation or service of MAC Valves

I n t r i n s i c a l l y S a f e V a l v e s Series ISO -- MV-AC ISO MV-AB ISO MV-AB ISO MAC ISO valves are built to International Standards Organization (ISO) Std. 99/. They are available in sizes; ISO, &. To select th ISO size required, insert the appropriate ISO number in the th position of the model code; EXAMPLE MV-AC for ISO, MV-AB for ISO, or MV-AB for ISO. Bases and manifolds must be ordered separately from the table below. HOW TO ORDER SOLENOID PILOT OPERATED VALVES LESS BASE SINGLE PRESSURE VALVES SGL. OPERATOR AIR/SPRING RETURN DBL. OPERATOR -POSITION PILOT SUPPLY DBL. OPER. -POS. CLOSED CENTER DBL. OPER. -POS. OPEN CENTER MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA Internal Pilot External Pilot External Pilot for use with Regulator MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA DUAL PRESSURE VALVES SGL. OPERATOR AIR/SPRING RETURN DBL. OPERATOR -POSITION PILOT SUPPLY DBL. OPER. -POS. PRESSURE CENTER MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA Int. Pilot-From Port Int. Pilot-From Port External Pilot MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA MV-AXB-A-FM-AJA SOLENOID PILOT VALVE OPTIONS XX - XXYZZ XX PILOT EXHAUST XX DC VOLTAGE Y MANUAL OPERATOR ZZ EXTERNAL PLUG-IN ZZ ENCLOSURE FM Muffled exhaust FP Piped exhaust A VDC (0.6 W) A6 VDC (0.6 W) 0 No operator Non-locking Recessed (std.) Locking Recessed Non-locking Extended Locking Extended JA Square without light (on solenoid) JB Rectangular without light (on solenoid) JE Square without light (on body) JF Rectangular without light (on body) AA JIC w//" NPS Conduit BA Grommet CA Conduit /" NPS CC Conduit /" NPT (CSA Threads) BASE TABLE ISO TYPE PORT SIZE INDIVIDUAL BASE MANIFOLD BASE BSPP NPTF BSPP NPTF ISO /" MB-AC- MB-AC- MM-AC- MM-AC- /8" MB-AC- MB-AC- MM-AC- MM-AC- ISO /8" MB-AB- MB-AB- MM-AB- MM-AB- /" MB-AB- MB-AB- MM-AB- MM-AB- ISO /" MB-AB- MB-AB- MM-AB- N/A /" MB-AB- MB-AB- MM-AB- N/A For manifold bases a common external pilot port is available. One connection only is required for all valves in the manifold whether single or double solenoid. Bottom ports are also available; consult factory for ordering information for these options. MANIFOLD FASTENING KIT For each gang, one kit is required. To order specify par number N-600-0. Consult Precautions page 6 before use, installation or service of MAC Valves

O P T I O N S Used on valve series: 00,, 6, 700, 800, 900, 600, 600, 6600, 00, MVAC, MVAB, MVAB, MAC, MAC0, MAC00. - XX Y ZZ VOLTAGE. VOLTAGE (00 Serie type coil) 0/60, 0/0 0/60, 0/0 00/60, 00/0 00/60, 00 /0 6 0/60 0 6/60 /0, /60 /60, /0 /60, /0 8/60, /0 6* 80/0, 0/0, 0/60, 80/60 9 0/60 7/0, 0/0 8/0 6 6/60 B /0 0 VDC (6 W) VDC ( W) VDC ( W) VDC (6 W) 7 VDC (. W) 9 VDC (. W) 60 VDC (8. W) 6 VDC (8. W) 6 6 VDC (6 W) 6 VDC (7 W) 66 8 VDC (.8 W) 67 6 VDC (7. W) 68 0 VDC (6. W) 69* 0 VDC (8.7 W), 0 VDC (. W) 7 90 VDC (8.8 W) 76* 00 VDC (6.9 W) 8* VDC (0.9 W) 87* VDC (7. W) 88* VDC (7. W) 89* 6 VDC (8.8 W) 90 8 VDC (8. W) 9* 6 VDC (0.6 W) 9 90 VDC (6. W) 9 VDC (7 W) 9 8 VDC (6. W) A VDC ( W) A VDC ( W) A 9 VDC ( W) MOD. DD0 : Protection diode (DC) - MAX. 8.W MOD. MOV : Protection varistor (AC) - MAX. 8.W * Voltages are CLSF only Used on valve series: 00, 7, 8, 9.. VOLTAGE (00 Serie type coil) - XX Y ZZ VOLTAGE 0/60, 0/0, VDC (6 W) 0/60, 0/0 00/60, 00/0 00/60, 00/0 0 6/60 /60 /60, /0 /60, /0 8/60, /0 0/0 6 80/60, 0/0 7 7/60 8 /0 9 0/60 0 80/0 0/60, 0/0 0/60, 0/0 600/60 7/0 8/0 0 VDC (6 W) VDC (. W) VDC (. W) VDC (.0 W) VDC (6 W) 7 VDC (. W) 8 8 VDC (. W) 60 VDC (9. W) 6 VDC (8. W) 6 6 VDC (8. W) 6 VDC (0 W) 66 8 VDC (. W) 67 6 VDC (0. W) 68 0 VDC (. W) 69 0 VDC (9. W) 7 8 VDC (8. W) 7 VDC ( W) 7 98 VDC (0 W) 7 7 VDC (. W) 7 90 VDC (. W) 76 00 VDC (9 W) 77 0 VDC (0 W), 0 VDC (.6 W) 78* VDC ( W) 80 VDC (0.6 W) 8 70 VDC (. W) 8 VDC (8. W) 8 VDC (0 W) 86 6 VDC ( W) 9* VDC ( W) 8 Consult Precautions page 6 before use, installation or service of MAC Valves

O p t i o n s O P T I O N S. MANUAL OPERATOR (Common options for 00 & 00 Series type coils) - XX Y ZZ MANUAL OPERATOR 0 No operator * No Operator with Light Non-locking recessed 6* Non-Locking Recessed with Light Locking recessed 7* Locking Recessed with Light Non-locking extended 8* Non-Locking Extended with Light Locking extended 9* Locking Extended with Light * Lights used with AA electrical connection. ELECTRICAL CONNECTION (00 Serie type coil) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with /" NPS conduit BA Flying leads CA /" NPS conduit CC /" NPT conduit FA Military type PIN GA Military type PIN HA AA with ground wire JA* Square connector JB Rectangular connector JC* Square connector with light JD Rectangular connector with light JE Square connector on top (ISO, ISO) JF Rectangular connector on top (ISO, ISO, ISO) JG JE with light JH JF with light JJ Square connector, male only JM Rectangular connector, male only MA Electrical common conduit (00 Series-Manifold/900 Series) MB Electrical common conduit (00 Series-Stacking/700 Series) NA CA with ground wire NC CC with ground wire RA /8" NPS conduit * Not to be used with 00, 800 and 900 Series manifold mounting. ELECTRICAL CONNECTION (00 Serie type coil) - XX Y ZZ ELECTRICAL CONNECTION AA Wiring box with /" NPS conduit BA Flying leads CA /" NPS conduit CC /" NPT conduit EA Explosion proof (00 Series) EA Explosion proof (7, 8 & 9 Series) FA Military type PIN GA Military type PIN HA AA with ground wire JA* Square connector JC Square connector with light JJ Square connector, male only NA CA with ground wire NC CC with ground wire 9 Consult Precautions page 6 before use, installation or service of MAC Valves