Direct solenoid and solenoid pilot operated valves

Similar documents
Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

GM - G XXX-XXX. Direct solenoid and solenoid pilot operated valves. Function Port size Flow [Max] Individual mounting. Series 77

Direct solenoid and solenoid pilot operated valves

Direct solenoid and solenoid pilot operated valves

Specifications 54 Series Valve

Direct solenoid and solenoid pilot operated valves

MAC VALVES, INC. Rev. T

Introduction Section 1 Section 2 Section 3 Section 4 Section 5 Section 6 Section 7

Direct solenoid and solenoid pilot operated valves

MAC Pulse Valve PV03 Series

MAC Pulse Valve PV06 Series

33 SERIES 34 SERIES 34B/C - X X X - G XX X - X XX A - X X X - R XX X - X XX

92 Series MAConnect with Sub D

External Pilot Models 5 Sgl. Sol. Plug-In to Left. Internal Pilot Models 1 Sgl. Sol. Plug-In to Left. 4 Dbl. Sol. Plug-In to Right

32, CONTENTS SMALL LARGE

42 Series MAConnect TM. 42 Series Plug-In Manifold

SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices. Orifice plate with annular chambers. 4/358 Siemens FI

Bullet Valve (BV) Series

Bullet Valve (BV) Series

82 Series MAConnect with Sub-D

Table 1d - FSA for All Returns, Females Tax Year

Rodless cylinders. Standard magnetic version. High reliability and long lifetime. Low friction and good resistance to loads

TM ETRS-TM35FIN-ETRS89 WTG

Directional Seat Valve Series D4S (Denison)

BC. Materials. Working temperature (Seals) Sectors: Industrial, Agricultural

SERVICE INSTRUCTION. All Certified Lycoming direct drive engines. TIME OF COMPLIANCE: At owner s discretion.

FedEx Express Rates. Effective Sept. 15, 2008

SERVICE INSTRUCTION. 652 Oliver Street Williamsport, PA U.S.A. Tel Fax

VACUUM PRESSURE PUMPS INSTALLATION CAUTIONS AND INFORMATION READ AND FOLLOW CAREFULLY!

Серия MAC Pulse Valve PV06

7. Are you upgrading a complete engine from a TCM/ Bendix to a Slick system? If yes, purchase a complete Slick Ignition Upgrade Kit.

MCC omponents Itasca Street Chatsworth

MAC VALVES EUROPE, INC.

General. Principles. 3-Trapped Key Switches. 11-Cat. No. Index. Logic. Power. Safety Switches Trapped Key Switches Overview

EtherNet/IP EtherCAT POWERLINK PROFINET Modbus/TCP

Multiplication Tables of Various Bases

AUTUMN 2013 TIME SCHEDULE

LYCOMING CYLINDER PRICING

Grade boundaries June 2018 exams. GCSE Reformed (subjects which use the 9 to 1 grade scale)

BULLET VALVE THINK GLOBAL ACT LOCAL. Our global distribution network is keeping your machines running around the clock around the world

The Product Range. Technical Data

DATE: May 19, 2000 Service Instruction No. 1443E (Supersedes Service Instruction No. 1443D) Engineering Aspects are FAA Approved

MCC SMBJ5.0 THRU SMBJ440CA. Features. Transient Voltage Suppressor 5.0 to 440 Volts 600 Watt. Mechanical Data

INSTRUMENT PANEL CLUSTERS

CUSTOM ADD-ONS FOR ENGLISH UNITS

Parts List, Wiring Diagrams

Chapter 10: Valves for Pipe Mounting

List of system parts and belonging Descriptive Documents


SITRANS F flowmeters. SITRANS F O delta p - Primary differential pressure devices Metering pipe with orifice plate and annular chambers 4/369

and zero rpm. Maximum recommended pressure is 110 psi (7.6 bar). Adjustment for speed is explained under Selection Procedure.

SST-90 LED Binning and Labeling

Type E-10, E-11 Hazardous Area Explosion-proof Transmitters

3/8 & 1/2 NPT. with 3/8 and 1/2 NPT ports for 4 Way - 2 & 3 Position see Pg locate counterbores in body to control static squeeze on seals.

MOONEY INTERNATIONAL CORPORATION The Symbol of Performancet MOONEY SPECIAL LETTER Date:

Airflex CB Construction Section B

DATE: February 13, 2019 Service Instruction No. 1037V (Supersedes Service Instruction No. 1037U) Engineering Aspects are FAA Approved

VSD10M DIRECTIONAL CONTROL VALVES SOLENOID ACTUATED, PILOT OPERATED

PRODUCT GROUP WEIGHT MIN ORDER

SMB5.0A(CA) - SMB440A(CA)

SAMYANG ELECTRONICS SMBJ SMBJ440CA TRANSIENT VOLTAGE SUPPRESSOR. Features. Mechanical Characteristics

ROTARY SHAFT / OIL SEALS GASKETS LINER RINGS REPAIR KITS BONDED SEALS O RINGS. Automotive Seals VW BARNWELL THE SEAL OF APPROVAL

Chapter 6: Check Valves

ISO 5599/ Series Technical and Operating Data

SPARE CONNECTORS 2008

SMA6J5.0A(CA) - SMA6J440A(CA)

Vacuum Automation 2.1. The future depends on good product choices

Safety 14 ga. Welded Plastic Bin Security Fire Resistant Gas Cylinder


CFR Series. Power Inductors OUTLINE FEATURES APPLICATIONS SPECIFICATIONS MITSUMI

KNOCK CYLINDERS CONTENTS ACTUATORS GENERAL CATALOG. Caution KNOCK CYLINDERS

2/2-way and 3/2-way Normally Closed (NC) and Normally Open (NO)

Directional Control Valves. General Description. Features. Specifications

REV: 000. Super Seca Flash Cure Units

Series 581 ISO Pneumatic Directional Control Valves

SMB. Features. Mechanical Characteristics. Maximum Ta=25 unless otherwise specified. Peak Pulse Power Dissipation by10/1000μs Test Waveform

Heavy Duty Actuators CONTROLS. Pneumatic Actuators for Quarter-Turn Valves and Dampers Torques to 1,600,000 in. lbs. Double Acting and Spring Return

Microbore Hose, Assemblies & accessories

Sierra Differential

Constricting Type Clutches and Brakes

AENOR Product Certificate

Contact Air Incorporated for further assistance. Ph:

Field Variable Area Flowmeters BFP Global Purgemaster

Installation, Maintenance & Parts Manual

Stars or starlets? Competitor overview switching devices. Only for internal use. sirius IN COMPARISON

Genuine Metaris Gear Product Technical Catalog. Pumps & Components - MH Series Bearing & Bushing Style

There are many pre-designs of Vulkan launcher.

CAT. No. KS-570E. SCS Single Action Push Type. SCD Double Action Type. super. cylinder FUJIKURA RUBBER LTD.

3/8 & 1/2 NPT. 4-Way - 5 Ported - 2 Position - Type 2 Use on all 4 Way - 2 Position applications

IEC CONTACTORS. Contacts Model List Model List AC3 UL 115 V 230 V 200 V 230 V 460 V 575 V NO NC Number Price Number Price 3RT101

International standard flanges acc.to SAE, ISO, DIN, GOST. [bar] 0,5 (7.3 PSI)

Flow Measurement SITRANS F O delta p - Primary differential pressure devices

Transcription:

Direct solenoid and solenoid pilot operated valves Individual mounting Series Inline Sub-base non plug-in 4 6 Air return Manual operator Solenoid 4-way pilot with balanced poppet Bonded spool 2 7 8 2 67 69 44 46 42 47 48P 48 400 92 SERIES FEATURES Patented MACSOLENOID for fastest possible response times and virtually burn-out proof AC solenoid operation. Optional low watt DC solenoids. Various manual operators. Optional memory spring. 2 position or position valve configurations. or external pilot. 9 ISO 0 ISO 02 ISO ISO 2 ISO 9 Consult Precautions page 27 before use, installation or service of MAC Valves..

00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS SPOOL CONFIGURATIONS INTERNAL PILOT EXTERNAL PILOT EXT. PILOT PORT 2 4 2 4 SINGLE OPERATOR - SINGLE INLET SHOWN WITH 2 OPERATOR ENERGIZED SINGLE OPERATOR - SINGLE INLET SHOWN WITH 2 OPERATOR ENERGIZED INTERNAL PILOT (FROM # PORT) INTERNAL PILOT 2 4 2 4 SINGLE OPERATOR - DUAL INLET SHOWN WITH 2 OPERATOR ENERGIZED POSITION CLOSED CENTER INTERNAL PILOT INTERNAL PILOT 2 4 2 4 POSITION OPEN CENTER POSITION PRESSURE CENTER 40 Consult Precautions page 27 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Individual mounting Series /2, / /8 - /4.0 C v Inline OPERATIONAL BENEFITS. The 4-way pilot develops maximum shifting forces both ways. 2. Memory spring available.. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow.. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Long service life. HOW TO ORDER SINGLE PRESSURE MODELS Port size Pilot air /2 Single operator 4A-A0A-XX-XXXX-XXX 4A-B0A-XX-XXXX-XXX 4A-A0B-XX-XXXX-XXX 4A-B0B-XX-XXXX-XXX /2 Double operator 42A-A0A-XX-XXXX-XXX 42A-B0A-XX-XXXX-XXX 42A-A0B-XX-XXXX-XXX 42A-B0B-XX-XXXX-XXX / Closed center 2 4 4A-A0A-XX-XXXX-XXX 4A-B0A-XX-XXXX-XXX 4A-A0B-XX-XXXX-XXX 4A-B0B-XX-XXXX-XXX DUAL PRESSURE MODELS (INTERNAL PILOT PILOT PRESSURE SUPPLY FROM # PORT) Port size Pilot air /2 Single operator / Open center 2 4 46A-A0A-XX-XXXX-XXX 46A-B0A-XX-XXXX-XXX 46A-A0B-XX-XXXX-XXX 46A-B0B-XX-XXXX-XXX /2 Double operator / Pressure center 2 4 47A-A0A-XX-XXXX-XXX 47A-B0A-XX-XXXX-XXX 47A-A0B-XX-XXXX-XXX 47A-B0B-XX-XXXX-XXX 4 6 2 7 8 2 67 69 44 46 42 47 48P 48 SOLENOID OPERATOR 4A-A0A-XX-XXXX-XXX 4A-B0A-XX-XXXX-XXX 4A-A0B-XX-XXXX-XXX 4A-B0B-XX-XXXX-XXX DM-D XXX-XXX * XX Voltage X Wire length X Manual operator XX JA 0/0, 20/60 (2.9W) A 8 (Flying leads) Non-locking recessed KA JB 220/0, 240/60 (2.9W) B 24 (Flying leads) KD JC 24/60 (2.9W) J Connector JB FB 24 VDC (.8W) JD DA 24 VDC (.4W) DF 24 VDC (2.7W) BA SOLENOID OPERATOR GM-G XXX-XXX ** 44A-A0A-XX-XXXX-XXX 44A-B0A-XX-XXXX-XXX 44A-A0B-XX-XXXX-XXX 44A-B0B-XX-XXXX-XXX Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads 400 92 9 ISO 0 ISO 02 ISO ISO 2 ISO XX Voltage X Wire length X Manual operator XX DC DD DF 24VDC (.8W) 24VDC (2.W) 24VDC (4.0W) * Other options available, see page 09. ** Other options available, see page. A 8 B 24 C 6 Non-locking recessed BA BT KA KT Electrical connection Flying leads Flying leads with light Plug-in wire assy. Plug-in wire assy. with light 4 Consult Precautions page 27 before use, installation or service of MAC Valves..

7 00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases pilot 2 pos. : 20 to 20 PSI (with memory spring: 0 to 20 PSI) pos.: to 20 PSI pilot : vacuum to 20 PSI 2 position: 20 to 20 PSI (with memory spring: 0 to 20 PSI) position: to 20 PSI Not required, if used select a medium aniline point lubricant (between 80 F and 20 F) 40 µ 0 F to 20 F (-8 C to +0 C).0 C v Class A continuous duty, #22 AWG x 2 leads wires -% to +0% of nominal voltage Consult factory ~Inrush : 0.9 VA Holding : 7.7 VA =.8 to 2.7 W 24 V=/.4W Energize : 7. ms De-energize :. ms 20/60 Energize : 8-2 ms De-energize : 7- ms Options : Spare parts : BSPP threads Namur interface (specify mod. 080 after model) 4A-A0A-XX-XXXX-XXX Dual pressure models, replace by C for pilot supply from # port For memory spring, replace by 4 (single operator models only) Replace by 8 for position dual pressure, pressure center DM pilot body pressure seal: 642 DM pilot spacer plate: 2468-0. DIMENSIONS.2 DIA. MTG. HOLES, TYP.(2) 2.0 DOUBLE PILOT (DM) SIMPLE 96.0 PILOT (DM) Dimensions shown are metric (mm) 22.0 2.0 4. PILOT W/ DM SOLENOID PILOT W/ GM SOLENOID. 2 4 7.8 9. 8.7 44.0 9.0 0. PILOT W/ DM SOLENOID PILOT W/ GM SOLENOID 7. DOUBLE PILOT W/ PLUG-IN (GM) SINGLE PILOT W/ PLUG-IN (GM) 02. DOUBLE PILOT.0 W/ FLYING LEADS (GM) OPTIONAL MANUAL OPERATOR SINGLE PILOT W/ FLYING LEADS (GM) 99.0 7.0 4.2 DIA. MTG. HOLES, TYP.(2) 60.2 PILOT W/ GM SOLENOID 26.0 62. PILOT W/ DM SOLENOID.0 2.0 0. 9.8 42.7.2 PILOT W/ GM SOLENOID PILOT W/ DM SOLENOID 8.0 8.0 4.0 4. PILOT W/ DM SOLENOID PILOT W/ GM SOLENOID 42 Consult Precautions page 27 before use, installation or service of MAC Valves..

Direct solenoid and solenoid pilot operated valves Function Port size Flow (Max) Individual mounting Series /2, / /8 - /4.0 C v Sub-base non plug-in OPERATIONAL BENEFITS. The 4-way pilot develops maximum shifting forces both ways. 2. Memory spring available.. Balanced spool, immune to variations of pressure, also provides high flow. 4. Short stroke with high flow.. Bonded spool with minimum friction, shifting in a glass-like finished bore. 6. Wiping effect eliminates sticking. 7. Long service life. HOW TO ORDER SINGLE PRESSURE MODELS Port size Valve only Pilot air /2 Single operator 4A-00A-XX-XXXX-XXX 4A-00D-XX-XXXX-XXX 4A-AAA-XX-XXXX-XXX 4A-BAA-XX-XXXX-XXX 4A-AAD-XX-XXXX-XXX 4A-BAD-XX-XXXX-XXX /2 Double operator 42A-00A-XX-XXXX-XXX 42A-00D-XX-XXXX-XXX 42A-AAA-XX-XXXX-XXX 42A-BAA-XX-XXXX-XXX 42A-AAD-XX-XXXX-XXX 42A-BAD-XX-XXXX-XXX / Closed center 2 4 4A-00A-XX-XXXX-XXX 4A-00D-XX-XXXX-XXX 4A-AAA-XX-XXXX-XXX 4A-BAA-XX-XXXX-XXX 4A-AAD-XX-XXXX-XXX 4A-BAD-XX-XXXX-XXX DUAL PRESSURE MODELS (INTERNAL PILOT PILOT PRESSURE SUPPLY FROM # PORT) Port size Pilot air /2 Single operator / Open center 2 4 46A-00A-XX-XXXX-XXX 46A-00D-XX-XXXX-XXX 46A-AAA-XX-XXXX-XXX 46A-BAA-XX-XXXX-XXX 46A-AAD-XX-XXXX-XXX 46A-BAD-XX-XXXX-XXX / Pressure center 2 4 47A-00A-XX-XXXX-XXX 47A-00D-XX-XXXX-XXX 47A-AAA-XX-XXXX-XXX 47A-BAA-XX-XXXX-XXX 47A-AAD-XX-XXXX-XXX 47A-BAD-XX-XXXX-XXX /2 Double operator 4 6 2 7 8 2 67 69 44 46 42 47 48P 48 Valve only SOLENOID OPERATOR 4A-00A-XX-XXXX-XXX 4A-00D-XX-XXXX-XXX 4A-AAA-XX-XXXX-XXX 4A-BAA-XX-XXXX-XXX 4A-AAD-XX-XXXX-XXX 4A-BAD-XX-XXXX-XXX DM-D XXX-XXX * XX Voltage X Wire length X Manual operator XX JA 0/0, 20/60 (2.9W) A 8 (Flying leads) Non-locking recessed KA JB 220/0, 240/60 (2.9W) B 24 (Flying leads) KD JC 24/60 (2.9W) J Connector JB FB 24 VDC (.8W) JD DA 24 VDC (.4W) DF 24 VDC (2.7W) BA SOLENOID OPERATOR GM-G XXX-XXX ** 44A-00A-XX-XXXX-XXX 44A-00D-XX-XXXX-XXX 44A-AAA-XX-XXXX-XXX 44A-BAA-XX-XXXX-XXX 44A-AAD-XX-XXXX-XXX 44A-BAD-XX-XXXX-XXX Electrical connection Square connector Square connector with light Rectangular connector Rectangular connector with light Flying leads 400 92 9 ISO 0 ISO 02 ISO ISO 2 ISO XX Voltage X Wire length X Manual operator XX DC DD DF 24VDC (.8W) 24VDC (2.W) 24VDC (4.0W) * Other options available, see page 09. ** Other options available, see page. A 8 B 24 C 6 Non-locking recessed BA BT KA KT Electrical connection Flying leads Flying leads with light Plug-in wire assy. Plug-in wire assy. with light 4 Consult Precautions page 27 before use, installation or service of MAC Valves..

2 TO 20 PSI 00% 00% WARRANTY 8 O F P R O D U C T I O N T E S T E D 00% MONTHS TECHNICAL DATA Fluid : Pressure range : Pilot pressure : Lubrication : Filtration : Temperature range : Flow : Coil : Voltage range : Protection : Power : Response times : Compressed air, vacuum, inert gases pilot 2 pos. : 20 to 20 PSI (with memory spring: 0 to 20 PSI) pos.: to 20 PSI pilot : vacuum to 20 PSI 2 position: 20 to 20 PSI (with memory spring: 0 to 20 PSI) position: to 20 PSI Not required, if used select a medium aniline point lubricant (between 80 F and 20 F) 40 µ 0 F to 20 F (-8 C to +0 C).0 C v Class A continuous duty, #22 AWG x 2 leads wires -% to +0% of nominal voltage Consult factory ~Inrush : 0.9 VA Holding : 7.7 VA =.8 to 2.7 W 24 V=/.4W Energize : 7. ms De-energize :. ms 20/60 Energize : 8-2 ms De-energize : 7- ms Options : BSPP threads 4A-AAA-XX-XXXX-XXX Dual pressure models, replace by C for pilot supply from # port For flow control, replace by B For memory spring, replace by 6 Base only : 400A-XXX (i.e. 400A-AAA) Spare parts : Body to base seal: 62 Flow control assembly: N-0400 Body mounting screws (x2): 04. DIMENSIONS Dimensions shown are metric (mm) 86.2 EXTENDED OPERATOR 97.9 LOCKNING OPERATOR 8.4 C L C L 2 4 9.0 STOCK REF..0 20.0 08. SINGLE PILOT /8" - 27 N.P.T.F. /4" - 8 N.P.T.F. TYPICAL OPTIONAL FLOW CONTROL 2.0 DOUBLE PILOT 62.0.0 2 4 0.0 8. 2 4 2 4 28.0..9 9. REF. 4.0 DIA. (2) MIG. HOLES.0 47.00 OPTIONAL EXTERNAL PILOT PORT (#0-2 UNF-28) 26. 44 Consult Precautions page 27 before use, installation or service of MAC Valves..

OPTIONS Codification table for voltages / Manual operator / Electrical connection VALVE CODE -DM- D XX X-X XX 2 4 - Pilot operated valves 2, 67, 92, 9, 400, ISO, ISO2, ISO Series OPTIONS AVAILABLE FOR 09 Consult Precautions page 27 before use, installation or service of MAC Valves..

OPTIONS. VOLTAGE D-XX X-X XX VOLTAGE DA 24 VDC (.4W) DB 2 VDC (.4W) DC 2 VDC (7.W) DD 24 VDC (7.W) DE 2 VDC (2.7W) DF 24 VDC (2.7W) DK 0 VDC (4.7W) DJ 28 VDC (.2W) DL 64 VDC (6.0W) DM 6 VDC (.W) DN 6 VDC (6.0W) DR 90 VDC (6.6W) DS 0 VDC (7.W) DT 7 VDC (.6W) DP 48 VDC (.8W) FA 2 VDC (.8W) FB 24 VDC (.8W) FE 2 VDC (2.4W) FF 24 VDC (2.4W) JA 20/60, 0/0 (2.9W) JB 240/60, 220/0 (2.9W) JC 24/60, 24/0 (.7W) JD 00/60, 00/0, 0/60 (.9W) JE 220/60 (.4W) JF 240/0 (2.8W) JG 200/60, 200/0 (.9W) 2. WIRE LENGTH D-XX X-X XX WIRE LENGTH 0 No wires A 8" B 24" C 6" D 48" E 72" F 96" 4. ELECTRICAL CONNECTION D-XX X-X XX ELECTRICAL CONNECTION BA* Flying leads (grommet) BK* BA with protection diode BL* BA with protection varistor BM** Flying leads (solenoid plug-in) BN** BM with protection diode BP** BM with protection varistor BG** BM with ground BH** BM with protection diode & ground BJ** BM with protection varistor & ground CA* /2" NPS conduit with flying leads CM* /2" NPS metal conduit with flying leads CN* /2" NPS metal conduit with flying leads & ground JB Rectangular connector JD JB with light JM Rectangular connector (male only) KA Mini square connector KB KA with protection diode KC KA with protection varistor KD KA with light KE KA with light and protection diode KF KA with light and protection varistor KG KA with light & diode KJ Mini square connector (male only) KK KJ with protection diode (male only) KL KJ with protection varistor (male only) TA Dual tabs with receptacles TB TA with protection diode TD TA with light TE TA with light and protection diode TJ Dual tabs (male only) TK TJ with protection diode TM TJ with light TN TJ with light and protection diode * From Lead wire length options choose A through F ** From Lead wire length options choose 0 through F Note: When coil is above 0 volts, a ground wire is required. Applies to options with flying leads.. MANUAL OPERATOR D-XX X-X XX MANUAL OPERATOR 0 No operator Non-locking recessed Non-locking extended 4 Locking extended 0 Consult Precautions page 27 before use, installation or service of MAC Valves..

OPTIONS Codification table for voltages / Manual operators / Electrical connections VALVE CODE -GM- G XX X-X XX 2 4 OPTIONS AVAILABLE FOR - Solenoid valves 2 & 400 Series Consult Precautions page 27 before use, installation or service of MAC Valves..

OPTIONS. VOLTAGE 4. ELECTRICAL CONNECTION G-XX X-X XX VOLTAGE DC 24 VDC (.8 W) DD 24 VDC (2. W) DE 24 VDC (.0 W) DF 24 VDC (4.0 W) DJ 2 VDC (.8 W) DK 2 VDC (2. W) DM 2 VDC (.0 W) DN 2 VDC (4.0 W) G-XX X-X XX 2. WIRE LENGTH WIRE LENGTH 0 No lead wire (use only with "KJ" & "KM" elecrical connectors) A 8" B 24" C 6" D 48" E 72" F 96" G 20" H 44". MANUAL OPERATOR G-XX X-X XX BA BB BC BD BE BF BG BH *BN *BP *BR *BS BT BU BV BW *BX *BY ELECTRICAL CONNECTION Flying leads BA with ground wire BA with light parallel to leads BA with light parallel to leads & ground wire BA with suppression diode BA with suppression diode & ground wire BA with suppression diode plus light parallel to leads BA with suppression diode plus light parallel to leads & ground wire BA with suppression diode plus blocking diode BA with suppression diode plus blocking diode & ground wire BA with suppression diode plus blocking diode & light parallel to leads BA with suppression diode plus blocking diode & light parallel to leads & ground wire BA with light on top BA with light on top & ground wire BA with suppression diode plus light on top BA with suppression diode plus light on top & ground wire BA with suppression diode plus blocking diode & light on top BA with suppression diode plus blocking diode & light on top & ground wire G-XX X-X XX MANUAL OPERATOR Non-locking recessed Non-locking extended 4 Locking extended G-XX X-X XX GA GB GC GD GE GF GG GH KA KB KE KF KJ KM *KN *KP KT KU KV KW *KX *KY SOLENOID PLUG-IN CONNECTOR WITH LEADS MAC JAC Solenoid plug-in MAC JAC Solenoid plug-in w/diode MAC JAC Solenoid plug-in w/mov MAC JAC Solenoid plug-in w/led MAC JAC Solenoid plug-in w/diode & LED MAC JAC Solenoid plug-in w/mov & LED MAC JAC Solenoid plug-in w/rectifier MAC JAC Solenoid plug-in w/rectifier & LED Plug-in wire assembly KA with ground wire KA with suppression diode KA with suppression diode & ground wire Plug-in housing without wire assembly ('KA' without wire assembly) Plug-in housing without wire assembly ('KB' without wire assembly) KA with suppression diode plus blocking diode KA with suppression diode plus blocking diode & ground wire KA with light on top KA with light on top & ground wire KA with suppression diode plus light on top Note: Blocking diode is located in the lead wire KA with suppression diode plus light & ground wire KA with suppression diode plus blocking diode & light on top KA with suppression diode plus blocking diode & light on top & ground wire 4 Consult Precautions page 27 before use, installation or service of MAC Valves..