Biogas safety control equipment

Similar documents
Engineered Solutions For Your Tank Equipment Needs

Tank Fittings, Flame Arresters, Valves, Gauges, & Accessories

Specifications. Cover Equipment. Shand & Jurs Cover Position Indicator and MCG 2000MAX 4-20 Transmitter

97311T. Features T Enclosed Burner with Touch Screen Control Panel. No visible flame. Touch Screen Control Panel

Features Enclosed Burner. Enclosed Burner. No visible flame. Controlled Combustion environment with natural draft design

VAREC 5910B AND 5920B SERIES RELIEF VALVE WITH FLAME ARRESTER

VAREC 5810B AND 5820B SERIES RELIEF VALVE WITH FLAME ARRESTER

COVER EQUIPMENT. VAREC BIOGAS 400W Series EMERGENCY RELIEF MANHOLE COVERS

SECTION Pressure & Temperature Control

Mercy Hospital of Buffalo Catholic Health System 2 nd Floor Patient Holding Center 3 rd Floor Locker Rooms Shaflucas Architects, PC Project No.

Crispin Valves Operating Guide. Crispin

SEASONAL MAINTENANCE CHECKLISTS Johnson Controls

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

FRP VENTS. Fiberglass Reinforced Plastic Vents... No Exposed Metal Components. Distributed by Relevant Solutions relevantsolutions.

94407 Horizontal Inline Deflagration Flame Arrester

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

SECTION H3 TRAYMASTER SERIES DEAERATORS

Table of Contents. Introduction. Description. Greater Total System Efficiency. Improved Design. Easy Installation and Maintenance

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

VAREC 5810B/5820B Series. Relief Valve and Flame Arrester

ONYX VALVE CO MODEL DAO-PFO Installation & Maintenance

earth safe Fuel Systems for Critical Power

Locktite Manual Reset Gas Shut-Off Valves

627 Series Pressure Reducing Regulators

IMMERSION FIRED HOT WATER BOILER

A. This Section includes natural gas piping, specialties, and accessories within the building.

ONYX VALVE CO MODEL DAO-PFC Installation & Maintenance

Switches for Pressure to 8000 psig, Vacuum, Differential, or Level Control with General Purpose, Watertight or Explosion-Proof Enclosures

SECTION 2.05 FUEL SYSTEM DESCRIPTION FUEL SYSTEM COMPONENTS

COMBINATION PRESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVES 2.01 COMBINATION RESSURE REDUCING AND SOLENOID SHUTOFF CONTROL VALVE

Model Model Model

ONYX VALVE CO MODEL DAO-ADA Installation & Maintenance

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

627 Series Pressure Reducing Regulators

94406 Vertical Inline Deflagration Flame Arrester. Features

PRESSURE RELIEF / SURGE ANTICIPATOR CONTROL VALVE

SECTION PIPING SPECIALTIES PART 1 GENERAL 1.1 SUMMARY

13900 Series. Consolidated * Valves. Pilot-Operated Safety Relief Valve

ONYX VALVE CO MODEL CAR, CAP-PFO Installation & Maintenance

BULLETIN August 2009 PERMASEAL PLUG VALVE. ISO 9001:2008 Certified QMS. SMG Valves A Unit of Southern Manufacturing Group, Inc.

Flame arresters 4301A/4319A ATEX Approved

North American 1599 Electro-Hydraulic Gas Shutoff Valve Bulletin 1599

627 Series Pressure Reducing Regulators

Propane Conversion Systems. Installation Instructions: 2S-LIFAN200TM 2S-LIFAN200FM 2S-LIFAN390TM 2S-LIFAN390FM

Horizontal Pre-Piped Bladder Tanks with Proportioner

SAMPLE SPECIFICATIONS

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

A. Provide all HVAC specialties required to complete the installation of all HVAC systems. B. Manufacturers: Refer to individual product item.

Vertical Pre-Piped Bladder Tanks with Proportioner

BIRKETT SAFESET SERIES PILOT OPERATED SAFETY RELIEF VALVES

The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor

SECTION H4 BOILERMATE DEAERATORS

Electronic Control Valves

Model MTB-ASME Vertical Pre-Piped Bladder Tanks

PRESSURE RELIEF / SUSTAINING CONTROL VALVES

DELUGE VALVE DATA SHEET

LACT MEASUREMENT. Total Head = Or PSI = S.G. 2.31

LANDFILL GAS ELEVATED (CANDLESTICK) FLARE SYSTEM

Gauges, Sight Glasses and Vacuum Breakers

Iron Horse ED Series Pressure Regulator

cs200 series commercial / Industrial pressure reducing regulators

Valve Selection. 1. Function and service considerations

Model MTB-ASME Horizontal Pre-Piped Bladder Tanks

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Section R Foam Systems

Section R Foam Systems

SOLENOID CONTROL VALVE

SECTION 4 - FUEL SYSTEMS AND CARBURETION

Crosby Style JQ Pressure Relief Device. Flow Control

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

RAYPAK ILLUSTRATED PARTS LIST

Crosby Style JQ pressure relief device

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

KEY PORT VALVE SERIES 400 ECCENTRIC VALVES Compact Size. Light Weight. UL Listed. AGA and CGA Approved. Bulletin

DESIGN, OPERATION & MAINTENANCE OF L.A.C.T. UNITS

Direct-Operated Pressure & Temperature Regulating Valves

A. This Section includes general duty valves common to several HVAC piping systems.

PRESSURE REDUCING VALVE

Heating and Gas Installations - December 2014

Cash Valve B SERIES PRESSURE REGULATORS. ISSUED - JANUARY 1999 CAVMC-0509-US-0208 ISO 9001 Certified

AVIATION FUELING CONTROL VALVES

SECTION VALVES PART 1 -GENERAL

B21 Series BASOTROL Gas Valve

P239-1 Supply Pumper Instructions

Crosby Style JQ pressure relief device

Series 105 Simplex Strainer Cast Iron Swing Bolt O-Ring Closure, Flanged Connection Class 125 ANSI Flat Face Flange Rating VENT 'A' FLOW

VIFB Coil Technical Guide

PRESSURE REDUCING CONTROL VALVE

Steam/Water Washdown Units Safety and Operation Installation and Maintenance Instructions

W91/W94 Series TEMPERATURE REGULATORS. Self-Operated Temperature Regulators. Design & Operation W91 Non-Indicating W94 Dial Thermometer

SECTION (15110) - GENERAL DUTY VALVES FOR PLUMBING PIPING

SKP Series SKP25 U.. Pressure Regulating Gas Valve Actuator with Safety Shut-off Function

CASH VALVE SERIES FR BACK PRESSURE VALVES

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

TYPE PC Propeller Condensate Pumps

SPRING LOADED VENTS. Set Points of 3 PSIG and Above PROTECTOSEAL

Combi2 TTW Models (CSW2TW, CDW2TW)

Code Requirements for ASTs at Motor Vehicle-Dispensing Stations

ATi Max Series. Pressure Independent Control Valves 2 Way 2-1/2-6

Transcription:

Biogas safety control equipment As environmental concerns and energy efficiency are increasing, efficient economical and safe gas control systems become an increasingly important part of operating the modern disposal plant. A properly designed digester gas control system can virtually eliminate the release of odors and VOCs, while safely handling the flammable and possibly explosive gases generated by the digester. Shand & Jurs Equipment can pay for itself by converting your digester gases from a liability to an asset. After dropping out sediment and condensate the cleaned gases can be used to supplement plant service gas to run boilers, heaters and other natural gas operated devices. The plant realizes huge savings by essentially powering themselves. In some cases, the excess energy can be sold and the plant can make additional profit. With nearly 90 years of field proven experience in vapor control, Shand & Jurs can provide you the control that you need, with the equipment that is specifically designed to be corrosion resistant to sewage gases. Typical digester gas system

Expanda-Seal TM To reduce emissions, Shand & Jurs designed and patented a high performance valve sealing technology called Expanda-Seal, which has reduced tank emissions and odors in every process environment imaginable. This innovative design actually uses the internal vessel pressure to create a tighter seal the closer the pressure gets to the set point. The end result is a nearly bubble-tight seal. When pressure inside the tank is below the set point, the deflated diaphragm rests on the seat ring in a typical manner, as with any normal valve, retaining internal pressure. As the pressure approaches the set point, the gasket inflates and wraps around the mating seat to achieve this unique sealing effect. When the pressure in the tank is at or above set point, the valve lifts to relieve the overpressure. Digester cover equipments Vertical flame arrester. Model: 94306/94406* Serves as a barrier between external flame and internal vapors Protects digesters containing flammable gases Easy inspection and maintenance due to simple removal of tube bank FM and ATEX* approved Horizontal flame arrester. Model: 94307/94407* Optional sensor ports available Inhibits flame propagation in gas piping systems Protects digesters containing flammable gases Offset design prevents condensate from accumulating Easy inspection and maintenance due to simple removal of tube bank ATEX* approved

3-way safety selector valve. Model: 97190 Sizes: 2, 3, 4, 6, 8 and 10 Permits switchover function High flow capacity with minimal pressure drop Positive shutoff of isolated branch Low torque operation during switchover Provided with red position and lockout position Pressure/vacuum relief vent. Model: 94020 Open or closed options available Pallet reaction lip for smooth lift and reseating Vertical lift pallets assure reliable operation and maximum flow All weather option Innovative Expanda Seal TM CE and ATEX approved Flame arrester (plate element). Model: 94309 Easy to access element/frame Clean and inspect in place Vertical or horizontal configuration FM approved Combination conservation vent and flame arrester. Model: 97570/97571 Serves as a barrier between external flame and internal gases Provides protection against flame propagation Open or closed vent configurations Model 97571: Available with 94309 flame arrester

Cover position indicator. Model 92021 Standard aluminium materials Other materials available Gauges for floating cover Optional switches for alarm Optional transmitter for remote monitoring Emergency vent & manhole cover. Model: 94210 Sizes: 10, 16, 20, 30 and 36 Materials of construction include aluminium, steel and stainless steel 316 Easy installation and handling for inspection Designed to fit 150Lbs ANSI flange (other flanges available) CE and ATEX approved Gauge hatch. Model: 95021 Sizes: 4, 6, 8, 10 and 12 Standard aluminium, steel, stainless steel 316 and bronze Easy access Teflon diaphragm ensures safe tight seal Quick-clamp option allows for hands-free operation CE and ATEX approved View port. Model: 97186 Stainless steel construction Easy visual inspection of tank contents High strength glass window Corrosion resistant construction Gas tight Integrated cleaning system Maximum working pressure of 1 psig

Transmitter MCG 2000 MAX Magnetic Absolute Xmitter Ultra low power Couples to most mechanical gauges Easy maintenance and calibration Lightning and surge protection Not affected by power loss Wireless option available UL-listed and ATEX approved Emergency pressure & vacuum vent/manhole cover. Model: 94225 Sizes: 16, 18, 20 and 24 Materials of construction include aluminium, steel and stainless steel 316 Design incorporates pressure and adjustable vacuum relief Hinged cover provides precise sealing and safety No unbolting of vent for seal replacement or tank examination Clamping manhole cover. Model: 95210 Sizes: 12, 16, 18, 20, 24, 30, 36 and 48 Materials of construction include aluminium, steel and stainless steel 316 Steel, stainless steel, brass or bronze clamps Easy access to tanks for maintenance and inspection Threaded clamping handle provides gas-tight and watertight seal CE and ATEX approved Manual drip trap. Model: 97100 Inlet size: 1 Capacities: 2,7 liters y 5,4 liters Aluminium construction Positive gas shut-off while draining Can be operated manually or remotely with an electronic timer Lever sensor option 5 psi Standard, higher pressure available

Digester gas stream equipment Electric actuated drip trap. Model: 97100A Inlet size: 1 Capacities: 2,7 liters y 5,4 liters Aluminium construction Positive gas shut-off while training Can be operated manually or remotely with an electronic timer Level sensor option 5 psi standard (higher pressure available) Automatic drip trap. Model: 97110 Inlet size: 1 Capacities: 1,8 liters Aluminium construction Positive gas shut-off while training Automatic unattended removal of condensate 5 psi standard (higher pressure available) Flame trap assembly. Model: 97140/97141 Materials: Aluminium and stainless steel 316 Positive emergency shutoff Inhibits flame propagation 255 ºF (124 ºC) fusible link Horizontal or vertical mounting option Combines 97130 thermal valve with 94307 or 94309 flame arrester Foam separator. Model: 97180 Materials: steel and stainless steel Continuous wash spray system Removes foam and particles Large reservoir with baffle Optional: all stainless steel construction Optional: visual drain flow indicator Optional: alarms for high and low water level Optional: water solenoid valves

High pressure manual drip trap. Model: 97101 Inlet size: 1 Capacity: 3,6 liters Positive gas shut-off while draining Locking lever 100 psi standard Sediment trap. Model: 97120 Inlet sizes: 2, 3, 4, 6, 8, 10 and 12 Materials: steel and stainless steel Removes sediment and condensate Large capacity Easy cleanout Low pressure drop design Optional: sight glass and cooling coil available Double port pressure regulator. Model: 97177 Sizes: 2, 3, 4, 6 and 8 Materials: aluminium, carbon steel or cast iron Upstream or downstream control Balanced double port/plug design Large diaphragm for increased sensitivity Externally adjustable set point with visual indicator Fewer moving parts for longer service life No external power source required Well-type manometer. Model: 97400 Sizes: 12, 20, 24 and 30 Materials: aluminium or stainless steel Pressure or vacuum measurement Measures differential or point pressure readings Indoor or outdoor use Easily bank mounted Optional: float check, valves, vented petcock and isolation valves available

Waste gas burners and accessories Flame check. Model: 97200 Sizes: ¼, ½, ¾, 1, 1 ½ and 2 Materials: standard aluminium or stainless steel Prevents flame flashback in pilot or small gas lines High flow capacity 25 psig working pressure Pressure relief and flame trap assembly. Model: 97160/97161 Internal sense tap (external sense tap optional) Positive emergency shut-off Maintain upstream pressure 255 ºF (124 ºC) fusible link Solenoid shut-off option for flare systems Combines 97150 pressure regulator with 94307 or 94309 flame arrester Waste gas burner. Modelo: 97300 High performance stoichiometric pilot No flame front burn-out of pilot gas during ignition Burns high flow, low BTU wet methane Venturi option available Minimizes pilot pipe freeze potential State of the art digital control Fully automated continuous or intermittent pilot Provides alarm outputs

Back pressure check valve. Model: 97220 Eliminates reverse flow Replaceable pallet/seat Maximum flow with minimum pressure drop Flanged or threaded connections Emergency relief vent. Model: 94160 (other materials available) Maximum flow capacity, minimum leakage Reduced number of components Minimized maintenance and replacement costs All-weather option CE and ATEX approved Enclosed flare. Model: 97310 No visible flame Controlled combustion environment including natural draft design High destruction removal efficiency Meets emission standards of EPA and local regulations High turn down ratios Convenient sampling ports Operates with low input pressures Advanced automatic ignition system

Insulation jackets Insulation jackets provide heat retention for equipment in cold weather environments which can affect equipment operation and safety. In extreme cold weather, condensation vapors can cause freezing and plugging of flame arrester elements, valve components and diaphragm housings. Construction of the insulating jacket is silicone impregnated woven glass cloth lining with 1 thick fiber glass material. The jacket is easy to install and remove in the field and should be removed during warm months. Pressure and vacuum relief valve (open). Model 94020. Flame arrester Model 94309 Pressure relief and flame trap assembly. Model 97161.