EZ-LIGHT K30L and K50L Intrinsically Safe Indicators

Similar documents
EZ-LIGHT 2-Color Indicators for Use with Sensors

EZ-LIGHT Indicators 4-Color, Multi-Function

WLA General Purpose LED Light - PWM Dimmable

WLS28-2 LED Strip Light

WLS28 Work Light Strip

WLS28-2 LED Strip Light

WLS28-2 LED Strip Light

WLS28 Work Light Strip

WL50-2 LED Work Light

WL50-2 LED Work Light

TL30 Basic Tower Light

EZ-LIGHT Indicators 5-Color, Multi-Function

Hinge Wing Safety Interlock Switches

Hinge Wing Safety Interlock Switches

LIMIT SWITCH Hawkeye - HX Magnetic Solid State Proximity Sensors Installation, Maintenance and Operating Instructions (HX )

EZ-LIGHT Indicators 4-Color, Multi-Function

EZ-LIGHT Indicators Audible

CL50 Column Light Features

EG Series Installation Manual

WL50S High-Intensity Work Spot Light

USER s MANUAL 1. GENERAL INFORMATION 2. PRODUCT IDENTIFICATION

WARNING! READ BEFORE INSTALLATION

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

Ex Instruction manual. Rotamass Coriolis mass flow meter. IM 01U10X03-00EN-R, 1st edition, Rev FM-1

MODEL K WIRE INDICATING PRESSURE TRANSMITTER INTRINSICALLY SAFE VERSION OPERATION AND INSTRUCTION MANUAL

Instruction Manual October milltronics MD-36 SPEED SENSOR

Category II 1 G only applies to the Constructional Variants shown in table 15.2 of annex 1.

Low Flow Transmitter EJX115A and EJA115E

Intrinsically safe solenoid valves on/off controls - ATEX or IECEX certification

RAE PowerPak User s Guide

Product Specification A1000i Loop Powered/4-20mA Submersible Level Transmitter/Transducer

Type 4-20mA Absolute Shaft Encoder & Optional Dragon Flow Sensor DLS-00X User Manual. hohner OPTICAL ENCODERS

m WARNING! READ m BEFORE INSTALLATION

PT-500 Analog Output Series User Manual

0745A Load Cell. Global Usage Fully Approved for Accuracy and Safety. 0745A Beam Load Cell Fully Approved

Optic Level Switch LO10 Series Owner s Manual

Intrinsically safe pressure relief valves pilot operated, subplate or in line mounting - ATEX or IECEx certification

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

BMRX Series ROTARY LEVEL CONTROL

A Member of the. Integrated Metering Technologies

Instructions-Installation 3A4409C EN. See page 3 for model part numbers and approvals information.

User Guide. RAE PowerPak

Clarius EP PLUS LED FLOODLIGHT Installation Guide

M-100X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

J 6 Se r i e s. Pressure and Vacuum switches. features

M-200X. Explosion Proof Adjustable Flow Switch with Right Angle Flow. Key Features. Description. Operating Principle. Applications

EStrong-series Emergency Stop

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

INSTRUCTION MANUAL (ATEX / IECEx)

RVP-R- VAV controller. In explosion-proof version

Operating Instructions

707Ex. Users Manual. ma Calibrator

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

T95 Load Cell Assembly for Silo, Tank & Vessel Weighing and Axle Weighing

Installation, Operation and Maintenance Instructions Output Range Part Number Input psi bar Impedance Output Range

INSTALLATION, CALIBRATION & TROUBLESHOOTING MANUAL

INSTALLATION/OWNER'S MANUAL DP " Woofer in Enclosure

Installation and Operation Instructions Safety Director Arrow

TRaC Global Limited, Unit 1, Pendle Place, Skelmersdale, West Lancashire, WN8 9PN, United Kingdom

Proportional pressure reducing valves type DHRZO and DHRZA standard and ex-proof version, direct operated, ISO 4401 size 06

Ex m Solenoid Operator Type 0519

M-60X. Explosion Proof Flowswitch with In-line Flow. Description. Key Features. Operating Principle. Applications. Custom Version Available

NEO-DYN MODEL 100P ENCLOSURE 7 ADJUSTABLE EXPLOSION-PROOF PRESSURE SWITCH

Fisher i2p 100 Electro Pneumatic Transducer

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

The filling level sensors are designed in accordance to the following standards

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Rosemount Product Data Sheet , Rev GA Catalog FIELDBUS PROTOCOL. Hazardous Locations Certifications

ENGLISH. A Member of the

20A Solar Charge Controller

YFC. Limit switch. Ex d. 24 operating head types

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

INSTRUCTION MANUAL (ATEX / IECEx)

24V Supply Operation & Specifications Manual. Field Tools. General Description

Do not install and/or operate this safety product unless you have read and understand the safety information contained in this manual.

Holville I.S. Uninterruptible Power Supply Unit (UPS)

GuaRdboX - Gd series IOM (Installation, Operation & Maintenance Manual) 0100-ENG rev.4

GRD Electronic earthing system. Ex d. Polyester coating RAL7035. LED indicators

EMISSION CONTROL WARRANTY STATEMENT

IECEx Certificate of Conformity

WIRING DIAGRAMS FOR BRIDGE CONTROL PANELS

AUTOMATION. Operator s Manual. RPM Series Float Level Sensors. Rev. E, 08/16 Doc Automation Products Group, Inc.

LABOR ASTER INDUSTRIAL AUTOMATION. Intrinsically safe barrier with separation FIELDBUS TRANSMISSION LINES CONVERTER-SEPARATOR

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

User s Manual Model EJA110A, EJA120A and EJA130A Differential Pressure Transmitters

HR-20P Pneumatically Controlled Pressure Regulator

User s Manual. Item no. 2561

10 S e r i e s PRESSURE SWITCH. features

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

Fisher 646 Electro Pneumatic Transducer

Woolich Racing. Bike Harness Installation Instructions Hayabusa Gen 2 (08+)

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Capacitive Sensors. Series 80 - PNP

Installation and Operating Manual

Linear Luminaire with LED Series EXLUX 6402/2

Instructions and Parts List 3M-Matic P/N Infeed/Exit Conveyor Attachment, 1.2 Meter

ILED Dorado. User Manual

Transcription:

For use in hazardous areas with suitable zener barriers or galvanic isolators ATEX and IECEx certifications Fully sealed and rated to IP67/IP69K 1-, 2-, or 3-color models available; 5 available colors Models Family Color 1 Color 2 Color 3 Input Connection Example: K50L EI G R Y P Q K30L K50L I = EX ia G = Green R = Red Y = Yellow B = Blue W = White X = No color P = PNP Q = 4-pin integral Euro QD 1 Blank = 2 m PVC integral cable W/XX = XX ft cable QP = 4-pin Euro PVC Pigtail QD K30L Models Model Connection 2 LED Function Input K30LIGXXPQP 1 Color: Green K30LIYXXPQP 1 Color: Yellow K30LIRXXPQP 1 Color: Red K30LIBXXPQP 1 Color: Blue K30LIWXXPQP 4-pin Euro PVC Pigtail Quick Disconnect 1 Color: White PNP K30LIGRXPQP 2 Color: Green, Red K30LIGYXPQP 2 Color: Green, Yellow K30LIGYXPQP 2 Color: Red, Yellow K30LIGRYPQP 3 Color: Green, Red, Yellow 1 Only available on K50L models. 2 A model with a QD requires a mating cordset (see Cordsets on page 6). P/N 170955 Rev. A 5/13/2013 0 170955 1

K50L Models Model 3 Connection 4 LED Function Input K50LIGXXPQ 1 Color: Green K50LIYXXPQ 1 Color: Yellow K50LIRXXPQ 1 Color: Red K50LIBXXPQ 1 Color: Blue K50LIWXXPQ 4-pin Euro Quick Disconnect 1 Color: White PNP K50LIGRXPQ 2 Color: Green, Red K50LIGYXPQ 2 Color: Green, Yellow K50LIGYXPQ 2 Color: Red, Yellow K50LIGRYPQ 3 Color: Green, Red, Yellow General Notes 1. The dust rating of enclosures/panels may be invalidated by the installation of the EZ-LIGHT(s). The installation of the EZ-LIGHT(s) in a particular enclosure/panel is subject to the evaluation/acceptance of the applicable approval agency. 2. Installation shall be carried out in accordance with the applicable code of practice by suitable trained personnel. 3. Repair of this equipment shall be carried out in accordance with the applicable code of practice. 4. The X suffix to the certificate number indicates that there is a special condition for safe use, which is that the non-conducting materials of the enclosures may be susceptible to electrostatic charging and precautions must be taken to avoid this. 5. If the equipment is likely to come into contact with aggressive substances 5, then it is the responsibility of the user to take suitable precautions 6 that prevent it from being adversely affected, thus ensuring that the type of protection is not compromised. 6. Clean with a damp cloth only. 7. For indicators with multiple colors, only one color is intended to be on at a time. Specifications Supply Voltage and Current See Configuration on page 4 for safety parameters Indicators Entire translucent diffuser or dome provides indication. LEDs are independently selected: Green, Red, or Yellow; 2 or 3 colors, depending on model. For other colors/ combinations, contact Banner Engineering for availability. Construction Base: polycarbonate Translucent dome: polycarbonate Connections K30: 2 m (6.5 ft) PVC integral cable, or 150 mm (5.9 in) 4-pin Euro PVC Pigtail QD K50: 4-pin Euro integral QD, 2 m (6.5 ft) PVC integral cable, or 150 mm (5.9 in) 4-pin Euro PVC Pigtail QD Environmental Rating IP67/IP69K Operating Conditions 40 C to +50 C ( 40 F to +122 F) or 40 C to +40 C ( 40 F to +104 F), depending on model Certifications Approvals ATEX/IECEx Gas and Vapors: II 1 G Ex ia IIC T4 Ga (Group IIC Zone 0) Dust: II 1 D Ex ia IIIC T130 C Da (Group IIIC Zone 20) Mines: I M1 Ex ia I Ma (Methane) Sira 13ATEX2058X IECEx Sir 13.0020X 3 For 4-pin Euro PVC Pigtail QD Models, replace suffix '"Q" with"qp" in the model number (K50LIGXXPQP). 4 A model with a QD requires a mating cordset (see Cordsets on page 6). 5 Aggressive substances for example, acidic liquids or gases that may attack metals, or solvents that may affect polymeric materials. 6 Suitable precaution for example, regular checks as part of routine inspections or establishing from the materials data sheet that it is resistant to specific chemicals. 2 www.bannerengineering.com - tel: 763-544-3164 P/N 170955 Rev. A

Dimensions K30L Cabled Models K50L Quick Disconnect Models K50L Cabled Models 50.0 mm (1.97") M30 x 1.5 (mounting nut included) Max. Torque 4.5 Nm (40 in-lbf) Internal Threads ½ - 14 NPT Max. Torque 2.25 Nm (20 in-lbf) 38 mm (1.50") 20 mm (0.79") 11 mm (0.43") Hookups C1 C2 C3 3 4 1 2 _ + Wiring Key 1 = Brown 2 = White 3 = Blue 4 = Black Color Key C1 = Color 1 C2 = Color 2 C3 = Color 3 Pinout 2 3 1 4 P/N 170955 Rev. A www.bannerengineering.com - tel: 763-544-3164 3

Configuration Power 8-30V dc Ground Non-Hazardous Location Non-Explosive Atmospheres One Color Configurati on I.S. Barrier #1 Hazardous Location Explosive Atmospheres ATEX IEC Ex Gas Groups IIC,IIB, IIA Gas Groups IIC,IIB, IIA Zone 0 / Category 1 Zone 0 Temperature Class T4 Temperature Class T4 Dust Group IIIC Dust Group IIC Zone 20 / Category 1 Zone 20 Temperature Class T130 C Temperature Class T130 C N/C Black wire (Pin 4) Brown wire (Pin 1) White wire (Pin 2) Blue wire (Pin 3) K30 / K50 N/C Flying Lead or Quick Disconnect Models Ambient Temperature Range -40 C to +50 C _ I.S. Barrier Installation Notes: _ 1. Safety Parameters are as follows: Ui / Vmax = 30V Ii / Imax = 1A Pi / Pmax = 3.4W Ci = 0 Li = 0 2. Choose approved barriers such that the following conditions are met with all barriers combined Ui / Vmax Uo / Voc Ii / Imax Io / Isc Pi / Pmax Po Co / Ca Ci + Ccable Lo /La Li + Lcable 3. Install I.S. barriers in accordance with manufacturers instructions and local codes 4. Suggested I.S. barriers are as follows MTL 7715+ (15V/100Ω) MTL 7715P+ (15V/50 Ω) Turck MZB15PX (15V/50 Ω) II C II B II A C cable 66nF 0.56µF 1.82µF L cable 35µH 140µH 280µH Figure 1. Control Drawing 1-Color Configuration 4 www.bannerengineering.com - tel: 763-544-3164 P/N 170955 Rev. A

Power 8-30V dc Non-Hazardous Location Non-Explosive Atmospheres Two Color Configurati on I.S. Barrier #1 Hazardous Location Explosive Atmospheres ATEX IEC Ex Gas Groups IIC,IIB, IIA Gas Groups IIC,IIB, IIA Zone 0 / Category 1 Zone 0 Temperature Class T4 Temperature Class T4 Dust Group IIIC Dust Group IIC Zone 20 / Category 1 Zone 20 Temperature Class T130 C Temperature Class T130 C Ground I.S. Barrier #2 Black wire (Pin 4) Brown wire (Pin 1) White wire (Pin 2) Blue wire (Pin 3) K30 / K50 N/C Flying Lead or Quick Disconnect Models 1. Safety Parameters are as follows: Ui / Vmax = 30V Ii / Imax = 1A Pi / Pmax = 3.4W Ci = 0 Li = 0 2. Choose approved barriers such that the following conditions are met with all barriers combined Ui / Vmax Uo / Voc Ii / Imax Io / Isc Pi / Pmax Po Co / Ca Ci + Ccable Lo /La Li + Lcable 3. Install I.S. barriers in accordance with manufacturers instructions and local codes Ambient Temperature Range -40 C to +50 C _ I.S. Barrier Installation Notes: _ 4. Suggested I.S. barriers are as follows MTL 7715+ (15V/100Ω) MTL 7715P+ (15V/50 Ω) Turck MZB15PX (15V/50 Ω) II C II B II A C cable 66nF 0.56µF 1.82µF L cable 35µH 140µH 280µH Figure 2. Control Drawing 2-Color Configuration P/N 170955 Rev. A www.bannerengineering.com - tel: 763-544-3164 5

Power 8-30V dc Ground Non-Hazardous Location Non-Explosive Atmospheres Three Color Configurati on I.S. Barrier #1 Hazardous Location Explosive Atmospheres ATEX IEC Ex Gas Groups IIC,IIB, IIA Gas Groups IIC,IIB, IIA Zone 0 / Category 1 Zone 0 Temperature Class T4 Temperature Class T4 Dust Group IIIC Dust Group IIC Zone 20 / Category 1 Zone 20 Temperature Class T130 C Temperature Class T130 C I.S. Barrier #2 Black wire (Pin 4) Brown wire (Pin 1) White wire (Pin 2) Blue wire (Pin 3) K30 / K50 I.S. Barrier #3 Flying lead or Quick Disconnect Models Ambient Temperature Range -40 C to +40 C _ I.S. Barrier Installation Notes: _ 1. Safety Parameters are as follows: Ui / Vmax = 30V Ii / Imax = 1A Pi / Pmax = 2.8W Ci = 0 Li = 0 2. Choose approved barriers such that the following conditions are met with all barriers combined Ui / Vmax Uo / Voc Ii / Imax Io / Isc Pi / Pmax Po Co / Ca Ci + Ccable Lo /La Li + Lcable 3. Install I.S. barriers in accordance with manufacturers instructions and local codes 4. Suggested I.S. barriers are as follows MTL 7715+ (15V/100Ω) MTL 7715P+ (15V/50 Ω) Turck MZB15PX (15V/50 Ω) II C II B II A C cable 66nF 0.56µF 1.82µF L cable 35µH 140µH 280µH Cordsets Figure 3. Control Drawing 3-Color Configuration 4-Pin Threaded M12/Euro-Style Cordsets Model Length Style Dimensions Pinout MQDC-406 MQDC-415 MQDC-430 MQDC-450 1.83 m (6 ft) 4.57 m (15 ft) 9.14 m (30 ft) 15.2 m (50 ft) Straight 44 Typ. M12 x 1 ø 14.5 1 4 2 3 MQDC-406RA MQDC-415RA MQDC-430RA MQDC-450RA 1.83 m (6 ft) 4.57 m (15 ft) 9.14 m (30 ft) 15.2 m (50 ft) Right-Angle 32 Typ. [1.26"] 30 Typ. [1.18"] 1 = Brown 2 = White 3 = Blue 4 = Black M12 x 1 ø 14.5 [0.57"] Banner Engineering Corp Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. 6 www.bannerengineering.com - tel: 763-544-3164 P/N 170955 Rev. A

This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSE- QUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARIS- ING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. www.bannerengineering.com - tel: 763-544-3164