HERSEY 6CM SIZE 2 1/2", 3", 4", 6", 8", 10"

Similar documents
THE DEFENDER 4D-200 SERIES

MADE IN THE USA BACKFLOW PREVENTERS

Backflow Preventers TABLE OF CONTENTS

BACKFLOW PREVENTION CATALOG

4P-300 4V-500 CONTINUOUS PRESSURE THERMOPLASTIC DUAL. PRINCIPLE (U & Z Flow) DUAL CHECK VALVE. PRINCIPLE (Stn.Steel) REDUCED PRESSURE

INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

DCAP Series 40-4 X X - X X X. Dual Check w/ Atmospheric Port Backflow Preventers

MAINTENANCE MANUAL. Covering Models: Series (1/4-10 ) S Series (1/4-1 ) Series (3-10 )

LEAD FREE * PVS-7000 Engineered Flood Protection Valve Station with SentryPlus Alert

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Awide choice of devices

Flood Control Integrated System (FCIS)

Double Check Backflow Preventer 314" to 2"


BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

Maintenance Manual Reduced Pressure Assembly Models 860 & 880V 2 1 /2" 10"

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

Model 133 Models 134 & 135 AURORA 130 SERIES SINGLE STAGE TURBINE TYPE PUMPS

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

A. This Section includes the following domestic water piping specialties:

Backflow Preventers & Accessories

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

Centrifugal End Suction Fire Pumps

MAG- Backflow Preventers. MAG-BEECO Backflow Preventers deliver the highest level of performance, reliability, ease of use and save time and money.

LEAD FREE * LFF113RFP Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology

THIS WARRANTY IS IN LIEU

PRESSURE REDUCING CONTROL VALVE

Colt Series C400, C500

Cash-Flo. Operation & Maintenance Manual. BackFLOW PREVENTERS. A Division of the Reliance Worldwide Corporation

Laboratory Evaluation Report for: Laboratory Faucet Backflow Preventer

AMES 2000 SS/2000 SE. BASIC REPAIR KIT Repair kit contains all check modules and O-rings

Stainless Steel The Next Generation of Backflow

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

AGD AND AGD4A SERIES

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

LEAD FREE * LFF113FP. Wireless Smart Flood Protection Shut Down Valve with SentryPlus Alert Technology. Materials NOTICE NOTICE ES--LFF113FP

Series 990/990RPDA. Reduced Pressure Zone Backflow Preventer. Sizes: 4", 6", 8" (100mm, 150mm, 200mm)

SECTION VALVES

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

Proposition 65 Warning This product contains chemicals known to the State of California to cause cancer or birth defects or other reproductive harm.

See Water Pressure Reducing Valves Catalog (PHBRWPRV) for more detailed information about the products in this section.

CAST STEEL FLANGED GATE, GLOBE, & CHECK VALVES.

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

MODEL 106/206-PG POWER OPERATED GLOBE VALVE Sizes 1/2" to 8" (106-PG) 3" to 10" (206-PG) Installation, Operating and Maintenance Instructions

Series 4600F. HSC Fire Pumps & Packaged Systems

SPECIFICATIONS EFFLUENT/SUMP DUPLEX SYSTEM ZOELLER SUBMERSIBLE DEWATERING OR EFFLUENT PUMPS

Technical Data TYPE A SERIES AIR ADJUSTED PILOT SPENCE ENGINEERING COMPANY, INC. 150 COLDENHAM ROAD, WALDEN, NY SD 4011 OPERATING PRINCIPLE

KENNEDY VALVE KS-RW RESILIENT WEDGE VALVES

September 2012 / M&H C502 / Model 129

w w w. w a t t s. c o m

Series 867 Reduced Pressure Zone Assemblies

PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

BERMAD Irrigation. IR-300 Basic Valve. 300 Series. ??????? Basic Valve

SECTION VALVES PART 1 -GENERAL

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

SECTION GENERAL-DUTY VALVES FOR PLUMBING PIPING

FM 3. FM 3 with Bypass. Materials and Specifications. Fire Service Meter with Bypass Sizes 3, 4, 6, 8, 10. Features

2 ½ 12. Model RP 4A Model RPDA 4A Model RPDA2 4A. Installation, Operation, and Maintenance Manual

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

FIRE PUMPS & PACKAGED

CASH VALVE SERIES FR BACK PRESSURE VALVES

BERMAD Waterworks. Electronic Control Valve. 700 Series. Model Features and Benefits. Major Additional Features

516509_tabs 11/16/10 4:55 AM Page 1 FIRE HYDRANTS

CROSS-CONNECTION CONTROL MANUAL

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

Title of Presentation. Prevention Name of Person, Assistant Director

Model DV-5 Deluge Valve, Diaphragm Style, 1-1/2 thru 8 Inch (DN40 thru DN200), Deluge System Electric Actuation

BACKFLOW PREVENTION CATALOG

TYPE PC Propeller Condensate Pumps

DOUBLE CHECK VALVES SERIES PRODUCT CODES OPERATION MEDIUM HAZARD RATING. 20mm - 50mm FEATURES APPLICATION SPECIFICATION STATEMENT DESCRIPTION

Deep Well Pump Control Valve

SPECIFICATIONS SEWAGE/SUMP DUPLEX SYSTEM ZOELLER COMPANY SUBMERSIBLE SEWAGE OR DEWATERING PUMPS

BEECO FLOW CONTROL

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

BS 5163 Resilient Wedge Gate Valve

CASH VALVE K SERIES BACK PRESSURE VALVES

Series 995/995RPDA. Sizes: 3" - 6" Reduced Pressure Zone Backflow Preventer/ Reduced Pressure Detector Assemblies RP/IS-995/995RPDA

Mark 6127 Series. Pressure Regulators Mark 6127 Series. Pressure Reducing Valves. Valve Features. Operation

Laboratory Evaluation Report for: Backflow Preventer for Beverage Dispensing Equipment

HYDRAULIC CONTROL VALVES

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

A. This Section includes the following domestic water piping specialties:

CHARACTERISTICS ACCESSORIES. High Efficiency Pilot Operated Safety Valves

How to Specify NH-39

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION HVAC&R VALVES

Backflow Prevention Products and Parts

Automatic Control Valves. Providing quality, performance, dependability, and value for water control applications

TECHNICAL DATA 1-1/2 (dn40)

T e n c a n Backflo w Specialties

SECTION PLUMBING PIPING VALVES AND ACCESSORIES PART 1 - GENERAL

Types 1808 and 1808A Pilot-Operated Relief Valves or Backpressure Regulators

Grooved Piping System for Fire Protection Services

Series PAVC Variable Volume, Piston Pumps

A. American National Standards Institute: 1. ANSI Z Relief Valves for Hot Water Supply Systems.

TECHNICAL DATA. Q= C v P S

Transcription:

SIZE 2 1/2", 3", 4", ", 8", 10" HERSEY CM DESCRIPTION This is a reduced pressure assembly. Production began approximately in 1977 and was discontinued in 2004. The bodies are constructed of both bronze and cast iron in the 2 I/2"- " size. Be sure to specify which you have as the repair kits are different. The bronze body assemblies were discontinued in 2001. The 8"-10" body only come in cast iron. From 1977-1993 the cast iron bodies were galvanized coated. From 1991-1992 the HP painted epoxy was available as an option to the galvanized. In 1993 a fused epoxy coating became the standard. For temperatures from 140-180 F there is a hot water repair kit available for the 2 1/2"-". In 1988 the end to end body dimension on the cast iron bodies in sizes 2 1/2" and 4" were changed. The earlier model in the 2 1/2" cast iron body valve was 1/2" shorter than shown in the dimension chart. The 4" cast iron valve was 1" shorter. The repair parts are the same. The internal hardware parts are mostly bronze. The check and relief seats are replaceable on all sizes. A seat removal tool is needed to replace the check seats. The check and relief springs are contained on all sizes when the covers are removed. The RV spring tension has to be released to perform a proper repair. The relief valve sensing line is internal. From 1990-1992 the galvanized cast iron version adopted a plastic sleeve inside the RV sensing line, this was to eliminate rusting that occurred in the cast iron version which could plug up the sensing line. In 1993 the design of the check cover was changed. Before 1993 a gasket was used to seal the check covers to the body. After 1993 an O-ring seal was used on the check covers. BASIC REPAIR KIT Repair kit contains all rubber discs, diaphragm, gaskets, and O-rings. SIZE KIT NO AIR GAP DRAIN 2 1/2" bronze 3550 3358 2 1/2" cast iron 3543 3358 3" cast iron 3350 3358 4" bronze 3443 3358 4" cast iron 3450 3358 " bronze 343 3358 " cast iron 350 3358 8" 3850 3858 10" 3950 3858 IMPORTANT FEATURES 2 1/2 "-" bronze body unit option -2 1/2 "-lo" galvanized cast iron body -All springs are contained -All seats are replaceable -RVsensing line is internal -Factory repair information enclosed 2-10

FEATURES Exclusive Aergap system protection. Hot-dipped galvanized, epoxycoated cast iron, or bronze body.* Replaceable seats and springs. Rugged one piece body construction for long, dependable service. Can be specified with OS&Y or NRS gate valves. Model CM Reduced Pressure Backflow Prevention Assembly Sizes 2V "- 3"- 4"- "- 8"- DESCRIPTION The Hersey Model CM Reduced Pressure Backflow Prevention Assembly features the exclusive Hersey Aergap system. This design provides the highest level of protection against backflow. The unit consists of two independent spring loaded poppet-type check valve assemblies, and a relief valve, all mounted in a common body. The relief valve is a diaphragm actuated, spring loaded, double seated valve assembly. Two gate valves (either NRS or OS&Y) and four test cocks for field testing complete the basic features. The valve assemblies are of modular design and easily removed from the top of the device for in-line servicing. APPLICATION For use at cross-connections when the danger from backflow presents a health-hazard. In-line maintenance. Test cocks for in-line field testing. Internal sensing passage. Hot water approval to 140 F. *Bronze available in 21/2"-" only. Approvals by: USC, CSA B4., ASSE 1013, AWWA, FM; IAMPO listed; UL, ULC classified, U.S. Navy, U.S. Army. Classified by ( as to friction loss and body strength OPERATION Normal operation-the independent, spring loaded check valves remain closed until there is a demand for water. The relief valve remains closed because of the differential between the supply pressure and the reduced pressure in the zone between the check valves. Backpressure- In the event pressure increases downstream, tending to reverse direction of flow, both check valves are closed to prevent backflow. If the second check valve is prevented from closing tightly, leakage into the reduced pressure zone increases the zone pressure to within a few pounds of the supply pressure. This causes the relief valve to open, and backflow is discharged. Backsiph0nage- If the supply pressure drops to atmosphere or lower than the reduced pressure zone, the relief valve will open, creating an internal air gap at least twice the diameter of the inlet pipe. This air gap is maintained between the first check valve and the second check valve as all the water in the reiuced pressure zone is released to the atmosphere. 2-11 The Aergap Principle If the supply pressure drops Leakage at second check below atmosphere, the flow into the diaphragm the reduced pressure zone, relief valve to open, draining and relief valve liquid to the discharge. level of the relief valve, \ 1 J/ and creating\ f,?>" ", 1 ".. / intsrnal,.".#".i," The reduced II ili._. Combid pressure the hragm and spring the reliefvalvotoopen, to maintain at let 2 PSI positive differential.

Model CM Reduced Pressure Assembly PERFORMANCE (Performance curves are typical only and not a guarantee of performance) Head Loss -21/2", 3" and 4" 20.1 _... uj m_,t 8 1 I _...--- "- 20 Head Loss -", 8" and 10" 20.=....1 tt..-- " -"" 8400 00 800 1000 00 1400 100 1800 2o 1 8800 1000 1; )0 1400 100 1800 2000 2200 2400 2002800 20 1 " "0" NOTE: 300 400 500 00 7( )0 900 1000 RATE OF FLOW-- U.S. GPM Maximum Allowable Pressure Loss allowed by USC at indicated flow. 88T 00 100 2000 2400 2800 3; )0 300 RATE OF FLOW-- U.S. GPM DIMENSIONS 2/2" 3" 4" A (bronze) 35", 4, A (iron) 3Y2" 40" 471/2" B (bronze)... 20" 24, 28Y2" B (iron) 211/2" 24" 29Y2" C (bronze)1 93/4" 10" C (iron) DNRS) D(OS+Y**) E (bronze & iron)! F (bronze) F(iron) Size of Test Cocks Re ef Va Ve Open ng see descrigtio, n " 8" 10" 2" 751/2" 88" 41" 41" 521" 2" 103/4" " 913/1" 10" 103/4" " 21Y4" 223/8" 1#Z 13,5/8" 15114" 19718" 241/2" 293/4" 173/8" 221h" 25" 323/4" 411" 48V2" i01/8" 101/s" 101/8 101/8" 173/8" 173/8" 41/2" 41/2" 43/4" 3/1" 8" and 10" available in cast iron only *OS+Y gate valve "D" dimension valve open. n II 51/4" 51/t4" 51,/4" 3/1" 83/8 103/1" 1/2" 1/2" 1/2" 34" 3/4" 34" 2" 2" 2" 2" 3" 3" N----T WEIGHTS SIZE (BRONZE) 21" 3" NoValves, Lbs. 130 194 NetWt. Net Wt. W/NRS Valves, Lbs. 258 330 NetWtW/OSYValves;Lbs. 218 30 Gross Wt. No Valves, Lbs. 10 224 GrossWt.W/NRSVaIves, Lbs. 288 30 Gross Wt. W/OS+Y Valves, Lbs. 20 32 SIZE (IRON) 2Y2" 3" NetWLNoVatves, Lbs. 10 20 Net Wt. W/NRS Valves, Lbs. 24 330 NetWt.W/OS+YValves, Lbs. 270 340 Gross Wt. No Valves, Lbs. 190 23 GrossW,/NRS Valves, Lbs. 294 30 GrossW/OS+Y Valves, Lbs. 300 370 250 548 430 788 490 875 280 30 470 870 530 905 4" " 8" 10" 293.5.32 1955 47 874 187 279 490 87 192 29 328 22 1370 2100 52 94 1980 3084 540 9 2030 313 MATERIALS AND SPECIFICATIONS Body hot-dippedgalvanized or epoxy coated cast iron; 2 V# -10" Body bronze; Working parts bronze and stainless steel Springs stainless steel* Diaphragms reinforced elastomer Valve discs silicone rubber Maximum rated working pressure 175 psi Hydrostatic test pressure 350 psi Temperature range 33 o_ 140 F (Available up to 180 *8" and 10" first check springs are carbon steel vinyl-coaed. hlt -SHOWN90 I# OUTOF?===.-, POSITION 2-

RELIEF VALVE HOUSING GASKET@ @ @ UPPERSEAT / X 5/1-18 X " LONG_ UPPER SEAT SCREW SOCKET SCREW () UPPER SEAT GUIDE-- UPPEN STUN LOWER SEAT I) COM PRESSION SPRING UPPER LOWER SEAT() () LOWER STEM () UPPER DAPHRAGM PLATE DIAPHRAGIVI. LOWER DIAPHRAGM PLATE CLAMP NUT.@ LOCKWASHEB @ RELIEF VALVE ASSEMBLY AND HOUSING ASSEMBLY 21h"- MODEL CM SPRING FETAINER NUT ( SFRNG RETAINFJR M./T SPRING RETA NER.( SPRING RETAINER DISC HOLDER D,SC GUIDE CAPSCREW SEAT R,NG 0 SEAT RING SE.T RING MAIN VALVE ASSEMBLY 2Vz"-" MODEL CM 2-13 CHECK VALVE ASSEMBLY 21/2"-" MODEL CM

RELIEF VALVE HOUSING RELIEF VALVE HOUSING RELIEF VALVE( ) HOUSING NUT RELIEF UPPER SEAT CAPSCREW L-) UPPER DISC UPPER SPACER LOWER SIAT@ LOWER DISC () SPRNG () DIAPHRAGM PLATE GASKET UPPER DIAPHRAGM PLATE () () DIN: IRAGM () CLAMP NUT NUT RELIEF VALVE ASSEMBLY AND HOUSING ASSEMBLY 8" & 10" MODEL CM SPRING RETAINER EYE BOLT SPRtNG SPRING DISC HOLDER ) WASHER () GUIDE WASHER MAIN VALVE ASSEMBLY 8" & 10" MO,D,EL CM 2-14 CHECK VALVE ASSEMBLY 8" & 10" MODEL CM

AIR GAP DRAIN FUNNEL For installation with Hersey Model CM 21/2 ", 3", 4", ", 8" and 10" DESCRIPTION: Easily installed air gap fu.nnel to plumb discharge from relief valve vent of CM reduced pressure principle device. Should plumbed drainage system become clogged, backflow will spill out through the fixed air gap between funnel and CM unit. Two bolts allow simple field installation to the standard cast iron relief valve outlet as furnished with the device. The bottom of the air gap drain funnel is threaded to allow easy installation of drainage pipe. The device is constructed of cast iron and is designed in accordance with the National Plumbing code for Drain Funnel Air Gaps. FUNCTION: Provides protection of the Model CM from contamination due to backflow in the drain line when installed beiween the relief valve outlet and the plumbing drainage system. When installed to a CM, the air gap drain funnel will prevent contamination from cross connection between the potable water supply and the fixture that handles the draining of the waste. Weights and Dimensions PART SIZE A B C NUMBER 21/ 3358 81/ 101/4 15" 3" 3358 8W 101/ 15%" 4" 3358 81, 10%" 11 " 3358 81/ 10W 17%" 8" 3858 J41/ 181 28%" 10" 3858 141, 18W 30" D TH R EAD SIZE 2-111/ 2-111/ 4-8 4-8 /GT. LBS. 11V2 11& 2-15