In-Line Fans xial-flow Fans Wall Versions xial-flow Fans Cased Versions Roof Fans Fans TEX Centrifugal Fans VISP/VSP Centrifugal Fans Side Channel lowers Chip Extractors COMPCT 44 TCx, TCTx FC 54 FC-V 5 FC-HT FD 61 Domestic Fans ccessories Electric Diagrams General Information Index FH 63 FS FK ccessories 6 +46 31-3 +46-4 1 43
xial-flow Fan COMPCT cased version Construction Motor with painted cast aluminum casing. Impellers made of injection moulded plastic reinforced with anchored fiberglass, UV stable (TCFT/TCF), or die casted in aluminium (TCT/TC). Dynamic balanced according to ISO 194. djustable impellers in plastic or aluminium can be supplied on request. For duct installation the fan is mounted in a casing of steel sheet. The motor and the unique construction of the impeller give compact solidity and allow wall- and duct-mounting in all variable positions. Motor 3 415V, Hz three-phase alt. 4V, Hz single-phase asynchronous motor, thermal protection with outgoing leads to the TCFT, TCF terminal box. Enclosure IP according to UNE 113 and IEC 34 1 (size /4-7 and are IP55). Insulation class F for a maximum environmental temperature of +7 C. The motor is designed according to IEC 34 1 and is dynamic balanced according to ISO 194. Speed controllable by variation of the supply voltage by means of transformer or electric regulator (not size /4-5, -4-63, 7 and ). Special voltage or frequency, improved enclosure can be supplied on request. Wiring diagram, see page 35. Model numbering system Special version Ex L S = air direction motor - impeller for wall mounting = air direction impeller - motor, standard for duct mounting = explosion proof motor EExe II T3 = weather proof enclosure M = extended lead (3mm long) = motor and impeller only lade angle H = high (approx 34 ) L = low (approx ) Nominal diameter in mm Speed: = approx rpm Hz 4 = approx 1rpm Hz 6 = approx rpm Hz = approx rpm Hz of motor: T = three-phase = single-phase Impeller: F = fixed blades impeller, standard G= adjustable blade impellers = impeller in aluminium C = compact series Fan mounting: H= wall mounted T = case duct mounted ccessories COP page 6 RE page 3 RM, RMT page 3 44 +46 31-3 +46-4 1
+46 31-3 +46-4 1 45 315 355 5 63 7 (6/ p) 37 36 46 47 7 595 5 5 6 9 355 395 5 63 6 77 C 17 17 17 17 4 4 4 D 54 315 355 5 63 7 E N 4 16 Ø Ø Ø 7/L 7/H /L /K /G /H 6 6 96 96 96 96 77 77 C 3 3 3 3 3 3 D 7 7 4p 45 46 419 415 4 4 E 6p - - 39 419 415 415 p - - 39 39 419 419 (4 p) (4 p) Ø Ø -/H -315/G -355/J 4-/H 4-315/H 4-355/H 4-/H 4-/H 4-/H 4-5/L 4-5/H 4-63/L 4-63/H 4-7/L 4-7/H 4-/L 4-/K 4-/G 4-/H 63 5 45 47 61 56 6 1 5 6 63 5 44 37 39 41 41 44 44 46 46 47 56 64 47 59 6 61 61 61 1 3 5 7 56 5 64 7 3 9 94 96 99 5 61 7 4 95 9 99 7 7 3 6 96 9 59 63 7 7 1 3 6 9 94 97 61 6 7 1 3 5 7 4 4 43 55 59 6 64 6 7 7 1 Hz Hz 6-355/H 6-/H 6-/H 6-/H 6-5/L 6-5/H 6-63/L 6-63/H 6-7/L 6-7/H 6-/L 6-/K 6-/G 6-/H -/H -/H -5/H -63/H -7/H -/L -/K -/G -/H 63 5 39 34 3 36 36 3 37 39 45 4 5 61 6 45 46 4 51 51 6 77 46 49 55 59 6 6 59 64 6 7 1 9 91 9 93 64 6 7 9 91 9 94 54 6 6 7 4 5 6 4 56 6 64 77 7 1 37 41 47 54 56 5 64 6 7 63 5 3 41 44 43 4 54 54 55 56 41 43 47 49 6 7 47 59 1 3 4 55 5 5 5 6 7 5 61 64 5 6 6 7 55 5 61 1 47 49 5 37 39 43 63 64 Hz Hz Number of holes Dimensions in mm POLE 4 POLE 6 POLE POLE xial-flow Fan COMPCT cased version coustic characteristics Sound pressure level d()
xial-flow Fan COMPCT cased version Technical specification TCFT / TCF Number of poles Cased version Speed rpm Maximum power W Maximum current 3 V V Sound pressure level d () Duty at free discharge (max) m³/h Weight kg Speed regulation device rticle number TCF/-/H 1, 1 5 1 3 95 TCF/4-/H 133,3 15 5 RE-1 1 3 995 TCF/4-315/H 1,6 54 3 7 RE-1 1 351 51 TCF/4-355/H 5 1, 5 34 RE-,5 1 351 151 4 TCF/4-/H TCF/4-/H 34 4 1,6,3 7 9 13 RE-,5 RE-,5 1 351 51 1 351 351 TCF/4-/H 6 3, 6 9 16 RE-5N 1 351 451 SINGLE-PHSE 6 TCF/4-5/H TCF/4-63/H TCF/6-355/H TCF/6-/H TCF/6-/H TCF/6-/H TCF/6-5/H 7 35 4 1 1 4 4,9 7,6,5,6 1, 1,6,4 56 59 4 17 3 45 77 5 9 13 16 RE-5N RE-1 RE-1 RE-,5 RE-,5 RE-,5 1 351 551 1 351 1 1 3 351 1 3 451 1 3 551 1 3 1 1 3 1 TCF/6-63/H 5,6 7 5 RE-5N 1 3 51 TCF/-/H 13,7 4 3 13 RE-1 1 354 551 TCF/-/H TCF/-5/H 5 6 1 4,9 1,3 49 51 46 59 16 RE-1 RE-,5 1 354 1 1 354 1 TCF/-63/H 55 3 1,7 34 5 RE-,5 1 354 51 TCFT/-/H,9,5 1 5 1 33 995 TCFT/4-/H 133,3, 5 1 349 55 TCFT/4-315/H 1 1,6,3 54 3 7 1 3 51 TCFT/4-355/H,,5 5 34 1 3 151 4 TCFT/4-/H TCFT/4-/H 13 3 1,4 1,7, 1, 7 9 13 1 3 51 1 3 351 TCFT/4-/H 13 6,7 1,6 6 9 16 RMT-3,5 1 3 451 THREE-PHSE 6 TCFT/4-5/H TCFT/4-63/H TCFT/6-355/H TCFT/6-/H TCFT/6-/H TCFT/6-/H 13 14 3 35 4 15 1 1 3,9 5,,5,5,,9,3 3,,3,3,5,5 56 4 17 3 45 5 9 13 16 RMT-3,5 1 3 551 1 3 1 1 351 1 1 351 51 1 3 41 1 3 51 TCFT/6-5/H 4 1,6,9 59 1 3 151 TCFT/6-63/H 4, 1, 5 1 3 51 TCFT/-/H 6 13,7,4 51 3 13 1 3 551 TCFT/-/H TCFT/-5/H 6 1 3,7 1,,4,6 55 46 59 16 1 3 1 1 3 1 TCFT/-63/H 635 3 1,3, 34 5 1 3 51 46 +46 31-3 +46-4 1
xial-flow Fan COMPCT cased version Technical specification TCT / TC Number of poles TC/-/H Speed rpm Maximum power W 4 Maximum current 3 V V 1, Sound pressure level d () Duty at free discharge (max) m³/h Weight kg, Speed regulation device rticle number 1 3 91 SINGLE-PHSE 4 6 TC/4-/H TC/4-315/H TC/4-355/H TC/4-/H TC/4-/H TC/4-/H TC/4-5/L TC/4-5/H TC/4-63/L TC/6-355/H TC/6-/H TC/6-/H TC/6-/H TC/6-5/L TC/6-5/H TC/6-63/L TC/6-63/H TC/6-7/L TC/6-7/H 133 1 5 137 1 1 134 7 93 4 34 6 4 1 1 4 3 4 5 64 1,3,6 1, 1,6,7 3,5 5, 7,7,4,5,6 1, 1,7,4, 3,1 5,4 5,5 6,5 54 5 6 7 5 6 34 347 7 97 117 137 16 34 45 6 7 1 1, 11, 13, 15,5 1, 5, 33, 34,7 4, 13, 15,5,7 4, 33, 33,5 3, 3,5 46, 46, RE-1 RE-1 RE-,5 RE-,5 RE-5 RE-5 RM- RE-1 RE-1 RE-,5 RE-,5 RE-5 RE-5 RE-5 RM- 1 3 997 1 351 1 351 1 1 351 1 351 3 1 351 4 1 351 1 351 5 1 351 1 3 3 1 3 4 1 3 5 1 3 1 1 3 77 1 3 7 1 3 64 1 3 1 3 7 1 3 TC/-/H TC/-/H TC/-5/H TC/-63/H TC/-7/H TCT/-/H 6 595 595 14 1 44 4 4, 1, 1,4,1,4,9,5 47 4 63 3 47,7 4, 33, 3,5 46,, RE-1 RE-,5 RE-,5 RE-,5 1 354 5 1 354 1 1 354 7 1 354 1 3 1 33 991 THREE-PHSE 4 6 TCT/4-/H TCT/4-315/H TCT/4-355/H TCT/4-/H TCT/4-/H TCT/4-/H TCT/4-5/L TCT/4-5/H TCT/4-63/L TCT/4-63/H TCT/4-7/L TCT/4-7/H TCT/4-/L TCT/4-/K TCT/4-/G TCT/4-/H TCT/6-355/H TCT/6-/H TCT/6-/H TCT/6-/H TCT/6-5/L TCT/6-5/H TCT/6-63/L TCT/6-63/H TCT/6-7/L TCT/6-7/H TCT/6-/L TCT/6-/K TCT/6-/G TCT/6-/H 133 1 13 1 134 13 137 133 13 14 1 1 1 14 14 3 7 7 9 9 9 9 9 1 63 1 1 3 3 6 1 7 4 47 6 1 1,3,6, 1,4,7,9 3,9 4,9 5,6 7,1,4 11,1 11, - - -,5,5,9 1, 1,6 1,7, 4,9 5,7 5, 5,7 7,1 9,,7,,3,5, 1,6 1,7,3, 3, 4, 4, 6,4 6,5 9, 11,6 15,,3,3,5,6,9 1, 1,3, 3,3 3, 3,3 4,1 5, 6, 54 5 6 7 4 7 9 5 6 34 347 7 97 117 137 16 1 15 5 9 33 3 43 34 45 6 7 1 1 3 6, 11, 13, 15,5 1, 5, 33, 34,7 39, 4, 46, 54,, 6, 1, 9, 13, 15,5,7 4, 33, 33,5 3, 3,5 46, 46,, 64, 6,, RMT-3,5 RMT-3,5 RMT- RMT-3,5 RMT-3,5 RMT-3,5 RMT- 1 349 56 1 3 1 3 1 1 3 1 3 3 1 3 4 1 3 1 3 5 1 3 1 3 51 1 3 1 3 1 1 3 77 1 3 7 1 3 7 1 3 7 1 351 7 1 351 1 3 1 3 1 1 3 17 1 3 1 1 3 4 1 3 41 1 3 64 1 3 1 3 361 1 3 364 1 3 3 1 3 36 TCT/-/H TCT/-/H TCT/-5/H TCT/-63/H TCT/-7/H TCT/-/L TCT/-/K TCT/-/G TCT/-/H 5 615 595 9 7 14 1 3 54 6 7 1 134, 1, 1, 1,9,1 3,1 4,3 4, 6,,5,6,7 1,1 1, 1,,5, 3,6 47 63 3 47 16 19,7 4, 33, 3,5 46, 54,, 61, 64, RMT-3,5 1 3 5 1 3 1 1 3 7 1 3 1 3 1 1 3 91 1 3 9 1 3 94 1 3 96 +46 31-3 +46-4 1 47
xial-flow Fan COMPCT cased version Performance curves 4 +46 31-3 +46-4 1
xial-flow Fan COMPCT cased version Performance curves +46 31-3 +46-4 1 49
xial-flow Fan COMPCT cased version Performance curves +46 31-3 +46-4 1
xial-flow Fan COMPCT cased version Performance curves +46 31-3 +46-4 1 51
xial-flow Fan TCx, TCTx Construction xial fan in cased version with casing of welded steel sheet and two contrarotating impellers made in die casted aluminium, dynamically balanced according to ISO194. TCx, TCTx Data TCx/4- TCx/4- TCx/4-5 TCx/4-63 Speed rpm 137 1 134 Maximum power absorbed kw 1,4 1,7 3,5 3, Motor Two 3-415V, Hz three-phase alt. two -4V, Hz singlephase asynchronous motor, therminal protection with outgoing leads to the thermal box. Enclosure IP, insulation class F. Size and are speed controlled by means of transformer or electric regulator. Special voltage or frequency, improved enclosure and three-phase motors for Y resp. running can be supplied on request. Wiring diagram, see page 35. Maximum current 5,4 7,3 15, 19, Sound level* d () 7 Maximum duty m³/h 6 9 14 1 Weight kg 4 rticle number 1 355 1 355 1 355 5 1 355 63 TCTx/4- TCTx/4- TCTx/4-5 TCTx/4-63 * - inlet 1 134 13 137 1,5 1, 3, 4, 3,4 3, 5,, coustic characteristic Sound pressure level d() 7 6 9 14 1 4 1 356 1 356 1 356 5 1 356 63 inlet outlet inlet outlet 5 inlet 5 outlet 63 inlet 63 outlet ccessories Working point m³/h 6 5 4 6 5 4 7 7 13 13 17 1 17 1 63 46 46 5 63 5 4 6 59 63 7 51 55 64 5 7 7 7 5 6 1 5 5 7 7 4 5 4 6 5 7 5 3 7 6 6 7 3 1 5 4 5 91 5 4 6 6 1 5 4 3 5 5 7 5 6 6 91 9 9 93 91 5 3 3 7 7 6 7 5 5 91 9 9 94 9 9 93 91 95 94 94 1 1 4 3 3 5 4 4 7 7 7 6 6 9 9 9 77 7 7 7 1 1 1 3 3 4 64 64 64 7 77 Total 7 9 91 9 9 94 9 9 95 93 9 97 95 95 97 95 94 99 9 97 COP page 6 RM, RMT page 3 +46 31-3 +46-4 1
xial-flow Fan TCx, TCTx Performance curves Pe Pa mmh O Dimensions in mm Ø ØC ØD ØE No. of holes N 7 3 595 3 5 5 5 6 5 63 5 6 63 +46 31-3 +46-4 1
xial-flow Fan FC Construction xial fan designed for installation in a ducted system. Casing of rolled and electro-welded steel sheet, powder coated RL5. Impeller in polypropylene. Casing in acid-proof steel or galvanized steel and impellers in fiberglass reinforced polyamide, in die-cast aluminium or steel sheet may be supplied on request. Motor -4/3-4V, Hz (3-4/6-6V over 3kW) three-phase or -4V, Hz single-phase asynchronous motor with squirrel cage rotor, in accordance with IEC and IEC34-1. Insulation class F, enclosure IP55. Special voltage or frequency, improved enclosure IP, explosion proof motor may be supplied on request. Wiring diagram, see page 35. FC MOILE REV Model numbering system F C / - 4-1T T - Three phase Power rate 1.5 kw x = 1 Diameter of the fan in mm 4 6 C - ~ rpm - ~ 1 rpm - ~ 19 rpm - Cased version F - xial fan ccessories Sleeve FC page FC page Sleeve coupling FC page Protection net FC page PER-CN page 6 54 +46 31-3 +46-4 1
xial-flow Fan FC Technical specification Speed rpm Voltage V Motor power kw Maximum current Sound level* d () Maximum duty m³/h Weight kg rticle number FC/--5S FC/-315-37S FC/-355-55S FC/--5T FC/--37T FC/-315-37T FC/-315-T FC/-355-55T FC/-355-1T FC/--1 FC/-- FC/-- FC/-- FC/4-5-1 FC/4-63- FC/4-7- FC/4-- FC/4-- FC/4-P-7 FC/4--1 FC/6--1 FC/6-1-1 FC/--1 * - distance 1 m Dimensions in mm 7 7 144 14 144 144 144 144 144 9 9 3V 3V 3V V V V V V V V V V V V V V V V V V V V V,5,37,55,5,37,37,,55 1,1 1,5, 3, 3, 1,5, 4, 4, 4, 7,5 11, 11, 11, 11, 1,,5 3,4, 1, 1, 1,9 1,35,5 3,4 4,7 6,5 6,5 4,3 4,,1,1,1 14,4 1,,, 5,1 77 77 77 7 1 1 1 3 3 3 3 3 4 5 3 4 3 4 5 9 1 5 3 43 7 15 17 3 15 15 17 3 35 37 5 1 3 3 13 9 13 9 315 13 9 355 13 911 13 911 13 911 315 13 911 317 13 911 355 13 911 356 13 911 13 911 13 911 4 13 911 13 911 5 13 911 63 13 911 7 13 911 13 911 13 911 5 13 911 9 13 911 9 13 911 915 13 911 9 FC/--37 FC/-315-1 FC/-355-1 FC/--1 FC/-- FC/-- FC/4-5-1 FC/4-63- FC/4-7- FC/4-- FC/4-- FC/4-P-7 FC/4--1 FC/6--1 FC/6-1-1 FC/--1 C D E Number of holes 3 3 46 5 6 6 1 13 1 345 395 5 6 6 7 9 9 13 33 3 3 43 47 4 4 7 7 315 355 5 63 7 1 16 16 16 4 4 D C ir direction E ssembly instructions fan protection net sleeve coupling mounting flange sleeve duct +46 31-3 +46-4 1 55
xial-flow Fan FC Performance curves FC/--5 FC/--37 FC/-315-37 FC/-315-3 Pa 1 Pa 1 m³/h m³/h FC/-355-55 FC/-355-1 FC/--1 FC/-45- FC/-- FC/-- Pa Pa m³/h 7 m³/h FC/4-5-1 FC/4-63- FC/4-7- FC/4-- Pa 3 1 Pa m³/h 3 m³/h 56 +46 31-3 +46-4 1
xial-flow Fan FC FC/4-- FC/4-P-7 FC/4--1 FC/6--1 Pa Pa 3 4 m³/h m³/h FC/6-1-1 FC/--1 Pa m³/h +46 31-3 +46-4 1
xial-flow Fan FC - V Construction elt driven axial-flow fan for installation in a ducted system. Casing of powder coated steel sheet, RL5. Impellers in fiberglass reinforced polyamide. Casing in acid-proof steel or galvanized steel and impellers in die-cast aluminium or steel sheet may be supplied on request. Maximum allowed temperature for transported air is - C to C. For performance curves see FC. Motor -4/3-4V, Hz (3-4/6-6V over 3kW) three phase or -4V, Hz single-phase asynchronous motor with squirrel cage rotor, in accordance with IEC and IEC 34-1. Insulation class F, enclosure IP55. Special voltage or frequency, improved enclosure IP, explosion proof motor may be supplied on request. Wiring diagram see page 35. Model numbering system FC-V/4-7- T Three phase motor Power rate x=4kw Fan diameter in mm Motor poles Fan series FC - belt driven ccessories Sleeve FC Stand FC Coupling Protection net page page page page 5 +46 31-3 +46-4 1
xial-flow Fan FC - V Data and dimensions in mm H L For characteristics see FC. Data Voltage Motor Maximum power current L H rticle number V kw FC-V/--1 1,5 3,4 4 4 13917 FC-V/-- 3 6,5 54 1391 FC-V/-- 3 6,5 13917 FC-V/4-5-1 1,5 4,3 13913 FC-V/4-63-, 4, 6 13914 FC-V/4-7- 4,1 6 1391 FC-V/4-- 4,1 7 1391 FC-V/4-- 4,1 13917 FC-V/4--7 7,5 14,4 13917 FC-V/4--1 11 1, 5 4 1391 +46 31-3 +46-4 1 59
xial-flow Fan FC - HT Construction xial fan designed for installation in a ducted system. Casing of steel sheet, powder coated RL74. Made for temperatures up to C continuous running ( C min/h). Impeller in die-cast aluminium. Casing in acid-proof steel or galvanized steel may be supplied on request. For performance curves see FC. Motor -4/3-4V, Hz (3-4/6-6V over 3kW) three-phase or -4V, Hz single-phase asynchronous motor with squirrel cage rotor. Insulation class F, enclosure IP55. Special voltage or frequency, improved enclosure IP, may be supplied on request. Wiring diagram see page 35. Model numbering system FC-HT/4-7- T Three phase Power rate x=4kw Fan diameter in mm Motor poles Fan series FC - high temperature ccessories Sleeve FC Stand FC Coupling Protection net page page page page +46 31-3 +46-4 1
xial-flow Fan FD Construction xial-flow fan in cased version with casing welded of acid-proof steel and reversible impeller in die casted aluminium, dynamically balanced according to ISO194. The fan is suitable for usage in environments with very high humidity. Motor -4/3-4V, Hz (3-4/6-V over 3kW) three-phase or -4V, Hz single-phase asynchronous motor with squirrel cage rotor, in accordance with IEC and IEC34-1. Insulation class H, enclosure IP55. Special voltage or frequency, improved enclosure IP, explosion proof motor may be supplied on request. Wiring diagram, see page 35. C Model numbering system F D / - 6 - T T Three phase Power rate.9 kw x = Diameter of the fan in mm Motor poles D F Reversible version xial fan Data Speed rpm Motor power kw Voltage V Maximum current Maximum duty m/h ³ rticle number FD/4--5T FD/4--37T FD/4--55T FD/4-5-T FD/4--T FD/4--T FD/4--T 1 1 1 1 1 14 14,5,37,55,,, 3,,,9 1,5,4,4 4, 6,5 4, 6,, 11, 13, 17, 6, 13 913 13 913 13 913 13 913 5 13 913 13 913 13 913 Dimensions in mm D E 4 xø 5 4 5 5 5 6 6 1 7 6 1 7 1 9 +46 31-3 +46-4 1 61
xial-flow Fan FD Performance curves Pa 14 5 4 3 m/h Pa 1 3 m/h 6 +46 31-3 +46-4 1
xial-flow Fan FH Construction ifurcated axial fan in tubular version, with motor placed in a chamber, isolated from the air stream. Design allows continuous transportation of gases with max. temp. 1 C. Casing of rolled and electro-welded steel sheet, powder coated. Impeller in die-casted aluminium. Casings in acid-proof steel or galvanized steel and impellers in steel sheet may be supplied on request. Motor -4/3-4V, Hz (3-4/6-V over 3kW) three-phase or -4V, Hz single-phase asynchronous motor with squirrel cage rotor, in accordance with IEC and IEC-34-1. Insulation class F, enclosure IP55. Special voltage or frequency, improved enclosure IP, explosion proof motor may be supplied on request. Wiring diagram, see page 35. Model numbering system F H / - 4-1T Maximum allowed temperature +1 C - continuos running T - Three phase Power rate 1,1 kw x = 1 + C - temporary running Diameter of fan in mm Motor poles H - High temperature version F- xial fan Dimensions in mm C E F H No. of holes FH- 4 4 4 FH- 554 5 64 34 FH- 6 556 FH-63 63 6 34 FH-7 7 3 6 7 77 3 FH- 6 56 7 3 37 FH- 16 56 11 7 5 Technical specification FH/--1 S FH/--1 T FH/4--37 T FH/-- T FH/4-- T FH/4-63-1 T FH/4-7- T FH/6-7-55 T FH/6--1 T FH/6--1 T * - distance 3 m Speed rpm 1 1 1 1 9 9 9 Motor power kw 1, 1,,37 3,, 1, 4,,55 1, 1, Maximum current ( V),, 1,7 6, 1,1,7,3 1,,, Maximum duty m³/h 61 61 3 6 15 14 Sound level * d () 3 3 5 7 1 rticle number 113 9 113 9 113 9 1 113 9 113 9 113 9 113 9 6 113 9 113 9 113 9 +46 31-3 +46-4 1 63
xial-flow Fan FH Performance curves P st Pa FH/--1 FH/4--37 FH/-- P st Pa 3 FH/4-63-1 FH/4-- 4 P st Pa 3 1 4- - 1 4 3 m/h FH/4-7- FH/6-7-55 4-7 - Q 1 P st Pa 1 4-63 4- FH/6--1 FH/6--1 7 Q 3 m/h 6-7 Q Q 3 m/h 3 m/h 64 +46 31-3 +46-4 1
xial-flow Fan FS Construction xial-flow fan with vertical stand, casing in welded steel sheet, fan blades in fiberglass reinforced polypropylene with a hub in aluminium, dynamically balanced according to ISO194, wire guards on the inlet and outlet. The fan is provided with a protection nets and a pre-assembled switch with a speed regulator. The fan can be used as a local cooler, dryer, exhauster or temperature balancer. Motor -4V, Hz single-phase asynchronous motor. Enclosure IP55, class F insulation. Special voltage or frequency, and enclosure may be supplied on request. Wiring diagram, see page 35. Dimensions in mm D L H FS/-3-55S 3 5 FS/--1S 4 4 FS/4-5-1S 4 Data Speed rpm Motor power kw Maximum current Voltage V Maximum Sound Weight pressure flow level m ³ /h d () kg rticle number FS/-3-55S,55 3,4 3 7 4 13 914 5 FS/--1S 1, 7,9 3 6 13 914 54 FS/4-5-1S 1, 7, 3 77 37 13 914 5 +46 31-3 +46-4 1
xial-flow Fan FS Performance curves Pa 3 5 4 6 14 16 1 4 6 m ³ /h +46 31-3 +46-4 1
xial-flow Fan FK Construction xial-flow fan for duct mounting with a casing in welded steel sheet, fan blades in fiberglass reinforced polypropylene with a hub in aluminium, dynamically balanced according to ISO194, wire guards on the inlet and outlet. The fan is provided with a stand and a pre-assembled switch with a speed regulator. The fan can be used as a local cooler, dryer, exhauster or temperature balancer. Motor 4V, Hz single-phase asynchronous motor according to UNE-113 and IEC34-1, with a thermal motor protection type Klixon. Enclosure IP55, class F insulation. Special voltage or frequency, and enclosure may be supplied on request. Wiring diagram, see page 35. Data Speed rpm Voltage V Motor power kw Maximum current Maximum duty m³/s Sound level* d () rticle number FK-315 14 3, 1,,7 61 13 914 315 FK-355 14 3,1 1,4 1 6 13 914 355 FK- 14 3,37, 1,5 13 914 FK- 14 3,55 3, 13 914 FK- 14 3,55 3,,5 13 914 FK-5 14 3,55 3, 3 13 914 5 * - distance 1 m Dimensions in mm F D E F FK-315 43 315 D FK-355 47 355 3 FK- 5 3 FK- 6 E FK- FK-5 6 5 6 +46 31-3 +46-4 1
ccessories PER-W Louvre shutters in plastic PER- W PER-5 W PER-1 W PER- W/N PER- W/N PER- W/N PER-3 W/N PER- W/N PER- W/N PER- W/N 3 15 17 45 99 347 397 4 1 549 15 5 6 6 6 31 31 C 1 13 1 35 3 364 395 445 ØD 9 13 1 3 3 43 4 5 ØE 4 4 4 5 5 5 5 5 5 5 D C PER-5 W/N 6 5 3 PER-6 W/N 6 66 31 D PER-7 W/N 9 7 3 31 PER- W 4 7 4 C PER- W 4 9 4 PER-CN Louvre shutters in aluminium sheet PER- CN PER-355 CN PER- CN PER- CN PER- CN PER-63 CN PER-7 CN PER- CN PER- CN 333 39 451 4 5 1 4 4 4 4 4 C 7 3 45 45 511 5 6 9 COP Flexible flange connector COP- COP-315 COP-355 COP- COP- COP- COP-5 COP-63 COP-7 COP- Ø 33 36 46 47 7 595 5 5 6 96 Max. 36 36 4 9 9 9 Min. 1 1 1 6 6 13 13 13 13 13 ØC 9 355 395 5 6 6 77 ØD 315 355 5 63 7 ØE N -Noof holes 4 16 16 6 +46 31-3 +46-4 1
ccessories Mounting base FC D holes ØE 315 355 5 63 7 315 355 5 63 7 1 15 55 3 4 4 5 6 7 9 C 5 37 35 334 364 445 45 5 7 D 3 3 3 3 E 14 14 14 14 Sleeve FC max min C D E N - No 315 355 5 63 7 315 355 5 63 7 1 35 37 4 495 545 595 5 1 5 95 995 95 35 37 4 495 545 595 5 1 5 95 995 95 Sleeve coupling FC Protection net FC 55 55 55 1 1 1 5 5 5 1 1 1 1 1 1 345 395 5 6 6 7 9 345 395 5 6 6 7 9 315 355 5 63 7 315 355 5 63 7 of holes C D E N - Number of holes Protection nets for inlets and outlets for axial fan FC may be delivered on request. +46 31-3 +46-4 1