Flask shaker SF1. Instructions for use Manuel d'utilisation Istruzioni per l uso Instrucciones de funcionamiento Bedienungsanweisung. Version 2.

Similar documents
Rockers &Shakers Shakers

Orbital Shaker-Incubator ES-80

OPERATOR S MANUAL Please read all the information in this booklet before using the unit.

Instruction Manual. Vortex Mixers

3. Operating instructions: Minor 200

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

Battery Charger JCB- SCH20LI.2

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Operating Instructions

INSTRUCTIONS FOR USE. Operation and Maintenance manual. Light Industrial Compressor. Hi-Tech Diagnostics Service

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

DC POWER SUPPLY ALIMENTATION C.C.

The Powermatic User Guide Test Sieve Shaker

Operating Instructions. International English. CCS Dust Extractor

Fiber Optic Illuminator. Model 21AC Model 21DC

Tail Flick Analgesia Meter Users Manual. Hot Plate Analgesia Meter START STOP HARVARD. Temperature C. Time h.mm.ss HARVARD APPARATUS

Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

HD18F2M1.

Battery Charger JCB-FCH20LI2

Sieve Shaker 200mm/300mm - 8/12 inch SV003

3 PORT MOTORISED VALVE (22 mm)

VT Oil-Free Range Operators Handbook

362 Clamp Meter. Users Manual

AC/DC CURRENT TRANSDUCER INSTRUCTION MANUAL

Bedienungsanleitung Schüttler KM. Operating Instructions Shaker KM. Mode d emploi Agitateur KM KM 2 KM 2 AKKU KM CO 2 VERSION 04 / 2016

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

362 Clamp Meter. Users Manual

MPS14 Rack Mount Power Supply

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

2 PORT MOTORISED VALVE (28 mm)

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

CIRCUIT-TEST OPERATION MANUAL. Switching Mode Power Supply with Remote Sensing PSC V 5A / 0-27V 3A / 0-36V 2.2A (80W)

Declaration of Conformity

Battery Charger JCB-FCH12Li

LED NEUTRON 4 x QUAD COLOUR LED LIGHT EFFECT

Incubators. Incubators

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

3 PORT MOTORISED VALVE (32/38 mm)

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Instruction Manual. Labnet Spectrafuge 16M Microcentrifuge

AC/DC CURRENT TRANSDUCER 600A 10mV/1A, 1mV/1A

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Melting Point Device DMP100 OPERATING MANUAL VERSION 1.11

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

CD500 KG68 KG75 CD500/KG68-75 UK p01-12.pm /12/99, 1:34 pm

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

Meinzer II TM. Testing Sieve Shaker

OPERATING MANUAL. Cole-Parmer Stir-Pak General-Purpose Laboratory Mixer. Model Number General-Purpose Laboratory Mixer System

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

Sivoia QED R Installation Instructions Please Leave for Occupant

Clinispin CT20 User Manual

28W WORK LAMP Model: CTL28 Part No:

NT-500 Technical Support Guide. For use by qualified company approved Technicians

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

PY-11 Voltage & Continuity Tester

Model G14SD Vapor Management System

Light Source User Guide

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

DIGITAL RCD(ELCB) TESTER

MX-S/MX-F Vortex Mixers

Centrifuge. Model XC-1000 Operating Manual


Bibbyjet Pipette Controller. Fingertip control... technology & ergonomics in harmony

Rutland Remote Display -Model Installation and Operation

PL900 ILLUMINATOR. Fiber-Lite. Operation Manual. Setup. Fiber Optic Connection A PRODUCT OF DOLAN-JENNER INDUSTRIES. Voltage Selection:

Operating Manual. Operating Manual HYBRIDIZATION INCUBATOR. combi-h12 combi-d24 combi-v12 combi-sv12 combi-sv120

Cable Length Meter INSTRUCTION MANUAL

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

INSTRUCTION MANUAL DM5B Fax: (503)

Users Manual. Phase Rotation Indicator

Instruction Manual for the Revolutionary Science RS-200 RevSpin Microcentrifuge

LED Twister II. User manual UK Version 1.0

ICA 39T INSTRUCTION MANUAL ICA39T AC/DC CURRENT TRANSDUCER

i3000s/i2000 Flex AC Current Probe

Rental Industry Safety Tester Safe Check 5s

41210S CIRCUIT BREAKER FINDER WITH GFCI Instrucciones de uso Detector de Interruptores con GFCI 41210S. Operating Instructions

12 amp RMS Battery Charger

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

Demco. Model E Bedienungsanleitung Instruction manual Mode d emploi Istruzioni d uso Instrucciones para el servicio Инструкция по эксплуатации

MityFlex Peristaltic Pump

365 Detachable Jaw True-rms Clamp Meter

PRS 9. Installation Instructions Cycling Timer PRS 9. A Siebe Group Product 1

OPERATION INSTRUCTIONS

superstart starter/chargers

TIX402 EOS Installation and Operating Guide

Instruction Manual for the Revolutionary Science RS-102 RevSpin Microcentrifuge

RECHARGEABLE PORTABLE EVAPORATIVE COOLER

PF400 OPERATING MANUAL

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

INSTRUCTIONS FOR USE

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

6 x 10 Belt Disc Sander

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

Car Battery Charger Instructions for Use

373 Clamp Meter. Users Manual

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

Transcription:

flask shaker Flask shaker Instructions for use Manuel d'utilisation Istruzioni per l uso Instrucciones de funcionamiento Bedienungsanweisung Version 2.0

English flask shaker Mains On/Off Indicator light Speed controller Timer Flask shaker Instructions for use Introduction Thank you for purchasing this piece of Stuart equipment. To get the best performance from the equipment and for your own safety, please read these instructions carefully before use. Before discarding the packaging check that all parts are present and correct. This equipment is designed to operate under the following conditions: For indoor use only Use in a well ventilated area Ambient temperature range +5ºC to +40ºC Altitude to 2000m Relative humidity not exceeding 80% Mains supply fluctuation not exceeding 10% Over-voltage category II IEC60364-4-443 Pollution degree 2 If the equipment is not used in the manner described in this manual and with accessories other than those recommended by Stuart, the protection provided may be impaired.

Electrical Installation THIS EQUIPMENT MUST BE EARTHED Before connection please ensure that the line supply corresponds to that shown on the rating plate. Model Supply requirements Power 230V, 50Hz 50W All models are supplied with two mains leads fitted with IEC plugs for connection to the instrument. One has a U.K. 3 pin plug and the other has a 2 pin Shuko plug for connection to the mains. Choose the lead appropriate for your electrical installation and discard the other. Should neither lead be suitable, take the lead with the U.K. plug and replace the plug with a suitable alternative. This involves cutting off the moulded plug, preparing the cable and connecting to the re-wireable plug in accordance with its instructions. THIS OPERATION SHOULD ONLY BE UNDERTAKEN BY A QUALIFIED ELECTRICIAN NOTE: Refer to the equipment s rating plate to ensure that the plug and fusing are suitable for the voltage and wattage stated. The wires in the mains cable are coloured as follows: BROWN - LIVE BLUE - NEUTRAL GREEN/YELLOW - EARTH The instruments are fitted with an IEC socket at the rear of the instrument for connection of the mains lead. The appropriate mains lead should be connected BEFORE connection to the mains supply. Should the mains lead need replacement, a cable of 1mm 2 of harmonised code H05W-F connected to an IEC320 plug should be used. IF IN DOUBT CONSULT A QUALIFIED ELECTRICIAN Safety Advice Before Use The unit should be carried with both hands, with fingers under each side of the frame. Never move or carry the unit while it is in use or connected to the mains supply. There is a danger of liquid spillage and splashing if containers are over-filled and shaken at high speed. Always build the shaking speed up slowly and never shake more rapidly than necessary. Ensure the load is balanced. General Description The flask shaker comprises two side arms each with four clamps capable of holding bottles or flasks up to 500ml capacity. The vigorous mixing action simulates hand shaking and this motion is controllable between 80 and 800 oscillations per minute. The speed is controlled by a soft start feedback controller to avoid splashing on start up and give constant speed, irrespective of load. There is a built-in analogue timer that can be set from 10 to 60 minutes, which automatically turns the unit off once it has counted down. There is also a manual control position for continuous operation. Accessory side arms are available to increase the capacity to twelve bottles or flasks. Controls Refer to Figure 1 to identify the controls. Mains On/Off flask shaker Indicator Light Figure 1: controls. Speed Controller Timer 1

Mains On/Off: This is a rocker-type switch. Presing the top switches the unit on and pressing the bottom switches the unit off. The switch is illuminated when the unit is on. Indicator light: An amber LED illuminates when the unit is in operation. Speed controller: This knob controls the speed of shaking. Turning it to the right switches the motor on and increases the shaking speed. Turning it to the left decreases the shaking speed and switches the motor off. A scale is printed around the knob as a speed guide. Timer: Turning this knob to the right starts the timer. A scale in minutes is printed around the knob as a guide. Turning to the left engages continuous operation. Assembly 1. Fit the shaker arms into the drive shafts and tighten the grub screws with the Allen key provided. 2. Position each clamp into place ensuring they are horizontal and tighten the securing screws. Operation 1. Position the apparatus on a firm, level surface ensuring the shaker arms are free to move. 2. Fit the flasks to be shaken into the jaws of the clamps and tighten the grip. 3. Ensure the speed controller and timer knobs are fully to the left and turn the mains switch ON. The indicator light should be lit. 4. Turn the timer knob to the required shaking time. Then turn the speed controller to the right until the desired shaking speed is observed. Maintenance & Servicing WARNING: Ensure the unit is disconnected from the mains electricity supply before attempting maintenance or servicing. Periodically clean the instrument using a damp cloth and mild detergent solution. Do not use harsh or abrasive cleaning agents. Any repairs or replacement of parts MUST be undertaken by suitably qualified personnel. For a comprehensive list of parts required by service engineers conducting internal repairs, please contact the Service Department, quoting both the model number and serial number: E-mail: service@bibby-scientific.com Tel: +44 (0)1785 810475 Fax: +44 (0)1785 810471 Only spare parts supplied or specified by Stuart or its agents should be used. Fitting of non-approved parts may affect the performance of the safety features designed into the instrument. If in any doubt, please contact the Service Department of Bibby Scientific Ltd. or the point of sale. For any other technical enquiries, please contact the Technical Support Department: E-mail: stuarthelp@bibby-scientific.com Tel: +44 (0)1785 810433. Spares and Accessories Description Spare clamp Accessory side arms x 2 with 4 clamps Allen key Fuse 3.15AL Catalogue Number /1 /2 N10016 EC11(S) 2

Warranty Stuart warrants this equipment to be free from defects in material and workmanship, when used under normal laboratory conditions, for a period of three (3) years. In the event of a justified claim, Stuart will replace any defective component or replace the unit free of charge. This warranty does NOT apply if damage is caused by fire, accident, misuse, neglect, incorrect adjustment or repair, damage caused by installation, adaptation, modification, fitting of non-approved parts or repair by unauthorised personnel. Bibby Scientific Ltd. Beacon Road, Stone, Staffordshire ST15 0SA United Kingdom Tel: +44 (0)1785 812121 Fax: +44 (0)1785 813748 E-mail: equipment@bibby-scientific.com www.stuart-equipment.com Technical Specification Speed range 80-800 oscillations/min Amplitude 1.5mm Maximum load 3kg Dimensions (w x d x h) 780 x 270 x 240mm Net weight 8.3kg Electrical supply 230V, 50Hz, 50W 3

INSPECTION REPORT MODEL ELECTRICAL SAFETY 1. Earth continuity 2. Insulation 3. Flash test FUNCTIONAL 1. Indicators 2. Speed/Timer control 3. Visual acceptance QUALITY CONTROL INSPECTOR Bibby Scientific France SAS ZI du Rocher Vert - BP 79 77793 Nemours Cedex France Tel: +33 1 64 45 13 13 Fax: +33 1 64 45 13 00 e-mail: bsf@bibby-scientific.fr www.bibby-scientific.com Bibby Scientific Italia Srl Via Alcide de Gasperi 56 20077 Riozzo di Cerro al Lambro Milano Italia Tel: +39 (0)2 98230679 Fax: +39 (0)2 98230211 e-mail: marketing@bibby-scientific.it www.bibby-scientific.it Bibby Scientific Ltd Beacon Road Stone Staffordshire ST15 0SA United Kingdom Tel: +44 (0)1785 812121 Fax: +44 (0)1785 810405 e-mail: info@bibby-scientific.com www.bibby-scientific.com Bibby Scientific US Ltd 3 Terri Lane Suite 10 Burlington NJ 08016 USA Tel: 800-225-9243 Fax: 609-589-2571 www.bibby-scientific.com Bibby Scientific (Asia) Ltd Room 607 Yen Sheng Centre 64 Hoi Yuen Road Kwun Tong Kowloon Hong Kong Tel: +852 3583 1581 Fax: +852 3583 1580 e-mail bibby@bibby-scientificasia.com www.bibby-scientificasia.com