Commissioning Manual AC Servo Actuator LynxDrive SIEMENS SIMODRIVE

Similar documents
Engineering Data Harmonic Planetary Gears HPG

Engineering Data AC Servo Motors FFM/FPM/CFM

Engineering Data HFUS-2UH/2SO/2SH Units

Engineering Data HPGP Harmonic Planetary Gears

ICH Linear Motors REACH. Installation Guide

TPM + Bosch Rexroth IndraDrive. Quick Startup Guide D Revision: 02

TPM + Control Techniques UNIDRIVE SP. Quick Startup Guide D Revision: 02

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

SCOPELITE TIMING LIGHT OPERATING MANUAL

FLUDEX - thermal switching equipment. Operating instructions BA en 04/2012. FLENDER couplings

Engineering Data CSG-2A Component Sets

Below, you can see the warning symbols used throughout the manual and their meaning.

INTRODUCTION WARNING SIGNS AND THEIR MEANINGS

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

HOYMILES MICRO-IVERTER MI-250

Technical Documentation

Differential Pressure Transmitter

DYNEO Synchronous motors with permanent magnets-drive Commissioning

SINAMICS DCM. DC Converter. Application SINAMICS DCM as field supply unit. Edition 04-6/2013. SINAMICS drives

1FK7 Synchronous Motors

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Safety Precaution. Notation. Meaning of symbols WARNING CAUTION

SINAMICS. SINAMICS G130 Braking Module / braking resistor. Safety information 1. General. Mechanical installation. Connection 4

SIMODRIVE FT7 Synchronous Motors. Configuration Manual 03/2010 SIMODRIVE

Operation Manual for Mag650 Three-Axis Magnetic Field Sensor

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

Rexroth IndraDyn E. Standard Motors MOT-FC for Frequency Converter Operation. Project planning manual R Edition 03

Siemens Drives & PLCs

Brushless servo motors as replacements for conventional disk armature motors

FL 10 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS. Before operating the pump, please read the Installation Instructions and safety precautions.

Installation, Operating & Maintenance Instructions. All-metal gate valve with compact or extended pneumatic actuator

HV angle valve with single acting pneumatic actuator and closing spring (NC)

FLENDER ARPEX Plate packs with close-fitting bolt connection. ARW-4 Sizes to Assembly instructions An 4239 en 12/2015.

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

362 Clamp Meter. Users Manual

Installation, Operating & Maintenance Instructions. HV gate valve with pneumatic actuator. Series 110 DN mm (I. D.

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

SERVO MOTORS BRUSHLESS SERVO MOTORS ATEX ZONE 2-22 OPERATING INSTRUCTIONS 2016

CU2 Closed Loop Module

Mod: KLD6-12/35XLAS-N

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

ATN3580 Series: Fixed Attenuator Pads

BAH series Use and Maintenance Manual

Rexroth MKE Synchronous Motors for Potentially Explosive Areas according to ATEX and UL/CSA

Installation, Operating & Maintenance Instructions. HV angle valve with pneumatic actuator single acting with closing spring (NC)

Tina 4A Connection block

Welcome to ABB machinery drives training. This training module will introduce you to the ACS850-04, the ABB machinery drive module.

SPARKSCAN1 HIGH VOLTAGE CLAMP OPERATING MANUAL

SDM320D / SDM320A. Single phase din rail meter SDM320D / SDM320A user manual

HANGKAI GROUP HOYMILES MICRO-INVERTER MI-250

GEWAS 181 A. Alarm- and protection device Leak-water detector

DYNEO VARIABLE SPEED DRIVES Unidrive SP variable speed drives LSRPM - PLSRPM permanent magnet synchronous motors

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

MODVAR Low voltage reactive power compensation modules Installation manual

Tina 11A Connection block

OPERATING MANUAL. Robot Gun Mount T2, T4

Operating instructions

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

Operation Manual for Torque Sensors

SERVO MOTORS BRUSHLESS SERVO MOTORS OPERATING INSTRUCTIONS 2016

Installation, Operating & Maintenance Instructions. UHV gate valve with pneumatic actuator. Series 108 DN mm (I. D. 2½ 8 )

Addendum to the Operating Instructions

BEFORE USING THE PRODUCT

High Frequency SineWave Guardian TM

GETTING STARTED GUIDE NI AI, ±10 V, 12 Bit, 500 ks/s Aggregate

Wind Power Inverter WINDY BOY 5000A/6000A

USER MANUAL D637-R/D639-R SERIES DIRECT DRIVE SERVOVALVES WITH INTEGRATED DIGITAL ELECTRONICS AND OPTIONAL FIELD BUS INTERFACE

Sheet n 1 of 20 Doc. n WDMM/02/E MOD. WDMM INSTALLATION, USE AND SERVICE MANUAL. PETROL INSTRUMENTS S.r.l APRILIA (LT) - ITALY

Levante Sistemas de Automatización y Control S.L.

FF 20 DIAPHRAGM PUMP INSTALLATION INSTRUCTIONS

Installation and Operating Manual for Tank and Equipment Cleaning Nozzles Series 5TM

Engineering Data CPL-2A Component Sets

Reviewed: DD Month University Code of Practice for Electrical Safety. PART B - Design and Construction of Electrical Equipment within the University

Digital Pressure Regulator Sentronic PLUS Series 614

Procedure PR D Electrical Permits. Engineering Procedure Electrical Distribution Unit. Version 1.0. Date in Force: 4 November 2015

SPEEDRIVE INSTRUCTIONS MANUAL

PAS Series AC Servo Motor. Datasheet

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

LV Capacitor CLMD03 Power Module Instruction manual

Swing Piston Compressors and Vacuum Pumps

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Installation Instructions. Y-Series Brushless Servo Motor

BT403. A Geno Technology, Inc. (USA) brand name. BT-300 Power Supply. Cat. No. BT

1ZSE en, Rev. 4. On-load tap-changers, type UC User s manual

Planning and Commissioning Guideline for NORD IE4 Motors with NORD Frequency Inverters

Operating Manual (Edition 04/2004) sinamics. Braking Module / Braking Resistor SINAMICS G130

Rexroth 1 MB Frameless Spindle Motors

SIMOTICS M-1FE2 synchronous builtin. motors for SINAMICS S120 SIMOTICS. SIMOTICS M-1FE2 synchronous built-in motors for SINAMICS S120.

Temposonics Magnetostrictive Linear Position Sensors. Temposonics GB-Series Brief Instructions

INTERNATIONAL STANDARD

I. Safety precautions

Extended Battery Cabinet for Nfinity

Sense7-series Non-contact coded safety switch

USERS MANUAL MCD REMOTE OPERATOR

PV Inverter SUNNY MINI CENTRAL 9000TL / 10000TL / 11000TL with Reactive Power Control

80 Series V Digital Multimeter Safety Information

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

DRIVESPIN ROTARY ACTUATORS

DLT-U1100 UPS Uninterruptible Power Supply Manual V1.00. Industrial PCs applied in

30 top tips to tackle HVAC challenges No.03 - Permanent magnet motors

Transcription:

Commissioning Manual AC Servo Actuator LynxDrive SIEMENS SIMODRIVE 06/2017 1017913

Content 1. General... 3 1.1 Description of Safety Alert s... 4 1.2 Disclaimer and Copyright... 4 2. Safety and Installation Instructions...5 2.1 Hazards...5 2.2 Intended Purpose... 6 2.3 Non Intended Purpose... 6 3. Instructions for Third Party Systems... 7 3.1 General... 7 4. Commissioning... 7 5. Drive Parameter for SIMODRIVE... 8 5.1 LynxDrive-14C-AO-H-MKE... 8 5.2 LynxDrive-17C-AO-H-MKE... 9 5.3 LynxDrive-20C-AO-H-MEE (-MKE / -ROO)... 10 5.4 LynxDrive-25C-AR-H-MEE (-MKE / -ROO)... 11 5.5 LynxDrive-32C-AR-H-MEE (-MKE / -ROO)... 12 5.6 LynxDrive-40C-AT-H-MEE (-MKE / -ROO)... 13 5.7 LynxDrive-50C-AW-H-MEE (-ROO)... 14 2

1. General About this documentation This document contains safety instructions, technical data and operation rules for servo actuators and servo motors of Harmonic Drive AG. The documentation is aimed at planners, project engineers, commissioning engineers and machine manufacturers, offering support during selection and calculation of the servo actuators, servo motors and accessories. Rules for storage Please keep this document for the entire life of the product, up to its disposal. Please hand over the documentation when re-selling the product. Additional documentation For the configuration of drive systems using the products of Harmonic Drive AG, you may require additional documents. Documentation is provided for all products offered by Harmonic Drive AG and can be found on the website. www.harmonicdrive.de Third-party systems Documentation for parts supplied by third party suppliers, associated with Harmonic Drive components, is not included in our standard documentation and should be requested directly from the manufacturers. Before commissioning servo actuators and servo motors from Harmonic Drive AG with servo drives, we advise you to obtain the relevant documents for each device. Your feedback Your experiences are important to us. Please send suggestions and comments about the products and documentation to: Harmonic Drive AG Marketing and Communications Hoenbergstraße 14 65555 Limburg / Lahn E-Mail: info@harmonicdrive.de 3

1.1 Description of Safety Alert s Meaning Indicates an imminent hazardous situation. If this is not avoided, death or serious injury could occur. Indicates a possible hazard. Care should be taken or death or serious injury may result. Indicates a possible hazard. Care should be taken or slight or minor injury may result. Describes a possibly harmful situation. Care should be taken to avoid damage to the system and surroundings. This is not a safety symbol. This symbol indicates important information. Warning of a general hazard. The type of hazard is determined by the specific warning texts. Warning of dangerous electrical voltage and its effects. Beware of hot surfaces. Beware of suspended loads. Precautions when handling electrostatic sensitive components. 1.2 Disclaimer and Copyright The contents, images and graphics contained in this catalogue are protected by copyright. In addition to the copyright, logos, fonts, company and product names can also be protected by brand law or trademark law. The use of texts, extracts or graphics requires the permission of the publisher or rights holder. We have checked the contents of this document. Since errors cannot be ruled out entirely, we do not accept liability for mistakes which may have occurred. Notification of any mistakes or suggestions for improvements will be gratefully received and any necessary corrections will be included in subsequent editions. 4

2. Safety and Installation Instructions Please take note of the information and instructions in this document. Specialy designed models may differ in technical detail. If in doubt, we strong recommend that you contact the manufacturer, giving the type designation and serial number for clarification. 2.1 Hazards Electric servo actuators and motors have dangerous live rotating parts. All work during connection, operation, repair and disposal must be carried out by qualified personnel as described in the standartds EN 50110-1 and IEC 60364! Before starting any work, and especially before opening covers, the actuator must be properly isolated. In addition to the main circuits, the user also has to pay attention to any auxilliary circuits. Observing the five safety rules: Disconnect mains Prevent reconnection Test for absence of harmful voltages Ground and short circuit Cover or close off nearby live parts The measures taken above should only be withdrawn when the work has been completed and the device is fully assembled. Improper handling can cause damage to persons and property. The respective national, local and factory specific regulations must be adhered to. The surface of the gears, motors and actuators can exceed 55 degrees Celsius. The hot surfaces should not be touched. Connection cables must not come into direct contact with hot surfaces. Electric, magnetic and electromagnetic fields are dangerous, in particular for persons with pacemakers, implants or similar. Vulnerable groups must not be in the immediate vicinity of the products themselves. Built-in holding brakes alone are not safety brakes. Particularly with unsupported vertical axes, the functional safety and security can only be achieved with additional, external mechanical brakes. The successful and safe use of gears, motors and servo actuators requires proper transport, storage and assembly as well as correct operation and maintenance. 5

Use suitable lifting equipment to move and lift gears, motors and servo actuators with a weight > 20kg. Special versions of products may differ in the specification from the standard. Further applicable data sheets, catalogues and offers of the special version have to be considered. 2.2 Intended Purpose The Harmonic Drive servo actuators and motors are intended for industrial or commercial applications. They comply with the relevant parts of the harmonised EN 60034 standards series. Typical areas of application are robotics and handling, machine tools, packaging and food machines and similar machines. The servo actuators and motors may only be operated within the operating ranges and environmental conditions shown in the documentation (altitude, degree of protection, range etc.). Before plant and machinery which have Harmonic Drive servo actuators and motors built into them are commissioned, the compliance must be established with the Machinery Directive, Low Voltage Directive and EMC guidelines. Plant and machinery with inverter driven motors must satisfy the protection requirements in the EMC guidelines. It is the responsibility of the installer to ensure that installation is undertaken correctly. Signal and power lines must be shielded. The EMC instructions from the inverter manufacturer must be observed in order that installation meets the EMC regulations. 2.3 Non Intended Purpose The use of servo actuators and motors outside the areas of application mentioned above or, inter alia, other than in the operating areas or environmental conditions described in the documentation is considered as non-intended purpose. Direct operating from the mains supply is not allowed. The following areas of application are, inter alia, those considered as non-intended purpose: Aerospace Areas at risk of explosion Machines specially constructed or used for a nuclear purpose whose breakdown might lead to the emission of radio-activity Vacuum Machines for domestic use Medical equipment which comes into direct contact with the human body Machines or equipment for transporting or lifting people Special devices for use in annual markets or leisure parks 6

3. Instructions for Third Party Systems 3.1 General Please observe the documentation of the SIEMENS AG and the Harmonic Drive AG before putting the system into operation. Quicklink to Engineering Data of the LynxDrive actuator: www.harmonicdrive.de/1040 A detailed description of the electrical connection is given within the "Engineering Data" manual of the selected product. 4. Commissioning Commissioning must be executed in accordance with the documentation of Harmonic Drive AG. Before commissioning, please check that: The actuator is properly mounted, All electrical connections and mechanical connections are designed according to requirements, The protective earth is properly connected, All attachments (brakes, etc.) are operational, Appropriate measures have been taken to prevent contact with moving and live parts, The maximum speed n max is specified and cannot be exceeded, The setup of the drive parameters has been executed, The commutation is adjusted correctly. Check the direction of rotation of the load uncoupled. In the event of changes in the normal operating behaviour, such as increased, noise or vibration, switch the actuator off. Determine the cause of the problem and contact the manufacturer if necessary. Even if the actuator is only on test, do not put safety equipment out of operation. This list may not be complete. Other checks may also be necessary. Due to heat generation from the actuator itself, tests outside the final mounting position should be limited to 5 minutes of continuous running at a motor speed of less than 1000 rpm. These values should not be exceeded in order to avoid thermal damage to the actuator. 7

5. Drive Parameter for SIMODRIVE For the position control, speed control and current control loop of the SIMODRIVE converter system it is necessary to set the drive parameters according to the following tables. 5.1 LynxDrive-14C-AO-H-MKE MD-Name MD-Nr.: [Unit] LynxDrive-14C Ratio 30 50-100 - - Encoder pulse number 1005/31020 n 1 [I/U] 16 Actual value sensing configuration 1011 Factory setting Motorcode 1102 2000 (611D) 1999 (611U) Rated motor current 1103 I N [A rms ] 0,7 0,5 0,4 Maximum motor current 1104 I max [A rms ] 0,9 1,1 0,8 Number of pole pairs 1112 p [ ] 5 Motor torque constant 1113 k TM [Nm/A rms ] 0,39 Motor voltage constant 1114 k EM [V/1000 rpm] 26 Armature resistance (L-N, 20 C) 1115 R L-N [Ω] 3,6 Armature inductance (L-N) 1116 L D [mh] L str. * 1,5 10,5 Moment of inertia 1117 J [kgm²] 0,000025 Motor zero speed current 1118 I 0 [A rms ] 0,7 0,5 0,4 Motor current limit (only611u) 1122 I max [A rms ] 0,9 1,1 0,8 Optimum load angle 1128 [ ] 90 Maximum motor speed 1146 n max [rpm] 8500 Reluctance torque constant 1149 [mh] 0 Lower current limit adaption 1180 [%] 0% Upper current limit adaption 1181 [%] Factor current controller adaption 1182 [%] Rated motor speed 1400 n N [rpm] 3500 Alarm threshold motor over 1602 [ C] 100 Shutdown limit motor 1607 [ C] 120 When using actuators with feedback type MKE, a pole position identification has to be conducted. For details, please refer to the documentation of the drive. 8

5.2 LynxDrive-17C-AO-H-MKE MD-Name MD-Nr.: [Unit] LynxDrive-17C Ratio 30 50-100 - - Encoder pulse number 1005/31020 n 1 [I/U] 16 Actual value sensing configuration 1011 Factory setting Motorcode 1102 2000 (611D) 1999 (611U) Rated motor current 1103 I N [A rms ] 1,2 1,6 1,2 Maximum motor current 1104 I max [A rms ] 1,6 2,0 1,6 Number of pole pairs 1112 p [ ] 5 Motor torque constant 1113 k TM [Nm/A rms ] 0,39 Motor voltage constant 1114 k EM [V/1000 rpm] Armature resistance (L-N, 20 C) 1115 R L-N [Ω] 3,6 Armature inductance (L-N) 1116 L D [mh] L str. * 1,5 Moment of inertia 1117 J [kgm²] 0,000030 Motor zero speed current 1118 I 0 [A rms ] 1,2 1,6 1,2 Motor current limit (only611u) 1122 I max [A rms ] 1,6 2,0 1,6 Optimum load angle 1128 [ ] 90 Maximum motor speed 1146 n max [rpm] 7300 Reluctance torque constant 1149 [mh] 0 Lower current limit adaption 1180 [%] Upper current limit adaption 1181 [%] Factor current controller adaption 1182 [%] 26 10,5 0% Rated motor speed 1400 n N [rpm] 3500 Alarm threshold motor over Shutdown limit motor 1602 [ C] 100 1607 [ C] 120 When using actuators with feedback type MKE, a pole position identification has to be conducted. For details, please refer to the documentation of the drive. 9

5.3 LynxDrive-20C-AO-H-MEE (-MKE / -ROO) MD-Name MD-Nr.: [Unit] LynxDrive-20C Ratio 30 50 80 100 120 160 Encoder pulse number 1005/31020 n 1 [I/U] Actual value sensing configuration Motorcode 1102 MEE: 512 MKE: 16 1011 Factory setting 2000 (611D) 1999 (611U) Rated motor current 1103 I N [A rms ] 2,0 2,0 1,7 1,4 1,2 0,9 Maximum motor current 1104 I max [A rms ] 2,6 3,2 2,6 2,3 2,0 1,6 Number of pole pairs 1112 p [ ] 5 Motor torque constant 1113 k TM [Nm/A rms ] 0,39 Motor voltage constant 1114 k EM [V/1000 rpm] Armature resistance (L-N, 20 C) 1115 R L-N [Ω] 3,6 Armature inductance (L-N) 1116 L D [mh] L str. * 1,5 Moment of inertia 1117 J [kgm²] 0,000037 (0,000043 with brake) Motor zero speed current 1118 I 0 [A rms ] 2,0 2,0 1,7 1,4 1,2 0,9 Motor current limit (only611u) 1122 I max [A rms ] 2,6 3,2 2,6 2,3 2,0 1,6 Optimum load angle 1128 [ ] 90 Maximum motor speed 1146 n max [rpm] 6500 Reluctance torque constant 1149 [mh] 0 Lower current limit adaption 1180 [%] Upper current limit adaption 1181 [%] Factor current controller adaption 1182 [%] 26 10,5 0% Rated motor speed 1400 n N [rpm] 3500 Alarm threshold motor over Shutdown limit motor 1602 [ C] 100 1607 [ C] 120 When using actuators with feedback type MKE, a pole position identification has to be conducted. For details, please refer to the documentation of the drive. When using actuators with feedback type MEE or ROO, the pole position is already adjusted according to the requirements of the drive manufacturer. A pole position identification is not necessary. 10

5.4 LynxDrive-25C-AR-H-MEE (-MKE / -ROO) MD-Name MD-Nr.: [Unit] LynxDrive-25C Ratio 30 50 80 100 120 160 Encoder pulse number 1005/31020 n 1 [I/U] MEE: 512 MKE: 16 Actual value sensing configuration 1011 Factory setting Motorcode 1102 2000 (611D) 1999 (611U) Rated motor current 1103 I N [A rms ] 2,6 2,1 2,0 2,0 1,7 1,3 Maximum motor current 1104 I max [A rms ] 3,5 3,9 3,3 3,1 2,7 2,2 Number of pole pairs 1112 p [ ] 7 Motor torque constant 1113 k TM [Nm/A rms ] 0,58 Motor voltage constant 1114 k EM [V/1000 rpm] 38 Armature resistance (L-N, 20 C) 1115 R L-N [Ω] 1,2 Armature inductance (L-N) 1116 L D [mh] L str. * 1,5 Moment of inertia 1117 J [kgm²] 0,000178 (0,0002 with brake) Motor zero speed current 1118 I 0 [A rms ] 2,6 2,1 2,0 2,0 1,7 1,3 Motor current limit (only611u) 1122 I max [A rms ] 3,5 3,9 3,3 3,1 2,7 2,2 Optimum load angle 1128 [ ] 90 Maximum motor speed 1146 n max [rpm] 4800 Reluctance torque constant 1149 [mh] 0 Lower current limit adaption 1180 [%] 0% Upper current limit adaption 1181 [%] Factor current controller adaption 1182 [%] 4,8 Rated motor speed 1400 n N [rpm] 3500 Alarm threshold motor over 1602 [ C] 100 Shutdown limit motor 1607 [ C] 120 When using actuators with feedback type MKE, a pole position identification has to be conducted. For details, please refer to the documentation of the drive. When using actuators with feedback type MEE or ROO, the pole position is already adjusted according to the requirements of the drive manufacturer. A pole position identification is not necessary. 11

5.5 LynxDrive-32C-AR-H-MEE (-MKE / -ROO) MD-Name MD-Nr.: [Unit] LynxDrive-32C Ratio 30 50 80 100 120 160 Encoder pulse number 1005/31020 n 1 [I/U] Actual value sensing configuration Motorcode 1102 MEE: 512 MKE: 16 1011 Factory setting 2000 (611D) 1999 (611U) Rated motor current 1103 I N [A rms ] 4,4 4,2 3,9 4,0 3,4 2,6 Maximum motor current 1104 I max [A rms ] 6,4 8,3 7,1 6,2 5,5 4,3 Number of pole pairs 1112 p [ ] 7 Motor torque constant 1113 k TM [Nm/A rms ] 0,58 Motor voltage constant 1114 k EM [V/1000 rpm] 38 Armature resistance (L-N, 20 C) 1115 R L-N [Ω] 1,2 Armature inductance (L-N) 1116 L D [mh] L str. * 1,5 Moment of inertia 1117 J [kgm²] 0,000295 (0,000312 with brake) Motor zero speed current 1118 I 0 [A rms ] 4,4 4,2 3,9 4,0 3,4 2,6 Motor current limit (only611u) 1122 I max [A rms ] 6,4 8,3 7,1 6,2 5,5 4,3 Optimum load angle 1128 [ ] 90 Maximum motor speed 1146 n max [rpm] 4800 Reluctance torque constant 1149 [mh] 0 Lower current limit adaption 1180 [%] 0% Upper current limit adaption 1181 [%] Factor current controller adaption 1182 [%] 4,8 Rated motor speed 1400 n N [rpm] 3500 Alarm threshold motor over 1602 [ C] 100 Shutdown limit motor 1607 [ C] 120 When using actuators with feedback type MKE, a pole position identification has to be conducted. For details, please refer to the documentation of the drive. When using actuators with feedback type MEE or ROO, the pole position is already adjusted according to the requirements of the drive manufacturer. A pole position identification is not necessary. 12

5.6 LynxDrive-40C-AT-H-MEE (-MKE / -ROO) MD-Name MD-Nr.: [Unit] LynxDrive-40C Ratio - 50 80 100 120 160 Encoder pulse number 1005/31020 n 1 [I/U] MEE: 512 MKE: 16 Actual value sensing configuration 1011 Factory setting Motorcode 1102 2000 (611D) 1999 (611U) Rated motor current 1103 I N [A rms ] - 5,8 5,5 5,8 5,8 4,4 Maximum motor current 1104 I max [A rms ] - 13,4 10,2 8,9 8,0 6,2 Number of pole pairs 1112 p [ ] 7 Motor torque constant 1113 k TM [Nm/A rms ] 0,71 Motor voltage constant 1114 k EM [V/1000 rpm] Armature resistance (L-N, 20 C) 1115 R L-N [Ω] 0,65 Armature inductance (L-N) 1116 L D [mh] L str. * 1,5 3,75 Moment of inertia 1117 J [kgm²] 0,000786 (0,000827 with brake) Motor zero speed current 1118 I 0 [A rms ] - 5,8 5,5 5,8 5,8 4,4 Motor current limit (only611u) 1122 I max [A rms ] - 13,4 10,2 8,9 8,0 6,2 Optimum load angle 1128 [ ] 90 Maximum motor speed 1146 n max [rpm] 4000 Reluctance torque constant 1149 [mh] 0 Lower current limit adaption 1180 [%] Upper current limit adaption 1181 [%] Factor current controller adaption 1182 [%] 46 0% Rated motor speed 1400 n N [rpm] 3000 Alarm threshold motor over Shutdown limit motor 1602 [ C] 100 1607 [ C] 120 When using actuators with feedback type MKE, a pole position identification has to be conducted. For details, please refer to the documentation of the drive. When using actuators with feedback type MEE or ROO, the pole position is already adjusted according to the requirements of the drive manufacturer. A pole position identification is not necessary. 13

5.7 LynxDrive-50C-AW-H-MEE (-ROO) MD-Name MD-Nr.: [Unit] LynxDrive-50C Ratio - 50 80 100 120 160 Encoder pulse number 1005/31020 n 1 [I/U] MEE: 512 Actual value sensing configuration 1011 Factory setting Motorcode 1102 2000 (611D) 1999 (611U) Rated motor current 1103 I N [A rms ] - 2,4 5,8 5,9 6,0 4,7 Maximum motor current 1104 I max [A rms ] - 13,0 10,6 8,9 8,2 6,8 Number of pole pairs 1112 p [ ] 7 Motor torque constant 1113 k TM [Nm/A rms ] 1,25 Motor voltage constant 1114 k EM [V/1000 rpm] Armature resistance (L-N, 20 C) 1115 R L-N [Ω] 0,68 Armature inductance (L-N) 1116 L D [mh] L str. * 1,5 5,6 Moment of inertia 1117 J [kgm²] 0,00179 (0,00185 with brake) Motor zero speed current 1118 I 0 [A rms ] - 2,4 5,8 5,9 6,0 4,7 Motor current limit (only611u) 1122 I max [A rms ] - 13,0 10,6 8,9 8,2 6,8 Optimum load angle 1128 [ ] 90 Maximum motor speed 1146 n max [rpm] 3500 Reluctance torque constant 1149 [mh] 0 Lower current limit adaption 1180 [%] Upper current limit adaption 1181 [%] Factor current controller adaption 1182 [%] 80,5 0% Rated motor speed 1400 n N [rpm] 2500 Alarm threshold motor over Shutdown limit motor 1602 [ C] 100 1607 [ C] 120 When using actuators with feedback type MEE or ROO, the pole position is already adjusted according to the requirements of the drive manufacturer. A pole position identification is not necessary. 14