SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638

Similar documents
BioSTEP Screened Pumping System Installation & Service Manual

FOG Hog Grease Interceptor System Installation & Service Manual FOR USE WITH FOGHog FH-20, FH0-35, FH-50, FH-75, and FH-100

SEPTIC TANK PUMP VAULT FILTER SYSTEM PUMP VAULT INSTALLATION AND SERVICE MANUAL

Modular Outdoor Fountain System

Installation Manual. D3600- Series Duplex Grinder Systems. Contents

APCO ASR-400/450 SEWAGE AIR RELEASE VALVES

OSCAR- LOWeFLOW Treatment System Homeowner s Manual. January 2016

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

Installation Manual. Q Series Quadplex Grinder Systems. Contents

PUMP VAULT S.T.E.P. SYSTEM

PRE-PLUMBED SEWAGE SYSTEM

Wastewater Combination Air Valve. Operation, Maintenance and Installation Manual

Air Curtain. Installation, Operating and Maintenance Instructions

Access Riser Fits PRO370 and PRO380 Series

2460 / 2472 / Series Simplex Grinder Systems

Pump Installation and Service Manual JB-1 System Sewage Ejector Pump Package

ClariMax Inclined Plate Clarifier. Installation, Operation & Maintenance Manual

INSTALLATION AND OPERATING INSTRUCTIONS FOR CONCRETE VAULT TYPE UNITS

Operating and Installation Instructions

Installation & Operation Instructions For EZ Klear Systems Model EZK-25

Recirculating Media Filters OWNER'S MANUAL

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Model 8309WC Barrier Free Shower & Eye/Face Wash

INSTALLATION, INSTRUCTION AND SERVICE MANUAL

Model 8309WC Barrier Free Shower & Eye/Face Wash

DOWNSPOUT DIVERTER SYSTEM

StormPro BA Series Sump Pump

Model 8346/8346CRP Shower & Eye/Face Wash

OPERATIONS MANUAL MODEL MT-500

Model 8317 Combination Shower Eye/Face Wash

AMERICAN RECIRCULATING SAND FILTER SYSTEMS

AEROMOTIVE Part # & Mustang 5.0L Stealth Fuel System Kit INSTALLATION INSTRUCTIONS

2-Pack Indoor Simulated Dome Security Cameras

Model 6518FR. NOTE TO INSTALLER: Please leave this information with the Maintenance Department. LIMITED WARRANTY

INSTALLATION, OPERATION & MAINTENANCE INSTRUCTIONS AIR-COOLED AFTERCOOLER FOR COMPRESSED AIR SYSTEMS MODELS AC-140 thru AC-220 (ALL VOLTAGES)

Giant Cone Display Case

MGFHVLP. Instructions/Parts. Mini Gravity Feed System E. Part No Includes MGFHVLP Mini Gravity Feed Spray Gun and MGC 125 Gravity Cup.

SUBMERSIBLE SUMP PUMPS

FPS-500. Fuel Polishing System Eliminates Microbial Contamination. Operating Manual

ESE Series Cast Iron Sewage Pumps

Installation and Operating Procedures

Wastewater Air Release Valve Models 48A, 49A

PENBERTHY MODELS GL AND GH GAS OPERATED JET PUMPS INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

LESTRONIC II BATTERY CHARGER BUILT-IN OR PORTABLE CHARGERS

5220 SERIES Z-Cell OWNER'S MANUAL

RETROFIT SYSTEMS INSTALLATION AND SERVICE MANUAL. Engineered for quick and easy replacement of existing progressive cavity grinder systems.

ATD Gallon Pressurized Oil Drain Owner s Manual

Val-Matic 1/2-3 Well Service Air Valve With Dual Port Throttling Device

RSV16 Retro-Fit Cartridge Acorn Controls SV16 Valve Cartridge

IMPORTANT SAFETY INSTRUCTIONS

Owner s Manual VersaTile VT1200 Hard Surface Cleaner

P-200 Plastic Utility Pump for Petroleum Products

D Instructions/Parts. Siphon Feed Detail Spray Gun D

½"-3" Air/Vacuum Valve Models 100S to 103S

SUBMERSIBLE SUMP PUMPS

AEROMOTIVE Part # GM LS1 Fuel Rails INSTALLATION INSTRUCTIONS

APCO CRF-100A RUBBER FLAPPER SWING CHECK VALVES

WSB clean: Installation Manual

Read and follow all instructions. Safety can only be ensured if the walker is assembled and operated according to these instructions.

25 GALLON PORTABLE OIL LIFT

Automatic Butter Dispenser Instruction Manual Model #2395NS

QUICK START GUIDE OWNER S MANUAL AL50 SERIES SAND FILTRATION TECHNOLOGY PLEASE CALL DO NOT RETURN TO STORE

20A Solar Charge Controller

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

HYDR-O-RAIL SYSTEM. Pump Installation and Service Manual

Nelsen Filtration Cartridge Systems

DISTRIBUTED BY TULSA CHAIN.COM, LLC.

WATERBLAST HOSE REEL SYSTEM HWB HOSE REEL OPERATION AND MAINTENANCE MANUAL W A T E R J E T T O O L S

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Installation Instructions

To assemble your equipment read entire manual and follow all instructions.

StormPro BCV400 Sewage Ejector Pump

Export Bucket Pump Instruction Manual Models: 2114XE & 2114XD

Voltmaster Centrifugal Trash Pumps

AEROMOTIVE Part # Fuel System Prime Kit INSTALLATION INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Accu-Meter Oil Pump. Instruction Manual. Model #2114. Cincinnati, OH USA. Part No Revised June 1996

Installation, Operation & Maintenance Manual. TotlSep (TS) Series. FRP Oil/Water Separator

INSTALLATION & OPERATING INSTRUCTIONS: REVOLUTION SPINEBOARD ATTACHMENT WARNING

Model C230 Pump Controller

INSTALLATION AND OPERATION MANUAL

HALLMARK INDUSTRIES INC

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

E-Z Treat Installation Guidelines

Model LA 4400 Time Delay OFF Controller

A171 Series Barrier Free, Wall Mounted Fountain

TECHNICAL ASSISTANCE TOLL FREE TELEPHONE NUMBER TECHNICAL ASSISTANCE FAX:

EQUIPMENT OWNERS MANUAL MATTHIESEN HEAVY DUTY SHAKER

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

2 INLET / HIGH HEAD DRAIN PUMP SYSTEMS MODELS , INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

TITAN FLOW CONTROL, INC.

CSA products for waste water. Combination air valve. Mod. SCF 2

Owner s Manual & Safety Instructions

Sample Pro 3/4" Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

GA-160 Gas Amplifier

Transcription:

SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638 SaniTEE Manual Bio-Microbics, Inc. Revised December 2009. SaniTEE is a registered trademark of Bio-Microbics, Inc.

INSTALLATION & SERVICE MANUAL FOR USE WITH SNT416, SNT418, SNT818, SNT838, SNT1618, SNT1638 GENERAL INFORMATION If you have questions regarding any Bio-Microbics products, please contact us: 800-753-FAST (3278) or (913) 422-0707 e-mail: onsite@biomicrobics.com DELIVERY INSPECTION SaniTEE screens are carefully manufactured and inspected at the factory prior to shipment. Before and after uncrating the unit, check the packaging for signs of shipping damage. If there is evidence of damage or abuse, notify Bio-Microbics, Inc. at (800) 753-3278 or (913)422-0707. About SaniTEE Wastewater Screens SaniTEE self-cleaning wastewater deflection screens (commonly known as septic tank effluent filters) are designed to reduce suspended solids discharged in septic tank effluent by promoting natural sedimentation and excluding gas-lifted particles from entering the outlet pipe. Additionally, SaniTEE s patented keyhole weir helps to attenuate surge flows, delivering a more consistent flow for further treatment or dispersal. These features help extend the life of a drain field, reduce orifice clogging in effluent disposal systems and allow flexibility in the use of different types of effluent pumps. B A. Tank Inlet A H C D E B. Swab Handle C. Cap D. Outlet Diverter (not included with SNT416 & 418) E. SaniTEE Screen F F. Interior Cleaning Swab (Exterior Swab included with SNT818, 838, 1618 & 1638) G G. Settled Sludge H. Scum Layer Only qualified service staff should open access ports and/or covers. Infectious organisms exist in

a septic tank. If any contact with wastewater, immediately wash and disinfect all exposed areas and contact personal physician. Failure to do so could result in severe sickness or death. LOCATION Hazards exist in confined spaces such as a septic tank. All confined space precautions must be followed if entering a tank. Always keep tank openings covered during storage and installation SaniTEE screens are located on the outlet(s) or baffle walls of septic tanks and may be located in the same position relative to the house and water supply as any conventional septic system. However, some basic guidelines should be followed: 1. Avoid locating any septic tank in high groundwater areas where the tank could possibly float up and become dislodged. 2. The SaniTEE device should be placed in the manhole as close as possible to the tank s outlet end. This manhole should have a minimum diameter of 18. 3. The SaniTEE device should be placed in the center of this manhole. MATERIALS REQUIRED FOR INSTALLATION Note: other tools may be needed to complete installation. 1. Septic tank that meets all applicable requirements and standards 2. Optional ¾ [19 mm] schd 80 PVC pipe & fittings to extend swab handles. 3. PVC saw 4. PVC primer and glue (weather appropriate) 5. Outlet sealing material or gasket (may be included with septic tank) 6. FOR SaniTEE SNT416 and SNT418 ONLY: Outlet tee or sweep (schd 35, 40 or 80) 7. FOR SaniTEE SNT818, SNT838, SNT1618 and SNT1638 ONLY: Anchor bolts for securing SaniTEE top diverter to the tank. 8. Hammer drill and masonry bits SYSTEM COMPONENTS SaniTEE 416 & 418 SUPPLIED EQUIPMENT COMMON NAME PART NUMBER 1 Handle 180-HAN3/4 2 Lid 180-TC 3 Swab Shaft 180-SPVC3/4 4 4 SaniTEE Body 175-1/16FINSNTE (416) 1 /16 slots 175-1/8FINSNTE (418) 1 /8 slots 5 Internal Swab 180-4SWAB

SaniTEE 818 & 838 SUPPLIED EQUIPMENT COMMON NAME PART NUMBER 1 Handles (3)180-HAN3/4 2 Top Cap 180-CAPSTPPH8 3 Top Diverter 180-DT8 4 Internal Swab 180-SWBINT8 5 8 SaniTEE Body 180-SANSNMB818 (818) 1 /8 slots 180-SANSNMB838 (838) 3 /8 slots 6 External Swab Shafts (2) 180-SPVC3/4 7 External Swab 180-SWBEXT8 SaniTEE SNT1618 & SNT1638 SUPPLIED EQUIPMENT COMMON NAME PART NUMBER 1 Handles (3) 180-HAN3/4 2 Top Cap 180-CAPSTPPH16 3 External Swab Shafts (2) 180-SPVC3/4 4 Top Diverter 180-DT16 5 Internal Swab 180-SWBRINT16 6 16 SaniTEE Body 180-SANSNMB (1618) 1 /8 slots 180-SANSNMB (1638) 3 /8 slots 7 External Swab 180-SWBREXT16

INSTALLATION PROCEDURE SNT416 & SNT418 1. A 4 SaniTEE fits a standard 4 septic tank outlet tee or sweep (Schd 35, 40 & 80). The center of the SaniTEE MUST be at least 38 inches [96.5 cm] off the bottom of the tank. a. A short section of pipe may be attached to the bottom of the outlet tee to retain floatables. 2. Place the SaniTEE into the outlet tee. DO NOT USE GLUE. The SaniTEE should fit snugly into the outlet tee. 1a 3. OPTIONAL - EXTENDING SWAB HANDLES The exterior cleaning swab pipes may be easily extended using ¾ schd 80 pipe and matching couplings. Cut ¾ pipes to the desired length, glue and connect each extension pipe to the existing pipes using slip-to-slip couplings. When completed, glue the supplied swab handle to each pipe end. 4. Reattach the SaniTEE handle with solvent welding to the ¾ Schd 80 swab shaft or added extension pipe.

INSTALLATION PROCEDURE SNT818, 838, 1618 & 1638 2 1 SNT818 & SNT838 1. Install the Top Diverter using concrete anchor bolts (general rules for anchoring into concrete dictate bolt penetration 50% of wall). Assure that it is placed correctly with respect to the manhole and other features of the tank. See the drawings of each SaniTEE model for precise dimensions. Properly seal any areas to prevent leaking. 2. Place the SaniTEE into the Top Diverter. The SaniTEE should fit snugly into Top Diverter with the Top Diverter key fitting into the SaniTEE notch. SNT1618 & SNT 1638 3. 3. OPTIONAL EXTENDING SWAB HANDLES The exterior cleaning swab pipes may be easily extended using ¾ schd 80 pipe and matching couplings. Cut ¾ pipes to the desired length, glue and connect each extension pipe to the existing pipes using slip-to-slip couplings. When completed, glue the supplied swab handle to each pipe end. 4. Reattach the SaniTEE handles by solvent welding them to the ¾ Schd 80 swab shafts. 4 3

FINAL INSTALLATION INSPECTION & START UP It is the responsibility of the installer to ensure that the septic tank containing the SaniTEE will not float due to hydraulic conditions at the site. Your local Bio-Microbics distributor may provide installation inspection services. If you have questions, call Bio-Microbics at 800-753-FAST (3278) or (913) 422-0707. Always secure all access covers in place so that people cannot enter the tank, without the use of proper tools. DO NOT use flame or spark near a septic tank s access points. Gases emanating from septic tanks can explode if ignited or deadly if inhaled. BEFORE THE UNIT IS BACKFILLED: A. Fill the tank to the normal operating level. B. Check for leaks in all water-tight seals. C. Backfill the excavation. D. Lastly, record all pertinent information at the end of this manual (please note, SaniTEE s do not have a serial number, but maybe used in conjunction with a FAST system that can be referenced with). OPERATION & MAINTENANCE Simple maintenance The SaniTEE should be swabbed annually or cleaned each time the septic tank is pumped. If sewage flow is noticeably slowed by the SaniTEE, more frequent cleanings may be necessary. For installations other than single-family homes, more frequent cleaning may be necessary. Inspect the SaniTEE as needed to make that determination. Always secure all access covers in place so that people cannot enter the tank, without the use of proper tools. DO NOT use flame or spark near a septic tank s access points. Gases emanating from septic tanks can explode if ignited or deadly if inhaled. Only qualified service staff should open access ports and/or covers. Infectious organisms exist in a septic tank. If any contact with wastewater, immediately wash and disinfect all exposed areas and contact personal physician. Failure to do so could result in severe sickness or death. CLEANING SaniTEE : 1. Grasp the handle(s) of the cleaning swab and forcefully move up and down several times, extending the entire length of the screen. For the 8 & 16 models, MOVE THE SWAB HANDLES EVENLY. Be sure to clean with both swabs. Optional: If a more thorough cleaning is desired, remove the SaniTEE out of the outlet/top diverter and rinse the device off. If sludge builds up on the bottom of the SaniTEE screen or if required cleaning becomes more frequent than usual, check the tank s sludge levels as it may need to be pumped. Good septic system maintenance includes regular removal of sludge. Check with local officials for recommendations or requirements.

LIMITED WARRANTY Bio-Microbics, Inc. warrants that the SaniTEE product will be free from defects in material and workmanship for a period of one year from the date of purchase. During the warranty period, if any part is defective or fails to perform as specified when operating at design conditions, and if the equipment has been installed and is being operated and maintained in accordance with the written instructions provided by Bio-Microbics, Inc., Bio-Microbics, Inc. will repair or replace at its discretion such defective parts free of charge. Defective parts must be returned by owner to Bio-Microbics, Inc.'s factory shipping pre-paid, if so requested. The cost of labor and all other expenses resulting from replacement of the defective parts and from installation of parts furnished under this warranty shall be borne by the owner. This warranty applies only to the SaniTEE screen and does not include any of the plumbing, drainage, septic tank or disposal system. Bio-Microbics, Inc. reserves the right to revise, change or modify the construction and/or design of the SaniTEE screen, or any component part or parts thereof, without incurring any obligation to make such changes or modifications in present equipment. Bio-Microbics, Inc. is not responsible for consequential or incidental damages of any nature resulting from such things as, but not limited to, defect in design, material, or workmanship, or delays in delivery, replacements or repairs. THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESSED WARRANTIES. ANY WARRANTY IMPLIED BY LAW, INCLUDING WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS IN EFFECT ONLY FOR THE WARRANTY PERIOD SPECIFIED ABOVE. NO REPRESENTATIVE OR PERSON IS AUTHORIZED TO GIVE ANY OTHER WARRANTY OR TO ASSUME FOR BIO-MICROBICS, INC., ANY OTHER LIABILITY IN CONNECTION WITH THE SALE OF ITS PRODUCTS. Contact your local distributor for parts and service.