DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection

Similar documents
QUALITY ASSURANCE & DOCUMENTATION

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

RESIDUAL CURRENT CIRCUIT BREAKER

PD-Series Ground Fault Circuit Protection

MM5 Series High Breaking Mini Circuit Breakers

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

Power systems Protection course

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

DX³ RCCBs - ID 4P up to 100 A

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Residual current devices

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Technical Journal September 2012

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

New DX 3 High rating & breaking capacity

TX³ RCCBs 2P up to 100 A

COMBINATION CIRCUIT BREAKERS RCBO

DX³ 4-pole RCBO 6000 A/10 ka

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Low Voltage A GE Power Controls Company. General catalogue

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

3 Pin Schuko Converter Plug Technical Data & Fitting Instructions

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Menu. Home About this portal Latest updates. Print Save Resource detail Citations. Table of Contents

The young energy ensures more safety

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Electronic circuit breaker EBU10-T

Domae. The right solution for distribution boards

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

RX 3 M.C.B A up to 63 A

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

KEWTECH. KT56 digital multi function tester. Instruction manual

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

RX 3 M.C.B A up to 63 A

R.C.B.O. SP / 1 module

CONTENTS Part I Intelligent Air Circuit Breaker(ACB) 01 UEW5 series Intelligent Air Circuit Breaker Part II Molded Case Circuit Breaker(MCCB)

DPX moulded case circuit breakers

DSE201 Compact design with enhanced protection

Molded Case Circuit Breakers Solid-state trip types

KM1 Series Moulded Case Circuit Breaker

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Essential equipment for all your requirements

3 - Protection components Motor circuit-breakers

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

PB-Series. GFCI/ELCI & Panel Seal

Residual current circuit breakers with conditional shortcircuit

Btdin RCBO 6000A up to 63A (2P)

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

CORE VALUES TECHNOLOGIES ESS-ESD PRODUCT CATALOGUE Enjoy the peace of mind ENGINE POWER SUPPLIERS AND EQUIPMENT HEAT

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

(1,5 modules per pole)

COMPLETE SOLUTIONS FOR POWER PROTECTION

Miniature Circuit-Breakers (MCBs)

C60H-DC C curve. Catalogue numbers

W DATA SHEET: COMBINED RCD/MCB DEVICES BO, 3-POLE

Cat N 3. OVERALL DIMENSIONS

PRODUCTS FOR ELECTRIC VEHICLE CHARGING STATIONS

Thermal-Magnetic Circuit Breaker M1-...

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

DPX 1600 Electronic release

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Circuit Breakers. Switching & Controls. Selection Guide NC1V Series Dimensions...

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Technical Information

PS6R 480W Switching Power Supply

DX³ RCBO 6000 A Phase + Neutral, neutral right side

Circuit Breaker Prepared By :

Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

GB/T Translated English of Chinese Standard: GB/T

Residual Current Circuit-breaker (RCCB) FH 200 Series

Softstarter Intelligent Controllers

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

cor Long Run Experience

Protection components

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

NDM1 Series MCB Edition

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

Technical data for manual motor starters Type MS325

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

NRA Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

SubDrive Inline Constant pressure controller Additional information for Australia, NZ TOLL FREE HELP 1300 FRANKLIN

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

Moulded Case Circuit Breakers

MCBs and RCDs LR TM 6000

Phoenix Inverter

Transcription:

DZ47LE 1P+ DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection DZ47LE C45LE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage 1 phase 30V and 3 phase 400V, rated current up to 63A. When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value, the RCBO can cut off the power within the time of s automatically to protect the personal safety and preventing the equipment from the fault resulted by the residual current. With this function, the RCBO can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions. It conforms to IEC61009 standard. ormal Operation and Mounting Requirement Circumstance temperature 5 C~+40 C, average temperature not exceeding 35 C. Altitude above sea level less than 000m. Humidity not exceeding 50% at 40 C and not exceeding 90% at 5 C. Installation class II or III. Pollution class II. Installation method DI Rail mounting type. The external magnetism shall not be more than 5 times of terrestrial one. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position. DZ47LE 3P umber of Poles Rated current (A) Rated operating current (ma) Rated non operating (IΔ)(mA) Rated voltage (V) Tripping curve Type 1P+, P, 3P, 3P+, 4P 6, 10, 16, 0, 5, 3, 40, 50, 63 30, 100, 300, 500 0/380 C, D Electronic Wiring Diagram C45LE 1P+ SinglePole Double Line DoublePole Double Line TriplePole Triple Line TriplePole Four Line FourPole Four Line C45+DZ47L C45+DZ47L C45+DZ47L C45+DZ47L C45+DZ47L C45+C45L C45+C45L C45+C45L C45+C45L C45+C45L 1/ / 3/3 3/4 4/4 Operation Principle C45LE 3P 1

C65LE Residual Current Circuit Breaker with Over Current Protection C65LE P C65LE RCBO is used for the protection against electrical leakage in the circuit of 50Hz or 60Hz, rated voltage singlephase 30V, 3 phase 400V, rated current up to 60A. When somebody gets an electric shock or the residual current of the circuit exceeds the fixed value, the ELCB can cut off the power within the time of s automatically to protect the personal safety and preventing the equipment from the fault resulted by the residual current. With this function, the ELCB can protect the circuit against overload and short circuit or can be used for the unfrequent switchover of the circuit under normal conditions. It conforms to IEC61009 standard. umber of Poles Rated voltage Rated current Rated operating current (ma) Rated nonoperating(iδn) Tripping Curve 1P+, P, 3P, 3P+, 4P 40/415V 6A 10A 16A 0A 5A 3A 40A 50A 63A 30mA 100mA 300mA C, D C65LE 4P C60LE Earth Leakage Circuit Breaker with Over Current Protection umber of Poles (A) P 10, 16, 0, 5, 3, 40 30, 100, 300 30 S 4500 Dimensions O.OFF 85.5 35.5 C60LE 36 7.5

DZ30LE(DPLE) Earth Leakage Circuit Breaker with Over Cur rent Protection umber of Poles 1P+ 6, 10, 16, 0, 5, 3 30 Rated Residual onoperation Current (IΔno)(mA) 15 30 S 4500A DZ30LE Overload Trip Characteristic Testing Current(A) 1.13In 1.45In.55In 5In 10In Rated Voltage(V) all all all all all Limited Time t 1h t<1h 1s<t<60s t s t<s Preengage Result nontrip trip trip nontrip trip Start Situation cold state heat state cole state cold state cole state ote The current rise steadily to a fixed value within 5s Open the supplementary switch, connect the power Open the supplementary switch, connect the power Open the supplementary switch, connect the power Dimensions C100LE 1P+ C100LE 3P C100LE Residual Current Circuit Breaker with Over Current Protection C100LE RCBO is suitable for the circuit of 50Hz, rated voltage 30/400V, and rated current up to 100A. It has the earth leakage, overload & short circuit protect function. It can also add over voltage protect function. It is mainly used in building illumination and electrical distribution system. umber of Poles 1P+, P, 3P, 3P+, 4P 40, 50, 63, 80, 100 30, 50, 100, 00, 300 Rated Residual onoperation Current (IΔno)(mA) AC 30/400 S 4000 Tripping Curve C, D 3

F360 Residual Current Circuit Breaker F360 P(EW) The RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. The RCCB is mainly suitable for use in varieties of plants and enterprises, building construction 1 phase 30V and 3 phase 400V 50/60Hz. RCCB is not suitable for use on DC pulse system. F360 4P(EW) umber of Poles Rated Residual onoperation Current (IΔno)(mA) Residual Operating Current Scope Type P, 4P 16, 0, 5, 3, 40, 50, 63, 80 30, 100, 300 AC 30/40 AC 400/415 0.5IΔn~IΔn 0.3S A Type,AC Type Operation Principle 1 3 1 3 5 7 4 4 6 8 F360 P Overall And Mounting Dimensions (Unit: mm) 69 68 44 6.3 17.5 35 17.5 17.5 17.5 17.5 70 17.5 17.5 17.5 90.4 90.4 71 46 90.4 71 46 F360 4P 7.5 7.5 4

ID Residual Current Circuit Breaker ID P ID RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. The RCCB is mainly suitable for use in varieties of plants and enterprises, building construction 1 phase 30V and 3 phase 400V 50/60Hz. RCCB is not suitable for use on DC pulse system. ID 4P FI P umber of Poles Residual Operating Current Scope 1P+, 3P+ 16, 0, 5, 40, 50, 63 30, 100, 300, 500 AC 30/40 AC 400/415 0.5IΔn~IΔn 0.3S 6000A 4000 FI Residual Current Device FI 4P The Residual Current Device FI is in conformity with the standard of IEC61008, VDE0664,CEE7 and BS463 It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Thus it is suitable to avoid the shock hazard and fire caused by earth leakage. FI RCD is mainly suitable for using in varieties of plants, enterprises, buildings, constructions, commerce, guesthouses and families. It can be used in circuits of 1 phase 30V and 3 phase 400V 50/60Hz. FI1 P FI1 4P umber of Poles Rated Residual onoperation Current (IΔno)(mA) P, 4P 16, 0, 5, 3, 40, 50, 63, 80, 100 30, 100, 300, 500 AC 30/400 S 4000 5

FI Residual Current Device FI P Residual Current Device(RCD) FI is in conformity with the standard of IEC61008. It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Thus it is suitable to avoid the shock hazard and fire caused by earth leakage. FI ELCB is mainly suitable for varieties of plants and enterprises, buildings, construction, commerce, hotels and families. It can be used in circuits of 1 phase 30V and 3 phase 400V 50/60Hz. FI 4P umber of Poles Rated Residual onoperation Current (IΔno)(mA) P, 4P 16, 0, 5, 3, 40, 50, 63 30, 100, 300, 500 AC 30/400 S 4000 ormal Operation and Mounting Requirement Circumstance temperature 5 C~+40 C, average temperature not exceeding 35 C. Altitude above sea level less than 000m. Humidity not exceeding 50% at 40 C and not exceeding 90% at 5 C. Installation class II or III. Pollution class II. Installation method DI Rail mounting type. The external magnetism shall not be more than 5 times of terrestrial one. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position. Operation Principle 74±0.8 L1 L1 L L3 L1 Overall And Mounting Dimensions (Unit: mm) 30 5.5 35±0.3 0.5 75±0.8 45 L1 L L3 Ø7.5 L1 L L3 L1 L L3 70±0.5 Ø4.3 T I 6

RC Residual Current Device RC1 P RC Residual Current Device is in conformity with the standard of IEC61008. It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Thus it is suitable to avoid the shock hazard and fire caused by earth leakage. The product is mainly suitable for using in varieties of plants, enterprises, buildings, constructions, commerce, guesthouses and families. It can be used in circuits of 1 phase 30V and 3 phases 400V 50/60Hz. RC1 4P umber of Poles Rated Residual onoperation Current (IΔno)(mA) P, 4P 16, 0, 5, 3, 40, 50, 63, 80, 100 30, 100, 300, 500 AC 30/400 S 4000 Operation Principle L1 L1 L L3 L1 L1 L L3 RC P Overall And Mounting Dimensions (Unit: mm) 75±0.8 5 35.6±0.3 71.±0.5 35±0.3 O.OFF Test 86±0.8 45 O.OFF Test RC 4P 7

F7 Residual Current Device F71 P The Residual Current Device F7 is in conformity with the standard of IEC61008. It can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk line. Thus it is suitable to avoid the shock hazard and fire caused by earth leakage. F7 RCD is mainly suitable for using in varieties of plants, enterprises, buildings, constructions, commerce, guesthouses and families. It can be used in circuits of 1 phase 30V and 3 phases 400V 50/60Hz. F71 4P umber of Poles Rated Residual onoperation Current (IΔno)(mA) P, 4P 16, 0, 5, 3, 40 50, 63 30, 100, 300, 500 AC 30/400 S 1500A 4000 Operation Principle 1 1 3 5 F7 P 4 6 Overall And Mounting Dimensions (Unit: mm) 75±0.8 35±0.3 70±0.5 5.5 1 1 3 5 36±0.3 T 80±0.8 45 T 4 6 F7 4P 8

BVD Residual Current Device BVD P Design according to Tripping time Rated voltage Rated tripping current Sensitivity Rated short Circuit strength Maximum bakcup fuse for Short circuit protection Maximum backup fuse for Overload protection Resistance to climatic conditions Degree of protection electrical comp. mech comp. ICE 1008 (E 61008) undelayed min.10 ms delay min.40 ms delay with selective disconnecting function 30/400V; 50Hz 10, 30, 100, 300, 500mA AC and pulsating DC 10KA with 63A gl backup fuse 10KA with 80A gl (F780 and 863) 6KA (rated current 63A) with 63A gl 63A gl 80 A gl (F780 and 863) 45 A gl (F7 5 and 40 A) 40 A gl(f7 80 A) according to IEC 1008 builtin switch IP 40 4.000 operating cycles 0.000 operating cycles BVD 4P KD Residual Current Device Earth leakage circuit breaker KD is suitable for the circuit of AC 50/60Hz,rated voltage 50V,and rated current up to 30A,It can cut off the circuit immediately on the occasion of shock hazard and fire caused by earth leakage.and it is especially used in household and public building,and this product conforms to GB16916.1/EC1008.1 standard. KD Pole Rated voltage Ui(V) Rated current(a) Rated leakage operating current Rated leakage dead current Leadage operating time Mechanical and electrical endurance P AC 40V 30A 15mA 30mA 7.5mA 15mA T s 4000 times 9

5SM Residual Current Device 5SM P 5SM 4P Series 5SM earth leakage breakers apply to in AC circuit of 50Hz,rated voltage up to 415V,rated current up to 80A.It is mainly used as an indirect contact protection for human. It also can be used to prevent against the fire danger caused by earth fault current owing to equipment insulation damage.when the proective measures of the electric shock are out of work,the RCCB whose rated residual operating current less than 30mA can serve as the supplementary protection for in direct contact,but it can t be used as the sole direct contact protection. Product features 1.Series 5SM1 Leakage breaker are the protector for pure electromagetic residual current operation..the operation function is unrelated to circuit voltage,but operation is reliable. 3.It can be reliably operated on the less of phase or neutral. 4.The capacity of resisting electromagnetic interference is strong. Main Technical Data Type 5SM1 P 5SM1 4P Un(V) Hz 40 415 50, 60 Im I m Inc InA I n I m ma 500A 6,10, (In 16,5, 50A 6000A 3,40, 10In) (In 50,63, 50A) 80 500A 6,10, (In 16,5, 50A 6000A 3,40, 10In) (In 50,63, 50A) 80 30 50 75 100 300 500 30 50 75 100 300 500 I no ma 15 5 40 50 150 50 15 5 40 50 150 50 The maximum of breaktime(s) I I 5I 5A 500A Dimension And Mounting 30

CT Residual Current Device Usage CT Residual Current Circuit Breaker without over current protection conforms to the standards of GB16916.1, IEC1008, BS493 etc. It is used in the circuits of AC 50~60Hz, single phase 30V(0V), three phases 400V(380V) in industrial & mining enterprises, commercial buildings and housing for protection of personal electric shock hazard and electric equipment and for unfrequent switchover of circuits under normal conditions. CT Mounting Instructions This RCD is intended for installation within an enclosure in an ambient temperature between 5 C and 40 C with an average value not exceeding 35 C over a 4 hour period. It should not be installed at an altitude greater than 000m above sea level, nor in an atmosphere subject to excessive pollution by smoke, dust, chemical fumes, salt laden spray, prolonged periods of high humidity or other abnormal conditions. See current product catalogues for a wide range of suitable enclosure. PG30 PG430 Earth Leakage Circuit Breaker PG30 & PG430 earth leagkage circuit breakers, the rated curent is adjustable form 10A up to 60A. User can select suitable current for better protection against overload and short circuit. The products comply with FC1450. PG30 Type Poles Rated voltage(v) Rated current(a) Leakage motion current(ma) Leakage dead current(ma) Standard PG30 PG430 P 4P 50V/440V 10, 15, 0, 30, 45, 50, 60A Ajustable 300mA, 500mA 300mA, 500mA 150mA, 50mA 150mA, 50mA FC 61450 PG430 31

F 1 Residual Current Circuit Breaker F1 P F1 RCCB is in conformity with the standard of IEC61008. The RCCB can cut off the fault circuit immediately on the occasion of shock hazard or earth leakage of trunk. Thus, it is suitable to avoid the shock hazard and fire caused by earth leakage. The RCCB is mainly suitable for use in varieties of plants and enterprises, building construction 1 phase 30V and 3 phase 400V 50/60Hz. RCCB is not suitable for use on DC pulse system. CF1 umber of Poles Rated Residual onoperation Current (IΔno)(mA) P, 4P 5, 3, 40, 63, 80, 100, 15 100, 300, 500 AC 30/400 S 4000 Operation Principle ormal Operation and Mounting Requirement Circumstance temperature 5 C~+40 C, average temperature not exceeding 35 C. Altitude above sea level less than 000m. Humidity not exceeding 50% at 40 C and not exceeding 90% at 5 C. Installation class II or III. Pollution class II. Installation method DI Rail mounting type. The external magnetism shall not be more than 5 times of terrestrial one. Product shall be installed vertically at the place where there shall be no severe impact and vibration. The product is switched on when the handle is at upper position. Overall And Mounting Dimensions (Unit: mm) 116 L1 L1 L L3 L1 L1 L L3 M.5 R. 90 90 98 35.5 8 3