RESIDUAL CURRENT CIRCUIT BREAKER

Similar documents
Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

The young energy ensures more safety

Perfection that Matters

Unrestricted. S.Mukhopadhyay

Miniature Circuit Breaker

DX³ RCCBs - ID 4P up to 100 A

TX³ RCCBs 2P up to 100 A

MINIATURE CIRCUIT BREAKER

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

DX³ 4-pole RCBO 6000 A/10 ka

Residual current devices

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Residual Current Circuit-breaker (RCCB) FH 200 Series

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Electrical Hazard Three factors determine the resistance of a substance to the flow of electricity: conductors insulators extreme caution

DPX moulded case circuit breakers

Schneider Electric India As a global specialist in energy management with operations in more than 00 countries, Schneider Electric offers integrated s

Electrical Workplace Safety

Basic. Electrical Safety. January 2009

Phase + Neutral, neutral on left side

(Miniature Circuit Breaker)

01 Spectra Plus - Introduction

DPX earth leakage DPX 3 -I earth leakage

DSE201 Compact design with enhanced protection

Phase + Neutral, neutral on right side

Btdin RCBO 6000A up to 63A (2P)

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Power systems Protection course

COMPLETE SOLUTIONS FOR POWER PROTECTION

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Thermal-magnetic Miniature Circuit Breaker 4230-T...

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Electronic circuit breaker EBU10-T

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Domae. The right solution for distribution boards

New DX 3 High rating & breaking capacity

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

DPX Magnetic only

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

Cat N 3. OVERALL DIMENSIONS

ECET Distribution System Protection. Overcurrent Protection

Electrical Safety in Die Casting

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

QUALITY ASSURANCE & DOCUMENTATION

cor Long Run Experience

PD-Series Ground Fault Circuit Protection

and other modular devices for low voltage installation

P.1 CONTENTS. Industrial Earth Leakage Protection. Page

Working Principle of Earth Leakage Circuit Breaker (ELCB) and Residual Current Device (RCD)

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Semiconductor (AC) fuses

Technical guide Protection against earth faults with Residual Current Devices

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka)

DPX 630 Electronic release

DPX Electronic + earth leakage

RX 3 M.C.B A up to 63 A

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

ब जल स स रक ष ELECTRICAL SAFETY. Dr. H. K. Verma Distinguished Professor (EEE) Sharda University, Greater Noida

SD Series Non-Fused Load Switches

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

3 - Protection components Motor circuit-breakers

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

DPX 1600 Electronic release

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

R.C.B.O. SP / 1 module

DX³ RCBO 6000 A Phase + Neutral, neutral right side

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

NXPLUS C Single busbar. Maintenance-free for lifetime

Low Voltage A GE Power Controls Company. General catalogue

Jtec 10kA Miniature Circuit Breaker

Essential equipment for all your requirements

ELECTRICAL. 60 Minutes


Electrical Safety. Recognizing & Controlling Hazards

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

The need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where uninterrupted

RX 3 M.C.B A up to 63 A

DZ47LE C45LE Residual Current Circuit Breaker with Over Current Protection

ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

ELD Earth Leakage Protection Relay

The effective choice The benefits of a product with the highest quality standards

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

An average of one worker is electrocuted on the job every day There are four main types of electrical injuries:

Technical Journal September 2012

Transcription:

Quality Features Mid Trip - Different knob position to indicate whether the device is Switched OFF by a fault or Switched OFF manually Inscription Window - Ensures circuit identification and hence reduces maintenance downtime Safety Terminals - They guide the cable towards the cage terminal and avoid improper cable termination Dual Termination - Two types of busbars can be used, that is, Fork Type and Pin Type Large Cable Terminals The terminals are suitable for cables up to 35mm 2 cross section area. Thus making it suitable for copper and aluminium cables Bi Stable Clip - Every device is provided with a dual position DIN rail clamp. Hence, a device can be easily changed from a bank of devices connected by a busbar without disturbing your existing wiring Positive Contact Indication - It clearly indicates contact position through Flag Indication (Red-ON, Green-OFF) thus enhancing safety Field fittable Auxiliary Contacts (up to 63 A) Advance Neutral - where neutral makes ahead of phases and breaks after phases, which ensures complete discharge of line inductance and capacitance, hence making it suitable as main switch. Test button for regular inspection/testing General Characteristics Crabtree introduces the new XPRO range of RCCBs rating from 16 A to 100 A. The range offers a variety of feature benefits such as Conditional Short Circuit Breaking Capacity of 10 ka across the entire range of RCCBs in accordance with IS 12640-1 & IEC 61008, it also incorporates features like Mid Trip - Different knob position to indicate whether the device is switched OFF by a fault or switched OFF manually, Inscription Window, Safety Terminals, Dual Termination, Large Cable Terminals, Bi Stable Clip, Positive Contact Indication, Field fittable Auxiliary Contacts, Test Button for Regular Inspection.

Reference Standard IS 12640-1 ; IEC 61008 No. of Poles 2P, 4P Rated Current (In) 16, 25, 32, 40, 63 A 240/415 Vac Rated Frequency (f) 50 Hz Rated Conditional Short Circuit Current (Inc) 10 ka Rated Residual Operating Current (I n) 30, 100 & 300 ma Rated Making Breaking Capacity (Im) 500 A or 10In whichever is greater Operating Characteristics in presence of Residual Current with A Type & AC Type d.c. components Trip Time 1I n < 300ms, 5I n < 40ms Rated Insulation Voltage (Ui) 690 V Rated Impulse Voltage (Uimp) 4 kv Dielectric Strength 2.5 kv Electrical / Mechanical Endurance (no. of operations) minimum 2000 / 3000 Operating Temperature -25 C to + 55 C Humidity 95% RH PROTECTION AGAINST ELECTRICAL SHOCK The use of exposed, substandard, badly wired, wrongly connected or damaged equipment as well as frayed or badly repaired cables reduces the safety of an installation and increases the risk of person receiving an electric shock. Electrocution is a passage of current through human body, which is dangerous. The flow of current through human body effects vital functions such as: 1. Breathing 2. Heartbeat A correctly chosen RCCB can detect small currents flowing to earth and reduces the risk of electrocution. Effect of electric current through human body has been well researched and following chart summarizes the results: 500 ma Immediate cardiac arrest resulting in death 70-100 ma Cardiac fibrillation; the heart begins to vibrate and no longer beats at a steady rate. This situation is dangerous since it is irreversible 20-30 ma Muscle contraction can cause respiratory paralysis 10 ma Muscle contraction : the person remains stuck to the conductor 1-10 ma Prickling sensations Terminal Capacity (max) 35 mm 2 Tightening Torque 2 N-m Vibration 3 g Shock Resistance 40mm free fall Protection Class IP 20 Positive Contact Indication Yes,Through Flag Indication (Red-ON, Green-OFF) Net Weight in kg 0.215 kg (for 2P) ; 0.335 kg (for 4P) Dimensions (H x D x W) 87.5 x 62 x 35.9 mm (for 2P) ; 87.5 x 62 x 71.8 mm (for 4P) Clip on DIN Rail (35 mm x 7.5 mm) Installation Position Vertical / Horizontal Case & Cover Moulded, flame retardant thermoplastic material Busbar Connections Top Side Busbar Connections Bottom Side Auxiliary Contacts Yes However, electrical shock should not be viewed in terms of current alone, but in terms of contact voltage. A person gets electrocuted by coming in contact with an object that has a different potential from his/her own. The difference in potential causes the current to flow through the body. The human body has known limits: AGAINST INDIRECT CONTACT Maximum Earth Fault Loop Impedances Rated res. op. current I n - 5 C 25 V Over current protection devices like MCB are unable to act promptly on small earth leakage currents. To comply with wiring regulations, the earth fault loop impedance in Ohms, multiplied by the rated tripping current of the RCD in amperes must not exceed 50. Example For an RCD with a rated tripping current of 30mA, the maximum permissible earth fault loop impedance is calculated as follows: Zs (max) = 50 / In = 50/0.03 = 1,666-5 C 50 V 0.03 A 830 1660 0.10 A 250 500 0.30 A 83 166 0.50 A 50 100

AGAINST FIRE The majority of fires which occur as a result of faulty wiring are started by current flowing to earth. Fire can be started by fault current of less than 1 amp. The normal domestic overload protective device such as a fuse or MCB will not detect such a small current. A correctly chosen RCD will detect this fault current and interrupt the supply, hence, reducing the risk of a fire starting. RESET FUNCTION The switch mechanism of RCCBs in XPRO range provides a reset function. The position of the switch lever indicates whether the RCCB has been switched off manually (position O) or as the result of a fault (central position). In order to cancel the central positioning the switch needs first to be moved to position O, only then can the RCCB be switched on again. WORKING PRINCIPLE Residual current circuit breaker (abbr. RCCB) continuously establish the total of the momentary values of all currents flowing via the active conductors to an electrical installations operated by an earthed AC mains supply. According to Kirchhoff s first law, this total must always be zero. In the event of a short-to-earth due to defective insulation, such currents will not total zero, because depending upon the fault resistance RF and the ground circuit resistance RA a residual current, also called fault current, will not flow via the active conductors but return via the earth to the power supply. If the r.m.s. value of the residual current exceeds the rated residual operating current In of the RCCB, then the latter will trigger the disconnection of the installation from the power supply. ON RESET RCCB Protection at Direct Contact RCCB Protection at Indirect Contact RCD L1 L2 L3 N OFF R M Resistance of the human body Fault resistance earthing resistance ON POSITION MID POSITION OFF POSITION Operations earth R St Resistance at site actual contact voltage residual (fault) current rated residual operating current permissible contact voltage WIRING DIAGRAM For Single Phase - 2 Wire connections For Three Phase - 4 Wire connections For Three Phase - 3 Wire connections ACTUATION TIME CHARACTERISTICS Response time of a non-delayed RCCB as a function of the magnitude of residual current. Load Load Load 500 300 Time (in ms) 150 40 The Crabtree range of four pole RCCBs can be used to provide residual current protection in 3 phase, 3 wire circuits (no neutral), however a link from the neutral to an incoming should be made on the supply side of the RCCB, to enable the operation of the RCCB. 0 0.5 1 2 5 10 20 50 I n (ma) Residual Current Multiple of I n (ma)

RCCB - STANDARD APPLICATIONS SELECTION 30 ma A 30 ma ELCB will provide a high degree of protection against electrocution in an accidental shock hazard situation. The current flowing through human body could be between 80mA and 240mA depending on the resistance of the human body and the voltage across it. are not sinusoidal. They are particularly suitable for the following specific applications (dedicated lines) or circuits that may produce DC fault currents, eg variable speed drives with frequency inverters, etc. 50.8 42 92.8 87.5 45 71.8 5.3 35.9 44 62 71.7 Zone Physiological Effects Zone 1 Usually no reactions Zone 2 Usually no harmful physiological effects Zone 3 Usually no organic damage to be expected. Likelihood of muscular contraction and difficulty in breathing, reversible disturbances of formation and conduction of impulse in the heart and transient cardiac arrest without cardiac fibrillation increases with current magnitude and time. Zone 4 ACCESSORIES Auxiliary Contact Attachment used for Signalling, Indication, Annunciation and Interlocking. Standard Conformity IS/IEC 60947-1 Current Carring Capacity (Max) 6 A 240 Vac Contact Configuration 1 NO + 1 NC Utilization Category AC 11 Electrical Endurance (No. of operations) 10000 Terminal Capacity (Max) 6 mm 2 Protection Class IP 20 as per IEC-60529/IS-2147 Left side of RCCB (Field Fittable) Contact Configuration 1NO + 1NC Current 6 A In addition to the effects of Zone 3, probability if cardiac fibrillation increased upto 5% (curve C2) upto 50% (curve C3) and above 50% beyond curve C3. It increases with magnitude and time, and pathophysiological effects such as cardiac arrest, breathing arrest and heavy burns may occur. To be within zone of the IEC curve as shown below. It is necessary for the ELCB to operate within 50ms at 240 ma and 150ms at 80mA. Both these conditions are satisfied by 30mA ELCB. For households, individual outlets, wet areas and temporary installations, ELCB with sensitivity not exceeding 30mA is advisable. 11.3 11.3 8.85 8.85 62.0 44.0 1.4 100 ma A 100mA ELCB will normally give high degree of protection against electrocution but there is a possibility that the shock current could fall below the tripping level of ELCB. This could occur if additional resistances to that of human body are included in the earth path. The 100mA RCCB protects against leakage currents and indirect contact with earth loop impedance upto 500 Ohms. 16.5 16.5 45.0 87.5 300 / 500mA A 300/500 ma ELCB may be used where only fire protection is required. eg., on lighting circuits, where the risk of electric shock is small. 300/500mA ELCB will not give any protection against electrocution. S-TYPE AUX H-TYPE AUX 2.4 69.8

(80A-100A) Reference Standard IS 12640-1 ; IEC 61008 No. of Poles 2P, 4P Rated Current (In) 80, 100 A 240/415 Vac Rated Frequency (f) 50 Hz Rated Conditional Short Circuit Current (Inc) 10 ka Rated Residual Operating Current (I n) 30, 100 & 300 ma Rated Making Breaking Capacity (Im) 10In Operating Characteristics in presence of Residual Current with A Type & AC Type d.c. components Trip Time 1I n < 300ms, 5I n < 40ms Rated Insulation Voltage (Ui) 690 V Rated Impulse Voltage (Uimp) 4 kv Dielectric Strength 2.5 kv Electrical / Mechanical Endurance (no. of operations) minimum 2000 / 3000 Operating Temperature -25 C to + 55 C Humidity 95% RH Terminal Capacity (max) 50 mm 2 Tightening Torque 2.5 N-m Vibration 3 g Shock Resistance 40mm free fall Protection Class IP 20 Positive Contact Indication Yes,Through Flag Indication (Red-ON, Green-OFF) Net Weight in kg 0.230 kg (for 2P) ; 0.404 kg (for 4P) Dimensions (H x D x W) in mm 88.2 x 62 x 35.9 mm (for 2P) ; 88.2 x 62 x 71.8 mm (for 4P) Clip on DIN Rail (35 mm x 7.5 mm) Installation Position Vertical / Horizontal Case & Cover Moulded, flame retardant thermoplastic material Busbar Connections Top Side Busbar Connections Bottom Side Auxiliary Contacts No WIRING DIAGRAM For Single Phase - 2 Wire connections For Three Phase - 4 Wire connections For Three Phase - 3 Wire connections Load Load Load The Crabtree range of four pole RCCBs can be used to provide residual current protection in 3 phase, 3 wire circuits (no neutral), however a link from the neutral to an incoming should be made on the supply side of the RCCB, to enable the operation of the RCCB. 88.25 88.25 36.0 71.7 45.0 72.0 36.0 62.0 44.0