AR No. # Low Pressure Irrigation

Similar documents
AR No. # - Install (Belt Type Here)

Pump ED 101. Variable, Fixed Speed Control - - Float Switch Activation. Introduction

ENERGY CONSERVATION USING VARIABLE-FREQUENCY DRIVES FOR CENTER PIVOT IRRIGATION

MOTOR SAMPLE PROBLEM #1 Low-Slip Drive Belts

Save Thousands of Dollars Per Year!

MOTOR SURVEY. Solutions for Industry

Modeling a Sprinkler System or a System With Nozzles

Assessing Your Sprinkler Irrigation System

DT34/DT54 SERIES GOLF ROTORS

EQUAL DISTRIBUTION OF WASTEWATER USING LOW-PRESSURE DISTRIBUTION Larry D. Stephens, P.E. *

PROFITS.WATER.AND ENERGY. Blaine R. Hansonl

Level 7 Post Graduate Diploma in Engineering Power System Economics and Planning

SERVICE THE GORMAN-RUPP COMPANY P.O. Box 1217 MANSFIELD, OH FX

Handout Homework page 1 of 6. JEE 4360 Energy Alternatives Handout (HO) Homework Problems

Horsepower to Drive a Pump

Spray and Rotary Nozzles

Working through the electric motor replacement maze

Spray and Rotary Nozzles

Water System Sizing Worksheet. Joe Agricola Example

Pump Control Ball Valve for Energy Savings

835S/855S SERIES GOLF ROTORS

Washtenaw County DESIGN PROCEDURES AND ENGINEERING STANDARDS FOR PRESSURE DISTRIBUTION NETWORKS

Example 1MW Solar System for Fosters Yatala

800S Series. Based on proven technology. When creating the 800S Series. sprinkler, we started with. technology that works. Then

Wind Powered Electric Energy Generation Small Generator Economics

CHAPTER 4 MODELING OF PERMANENT MAGNET SYNCHRONOUS GENERATOR BASED WIND ENERGY CONVERSION SYSTEM

Grid Services From Plug-In Hybrid Electric Vehicles: A Key To Economic Viability?

Distribution Uniformity of Multi Stream Multi Trajectory Rotary Nozzles Spaced Below Recommended Distance

FLEX800 35/55 SERIES GOLF ROTORS

BIODIESEL. Lesson 4d Test biodiesel in a diesel generator. Developed by Engineering and Technology Curriculum Team

FLEX /55-6 SERIES GOLF ROTORS

Machine Drive Electricity Use in the Industrial Sector

How vehicle fuel economy improvements can save $2 trillion and help fund a long-term transition to plug-in vehicles

Measuring Pump Efficiency with Mike Eglitis

Modern Pump Selection for System Efficiency. By: Kyle DelPiano - Business Development Manager, Bell & Gossett

MRC Field Trial Performance Report (Hugoton Deep Reservoir in Kansas) Revision 1.9

Generator Efficiency Optimization at Remote Sites

Components of Hydronic Systems

Executive Summary. Solid Waste Management Program Analysis and Recommendations for Silver City, New Mexico

SPRING CENTER PIVOT AND LATERAL

EVSE Impact on Facility Energy Use and Costs

Common recommendations

Biofuel sustainability The issue of indirect land use change (ILUC)

NELSON. BUILT STRONGER TO LAST LONGER! Large impact surfaces for consistent long life drive. Sturdy Drive Arm

Fueling Savings: Higher Fuel Economy Standards Result In Big Savings for Consumers

570Z Series. Reliability is simply stated in. 570Z Series 20 years of solid. performance. Add to that its. extensive product line offering and

Best Practice Variable Speed Pump Systems

INFINITY 34/54 SERIES ROTORS

In order to discuss powerplants in any depth, it is essential to understand the concepts of POWER and TORQUE.

Optimizing Airflow on Dust, Mist and Fume Collection Systems

Hydraulics Guide. Table 1: Conveyance Factors (English Units)... 7 Table 2: Conveyance Factors (Metric Units)... 8

Center for Irrigation Technology

FIELD-TESTED FIELD-PROVEN. field-proven technology. Water Application Solutions for Agricultural Irrigation. Product Update 01/11

Pepco & Delmarva Power. Commercial & Industrial Energy Savings Program Grocery and Convenience Stores October 11, 2012

Impact Evaluation of 2004 Compressed Air Prescriptive Rebates

STUDENTS DO NOT OPEN THIS TEST OR BEGIN UNTIL INSTRUCTED TO Examination for the. Read the following instructions:

i-wob com www. MECHANIZED IRRIGATION

Energy Savings and Incentives with PG&E. Chad Stout Account Manager

Appendix G - Danvers Electric

Spacing and Pattern Effects on DU LQ of Spray Nozzles

BRIGGS IRRIGATION Operators Manual & Parts Manual R40 Hosereel Mounted Boom Irrigator

Efficiency Works Business

WATER SYSTEM SIZING Introduction Residential Water System Sizing

BEFORE THE PUBLIC UTILITY COMMISSION OF OREGON PACIFICORP. Exhibit Accompanying Direct Testimony of Judith M. Ridenour

UNIFORMITY CHARTS Accompanied with Precipitation Rates

Appendix E Water Supply Modeling

I-WOB The Most Imitated Sprinkler on the Market

Cooling Efficiency 2017 Cooling Equipment Rebate Application

CHAPTER 1 INTRODUCTION

PROCESS VFD SAVINGS CALCULATOR USER GUIDE CONTENTS ENERGY EFFICIENCY FOR BUSINESS CUSTOM INCENTIVES CUSTOM-TO-GO

ENERGY STORAGE. resource guide & user instructions

NOTICE OF TOTALIZING FLOW METER RE-VERIFICATION, INSTALLATION OR REPLACEMENT

Beyond Net Metering Issues for Washington State

Mechanized Irrigation

Golf sprinklers with all the efficiency and proven performance features and benefits of the 800S and DT Series FLEX800 SERIES ROTORS

590G Series Golf Spray Head. 590G Series Golf Spray Head. Variable Arc 4, 6, 12 Pop-up X-Flow and Check-O-Matic Standard.

About Control Systems

Precision Cooling For Business-Critical Continuity. Liebert CW. System Design Manual kW, 50 & 60Hz

Cordova Psychrophiles Bio-Digester. Benefit-Cost and Sensitivity Analysis

Electricity Rates. effective May 1, For residential customers

The Energy Independence and Security Act (EISA): Proposed Changes to the Renewable Fuel Standard Program (RFS2)

Future Funding The sustainability of current transport revenue tools model and report November 2014

PV-Wind SOFTWARE for Windows User s Guide

William Piel

Unitil Energy Demand Response Demonstration Project Proposal October 12, 2016

Electric Utility Incentive Programs. Marcus Wilcox, President Cascade Energy, Inc.

Super Spray. com. www. Mechanized irrigation

Irrigation Uniformity

21 Keep Residential Stairwells & Hallways Lit During Blackouts

Vanadium Battery Initial Test Results

Energy Savings Variable Frequency Drives and Cooling Tower Fan Motors

The Economics of Dimming. Technical white paper Dr. Ian Rowbottom May 26, 2010

Super Spray. com. www. Mechanized irrigation

APPENDIX 1 TECHNICAL DATA OF TEST ENGINE

IMPROVING MOTOR SYSTEM EFFICIENCY WITH HIGH EFFICIENCY BELT DRIVE SYSTEMS

Community Solar FAQ. How does the Community Solar program work?

TAPE EXTENSOMETER Model CONVEX-D. Roctest Limited, All rights reserved.

ENERGY & UTILITIES. Electricity Metering & Sub-Metering Concepts and Applications. BuildingsOne April 30, 2018

You have probably noticed that there are several camps

Long-Term Costs and Savings of Properly Rewound Motors

Transcription:

AR No. # Low Pressure Irrigation Recommendation Install a variable speed drive (VSD) on the 25 hp submersible pump. This will allow the system to operate at a lower pressure, delivering the same water with less energy than the current method and reduce total pump operating cost by 58.6%. Assessment Recommendation Summary Energy Energy Cost Implementation Payback (MMBtu)* (kwh)* Savings Cost (Years) 23.7 6,940 $484 $5,230 10.8 * 1 MMBtu = 1,000,000 Btu, 1 kwh = 3,413 Btu Background The 25 hp irrigation system features a single 30 foot deep submersible pump operating to serve one of two similarly sized pivots at a given time, resulting in very little demand variation. The system utilizes low pressure drop down nozzles to deliver water to the field yet the pump runs at relatively high pressures. This is not an efficient method to deliver water to a field. This pump is on its own dedicated electrical service. Variable speed drives (VSD), are able to change how a pump operates based on an adjustable parameter such as pressure, resulting in significant energy and demand savings. The VSD will also soft start the motor by slowly ramping it up to full speed instead of doing it instantaneously. Variable speed drives and low pressure irrigation have many benefits besides reduced energy costs: Reduced Maintenance Costs - A soft start will also reduce motor wear and damage caused by hard starting as well as maintenance costs associated with water hammer, sprinkler head damage, and flexible coupling damage extending the expected life of the system. Increased Yields - Low pressure drop down nozzles result in a more uniform distribution of water on the field. This reduces under or over irrigated sections, increasing yields. Water Conservation - Low pressure drop down nozzles reduce wind drift and evaporation losses usually associated with conventional methods of irrigation. This increases the amount of water delivered to the fields, reducing irrigation times. Motor Protection - VSD's help reduce the effects of voltage swings in the power distribution system due to other systems kicking on or off. VSD's can maintain full output voltage at full load, with voltage sags as low as 15 percent helping to protect the motor.

Proposal We recommend installing a Variable Speed Drive controlled by a pressure sensor on the 25 hp submersible river pump motor. This will allow system operation at a lower pressure while maintaining the current flow rate. The VSD will also allow soft starting of the pump resulting in reduced lower maintenance costs (not included in our estimates). If the previously mentioned actions are taken, they will save 6,940 kwh annually and result in an annual cost savings of $484. Take advantage of the included incentive programs for a net payback of 10.8 years with an implementation cost of $5,230. Source: http://www.flickr.com/photos/29385617@n00/ Notes Based on annual pump electrical draw, delivered flow, and a calculated average pump head; the pump is delivering needed water at a 49.9% average system efficiency. According to the Hydraulics Institute Standard ANSI/HI-1.3, the modeled average flow and head delivered to the irrigation system can be developed up to an optimum efficiency of 71.5%. This low efficiency could be caused by the pump operating off of its Best Efficiency Point (BEP) or by pump degradation. We recommend having a pump specialist inspect the pump to determine if repair or replacement is needed. Doing so could reduce associated energy consumption by 3,580 kwh resulting in an additional $250 annual cost savings. These savings are not included in this recommendation. VSD savings associated with varying end gun use are not included in this calculation, which could yield increased savings. The end gun nozzle size may have to be replaced from the current 0.55" to a 0.7" diameter in order to provide the desired flow and range. This cost is negligible and therefore not included in the calculation.

Our analysis assumes pump efficiency will not change significantly when its operation moves to a new point on its performance curve with VSD control and reduced system pressure. An alternative solution is to install a pump specifically designed to operate at the current flow conditions. This would be beneficial as both savings mentioned above would be obtained for a total annual savings of $734 and 10,520 kwh, however, we did not recommend this because the lack of adjustability and fine tuning available if the system end use ever changes. This system would however not be as able to adjust to varying end uses such as elevation change or end gun operation. Author Readability Review Engineering Review Math Review Mikhail Jones Carl Moen Joe Piacenza Joe Piacenza

Low Pressure Irrigation Data Collected Equations Pump System Eq. 1) Mainline Pressure Loss (P L1 ) Current Max Demand (ED C ) 20.7 kw (N. 1) 1.852 Pump Horsepower (HP) 25 100 1.852 hp (N. 2) L 0.2083 Q CF1 Current Pivot Pressure (P C1 ) 66.0 psi (N. 2) CA 100 4.8655 D Mainline System Flow Rate (Q) 300 gpm (N. 2) Eq. 2) Current Pump Pressure (P C2 ) Mainline Diameter (D) 6.4 inches (N. 2) PC1 PL 1 Mainline Length (L) 1,100 feet (N. 2) Energy Consumption Eq. 3) Proposed Pump Pressure (P P2 ) Current Energy Consumption (EC C ) 11,852 kwh (Rf. 1) P 1 PL 1 Incremental Costs Incremental Electricity Cost (EC) $0.06969 $/kwh (Rf. 1) Eq. 4) Proposed Energy Consumption (EC P ) P 2 Assumptions ECC Material Properties PC 2 Hazen-Williams Coefficient (Al) (C A ) 140 (N. 3) Eq. 5) Energy Savings (ES) Conversion Factors Pressure Conversion Factor (CF 1 ) 0.43353 psi/fth 2 O ECC ECP Eq. 6) Cost Savings (CS) Pressure Development Pressure Losses/Gains Mainline Pressure Loss (P L1 ) 2.5 psi (Eq. 1) ES EC Eq. 7) Implementation Cost (IC) Pressures CM1 CM 2 CL 1 Current Pump Pressure (P C2 ) 68.5 psi (Eq. 2) Proposed Pivot Pressure (P P1 ) 25.9 psi (Rf. 2) Proposed Pump Pressure (P P2 ) 28.4 psi (Eq. 3) References Energy Savings Summary Proposed Energy Consumption (EC P ) 4,910 kwh (Eq. 4) Energy Savings (ES) 6,942 kwh (Eq. 5) Rf. 1) Annual energy data according to utility bills. Rf. 2) Pivot irrigation system pressure loss development tables at end of recommendation. Implementation Costs Summary Variable Speed Drive Variable Speed Drive (C M1 ) $2,330 (Rf. 3) Rf. 3) Vendor supplied guidelines for estimating the variable speed drive and associated installation costs. Manual Bypass and Circuit Breaker (C M2 ) $1,900 (Rf. 3) Installation and Setup (C L1 ) $1,000 (Rf. 3) Notes N. 1) Live power was determined on site by Economic Results Cost Savings (CS) $484 (Eq. 6) collecting the amount of energy consumed at the meter over one hour. Implementation Costs (IC) $5,230 (Eq. 7) N. 2) Data was provided by site personnel. Payback (PB) 10.8 years N. 3) Hazen-Williams Coefficient for Aluminum.

Span 3 Span 2 Span 1 Current Pivot Conditions Sprinkler Nozzle Pressure Flow No. Location Separation Model Plate Model Reg. In Reg. Out Losses Required Delivered Available (#) (feet) (feet) (psi) (psi) (psi) (gpm) (gpm) (gpm) 1 33.7 33.7 R3000 Red #14 65.9 20.0 0.07 1.38 1.49 298.5 2 51.5 17.8 R3000 Red #14 65.9 20.0 0.04 1.11 1.49 297.0 3 68.7 17.2 R3000 Red #14 65.8 20.0 0.04 1.43 1.49 295.5 4 85.9 17.2 R3000 Red #15 65.8 20.0 0.04 1.79 1.74 293.8 5 103.3 17.4 R3000 Red #16 65.8 20.0 0.04 2.18 1.98 291.8 6 120.5 17.2 R3000 Red #18 65.7 20.0 0.04 2.52 2.48 289.3 7 138.0 17.5 R3000 Red #19 65.7 20.0 0.04 2.93 2.79 286.5 8 155.8 17.8 R3000 Red #20 65.7 20.0 0.04 3.37 3.1 283.4 9 173.6 17.8 R3000 Red #23 65.6 20.0 0.03 3.75 4.05 279.4 10 193.5 19.9 R3000 Red #23 65.6 20.0 0.04 4.67 4.05 275.3 11 211.3 17.8 R3000 Red #24 65.6 20.0 0.03 4.57 4.46 270.9 12 229.1 17.8 R3000 Red #25 65.5 20.0 0.03 4.95 4.82 266.1 13 246.3 17.2 R3000 Red #25 65.5 20.0 0.03 5.14 4.82 261.2 14 263.5 17.2 R3000 Red #27 65.5 20.0 0.03 5.50 5.61 255.6 15 280.9 17.4 R3000 Red #27 65.4 20.0 0.03 5.93 5.61 250.0 16 298.1 17.2 R3000 Red #28 65.4 20.0 0.03 6.22 6.11 243.9 17 315.6 17.5 R3000 Red #29 65.4 20.0 0.03 6.71 6.53 237.4 18 333.4 17.8 R3000 Red #30 65.4 20.0 0.02 7.20 6.99 230.4 19 351.2 17.8 R3000 Red #28 65.3 20.0 0.02 7.59 6.11 224.3 20 362.2 11.0 R3000 Red #23 65.3 20.0 0.01 4.84 4.05 220.2 21 371.1 8.9 R3000 Red #23 65.3 20.0 0.01 4.01 4.05 216.2 22 380.0 8.9 R3000 Red #23 65.3 20.0 0.01 4.11 4.05 212.1 23 388.9 8.9 R3000 Red #23 65.3 20.0 0.01 4.20 4.05 208.1 24 397.8 8.9 R3000 Red #23 65.3 20.0 0.01 4.30 4.05 204.0 25 406.7 8.9 R3000 Red #23 65.3 20.0 0.01 4.39 4.05 200.0 26 415.3 8.6 R3000 Red #24 65.3 20.0 0.01 4.34 4.46 195.5 27 423.9 8.6 R3000 Red #23 65.3 20.0 0.01 4.43 4.05 191.5 28 432.5 8.6 R3000 Red #24 65.3 20.0 0.01 4.52 4.46 187.0 29 441.1 8.6 R3000 Red #24 65.2 20.0 0.01 4.61 4.46 182.6 30 449.9 8.8 R3000 Red #24 65.2 20.0 0.01 4.81 4.46 178.1 31 458.5 8.6 R3000 Red #25 65.2 20.0 0.01 4.79 4.82 173.3 32 467.1 8.6 R3000 Red #25 65.2 20.0 0.01 4.88 4.82 168.5 33 475.7 8.6 R3000 Red #25 65.2 20.0 0.01 4.97 4.82 163.6 34 484.3 8.6 R3000 Red #25 65.2 20.0 0.01 5.06 4.82 158.8 35 493.2 8.9 R3000 Red #26 65.2 20.0 0.01 5.33 5.23 153.6 36 502.1 8.9 R3000 Red #26 65.2 20.0 0.01 5.43 5.23 148.4 37 511.0 8.9 R3000 Red #26 65.2 20.0 0.01 5.52 5.23 143.1 38 519.9 8.9 R3000 Red #27 65.2 20.0 0.00 5.62 5.61 137.5 39 528.8 8.9 R3000 Red #30 65.2 20.0 0.00 5.71 6.99 130.5

Overhang 40 542.0 13.2 R3000 Red #31 65.2 20.0 0.01 8.69 7.4 123.1 41 552.0 10.0 R3000 Red #29 65.2 20.0 0.00 6.70 6.53 116.6 42 562.0 10.0 R3000 Red #29 65.2 20.0 0.00 6.82 6.53 110.1 43 572.0 10.0 R3000 Red #30 65.2 20.0 0.00 6.94 6.99 103.1 44 582.0 10.0 R3000 Red #30 65.2 20.0 0.00 7.07 6.99 96.1 45 592.0 10.0 R3000 Red #30 65.2 20.0 0.00 7.19 6.99 89.1 46 602.0 10.0 R3000 Red #34 65.2 20.0 0.00 7.31 9.01 80.1 Booster Pump/End Gun Sprinkler Nozzle Pressure Flow Range No. Location Model Diameter Booster In Booster Booster Out Available Delivered Required Radius (#) (feet) (inches) (psi) (psi) (psi) (gpm) (gpm) (gpm) (feet) 80 607 SR100T 0.55" 65.2 0.0 65.2 80.1 69.0 70.7 113.5

Span 3 Span 2 Span 1 Proposed Pivot Conditions Sprinkler Nozzle Pressure Flow No. Location Separation Model Plate Model Reg. In Reg. Out Losses Required Delivered Available (#) (feet) (feet) (psi) (psi) (psi) (gpm) (gpm) (gpm) 1 33.7 33.7 R3000 Red #14 25.8 20.0 0.07 1.38 1.49 298.5 2 51.5 17.8 R3000 Red #14 25.8 20.0 0.04 1.11 1.49 297.0 3 68.7 17.2 R3000 Red #14 25.7 20.0 0.04 1.43 1.49 295.5 4 85.9 17.2 R3000 Red #15 25.7 20.0 0.04 1.79 1.74 293.8 5 103.3 17.4 R3000 Red #16 25.7 20.0 0.04 2.18 1.98 291.8 6 120.5 17.2 R3000 Red #18 25.6 20.0 0.04 2.52 2.48 289.3 7 138.0 17.5 R3000 Red #19 25.6 20.0 0.04 2.93 2.79 286.5 8 155.8 17.8 R3000 Red #20 25.6 20.0 0.04 3.37 3.1 283.4 9 173.6 17.8 R3000 Red #23 25.5 20.0 0.03 3.75 4.05 279.4 10 193.5 19.9 R3000 Red #23 25.5 20.0 0.04 4.67 4.05 275.3 11 211.3 17.8 R3000 Red #24 25.5 20.0 0.03 4.57 4.46 270.9 12 229.1 17.8 R3000 Red #25 25.4 20.0 0.03 4.95 4.82 266.1 13 246.3 17.2 R3000 Red #25 25.4 20.0 0.03 5.14 4.82 261.2 14 263.5 17.2 R3000 Red #27 25.4 20.0 0.03 5.50 5.61 255.6 15 280.9 17.4 R3000 Red #27 25.3 20.0 0.03 5.93 5.61 250.0 16 298.1 17.2 R3000 Red #28 25.3 20.0 0.03 6.22 6.11 243.9 17 315.6 17.5 R3000 Red #29 25.3 20.0 0.03 6.71 6.53 237.4 18 333.4 17.8 R3000 Red #30 25.3 20.0 0.02 7.20 6.99 230.4 19 351.2 17.8 R3000 Red #28 25.2 20.0 0.02 7.59 6.11 224.3 20 362.2 11.0 R3000 Red #23 25.2 20.0 0.01 4.84 4.05 220.2 21 371.1 8.9 R3000 Red #23 25.2 20.0 0.01 4.01 4.05 216.2 22 380.0 8.9 R3000 Red #23 25.2 20.0 0.01 4.11 4.05 212.1 23 388.9 8.9 R3000 Red #23 25.2 20.0 0.01 4.20 4.05 208.1 24 397.8 8.9 R3000 Red #23 25.2 20.0 0.01 4.30 4.05 204.0 25 406.7 8.9 R3000 Red #23 25.2 20.0 0.01 4.39 4.05 200.0 26 415.3 8.6 R3000 Red #24 25.2 20.0 0.01 4.34 4.46 195.5 27 423.9 8.6 R3000 Red #23 25.2 20.0 0.01 4.43 4.05 191.5 28 432.5 8.6 R3000 Red #24 25.2 20.0 0.01 4.52 4.46 187.0 29 441.1 8.6 R3000 Red #24 25.1 20.0 0.01 4.61 4.46 182.6 30 449.9 8.8 R3000 Red #24 25.1 20.0 0.01 4.81 4.46 178.1 31 458.5 8.6 R3000 Red #25 25.1 20.0 0.01 4.79 4.82 173.3 32 467.1 8.6 R3000 Red #25 25.1 20.0 0.01 4.88 4.82 168.5 33 475.7 8.6 R3000 Red #25 25.1 20.0 0.01 4.97 4.82 163.6 34 484.3 8.6 R3000 Red #25 25.1 20.0 0.01 5.06 4.82 158.8 35 493.2 8.9 R3000 Red #26 25.1 20.0 0.01 5.33 5.23 153.6 36 502.1 8.9 R3000 Red #26 25.1 20.0 0.01 5.43 5.23 148.4 37 511.0 8.9 R3000 Red #26 25.1 20.0 0.01 5.52 5.23 143.1 38 519.9 8.9 R3000 Red #27 25.1 20.0 0.00 5.62 5.61 137.5 39 528.8 8.9 R3000 Red #30 25.1 20.0 0.00 5.71 6.99 130.5

Overhang 40 542.0 13.2 R3000 Red #31 25.1 20.0 0.01 8.69 7.4 123.1 41 552.0 10.0 R3000 Red #29 25.1 20.0 0.00 6.70 6.53 116.6 42 562.0 10.0 R3000 Red #29 25.1 20.0 0.00 6.82 6.53 110.1 43 572.0 10.0 R3000 Red #30 25.1 20.0 0.00 6.94 6.99 103.1 44 582.0 10.0 R3000 Red #30 25.1 20.0 0.00 7.07 6.99 96.1 45 592.0 10.0 R3000 Red #30 25.1 20.0 0.00 7.19 6.99 89.1 46 602.0 10.0 R3000 Red #34 25.1 20.0 0.00 7.31 9.01 80.1 Booster Pump/End Gun Sprinkler Nozzle Pressure Flow Range No. Location Model Diameter Booster In Booster Booster Out Available Delivered Required Radius (#) (feet) (inches) (psi) (psi) (psi) (gpm) (gpm) (gpm) (feet) 80 607 SR75 0.7" 25.1 0.0 25.1 80.1 69.0 70.7 83.5