EDGE EV3WW 3 Recessed Linear Wall Wash

Similar documents
Project Name. 4-1/4 (107.9mm) or 5-1/4 (133.4mm)

EDGE E4 4 Recessed Linear

EDGE ET6 6 Recessed Linear EDGE Techx for Integrated Ceiling Systems

EDGE EV6 6 Recessed Linear

Project Name ADEO AD24 EMERGENCY. G1-15/16 Grid G9-9/16 Grid GS - Screw Slot Grid FL - Flanged S - Surface Mount. Mounting pg. 3

Project Name ADEO AD22 EMERGENCY. G1-15/16 Grid G9-9/16 Grid GS - Screw Slot Grid FL - Flanged S - Surface Mount. Mounting pg. 3

EDGE EX3B-WW 3 Suspended Bidirectional Linear Wall Wash

Project Name ADEO AD14. Adeo 1x4 (AD14) 1x4 Architectural Recessed. (76.2mm) EMERGENCY

Evolution Outline RECESSED LINEAR PERIMETER OUTLINE SLOT SYSTEM

EDGE EX3 3 Suspended Direct Linear

FINA F48 48 Direct and Uplight Architectural Round

EDGE EV3WET 3 Recessed Linear WET

EDGE EV1 1 Recessed Linear

Project Name. (136.5mm) 11/16 (17.5m) _ K _ K _ K _ K CL - Custom Lumens CW - Custom Watts. Lumen Output pg.

Project Name LUCEN LU14. 1x4 Architectural Recessed EMERGENCY. G1-15/16 Grid G9-9/16 Grid GS - Screw Slot Grid FL - Flanged S - Surface Mount

FINA F36B 36 Bidirectional Architectural Round

FINA F48B 48 Direct and Uplight Architectural Round

CONVERJ CJ22 2x2 Architectural Recessed

EX3. Project Name _ K. R_x_ Rectangle. MAC JB Junction Box Movable AC

EDGE EX6WET 6 Suspended Direct Linear WET

CONVERJ CJ14 1x4 Architectural Recessed

EX3B. Project Name _ K 4000K. R_x_ Rectangle. MAC JB Junction Box Movable AC

LiFT LF12 1x2 Architectural Recessed

EDGE EX3I 3 Suspended Indirect Linear

CONVERJ CJ24 2x4 Architectural Recessed

EDGE EX44 4 x 4 Suspended Direct Linear

EDGE EX4B 4 Suspended Bidirectional Linear

COVE C CV N - - Architectural Cove Mount. Key Features CRI, CCT & OUTPUT LENGTH 1 MOUNTING VOLTAGE DRIVER CIRCUITING _ N

Project Name. 24 (609.6mm)

Project Name. 24 (609.6mm) 24 (609.6mm)

EDGE EX2 2 Direct Suspended Linear

Project Name. 23-3/4 (603.3mm)

EDGE EX3DI 3 Suspended Direct/Indirect Linear

Project Name. 23-5/8 (600.2mm)

LINERO L_6A Suspended Linear

EDGE EX1 1 Suspended Direct Linear

EDGE EX33 3 x 3 Suspended Direct Linear

LUCEN 2x2 ARCHITECTURAL RECESSED LUMINAIRE

EDGE EX1B 1 Suspended Bidirectional Linear

EDGE EV3D 3 Recessed Linear

RECESSED ASYMMETRIC MOUNT. Project. Type. Notes TECHZONE TM AND LOGIX TM COMPATIBLE

PERIMETER - RECESSED. Regressed 3" BMPRLED OPRI ( 1) 14 PRODUCT ID LINEAR OR CORNER QTY TOTAL LENGTH. 3D VIEW - Inside Corner Pattern

PERIMETER - RECESSED. Flush BBPRLED OPRI ( 1) 14 PRODUCT ID LINEAR OR CORNER QTY TOTAL LENGTH. 3D VIEW - Inside Corner Pattern

RECESSED T-BAR & DRYWALL. Project. Type. Notes. 0.5 StepLens. StepLens

RECESSED T-Bar & Drywall. Project. Type. Notes 23 15/16" 23 7/8" SIDE VIEW. culus Listed Type I.C.

Notes: 4" 102mm. (1) Compatible with Redwood systems

REGOLO 1. RP11 Direct

RECESSED - WITH StepLens OPTION. TECHZONE TM AND LOGIX TM COMPATIBLE for more info see page 4 See page 2 for DLC Approved Options

(5) For 347V only (6) Specify system (7) Please consult factory; see page 2

SURFACE MOUNTED. Project. Type. Notes. culus Listed Type I.C.

Avenue B. Grid Mount (Regress Trim Shown) Flush Lens. Drywall Flange (Regress Trim Shown) Narrow 3" slot LED with frosted satin lens.

WALL MOUNT DIRECT/INDIRECT. Project. Type. Notes

Avenue B. Narrow 3" slot LED with frosted satin lens. Shielding options include corrugated or solid regressed trim or flush lens.

DESCRIPTION PROJECT: Vega is an efficient architectural LED troffer with a distinctive luminous shielding that features a median textured

RECESSED T-Bar & Drywall. Project. Type. Notes AULED 14 SO

Tove. High Performance Linear System Recessed

RECESSED MOUNT. Outputs between listed min and max are available. Consult factory for outputs outside of the listed range.

avenue led features dimensional data performance Narrow 3" slot LED with frosted satin lens.

SURFACE ASYMMETRIC MOUNT. Project. Type. Notes

RECESSED MOUNT. 2 StepLens

RECESSED T-Bar & Drywall. Project. Type. Notes 47 15/16" 47 7/8" 48" between T-Bar SIDE VIEW

IC 4 5 YEAR RECESSED MOUNT. Project. Type. Notes 1 9/16 PERFORMANCE PER LINEAR FOOT AT 4000K CONTROL SENSORS

Project. Type. Notes. C custom UNV universal BI bi-level dimming +NL(#) night light circuit (7) O other (6) +GTD(#) generator transfer device (7)

Please consult factory for other lumen packages

RECESSED T-Bar & Drywall. Project. Type. Notes. 3 7/8" 98mm

SURFACE MOUNT. Project. Type. Notes

RECESSED ASYMMETRIC MOUNT

Skydome. 2', 3' and 4' diameter recessed direct LED with lens. Frosted acrylic diffuser provides high transmission and uniform distribution.

Tove. High Performance Linear System T-Grid Recessed

SURFACE FLUSH FLUSH 5 1 / / /4 2 1 /16

WALL MOUNT DIRECT. Project. Type. Notes

44-R-WWD. MOD 44 Recessed Wall Wash Direct. Ordering Guide. Key Features 44-R-WWD. Fixture Type: Project Name: Quick Find litecontrol.

High Performance Linear System Recessed

VIA 4 LED RECESSED W W W. L U M E N W E R X. C O M

PENDANT ASYMMETRIC MOUNT - DIRECT. Project. Type. Notes

PENDANT MOUNT - DIRECT

PENDANT MOUNT - DIRECT. Project. Type. Notes

WALL MOUNT - DIRECT/INDIRECT

DIRECT OPTIC HOUSING COLOR 4 DRIVER FEED LENGTHS

Verve IV. fixture information. Suspended linear direct/indirect LED with frosted lens or Radial Baffle options.

Type: Quantity: Project:

Project. Type. Notes 8' (96") 8' (96") ALL ORDERS MUST BE SUBMITTED WITH DRAWINGS INDICATING DIMENSIONS, ANGLES AND DIAMETER

SLOTLIGHT LED II. Type: Quantity: Project: DIRECT OPTIC HOUSING COLOR 4 DRIVER FEED LENGTHS. P Opal

L10 - L40: 5-3/4 L50 - L60: 6-1/ K K K F OF 1/2. 65 Open. CG Champagne gold anodize for shower. 45 Open

PENDANT MOUNT - DIRECT. Project. Type. Notes

LAD8R - Remodel 8 LED Architectural Downlight

Nera. detail. fixture information. Unique aesthetic inspired by the visual void design philosophy. Luminaire sizes available in 2 x2, 3 x3 and 4 x4.

CYL8 8" Integrated LED Indoor and Outdoor Cylinders

WALL LO-OUTPUT. Project. Type. Notes

Tove. High Performance Linear System Perimeter

L10 - L40: 6-5/8 L50 - L60: 7-3/ K K K F. 65 Open. SPC Clear specular anodize for shower

Avenue A. Grid Mount. Drywall Flange. lens. Narrow aperture high performance T5/T5HO asymmetric wall wash.

Avenue A. Grid Mount. Drywall Flange. lens. Narrow aperture high performance T5/T5HO asymmetric wall wash.

FINELITE 10 Year LED Warranty

2 1/2. Applies to both UP & DOWN. Specify quantity. Requires 8" blank See integrated controls guide for more details.

SURFACE MOUNT. See page 3 for DLC Approved options

Catalog # Project. Comments. Prepared by. Warranty Five year warranty.

Project. Type. Notes. (3) D dimming (0-10V) 5% standard

id + 4.5" x 4.5" Downlight mm Trim ChromaSure: Color consistency resulting in a 2-step MacAdam ellipse across the entire ID+ product line.

PENDANT ASYMMETRIC MOUNT

Transcription:

Project Name EDGE 3WW EV3WW Date Type 3 (72.6mm) EDGE EV3WW 3 5/8 (30.2mm) 7/6 /6 (.m) See Mounting Section (7.5m) Key Features Extruded aluminum trim with formed cold rolled 20 gauge steel back box housing Highly reflective, dieformed white, painted steel reflector 5year limited warranty covers LED, driver and fixture UL and cul listed. IC rated Approved for dry/damp location unless otherwise noted Maximum fixture weight is 5lbs (per 4ft fixture) RoomSide Maintenance for LED system Designed to be mounted facing wall between 2 8 from wall Buy American Act compliant EV3WW CRI, CCT & OUTPUT LENGTH MOUNTING VOLTAGE DRIVER CIRCUITING _27 2700K _30 3000K _35 3500K _40 4000K CL Custom Lumens CW Custom Watts BATTERY & FINISH EMERGENCY FIXTURE OPTIONS CRI, CCT & OUTPUT Example Part #: EV3WW830HO26 GUOL0W LENGTH MOUNTING VOLTAGE Individual Fixture Continuous Row G(G) (5/6 ) T Bar G9(G) 9/6 T Bar GB(G) 9/6 Bevel T Bar GS(G) Screw Slot T Bar FL(F) /2 Flange NF(N) Non Flange SF(S) Spackle Flange UU niversal 2 3 Length and Pattern pg. 2 Lumen Output pg. 2 Example: 830HO is 8 = 80 CRI; 30 = 3000K; HO = High Output; Blank = Standard Output (20 thru 277V) 20V 2 277V 3 347V Voltage pg. 3 Mounting pg. 3 DRIVER CIRCUITING BATTERY & EMERGENCY4 FINISH OL Osram (0%, 00v, standard) OL2 Osram (%, 00v) OL3 Osram 347v (0%, 00v) EE eldoled ECOdrive (%, 00v) EE3 eldoled ECOdrive (%, DALI) PL2 Philips Xitanium (%, 00v) PS Philips Xitanium (50%/00%) LH Lutron Hilume (%, EcoSystem) LH3 Lutron Hilume (%, 3wire) L5 Lutron 5Series (5%, EcoSystem) ND NonDimming Single Circuit M Multi Circuit EE mergency 0 None _P Philips Bodine 0W _I Iota 0W _IC Iota 0W (CEC Listed) _E Emergency Circuit Section _N Night Light Circuit Section _L Life Safety Circuit Section _G Philips Bodine GTD W White S Metallic Silver BL Textured Black BR Bronze GR Graphite CC Custom Color (entire fixture) NN ight Light (entire fixture) Circuiting pg. 4 Finish pg. 4 Battery and Emergency pg. 4 Driver pg. 4 FIXTURE OPTIONS QS QuickShip CP Chicago Plenum MRF Fixed MR6 Halogen LMRF Fixed MR6 LED RC Rotating Crossbar LC Clear Lens B Baffle GLR Internal Fast Blow Fuse CONTROLS Pinnacle is able to accommodate different control solutions from different manufacturers. Consult Factory for more information. Fixture Options pg. 5 For Quickship CRI, CCT & Output see chart on page 5 2 Individual fixtures come in 2, 3, 4, 5, 6, 8 lengths.continuous row come in increments. 3Specify mounting for continuous length: G, G9, GS, FL, NF & SF for continuous rows, GG, G9G, GSG, FLF, NFN & SFS for individual lengths. 4 Enter quantity for Battery and Emergency, Example 2P. Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacleltg.com are the most recent version and supersede all other previously printed or electronic versions. Designed and Fabricated in Denver, CO USA pinnacleltg.com O: 3033225570

CRI, CCT & Output Specify either 80 or 90 CRI Longer leadtime may apply for 90 CRI. Consult factory Custom Output Lumens OR Wattage 80 CRI = R9 9 and 90 CRI = R9 6 CL _ Specify CRI, CCT and desired lumens (i.e. CL835700) Specify lumens between standard offering listed below. Lumens are specified per color temp CW _ Specify CRI, CCT and desired wattage (i.e. CW9407) Specify watts between standard offering listed below 80 CRI Color Output Watts Shielding per foot WW Wall Wash Lumens/ft LPW 830 3000K Standard 6.0 329 54.6 830HO 3000K High 0.3 5 49.7 835 3500K Standard 6.0 343 56.9 835HO 3500K High 0.3 534 52.0 840 4000K Standard 6.0 352 58.4 840HO 4000K High 0.3 548 53.3 90 CRI 927 2700K Standard 6.0 270 44.8 927HO 2700K High 0.3 420 40.9 930 3000K Standard 6.0 304 50.5 930HO 3000K High 0.3 47 45.8 935 3500K Standard 6.0 309 5.3 935HO 3500K High 0.3 48 46.8 940 4000K Standard 6.0 34 52. 940HO 4000K High 0.3 489 47.6 Length Individual units cannot be joined, end trims are factory installed and cannot be removed Continuous Rows are made up of even and odd length fixtures; designed to fall ongrid 2 3 4 5 6 8 _ Indiv. Fixture Indiv. Fixture Indiv. Fixture Indiv. Fixture Indiv. Fixture Indiv. Fixture Cont. Run 23 (584.2mm) Specify nominal overall row length 35 (889mm) to the 47 (93.8mm) 59 (498.6mm) 7 (803.4mm) 95 (243mm) Specify to the Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacleltg.com are the most recent version and supersede all other previously printed or electronic versions. Designed and Fabricated in Denver, CO USA pinnacleltg.com O: 3033225570 F: 3033225568 pg. 2

Mounting Individual Units: specify G_G, FLF, SFS, NFN Continuous Runs: specify G_, FL, SF, NF All individual units cannot be joined, end trims are factory installed and cannot be removed Designed to install into acoustical grid and inaccessible ceilings Grid retention brackets integral to housing and require mechanical attachment Each housing contains 4 grid retention brackets Tie off fixture to structure with retention wires Approved for dry/damp location unless otherwise noted GG Individual Unit G9G GBG GSG FLF NFN SFS G Continuous Run or Pattern G9 GB GS FL NF SF " (5/6 ) TBar 9/6 TBar For tegular tile installations, fixture position will not be flush to the bottom of the tile 9/6 TBar Rail has bevel edge details. For tegular tile installations, fixture position will be flush to the bottom of the tile Screw Slot & 9/6 TBar For 9/6 installations with tegular tile, fixture position will be flush to the bottom of the tile Exposed Standard /2 Flange Detail Metal Pan or Millwork Drywall, Flangeless Detail Standard Tile Standard Tile Tegular Tile Tegular Tile Tegular Tile Tegular Tile Tegular Tile Voltage Some EV3WW configurations will not accommodate all voltage options; consult with factory U Universal 20 volt 2 277 volt 3 347 volt Driver Standard Driver Option = OL Driver Lifetime: 50,000 hours at 25 C ambient operating conditions For more driver options see Pinnacle Resource Guide Some EV3WW configurations will not accommodate all driver options; consult with factory OL Osram Optronic 0%, 00v OL2 Osram Optronic %, 00v, nominal % dimming range OL3 Osram Optronic 347v 0%, 00v, requires 347v option EE eldoled ECOdrive %, 00v Logarithmic EE3 eldoled ECOdrive %, DALI Logarithmic PL2 Philips Advance Xitanium %, 00v PS Philips Advance Xitanium Step Dimming 50%/00% LH Lutron Hilume Softon, Fadetoblack %, EcoSystem, LDE LH3 Lutron Hilume %, 3wire, LutronL3DA3W L5 Lutron 5Series 5%, EcoSystem, LDE5 ND NonDimming Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacleltg.com are the most recent version and supersede all other previously printed or electronic versions. Designed and Fabricated in Denver, CO USA pinnacleltg.com O: 3033225570 F: 3033225568 pg. 3

How to specify Circuiting, Battery and Emergency Select fixture circuiting from options below Some EV3WW configurations will not accommodate all circuiting options, consult with factory Circuiting Single Circuit M Multi Circuit E Emergency Circuit only N Night Light Circuit only 2 + 3 Battery and emergency section options are available in addition to fixture circuit Select battery and emergency section options below; factory shop drawing required Some EV3WW configurations will not accommodate all circuiting options, consult with factory Battery and/or Emergency If Required 0 No battery or specific emergency section required Battery Select battery section type if required, indicate total QTY. Example 2P 90 minute battery runtime; test button is remote No battery option available for 2 lengths Entire fixture is on battery for lengths up to 5 Half of fixture is on battery for 6, 8 housing lengths For more battery options available, see Pinnacle Resource Guide For Approximate Battery Lumen Output Multiply battery wattage X fixture LPW shown on Lumen Table 92.3 (LPW) x 0 (watts) = 923 battery lumen output 0 No battery _P Philips Bodine 0w Integral _I Iota 0w Integral _IC Iota 0w Integral CEC Listed Emergency Select emergency section type if required, indicate total QTY. Example E Combine battery and emergency section ordering codes if both options are selected _E _N _L _G Emergency circuit section Night Light circuit section Life Safety circuit section NO THROUGH WIRE Philips Bodine GTD, Generator Transfer Device section Battery OR Emergency Ordering Examples Single circuit, 0w Integral Battery Ordering Code: P Emergency only, 0w Integral Battery Ordering Code: EP Single circuit, GTD required Ordering Code: G Combination Section Ordering Examples Single circuit, () 0w battery, () emergency section Ordering Code: PE Multi circuit, (2) 0w battery, (2) emergency sections Ordering Code: M2P2E Single circuit, () night light section Ordering Code: N Finish Standard powdercoat textured white, metallic silver, textured black, graphite or bronze painted finish; consult factory for chip of standard paint finishes Selecting a fixture finish other than white may impact lumen output; consult factory for more information W S BL GR BR CC White Metallic Silver Textured Black Graphite Bronze Custom Color Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacleltg.com are the most recent version and supersede all other previously printed or electronic versions. Designed and Fabricated in Denver, CO USA pinnacleltg.com O: 3033225570 F: 3033225568 pg. 4

Fixture Options Additional options to enhance the fixture and finish of the product Consult factory for MR6 configurations QS CP MRF LMRF RC LC B GLR Quick Ship Chicago Plenum Fixed MR6 Halogen Fixed MR6 LED Rotating Crossbar Clear Lens Baffle Internal Fast Blow Fuse Quick Ship Shielding CRI, CCT & Output Mounting Voltage Driver Circuiting Battery Finish Options 0Day EV3WW 80 CRI, all color temperatures, all lumen packages See pg 4 G(G) G9(G) GS(G) FL(F) NF(N) TBar 9/6 TBar Screw Slot /2 Flange Flangeless U 2 Universal OL (20277) 20V 277V LH Osram 00v, 0% Lutron LDE E N Single Circuit Emergency Night Light P I Philips Bodine 0w Integral Iota 0w Integral W White CP GLR Chicago Plenum Internal Fast Blow Fuse All lengths and continuous rows up to,000 ft OR 50 individual fixtures. Consult factory for larger projects. Controls Pinnacle is able to accommodate different control solutions from different manufacturers. Consult Factory for more information Photometrics Wall Wash Test # ITL82933 Catalog # EV3WW8404 Lumens 406 lm Watts 24. W Efficacy 58 LPW 042 782 52 26 Candela Distribution Luminance Data (cd/sq.m) Vert Angle Horizontal Angle Angle In Degrees Average 0Deg Average 45Deg Average 90Deg 0 22.5 45 67.5 90 45 9888 24775 3832 0 566 566 566 566 566 55 7529 2063 380 5 793 73 567 434 37 65 5088 7640 38063 0 996 89 563 30 230 75 620 492 388 5 038 999 554 20 40 85 9643 0232 28436 20 903 06 54 44 88 25 709 926 523 96 69 30 58 765 503 73 57 35 470 6 476 6 48 40 4 509 446 50 39 45 373 408 42 4 29 50 342 35 376 33 55 36 30 336 24 4 60 287 275 292 7 3 65 252 243 248 3 70 24 208 204 2 75 73 67 57 0 80 46 24 06 0 85 22 96 4 0 0 90 95 70 0 0 0 Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacleltg.com are the most recent version and supersede all other previously printed or electronic versions. Designed and Fabricated in Denver, CO USA pinnacleltg.com O: 3033225570 F: 3033225568 pg. 5

Applications & Certificates Construction: Formed coldrolled 20 gauge steel housing. Highly reflective dieformed white painted aluminum reflector. Shielding: Diffuse snapin acrylic lens, removable for maintenance. Mounting: EDGE is designed to install into acoustical grid and inaccessible ceilings. Specify GXG, FLF, SFS, NFN for individual, unjoinable units (individual units will fall ongrid). Specify GX, FL, SF, NF for continuous runs (runs designed to fall ongrid). Consult factory for detailed installation instructions. Maximum fixture weight is 5lbs per 4 fixture. LED: 25 C test environment. Lumen output/wattage has a margin of +/ 5%. All luminaire configurations tested in accordance with IES LM79. Diodes tested in accordance with IES LM80. Minimum lifetime greater than 60,000 hours. Lifetime Projection L70 = 22,900 hours and L90 = 36,600 hours. MacAdam 3Step Ellipses. Not all products are Lighting Facts listed. For all available IES files, please visit our website at pinnacleltg. com. CRI, CCT & Lumen Output: Two lumen packages available. Standard and High (HO). Custom outputs are available. Specify custom lumens or watts between standard offering listed on CRI, CCT & Output page. 80 CRI is available for 3000K, 3500K, and 4000K. 90 CRI is available for 2700K, 3000K, 3500K, and 4000K. 80 CRI = R9 9 and 90 CRI = R9 6. Voltage: Universal (U), 20 volt (), 277 volt (2) and 347 volt (3) options available. Must specify OL3 in Driver section when 347 volt (3) is selected. Some EDGE configurations will not accommodate all voltage options; consult with factory. Driver: Standard Driver Option is Osram 00V, 0% = OL. Electronic driver, Power factor is >0.9 with a THD <20%. Driver Lifetime: 50,000 hours at 25 C ambient operating conditions. Ambient operating range: 20 F/30 C to 96 F/35 C. For more driver options, see Pinnacle Resource Guide. Some EDGE configurations will not accommodate all driver options. Circuiting: Select from single circuit (), Multi circuit For multiple circuiting and zone control, requires factory shop drawing (M), Emergency circuit (E), Life Safety (L) or Night Light circuit (N). For emergency circuiting situations that require no through wire or circuit separation, Life Safety Circuit should be selected. This will provide a separate power feed and only the Life Safety Circuit in that section. Some EDGE configurations will not accommodate all circuiting options; consult with factory. Battery & Emergency: Select battery or emergency options if required. If battery or emergency option is not required, enter 0. Battery duration is 90 minutes as standard. Test button is remote to fixture. For more Battery options, see Pinnacle Resource Guide. Finish: Standard powdercoat textured white, metallic silver, textured black, graphite or bronze painted finish; consult factory for chip of standard paint finishes or for additional custom color and finish options. MR6: Ideal for conference rooms, corridors, wall washing, retail spaces and training facilities where accent lighting is required. Fully enclosed compartment eliminates light from entering into our fixture areas. For LED and Halogen lamps (lamps are not included). Consult factory for other lamp types. Standard 60 watt max LED electronic transformer (20v or 277v), 50 watt max halogen lamp transformer (20v or 277v), MR6 installed as an independent circuit. MR6 to match fixture voltage. 277v dimmer must be sourced. Consult factory for MR6 configurations. Controls: Specify PD for daylight sensor, requires 00v driver. Some EDGE configurations will not accommodate all control options; consult with factory. Labels: UL and cul Listed. Standard and HO lumen packages are IC Rated, approved for dry/damp location unless otherwise noted. Fixture Weight: Maximum fixture weight is 5lbs per 4 fixture. Buy American Act Compliant Warranty: EDGE LED offered with a 5year limited warranty. Covers LED, driver and fixture. Specifications and dimensions subject to change without notice. Specification sheets that appear on pinnacleltg.com are the most recent version and supersede all other previously printed or electronic versions. Designed and Fabricated in Denver, CO USA pinnacleltg.com O: 3033225570 F: 3033225568 pg. 6