EasyStart. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

Similar documents
Easy Start. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

Micro-Air Corporation Route 526 Allentown, NJ 08501

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

EasyStart Installation Instructions for Dometic Family RV A/Cs

Advanced EasyStart Troubleshooting

UNISTEER Performance Products UNIVERSAL HOT ROD ELECTRA-STEER KIT

INSTALLATION/OPERATING INSTRUCTIONS MCP

HP21 SERVICE SUPPLEMENT UNIT INFORMATION. TSC6 Two-Speed Control

Mechanical Spiral Sensor

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION

INSTALLATION/OPERATING INSTRUCTIONS TSC

POWERLINE 2000 Energy Management System TM

USER MANUAL AND INSTALLATION GUIDE ENGINE RPM AND NOS SHIFT COUNTER NOS DELAY TIME IN SECONDS NOS START PERCENT NOS FINAL PERCENT


MODEL MCL /8 SPEEDOMETER/TACHOMETER for 2004 up

MODEL MCL-3212 SPEEDOMETER/TACHOMETER for 2012 up Dyna and Softail with 4 gauge

Gas Spreader PLUS Remote Kit With Built in Clutch Relay and On/Off Switch

ION-01-6 PERFORMANCE SPEEDOMETER/TACHOMETER COMBO

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

SCHNITZ MOTORSPORTS PNC-202, 2-STAGE PROGRESSIVE NITROUS CONTROLLER USER MANUAL AND INSTALLATION GUIDE NOS PULSE FREQUENCY

XPS-ProFeed Shuttle SERVICE MANUAL. Revised:

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

Installation Instructions Electric Heaters 5 20 kw

GLM SERIES CONTROL Users Manual Rev:

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

BLHV, BLHV-1. High Voltage Step Motor Driver. User s Guide. (714) fax: (714) website:

TROUBLESHOOTING GUIDE FOR HEAT PUMP BOOSTERS MODELS: HPB11, HPB15, & HPB22

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

Control Panel Interface Upgrade Installation Guide For Model 200i and 250i Motorcycle Dynamometers Serial Number 202xxxx.

ODYR-19-5 & SLX-19-5 DUAL, TRIPLE, or QUAD AIR PRESSURE GAUGE

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

50 AMP Smart Energy Management System Model 800 SERVICE MANUAL 50 AMP SMART EMS. 50 Amp EMS Display Panel P/N A I N A I N

MCS-EXV DRIVER. Operation Manual Control of Bipolar Expansion Valves Rev 1.8. MCS Total Solution for all your Control Needs

DESCRIPTION & OPERATION

REMOVAL OF FACTORY GAUGE ULTRA FLHT & FLHX (STREET GLIDE

TB-690 Conveyor/Stacker

Model LA 4400 Time Delay OFF Controller

MKV Jetta OEM Fog Installation Instructions

1999 Mercury Cougar ACCESSORIES & EQUIPMENT' 'Passive Anti-Theft Systems - Cougar 1999 ACCESSORIES & EQUIPMENT

ACCESSORY KIT INSTALLATION INSTRUCTIONS

Generator Start Control Module

STANDARD AND GROUND SWITCHED APPLICATIONS

Model LA 4300 Time Delay OFF Controller

MODEL 422 Submersible Pump Controller

POWER PINNER RAPID FIRE 7005 RF OPERATOR S MANUAL

HLY-1111 HEAD TEMPERATURE GAUGE

SELECT -24 INSTALLATION GUIDE. INST036 Doc 2.02

Owner s Guide PR1BZ PR1BZLR

Owner s Guide CARS & CA4B5

STL Dart TIR Exterior LED Traffic Advisor Arrow Stick

Model LA 4100 Time Delay OFF Controller

CMD-4000 SERIES REV. A 4+ FUNCTION REMOTE CONTROL DOOR LATCH OPENER SYSTEM INTRODUCTION

MCL-30K-TCH. Remove nuts/screws and clamp to remove factory gauges 1 MAN#650336

HWP Protection Board

Model C230 Pump Controller

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

B1C29 LEFT SIDE SEAT THORAX S... B1C29 LEFT SIDE SEAT THORAX SQUIB 1 OPEN. 6/14/2016 Direct Hit Search

Patient Care Facility

Generator Start Control Module

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

MBD Enhanced Step Motor Driver. User s Guide #L East Orangefair Lane, Anaheim, CA

KEYLESS ENTRY SYSTEM & TIRE PRESSURE MONITOR ACCESSORIES & EQUIPMENT General Motors Corp. - Remote Keyless Entry System

ODY-19-6 DUAL, TRIPLE, or QUAD AIR PRESSURE GAUGE

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS


Charging Hub for Inspire 1 Intelligent Flight Batteries

MCL-5100, 5200, & 5400 Bar mount digital speedometer with indicators.

STL Striker /Virtue Interior LED Traffic Series

DPS32001 and DPS32PS1

Installation Manual for VMAC Throttle Commander

STL Rear Raptor Linear Interior LED Visor Light Bar

SBC V In-Car Charger Dual Input (Solar MPPT & DC)

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Owner s Guide APS596Z

G203V / G213V MANUAL STEP MOTOR DRIVE

ODY-19-1 AIR PRESSURE GAUGE

ODYR-25-1 & SLX-25-1 rev. A VACUUM/BOOST PRESSURE, TEMP, and EGT GAUGE

SCHNITZ MOTORSPORTS USER MANUAL AND INSTALLATION GUIDE PRO-MOD BATTERY VOLTS DIAGNOSTICS NOS PULSE FREQUENCY NOS DELAY TIME IN SECONDS

FOR AUTOMATIC TRANSMISSION AND DIESEL ENGINE VEHICLES

PAC-3100 LINEAR MOTOR CONTROLLER W/ CURRENT SENSING AUTO REVERSE

EMIU 720W Mini Inverter

L I M I T E D L I F E T I M E W A R R A N T Y

USER MANUAL AND INSTALLATION GUIDE TIMER DELAY IN SECONDS SHIFT STYLE & SHIFT COUNTER TIMER DURATION NOS DELAY TIME IN SECONDS NOS START PERCENT

INSTALLATION GUIDE. FCC ID NOTICE

UNIVERSAL ELECTRA-STEER FOR 2 COLUMN 220w Plain w Polished w Plain w Polished

Holden VZ 3.6L ECU & Powertrain Interface Module Linking Instructions

30A SMART ENERGY MANAGEMENT SYSTEM TM

Application Engineering Europe

Auto-Trol Limited 1660 SW 196th Avenue * Aloha, OR 97003

INSTALLATION INSTRUCTIONS 5.7L HEMI TRUCK HOT-ROD STYLE. Also covers LX 5.7L/6.1L Hemi with Truck or Manual Transmission **

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

ICM325HN. Head Pressure Control with Optional Heat Pump Override. Installation, Operation & Application Guide

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

Patient Care Facility

DUAL LINEAR MOTOR / ACTUATOR CONTROLLER W/ CURRENT SENSING AUTO REVERSE

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

Idle Free Systems, Inc. Reference Guide System Component Information

Owner s Guide CA 4555

STL K-Force 18 and Micro 14 LED Mini Light Bar

Transcription:

EasyStart 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter Installation Manual Micro-Air Corporation www.microair.net 124 Route 526 Phone (609) 259-2636 Allentown NJ 08501 Fax (609) 259-6601

Retrofit Instructions: 1. Read and understand these instructions completely before proceeding. Improper wiring can result in damage to EasyStart or connected components including but not limited to wiring, compressors, and capacitors. Micro-Air Corp is not responsible for damages to any of the aforementioned equipment caused by improper wiring. 2. Turn off the breaker for the compressor s electrical system. 3. Identify an appropriate location for EasyStart that allows mounting with the EasyStart wire exit pointing up. Securely mount the EasyStart box and route the wiring into the existing run capacitor location. Be sure to secure the harness to prevent vibration or movement damage. 4. Consult the manufacturers installation manual and wiring diagram for the identification of the following: a. Compressor R, C, and S terminals and associated wire color for each connection. Compressors have a plastic cap with a single hex nut covering the connections. Wires can usually be identified without removing this cover however the cover or markings near the terminals can also be used to identify the wires. b. Run capacitor (typically in a metal can). This capacitor will have 2 or 3, multi-point terminal group connections. c. Control board switched-l1 output or main contactor compressor L1 output connecting to the compressor common C terminal wire. Note some systems utilize a contactor to switch power to the compressor, other use a power relay integrated into the main control board. 5. Identify the wire color connected to the compressor S terminal and follow the wire to the run capacitor. Disconnect any other wire connected to the same terminal group. Follow the disconnected wire and remove it from the connector on other end. If the wire goes into a PTC device simply follow the second wire coming from the device, disconnect it and remove the PTC. Not all systems will have a second wire on this terminal group. 6. Connect the orange wire from EasyStart to the same terminal group identified in step 5. 7. Locate the wire connected from the compressor run winding R terminal to the run capacitor C terminal, and disconnect it from the run capacitor. Connect (splice) the brown wire from EasyStart to the disconnected wire. 8. For compressors under 3 tons (36 KBTU), connect the white wire from EasyStart to the same terminal of the run capacitor from which you disconnected the (white) run winding R wire in step 7 above. For all other compressors, splice the white wire to the L2 wire that feeds the run capacitor or connect it to the L2 connection at the contactor. 9. Connect the black wire from EasyStart to the switched-l1 connection coming from the main control board or main contactor that typically has a black or purple wire that connects to the compressor common terminal wire. 10. Wiring is now complete. Close all open electrical boxes and panels. 11. Turn on the system circuit breaker using shore power. Start a heating or cooling cycle with the thermostat. 12. EasyStart will now learn the characteristics of the compressor for the next five starts. This operation can be done during normal operation and does not require any intervention or special actions. Once the learning process is completed, the EasyStart can be operated on either shore or generator power. You must wait five minutes after the compressor stops for the compressor to restart. See Anti-Short Cycle Timer for details. IMPORTANT INSTALLATION NOTE FOR CRUISAIR MARINE CUSTOMERS ONLY: When installing EasyStart into 230V SMX control applications that use the triac to switch power to the compressor, it is necessary to replace the triac with a relay. If the triac is not replaced, the pump relay triggers may suffer damage and ultimately fail. Please note that this is not required for 115V SMX applications and the triac is still safe to use. Visit the Micro-Air website or contact Micro-Air for details on the appropriate relay.

Example EasyStart Installation Wiring Diagram:

Jumper Usage: A six pin diagnostic header is located inside the EasyStart box. Most installations will not need to access this header. Jumpers may be placed on JP1 for certain special functions. Place jumpers only as shown below. Normal: Most operation should be done without a jumper installed on JP1 or with the jumper installed across pins 3 and 4 as shown. Default: A compressor may be operated with a factory defined start characteristic. This may not be the optimal start for the connected compressor and is generally used for factory diagnostics. No optimization is done with this setting. Relearn: If a compressor, start capacitor, or run capacitor is replaced, place a jumper on pins 4 and 6 as shown. Cycle power on then off again and replace the jumper in the Normal position. Follow step 13 of the retrofit instructions to complete the relearn process. Disable: This setting disables the microprocessor on the board so no operation can occur. Short-Cycle Prevention Timer: EasyStart models incorporate a timer that prevents immediate restarts. This feature was added to prevent overheating of the start capacitor and reduce faults due to un-equalized pressures in the system. Restart will take up to 5 minutes if power is removed then reapplied. Later models include a wire jumper JP2 (see picture on right) that can be cut to eliminate this feature. System controls must be sufficient to prevent short cycling if this jumper is cut. Warning: Starts must be limited to 1 start every 5 minutes with pressures equalized if JP2 is cut.

EasyStart Troubleshooting: See the Micro-Air guide EasyStart Advanced Troubleshooting Guide available on our website for assistance in troubleshooting EasyStart installations. Fuses: Protection fuses are installed in the start circuit to prevent damage due to miswiring or start capacitor failure. If this fuse fails in normal operation, there is most likely a problem with the start capacitor which should be replaced along with the fuse. 364 (3 ton) 1. Revision H and earlier boards: These boards incorporate a non-replaceable fuse in the start circuit. These units must be returned to Micro-Air for repair. 2. Revision I and above boards: These boards incorporate a replaceable 15A 250V rated, slow blow, 5mm x 20mm glass fuse. 368 (6 ton) 1. Revision E and earlier boards: These boards incorporate a non-replaceable fuse in the start circuit. These units must be returned to Micro-Air for repair. 2. Revision F and above boards: These boards incorporate a replaceable 30A 250VAC rated 3AB, 3AG, ¼ x 1 ¼ (6.35mm x 31.75mm) slow blow ceramic fuse. FAQs: What is re-learning? The re-learning process simply clears the EasyStart memory and returns it to as shipped condition. EasyStart should be re-learned whenever a compressor is changed or if pressures were not allowed to equalize during the learning process. To re-learn EasyStart, remove power and open the EasyStart box. Locate the 6 pin header shown in the jumper usage section of this manual and place the shorting jumper over pins 4 and 6 as shown. Start a cycle with your thermostat with the compressor powered from AC mains and allow EasyStart to start the compressor. Remove power once the compressor starts and replace the jumper to the stored position over pins 3 and 4. Replace the cover on EasyStart and complete at least 4 additional starts. Be sure to allow time for pressures to equalize between starts, usually 3 to 5 minutes. Be sure to remove the jumper from pins 4 and 6 and replace it to pins 3 and 4 immediately after the FIRST start and after power is removed. I connected everything and it just won t start. What do I do now? Micro-Air has an entire guide to help troubleshoot problems from new installations to systems that were working and develop a problem at www.microair.net. If there are any questions about wiring your unit, you can send a wiring diagram for your compressor to help@microair.net along with your question.

COPYRIGHT 2017 Micro-Air Corporation, All Rights Reserved No part of this publication may be reproduced, translated, stored in a retrieval system, or transmitted in any form or by any means electronic, mechanical, photocopying, recording or otherwise without prior written consent by Micro-Air Corporation. Every precaution has been taken in the preparation of this manual to insure its accuracy. However, Micro-Air Corporation assumes no responsibility for errors and omissions. Neither is any liability assumed nor implied for damages resulting from the use or misuse of this product and information contained herein.