Innovative Controls Inc. SL Series Tank Level Monitor

Similar documents
TANK INDICATOR. PRIMARY and REMOTE DISPLAYS

TANK INDICATOR WLA200 WATER TANKS WLA260 CLASS A FOAM CONCENTRATE TANKS WLA270 CLASS B FOAM CONCENTRATE TANKS

Engineering Standards. Engineering Standard Number C A. Name. Digital Breathing Air Remaining System BREATHING AIR

RP100 Series. 2.4GHZ Extended Range. 32-bit Microprocessor. Radio Receiver Model: RP100 / RP / 10 Digital Output

8000 Series Liquid Flow Meters

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

8000 Series Liquid Flow Meter

MT-1 Tracer Meter. RENOGY MT-1 Tracer Meter for Duo Battery Charge Controller E. Philadelphia St., Ontario CA

SSI Technologies Application Note PS-AN2 MediaSensor Absolute & Gage Pressure Transducers & Transmitters Product Overview

2-Color Display High-Precision Digital Pressure Switch Series ZSE40A(F)/ISE40A

SIGNETMARINE. Livewell Bait Pump Alarm. No Dead Bait.

744A SprAyer Control U S e r M A n U A l

NTC Thermistor Assemblies

High Intensity Colored LED Light - 90 Watts - 30 LEDs - Red, Amber, Green, Blue

Application Engineering

Instruction Manual. Duo-battery Solar Panel Controller EPIP20-DB series For Both 10 and 20 amp. Controllers (for use with solar panels only) + -

10 switches simultaneously. The settings of the master sensor (source of copy) can be copied to the slave sensors. Reducing setting labor

Engineering Standards

AutoFarm GPS AutoSteer Hardware Installation Guide

160 Watt High Intensity LED Flood Light - 24 LEDs - 20,500 Lumens W Halogen Equivalent

2015 June NEW PRODUCTS / MAXXIMA. Hybrid LightningS PAGE 5 Low Profile 4 PAGE 2 MWL-31SP PAGE 3 M20344 PAGES 6

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Application Engineering

Low Profile, High Intensity LED Light Bars - 27, 3-Watt LEDs VDC Lumen

install guide OEM-IDS(RS)-BM1-[ADS-BM1]-EN

SSI Technologies Application Note PS-AN7 MediaGauge (Model MG-MD) Digital Pressure Gauge Product Overview

System III Wiring Information 54-12

BITZER Capacity Controller for CSH Compressors Temperature Sensor

Alarms & Remote Start

Engineering Standards. Engineering Standard Number C A. Name. Digital Oxygen Remaining System O2 REMAINING

3 Phase Smart Controller

CP 634 DELUXE 4-CHANNEL KEYLESS ENTRY SYSTEM

Installation and Operating Manual

Series 10-ZSE40A(F)/10-ISE40A

Sentry Governors. Class 1. Advanced Diagnostics. Sentry Governor Kits

install guide COM-IDS(RS)-BM1-[ADS-BM1]-EN

Tips for Installation, Calibration and Operation of SmartSwitch Tank Management Systems. Contents: Page

INSTALL GUIDE AKX-IDS(RS)-BM1-[ADS-BM1]-EN

ECO3-601/602 EcoStar III * Chevy Express/GMC Savana Contact Intermotive for additional vehicle applications

REVISION HISTORY REVISION HISTORY

MEGA 462 REMOTE CONTROL AUTO ALARM SYSTEM INSTALLATION & OPERATION INSTRUCTIONS WIRING DIAGRAM. White. H1 5 Pin White. H6 2 Pin White.

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

Work Lighting Lampe de Travail Iluminación de Trabajo

Industrial Pressure Transmitters

Tank Filling Systems for Petroleum Products

CANADA SENSORS TECHNOLOGY INC.

INSTALLATION MANUAL & OPERATING INSTRUCTIONS

The Original fire truck liquid filled gauge - more refined and rugged than ever with these special features:

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

ILLUMINATED WINDPRO WITH LED. User Manual. STREET-MASTER Illuminated LED. Rolling Base Pavement Sign

Programming Instructions for : Pressure 2 1/16 + DOWN MODE UP. Spek Pro Fuel Rail Pressure Gauge

SPECIFICATIONS OXYMAX SUB-SURFACE AERATION SYSTEM

Display Installation. page 1 of 9 pages. Engineering Standards. Engineering Standard Number C A. Name Identifier

LTX RF LEVEL SENSOR. Instruction Manual

Cleaning Systems Inc. 2 P Rev:03

GENSET CONTROL MODULE A121A / A241A

Altec LMAP. (Load Moment and Area Protection) Telescopic Boom Cranes. Calibration

Switch select of sender types:

18 Watt LED Flood Light Lumens - Six 3-Watt LEDs Volt DC - IP67 Waterproof

QUANTUM LX CONTROL PANEL

DIAPHRAGM SEALS. MHP SERIES MINI HIGH PRESSURE Mini diaphragm seal for pressures up to 6000 psi

Gem 2000 Electronic Guardian

SPEK PRO MONITOR AND CONTROL

Installation and Operations Manual

ISO 9001, ISO1400, ISO13485, CE and WHO-GMP certified.

ODY-05-2 VOLTMETER FOR REMOTE MONITORING

30A SMART ENERGY MANAGEMENT SYSTEM TM

FROG-D 3P. FREQUENCY READOUT OF GENERATOR THREE PHASE GENERATOR DISPLAY MODELS: FDA700 for Delta Winding FDA710 for Star Winding

CONTROL BOX. Wiring the control box into the vehicle. +12V

STYLE 3491 Severe Duty Electric Mining Water Cannon INSTALLATION, AND OPERATING INSTRUCTIONS

MONSTER INDUSTRIAL LIGHTING

To ensure proper installation, digital pictures with contact information to before startup.

License and Backup Feux de Plaque d Immatriculation et de Recul Lámparas de Placa / Reversa

MULTIRACK GARNET. Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL. 688 Manual. Page 1. Printed in Canada

Covers All 430, 440, 441 and CJ Series Advanced Security Systems.

ID BAR INCANDESCENT IDENTIFICATION LAMP INCANDESCENT IDENTIFICATION LAMP INCANDESCENT IDENTIFICATION LAMP DRAGON'S EYE ID BAR

Low brightness and uplighting combine to create a pleasing visual environment. Softbay Series

CAPSU-PHOTOHELIC PRESSURE SWITCH/GAGE*

MCL-3014 gauge kit. Optional Readings: Boost Pressure with MBM-09, Front or Rear Air Suspension Pressure with MBM-19

ANALOG CONTROL PANEL

install guide OEM-IDS(RS)-BM1-[ADS-BM1]-EN

Commander IS0128 ISO128E ECR# /04. Tachometer/ Engine Hourmeter

TROUBLE SHOOTING FOR NEGATIVE GROUND TRUCKS

INSTALL GUIDE IDL-IDS(RS)-BM1-[ADS-BM1]-EN

The company 4. CM Series Engine Control Panel 6 CM 40 Series CM 20/30 Series CM 2A/3A Series CM 02 Series CM 60 Series

Interior Lighting Lumières d Intérieur Lámparas para Interior

INSTALL GUIDE DIR-IDS(RS)-BM1-[FLRSBM1]-EN

Therm-L-Tec Building Systems LLC. Therm-L-Tech. Power Operated Retrofit Kit 230 VAC or 440/480 VAC 50/60 Hz Installation and Setup Manual

DP10001 UNIVERSAL 5 GAUGE DIGITAL PANEL

Paddle Wheel Turbine Flow Meters Installation, Operating & Maintenance Manual

10 lighting. 2 Work Lights 5 Lamps & Mounting Accessories 5 LED Lamps & Mounting Accessories 9 Work Lamps 10 Incandescent Lamps 12 Bulbs

SECOND GENERATION Use this guide with unit serial number prefix beginning with BWF using Terra Power separator.

LPP-M PUMP THE SOLUTION YOU VE BEEN LOOKING FOR

Senior Swing Control Box. Table of Contents

for ethanol applications

Model 277EC ENGINE IDLE LIMITER

INSTRUMENTATION & CONTROL

NOTICE FOR ALL EG21 ELECTRIC GAGES AND EGS21

Crane Systems GREER COMPANY. LALT 1151L System for Lattice Cranes. Installation and Calibration Manual. 1 of 39

182 Pigtails, Brackets and Grommets

Transcription:

WATR OAM Innovative Controls Inc. SL Series Tank Level Monitor

The decorative mounting bezel is chrome plated to the most stringent SA standards. Both 14 LD and 10 LD master and slave display modules feature 3 dimensional lenses for 180 degree visibility. All SL display modules are easy to install requiring a simple rectangular hole and 4 screw holes. Photo-eye automatically dims or brightens LDs as ambient light conditions change. WATR OAM WATR OAM WATR Both 10 LD and 14 LD dual displays are available as a more compact, economical, and easier-to-install alternative to individual tank level displays. 5 LD mini slave displays feature the same rugged construction and related benefits as the larger display modules. All display modules are self-calibrating for three common tank styles (rectangular, elliptical, and T-shaped). A user-friendly manual calibration mode is accessible, if desired, and can be done without any truck or system disassembly. An external magnet is held in front of the display to calibrate the system. The calibration information is stored in the display unit. All SL display module electronics are encapsulated in potting compound to protect the unit from shock, vibration, water and dust. All connectors are water and dust resistant and feature gold plated contacts for superior reliability. Bright, bold, easy-to-read graphics are sub-surface screened on a polycarbonate overlay, which protects the graphics from wear and UV degradation. unctional Specifications: Level Sensing Range: our discrete factory and user adjustable sensing levels. Accuracy: 2.0% of set level Supply Voltage Range: +10VDC to +26VDC supply voltage range with protective shutdown above 30VDC Operating Temperature Range: -40 o to +150 o Maximum Supply Current: 350mA @ 12VDC Bid specifications available: Bid Specifications Date Originated: 02/28/05 Revision: A Revision Date: 02/28/05 Standards No. 5000047 Subject: SL Series Tank Level Monitor Bid Specifications - 10-LD Master oam A Unit 10-LD Master Class A oam Tank Level Monitor An shall be installed. The system shall include an electronic display module, a pressure transducer-based sender unit, and a 10' connection cable. The display module shall show the volume of Class A foam in the tank using 10 superbright easy-to-see LDs. Tank level indication is enhanced by the use of green LDs at the full and near-full levels, amber LDs between ¾ and ¼ tank levels, and red LDs at the near-empty and empty levels. A wide-angle diffusion lens in front of the LDs creates a 180 viewing angle. The electronic display module shall be waterproof and shock resistant being encapsulated in a urethane-based potting compound. The potted display module shall be mounted to a chrome plated panel-mount bezel with a durable easy-to-read polycarbonate insert featuring red graphics and a foam icon. All programming functions shall be accessed and performed from the front of the display module. The programming includes self-diagnostics, manual or self-calibration, and networking capabilities to connect remote slave displays. Low tank level warnings shall include flashing red LDs starting below the ¼ level, down-chasing LDs when the tank is almost empty, and an output for an audible alarm. The display module shall receive an input signal from a pressure transducer. This stainless steel sender unit shall be installed on the outside of the foam tank near the bottom. All wiring, cables and connectors shall be waterproof without the need for sealing grease. Location of Class A foam tank level monitor shall be: The easy-to-install sender unit is constructed of stainless steel and features a vent to atmosphere, which prevents inaccuracy typically associated with altitude changes. The sender unit remains accurate in all types of water and foam. The sender's electronics are encapsulated for protection from shock, vibration, water and dust.

WATR OAM OAM 10-LD Master Water Display P/N 3030358-01 10-LD Large Slave Water Display P/N 3030395-01 10-LD Master oam Display - Class A P/N 3030393-01A 10-LD Large Slave oam Display Class A P/N 3030396-01A 10-LD Master oam Display - Class B P/N 3030393-01B 10-LD Large Slave oam Display - Class B P/N 3030396-01B

WATR OAM 10-LD Master Dual Water/oam Display P/N 3030359-01 10-LD Dual Large Slave Water/oam Display P/N 3030397-01

OAM OAM 10-LD Dual Master oam Display - Class A & B P/N 3030394-01 10-LD Dual Large Slave oam Display - Class A & B P/N 3030398-01

To 12 Volt Supply OAM 6 Pin Slave Receptacle 10-LD Master oam Display P/N 3030393-01A Base-Mount Tank Sender P/N 3030376-01

1 Slave Display WATR To 12 Volt Supply WATR 2 Slave Displays WATR Y-Connector P/N 3030374 WATR 6 Pin Slave Receptacle 3 Slave Displays WATR WATR 10-LD Master Water Display P/N 3030358-01 WATR Base-Mount Tank Sender P/N 3030376-01

Monster Lights WATR +12 VDC Supply Monster Light Driver Module Gray +12 VDC Red 6 Pin Slave Receptacle Slave Connection P/N 3030362 Orange Blue White Green Brown Lamps: each 5 Amps Max @ 12 VDC Gray 10-LD Master Water Display P/N 3030358-01 Monster Lights Relay Driver Module P/N 3030362 Base-Mount Tank Sender P/N 3030376-01

WATR OAM OAM 14-LD Master Water Display P/N 3030385-01 14-LD Large Slave Water Display P/N 3030389-01 14-LD Master oam Display - Class A P/N 3030386-01A 14-LD Large Slave oam Display - Class A P/N 3030390-01A 14-LD Master oam Display - Class B P/N 3030386-01B 14-LD Large Slave oam Display - Class B P/N 3030390-01B

WATR OAM 14-LD Dual Master Water/oam Display P/N 3030387-01 14-LD Dual Large Slave Water/oam Display P/N 3030391-01

OAM OAM 14-LD Master Dual oam Display - Class A & B P/N 3030388-01 14-LD Dual Large Slave oam Display - Class A & B P/N 3030392-01

To 12 Volt Supply OAM 6 Pin Slave Receptacle 14-LD Master oam Display P/N 3030386-01 Base-Mount Tank Sender Unit P/N 3030376-01

1 Slave Display WATR To 12 Volt Supply WATR 2 Slave Displays WATR Y Connector P/N 3030374 WATR 6 Pin Slave Receptacle 3 Slave Displays WATR WATR 14-LD Master Water Display P/N 3030385-01 WATR Base-Mount Tank Sender P/N 3030376-01

Monster Lights WATR +12 VDC Supply Monster Light Driver Module +12 VDC Gray Red Lamps: each 5 Amps Max @ 12 VDC 6 Pin Slave Receptacle Slave Connection P/N 3030362 Orange Blue White Green Brown Gray 14-LD Master Water Display P/N 3030385-01 Monster Lights Relay Driver Module P/N 3030362 Base-Mount Tank Sender P/N 3030376-01

WATR OAM A OAM B 5-LD Mini Slave Water Display P/N 3030423-01 5-LD Mini Slave oam Display Class A P/N 3030423-01A 5-LD Mini Slave oam Display Class B P/N 3030423-01B WATR OAM OAM 5-LD Mini Slave Water Display P/N 3030372-01 5-LD Mini Slave oam Display Class A P/N 3030373-01A 5-LD Mini Slave oam Display Class B P/N 3030373-01B

langed Top-Mount Tank Sender P/N 3030448-01-XX Thread-Mount Tank Sender P/N 3030454-01-XX Master Display xtension Cable Base-Mount Tank Sender P/N 3030376-01

Vent tube to atmosphere prevents inaccuracy typically associated with altitude changes Heavy-Duty 18 Gauge wire in a jacketed shielded cable NPT Base-Mount Tank Sender IC P/N 3030376-01 Molded durable cable strain relief The easy-to-install sender unit is constructed of stainless steel and features a vent to atmosphere, which prevents inaccuracy typically associated with altitude changes. The sender unit remains accurate in all types of water and foam. The sender's electronics are encapsulated for protection from shock, vibration, water and dust. Sensor is encapsulated in a durable stainless steel housing Pressure sensor Orifice protected behind diaphragm. The sensor is protected from contact with the foam or water by a stainless steel diaphragm to prevent freeze-up and other sensor malfunctions related to exposure. Silicone film barrier A large bore allows the media to more easily flush and drain from the sensor housing, thereby preventing clogging caused by mineral deposits.

Master Display Y Connector 1 ft. P/N 3030374-01 3 ft. P/N 3030374-02 xternal Relay Warning Wire P/N XT Monster Light Driver Module Gray +12 VDC Red Lamps: each 5 Amps Max @ 12 VDC Monster Lights Driver Module P/N 3030362 P/N 3030349 Orange Slave Connection Blue White Wiring Harnesses 5 ft. P/N 4000418-01 10 ft. P/N 4000418-02 15 ft. P/N 4000418-03 20 ft. P/N 4000418-04 25 ft. P/N 4000418-05 30 ft. P/N 4000418-06 35 ft. P/N 4000418-07 40 ft. P/N 4000418-08 50 ft. P/N 4000418-09 P/N 3030362 Green Brown Gray

To Display To Sender SL Tester P/N 3030589 SL Tester System Hook-ups To SL Level Display P/N 3030349 To SL Sender Unit - - Voltmeter VDC Hook-ups Red(+) Black(-) Display Voltage Output Display Voltage Output Sender Signal Output Sender Signal Output + +

Slave Connection Gray Orange Blue White Green Brown +12 VDC Red Lamps: each 5 Amps Max @ 12 VDC Gray WATR WATR 1 Slave Display WATR WATR To 12 Volt Supply Plug installed when no slaves are used Display (Deutsch 6 socket) 1 - White (+12 VDC) 2 - Bare (Shield) 3 - Green () 4 - Blue (Reset) 5 - Red (Clock) 6 - Black (Data) 6 1 5 2 4 3 2 Slave Displays Y-Connector P/N 3030374 WATR 3 Slave Displays 10-LD Master Display P/N-3030358 6 Pin Slave Receptacle Systems with a single slave display plug directly into the master display. Systems with multiple slave displays, including mini displays and/or monster lights, utilize one or more Y-connectors to wire the network. +12 VDC Supply Monster Lights WATR WATR Sensor (Deutsch 6 pin) 1 - White (Signal +VDC) 2 - Bare (Shield) 1 6 3 - Vent 4 - Vent 2 5 5 - Red (+ 5VDC) 6 - Black (-) 3 4 Monster Light Driver Module P/N 3030362 Base-Mount Tank Sender P/N 3030376-01 Monster Lights Driver Module P/N 3030362

Note: This calibration procedure must be performed to ensure that the indicated fluid levels on the display accurately match the actual levels in the tank. The tank can be full or empty to begin calibration, but must be filled before beginning Step 4. To ensure proper calibration, do not have water in the fill tower. Step 1: Install Tank Sender Unit Step 2: Initiate Calibration Step 3: Calibrating The Probe Step 4: Tank Selection Mode To ensure proper drainage, it is highly recommended that the sender unit is mounted vertically on the side of the tank by using a 90 degree " NPT fitting. Connect sender unit to the display and the display to a 12 or 24 volt power source. Go to Step 2. TANK Within 1 min. of powering up the unit, place the magnet over the master display between the and levels. The,, and ULL lights will flash in succession and then they will flash together - at the same time. With the,, and ULL lights all flashing, fill tank - if not yet full. or a level-by-level calibration, do not fill tank and go to alt. instructions on page 2. ULL Place the magnet over the display between and levels. The level lights will flash in sequence upward beginning the tank selection mode. You will now select the tank shape. or a rectangular tank, go to Step 5. or a T tank, go to Step 6. or an elliptical tank go to Step 7. Step 5: Rectangular Tank Step 6: T-Shaped Tank Step 7: lliptical Tank Notes: When the level light begins to flash, place the magnet back onto the master display before the lights flash for the fifth time. When the level lights begin to flash, place the magnet back onto the master display before the lights flash for the fifth time. When the level lights begin to flash, place the magnet back onto the master display before the lights flash for the fifth time. If the magnet is not placed in front of the display to select a tank shape, the tank selection sequence will continue and the ULL light will flash 5 times. After the ULL light flashes 5 times the tank shape selection sequence will begin again. (Step 5) The tank shape selection sequence will repeat 3 times. If no tank shape selection is made in this time, the display will default to a rectangular tank. Remove the magnet. Calibration for a rectangular tank is now complete. If the magnet is not placed in time, wait until tank shape sequence begins again. Remove the magnet. Calibration for a T-shaped tank is now complete. If the magnet is not placed in time, wait until tank shape sequence begins again. Remove the magnet. Calibration for an elliptical tank is now complete. If the magnet is not placed in time, wait until tank shape sequence begins again. If the display was calibrated incorrectly, remove power from the display and repeat the process. Recalibration can not occur without cycling power. Calibration Instructions

Note: If none of the 3 calibration modes described on the previous page is acceptable, use this special calibration mode to set each of the water or foam levels independently. Perform Steps 1, 2, and 3 on previous page before starting Alt. Step 4. Alt. Step 4 Alt. Step 5 Alt. Step 6 Alt. Step 7 Alt. Step 8 With the tank empty and the,, and ULL lights flashing, place the magnet over the master display between the and levels. Wait until the ULL level is flashing and place the magnet over the display. ill the tank to the desired 25% level. Check level visually or by measuring depth. Place the magnet over the display. The lights will stay on while the lights begin to flash. ill the tank to the desired 50% level. Check level visually or by measuring depth. 50% The,,, and ULL lights will flash in succession. The and MPTY lights will alternate flashing. 25% Alt. Step 9 Alt. Step 10 Alt. Step 11 Alt. Step 12 Alt. Step 13 Place the magnet over the display. The and lights will be on while the lights begin to flash. ill the tank to the desired 50% level. Check level visually or by measuring depth. Place the magnet over the display. The, and lights will be on while the ULL lights begin to flash. ill the tank to the desired ULL level. Place the magnet over the display to complete the alternate calibration process. 100% 75% Calibration Instructions