McQuay. Console Water Source Heat Pump. Replacement Parts List No Revision Q 07/2016

Similar documents
McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1)

McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW Vintage B. WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS Design A (1)

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

Applied Decentralized Products Water Source Heat Pump / Rev.A HWH024D, HWH030D HWW024D, HWW030D PL

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

McQuay Climate Control Singer

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 3 009, 012 Design 4

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

McQuay Climate Control Singer. Water Source Heat Pump. VF, VG, VP Vintage C. Last Manufactured: 1982

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Thinline Vertical Fan Coil. FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay Singer Climate Control. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage C. Last Manufactured: 1990

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay Central Station Air Handler Medium Pressure MSL

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay. Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054. UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6)

FHP MANUFACTURING PARTS PRICE LIST

FHP MANUFACTURING PARTS PRICE LIST

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Parts. Package Terminal Air Conditioners. Models and manufacturing numbers in this manual. This Manual Replaces RP Rev. 3.

MDT5N25 & MTD5N40 SERVICE PARTS

Eclipse 2000 Service Parts

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay. Two-Stage Centrifugal Chiller WTC 500. Replacement Parts List No Revision A 10/2011

Prodigy Eclipse 600, 800, 1000 Service Parts

Hoshizaki America, Inc.

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

REPLACEMENT PARTS MANUAL

Parts List. Self-Contained Flaker. Models F-300BAF. hoshizakiamerica.com

SPLIT TYPE AIR CONDITIONER. CASSETTE type. Models Indoor unit Outdoor unit MC24Y3E

Parts List. Stackable Crescent Cuber. Models KM-1601SAH/3 KM-1601SWH/3 KM-1601SRH/3. hoshizakiamerica.com

Parts List. Stackable Crescent Cuber. Models KM-1601MRJ/3. hoshizakiamerica.com

Parts List. Self-Contained Cubelet. Models AM-50BAE AM-50BAE-DS AM-50BAE-AD AM-50BAE-ADDS. hoshizakiamerica.com

McQuay. Centrifugal Chiller WPV 320A - 350A. Last Manufactured: Replacement Parts List No Revision E 12/2017

Hoshizaki America, Inc.

KEY PART # DESCRIPTION KEY PART # DESCRIPTION

Parts List. Modular Crescent Cuber. Models KM-1340MAH, MWH, MRH/3. hoshizakiamerica.com

Product Manual C: Horizontal Water Source Heat Pumps Standard and Extended Range Unit Sizes 1 /2 to 10 Tons (1758 to Watts)

Hoshizaki America, Inc.

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

refrigeration SHAKE #15-77CMT ICE CREAM MACHINE ELECTRO FREEZE 21 SHAKE DISPENSE HEAD ASSEMBLY SHAKE BEATER SEAL ASSEMBLY 9

KEY PART # DESCRIPTION KEY PART # DESCRIPTION

Replacement Parts Catalog

Transcription:

Replacement Parts List 110502400 Revision Q 07/2016 McQuay Console Water Source Heat Pump WWAF,WWAG,WWAH,WWAS,WWAX,WWCQ WWDA,WWDB,WWDD,WWDE,WWDF,WWDG,WWDH, WWDJ,WWDN,WWDS,WWFQ,WWLA,WWLB,WWLC,WWLL, WWMA,WWMB,WWMC,WWMD,WWMF,WWMG,WWMH, WWMS,WWMT,WWMV,WWMX,WWMY,WWSQ Sizes 007, 009, 012, 015, 019 Design A (1) WWAA,WWAF,WWAG,WWAH,WWAS,WWAX, WWBL,WWBP,WWDA,WWDB,WWDC,WWDD,WWDE, WWDJ, WWDF, WWDG, WWDH, WWDL,WWDN,WWDS,WWDY, WWLA,WWLB,WWLC,WWLL,WWMA,WWMB,WWMC,WWMD, WWMF,WWMG,WWMH,WWMM,WWMN,WWMP,WWMQ, WWMS,WWMW,WWMX,WWMY,WWXB,WWXG Sizes 009, 012, 015, 019 Design B (2) To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Contents Parts List Revision History...3-4 Nomenclature Serial...5 Model...6 Fan and Housing Assembly Unit Sizes 007, 009, 012 Design A (Code 3= 1)...7 Unit Sizes 009, 012 Design B (Code 3= 2)...8 Unit Sizes 015, 019 Designs A and B (Code 3= 1, 2)...9 Electric Heat...10 Refrigeration Circuit Diagrams... 11 Compressors and Compressor Components Unit Sizes 007, 009, 012...12 Unit Sizes 015, 019...13 Evaporator, Plugs, Valves, and Switches Design A (Code 3= 1)...14 Design B (Code 3= 2)...15 Condenser - Coil and Tubing Design A (Code 3= 1)...16 Design B (Code 3= 2)...17 Control Box MicroTech Control Diagram...18 Components...19 Mark IV Controller Diagram...20 Components...21 Cabinet Flat Top Cabinet Diagram...22 Unit Sizes 007, 009, 012...23 Unit Sizes 015, 019... 24 Slope Top Cabinet Diagram...25 Unit Sizes 007, 009, 012...26 Unit Sizes 015, 019... 27 Subbase Diagram...28 Components...29 Chassis Panels...30 Field Installed Accessories...31-35 Critical Parts List Design A...CPL1 Design B... CPL2 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 2

Parts List Revision History Revision Date Description New 09/03 New A 03/05 Page 14 - Reversing Valve Solenoid Mark IV Controls with p/n 066541901 was incorrect, it has been changed to Reversing Valve Solenoid DC Mark IV Controls p/n 062298701. B 03/05 Page 33- High Sill Units table on bottom of page had incorrect heading. It changed from Unit Sizes 007, 009, 012 to 015,019. C 03/06 Page 7 - Deleted Honeywell information from Mark IV Unit Thermostats & Subbases and added Programmable with Remote Sensor Thermostat pn 106710801. Page 18 - Mount-Motor pn 056354202 was changed to 056354203. Page 19 - Mount-Motor pn 056354202 was changed to 056354203. Capacitor-Motor 5MFD deleted under unit size 012, 265/60/1 voltage. Capacitor-Motor 3MFD deleted under unit size 012, 208/60/1and 230/60/1 voltages. Page 23 - Relay-Electric Heat p/n 067180401 changed to 066803901. Page 26 - Bubbles 420, 421&424 heater relay p/n changed from 067180401 to 06680390. Page 32 - Added 1 note to bubble 601 Front Panel. D 04/06 Page 35 - Bub 712 pn changed from 061312502 to 061312402. E 08/06 Removed references to 'contact SMG Parts Tech' and replaced with 'contact McQuay Parts'. F 10/08 Page 12, 13 - Ref 101 Removed vendor #s on all. Page 22 - Ref 375 pn was 061321502 is now 061321501. Page 25 - Ref 377 Added DC to pn 056792401 Added Mark IV Board AC pn 056792402. G 10/08 Page 14, 15 - Added note for reversing valves. Page 25 - Ref 377 Added note for pn 056792401 and 056792402. H 10/09 Page 15- add "until 3/05" to reversing valve p/n 067284101 and solonoid p/n 066541901. Add footnote ** Mark IV Controls. I 10/09 Page 15- Add reversing valve 3/05 &later p/n 106694120. Add solonoid 3/05 & later p/n 106694202. J 10/09 Page 14-15 Add to reversing valve description "until 3/05" for p/n 067290301. Add reversing valve "3/05 and later" pn 106694120. Add to reversing valve solonoid description "until 3/05" for p/n 066541901. Add reversing valve solonoid "3/05 and later" pn 106694202. Add footnote change made 3/05 and later so the same component could be used for MicroTech and Mark IV units. K 01/10 Page 14-15 Change reversing valve "3/05 and later" p/n 106694120 to 106694102. L 2/12 Title page- Add WWDJ to models. Page 5- Add WWDJ to Nomenclature Code 1 & 2. Pages 14-15- Change rev. valve p/n 106694120 to 910110432 and p/n 106694102 to 910110418. Change rev. valve solenoid p/n 106694202 to 910110435. Pages 22, 23, 31, 32, 35- Add WWDJ to models. CPL1-2 Add Critical Parts List. M 7/13 Title Page- Add models- WWAA2,WWAF1,2,WWAG1,2,WWAH1,2,WWAS1,2,WWAX1,2, WWBL2,WWBP2,WWCQ1,WWDC2,WWDN1,2,WWDY2,WWFQ1,WWMT1,WWMV1,WWMW2, WWMX1,2,WWMY1,2,WWSQ1,WWXB2,WWXG2. Page 2- Contents, remove all model numbers update to page number changes. Page 4- Update Serial, February 199 & later to new format. Page 5- Code 1 & 2 -Add models(see above) and update all descriptions. Pages 11-17 Add Refrigeration Circuit to main heading. Page 14- Change Rev. Valve p/n 066807701 to 106694116, 067284101 to 106694120, and 066533701 to 106694102. Add Solenoid Mark IV p/ns 066541901 and 910110435. Add Solenoid MT2000 p/ns 066807802, 106694207 and 910110439. Page 21-22 Change title to MicroTech Control remove model numbers and consolidate pages. Page 23-24 Change title to Mark IV Controller remove model numbers and consolidate pages. Page 25- Change titles. Page 26-31 Change titles, delete models. Page 34 Consolidate all sizes to one page. CPL1-2 Change to CPL1 as Design A and CPL2 as Design B. N 2/15 Rebrand to Daikin. Title Page- Add models- WWDL 015 & WWMN 009, 012, 015. Page 5- Code 1 & 2 -Add models(see above) and update all descriptions. Page 14- Change footnote 5 from size 12 to size 15. CPL1-2 Rebrand CPL-master. O 3/15 Pages 22 & 24- Change Transformer 060630801 to 060630802. Delete 230/50V Transformer p/n 107502504. Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 3

Parts List Revision History Revision Date Description P 05/16 Rebrand Daikin. Page 24- Add condensate overflow switch p/n 056794401. Q 07/16 Numerous changes. Page 4- Add page for Parts List Revision History. Page 13- Add expansion valves part numbers 106697002 to 106697005. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 4

Nomenclature Serial Until February, 1999 7 9 A 00000 00 Plant Identification 7 = Auburn Year Manufactured 9 = 1999 A = January B = February C = March D = April E = May F = June Engineering Revision Serial Month Manufactured G = July I = August J = September K = October L = November M = December Serial February, 1999 & later AUB U 02 05 00148 Plant Identification Abbreviation AUB = Auburn Serial (build sequence) U= Unit Week of Manufacture Year of Manufacture 00= 2000 01= 2001 02= 2002 etc. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 5

Nomenclature Model WWLA 2 009 E Z 00 U 11 AA 14 A I Code: 1 & 2 3 4 5 6 7 8 9 10 11 12 13 1 & 2. Product Category & Product Identifier WWAA- WSHP-Flat Top Wall Mt, Alerton, Lo-Sil WWAF- WSHP-Flat Top Wall Mt, Alerton, Hi-Sil WWAG- WSHP-Slope Top Wall Mt, Alerton, Hi-Sil, Geothermal WWAH- WSHP-Slope Top Wall Mt, DDC Less Board, Hi-Sil, Geothemal WWAS- WSHP-Slope Top Wall Mt, Alerton, Hi-Sil WWAX- WSHP-Flat Top Wall Mt, Alerton, Hi-Sil, Geothermal WWBL- WSHP-Console, Lo-Sil WWBP- WSHP-Console, Geothermal WWCQ- WSHP-Slope Top Wall Mt, Mark IV, Lo-Sil, Chassis, Extra Quiet WWDA- WSHP-Flat Top Wall Mt, DDC, Lo-Sil, 60HZ WWDB- WSHP-Slope Top Wall Mt, DDC, Lo-Sil, 60HZ WWDC- WSHP-Flat Top Wall Mt, DDC, Hi-Sil, Chassis WWDD- WSHP-Slope Top Wall Mt, DDC, Hi-Sil, 60HZ WWDE- WSHP-Slope Top Wall Mt, DDC, Lo-Sil, 60HZ WWDF- WSHP-Flat Top Wall Mt, DDC, Hi-Sil, 60HZ WWDG- WSHP-Flat Top Wall Mt, DDC, Hi-Sil, 60HZ WWDH- WSHP-Slope Top Wall Mt, DDC, Hi-Sil, 60HZ WWDJ- WSHP-Slope Top Wall Mt, DDC Less Board, Lo-Sil, 60HZ WWDL- WSHP-Flat Top Wall Mt, DDC Less Board, Hi-Sil WWDN- WSHP-Slope Top Wall Mt, DDC, Hi-Sil, Chassis, Geothermal WWDS- WSHP-Slope Top Wall Mt, DDC, Hi-Sil, 60HZ WWDY- WSHP-Slope Top Wall Mt, DDC, Hi-Sil, Geothermal WWFQ- WSHP-Flat Top Wall Mt, Mark IV, Hi-Sil, Extra Quiet WWLA- WSHP-Slope Top Wall Mt, Mark IV, Hi-Sil, 60HZ WWLB- WSHP-Flat Top Wall Mt, Mark IV, Lo-Sil, 60HZ WWLC- WSHP-Slope Top Wall Mt, Mark IV, Lo-Sil, 60HZ WWLL- WSHP-Flat Top Wall Mt, Mark IV, Hi-Sil, 60HZ WWMA- WSHP-Slope Top Wall Mt, Mark IV, Lo-Sil, 60HZ WWMB- WSHP-Flat Top Wall Mt, Mark IV, Lo-Sil, 60HZ WWMC- WSHP-Flat Top Wall Mt, Mark IV, Hi-Sil, 60HZ WWMD- WSHP-Flat Top Wall Mt, Mark IV, Lo-Sil, 60HZ WWMF- WSHP-Flat Top Wall Mt, Mark IV, Hi-Sil WWMG- WSHP-Slope Top Wall Mt, Mark IV, Hi-Sil WWMH- WSHP-Slope Top Wall Mt, Mark IV, Lo-Sil WWMN- WSHP-Slope Top Wall Mt, Mark IV, Hi-Sil, Chassis, Geothermal WWMS- WSHP-Slope Top Wall Mt, Mark IV, Hi-Sil WWMT- WSHP-Flat Top Wall Mt, Mark IV, Hi-Sil, Chassis, Europe WWMV- WSHP-Flat Top Wall Mt, Mark IV, Lo-Sil, Chassis, Europe WWMW- WSHP-Flat Top Wall Mt, Mark IV, Lo-Sil, Geothermal WWMX- WSHP-Flat Top Wall Mt, Mark IV, Hi-Sil, Geothermal WWMY- WSHP-Slope Top Wall Mt, Mark IV, Hi-Sil, Geothermal WWSQ- WSHP-Slope Top Wall Mt, Mark IV, Lo-Sil, Extra Quiet WWXB- WSHP-Slope Top Wall Mt, Alerton, Lo-Sil, R-410A WWXG- WSHP-Flat Top Wall Mt, DDC Less Board, Hi-Sil, R-410A 3. Design (Vintage) 1= Design A 2= Design B (009, 012, 015, 019 only) 4. Size (1000's BTUH) 007, 009, 012, 015, 019 5. Unit Voltage A= 115/60/1 E= 208/230/60/1 J= 265/277/60/1 M= 230/50/1 6. Coil Options Z= None 7. Heating Options 00= None 20= 1.0 KW Electric Heat (sizes 007, 009, 012) 30= 2.0 KW Electric Heat (sizes 015, 019) 8. Hand Orientation V= Left Hand Piping Connection U= Right Hand Piping Connection 9. Controls 11= Unit Mounted ACO 12= Unit Mounted MCO 13= 24V Wall Thermostat 14= MT Tennant Set Point w/override 10. Discharge AA= Top Discharge 11. Return Air/ O.A. 14= Bottom 12. Power Connection A= Junction Box 13. Color I= Antique Ivory 14. SKU 15. Product Style 1= 1st Style Change WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 6

115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 Fan and Housing Assembly Unit Sizes 007, 009, 012 Design A (Code 3= 1) 007 009 012 Ref Description Specification Part N/S Motor, 1/60 HP 115/60/1 073388001 1 1 Motor, 1/60 HP 208/230/60/1 073388002 1 1 1 1 Motor, 1/60 HP 265/60/1 073388003 1 1 Motor, 1/60 HP 230/50/1 106087101 1 1 Motor, 1/24 HP 115/60/1 073384101 1 Motor, 1/24 HP 208/230/60/1 073384102 1 1 Motor, 1/24 HP 265/60/1 073384103 1 Motor, 1/40 HP 230/50/1 106069801 1 N/S Capacitor, 4MFD 370V until 6/09 067291502 1 1 Capacitor, 4MFD 370V 6/09 & later 669241501 1 1 Capacitor, 2MFD 370V 802007008 1 1 1 1 1 1 1 1 1 Capacitor, 5MFD 370V until 6/09 067291503 1 Capacitor, 5MFD 370V 6/09 & later 669241601 1 Capacitor, 3MFD 370V until 3/09 067291501 1 1 1 Capacitor, 3MFD 370V 3/09 & later 669241401 1 1 1 N/S Plug- Motor 2 Ckt. Plug 038254701 1 1 1 1 1 1 1 1 1 1 Plug- Motor 6 Ckt. Housing 047934203 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Fan Scroll 062550901 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Support- Fan Housing 056354301 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Mount- Motor 056354203 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Clip- Motor Mount 060900501 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 N/S Inlet Ring 062551001 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 Inlet Ring 062551101 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Fan Wheel 073383801 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Bracket- Capacitor 850010570 1 1 1 1 1 Boot- Capacitor 067291602 1 1 1 1 1 1 Protector- Capacitor 802007316 1 1 1 1 1 1 1 1 1 N/S Plate- Motor Heat Resistor 062502301 1 1 1 N/S Resistor- Motor 100 Watt 106087001 1 1 Resistor- Motor 100 Watt/ 300 OHM 106064701 1 N/S= Not shown on diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 7

115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 Fan and Housing Assembly Unit Sizes 009, 012 Design B (Code 3= 2) 009 012 Ref Description Specification Part N/S Motor, 1/24 HP 115/60/1 073384101 1 Motor, 1/24 HP 208/230/60/1 073384102 1 1 Motor, 1/24 HP 265/60/1 073384103 1 Motor, 1/60 HP 230/50/1 106087101 1 Motor, 1/15 HP 115/60/1 106433801 1 Motor, 1/15 HP 208/230/60/1 106433802 1 1 Motor, 1/15 HP 265/60/1 106433803 1 Motor, 1/40 HP 230/50/1 106069801 1 N/S Capacitor, 5MFD 370V until 6/09 067291503 1 1 6 1 9 1 9 Capacitor, 5MFD 370V 6/09 & later 669241601 1 1 1 1 Capacitor, 2MFD 370V 802007008 1 1 1 1 8 1 8 1 8 Capacitor, 3MFD 370V until 3/09 067291501 1 1 9 1 Capacitor, 3MFD 370V 309 & later 669241401 1 1 1 N/S Plug- Motor 6 Ckt. Housing 047934203 1 1 1 1 1 1 1 1 1 1 N/S Fan Scroll 062550901 1 1 1 1 1 1 1 1 1 1 N/S Support- Fan Housing 056354301 1 1 1 1 1 1 1 1 1 1 N/S Mount- Motor 056354203 1 1 1 1 1 1 1 1 1 1 N/S Clip- Motor Mount 060900501 2 2 2 2 2 2 2 2 2 2 N/S Inlet Ring 062551001 1 1 1 1 1 1 1 1 1 1 Inlet Ring 062551101 1 1 1 1 1 1 1 1 1 1 N/S Fan Wheel 073383801 1 1 1 1 1 1 1 1 1 1 N/S Bracket- Capacitor 850010570 1 1 1 Boot- Capacitor 067291602 1 1 1 1 1 1 1 Protector- Capacitor 802007316 1 1 1 N/S Plate- Motor Heat Resistor 062502301 1 1 N/S Resistor- Motor 100 Watt 106087001 1 Resistor- Motor 100 Watt/ 300 OHM 106064701 1 N/S= Not shown on diagram. 6 Until 11/02. 7 11/02 and later. 8 Until 2/02. 9 2/02 and later WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 8

208/60/1 230/60/1 265/60/1 230/50/1 208/60/1 230/60/1 265/60/1 230/50/1 Fan and Housing Assembly Unit Sizes 015, 019 Designs A and B (Code 3= 1, 2) 015 019 Ref Description Part N/S Motor, 1/8 HP 067782202 1 1 1 1 Motor, 1/8 HP 067782203 1 1 Motor, 1/8 HP 067782201 1 1 N/S Capacitor, 4MFD 370V until 6/09 067291502 1 1 1 1 1 1 Capacitor, 4MFD 370V 6/09 & later 669241501 1 1 1 1 1 1 Capacitor, 3MFD 370V until 6/09 067291501 1 1 Capacitor, 3MFD 370V 6/09 & later 669241401 1 1 N/S Plug- Motor 2 Ckt. Plug 038254701 1 1 1 1 1 1 1 1 Plug- Motor 6 Ckt. Plug Housing 047934203 1 1 1 1 1 1 1 1 N/S Fan Housing Assembly 11 061389101 2 2 2 2 2 2 2 2 Housing- Discharge 022930900 2 2 2 2 2 2 2 2 Housing- Access 022931000 2 2 2 2 2 2 2 2 Hub Clamp 066534601 2 2 2 2 2 2 2 2 N/S Support- Motor 056312801 1 1 1 1 1 1 1 1 N/S Bracket- Capacitor 802009019 1 1 1 1 1 1 1 1 N/S Clip- Motor Mount 060900501 2 2 2 2 2 2 2 2 N/S Capacitor Boot 1.5" Diameter 067291602 1 1 N/S= Not shown on diagram. 11 Includes housings, clamp, wheel, etc. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 9

Electric Heat 345 346 347 To Control Box Single Element- All Voltages Ref. Description Part 007 009 012 015 019 345 Heater 1.0 KW/ 265V 13 Code 7= 20 061409701 1 1 1 2.0 KW/ 265V 13 Code 7= 30 061409803 1 1 346 Limit Switch 1.0 KW Heater Code 7= 20 061402904 1 1 1 3.0 KW Heater Code 7= 30 061402903 1 1 347 Screw until 5/02 048440104 3 3 3 4 4 Screw 5/02 & later 4SBA2164 3 3 3 4 4 13 Heater Voltage. NOTE: Electric Heat is not available on 115V units. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 10

Refrigeration Circuit Diagrams 110 110 131 131 101 125 131 Control Box 105 102 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 11

115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 115/60/1 208/60/1 230/60/1 265/60/1 230/50/1 Refrigeration Circuit Compressors and Compressor Components Unit Sizes 007, 009, 012 007 009 012 Ref Description Part 101 Compr, 6670 BTUH 066531901 1 Compr, 6625 BTUH 066531902 1 1 Compr, 6625 BTUH 066531903 1 1 Compr, 9200 BTUH 061086003 1 Compr, 9100 BTUH 061086002 1 1 Compr, 9100 BTUH 061086001 1 1 Compr, 11700 BTUH 060907804 1 Compr, 11700 BTUH 060907801 1 1 Compr, 11700 BTUH 060907802 1 1 102 Capacitor, 35MFD 370V until 4/12 802007849 1 Capacitor, 35MFD 440V 4/12 & later 910120050 1 Capacitor, 15MFD 370V 802007844 1 1 Capacitor, 15MFD 440V until 4/12 802007852 1 Capacitor, 15MFD 440V 4/12 & later 910120046 1 Capacitor, 20MFD 370V 067291510 1 Capacitor, 25MFD 370V until 3/09 067291512 1 1 1 1 1 1 1 1 Capacitor, 25MFD 370V 3/09 & later 669450001 1 1 1 1 1 1 1 1 Capacitor, 25MFD 440V 802007855 1 1 105 Bracket- Capacitor 850010570 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 110 Locknut- Mounting until 12/01 032333302 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Locknut- Mounting 12/01 & later 063060601 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 125 Overload- Compressor 115/60/1 066536701 1 208/230/60/1 066536801 1 1 265/60/1 & 230/50/1 066536901 1 1 131 Mounting Sleeve until 5/00 067281401 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 Mounting Sleeve 5/00 & later 060623401 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 N/S Grommet- Compressor 060623301 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 N/S Capacitor- Boot 067291507 1 1 1 1 1 Capacitor- Boot 067291601 1 1 1 1 1 1 1 1 1 1 N/S Gasket- Compressor 066536601 1 1 1 1 1 N/S Gasket- Compressor 066537001 1 1 1 1 1 N/S Nut- Compressor 066536501 1 1 1 1 1 N/S Spring- Compressor 066536301 1 1 1 1 1 N/S Terminal Cover- Compressor 067280501 1 1 1 1 1 N/S= Not shown on diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 12

208/60/1 230/60/1 265/60/1 230/50/1 208/60/1 230/60/1 265/60/1 230/50/1 Refrigeration Circuit Compressors and Compressor Components Unit Sizes 015, 019 015 019 Ref Description Part 101 Compr, 15500 BTUH 061043401 1 1 Compr, 15500 BTUH 061043402 1 1 Compr, 17700 BTUH 066540301 1 1 Compr, 17500 BTUH 066540302 1 1 102 Capacitor, 25MFD 370V until 3/09 067291512 1 1 1 Capacitor, 25MFD 370V 3/09 & later 669450001 1 1 1 Capacitor, 25MFD 440V 802007855 1 1 1 1 1 105 Bracket- Capacitor 850010570 1 1 1 1 1 1 1 1 N/S Capacitor, Boot 067291601 1 1 1 1 1 1 1 1 110 Locknut- Mounting 063060601 3 3 3 3 3 3 3 3 131 Mounting Sleeve 060623401 3 3 3 3 3 3 3 3 N/S Grommet- Compressor 060623301 3 3 3 3 3 3 3 3 N/S= Not shown on diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 13

Refrigeration Circuit Evaporator, Plugs, Valves, and Switches Design A (Code 3= 1) Ref. Description Part 007 009 012 015 019 N/S Evaporator Coil until 2/03 056912202 1 Evaporator Coil 2/03 & later 056912203 1 Evaporator Coil 056912102 1 Evaporator Coil 056913503 1 Evaporator Coil 056912901 1 Evaporator Coil 056914101 1 N/S Strap- Evap. Coil L.H. Units (C08= V) only 056318801 1 1 1 N/S Extension- Evap. Header Plate 062578801 1 1 N/S Drain Pan- Evaporator 056374501 1 Drain Pan- Evaporator 056374502 1 1 Drain Pan- Evaporator 056374503 1 1 N/S Reversing Valve * until 3/05 066807701 1 1 Reversing Valve * 3/05 and later 106694116 1 1 Reversing Valve * until 3/05 067284101 1 Reversing Valve * 3/05 and later 106694120 1 Reversing Valve * until 3/05 066533701 1 1 Reversing Valve * 3/05 and later 106694102 1 1 N/S Solenoid, Reversing Valve * Mark IV Units until 3/05 062298701 1 1 1 1 1 Mark IV Units until 3/05 066541901 1 1 1 1 1 Mark IV Units 3/05 to 3/11 106694202 1 1 1 1 1 Mark IV Units 3/11 & later 910110435 1 1 1 1 1 MicroTech 2000 Units until 3/05 067010001 1 1 1 1 1 MicroTech 2000 Units until 3/05 066807802 1 1 1 1 1 MicroTech 2000 Units 3/05 to 3/11 106694207 1 1 1 1 1 MicroTech 2000 Units 3/11 & later 910110439 1 1 1 1 1 N/S Strainer 060628802 2 Strainer 060628808 1 Strainer 060628806 1 N/S Capillary 067290602 1 Capillary 067290601 1 Capillary 060634706 2 Capillary 060634739 2 5 Capillary 802001059 3 N/S Freezestat w/bulb 066540601 1 1 1 1 1 N/S Fusible Plug 106057401 1 1 1 1 1 N/S High Pressure Switch until 11/00 802005813 1 1 1 1 1 High Pressure Switch 11/00 & later 106035801 1 1 1 1 1 N/S Refrigerant Valve Assembly until 1/03 802026161 1 1 1 3 3 Refrigerant Valve Assembly 1/03 & later 802026161 2 2 2 2 2 N/S Muffler 047664306 1 1 N/S Discharge Line Weight 060746901 1 3 Discharge Line Weight 067009101 2 3 Discharge Line Weight Clip 50 Hz. (C05= M) 067009001 1 N/S Absorber- Vibration 50 Hz. (C05= M) 4FDX9002 1 1 1 Absorber- Vibration 50 Hz. (C05= M) 4FDX9003 1 1 5 Size 015 230/50/1 (code 5= M) units use capillary 802001059. * The new & old valves/solenoids are not compatible. If a new valve is ordered to replace an old style valve, a new solenoid coil must also be ordered. Refer to Ranco Reversing Valve Form 571039. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 14

Refrigeration Circuit Evaporator, Plugs, Valves, and Switches Design B (Code 3= 2) Ref. Description Part 009 012 015 019 N/S Evaporator Coil 60 Hz. Units (C05= A, E, J) 106433301 1 Evaporator Coil 50 Hz. Units (C05= M) 056912102 1 Evaporator Coil 60 Hz. Units (C05= A, E, J) 106434201 1 Evaporator Coil 50 Hz. Units (C05= M) 056913503 1 Evaporator Coil 106434601 1 Evaporator Coil 056914101 1 N/S Strap- Evap. Coil L.H. Units (C08= V) only 056318801 1 1 N/S Extension- Evap. Header Plate 062578801 1 1 N/S Drain Pan- Evaporator 056374502 1 1 N/S Drain Pan- Evaporator 056374503 1 1 N/S Reversing Valve * until 3/05 066807701 1 Reversing Valve * 3/05 & later 106694116 1 Reversing Valve * until 3/05 067284101 1 Reversing Valve * 3/05 & later 106694120 1 Reversing Valve * until 3/05 066533701 1 1 Reversing Valve * 3/05 & later 106694102 1 1 N/S Solenoid, Reversing Valve * Mark IV Units until 3/05 062298701 1 1 1 1 Mark IV Units until 3/05 066541901 1 1 1 1 Mark IV Units 3/05 to 3/11 106694202 1 1 1 1 Mark IV Units 3/11 & later 910110435 1 1 1 1 MicroTech 2000 Units until 3/05 067010001 1 1 1 MicroTech 2000 Units until 3/05 066807802 1 1 1 1 All Units 3/05 to 3/11 106694207 1 1 1 1 All Units 3/11 & later 910110439 1 1 1 1 N/S Strainer 060628802 1 Strainer 060628808 1 Strainer 060628806 1 N/S Capillary 067290601 1 Capillary 060634706 2 Capillary 060634739 2 5 Capillary 802001059 3 N/S Freezestat w/bulb 066540601 1 1 1 1 N/S Fusible Plug 106057401 1 1 1 1 N/S High Pressure Switch 106035801 1 1 1 1 N/S Refrigerant Valve Assembly until 1/03 802026161 1 1 1 3 Refrigerant Valve Assembly 1/03 & later 802026161 2 2 2 2 N/S Muffler 047664306 1 1 N/S Discharge Line Weight 060746901 3 Discharge Line Weight 067009101 2 3 Discharge Line Weight Clip 50 Hz. (C05= M) 067009001 1 N/S Absorber- Vibration 50 Hz. (C05= M) 4FDX9002 1 1 Absorber- Vibration 50 Hz. (C05= M) 4FDX9003 1 1 N/S Expansion Valve 106697002 1 Expansion Valve 106697003 1 Expansion Valve 106697004 1 Expansion Valve 106697005 1 5 Size 012 230/50/1 (code 5= M) units use capillary 802001059. * The new & old valves/solenoids are not compatible. If a new valve is ordered to replace an old style valve, a new solenoid coil must also be ordered. Refer to Ranco Reversing Valve Form 571039. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 15

Refrigeration Circuit Condenser- Coil and Tubing Design A (Code 3= 1) Left-hand Configuration 174 173 172 Right-hand Configuration 227 173 171 174 174 172 227 171 174 Ref. Description Specification Part 007 009 012 015 019 171 Condenser Copper Inner Tube 073394401 1 Condenser Copper Inner Tube 073394501 1 Condenser Copper Inner Tube 073394601 1 Condenser Copper Inner Tube 073380301 1 1 172 Tube- Inlet: LH Unit C06= L 061417801 1 1 1 Tube- Inlet: LH Unit C06= L 061418201 1 1 Tube- Inlet: RH Unit C06= R 061418001 1 1 1 Tube- Inlet: RH Unit C06= R 061418401 1 1 173 Tube- Outlet: LH Unit C06= L 061417701 1 1 1 Tube- Outlet: RH Unit C06= L 061418101 1 1 Tube- Outlet: LH Unit C06= R 061417901 1 1 1 Tube- Outlet: RH Unit C06= R 061418301 1 1 174 Tube Coupling 041116508 2 2 2 227 Tube- Condenser to Strainer 056353101 1 Tube- Condenser to Strainer 056373001 1 Tube- Condenser to Strainer 056387201 1 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 16

Refrigeration Circuit Condenser- Coil and Tubing Design B (Code 3= 2) Left-hand Configuration 174 173 172 Right-hand Configuration 227 173 171 174 174 172 227 171 174 Ref. Description Specification Part 007 009 012 015 019 171 Condenser Copper Inner Tube 073394401 1 Condenser Copper Inner Tube 073394501 1 Condenser Copper Inner Tube 073394601 1 Condenser Copper Inner Tube 073380301 1 Condenser Copper Inner Tube 073380303 1 172 Tube- Inlet: LH Unit C06= L 061417801 1 1 1 Tube- Inlet: LH Unit C06= L 061418201 1 Tube- Inlet: LH Unit C06= L 061418202 1 Tube- Inlet: RH Unit C06= R 061418001 1 1 1 Tube- Inlet: RH Unit C06= R 061418401 1 Tube- Inlet: RH Unit C06= R 061418402 1 173 Tube- Outlet: LH Unit C06= L 061417701 1 1 1 Tube- Outlet: RH Unit C06= L 061418101 1 Tube- Outlet: RH Unit C06= L 061418102 1 Tube- Outlet: LH Unit C06= R 061417901 1 1 1 Tube- Outlet: RH Unit C06= R 061418301 1 Tube- Outlet: RH Unit C06= R 061418302 1 174 Tube Coupling 041116508 2 2 2 227 Tube- Condenser to Strainer 056353101 1 Tube- Condenser to Strainer 056373001 1 Tube- Condenser to Strainer 056387201 1 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 17

Control Box MicroTech Control Diagram 376 387 375 362 391 385 442 441 367 373 369 370 429 226 435 450 377 226 227 227 Transformer Detail WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 18

Control Box MicroTech Control Components Ref. Description Part Voltage 208/60 230/60 265/60 230/50 226 Transformer until 3/01 060614101 1 1 1 Transformer 3/01 & later 060614102 1 1 1 Transformer until 3/01 060630701 1 Transformer 3/01 & later 060630702 1 227 Terminal- Quick Connect 803007156 4 4 3 362 Top Panel Flat Top Units 056919689 1 1 1 1 Top Panel Slope Top Units 056919789 1 1 1 1 367 End Panel- Flat Top 061353399 1 1 1 1 End Panel- Slope Top 061304099 1 1 1 1 369 Snap in Bushing 049751907 1 1 1 1 370 Terminal Board 802007090 1 1 1 1 373 Potentiometer 062596401 1 1 1 1 375 Rocker Switch 061321501 1 1 1 1 376 Knob 066544601 1 1 1 1 377 PC Board Main Controller MicroTech 2000 until 4/09 073312501 1 1 1 1 MicroTech 2000 4/09 to 2/11 073312502 1 1 1 1 MicroTech 2000 2/11 to 9/12 073312504 1 1 1 1 MicroTech 2000 9/12 & later 250808401 1 1 1 1 385 Switch- 2 Button 061348801 1 1 1 1 387 Overlay- Control Plate Code 9= 14 061381801 1 1 1 1 Code 9= 13 061381901 1 1 1 1 391 Switch- Momentary N.O. 061377201 1 1 1 1 429 Control Box Bottom 061300299 1 1 1 1 435 Split Bushing 061377301 1 1 1 1 441 Terminal Block 4 Terminals 065499804 1 1 1 1 442 Resistor- 1000 OHM 044690110 1 1 1 1 450 Relay- Fan 24V 047356506 1 1 1 1 N/S Terminal Block Lo Volt 073315201 1 1 1 1 N/S Terminal Block ELUPC 061365602 1 1 1 1 N/S Relay- Electric Heat 2PDT 066803901 3 3 3 2 N/S Air Sensor until 2/00 073305601 2 2 2 2 Air Sensor (DAT & RAT) 2/00 & later 107201601 2 2 2 2 N/S Water Sensor until 2/00 073305701 2 2 2 2 Water Sensor (EWT & LWT) 2/00 & later 107201601 2 2 2 2 N/S Junction Box Connection Junction Box 802007362 1 1 1 Junction Box 802007867 1 Junction Box Cover 000127300 1 1 1 Junction Box Cover 000969300 1 Terminal Block Medium Duty 802007432 3 End Block 802007431 1 N/S= Not shown on diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 19

Control Box Mark IV Controller Diagram Ref# 387 Overlay Detail 061356901 061381801 061381901 376 375 387 391 399 401 362 385 398 366 367 403 373 369 370 426 430 420 421 424 432 389 390 264 377 423 429 378 435 435 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 20

Control Box Mark IV Controller Components Ref. Description Part Voltage 115/60 208/60 230/60 265/60 230/50 264 Transformer until 3/01 060630801 1 Transformer 3/01 and later 060630802 1 Transformer until 3/01 060614101 1 1 1 Transformer 3/01 and later 060614102 1 1 1 Transformer until 3/01 060630701 1 Transformer 3/01 and later 060630702 1 362 Top Panel- Flat Top 106056789 1 1 1 1 1 Top Panel- Slope Top 106056889 1 1 1 1 1 366 Plate- Thermostat 106056401 1 1 1 1 1 367 End Panel- Flat Top 061353399 1 1 1 1 1 End Panel- Slope Top 061304099 1 1 1 1 1 369 Snap In Bushing 023251700 1 1 1 1 1 370 Terminal Board 802007090 1 1 1 1 1 373 Temp. Control straps on tube Auto Changeover Units C09= 11 066540802 1 1 1 1 1 Manual Changeover Units C09= 12 062278701 1 1 1 1 1 375 Rocker Switch 061321501 1 1 1 1 1 376 Knob 061334001 1 1 1 1 1 377 PC Board Main Controller Mark IV DC ** 056792401 1 1 1 1 1 Mark IV AC ** 056792402 1 1 1 1 1 378 Stand Off 7/17" 802028115 5 5 5 5 5 385 Switch- 2 Button C09= 11 or 13 061348801 1 1 1 1 1 Switch- 4 Button C09= 12 061317701 1 1 1 1 1 387 Overlay- Control Plate Code 9= 11 061381801 1 1 1 1 1 Overlay- Control Plate Code 9= 12 061356901 1 1 1 1 1 Overlay- Control Plate Code 9= 13 061381901 1 1 1 1 1 389 Low Temp. Control C09= 11 061400701 1 1 1 1 1 390 Screw 048448102 2 2 2 2 2 391 Switch, Momentary C09= 11 061377201 1 1 1 1 1 398 Junction Box 802007362 1 1 1 1 Junction Box 802007867 1 399 Junction Box Cover 000127300 1 1 1 1 Junction Box Cover 000969300 1 401 Snap In Bushing 049751907 1 1 1 1 1 403 Cup Washer 4WEA6586 1 1 1 1 1 420 Heater Relay 24V 2PDT 066803901 1 1 1 1 1 421 Heater Relay 24V 2PDT 066803901 1 1 1 1 1 423 Bracket- Night Setback Code 9= 11 061397701 1 1 1 1 1 424 Heater Relay 24V 1PDT 066803901 1 1 1 1 426 Receptacle 15 Circuits 034621900 1 1 1 1 1 429 Bottom Panel 061300299 1 1 1 1 1 430 Rocker Switch SPDT 047357307 1 1 1 1 1 432 Terminal Block 061365602 1 1 1 1 1 435 Bushing 061377301 1 1 1 1 1 N/S Low Temperature- Electric Heat SPDT 061350201 1 1 1 1 1 N/S Condensate Overflow Switch 056794401 1 1 1 1 1 NOTE: Code 9= 11 applies to all WWL* units. Code 9= 12 (unit mtd.) and Code 9= 13 (remote) apply to WWM* units. ** When replacing reversing valve and/or coil refer to Service Bulletin WS-SB-20070423. N/S= Not Shown on Diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 21

Cabinet Flat Top Diagram 653 652 651 Door oriented for left hand piping unit. Door oriented for right hand piping unit. 603 604 601 663 602 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 22

Cabinet Flat Top Unit Sizes 007, 009, 012 Ref. Description Part Qty. 601 Front Panel 061327799 1 602 Left End Panel 061327990 1 603 Right End Panel 061328090 1 604 Tie Piece 061328199 1 651 Grille 061301102 1 652 Door Frame 061301402 1 653 Door 061301302 1 663 Blockoff (LH Unit Only Code 8= V) 061363802 1 N/S Gasket 106088101 2 N/S Insulation- Felt 061398501 2 N/S= Not Shown on Diagram. Low Sill Units High Sill Units Ref. Description Part Qty. 601 Front Panel 061327599 1 602 Left End Panel 061327990 1 603 Right End Panel 061328090 1 604 Tie Piece 061328199 1 651 Grille 061301102 1 652 Door Frame 061301402 1 653 Door 061301302 1 663 Blockoff (LH Unit Only Code 8= V) 061363802 1 N/S Gasket 106088101 2 N/S Insulation- Felt 061398501 2 N/S= Not Shown on Diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 23

Cabinet Flat Top Unit Sizes 015, 019 Ref. Description Part Qty. 601 Front Panel 061327899 1 602 Left End Panel 061327990 1 603 Right End Panel 061328090 1 604 Tie Piece 061328299 1 651 Grille 061301202 1 652 Door Frame 061301402 1 653 Door 061301302 1 663 Blockoff (LH Unit Only Code 8= V) 061363802 1 N/S Gasket 106088101 2 N/S Insulation- Felt 061398501 2 N/S= Not Shown on Diagram. Low Sill Units Ref. Description Part Qty. 601 Front Panel 061327699 1 602 Left End Panel 061327990 1 603 Right End Panel 061328090 1 604 Tie Piece 061328299 1 651 Grille 061301202 1 652 Door Frame 061301402 1 653 Door 061301302 1 663 Blockoff (LH Unit Only Code 8= V) 061363802 1 N/S Gasket 106088101 2 N/S Insulation- Felt 061398501 2 N/S= Not Shown on Diagram. High Sill Units WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 24

Cabinet Slope Top Diagram 652 653 Door oriented for left hand piping unit. 651 Door oriented for right hand piping unit. 663 603 601 604 602 656 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 25

Cabinet Slope Top Unit Sizes 007, 009, 012 Low Sill Units Ref. Description Part Qty. 601 Front Panel 1 061329499 1 602 Left End Panel 061355102 1 603 Right End Panel 061355002 1 604 Tie Piece 061303799 1 651 Grille until 11/99 061356402 4 Grille 11/99 & later 107903901 4 652 Door Frame until 11/99 061356602 1 Door Frame 11/99 & later 105538901 1 653 Door until 11/99 061356702 1 Door 11/99 & later 105539001 1 656 End Cap until 11/99 061356502 1 End Cap 11/99 & later 107904001 1 663 Blockoff- L.H. Units only (C06= L) 061302302 1 1 Front Panel with corrosion Resistant Antique Ivory Paint, p/n 106449400. High Sill Units Ref. Description Part Qty. 601 Front Panel 061300899 1 602 Left End Panel 061355102 1 603 Right End Panel 061355002 1 604 Tie Piece 061303799 1 651 Grille until 11/99 061356402 4 Grille 11/99 & later 107903901 4 652 Door Frame until 11/99 061356602 1 Door Frame 11/99 & later 105538901 1 653 Door until 11/99 061356702 1 Door 11/99 & later 105539001 1 656 End Cap until 11/99 061356502 1 End Cap 11/99 & later 107904001 1 663 Blockoff- L.H. Units only (C06= L) 061302302 1 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 26

Cabinet Slope Top Unit Sizes 015, 019 Low Sill Units Ref. Description Part Qty. 601 Front Panel 061328399 1 602 Left End Panel 061355102 1 603 Right End Panel 061355002 1 604 Tie Piece 061312099 1 651 Grille until 11/99 061356402 5 Grille 11/99 & later 107903901 5 652 Door Frame until 11/99 061356602 1 Door Frame 11/99 & later 105538901 1 653 Door until 11/99 061356702 1 Door 11/99 & later 105539001 1 656 End Cap until 11/99 061356502 1 End Cap 11/99 & later 107904001 1 663 Blockoff- L.H. Units only (C06= L) 061302302 1 High Sill Units Ref. Description Part Qty. 601 Front Panel 061312199 1 602 Left End Panel 061355102 1 603 Right End Panel 061355002 1 604 Tie Piece 061312099 1 651 Grille until 11/99 061356402 5 Grille 11/99 & later 107903901 5 652 Door Frame until 11/99 061356602 1 Door Frame 11/99 & later 105538901 1 653 Door until 11/99 061356702 1 Door 11/99 & later 105539001 1 656 End Cap until 11/99 061356502 1 End Cap 11/99 & later 107904001 1 663 Blockoff- L.H. Units only (C06= L) 061302302 1 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 27

Subbase Diagram 605 Subbase frame shown in left hand piping position. 711 Subbase frame shown in right hand piping position. 712 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 28

Subbase, Back Panel Components Unit Sizes- 007, 009, 012 High Sill Units Ref. Description Unit Unit Piping Part Qty. Voltage Hand 605 Back Panel All Either 106089990 1 711 Subbase Frame 115/208/230/265/60 Either 061300502 1 Subbase Frame 230/50 Either 062510190 1 712 Subbase Panel 115/208/230/265/60 Either 061305202 1 Subbase Panel 230/50 LH 056383190 1 Subbase Panel 230/50 RH 056383191 1 N/S Throwaway Filter All Either 061302503 1 Unit Sizes- 007, 009, 012 Low Sill Units Ref. Description Unit Unit Piping Part Qty. Voltage Hand 605 Back Panel All Either 106089990 1 711 Subbase Frame 115/208/230/265/60 LH 061328402 1 Subbase Frame 115/208/230/265/60 RH 062506301 1 Subbase Frame 230/50 LH 062506302 1 Subbase Frame 230/50 RH 062506301 1 N/S Throwaway Filter All Either 061302503 1 Unit Sizes- 015, 019 High Sill Units Ref. Description Unit Unit Piping Part Qty. Voltage Hand 605 Back Panel All Either 106090090 1 711 Subbase Frame 208/230/265/60 Either 061472604 1 Subbase Frame 230/50 Either 062510290 1 712 Subbase Panel 208/230/265/60 Either 061312402 1 Subbase Panel 230/50 LH 056383190 1 Subbase Panel 230/50 RH 056383191 1 N/S Throwaway Filter All Either 061302502 1 N/S= Not Shown on Diagram. Unit Sizes- 015, 019 Low Sill Units Ref. Description Unit Unit Piping Part Qty. Voltage Hand 605 Back Panel All Either 106090090 1 711 Subbase Frame 208/230/265/60 LH 061328502 1 Subbase Frame 208/230/265/60 RH 061376602 1 Subbase Frame 230/50 LH 062506303 1 Subbase Frame 230/50 RH 062506304 1 N/S Throwaway Filter All Either 061302504 1 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 29

Chassis Panels Components Ref. Description Part Qty. N/S Basepan Unit Sizes 007, 009, 012 056360901 1 Unit Sizes 015, 019 056360910 1 N/S Left Panel Flat Top Units 056360711 1 Left Panel Slope Top Units 056360712 1 N/S Right Panel 056361713 1 N/S Center Panel Flat Top 056361513 1 Center Panel Slope Top 056361516 1 N/S Coil Mount Unit Sizes 007, 009, 012 056371101 1 Unit Sizes 015, 019 056371102 1 N/S Control Access Flat Top 056361813 1 Control Access Slope Top 056361814 1 N/S Fan Cover Panel Unit Sizes 007, 009, 012 Flat Top/ High Sill 056361915 1 Unit Sizes 015, 019 Flat Top/ High Sill 056361905 1 Unit Sizes 007, 009, 012 Slope Top/High Sill 056361917 1 Unit Sizes 015, 019 Slope Top/High Sill 056361907 1 Unit Sizes 007, 009, 012 Flat Top/Low Sill 056361916 1 Unit Sizes 015, 019 Flat Top/Low Sill 056361906 1 Unit Sizes 007, 009, 012 Slope Top/ Low Sill 056361918 1 Unit Sizes 015, 019 Slope Top/ Low Sill 056361908 1 N/S Water Tube Retainer Clip 061304501 1 N/S Filter Support Low Sill units only 061300601 2 N/S Gasket- 1/8" X 3/8" X 156" Low Sill units only 062964001 1 N/S Back Panel Assembly 14 Unit Sizes 007, 009, 012 230/50/1 056369201 1 Unit Sizes 015, 019 230/50/1 056369203 1 Unit Sizes 007, 009, 012 115/208/230/265/60/1 058955801 1 Unit Sizes 015, 019 115/208/230/265/60/1 061311699 1 N/S= Not Shown on Diagram. 14 Includes condenser access and evaporator baffle. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 30

Field Installed Accessories Fuse & Disconnect with Cordset 692 691 700 694 698 699 693 702 Ref. Description Specification Part 208/ 265V 230V Kit 061472701 1 Kit 061472702 1 691 Disconnect Box 061360901 1 1 692 Bracket 061361201 1 1 693 Cover 061361101 1 1 694 Panel 061361001 1 1 698 Fuse Holder 802007553 1 1 699 Fuse 15A 049128306 1 1 700 Receptacle 047139805 1 N/A 702 Switch 061350601 1 1 N/S Cord Set 062218102 1 Cord Set 062218104 1 N/S= Not Shown on Diagram. N/A= Not Applicable. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 31

208/60/1 230/60/1 265/60/1 Field Installed Accessories Continued 808 Manual Outside Air Damper 803 Ref. Description Part Qty. Kit 107942601 803 Damper Box 061453101 1 805 Actuator 061450601 1 808 Damper Door 061442999 1 N/S Gasketing 107942501 2 N/S Gasketing 107942502 2 N/S= Not Shown on Diagram. 805 Motorized Outside Air Damper 808 829 817 813 803 810 806 825 Ref. Description Specification Part 208V Kit 106066901 1 230V Kit 106066801 1 265V Kit 106066701 1 803 Damper Box 061453189 1 1 1 806 Wire Box 061443002 1 1 1 808 Damper Door 061442999 1 1 1 810 Damper Motor 115V Units 802024015 1 Damper Motor 208V Units 850003960 1 Damper Motor 230V Units 850003962 1 813 Operating Arm 062968001 1 1 1 817 Spring- Extension 802017209 1 1 1 825 Toggle Switch 802005045 1 1 1 829 Door Link 802023021 1 1 1 N/S Gasketing 107942501 2 2 2 N/S Gasketing 107942502 2 2 2 N/S= Not Shown on Diagram. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 32

Field Installed Accessories Continued Subbase Kits- Chassis Only High Sill Units WWDD, WWMC, & WWMG Units Description Right Hand Left Hand Sizes 007, 009, 012 061472602 061472601 Sizes 015, 019 061472604 061472603 Duct Collar Kit- Chassis Only Units WWDD, WWDE, WWMC, WWMD, WWMG, WWMH Description 007, 009, 012 015, 019 Duct Collar Kit 106061501 106061601 Duct Collar Only 061448801 061448901 Gasket 061343960 061343960 Cabinet/Subbase/Backwrap Replacement Kits 4 Description Unit Sizes Top Sill Piping Hand Part Cabinet/Subbase/Backwrap Kit 007, 009, 012 Flat Low Right 107231701 Cabinet/Subbase/Backwrap Kit 007, 009, 012 Flat Low Left 107231801 Cabinet/Subbase/Backwrap Kit 007, 009, 012 Flat High Right 107215801 Cabinet/Subbase/Backwrap Kit 007, 009, 012 Flat High Left 107215001 Cabinet/Subbase/Backwrap Kit 007, 009, 012 Slope Low Right 107230901 Cabinet/Subbase/Backwrap Kit 007, 009, 012 Slope Low Left 107231001 Cabinet/Subbase/Backwrap Kit 007, 009, 012 Slope High Right 107228201 Cabinet/Subbase/Backwrap Kit 007, 009, 012 Slope High Left 107231501 Cabinet/Subbase/Backwrap Kit 015, 019 Flat Low Right 107231901 Cabinet/Subbase/Backwrap Kit 015, 019 Flat Low Left 107232001 Cabinet/Subbase/Backwrap Kit 015, 019 Flat High Right 107215101 Cabinet/Subbase/Backwrap Kit 015, 019 Flat High Left 107215201 Cabinet/Subbase/Backwrap Kit 015, 019 Slope Low Right 107231101 Cabinet/Subbase/Backwrap Kit 015, 019 Slope Low Left 107231201 Cabinet/Subbase/Backwrap Kit 015, 019 Slope High Right 107231601 Cabinet/Subbase/Backwrap Kit 015, 019 Slope High Left 107230801 4 Individual components are listed in the Cabinet and Subbase Sections in the RPL. WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 33

Continued Relays Description Part Auxiliary Relay 061019403 24V, Normally Open. Used with WCDL & WCDS Units. Dry Contact Relay 5 VDC in; AC/DC out, Normally Open, SPST. Replaces the standard 24V relays in the 049265603 MicroTech panel. Used with WCDL & WCDS Units. Motorized Valve Control Relay Kit Used on WCMS units with Motorized Valve. Kit contains circuit board 859004354 p/n 803005073 and 6-pin plug p/n 061370301. Pump Restart Relay Used on Mark IV units (WCMS) in conjunction w/ LWC to restart when compressor 061419001 starts. One relay required per 200 units along a 2-wire daisy chain. Time Schedule Relay. 24 VDC relay controls the Mark IV (WCMS) "U" terminal. One required per time 049265602 clock output. Replaces 24 VAC relay. Ball Valves and Motorized Valves Description Part Combination Shutoff/Balancing Valve with Memory Stop (2 per unit) 802026097 Motorized Valve Kit 1 060977401 Includes valve/operator, conduit assy. Valve shuts water flow off. 300 PSIG max. 1 Requires Motorized Valve control relay (see relays above). Field Installed Accessories Hoses Description Specification Part Fire- Rated Rubber Supply/Return Hoses. Steel Braided 9" long, 1/2" I.D. 061269011 hose with one MPT and one MPT swivel fitting. 2 per unit. 12" long, 1/2" I.D. 061269007 18" long, 1/2" I.D. 061269008 Filters Description Unit Size Specification Part Throwaway Filter 007-012 High Sill 061302501 007-012 Low Sill 061302503 015, 019 High Sill 061302502 015, 019 Low Sill 061302504 Immersion Sensor, Thermostat Guard Description Part Immersion Sensor 049763201 Thermostat Guard 105571103 Honeywell TG12A 1009. Clear plastic guard with ring base, lock and key. Elbow Kit Description Specification Part Added to the End of Supply & Return Piping ½" X ½" 061435301 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 34

MicroTech Wall- Mounted Room Sensors Description Part Sensor w/ LED, Tenant Override 073302301 Sensor w/ LED, Tenant Override, Tenant Setpoint 073302901 Sensor w/ LED, Tenant Override, Thermostat 073302401 Sensor w/ LED, Tenant Override, Tenant Setpoint, Thermostat 073303001 Description Specification Part Master/Slave Control Board Master & 1 Slave 803005159 Auxiliary Relay 24 VDC 803005073 Description Specification Part Heat Pump Loop Installation Kit Controls Main Water Loop Temp. Includes Flow Switch p/n 046499800, 055331701 Immersion Sensor 049763201, O.A. Sensor p/n 049763301. Open Lower Loop Installation Kit Controls Main Water Loop Temp. Includes Flow Switch p/n 046499800, 055331702 Immersion Sensor 049763201. Loop Water Control Panel 2 LWC16 w/modem 066005213 Provides 9 (LWC16) or 17 (LWC24) outputs for heat rejection and heat LWC16 no modem 066005211 addition stages and time clock (6 max.) schedules. LWC24 w/modem 066005214 LWC24 no modem 066005212 Remote Alarm Panel 3 Monitors LWC Panel Status. 055335401 2 See RPL 0555234900 for complete LWC panel parts list. 3 Panel components listed below. Mark IV Unit Control Accessories Mark IV Unit Thermostats and Subbases Description Part Thermostat Standard MCO 105570703 Subbase- Standard MCO 073319501 Thermostat and Subbase- Deluxe ACO w/ NSB & OR 105571003 Thermostat and Wallplate- Electronic, Non-Programmable 107210201 Thermostat and Wallplate- Electronic, Programmable 107210301 Thermostat,Programmable with Remote Sensor 106710801 300 Field Installed Accessories Continued Heat Pump Loop Installation Kits and Control Panels Remote Alarm Panel Detail (RAP) 301 303 302 304 Ref. Description Part Qty. 300 Electrical Box 065812601 1 301 Switch- Silence 065812501 1 302 LED- Red 065810801 1 303 Horn- Alarm 065810901 1 304 LED- Yellow 065810803 1 WSHP; WWA*,WWB*,WWC*,WWD*,WWF*,WWL*,WWM*,WWS*,WWX* Sizes 007-019A/009-019B Rev. Q 07/16 RPL 1105024 / Page 35

Critical Daikin Applied OEM Parts Are What Your Daikin Applied HVAC Unit Needs! Console WSHP WWA*,WWC*,WWD*,WWF*,WWL*, WWM*, WWS* Sizes 007-019 Design A (1) CRITICAL PART COMPONENTS MODEL UNIT SIZE VOLTAGE NUMBER CONTROLS Mark IV DC ALL ALL N/A 056792401 Mark IV AC ALL ALL N/A 056792402 MicroTech 2000 WWD*, WWX* ALL N/A 250808401 Alerton WWA* ALL N/A 106393501 COMPRESSOR Compr, 6670 BTU ALL 007 115/60/1 066531901 Compr, 6625 BTU ALL 007 208/230/60/1 066531902 Compr, 6625 BTU ALL 007 265/60/1 & 230/50/1 066531903 Compr, 9200 BTU ALL 009 115/60/1 061086003 Compr, 9100 BTU ALL 009 208/230/60/1 061086002 Compr, 9100 BTU ALL 009 265/60/1 & 230/50/1 061086001 Compr, 11700 BTU ALL 012 115/60/1 060907804 Compr, 11700 BTU ALL 012 208/230/60/1 060907801 Compr, 11700 BTU ALL 012 265/60/1 & 230/50/1 060907802 Compr, 15500 BTU ALL 015 208/230/60/1 061043401 Compr, 15500 BTU ALL 015 265/60/1 & 230/50/1 061043402 Compr, 17700 BTU ALL 019 208/230/60/1 066540301 Compr, 17500 BTU ALL 019 265/60/1 & 230/50/1 066540302 BLOWER MOTOR Motor, 1/60 HP ALL 007, 009 115/60/1 073388001 Motor, 1/60 HP ALL 007, 009 208-230/60/1 073388002 Motor, 1/60 HP ALL 007, 009 265/60/1 073388003 Motor, 1/60 HP ALL 007, 009 230/50/1 106087101 Motor, 1/24 HP ALL 012 115/60/1 073384101 Motor, 1/24 HP ALL 012 208-230/60/1 073384102 Motor, 1/24 HP ALL 012 265/60/1 073384103 Motor, 1/8 HP ALL 012 230/50/1 106069801 Motor, 1/8 HP ALL 015, 019 208-230/60/1 067782202 Motor, 1/8 HP ALL 015, 019 265/60/1 067782203 Motor, 1/8 HP ALL 015, 019 230/50/1 067782201 FAN HOUSING & WHEEL Fan Wheel ALL 007-012 N/A 073383801 Fan Housing Assembly ALL 015, 019 N/A 061389101 REFRIGERATION CIRCUIT Reversing Valve ALL 007-009 N/A 106694116 Reversing Valve ALL 012 N/A 106694120 Reversing Valve ALL 015, 019 N/A 106694102 Solenoid-Reversing Valve ALL ALL N/A 910110435 Solenoid-Reversing Valve ALL ALL N/A 910110439 SENSOR Air Temp Sensor (DAT & RAT) ALL ALL N/A 107201601 Water Temp Sensor (LWT & EWT) ALL ALL N/A 107201601 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 1105024 Rev. Q 07/2016 CPL Page 1 of 2

Critical Daikin Applied OEM Parts Are What Your Daikin Applied HVAC Unit Needs! Console WSHP WWA*,WWB*,WWD*,WWL*, WWM*, WWX* Sizes 009-019 Design B (2) CRITICAL PART COMPONENTS MODEL UNIT SIZE VOLTAGE NUMBER CONTROLS Mark IV DC ALL ALL N/A 056792401 Mark IV AC ALL ALL N/A 056792402 MicroTech 2000 WWD*, WWX* ALL N/A 250808401 Alerton WWA* ALL N/A 106393501 COMPRESSOR Compr, 9200 BTU ALL 009 115/60/1 061086003 Compr, 9100 BTU ALL 009 208/230/60/1 061086002 Compr, 9100 BTU ALL 009 265/60/1 & 230/50/1 061086001 Compr, 11700 BTU ALL 012 115/60/1 060907804 Compr, 11700 BTU ALL 012 208/230/60/1 060907801 Compr, 11700 BTU ALL 012 265/60/1 & 230/50/1 060907802 Compr, 15500 BTU ALL 015 208/230/60/1 061043401 Compr, 15500 BTU ALL 015 265/60/1 & 230/50/1 061043402 Compr, 17700 BTU ALL 019 208/230/60/1 066540301 Compr, 17500 BTU ALL 019 265/60/1 & 230/50/1 066540302 BLOWER MOTOR Motor, 1/24 HP ALL 009 115/60/1 073384101 Motor, 1/24 HP ALL 009 208-230/60/1 073384102 Motor, 1/24 HP ALL 009 265/60/1 073384103 Motor, 1/60 HP ALL 009 230/50/1 106087101 Motor, 1/15 HP ALL 012 115/60/1 106433801 Motor, 1/15 HP ALL 012 208-230/60/1 106433802 Motor, 1/15 HP ALL 012 265/60/1 106433803 Motor, 1/40 HP ALL 012 230/50/1 106069801 Motor, 1/8 HP ALL 015, 019 208-230/60/1 067782202 Motor, 1/8 HP ALL 015, 019 265/60/1 067782203 Motor, 1/8 HP ALL 015, 019 230/50/1 067782201 FAN HOUSING & WHEEL Fan Wheel ALL 007-012 N/A 073383801 Fan Housing Assembly ALL 015, 019 N/A 061389101 REFRIGERATION CIRCUIT Reversing Valve ALL 009 N/A 106694116 Reversing Valve ALL 012 N/A 106694120 Reversing Valve ALL 015, 019 N/A 106694102 Solenoid-Reversing Valve ALL ALL N/A 910110435 SENSOR Air Temp Sensor (DAT & RAT) ALL ALL N/A 107201601 Water Temp Sensor (LWT & EWT) ALL ALL N/A 107201601 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 1105024 Rev. Q 07/2016 CPL Page 2 of 2