INNOVATIVE New Generation of Backwater Valves TECHNOLOGY. Fullport Backwater Valve NEW. Access Box Model # PE 2013

Similar documents
DWV PVC DWV Drain Waste Vent Fittings

A u t o matic Backw ater V alve

Series G. STI Gasketed Sewer Fittings SDR 35 STI. Injection Molded in Sizes 4 12 Fabricated in Sizes STI Gasketed Sewer SDR 35 G Series

Plugs & Test Equipment for Piping Systems

Plugs & Test Equipment for Piping Systems

Flexible Couplings & Saddles

P Series. Price List Effective February 11, 2008

1BGrease Traps and. Frequently Asked Questions About Grease:

The BEST Plumbing Specialties. One Source. L-21 TEST PLUgS

CATALOGUE Valves ~ Faucets ~ Specialties ~ Fittings & Nipples

elbow ball check valves Patents no.: US 8,146,618 B2, US 8,082,949 B2 in-line ball check valves Patent no.: US 8,146,618 B2 PRODUCT CATALOG

Compression Fittings & Valves. Make the connection

Overfill Prevention Valve

SaniTEE Wastewater Screens Installation & Service Manual FOR USE WITH SNT416, SNT418, SNT818, SNT 838, SNT1618, and SNT1638

PRE-PLUMBED SEWAGE SYSTEM

Jones Stephens Corp. PlumBest LTConnections SECTION E - COMMERCIAL & RESIDENTIAL PLASTICS. Closet Flanges & Accessories

THE GLOBAL LEADER IN PIPE PLUG & TESTING

ABOUT NORTH AMERICAN PIPE CORPORATION

An IDEX Water & Wastewater Business. pulsafeeder.com. Non-Metallic External Gear Pump

ABS DWV FITTINGS FOR PLUMBING AND MECHANICAL APPLICATIONS

BASE SHOE RAILING SYSTEMS

INFRASTRUCTURE DESIGN STANDARDS FIGURES SECTION 2 SANITARY SEWER COLLECTION SYSTEMS

No-Hub Couplings Drainage Drains Cleanout Plugs Cover Plates

Small Diameter N-12 Pipe and Fittings

GREASE INTERCEPTOR REQUIREMENTS

Flood Control Integrated System (FCIS)

Thompson Strainer MLS-2

CSO/STORMWATER MANAGEMENT. HYDROVEX FluidHook Control Gate Valve

MUELLER Super Centurion fire hydrants

Installation Instructions

ABS DWV FITTINGS JULY 1, 2011

Hampton Roads Planning District Commission

First Defense. Stormwater Treatment System. Operation and Maintenance Manual

Pipeline Testing. shorehire.com.au 1300 SHORE HIRE SYDNEY NEWCASTLE MELBOURNE BRISBANE

RAINWATER HARVESTING INSTALLATION GUIDE RH High Capacity Vortex Rainwater Fine Filter for Above or Below Grade Application

ABS DWV FITTINGS APRIL 1, 2013

Aqua Green Utility Inc.

GREASE INTERCEPTOR REQUIREMENTS Lakeway Municipal Utility District

APCO ASU COMBINATION AIR VALVE

MIDLAND PRECAST COMPANY, L.C. Tel: Hwy 14 PO Box 63 Toll Free: Corydon, Iowa Fax:

Heavy Wall Gasketed Sewer Fittings SDR 26 Injection Molded in Sizes 4 12 Fabricated in Sizes 15 36

INLINE 1100 STAGED PALLET SYSTEM. franklinwater.com

Table of Contents. Item Page #

INSTALLATION GUIDE. Model #GB2 35/50 GPM Grease Interceptor For Indoor Use. Contents

C h e c k M a t e I n l i n e C h e c k V a l v e

CAMEL YARD SEWER AND CATCH BASIN CLEANER NEW superproductsllc.com

Innovation... Refined! Lower profile, gentler conveyor design for easier, smoother self-filling and unloading

GB2 35/50 GPM Grease Interceptor for Indoor Use

City of Derby Water Pollution Control Authority Fats, Oils, and Grease Pretreatment Regulations Adopted March 15, 2017

Solvent Cements. LOOK INSIDE for the industry s most detailed cure charts. The choice of plumbing professionals.

PVC WELL CASING & FITTINGS 20 FT. BELL-END /8 SDR21 REDUCING COUPLINGS STEEL WELL CASING & FITTINGS

PRICE EACH PVC DWV FITTINGS SMALL AND LARGE DIAMETER MOLDED FITTINGS MARCH 1, 2017

MODELS 108 and 138 CRAWL SPACE PUMPING SYSTEM PREINSTALLATION CHECKLIST

ElJay. Legacy Series Screens

CSO/STORMWATER MANAGEMENT. Hydrovex VHV / SVHV Vertical Vortex Flow Regulator

Reliable backwater protection. Protection from backwater. Backwater protection for interior installation

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM

Solvent Cements. Look. The choice of plumbing professionals. for the industry s most detailed cure charts

JACUZZI AVALANCHE D.E. FILTER

INSTALLATION GUIDE. Model #GB1 20/25 GPM Grease Interceptor For Indoor Use. Contents

Lane Reverse Q Pond Outlet Installation and Maintenance Guide

HDPE FUSIBLE VALVES EXPECT INNOVATION

Stormwater Treatment System

This catalog contains the following geothermal accessory products and specification guides:

FORD TRANSIT VAN SOLUTIONS

The Universal Sewer Air Release Valve is designed to permit

Standards for Design and Construction

Valve Selection. 1. Function and service considerations

CENTRAL SLURRY SYSTEMS Model 915

CENTRAL SLURRY SYSTEMS Model 911

Saf-T Vent EZ Seal. Technical and Dimensional Data. Single Wall AL 29-4C Stainless Steel Special Gas Vent

US SERIES. Universal Sewer Valves. Universal Sewer Valves. Valve Function. Features Include

Page 1 of 19. Part# /10/2006

MAG- Backflow Preventers. MAG-BEECO Backflow Preventers deliver the highest level of performance, reliability, ease of use and save time and money.

User Manual BHI. Brookefield Hunter Incorporated 40 Buckskin Rd. Belgrade, MT 59714

Drain Waste & Vent (DWV) Systems SCJ PIPE & FITTINGS FOR NON-PRESSURE SEWERAGE APPLICATIONS

SEPTIC TANKS. Round septic tanks. Standard version ECO version. Rectangular septic tanks. ECO version

Please contact your supplier (supplying dealer or contractor) if service is necessary or if you have any questions or need further assistance.

VXE Series Ball Valves

BID TABULATION REPORT McKINNEY STREET DRAINAGE IMPROVEMENTS PROJECT No. PWDR10012 BID OPENED : TUESDAY, AUGUST 13, :00 P.M.

COMMERCIAL MULTIPORT VALVES

SUPERSEDES ABS-C0811/AUG.

E-Z Treat Installation Guidelines

Anti Siphon Ballcock RP Anti-Siphon Ballcock

HYDROCARBON SEPARATORS

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM. franklinwater.com

The new Staufix backwater valve. You can never improve the original. You can t. We can. Made in Germany.

Products for sewage systems

ABS DWV FITTINGS MARCH 1, 2017

BioSTEP Screened Pumping System Installation & Service Manual

SUBTOTAL SITE WORK & DEMOLITION (UTILITIES) $180, $348, $319,943.71

MODEL 7ASX-8 SPECIFICATION

Crispin Valves Operating Guide. Crispin

Excerpt from Chapter 3 of the City Code that address Fats, Oils and Grease (FOG) control program that was adopted by the City Council on May 9, 2016.

QWIK JON ULTIMA 204 SYSTEMS INSTALLATION INSTRUCTIONS PREINSTALLATION CHECKLIST

ADDENDUM #1 NWIT Watermain Replacement Program New Westminster, BC

Elite Skimmer Installation Manual. Manufacturers of Quality Pond Equipment & Supplies Item #PBESIM

OWNER S MANUAL GUZZLER MODEL 620 READ THESE INSTRUCTIONS BEFORE USING

No other jet/vac sewer cleaner can match this collection of no-extra-cost advantages VACALL.COM (800)

ABS-C0717 JULY 2017 SUPERSEDES ABS-C0217 CSA B181.1 ABS DWV FITTINGS.

Transcription:

WINNER 2005 NEW Access Box Model # PE 2013 Fullport Backwater Valve INNOVATIVE New Generation of Backwater Valves Clear transparent lid provides easy visual inspection Built-in sewer clean-out Model # 4963 A (ABS) #4963 P (PVC) www.backwatervalve.com / www.backwatervalve.ca Toll Free: 1-877-734-8691 TECHNOLOGY

Fullport Backwater Valve WINNER 2005 NEW Building Drain Protection Clear Top for easy visual inspection and cleaning Fullport (Normally-open) Non-Flow Restricting No problems with Blockages Gate closes automatically when sewer starts to backup Cleaning-rod does not destroy the gate when feeding or retrieving cable Normally-open design allows the free circulation of air throughout the plumbing system to the municipal sewer Award-winning technology Fullport normallyopen design offers no restriction to flow. Clear transparent lid provides easy visual inspection 11 Model #4963 A (ABS) #4963 P (PVC) Normal Flow 15 Reversal Flow Built-in main sewer clean out. INLET Floats Outlet 4 DWV Gate automatically rises upon reversal flow isolating entire plumbing system from backflow. INSTALLED JUST INSIDE FOUNDATION WALL Flow channels on gate and body divert sewage from inlet to outlet preventing sewage buildup. 16 typical Installation Poured Slab Earth 20 Access Box Model # PE 2013 10.5 www.backwatervalve.com / www.backwatervalve.ca Toll Free: 1-877-734-8691 Sewage Line Mainline Fullport Backwater Valve Sewage Line Note: 3/4 height difference between Inlet and Outlet Printed in Canada

Adapt-A-Valve Extendable Backwater Valve ADAPT A VALVE No Expensive Vault Required Ground Level Access at any depths Extendable Backwater Valve Cassette Gate ML-3XA (3" ABS) ML-3XP (3" PVC) (Extendable with Standard 4" DWV) ML-4XA (4" ABS) ML-4XP (4" PVC) (Extendable with Standard 6" DWV) Extendable Valve Body TEST-EZE-GATE Saves Testing Time Allows System to be Tested and Retested Building Cost Effective Exterior / INTERIOR Installation ADAPT A VALVE Pressure Test Your Plumbing System SAFELY QUICKLY EASILY with ADAPT -A- VALVE No More: Expensive and Dangerously Over-inflated Test Balls Hub Sets TEST-EZE-GATE Can be used over and over again www.backwatervalve.com Toll free # 1-877-734-8691 Printed in Canada

Adapt-A-Valve Extendable Backwater Valve Eliminates Manhole or Expensive Vaults Allows easy ground level access at any depths Removable seat and gate (Cassette) allows full servicing of unit Reflective sticker in body serves as guide for ease of cassette insertion Cassette locks in body Lightest gate in the industry offers next-to-no flow restriction Double-hinge gate design keeps gate aligned to seat O-ring seal For SDR Pipe use SDR adapters At Finished Grade, USE STANDARD DWV THREADED PLUG AND FIP or ALTERNATE CAP (Not Included) EXTENDABLE CASSETTE ALLOWS RETRIEVAL OF CASSETTE (3/4" Pipe not included) 3" Backwater valve EXTENDABLE with 4" DWV pipe* 4" Backwater valve EXTENDABLE with 6" DWV pipe* NORMALLY-CLOSED GATE CASSETTE Available Models: ML-3XA (3" ABS) / ML-3XP (3" PVC) ML-4XA (4" ABS) / ML-4XP (4" PVC) EXTENDABLE VALVE BODY *pipe not included OPTIONS TEST-EZE GATE FEATURE for ADAPT-A-VALVE Allows testing through your backwater valve Simply slide Test Gate into body and Pressure up Available for both 3" and 4" Adapt-a-Valve models Models: ML-3TZ (3") ML-4TZ (4") NORMALLY-OPEN GATE FEATURE Available by Special Order on 4" Model Only Installed with gate in horizontal position Special Gate, fitted with floats, floats gate to closed position on Reversal Flow Offers no flow restriction Air-flow not restricted O-ring seal DISTRIBUTED BY: LISTED COMPONENTS Cassette + Extension Adapter Backwater Gate Air gate component Extension Body Test Gate Printed in Canada

Setting A New Standard In Sewer Pressure Testing TEST-EZE-TEE INNOVATIVE TECHNOLOGY NEW Patent Pending 50 psi Air or Water Horizontal or Vertical Applications Safest / Quickest / Easiest and most Reliable Pressure Test You Will Ever Conduct! Simply Slide the Test-Gate in the Tee and you re Ready to Test! Eliminates Inflatable Test Balls, Mechanical Plugs and HubSett Call Toll Free: 1-877-734-8691 www.backwatervalve.com

TEST-EZE-TEE Order Information: TEST-TEE Body model # ML3TT ABS / ML3TT PVC TEST-GATE model # ML3TG SPACER-GATE model # ML3BLG Note: * all items sold separately * available in 3 at this time Typical Installation Procedures (Horizontal or Vertical applications) 1. Install tee in drainage line (prevent solvent cement from entering body) 2. Check and lubricate O-ring on Test-Gate 3. To prevent debris from entering guide slot, Install Test-Gate at same time of tee installation with O-ring facing pressure side 4. After Test, remove Test-Gate (reuse on next installation) If required, build a ¾ puller key (see below) 5. Body may be extendable with 4 DWV If Test-Gate not installed in tee at time of installation, order and install optional Spacer-Gate to keep debris from entering guide slot. Typical Installation Building a Removable Puller Key for your Test-Gate Advantage of building a removable key is that the key will not be left in ground where the gate may be prematurely removed by another contractor; provides savings in pipe when building multiple solid keys. Puller-Key Attach a ¾ tee onto a piece of ¾ pipe and attach a ¾ FIP on the end of the pipe. To remove Test- Gate on extended bodies, simply screw Puller Key onto ¾ gate thread and pull up. Threaded to easily attach Puller Key Optional Fill Feature: Test-Eze -Tee has two knockouts built into the body. By knocking out the knockout and solvent-welding a piece of ½ pipe and hose connection you may fill the system through the tee. For More Information contact 1-877-734-8691 www.backwatervalve.com

TEST-EZE TM PIPE-PLUG Center-tab Releases Pressure Center-tab Releases Pressure Pull-tab Safely Tears Plug From Cleanout Assembly TEST-EZE Plug simply inserts inside pipe prior to solvent welding pipe assembly Vertical Application TM PIPE-PLUG Extension Rip Cord Patent Pending Horizontal Application Pull-tab (cord) Safely Tears Plug From Cleanout Assembly Pull-tab Safely Tears Plug From Cleanout TECHNOLOGY INNOVATIVE NO MORE DANGEROUS INFLATABLE TEST BALLS EXPENSIVE MECHANICAL DEVICES TEST COUPLINGS Air or Water Air or Water SIMPLIFIES PRESSURE TESTING www.backwatervalve.com

Specifications Normally-closed Version PVC Body 4 Size PATENT PENDING 2 Hinge System O-RingO Seal Light Weight ABS Gate Applications Drainage Lift Stations Sewage Systems Septic Tanks Storm Water Retention Ponds End of Pipe Backflow Protection Various other applications Available in various sizes Normally-open Version also available Distributed by: www.backwatervalve.com Toll Free 1-877-734-8691