RaySafe X2. Specifications

Similar documents
RaySafe X2. Specifications

DÜRR NDT GmbH & CO. KG Höpfigheimer Straße Bietigheim-Bissingen

S1-568, S1-1068, S1-1568

ALS30. ALS31 Stud Mounting

ALS40. ALS41 Stud Mounting

CAN and Serial Instrumentation

Dragon 4 IR 12 PowerCluster

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

IMMOBILISER SYSTEM INTRODUCTION

Aluminum Electrolytic Capacitors, Power High Ripple Current, Screw Terminals

PHASED OUT. LED light engine / OLED LED linear / area. Module LLE G3 16x140mm 325lm ADV, LLE G3 16x280mm 650lm ADV Modules LLE ADVANCED

Intrinsically safe presure transmitters for hazardous environments Type MBS 4201, MBS 4251, MBS 4701 and MBS Technical brochure

DC-DC CONVERTERS 2:1 INPUT RANGE, UP TO 2 WATTS MEDICAL APPLICATIONS MTWA2 SERIES

USER MANUAL. White LED Light Meter. Model LT40. Additional User Manual Translations available at

DC-DC CONVERTERS 4:1 WIDE INPUT RANGE UP TO 9 WATTS SINGLE AND DUAL OUTPUT, SIP PACKAGE SWB9 SERIES

TSLC 6 UV LED 24v Strips

Best NDT Canada 413 March Road Ottawa, ON, K2K 0E4 Canada tel

Anti-Surge Thick Film Chip Resistors

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c

P500 Pressure Sensor. Description. Features. Applications MAIN FEATURES

Very high efficiency up to 93% Adjustable output voltage

Time scale: from 0.05 s to 100 h Multi-function Plug-in for use with 96 series sockets. Relay + socket. Wiring diagram (without control signal)

Pressure transmitters for heavy duty applications MBS 8200 and MBS 8250

Datasheet. Oslon10 Cluster White. LED Solutions. ILR-ON10-xxxx-SC201-xx series. Product Overview. Applications. Technical Features:

MBS 1200 and MBS 1250

Magnetic and Hydraulic-Magnetic Circuit Breaker

INTRODUCTION. The plug-in connection on the cables and lightning arrestors, allows for easy installation and replacement.

OEM Pressure Transmitters for heavy-duty applications Type MBS 1200 and MBS 1250

PDL09-48 S 05 M Series Name Input Output Output Case Voltage Quantity Voltage Option PART NUMBER STRUCTURE

Power Plugs for Proportional Valves (12 volt supply)

Pressure Transmitters

Anti-Surge Thick Film Chip Resistors

MUNTIFUNCTION SURVEY METER

Typical efficiency up to 93 % Up to 4 kw power (max. 16 kw) Liquid or convection cooling. CAN bus serial interface. Adjustable output voltage

LED light engine / OLED LED compact. Umodule STARK CLE CLASSIC EM STARK CLE

7E x0. Nominal current 5 A (32 A Maximum) 1-phase 230 V AC 17.5 mm wide

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Aluminum Capacitors Power High Ripple Current Screw Terminals

Emergency lighting units EM LED Light Engines. EM ready2apply BASIC 1 2 W EM ready2apply

OUTPUT VOLTAGE 5V MAX.INPUT CURRENT 16.0A 12V 7.0A 12V 12V 24V 35.0A 28V 48V 12V 15V 24V 28V 23.0A 48V 12V 15V 24V 28V 48V 11.5A

PHASED OUT. LED light engine / OLED LED compact. Umodule STARK DLE GEN2 CLASSIC STARK DLE

EBI 12 The new data logger generation

LED light engines ready2apply. Engine SLA AC G2 50mm SNC Engine SLA ESSENCE

C B. Operating up to 5000m altitude 5 year product warranty Models

Emergency lighting units EM converterled

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 150 WATT RAILWAY APPLICATIONS HWB150 SERIES

Pressure transmitter for industrial applications Type MBS 4510

Emergency lighting units EM converterled

Installation Instructions Electronic pressure sensor. PX3111 PX322x PX323x PX3244 PX3422 PX911x PX913x

LED light engine / OLED LED linear / area. Module LLE PREMIUM CRI90 LLE PREMIUM

LED light engine / OLED LED linear / area. Module STARK LLE PREMIUM Modules LLE

5 kv and 10 kv Insulation Resistance

first issue : last change : MSD Platinum 15 R number of pages : 12 LE 2166

PD-Series Ground Fault Circuit Protection

Pressure transmitter for general purpose Type MBS 1700 and MBS 1750

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Magnetic and Hydraulic-Magnetic Circuit Breaker

Lexium integrated drives

P-Series 11 to to to to to to to 1100 >1000 <25

High Current Thermal Fuse

PHASED OUT. LED light engine / OLED LED compact. Module CLE G2 190mm 1500lm ADV EM Modules CLE

LED light engine / OLED LED compact

LED light engines LED linear / area. Module STARK QLE G3 SELECT Modules QLE EXCITE

Aluminum Capacitors, Power High Ripple Current, Screw Terminals

OSLON 9 PowerCluster IR

Load (2) Single or Dual

MULTILAYER CHIP VARISTORS

Magnetic-Inductive Flow Meter FMI

HALF-BRICK DC-DC CONVERTERS 4:1 ULTRA WIDE INPUT RANGE 100 WATT RAILWAY APPLICATIONS HWB100 SERIES

EMC and Durability Lab, HCL Technologies Ltd., #73-74, South Phase, Ambattur Industrial Estate, Chennai

Pressure transmitters for industrial applications Type MBS 4510

Time scale: from 0.05s to 100h Multi-function Plug-in for use with 90.02, 90.03, and sockets

Efficient-Tec International LLC.

RAY COMPACT ENERGY METER MECHANICAL

1.4. Ex-Searchlight series SEB 8.., SEB 9.. and SEB 10. (Zone 1, 2, 21, 22) Search and working light

LED light engines LED linear / area

This annex is valid from: to Replaces annex dated: Location(s) where activities are performed under accreditation

USER MANUAL DDM30SC SINGLE PHASE DIN-RAIL KWH METER USER MANUAL TG ELECTRONICS. Manufactering company HUABANG OEM:101387

Emergency lighting units EM LED Light Engines

Lexium integrated drives

Thermal Circuit Breaker / Switch Series 3131

Aluminum Capacitors Standard - 85 C Snap-In

PHASED OUT. LED light engine / OLED LED compact. Module SLE G5 ART EXC Modules SLE EXCITE

Water, vibration and oil resistant LED work light, suitable for machine tools applications and high temperature water cleaning environments

Stanley 3J 1 PowerStar Whites

Reliability with the most essential intellect. Philips HF-Essential Electronic ballasts for TL5 lamps

Features. LED Driver. RACT09 9 Watt. TRIAC Dimmable. Single Output RACT09- AC/DC Converter

Magnetic and Hydraulic-Magnetic Circuit Breaker

LED light engine / OLED LED linear / area

PHASED OUT. LED light engine / OLED LED linear / area. Module QLE G1 488x239mm 2500lm ADV-SE Modules QLE

LED modules LED linear / area

Emergency lighting units EM converterled

Model Number Structure

Thermal Overcurrent Circuit Breaker 3120-F...

PDR circuit breaker - Ground fault Datasheet

Hand-held Fundus Camera (Model :HFC) Operating Manual

MINI-DC-UPS/24DC/2. Extract from the online catalog. Order No.:

Tunable White LED linear / area. Module LLE G2 PREMIUM LLE PREMIUM

Aluminum Electrolytic Capacitors Power Miniaturized Economy Long Life Snap-In

Magnetic-Inductive flow Meter fmi

Transcription:

RaySafe X2 Specifications

X2 GENERAL EMC According to IEC 61326-1 SAFETY According to IEC 61010-1 X-RAY METERS STANDARD Complies with IEC 61674 EXPOSURES NEEDED USB CABLES SIZE BASE UNIT BASE UNIT OPERATING TEMPERATURE STORAGE TEMPERATURE POWER SOURCE BATTERY One 2 m (6.6 ft), 5 m (16.4 ft) and 5 m active extender 34 x 85 x 154 mm (1.3 x 3.3 x 6.1 in) 521 g (18.4 oz) 15 35 C (59 95 F) -25 70 C (-13 158 F) Rechargeable Li ion battery ~ 10 hours intensive usage BATTERY TESTED According to UN 38.3 DISPLAY MEMORY SOFTWARE PTB CERTIFICATE 4.3 LCD with capacitive touch ~ 10000 latest exposures X2 View for data handling and analysis. Also exports data to Microsoft Excel. DE-17-M-PTB-0053 X2 mas mas 0.001 9999 mas 0.001 mas 1 % ma (PEAK) 0.1 1500 ma 0.01 ma 1 % 1 ms 999 s 0.1 ms 1 khz 0.5 % PULSES 1 9999 pulses 1 pulse PULSE RATE 0.1 200 pulses/s 0.1 pulse/s mas/pulse 0.001 9999 mas 0.001 mas 1 % WAVEFORM 125 µs* 1 khz * automatically reduced for exposures longer than 3 s UNFORS RAYSAFE DEFINITION The expanded uncertainty is stated as the combined uncertainty of measurement multiplied by the coverage factor k=2, which assuming a normal distribution has a coverage probability of 95 % (complies with GUM by ISO (1995, ISBN 92-67-10188-9)). Instrument specifications are subject to purchased configuration. All specifications may change without notice.

X2 R/F SENSOR SIZE ACTIVE COMPENSATION 42 g (1.5 oz) 14 x 22 x 79 mm (0.5 x 0.9 x 3.1 in) Beam quality independent for the following ranges: DOSE/DOSE RATE kvp TF DOSE DOSE RATE kvp HVL TRIG LEVEL 40 150 kvp, 1 14 mm Al HVL 40 150 kvp, up to 1 mm Cu 60 120 kvp, up to 1 mm Cu 1 ngy 9999 Gy (0.1 µr 9999 R) 5 % or 5 ngy (0.5 µr) 1 ngy/s 500 mgy/s (5 µr/min 3400 R/min) 1 ngy/s (5 µr/min) 50 ngy/s (340 µr/min) 5 % or 10 ngy/s (70 µr/min) x duty cycle 40 150 kvp 50 µgy (6 mr) RATE (PEAK) 10 µgy/s (70 mr/min) 2 % 1 14 mm Al 1 µgy (120 µr) RATE (PEAK) 0.5 µgy/s (3.5 mr/min) at > 70 kv 2.5 µgy/s (17 mr/min) at 50 kv 10 % TOTAL FILTRATION 1.5 35 mm Al 50 µgy (6 mr) RATE (PEAK) 10 µgy/s (70 mr/min) 10 % or 0.3 mm Al 1 ms 999 s 0.1 ms 0.5 % 4 Hz 4 khz* * automatically adjusted depending on signal level PULSES 1 9999 pulses RATE (PEAK) 0.5 µgy/s (3.5 mr/min) PULSE RATE 0.1 200 pulses/s RATE (PEAK) 0.5 µgy/s (3.5 mr/min ) DOSE/PULSE 1 ngy/pulse 999 Gy/pulse (0.1 µr/pulse 999 R/pulse) RATE (PEAK) 0.5 µgy/s (3.5 mr/min) WAVEFORMS kv DOSE RATE 62.5 µs* 0.1 0.4 khz** 4 Hz 4 khz** * automatically reduced for exposures longer than 1.5 s ** automatically adjusted depending on signal level

X2 MAM SENSOR SIZE ACTIVE COMPENSATION 42 g (1.5 oz) 14 x 22 x 79 mm (0.5 x 0.9 x 3.1 in) Beam quality independent for the following ranges: DOSE/DOSE RATE & HVL No selections needed. With or without paddle, with or without phantom. Mo/Mo, Mo/Rh Rh/Ag Mo/Al, W/Rh, W/Ag, W/Al, Rh/Rh, Rh/Al Mo/Cu, Rh/Cu, W/Cu, W/Ti 20 40 kvp 27 40 kvp 20 50 kvp 40 50 kvp kvp User selectable beam qualities. Paddle compensation available when relevant. DOSE W/Ag W/Al W/Rh Mo/Mo Mo/Rh Rh/Ag Mo/Cu, W/Cu, W/Ti 20 40 kvp 20 50 kvp Measuring above 40 kvp requires an X2 R/F Sensor + 2 mm Al (incl.) 20 40 kvp 20 40 kvp 32 40 kvp using + 2 mm Al (incl) 27 40 kvp 40 50 kvp, using the X2 R/F Sensor 1 µgy 9999 Gy (0.1 mr 9999 R) 5 % DOSE RATE 5 % 10 µgy/s 300 mgy/s (70 mr/min 2000 R/min) kvp HVL 20 50 kvp* Measuring above 40 kvp requires an X2 R/F Sensor and on W/Al +2 mm Al (incl.) 50 µgy (6 mr) RATE (PEAK) 10 µgy/s (70 mr/min) 2 % or 0.5 kv (without paddle) 2 % or 0.7 kv (with paddle) * depending on beam quality, see active compensation 0.2 3.6 mm Al 1 µgy (0.1 mr) 5 % above 25 kv 10% below 25 kv 1 ms 999 s 0.1 ms 400 Hz 0.5 % PULSES PULSE RATE DOSE/PULSE WAVEFORMS 1 9999 pulses 0.1 200 pulses/s 1 µgy/pulse 999 Gy/pulse (0.1 mr/pulse 999 R/pulse) 62.5 µs** 400 Hz ** automatically reduced for exposures longer than 1.5 s

X2 LIGHT SENSOR SIZE CLASSIFICATION STANDARDS LUMINANCE 136 g (4.8 oz) 48 x 60 x 68 mm (1.9 x 2.4 x 2.7 in) DIN 5032 part 7 class B Complies with relevant parts of AAPM TG18, IEC 62563-1 and IEC 61223-2-5. 0.01 10 000 cd/m 2 (0.03 34 000 fl) APERTURE ANGLE 5 MEASUREMENT AREA ILLUMINANT A DEVIATION FROM HUMAN EYE V(λ) (f 1 ) 0.001 cd/m 2 (0.001 fl) ø 10 mm (0.4 in) 3% < 3 % (see figure Photopic Response) ILLUMINANCE ILLUMINANT A DEVIATION FROM HUMAN EYE V(λ) (f 1 ) COSINE DEVIATION (f 2 ) 0.1 100 000 lux (0.01 9000 fc) 0.01 lux (0.001 fc) 3% < 3 % (see figure Photopic Response) < 3 % (see figure Cosine Response) Photopic Response Cosine Response 1.0 0.8 CIE 1931 V(λ) RaySafe X2 45 0 1.0 0.8 0.6 Cosine RaySafe X2 45 0.6 0.4 0.2 0.4 90 90 0.2 0.0 380 430 480 530 580 630 680 730 780 nm 135 180 135

X2 SURVEY SENSOR DIMENSIONS ACTIVE COMPENSATION TRIG MODES MANUAL AUTO H*(10) H*(10) RATE AIR KERMA 14 x 66 x 192 mm (0.5 x 2.6 x 7.6 in) 140 g (4.9 oz) H*(10) when selecting Sv Air kerma when selecting Gy or R Manual start and stop of measurement Trig level (N80): 10 µgy/h (1.2 mr/h) or 20 µsv/h 0 nsv 9999 Sv 1 nsv 10 %, N-series 20 150 kv 0 µsv/h 150 msv/h 10 % or 0.3 µsv/h, N-series 20 150 kv 0 ngy 9999 Gy (0 µr 9999 R) 1 ngy (0.1 µr) 5 %, RQA 50 150 kv 10 %, N-series 40 150 kv AIR KERMA RATE MEAN ENERGY 10 % RATE 0 µgy/h 100 mgy/h (0 mr/h 10 R/h) 5 % or 0.3 µgy/h (0.03 mr/h), RQA 50 150 kv 10% or 0.3 µgy/h (0.03 mr/h), N-series 40 150 kv 30 120 kev DEFINING STANDARD: ISO 4037-1 WAVEFORM RATE 10 µsv/h or 10 µgy/h (1 mr/h) 0.1 9999 s 0.01 s 1 Hz 10 ms 1 Hz 1 µsv/h or 1 µgy/h (0.1 mr/h) 10 Typical response MAM R/F & CT K air, [R&Gy] H*(10), [Sv] 1 0.1 10 125 I 241Am 100 99 Tc m 131I PET Nuclides 137 Cs 60 Co 1000 kev

X2 CT SENSOR SIZE SIZE Ø STANDARD ACTIVE LENGTH ENERGY DEPENDENCE AUTOMATIC ENVIRON- MENTAL COMPENSATION DOSE 86 g (3.0 oz) 14 x 22 x 219 mm (0.5 x 0.9 x 8.6 in) 12.0 mm (0.47 in) For measurements in accordance with IEC 60601-2-44 100 mm (3.94 in) < 5 % for 70 150 kv (RQR, RQA and RQT beam qualities) 55 110 kpa, 15 35 C (59 95 F) 10 µgy 999 Gy (1 mr 999 R) 5 % DOSE LENGTH PRODUCT 5 % DOSE RATE 5 % 100 µgycm 9999 Gycm (10 mrcm 9999 Rcm) 10 μgy/s 250 mgy/s (70 mr/min 1700 R/min) 10 ms 999 s 1 ms 10 Hz 0.5 % WAVEFORMS 1 ms 10 Hz

Unfors RaySafe offers comprehensive solutions for the X-ray room to measure the performance of X-ray equipment and to monitor medical staff dose in real-time. RaySafe helps you avoid unnecessary radiation. 2017.11 Unfors RaySafe 5200078-10.1 www.raysafe.com