Domae. The right solution for distribution boards

Similar documents
PDL s DBF AND DBS SERIES DISTRIBUTION BOARDS

TX³ RCCBs 2P up to 100 A

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

DSE201 Compact design with enhanced protection

DX³ RCCBs - ID 4P up to 100 A

QUALITY ASSURANCE & DOCUMENTATION

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

DX³ 4-pole RCBO 6000 A/10 ka

R.C.B.O. SP / 1 module

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

New DX 3 High rating & breaking capacity

Phase + Neutral, neutral on right side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

COMPLETE SOLUTIONS FOR POWER PROTECTION

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

Effective discrimination of protective devices

DX³ RCBO 6000 A Phase + Neutral, neutral right side

XL 3 -N SimPly, EfficiEnt And SAfE. 3 - PHASE distribution boards up to 250 A

Chapter P Residential and other special locations

Phase + Neutral, neutral on left side

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

DPX moulded case circuit breakers

Offers. QOvs RCBO residual current devices. Protection Earth leakage protection. Variants

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

SF 6 Gas Insulated Switchgear Type SDH314 / SDHa314 for 72.5 to 145 kv

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

RESIDUAL CURRENT CIRCUIT BREAKER

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Electrical distribution and safety for homes Catalogue SquareD Consumer units and protection devices

Btdin RCBO 6000A up to 63A (2P)

dx 3 protection that meets your requirements GloBal SpecialiSt IN electrical AND DIgITAl BUIlDINg INFrASTrUCTUreS catalogue pages inside

RX 3 M.C.B A up to 63 A

Technical Journal September 2012

Unit price (incl.vat) in VND Domae MCB - 1P/1P+N, 4.5kA & 6kA, 230/240V Domae MCB 1P. 4.5kA Reference 112, DOM , DOM11341

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Residential and light commercial. invicta. panelboards

DX³ RCBO 6000A Phase + Neutral, neutral on left

and other modular devices for low voltage installation

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

DOMINO Series surface mounting IP55

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

(1,5 modules per pole)

RX 3 M.C.B A up to 63 A

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

MCBs and RCDs LR TM 6000

Greater protection UNDERSTANDING THE 17TH EDITION CONSUMER UNITS / PRODUCT GUIDE

Low Voltage A GE Power Controls Company. General catalogue

EAD10H80D EAD14H80D EAD17H80D

B kv T&D GAS INSULATED SWITCHGEAR

NXPLUS C Single busbar. Maintenance-free for lifetime

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Consumer Switchboards and Circuit Protection Flexible range designed for domestic and commercial installations


WORKSHOP SPECIFICATIONS

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

XL Distribution enclosures WORKSHOP SPECIFICATIONS

Vistop TM isolating switches 63 to 160A

TECHNICAL SPECIFICATION

MEDIUM VOLTAGE PRODUCTS. Powerbloc Pre-assembled modules for building medium voltage switchgear

BETA Switching Switches and Light Indicators

Modular contactor for installation into distribution boards

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

Cat N 3. OVERALL DIMENSIONS

Surge-Trap Pluggable STPT2 Series - 40kA

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

LV Capacitor CLMD03 Power Module Instruction manual

Selection Guide Motor Control Device Solutions

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

DX³ RCBO 6000A Phase + Neutral, neutral on right

XL³ 400 metal distribution cabinets, free-standing enclosures and cable compartments

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)

BETA Low-Voltage Circuit Protection

EVOline. Express. International socket versions available. Various colours available. Cascadable.Extendable. International.

MoDPlus Din Distribution Boards

CPG.0 Single busbar gas-insulated cubicles

GROUP TP&N DISTRIBUTION BOARD TYPE B. Distribution boards for modern commercial & industrial installations

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

The young energy ensures more safety

up to 63 A (1 module per pole)

Wall mounted switchgear

ELECTRICIANS REGULATIONS EXAMINATION 25 June 2011

MODVAR Low voltage reactive power compensation modules Installation manual

Unified requirements for systems with voltages above 1 kv up to 15 kv

Miniature Circuit-Breakers (MCBs)

Viking 3 - Screw connection Disconnect terminal blocks

ABB STOTZ-KONTAKT GmbH

Transcription:

Domae The right solution for distribution boards

Guaranteed quality and adapted solutions Domae : SIRIM approved The quality marks prove product conformity to their reference standard. They guarantee: safety of installers, suitability of products for their use. With the Merlin Gerin Domae offer, Schneider Electric guarantees the very best in quality for this entire product range (26 ISO 9001/2000 certified production and development sites world-wide). Whatʼs more, because this range has been built to comply with European and international standards as well as local authority, Suruhanjaya Tenaga and SIRIM requirements you know you will be working in complete safety. For electrocution protection: Domae residual current circuit-breakers For short-circuit and overload protection: Domae circuit-breakers For easy installation: Domae enclosures For quick connection: Domae comb busbars For lightning protection: Surge arrester For remote control: Impulse relay and contactor For time control: Time relays IH, IHP SIRIM Labels With increase in trade and a corresponding increase in demand for quality and safety by government authorities, purchasers and consumer, there is a need for a means of providing assurance that the product complies with IEC 60898. SIRIM labels are security labels, serially numbered and is only affixed on the certified regulated products. These labels have to be purchased from SIRIM QAS International and licences are required to record the use of these labels. SIRIM labels on Domae provide complete guarantee of operation, compatibility and safety according to national and international standards.

Domae A comprehensive range Domae products can be easily identified by their new design Connection terminals: terminals with guard for rigid copper cables Neutral pole position indicator: N Diagram Brand: Merlin Gerin Technical information 2-position handle: ON/OFF with 0/I indicator Clamping screw: Screw head: 5 mm blade or PZ2 recessed Sales catalogue number Domae circuit-breaker Domae residual current circuit-breaker Terminal capacity 25mm 2 max Tripping curve Current Rating Breaking capacity (max short-circuit current: 4500 or 6000 A) Terminal capacity 35 mm 2 max Test button (monthly test recommended) Current Rating Limitation class: 3 Sensitivity Voltage rating Voltage rating A remarkable profile Large terminals, screws for flat-headed or recessed head screw screwdrivers Domae comb busbar Nominal current: 63 A (cross-section 10 mm 2 ) Brand: Merlin Gerin End pieces Connector

... adapted solutions The Domae enclosures c Colour: white RAL 9003 c Material: insulating self-extinguishing material fl ame resistance 650 /30 s c Degree of protection against solids: IP40 (protected against solids dia. > 1mm) c Degree of protection against impacts: IK 07 (protected against impacts < 2 joules / 0.5 kg) c Class of protection against indirect contacts: class 2 c Capacity: 12, 18, 24 or 36 Domae surface-mounted enclosure Back: Easy to position: - centred oblong opening (equipped with a class 2 enclosure insulating plug) - vertical position adjustment oblong holes (equipped with a class 2 enclosure insulating plug) Convenient to install: Cable insertion by drilling pre-punched out zones Cover: Design: - curved door - blanking plate Professional: - circuit identifi cation by self-adhesive strip (enclosure delivered with one strip per row), Quick to connect: terminal blocks Comb busbar 40 A 30 ma C10 C16

Domae Electrical hazards Choice of protection devices Short-circuit and overload protection Cables Protection Power socket circuit : 2.5 mm 2 1 C16 1 protection device for 8 sockets maximum circuit-breaker Lighting circuit : 1.5 mm 2 1 C10 1 protection device for 10 lighting points maximum circuit-breaker Specifi c circuit : 4 mm 2 1 C32 1 protection device by application circuit-breaker Electrocution protection 1 protection device 1 30 ma for the power socket circuit residual current and specifi c circuit assembly circuit-breaker Fire protection 1 300 ma or 100mA 1 general protection device residual current circuit-breaker Lightning protection 1 general protection device 1 surge arrester Everyday comfort Multiple control for lighting circuit Commande 1 relay by multiple 1 TL control circuit impulse relay Power control 1 relay by specifi c 1 CT circuit contactor Simple management of circuit opening and closing 1 timer by 1 timer specifi c circuit

For more protection, safety and control Residual current circuit breaker The earth-leakage protection device is the most reliable apparatus for isolating circuits in which damage in the insulation is occured and electrical current is circulating through the earth. It equally protects people from electrocution while being accidently exposed to direct and indirect contact with live conductors. It functions on electro-mechanical principle by comparing the current <entering> through the phase conductors with this <going out> through the neutral conductor. If certain difference between these two currents is registered, meaning that the insulation level has dropped down and dangerous earth current starts to flow, the earth-leakage device trips. The Residual Current Circuit Breaker (RCCB) is a solution to ensure all installations against earth leakage damages. The Domae RCCB range guarantee the circuit isolation when ìopenedî and the best earth leakage protection for al type of circuits. It fits the international standard requirements IEC61008 & IEC60364. This range is dedicated for people and fire protection. The RCCB can be used in all earth systems: TT, TNS, TNC-S. Impulse relays TL Build an installation that allows you a comfortable control of lighting from various points. The impulse relays TL allow remote control of the circuits by means of impulse commands from several points. They are used for control of active loads (incandescent lamps, halogen lamps for ultra low voltage) and inductive loads (fluorescent lamps, gas discharge lamps) Contactors CT For switching of powerful loads such as electric boilers, pumps etc. Merlin Gerin offer modular contactors for control of single and three phase feeders with current up to 100 A. Time relays IH, IHP For switching of some circuits in your absence Merlin Gerin offers mechanical IH and electronic IHP time relays. By using them you may realize different programs repeating from every 60 minutes to yearly programs with many convenient options. Surge Arresters Domae Quick PF Overvoltages by lightning are extremely dangerous and may destroy sensitive devices such as TV sets, computers and other household appliances. Surge arresters provide effective protection against such phenomena. The most important aspect in lightning protection is to select the appropriate surge arrester and disconnector. Merlin Gerin offers an innovative concept: Quick to choose, Quick to install and Very efficient. Thus offering only two references covering most residential needs. An extended offer will also be available upon request.

Domae References & Curve 1 = Thermal tripping limit 2 = Electromagnetic tripping limit Curve C the magnetic trip units operate between 5 in and 10 in. Curve B the magnetic trip units operate between 3 in and 5 in. Available from June 2006 Surge Arrester Type Poles Rating Un (V) Cat. No Domae Quick PF 1P+N 10kA 230 DOML102F230 Domae Quick PF 3P+N 10kA 230/400 DOML104F400 TL Impulse Relay Type Description Rating Un Cat. No TL On-off switch, 1P 16A 230V AC DOMT1F16 CT Contactor Poles Type Rating Un Cat. No 2P 2NO 20A 230V AC DOMK2F20 Enclosures Nbr Installation Nbr of rows module Cat. No Surface Mounted 1 12 13369 Surface Mounted 1 18 13370 Surface Mounted 2 24 13922 Surface Mounted 3 36 13923 1m Long Comb Busbars Type Rating (A) Description Cat. No 1 Ph 63 1m bar 1 x 10mm 2 10388 2 Ph 63 1m bar 2 x 10mm 2 10390 3 Ph 63 1m bar 3 x 10mm 2 10392 Accessories Cat. No 1 set of four 35mm 2 connectors 10397 1 set of 10 bar end pieces (2 phase) 10398 1 set of 10 bar end pieces (3 phase) 10399 1 set of 10 tooth shields 10396 Time Relay Interval Between 2 switching Type width (mm) Spring Reserve operation Rating (A) Un Cat. No IH, 1c, 24h 54 150h 30 min 16 230V AC 15365 IH, 2c, 24h 54 150h 30 min 16 230V AC 15337 IHP 1c 45 5 years 1 sec 16 230V AC 15851 IHP 2c 45 5 years 1 min 16 230V AC 15853

References Domae Circuit Breakers Circuit Breaker (MCB) C Curve 4.5kA Nbr of pole Width (mm) Rating (A) Cat. No 1P 18 6 DOM11340 1P 18 10 DOM11341 1P 18 16 DOM11342 1P 18 20 DOM11343 1P 18 25 DOM11344 1P 18 32 DOM11345 1P 18 40 DOM11446 1P 18 50 DOM11335 1P 18 63 DOM11336 2P 36 6 DOM11230 2P 36 10 DOM11231 2P 36 16 DOM11232 2P 36 20 DOM11233 2P 36 25 DOM11234 2P 36 32 DOM11235 2P 36 40 DOM11236 2P 36 50 DOM11237 2P 36 63 DOM11238 3P 54 6 DOM11347 3P 54 10 DOM11348 3P 54 16 DOM11349 3P 54 20 DOM11350 3P 54 25 DOM11351 3P 54 32 DOM11352 3P 54 40 DOM11353 3P 54 50 DOM11337 3P 54 63 DOM11338 B Curve C Curve Circuit Breaker (MCB) 6kA 6kA Nbr of pole Width (mm) Rating (A) Cat. No Cat. No 1P 18 6 DOM11362 DOM11375 1P 18 10 DOM11363 DOM11376 1P 18 16 DOM11364 DOM11377 1P 18 20 DOM11365 DOM11378 1P 18 25 DOM11366 DOM11379 1P 18 32 DOM11367 DOM11380 1P 18 40 DOM11414 DOM11381 2P 36 6 DOM11417 DOM11384 2P 36 10 DOM11418 DOM11385 2P 36 16 DOM11419 DOM11386 2P 36 20 DOM11420 DOM11387 2P 36 25 DOM11421 DOM11388 2P 36 32 DOM11368 DOM11389 2P 36 40 DOM11369 DOM11390 3P 54 6 DOM11426 DOM11393 3P 54 10 DOM11427 DOM11394 3P 54 16 DOM11428 DOM11395 3P 54 20 DOM11429 DOM11396 3P 54 25 DOM11430 DOM11397 3P 54 32 DOM11430 DOM11398 3P 54 40 DOM11432 DOM11399 Domae Residual Current Circuit Breakers Residual Current Circuit Breaker Nbr of pole Width (mm) Rating (A) Sensitivity (ma) Cat. No 2P 36 40 30 DOM16793 2P 36 40 100 DOM16818 2P 36 40 300 DOM16795 2P 36 63 30 DOM16791 2P 36 63 100 DOM16819 2P 36 63 300 DOM16798 4P 72 40 30 DOM11029 4P 72 40 100 DOM16814 4P 72 40 300 DOM11030 4P 72 63 30 DOM16794 4P 72 63 100 DOM16815 4P 72 63 300 DOM16796

Domae Dimensions Surface-mounted enclosures 19 cm 20 cm 14.5 cm 20 cm 16.5 cm 22 cm 25.5 cm 9.5 cm 13.5 cm 13.5 cm 36 cm 10 cm 12 ways 18 ways 27 cm 32.5 cm 8 cm 8 cm 25.5 cm 34 cm 34 cm 10 cm 10 cm 39.5 cm 45 cm 8 cm 8 cm 25.5 cm 24 ways 36 ways MCB 3 POLE RCCB 4 POLE 3P 2P 1P