ATM 322 PNEUMATICS MODULE 4

Similar documents
Basic Pneumatics. Module 6: Flow control Valves. Academic Services PREPARED BY. April 2012

Basic Pneumatics. Module 4. One way flow control valve & Quick exhaust valve PREPARED BY. IAT Curriculum Unit. January 2011

Actuators and directional control valves

Basic Hydraulics. Module 2: Actuators and directional control valves. Curriculum Development Unit PREPARED BY. August 2013

Basic Hydraulics and Pneumatics

The pneumatic circuit and parts' list needed to perform this operation are shown by Figure C.1.

Introduction. Pre-Lab

Basic Pneumatics. Module 1: Introduction to Pneumatics. Academic Services PREPARED BY. August 2011

: Automation Laboratory 1

Circuit simulation software

Pneumatic Systems. Module 3: Logic Operations in Electropneumatics. IAT Curriculum Unit PREPARED BY. August 2008

I) Clamping the work piece II) Drilling the work piece. III) Unclamping the work piece. 10

Hydraulics Simulation Software (LVSIM -HYD) - 10 Users Network (6385-Q0)

PNEUMATIC & HYDRAULIC SYSTEMS

CH.4 Basic Components of Hydraulic and Pneumatic System/16 M HAP/17522/AE5G

FRL unit consist of Filterations, Regulators and Lubricator unit.

Electropneumatics Basic Level Set of Overhead Transparencies TP 201

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL HYDRAULIC AND PNEUMATIC CYLINDERS. This work covers part of outcome 2 of the Edexcel standard module:

Experiments on Hydraulic and Pneumatic circuit trainers HYDRAULIC CIRCUITS:

Chapter 6 Pneumatic Logic Sensors and Actuators

Test. What type of cylinder would you use? A. Single-acting cylinder B. Double-acting cylinder Answer:

FLUID POWER FLUID POWER EQUIPMENT TUTORIAL PNEUMATIC CIRCUTS. This work covers part of outcome 3 of the Edexcel standard module:

SUMMARY KIT PNEUMATIC MOTION

RELEASING PRESSURE IN THE HYDRAULIC SYSTEM,

Angle Seat Control Valve 7020

University of Jordan School of Engineering Mechatronics Engineering Department. Fluid Power Engineering Lab

Industrial Mechanic (Millwright) Level 3

Intake and Exhaust System, Design and Function

Product design: Mechanical systems. Pneumatics. Putting tops on milk bottles. Opening and closing bus doors

Input, Control and Processing elements

LESSON 2 BASIC CONSTRUCTION AND OPERATION OF HYDRAULIC ACTUATING DEVICES, FLOW CONTROL, AND DIRECTIONAL DEVICES. STP Tasks:

This information covers the design and function of the intake and exhaust systems for the Volvo D16F engine.

Modern Industrial Pneumatics. Design and Troubleshooting Industrial Pneumatics PN111 PN121

2. Hydraulic Valves, Actuators and Accessories. 24 Marks

Industrial Pneumatic Systems Syllabus [Detailed]

The filling pressure of SUSPA gas springs depends on the extension force and the geometry and is between 10 and 230 bar.

Push buttons are of two types i) Momentary push button ii) Maintained contact or detent push button

Tube connection Ambient temperature range Medium temperature range. T min C +80. C T max. max. Weight (mass) kg See table

Project 05: Simulating loads at the hydraulic cylinder using a throttle check valve

Z1 B1 B2 Z2 B3 B4. Steuerteil + 24 V. Leistungsteil K1 K2 K1 K2. Practice for Professionals Electropneumatics Trainee s manual. Version 1.

JIS symbols used in this catalog are old symbols following JISB0125-1: Refer to JISB0125-1: 2007 or JFPS2011: 2006 for new symbols.

CYLINDERS AND VALVES SERIES KNORR. Moving more than air

Lesson 5: Directional Control Valves

PNEUMATIC BOOSTER HIROTAKA MFG. CO.,LTD.

ScienceDirect. Modelling, Simulation and Control of a Foldable Stair Mechanism with a Linear Actuation Technique

Special valves. Logic components AND/OR Timer 2/2 way screw-in valves Miniature screw-in pressure regulators Relief valves

Check Valve Series AK How to Order

Subject: Pneumatic Training Kit with portable Air Compressor

/2017. Swing sink clamping element double-acting

Chapter 11: Valves and Actuators with the NAMUR-interface

SWING GATE OPENER SW300 SERIES

ATA Series (Patented)

standards based cylinder DNCI Operating instructions e [ ]

Agilent Aluminum Block Valves - Series 26 NW 16 - NW 40 ISO-KF Flange

Projekthandbuch. Project Manual Industriehydraulik. Industrial Hydraulics RE 00846/ Trainee's manual. Schülerhandbuch

HYDROMODEL-200. Implements and controls hydraulic and electro-hydraulic circuits. Transparent Hydraulics - Electro-hydraulics

XT912 Microlight Trike Hand Control Equipment

Front panel valves SV

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

Standards ISO Max. particle size 50 µm. Pressure for determining piston forces 6 bar. Materials:

Project Manual Industrial Hydraulics

OPERATING INSTRUCTIONS & SERVICE MANUAL BLUE MAX II HYDROSTATIC TEST PUMP

Electro Pneumatic WorkStation Scientech 2470

Task 4: Read the texts, look at the illustrations and do the activities below.

Fluidics. Hydraulic circuit. Course teacher Prof. Mahbubur Razzaque

AGILENT VACUUM VALVEs

Hydraulic Master Cylinders

Air Valve AIR-PILOTED VALVES

Section 1: Pneumatic Systems

Hydraulics and Pneumatics Simulation Software (LVSIM -HYD & PNEU) - 1 User

INTEGRATED HYDRAULIC BRAKE

BASIC PNEUMATICS BASIC PNEUMATIC CIRCUITS LEARNING ACTIVITY PACKET BB834-BA02XEN

INDIAN INSTITUTE OF TECHNOLOGY KHARAGPUR NPTEL ONLINE CERTIFICATION COURSE. On Industrial Automation and Control

Type TW02. WEH - We Engineer Hightech. WEH Connector for pressure and vacuum testing DATA SHEET

CH.6 Hydraulic and Pneumatic Circuits/20M. 6.1 Hydraulic Circuits

Motorcycle Carburetor Theory 101

Releasable check valve type RH

Pneumatic Trainer Kit

INSTRUCTION MANUAL INSTALLING NEW GREASE IN UT SERIES PNEUMATIC ACTUATOR

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

2/ VDMA (ISO ) 5/2-5/3-way CC CO CP. CATALOGUE > Release 8.8 CONTROL > Series 7 valves and solenoid valves GENERAL DATA

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Cylinders with integrated guide Series QCTF and QCBF

Solenoid valve. Solenoid Coil

PNEUMATIC CYLINDERS. Pneumatic Cylinders. Pneumatic Cylinders. Pneumatic Cylinders sometimes known as air cylinders are mechanical devices

EXPERIMENTAL MODELS OF ONE WAY VALVES MADE USING RAPID PROTOTYPING

CURRICULUM BOSCH-REXROTH (CENTRE OF EXCELLENCE) GANPAT UNIVERSITY

Pneumatic. PVD Ceramic Valves

Main Steam Isolation Valves (MSIV) in Nuclear Power Plants with PWR

SPOOL VALVES. pilot operated single/dual solenoid (mono/bistable function) ISO mm - pad mounting body M12 connection

PED Pneumatic Escapement Modules Double Escapement Sizes Weight Advancing force Stroke Bending moment

2/2-way, 3/2-way NC and NO. Monostable - bistable (with magnetic memory) Ports M5 and G1/8 - cartridge ø4

The Discussion of this exercise covers the following points:

ZEUS type BRONZE PNEUMATIC ACTUATED VALVE. Model/Ref:

Short-stroke cylinder, Series SSI Ports: M5 - G 3/8 double-acting with magnetic piston Cushioning: elastic Piston rod: Internal thread

XL HYDROSTATIC TRANSAXLES

Electro - Hydraulics. & Pneumatics. Electro Hydraulic Press. Comparison. Electro Hydraulics. By: Alireza Safikhani

Accessories for smart valve automation. 3. page 29

HV gate valve Series 11

Maintenance Information

Transcription:

ATM 322 PNEUMATICS MODULE 4

WARM UP VIDEO

Explain the function of the one way flow control valve. Describe the main parts of the one way flow control valve. Adjust the one way flow control valve to the required actuator speed. Explain the function of a quick exhaust valve. Identify the main types of flow control used with double acting cylinder Draw the required circuit diagram that controls the speed of the forward stroke of a double acting cylinder. Simulate the pneumatic circuit that controls the speed of the forward stroke of the double acting cylinder using FluidSIM software. Explain the difference between the one way flow control valve and the quick exhaust valve.

Controls the flow rate in one direction only & allows free flow in the opposite direction. I.S.O Symbol

The One way Flow Control valve consists of: + = Check valve + Throttle valve = One- way FCV

If the flow is from (P) to (A), the check valve stops the flow passing in this direction and the flow then passes through the throttle valve. The cross-section of the throttle is adjustable via a regulator screw. If the flow is in the opposite direction from (A) to (P), the check valve permits the flow freely from (1) to (2)

Supply Air Throttling Exhaust Air Throttling

SUPPLY AIR THROTTLING Control the speed of the cylinder in the advance stroke In the case of supply air throttling, the one-way flow control valves are installed such that air being fed to the cylinder is restricted. Exhaust air can escape freely via the 5/2 way valve. Supply air throttling is used for single acting cylinders and small volume double acting cylinders.

EXHAUST AIR FLOW CONTROL Control the speed of the cylinder in the advance stroke In the case of exhaust air throttling, supply air flows freely to the cylinder and the flow control in the exhaust line resists the escaping air. The piston is held between two air cushions. Exhaust air throttling should always be used for large double acting cylinders with long strokes, and when the loads are not constant.

The following items are required to complete this task: 1) Single acting cylinder 2) 3/2 way valve N/C 3) One way flow control valve 4) Pressure supply

PROCEDURES: 1-Prepare the components according to the components list. 2- Mount all components according to the Pneumatic circuit. 3- Connect pneumatic tubes according to the pneumatic circuit. 4- Check all parts are connected properly with each other. 5- Switch on the service unit. 6- Start the circuit and check the operation. 7- Turn off the service unit. 8- Dismantle and tidy up.

In many applications especially with single acting cylinders, it is a common practice to increase the piston speed during retraction of the cylinder to save the cycle time. This is carried out by incorporating a Quick exhaust valve.

The Output port 2 is directly fitted on to the working port of cylinder. Supply port 1, is connected to the output of the final control element (Directional control valve). The exhaust port 3 is left open to the atmosphere

Compressed air flows from the directional control valve to the cylinder via the quick exhaust valve from port (1) to port (2). Exhaust port 3 is closed at this time. When pressure at port 1 drops, exhaust flow occurs from port (2) to port (3). In order to implement optimized quick exhaust, the valve must be connected directly to the cylinder s supply port.

Required items for completing this task are: 1) Single acting cylinder. 2) 3/2 way valve N\C 3) Quick exhaust valve

Procedures: 1- Prepare the components according to the equipments list. 2- Mount all components according to Pneumatic circuit. 3- Connect pneumatic tubes according to the pneumatic circuit. 4- Check all parts are connected properly with each other. 5- Switch on the service unit. 6- Start the circuit. 7- Turn off the service unit 8- Dismantle and tidy up.

Task Description: A gate valve operated by double acting cylinder is used in controlling a filling system for plastic pellets. The gate valve needs to be closed quickly during the forward stroke of the double acting cylinder. However, it should be opened slowly during the backward stroke of the double acting cylinder. A double pilot (memory) valve should be used to operate the double acting cylinder.

Task Requirements: 1. Draw pneumatic circuit diagram 2. Simulate the circuit using FluidSIM software. 3. Assemble the circuit practically and check its operation.

1)www.Fest-didactic.com 2)http://www.eng2all.com/vb/t28 932.html 3)http://www.logiclab.hu/lesson.ph p?fe=2