PEDIATRIC SCALE. Models 459-CH, 8432-CH and 8432-CHKGEU Owner s Manual

Similar documents
DIGITAL Pediatric Scale Models 8435 & 8435KG Owner s Manual

MARINER MODEL WPS12 WATERPROOF DIGITAL PORTION SCALE OWNER S MANUAL

Cardinal DETECTO. PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

DIGITAL PHYSICIAN Waist-High Scale. Eye-Level Scale. Model 6127 Series, 6129 Series and. Models 6337 and 6339 Operating Instructions

ELECTRONIC PHYSICIAN Waist-High Scale 6027 and 6029 Series Owner s Manual

Price Computing Scale D Series Operation Manual

DIGITAL PHYSICIAN Waist-High Scale Models 8430, 8431 & 8437 Operating Instructions

MODEL PS-4 DIGITAL PORTION SCALE

PORTABLE PLATFORM SCALES Digital Type Series 850F Owner s Manual

Digital Stand-On Sit-Down Scale Models 6876 & 6876KGEU Operating Instructions

Digital Stand-On Sit-Down Scale Models 6868 & 6868KGEU Operating Instructions

7550 Fold-up Stationary Wheelchair Scale Installation and Operation Manual

DIGITAL PHYSICIAN Eye-Level Scale

Patient Lift Scale Indicator Owner s Manual

SONARIS Sonar Stadiometer Owner s Manual

Price Computing Scale DS Series Operation Manual

WARNING. Introduction ! ATTENTION

Digital Stand-On Sit-Down Scale Models 6868/6868KGEU Operating Instructions

DIGITAL PHYSICIAN Waist-High Scale

Waist-High Digital Bariatric Scale Model 685X Series Operating Instructions

PD100 PD200 PD300 PD300DHR

PD100 PD200 PD300 PD300DHR

IB-400. Weighmobile. Owner's Manual

SPC Series. Digital Scale. Operation Manual

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Compact Scales. Software Revision V1.25 & above

Digital Clock model 75100C

Thermometer models / 00831A

Model DS7060 Handrail Scale. User Manual

Wireless Thermometer model 00380

PVI 60KW, PVI 82KW, PVI 95KW

BroadBand PowerShield. 20 AHr Battery. User Manual

IB-600. Weighmobile. Owner's Manual

Owner's Manual. For latest instructions please go to

Owner's Manual. For latest instructions please go to

8-Bay Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual. Please read before using this equipment.

BATTERY CHARGER INSTRUCTION MANUAL. model no. ACG112CL

37SCENE 46SCENE 79SCENE

82V LITHIUM-ION BATTERY CHARGER GC 400

Penguin Gentoo 600B Cordless Sprayer User s Manual

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

10 Year Limited Warranty

Thermometer model 00826

AXD 530 MicroManometer

Owner's Manual. For latest instructions please go to

Thermometer models 02023/02028/02053/02054

Wireless Thermometer model 00782W

User Guide. Digital Shipping Scale S150

Owner's Manual. mycharge name and logo are registered trademarks of RFA Brands RFA Brands. All Rights Reserved. Patent Pending.

4-Hour. Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual

SFA275 USER MANUAL PLEASE READ THIS USER MANUAL COMPLETELY BEFORE OPERATING THIS UNIT AND RETAIN THIS BOOKLET FOR FUTURE REFERENCE

Air Curtain. Installation, Operating and Maintenance Instructions

Important Operating Instructions and Warranty Information On Your New Electronic AMSEC Safe

Installation Power Management Unit Battery Cables and Battery Harness

User s Manual. ClipperCreek, Inc. Innovative Infrastructure for Electric and Hybrid Vehicles. Model PCS-15

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

Power. On Your Terms.

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Please read and understand all precautions prior to use.

P OWER CUBE PLEASE READ BEFORE OPERATING THIS EQUIPMENT. Powerful Universal Portable Charger T M

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

2060F / 2062F / 2064F

OWNER S MANUAL Please read and understand all precautions prior to use.

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

Thermometer models 02023, 02028, 02029

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

WARRANTY POLICY. Grid-Tied Photovoltaic Inverters. Revision D. 2014, Solectria Renewables, LLC DOCIN

GC-1. Roof and Gutter De-Icing Control Installation and Operating Instructions FOR EXTERIOR INSTALLATION ONLY

COMMAND SERIES 410-L T L T T T L06R RS PRODUCT MANUAL

Ohaus ES Series Bench Scale

MQ4C-24/6485 WIRELESS INDOOR/OUTDOOR QUAD-COPTER

Instruction Manual for Globe Price Computing Scale Models GS30 and GS30T

SAVE THESE INSTRUCTIONS DANGER

Valor 1000W Series Instruction Manual. Serie Valor 1000W Manual de Instrucciones. Série Valor 1000W Guide de I utilisateur

OWNER S MANUAL CAMBRO CAMDUCTION COMPLETE HEAT CHARGER.

CRD600 Automatic Fitting Inserter

CRD610 Automatic Fitting Inserter

Water Jetter Units DU JT50 / DU JT100

FD Conveyor for FD 260 Tabber

Universal 8-Bay Charger. for AA/AAA/C/D/9 NiMH & NiCd Rechargeable Batteries. Owner's Manual

Operating Instructions

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

EAGL 1-Touch Laser Level

Adam Equipment QT SERIES. ADAM EQUIPMENT CO. LTD. pn Rev. D1, July 2002

Presoak & Tire/Engine Cleaner Systems (Air Pump) DU TC_A & DU PS_A

DeZURIK AFR3 Filter Regulator Used on Pneumatic Cylinder Actuators

AC / 65 W M PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

CLEAN ROOM DEVICES, LLC "WHERE TUBING AND FITTINGS COME TOGETHER"

Installation, Operating and Maintenance instructions for Hydro-Air pumps

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7515

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

User's Manual. Earth Ground Resistance Tester. Model Introduction

MFG. CO. INC. DODGE CITY, KANSAS (620) Electric Truck Auger. Owners Manual

Installation Manual. for Off Line Systems. INTELLIKEY is a trademark of INTELLIKEY Corporation GID 04/25/2003. Page 1

Operator Manual For use with WFCO ULTRA III Deckmount Converter WF-9800 Series (model number located on the cover of the unit)

Intelligent Electronic Safe

Digital Scale. Revision 1.0 August 17, Contents subject to change without notice.

Transcription:

PEDIATRIC SCALE Models 459-CH, 8432-CH and 8432-CHKGEU Owner s Manual CARDINAL SCALE MFG. CO. 8525-M178-O1 Rev F PO BOX 151 v WEBB CITY, MO 64870 Printed in USA 11/07 PH (417) 673-4631 v FAX (417) 673-5001 www.detectoscale.com Technical Support: Ph: 866-254-8261 v techsupport@cardet.com

8525-M178-O1 v 459-CH and 8432-CH Page 2

INTRODUCTION Thank you for purchasing our Detecto Pediatric Scale, Model 459-CH, 8432-CH or 8432- CHKGEU. Your scale was built with Detecto quality and reliability at our factory in Webb City, Missouri. This manual will guide you through setup and operation of your scale. Please read it thoroughly before attempting to operate your scale and keep it handy for future reference. SPECIFICATIONS 459-CH Capacity:.. 40 lb x 1/2 oz (17 1/2 kg x 10 g) 8432-CH* Capacity:.. 44 lb x.05 oz (20 kg x.02kg) Power Requirements:.... 6 AA size Alkaline, Ni-Cad or NiMH batteries (not included) OR an optional 100 to 240 VAC 50/60Hz 12 VDC 1A wall plug-in UL/CSA listed AC power supply. Operating Temperature:... 14 to 104 ºF (-10 to +40 ºC) 8432-CHKGEU** Capacity:.. 44 lb x.05 oz (20 kg x.02kg) Power Requirements:.... 6 C size Ni-Cad or NiMH batteries (not included) OR an optional 115 VAC 50/60Hz 12 VDC 300 ma wall plug-in UL/CSA listed power supply. (Also available for 230 VAC 50/60 Hz). Operating Temperature:... 14 to 104 ºF (-10 to +40 ºC) * For more information on the indicator used on the 8432-CH, refer to the 750 Weight Indicating Instrument Owner s Manual, 8555-M260-O1. ** For more information on the indicator used on the 8432-CHKGEU, refer to the 758CSV Weight Indicating Instrument Owner s Manual, 8555-M433-O1. FCC COMPLIANCE STATEMENT WARNING! The Model 8432-CH generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual, may cause interference to radio communications. It has been tested and found to comply with the limits for a Class A computing device pursuant to Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection against such interference when operated in a commercial environment. Operation of this equipment in a residential area is likely to cause interference in which case the user, at his own expense, will be required to take whatever measures may be required to correct the interference. You may find the booklet "How to Identify and Resolve Radio TV Interference Problems" prepared by the Federal Communications Commission helpful. It is available from the U.S. Government Printing Office, Washington, D.C. 20402, Stock No. 001-000-00315-4. All rights reserved. Reproduction or use, without express permission, of editorial or pictorial content, in any manner, is prohibited. No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this book, we assume no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein. All instructions and diagrams have been checked for accuracy and ease of application; however, success and safety in working with tools depend, to a great extent, upon the individual accuracy, skill and caution. For this reason, we are not able to guarantee the result of any procedure contained herein. Nor can we assume responsibility for damage to property or injury to persons engaging the procedures do so entirely at their own risk. 8525-M178-O1 v 459-CH and 8432-CH Page 1

ƒ ƒ ƒ ƒ ƒ ƒ CARE and CLEANING of SCALE DO NOT subject the platform (child seat) to sudden shocks. DO NOT expose scale to temperature extremes. DO NOT place scale in front of heating/cooling vents. DO NOT place scale in areas where it might be exposed to moisture. DO NOT submerge scale in water, pour or spray water directly on head assembly or indicator. DO NOT use an abrasive cleaner, acetone or other volatile solvents for cleaning head assembly, indicator, platform base or child seat. v v v v DO clean the head assembly, indicator or platform base with a damp soft cloth and mild non-abrasive detergent. DO clean the child seat with a soft cloth dampened with a mild detergent. The child seat may be removed and washed with a mild detergent. DO remove power on 8432-CH or 8432-CHKGEU before cleaning with a damp cloth. DO provide clean AC power and adequate protection against lightning damage for 8432-CH or 8432-CHKGEU. PRECAUTIONS Before using this instrument, read this manual and pay special attention to all "WARNING" symbols: IMPORTANT ELECTRICAL WARNING SERIAL NUMBER DATE OF PURCHASE PURCHASED FROM RETAIN THIS INFORMATION FOR FUTURE USE 8525-M178-O1 v 459-CH and 8432-CH Page 2

UNPACKING INSTRUCTIONS Carefully unpack scale components from the shipping carton. Examine the scale and baby seat for any damage that may have taken place during shipment. If you find evidence of shipping damage, the shipping company should be contacted at once. It is a good idea to keep the scale shipping carton and packing material for later use should storage or transport of the scale become necessary. COLUMN and HEAD ASSEMBLY CHILD SEAT SEAT GIMBAL PLATFORM BASE COLUMN and INDICATOR MOUNTING BRACKET ASSEMBLY 750 INDICATOR (8432-CH) or 758CSV INDICATOR (8432-CHKGEU) CHILD SEAT SEAT GIMBAL PLATFORM BASE 8525-M178-O1 v 459-CH and 8432-CH Page 3

CHILD SEAT INSTALLATION Before using the scale, it will be necessary to install the child seat. Follow the steps listed below to install the child seat. PARTS LIST TOOLS REQUIRED (1) Child Seat #1 Philips (1) Gimbal (4) 1/4-20 x 1/2 Truss head screws (4) #10-24 x 1/2 Truss head screws 1. Remove child seat and hardware kit (plastic bag with screws) from box. 2. Remove child seat gimbal from packing. 3. Remove mounting screws from plastic bag. 1/4-20 x 1/2 screws (gimbal to platform) #10-24 x 1/2 screws (seat to gimbal) 4. Determine which direction child seat is to face, left or right side of scale or forward (away from beam or indicator) and place gimbal on scale. 8525-M178-O1 v 459-CH and 8432-CH Page 4

CHILD SEAT INSTALLATION, Cont. 5. Align holes in gimbal with holes in scale platform and attach to scale platform with four 1/4-20 x 1/2" screws. 1/4-20 x 1/2 6. Tighten screws with Philips screw driver. 7. After gimbal is installed, position child seat in gimbal and attach with #10-24 x 1/2 screws (two screws on each side). #10-24 x 1/2 8. Periodically re-check screws for tightness. 9. Proceed to SETUP INSTRUCTIONS for your particular scale model 8525-M178-O1 v 459-CH and 8432-CH Page 5

459-CH SETUP INSTRUCTIONS Before using the scale, it must be balanced (zeroed). To zero the scale, perform the following: 1. Place the scale on a level, stable surface. 2. Referring to the illustration, move both poises to zero. 3. Locate the BALANCE SCREW on the left end of the beam and turn it in or out as required, until the BEAM POINTER is in the center of the opening in the TRIG LOOP. 4. The scale is now ready for operation. SMALL POISE LARGE POISE BEAM POINTER BALANCE SCREW TRIG LOOP 459-CH OPERATING INSTRUCTIONS 1. Place the scale on a level, stable surface. 2. With the child seat empty, move both poises to the Zero position. Be sure the BEAM POINTER is in the center of the opening in the TRIG LOOP. 3. Slide the LARGE POISE to the approximate weight of the child. I.E. If the child weighs approximately 25 pounds, slide the LARGE POISE to 25 pounds. 4. Lay the child being weighed in the center of the seat. This will distribute the weight evenly across the scale. 5. Slide the SMALL POISE to the middle of the beam (between 2 and 3 pounds). 6. Continue sliding the SMALL POISE until the BEAM POINTER is centered in the TRIG LOOP opening. 7. Read the SMALL POISE at the pointer and add to the weight from the LARGE POISE. I.E. If the LARGE POISE is at 25 pounds and the SMALL POISE is at 4 pounds, 6 ounces, the child weighs 29 pounds, 6 ounces. CAUTION! Do not leave the child unattended in the child seat. Failure to maintain continual control of the child can result in serious injuries should the child fall from the child seat. NOTE! The seat straps have been intentionally omitted! 8525-M178-O1 v 459-CH and 8432-CH Page 6

8432-CH SETUP INSTRUCTIONS AC Power Supply To operate the 8432-CH scale without batteries, connect the 12 VDC power supply s connector into the power jack on the lower back of the indicator and then plug the power supply into the proper electrical outlet. On models requiring 220 VAC, it is the customer s responsibility to obtain the correct power adapter plug. The scale is now ready for operation. NOTE! The AC power supply is also used to recharge the batteries in the indicator, when the scale is operated from Ni-Cad or NiMH batteries. Batteries Battery operation is a standard feature of the Detecto 750 indicator used on the scale, although the batteries are optional (not included). The indicator can be operated from 6 "AA" size Alkaline, Ni-Cad or NiMH batteries. The batteries are contained in a battery holder inside the indicator which is accessible by removing a panel on the back of the indicator. When using batteries, all 6 batteries must be of the same type. They must be all Alkaline, all Ni-Cad or all NiMH. In addition, DO NOT mix Ni-Cad or NiMH batteries. CAUTION! The indicator has circuitry that when used with the external power supply, recharges the Ni-Cad or NiMH batteries. Therefore, DO NOT connect a power supply to the indicator if using alkaline batteries. Battery Operation The scale will operate for up to 250 hours on new alkaline batteries or for up to 100 hours on fully charged Ni-Cad or NiMH batteries, depending on the condition of the batteries (from new to about 500 recharges). A bar graph on the display shows the battery capacity in 4 steps: 4 segments - the full battery capacity is available, 3 segments - the battery is at 75% of capacity, 2 segments - the battery is at 50% of capacity, 1 segment: - the battery is at 25% capacity. When the battery voltage drops too low for accurate weighing, the indicator will show "7< and then shut off. You will be unable to turn the indicator back on until the alkaline batteries have been replaced. If using Ni-Cad or NiMH batteries connect the AC power supply to the indicator and then plug it into the proper electrical outlet to begin charging the batteries. Battery Charging The AC power supply must be plugged into a proper electrical outlet and connected to the indicator for approximately 8 to 10 hours to fully recharge the batteries. Note that while the batteries are charging the indicator can still be operated and that charging the batteries for more than 10 hours will not damage them. 8525-M178-O1 v 459-CH and 8432-CH Page 7

8432-CH SETUP INSTRUCTIONS, Cont. Battery Installation/Replacement To install or remove batteries, perform the following steps: 1. Pull Spring Plunger Release and hold while removing indicator from bracket on scale. 2. Turn indicator so display is facing away from you (resting on keypad). 3. Locate the rectangular panel on back of indicator. 4. To install or replace batteries, first remove battery holder cover by pushing in on the tab and lifting it up. 5. If installing new batteries, proceed to step 6. If replacing the batteries, remove all 6 batteries from the battery holder and then proceed to step 6. 6. Install 6 new AA size batteries in the battery holder, noting polarity markings located in battery holder. 7. After placing all 6 batteries in battery holder, replace battery cover. 8. Make sure power supply is unplugged, and then turn indicator over (display facing up) and press ON/OFF key. 9. If display turns on, batteries have been installed correctly. If not, remove panel and check for one or more improperly positioned batteries. 10. Return indicator to scale bracket by placing screw heads on back of indicator into large end of slotted holes in bracket. Pull down to secure the indicator. Spring plunger will lock indicator to bracket. 11. Scale is now ready for operation. Push in and lift here + - - + + - - + + - - + Spring Plunger Release Battery Cover Power Supply Connector 8525-M178-O1 v 459-CH and 8432-CH Page 8

8432-CH OPERATING INSTRUCTIONS Basic Weighing 1. Place scale on a level, stable surface. 2. With the child seat empty, press ON/OFF key. 3. Press ZERO key to zero weight display. ZERO, [\ (STABLE) and lb or kg annunciators will turn on to show that scale is ready for use. 4. Lay child being weighed in center of seat. This will distribute the weight evenly across scale platform. 5. Read weight display. 6. Remove child from seat. Zero Weight Display 1. If weight display is not showing zero weight, press ZERO key. 2. Weight display will return to zero. ZERO, [\ (STABLE) and lb or kg annunciators will turn on to show a stable, center-of-zero weight condition. Zero Weight Display with Item on Scale 1. Place item (blanket or similar covering) on scale. 2. Weight display will show weight of item on scale. 3. Press ZERO key. 4. Weight display will return to zero. ZERO, [\ (STABLE) and lb or kg annunciators will turn on. The item s weight has been "zeroed off". 5. Proceed with weighing operation. Metric Conversion Press UNITS key to toggle between pounds and kilograms. The lb or kg annunciator will turn on to show which weighing unit is active. DO NOT press the keys on the keypad with pointed objects (pencils, pens, etc). Damage to the keypad resulting from this practice is NOT covered under warranty. CAUTION! Do not leave the child unattended in the child seat. Failure to maintain continual control of the child can result in serious injuries should the child fall from the child seat. NOTE! The seat straps have been intentionally omitted! 8525-M178-O1 v 459-CH and 8432-CH Page 9

8432-CHKGEU SETUP INSTRUCTIONS AC Power Supply To operate the 8432-CHKGEU scale without batteries, connect the 12 VDC power supply s connector into the power jack on the back of the indicator and then plug the power supply into the proper electrical outlet. On models requiring 220 VAC, it is the customer s responsibility to obtain the correct power adapter plug. The scale is now ready for operation. NOTE! The AC power supply is also used to recharge the batteries in the indicator, when the scale is operated from Ni-Cad or NiMH batteries. Batteries Battery operation is a standard feature of the Detecto 758CSV indicator used on the scale, although the batteries are optional (not included). The indicator can be operated from 6 "C" size Ni-Cad or NiMH batteries. The batteries are contained in a battery holder inside the indicator which is accessible by removing a panel on the back of the indicator. IMPORTANT! When using batteries, all 6 batteries must be the same type. They must be all Ni-Cad or all NiMH. DO NOT mix Ni-Cad or NiMH batteries. CAUTION! The indicator has circuitry that when used with the external power supply, recharges the Ni-Cad or NiMH batteries. Therefore, you CAN NOT use alkaline batteries in it. Battery Status When batteries are used, the indicator will show the battery status on power up. The display will show 32<<:> and then change to ò )) ò, where YY indicates the remaining battery voltage expressed as a percentage (%) of the total battery voltage Low Battery Indicator The "$a' (low battery) annunciator turns ON to indicate the batteries will soon need to be recharged. Normal operation will continue until the battery voltage drops to too low for accurate weighing. When this occurs, the indicator will automatically turn itself off and you will be unable to turn it back on. Connect the AC power supply to the indicator and then plug it into the proper electrical outlet to begin charging the batteries. Battery Charging The AC power supply must be plugged into a proper electrical outlet and connected to the indicator for approximately 6 hours to fully recharge the batteries. Note that while the batteries are charging the indicator can still be operated and that charging the batteries for more than 6 hours will not damage them. 8525-M178-O1 v 459-CH and 8432-CH Page 10

8432-CHKGEU SETUP INSTRUCTIONS, Cont. Battery Installation/Replacement To install or remove batteries, perform the following steps: 1. Push latch release down flush with back of indicator and hold while removing indicator from bracket on scale. Latch Release 2. Turn indicator so display is facing away from you (resting on keypad). 3. Locate rectangular panel on back of indicator and remove thumb screw. 12 VDC 4. To install or replace batteries, remove panel (lift straight up and slide out) exposing battery holder. Thumb Screw 5. If installing new batteries, proceed to step 6. If replacing the batteries, remove all 6 batteries from the battery holder and then proceed to step 6. 6. Install 6 new C size batteries in the battery holder, noting polarity markings located in battery holder. 7. After placing all 6 batteries in battery holder, replace panel on back of indicator (slide tab into slot on rear panel) and install thumb screw. 8. Make sure power supply is unplugged, and then turn indicator over (display facing up) and press ON/OFF key. Battery Door 9. If display turns on, the batteries have been installed correctly. If not, remove panel and check for one or more improperly positioned batteries. ON/OFF key 10. Return indicator to scale bracket by pushing latch release down flush with back of indicator and holding. Next, place large end of slotted holes in bracket over screw heads on back of indicator. Pull down to secure indicator. Release latch release to lock indicator to bracket. 11. Scale is now ready for operation. + + 8525-M178-O1 v 459-CH and 8432-CH Page 11

8432-CHKGEU OPERATING INSTRUCTIONS Basic Weighing 1. Place scale on a level, stable surface. 2. With the child seat empty, press ON/OFF key. 3. Press ZERO key to zero weight display. ZERO, [\ (STABLE) and kg annunciators will turn on to show that scale is ready for use. 4. Lay child being weighed in center of seat. This will distribute the weight evenly across scale platform. 5. Read weight display. 6. Remove child from seat. ON/OFF key ZERO key Zero Weight Display 1. If weight display is not showing zero weight, press ZERO key. 2. Weight display will return to zero. ZERO, [\ (STABLE) and kg annunciators will turn on to show a stable, center-of-zero weight condition. Zero Weight Display with Item on Scale 1. Place item (blanket or similar covering) on scale. 2. Weight display will show weight of item on scale. 3. Press ZERO key. 4. Weight display will return to zero. ZERO, [\ (STABLE) and kg annunciators will turn on. The item s weight has been "zeroed off". 5. Proceed with weighing operation. DO NOT press the keys on the keypad with pointed objects (pencils, pens, etc). Damage to the keypad resulting from this practice is NOT covered under warranty. CAUTION! Do not leave the child unattended in the child seat. Failure to maintain continual control of the child can result in serious injuries should the child fall from the child seat. NOTE! The seat straps have been intentionally omitted! 8525-M178-O1 v 459-CH and 8432-CH Page 12

ERROR CODES The indicators used on the 8423-CH and 8423-CHKGEU scale are equipped with a diagnostic software program that tests various portions of the instrument s circuitry and verifies proper operation. Should a problem be detected, an error or status message will be displayed alerting the operator to the condition. The following lists these errors and status displays and their meaning. DISPLAY A::A A$A A<:"A A(1+A ".3 4::a ::"a :: ::a a::a $% $ MEANING General error, invalid keypad entry was attempted. Attempting to display a negative number greater than 9,999 or a positive number greater than 99,999 Indicates an attempt to zero a weight outside scale zero range. (See Four Percent Zero Tracking Range Limit). Motion is present when indicator is attempting to perform one of the following operations: Power Up Zero or Zero Weight Display Indicates calibration is necessary. These error messages are displayed on both the 8432-CH and the 8432-CHKGEU. Consult your scale service representative. These error messages are ONLY displayed on the 8432-CHKGEU. Consult your scale service representative. Scale weight exceeds scale capacity Displayed to indicate indicator is turning off. PROBLEM Display does not turn on Incorrect weight displayed Indicator will not display weight BEFORE YOU CALL FOR SERVICE POSSIBLE SOLUTIONS AC Operation: v v v v Is AC power supply fully inserted into wall receptacle? Check wall receptacle for proper AC power. Try another electrical appliance in same receptacle, does it work? Check circuit breaker. Has there been power failure? Battery operation: v v Check if batteries are installed and correctly. Are batteries discharged? If Ni-Cad or NiMH, connect 12 VDC power supply's connector into power jack on back of indicator and then plug power supply into proper electrical outlet to operate indicator and recharge batteries. On 8432-CH only, if using Alkaline batteries, remove old batteries and replace with new ones. Insure child seat isn't touching an adjacent object. Have proper operating instructions been followed? Refer to Error and Status Displays section. 8525-M178-O1 v 459-CH and 8432-CH Page 13

This page intentionally left blank. 8525-M178-O1 v 459-CH and 8432-CH Page 14

This page intentionally left blank. 8525-M178-O1 v 459-CH and 8432-CH Page 15

STATEMENT OF LIMITED WARRANTY Detecto Scale warrants its equipment to be free from defects in material and workmanship as follows: Detecto warrants to the original purchaser only that it will repair or replace any part of equipment which is defective in material or workmanship for a period of one (1) year from date of shipment. Detecto shall be the sole judge of what constitutes a defect. During the first ninety (90) days Detecto may choose to supply all necessary replacement parts and service during normal weekday working hours at no charge to the buyer. After the first ninety (90) days Detecto will supply parts and service at the job site provided the owner agrees to pay the Dealer for all travel time, including mileage and test equipment, as well as any expenses incurred over the direct labor of the technician at the job site. This limited warranty honors only labor performed by Detecto authorized dealers. This warranty does not apply to peripheral equipment not manufactured by Detecto; this equipment will be covered by certain manufacturer s warranty only. This warranty does not include replacement of expendable or consumable parts. This does not apply to any item which has deteriorated or damaged due to wear, accident, misuse, abuse, improper line voltage, overloading, theft, lightning, fire, water or acts of God, or due to extended storage or exposure while in purchaser s possession. This warranty does not apply to maintenance service. Purchased parts will have a ninety (90) day repair or replacement warranty only. Detecto may require components be returned to the factory; they must be properly packed and shipping charges prepaid. A return authorization number must be obtained for all returns and marked on the outside of all returned packages. Detecto accepts no responsibility for loss or damage in transit. 8525-M178-O1 v 459-CH and 8432-CH Page 16

STATEMENT OF LIMITED WARRANTY Conditions Which Void Limited Warranty This warranty shall not apply to equipment which: A.) Has been tampered with, defaced, mishandled or have had repairs and modifications not authorized by Detecto. B.) Has had serial number altered, defaced, or removed. C.) Has not been grounded according to Detecto s recommended procedure. Freight Carrier Damage Claims for equipment damaged in transit must be referred to the freight carrier in accordance with freight carrier regulations. This warranty sets forth the extent of our liability for breach of any warranty or deficiency in connection with the sale or use of the product. Detecto will not be liable for consequential damages of any nature, including but not limited to, loss of profit, delays or expenses, whether based on tort or contract. Detecto reserves the right to incorporate improvements in material and design without notice and is not obligated to incorporate improvements in equipment previously manufactured. The foregoing is in lieu of all other warranties, express or implied including any warranty that extends beyond the description of the product including any warranty of merchantability or fitness for a particular purpose. This warranty covers only those Detecto products installed in the forty-eight (48) contiguous continental United States. Ph. (800) 641-2008 E-mail: detecto@cardet.com 203 E. Daugherty Webb City, MO 64870 02/06 Printed in USA D268-WARRANTY-DET 8525-M178-O1 v 459-CH and 8432-CH Page 17

8525-M178-O1 v 459-CH and 8432-CH Page 18